Home

Colosseum user manual

image

Contents

1. johansson user Colosseum manual 8500D No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron can not be held liable for any damages resulting from the use of this product Specifications are subjectto change without notice 11 11 O Unitron Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 email sales johansson be www johansson be www unitrongroup com CONTENTS 1 INTRODUCTION MISE ide ibi bois a a dae 4 package CONTENTS NOS 6 HARDWARE INSTALLATION eenen 6 WEBGUI minimal system requirements tnter tenens 8 logging into the deviC tnnt tnnt nnns 8 general configuration nennen nnne nnne tnnt aaa 10 A SINUN 10 xd t 11 5 AAA a 11 DERIT IE Do REP 12 HOAS E S LG IE ii ana tap ER a cae cad 12 connguration OT tie OU ii 13 CODI ALO oi eeen eener 16 configuration of the MPEG setting nnns 20 TECHNICAL SPECIFICATIONS eneen 21 CONDITIONS OF WARRANTY eenen 22 UHF FREQUENCY TABLE eene 23 POWER CONVERSION 24 1 INTRODUCTION SAFETY INSTRUCTIONS Read these instructions carefully before connecti
2. a correct functioning of the interface The webGUI will indicate this with a warning message This message will be shown every time you browse to another menu item Please install one of the above browsers to avoid this LOGGING IN TO THE DEVICE Connect the module to your PC The module will obtain an IP address from your PC For this operation to work it is important that the PC is NOT set with a manual IP address Set the adapter to obtain an automatic IP address as explained in the following proce dure for Microsoft Windows 79 Navigate to the Control Panel Start Control Panel Enter the Network and Sharing Center and go to the Adapter Settings Not connected x 9 Bluetooth Device Personal Area Ks Bluetooth Network Connection iv Connect using GP Realtek PCle GBE Family Controller This connection uses the following items 3 Client for Microsoft Networks Shrew Soft Lightweight Filter Virtual PC Network Filter Driver 00 Packet Scheduler J File and Printer Sharing for Microsoft Networks LL 4 Transmission Control Protocol Intemet Protocol The default Disable Wireless Network Connection unitrongroup intra Status Diagnose Bridge Connections Create Shortcut Delete Rename Properties Atheros AR9285 802 11b g n WiFi R Wireless Network Connection 2 x Not connected Microsoft Virtual WiFi Miniport
3. multiplexes adjacent and only the frequency of the first needs to be configured the others will automatically be set according to this frequency and the bandwidth e Mux The multiplex number 1 to 4 e Frequency kHz multiplex frequency in the VHF UHF range 47000 to 830000 kHz When entering a frequency outside this frequency range an error will be shown to the user E a Level dBm Constellation Code Rate Guard interval sewn 5 GE p 825 EE 634000 132 642000 E 132 Bandwidth Spectral inversion Level dBm signal output level range 40 to 25 dBm Constellation o OPSK o 16 0AM o 64 0AM Code Rate o 1 2 o 2 3 o 9 4 o 4 5 o 5 6 o 7 8 Guard interval o 1 32 o 1 16 o 1 8 o 1 4 Status o ON the multiplex is active o OFF the multiplex is not active Bandwidth 6 7 8 MHz Spectral inversion o ON the frequency spectrum will be inverted o OFF no frequency inversion Press APPLY to save the settings to the module 18 The TSID amp LCN parameters are used to setup the logical channel numbering chan nel sequence on the TV TSID amp LCN amp r PA TSID L W LON 1 23 LCN2 2 LCN3 11 LCN4 26 LCN5 17 LONG 18 LON 7 19 LCN8 20 i 1 1 1 1 1 858 e TSID Transport Stream Identifier e LCN Logical Channel Number Navi
4. qualified personnel R Dispose according your local authority s recycling processes PACKAGE CONTENTS Be sure all items listed below are included 1 Colosseum Ref 8500D 1 CAT6 ethernet cable 1 power cord 1 user manual 2 HARDWARE INSTALLATION The unit can be placed on a table 1 or mounted to the wall 2 For wall mounting drill two holes 23 cm apart and insert two screws min length from wall to screw head is 12 mm and diameter of screw head is max 11 5 The unit can be mounted with its connectors up or down but preferrably with the con nectors down After positioning of the unit wall or table connect the cables The unit is preconfigured for ASTRA 19 2 Connect the cables as shown in the picture 0000000 nk 00 0 ASTRA 19 2 Vertical Low ASTRA 19 2 Horizontal Low ASTRA 19 2 Vertical High ASTRA 19 2 Horizontal High 00000 Power cord NOTES e Connectthe 4 cables of a Quad Quattro LNB to prevent alarm messages Some LNB s require a lot of power to work properly The unit is able to deliver this power only when the 4 polarities are connected e Do not change the bridges or load resistors 3 WEBGUI MINIMAL SYSTEM REQUIREMENTS The WebGUI is supported by the following web browsers and newer versions of these browsers e Chrome 4 e Safari 3 1 e Firefox 3 6 Explorer 8 Opera 10 6 When using a different browser we cannot guarantee
