Home
RecoRdeRs and data acquisition
Contents
1. pe m E S5 3g pum ox T cc C m Combustion Safety and Efficiency Process Valves sJouJuJeJboJg SJO3e2Ipu e316Iq pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I ot Y gt a LI Un oO S Adualdyjy pue Ayajes uonsnquJo S AJLA SS2920Jd L 240 RECORDERS CHART Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 DR4300 10 Circular Chart Recorder Features One or Two Pen Models Accuracy 0 35 Span Field Configurable Fully configurable via DIP switches Set chart range and speed to meet your needs Support for Thermocouple Types J K R S T 100Q RTDs plus 0 20 or 4 20 mA 0 20 or 0 50 mV 0 5 and 1 5 VDC T Standard With Digital Display Built In Self Test Thermocouple Burnout Protection If a thermocouple fails the pen is driven upscale to safely shut down your process Can be field adjusted as downscale failsafe FM Approved Limit Control Models Optional high or low manual reset PV limit alarm Adjustable will energize a relay to activate an alarm or shut down a process Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Honeywell UL GB CE Search www lesman com for DR4300 Circular Gol Display Models Also Include Improved Accuracy to 0 10 span 24 V
2. 7 7o included w unit_ 328 00 546 00 Export to flash memory in CSV format is standard GR feature SINIS Import data from any TrendView or X Series recorder Communicate real time via Ethernet Archive data on a single integral database schedule downloads of recorder data Graph plot and export data across any recorder pen Remotely configure recorders TrendViewer View graph print data from a flash memory stick TrendManager Pro TMP Using a database avoids issues of imported data being a collection of oddly named files Instead imported data is saved in an archival database for easy retrieval A search tool identifies archived data by batch field ID or date and time fetches and displays it in either graphical or tabular nu merical format Chart graph tools zoom in or out a cursor displays digital values There are navigation buttons for major functions like import print search and custom labeling JpU EIA mA HI Shor irh C r ppi a e 1 Siik t a 9 icis eu Data from different recorders can reside on the same chart E eet LE ee mare mi r AOA CENA ae Chart templates make it easy to retrieve recurring data like last Xn o onna Alm ON Takt hour s last shift s yesterday s or last week s data Exports data in A oe Waa eame itg csv spreadsheet format cies DR ace tetra TrendServer Pro TSP TSP does everything TMP does butis fully das 5 Sees Menon
3. Extended Security System ESS provides extended features includ ing entry of unique User IDs and associated passwords time out of password entry password expiration and traceability of user actions ESS is compatible with the requirements of 21CFR part 11 Security Tag Wire seal provision that provides added security to seal the front door and rear wiring when using optional rear cover to prevent undetected entry to these areas of the recorder Other Features 24VAC DC or 48VDC Power Supply 20 to 50 VDC 20 to 30VAC 24VDC Transmitter Loop Power Minitrend supplies up to 200mA not DC version Multitrend supplies up to 1 Amp Enclosure Rating Standard NEMA 3 IP55 type front face protection NEMA 4X IP66 available as an option Approvals CSA UL and FM CL1 Div 2 approvals CE conformity Solids Flow and Motion Controllers and Programmers Digital Indicators ZO E S5 Og pum ox v cc C em Combustion Safety and Efficiency Process Valves UOHO pue Mo 4 SP OS sJouJuJeJboJdg pue SJa O43u0 D 10 eD1P Uy Je3161Q CO ot Y gt a Ke LI N oO S pue siapsoday Ad ualdyjy pue Ayajes uonsnquJo S AJLA SSa20Jd PAPERLESS RECORDERS Illinois Indiana Missouri and lowa Ly Fax 630 595 2386 Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument C