5. 060 E VOX CH 12061 Channel 21 12080 E n tv 12090 EI Channel 21 12095 The status of the tuner is shown e Status o Green tuner locked o Red tuner unlocked e Level input signal level dBm e BER Bit Error Rate e SNR Signal to Noise Ratio dB The table Available services shows all the services found in the transponder e Type Type of data TV service J radio service ki locked service encoded a unlocked service decoded e Name Service name e SID Service Identifier unique ID for a service 15 CONFIGURATION OF THE OUTPUT Navigate to the MUX SETTINGS to configure the COFDM output parameters johansson Language en Alam O DMH web interface 1 3 0 Release 53020 ProQuad OPSK COFDM Configuration j E Mux rom Level dBm Constellation Code Rate Guard interval kHz DVB S2 inputs E DVB T outputs 6180000 4 25 64 626000 25 1 2 MUX settings 3 634000 25 4 642000 4 25 Service assignment MPEG settings Bandwidth Spectral inversion 8 MHz OFF y Apply TSID amp LCN MUX 1 MUX2 MUX3 MUX 4 TSID TSID LCN 1 LCN 1 LCN 2 LCN 2 LCN 3 LCN 3 LCN 4 LCN 4 LCN 5 LCN 5 LCN 6 LCN 6 LCN 7 LCN 7 LCN 8 LCN 8 Apply TSID LCN 1 LCN 2 LCN 3 LCN 4 LCN 5 LCN 6 LCN 7 LCN 8 TSID LCN 1 LCN 2 LCN 3 LCN 4 LCN 5 LCN 6 LCN 7 LCN 8 999959194 9991931 939993391 The 4
6. 57 33 33 63 32 57 33 45 24 salesQjohansson be www johansson be
7. Double click on Internet Protocol Version 4 TCP IPv4 to enter the IP settings of your adapter You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings 6 Obtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Preferred DNS server Alternate DNS server Validate settings upon exit Make sure the Obtain an IP address automatically checkbox is selected Click OKto save the settings 10 Open your network browser and surf to the name of the module The name of the first module is mod the name of the second module is mod2 You will now log in to the module After logging in the Summary window appears status johansson Language gt Alarm O 1 LED DVB T outputs MPEG settings Active services Name z 3 SPORT1 ZDF HD n tv 3sat DKULTUR Das Erste HD zdf neo DRadio Wissen SUPER RTL arte HD KIKA zdf kultur RTL Television RTL2 On this screen you see all the services streamed by this module The type of module the status and the language are visible on every screen In the picture above the status LED is green indicating that there are no alarms The alarm status is shown when you move over the status LED with your m
8. g free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it See note below If during this period of warranty the product proves defective under normal use due to defective materials or workmanship Unitron N V at its sole option will repair or replace the product Return the product to your local dealer for reparation THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM Misuse or use of the product out of its specifications e Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters e Installation in a defect system e External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF e Production date or serial number on the product is illegible altered deleted or removed e The product has been opened or repaired by a non authorised person NOTE Date of production is MMYY format example 0411 April 2011 For the serial number barcodes the date corresponds to the 4 first numbers TV band Freguency MHz 23 24 ua uossupyol x uossupyol ua uossupyol N UN TRAN www unitrongroup com UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32
9. gate to the SERVICE ASSIGNMENT menu to setup the TV and radio services at the output johansson DMH web interface 1 3 0 Release Language en Alam O 53020 ProQuad QPSK COFDM CO comm vc COI DVB S2 inputs DVB T outputs MUX settings Service assignment MPEG settings LCN Name 1 2 SPORT 2 gt ZDF n n tv 4 gt 2 DLF 5 ES LN Bitrate GD 19 32 Mbps 0008080080 ES ES ES E ES Press the GY button to add a new service A list of available services from all 4 tuners will appear on the screen Click on the service to be added and wait until the service is loaded into the list The list will be refreshed and the added service will appear NOTES LCN Logical Channel Number A logical channel number also known as virtual channel is a channel designation which differs from that of the actual channel or range of frequencies on which the signal travels Name Service name SID Service Identifier On o Check to enable the service at the output o Uncheck to disable the service CAM Check to pass the service through the CAM card Encoded services will automatically pass through the CAM Icons GQ add a new program to the list of services update the current service this icon will become active if some setting has changed delete the service from the list pressing this icon will remove the program permanently you can add it again The bitra
10. input e g V low or ASTRA 19 2 V Low Voltage The LNB voltage to select the polarization o 13V Vertical polarization o 18V Horizontal polarization Tone LNB tone to select low high band o ON high band o OFF low band DiSEqC control of a DiSEgC switch A B C D Band Satellite band o Ku band common in Europe o C band mostly used in the USA Ext Voltage Add 1V to the LNB voltage to compensate the cable losses for long coaxial cables Press APPLYto confirm the parameters Go to the TUNER menu to configure the tuner frequency The modules have 4 independent tuners which can be assigned to every input thanks to a built in multiswitch Tuner 1 Settings o Input H high Frequency MHz 1 2188 Baud Rate kBaud 27500 e Input One of the 4 labels configured in the previous step This selects the satellite input e Frequency Transponder frequency e Baud rate kBaud Press APPLY to confirm the parameters The module will now set the tuner to this frequency Wait until the correct parameters are loaded When the tuner is able to lock on the frequency the list of services from this tran sponder will be shown Lock Level 3498 BER QU 10 SNR GN 1448 Available services Type Name SID RTL Television 12003 M RTL HH SH 12004 EI RTL HB NDS 12005 RTLFS 12006 RTL2 12020 A RTL Living 12030 v SUPER RTL 12040 El SUPER RTL CH 12041 EI VOX 12