4. PAPERLESS RECORDERS 253 T V01 2015 Fax 262 923 1797 Math Algorithms All analog input channels have a math expression block Fully programmable 100 characterfreeform math expression per pen Math calculations available one per input plus 16 extra pens Scripting maths includes conditions and multiline scripting in pen maths expressions Allow functions permanent variables and constants HealthWatch Maintenance Recorder keeps track of Birth Date Power cycles Time On Time Off Hi Lo CJCvalue Hardware Firmware updates Calibration Dates and Backlight operation Custom Screens Provides recorder the capability to accept custom screen designs from the Screen Designer software Depending on the size of the screen designs up to 10 screens can be loaded into the recorder memory OPCServer OPC UA compliant Totalizers and up to 96 pens can be transmit ted via OPC server max poll rate 1 s Available 2014 Approvals CSA CSA22 2 No 1010 1 2004 Certificate Number L211230 UL ANSI UL61010 1 2004 File 201698 FM Class 1 Division 2 Physical Parameters Enclosure Bezel Zinc plated steel case with high impact resistant polycar bonate bezel scratch resistant lens NEMA 3 IP55 protection rating standard Optional NEMA 4 IP66 Front face only Mounting Panel Unlimited mounting angle For best display view the angle should not exceed 65 from left or right 65 looking down and 40 looking up Mounting adjustable for panel thickn
5. Transmitter Supply Voltage 22 26 VDC at input terminal 1 2 watts Case NEMA 3 rated Molded foamed Noryl with gasketed door Stainless steel or NEMAAX available Approval Bodies CSA and FM approved Temperature Range Ambient 58 131 F Extreme 32 131 F Recorder Configurable Parameters Recorder Time 0 23 Hrs 1 59 Min Date 1 12 Mo 1 31 Day 4 Digit Year Chart Speed 8 hours 24 hours 7 days or selectable in 6 744 hours per revolution Continue Yes No Beyond 360 Rotation Chart Name Up to six characters Header Yes No Pen 1 Same for Pens 2 4 Pen Disable or enable Pen Input Input 1 PV Output or SP Chart 1 High Low Range Values 999 0 to 9999 Major Minor Chart Divisions 2 to 10 Units Up to 5 characters Algorithm Input 2 3 and 4 Disable or Enable Relative Humidity Yes or No Atmospheric Pressure 590 800 mmHg RH Comp Deviation None Setpoint or Channel 1 Deviation Setpoint 999 0 to 9999 Input 1 Same for Pens 2 4 Except for RF Decimal Place None 1 2 3 One decimal place for nonlinear inputs Unit Type F C or engineering units Transmitter Characterization All nonlinear input types High Low Range Input Compensation 999 0 to 9999 Filter 1 0 to 120 seconds Sensor Break Protection None Upscale or Downscale Emissivity 0 01 to 1 00 Input Actuations PV Input B 105 to 3300 E 454 to 1832 E low 200 to 1100 J 0 to 1600 J low 20 to 770 41 to 1
6. RECORDERS AND DATA ACQUISITION contents 237 l Save our natural resources Save storage space Save time Save money Fit a truckload of data on a USB stick Sound good Then take a look at the new multipoint video recorders from Honeywell We can also help you tie your instrumen tation to your plant network Lesman is the authorized stocking representative for Honeywell Sensing and Controls instrumentation for Northern Illinois Northwest Indiana Eastern lowa and the pulp and paper industries of Wisconsin and Michigan s upper peninsula If you see a Block L on a product model number we stock it so it s available to ship to you the same day Solids Flow and Motion E Lesman Online Pressure Temperature Level Flow Analytical Products File Edit View Favorites Tools Help Prices See Startat Page Controllers and Programmers Circular Chart Recorders Honeywell DR4300 10 Circular Chart Recorders 928 00 240 Honeywell DR4500 12 Classic Circular Chart Recorder 1653 00 242 Honeywell DR4500 12 Truline Circular Chart Recorders 1912 00 244 Z o Paperless Video Display Recorders Honeywell eZtrend GR 5 Display Paperless Recorder 1803 00 248 Honeywell Minitrend GR 5 5 Display Web Ready Paperless Recorder 2730 00 250 i Honeywell Multitrend GR 12 1 Display High Performance Web Enabled Paperless Recorder with Enhanced Data Storage 4001 00 250 Stripchart Recorders Honeywell DPR180 7 D
7. Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com DR4500 Classic 12 Circular Chart Recorder New Features Auxiliary Output e Mass Flow and BTU Calculation 2Loops of Control Improved Setpoint Programming Decimal Point Scaling on Charts Works with RS 485 to Ethernet bridge DR4500 Classic The Benchmark for 12 Circular Chart Recorders An Instant Classic Honeywell s DR4500 Classic 12 circular chart recorder is ideal for ap plications in food pharmaceuticals environmental testing and metal working where measured variables must be documented on a single chart and retained to meet industry requirements With a Unique Lineup of Features Extremeaccuracy Typicallylessthan X 1 Ffortheusablethermocouple ranges meets the MIL requirement for type T and Pt100Q RTD 0 1 or better for voltage ranges Universal inputs Accepts all thermocouples Types B E J K N R S T W5W26 RTDs Pt100Q or Pt500Q relative humidity 0 100990 volt age current 0 10 or 10 50 mV 0 5 or 0 10V 4 20mA Easy setup English prompts and menus walk you through configura tion Simplifies setup and reduces risk of configuration errors Field configurable Chart ranges can be set and reset in the field simply by inputting on the keyboard Standard charts Usesa standard 12 charttorecord process variables chartrangesand speedsare keyboard selectable Chart speeds vary from 1 to 73
8. or Time Proportional Duplex 2 SPST electromechanical relays N O or N C contacts selectable CurrentProportional 21mADC max into a grounded or non grounded load of 0 1000Q 4 20 mA output range 0 5 full scale accuracy Position Proportional 2 SPST relays run motor with 100 10000 slidewire Current Time Proportional For heat cool applications 4 20 mA signal fed into a grounded load of 0 1000Q operating over 5096 10096 range 0 596 full scale accuracy SPST electromechanicalrelayfortime 5A 120VAC 2 5A 240 VAC resistive and 50 VA 120 240 VAC inductive contact ratings Limit Control FM approved Latching relay is de energized when PV goes aboveorbelow a preset setpoint Alarm indicator lights when relay is latched Resets through a key on the front of the recorder or an external switch See next page for Model Selection Guide Solids Flow and Motion Controllers and Programmers Digital Indicators pe Su S5 Og pum ox vm cc C em Combustion Safety and Efficiency Process Valves sJouJuJeJboJd SJO3e2Ipu e316Iq pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I ot D gt a Ke N c o S Ad ualdyjy pue Ayajes uonsnquJo S AJLA SSa20Jd CHART L 246 RECORDERS Fax 630 595 2386 DR4500 Truline 12 Circular Chart Recorder Ordering Instructions Make one selection from each table section Check the availability column to be sure that the unit you need is
9. 200 ms for all alarms 4 or 8 relay contacts SPDT 3A 240VAC 3A 24VAC DC 0 2A 240VDC non inductive internally suppressed 8 I O or 16 I O 1A 24VDC non inductive internally suppressed Activation Fully programmable internal alarm levels Assign able to any relay or discrete output Digital Input Output 8 O or 16 I O All channels may be selected freely as either digital inputs or outputs 4 relay outputs all four channels are relay outputs only 8 relays 2 DI card Two outputs can be configured for use as digitalinputs Ifthe 2 Digital inputs are used only 6 relay outputs are available Analog Outputs Retransmission 2 or 4 retransmission outputs available a pen drives each output Analog inputs totalized values or any mathematical result can be retransmitted Update Rate 250 msec all channels Accuracy 0 1 0 500Q load 0 25 500Q 1K load Type 0 20 4 20 mA Maximum Load Resistance 1000 Resolution 0 002 Isolation 300VAC Transmitter Power Mini 200 mA 24 VDC 3 VDC Multi 1A 24 VDC Extended Security System ESS Compliant with 21 CFR Part 11 Includes features for entry of unique user IDs and passwords timeout on inactivity 1 to 10 min password expiration 1 to 365 days up to 50 users password re entry lock out for incorrect entry of password more than 3 times no reuse of passwords programmable 4 to 12 times traceability by user name Totalizer Sterilization One totalizer per input Totalizer