11. ng the unit A To prevent fire short circuit or shock hazard Donot expose the unit to rain or moisture Install the unit in a dry location without infiltration or condensation of water Donotexpose it to dripping or splashing Do not place objects filled with liquids such as vases on the apparatus f any liquid should accidentally fall into the cabinet disconnect the power plug A To avoid any risk of overheating Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation Donot place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes The unit must not be exposed to any source of heat sun heater Donot place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climats not in tropical climates Respect the minimum and maximum temperature specifications N To avoid any risk of electrical shocks Connect apparatus only to socket with protective earth connection The mains plug shall remain readily operable Pull out power plug to make the different connections of cables To avoid electrical shock do not open the housing of adapter K Maintenance A Only use a dry soft cloth to clean the cabinet N Do not use solvent N For repairing and servicing refer to
12. ohansson Language en Alam O DMH web interface 1 3 0 Release 53020 ProQuad QPSK COFDM Reset to factory defaults has been aborted Configuration Global Factory reset Firmware upgrade Module restart DVB S2 inputs DVB T outputs MPEG settings 11 12 FIRMWARE UPGRADE To upgrade the firmware of the device click the Firmware upgrade menu item johansson Language Jen Alam O DMH web interface 1 3 0 Release 5302Q ProQuad QPSK COFDM c File Browse Configuration Global Factory reset Firmware upgrade Module restart DVB S2 inputs DVB T outputs MPEG settings Click on the BROWSE button and open the upgrade file Click UPLOAD to send the file to the device this will install the new firmware on the device MODULE RESTART Press this menu item to restart the module johansson Language en Alam O DMH web interface 1 3 0 Release 53020 ProQuad QPSK COFDM Restart of the module has been aborted Configuration Global Factory reset Firmware upgrade Module restart DVB S2 inputs DVB T outputs MPEG settings CONFIGURATION OF THE INPUT Go to the LNB Settings menu to configure the 4 LNB inputs johansson Language en Alarm O Band Ext voltage i 13 E co lt KN A KR lt Input Sequence number of the input also indicated on the front of the actual module Label custom label for each
13. ouse GENERAL CONFIGURATION ABOUT The about tab gives some basic information about the device Here you can find the serial number the software version and release date These are useful to check If you have the latest software version installed on your device New versions can be found on the website If you experience serious problems you can download a troubleshoot information file Save this file and mail it to us for analysis I9 johansson Language en Alam O DMH web interface 1 3 0 Release 5302Q ProQuad QPSK COFDM Serial number SN1145000000779 Release version 1 3 0 Release Release date Oct 27 2011 08 22 10 Troubleshoot information is available here GLOBAL Here you can configure the hostname of the module This name can be used to ac cess the module by simply typing it into your browser as the address and surf to it This is more convenient than using the IP address johansson Language gt Alarm O DMH web interface 1 3 0 Release 53020 ProQuad QPSK COFDM Configuration E Host name MOD1 Global IP address 169 254 197 240 Factory reset Firmware upgrade Apply Module restart DVB S2 inputs DVB T outputs MPEG settings Just enter http hostname into your favorite browser not case sensitive and press enter DMH web interface O mod1 FACTORY RESET All settings can be resetto default by means of a factory reset j
14. te bar shows the current bitrate of the selected multiplex The number of services per multiplex is restricted to 8 Depending on the model the module disposes of 4 multiplexes each capable of transporting 8 programs The maximum bitrate per MUX is 32 Mbps depending on the modulation parameters It is however advisable to keep a buffer of 4 Mbps to prevent possible overflow bitrate of services can fluctuate in time Select another multiplex by clicking on the tabs on top of the page 20 CONFIGURATION OF THE MPEG SETTINGS This menu item is only visible with modules having a DVB S 2 input johansson Language en Alam 5302Q ProQuad QPSK COFDM Forward EPG tables CAS forwarding gt Block others gt M PID share Apply Forward EPG tables Forward Electronic Program Guide tables to the TV s CAS forwarding Forward the Control Access System tables CAT EMM ECM to descramble the programs with a set top box o CAT Conditional Access Table o EMM Entitlement Management Message o ECM Entitlement Control Message e Block others Block private data e PID share Enable sharing of the PES PCR and ECM 3 TECHNICAL SPECIFICATIONS wwr 8 tuners 8 transponders 68 to 83 dBuV adjustable RF 20 x female CONNECTORS Management 2 x RJ 45 DC banana sockets 21 22 4 CONDITIONS OF WARRANTY PERIOD OF WARRANTY Unitron N V warrants the product as bein