10. 41 to 1815 Pt100Q 300 to 900 184 to 482 Pt100Q low 130 to 392 90 to 200 0 20 4 20 mADC 0 10 0 100 and 0 200 mVDC 0 1 0 2 0 5 1 5 and 0 10 VDC RTD IEC 0 00385 Linear 5d uo e LLY NORN APLE DR4300 Recorder Supplies TOCK In Stock at Lesman DLL Box of 100 Charts 32 34 660 24 Hour 661 7 Day 85 190 RTD asit 24001660 047 0 100 C or Lin 24001660 001 0 300 F Type J 24001660 002 0 600mV 4 20 mA Lin 24001660 052 0 600 F Type J 24001660 003 50 650 F Type J 24001660 056 0 200 F Type J 24001660 114 0 2000 F Type K 24001660 005 50 250 LIM assisas 24001660 008 0 100 C or Lin 24001661 001 0 200 C or Lin 24001660 010 5 50 Lin 24001661 022 0 500 F Type J 24001660 013 35 75 Lin 24001661 023 0 59 UIA iana 24001661 051 0 800 F Type J 24001660 014 90 210 C Type T 24001660 034 0 100 30 70 Lin 24001661 601 Honeywell Brand Pens Pen 1 Red 30735489 002 Pen 2 Purple 30735489 007 6 Pack 54 92 Universal Pens to Fit Honeywell Recorders Pen 1 Red 82 39 0202 06 Pen 2 Purple 82 39 0306 06 6 Pack 28 36 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales l
11. 923 1790 Fax 630 595 2386 sales lesman com Fax 262 923 1797 RECORDER L 238 SUPPLIES Recorder Charts and Pens Available from Lesman Stock Model Selection Guide Catalog i Catalog Description Number Description Number Chart Paper Normally Available from Lesman Stock 100 Box Unless Noted Chart Paper Normally Available from Lesman Stock 100 Box Unless Noted 24 Hour 0 to 100 C or Linear 24001660 001 8 Circular 7 Day 0 100 for Class 61 FA 3001571T 000 32 50 24 Hour 0 to 300 F Type J tee SERO Chart Paper and Pens Normally Available from Lesman Stock 1 Pack 24 Hour 0 to 600 F Type J 24 Hour 0 to 2000 F Type K 24001660 005 Honeywell 6 Color Ink Cartridge h FA 46182712 001 81 04 24 Hour 50 to 250 Linear 24001660 008 DPR180 7 7 Fanfold Chart 100 Divisions i 46190051 100 28 90 24 Hour 0 to 200 C or Linear 24001660 010 and 7 Roll Chart 100 Divisions FA 46190052 100 28 90 Honeywell 24 Hour 0 to 500 F Type J 24001660 013 i DPR250 10 10 Fanfold Chart 100 Divisions i 46182707 001 39 50 DR4300 10 24 Hour 0 to 800 F Type J 24001660 014 i Stripchart 10 Fanfold Chart 300 Divisions H 46182707 300 35 38 24001660 034 Recorders 10 Roll Chart 100 Divisions HM 46182708 001 Circular 24 Hour 90 to 210 C Type T Chart 24 Hour 85 to 190 RTD 24001660 047 gt Replacement Parts for Honeywell Circular Chart Recorders Normally Recorders 24 Hour 0 to 600mV 4 20 mA
12. IEdecordas Dapp miraa Pi sor nes Boum ory ee piant emg phase Cxwrucepabar hes oral ee E VE Uu fs ah he derdila PAC ete ea et Bde PA Bd LS E LU CR ny ea J V Lent es Chana fie CUIU i Qbue ab bleus Cima Eurer Cae Pen Fake Kxa ua pp PAR Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 www lesman com sales lesman com Choosing the Right Circular Chart Recorder Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 CHART RECORDERS 239 L V01 2015 DR4300 DR4500 Classic DR4500 Truline Chart 10 Circular 12 Circular 12 Circular Prints its chart as it records Choose from 150 Your choice of 5 000 With user configurable data date time preprinted charts preprinted charts process ID directly on the chart Up to 2 Up to 2 Up to 4 Input T Cs Type J K R S T RTDs Pt100Q T Cs J K R S T B E W5W26 RTDs Pt100Q Pt500Q Features 0 200 mV 0 1 0 5 1 5 or 0 10 VDC Linear 4 20mA 0 10 or 10 50 mV 1 5 or 1 10 V Optional Model T Cs B E W5Wh26 NiNi Moly Accuracy 0 35 Span Standard 1 F for T Cs 0 1 Span Field Calibrated 1 or Better for rotos Ranges Digital Input 2 with Control Alarms 2 per Pen 2 4 or 6 Auxiliary Output 1 per Pen 1 3 Communications 3rd Party Ethernet Bridge 3rd Party Ethernet Bridge Modbus RTU RS485 Li
13. Relays 2 Digital Inputs 8 Configurable Dl Discrete 24V Out 16 Configurable DI Discrete 24V Out Slot None Discrete Four Relay Outputs I O 8 Relays 2 Digital Inputs 8 Configurable DI Discrete 24V Out 16 Configurable DI Discrete 24V Out Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Lesman Instrument Company www lesman com sales lesman com Each X Series GR unit comes with an SD flash card mounting clamps CD ROM with user manual and TrendViewer software printed Quick Start guide precision 10Q resistors one per analog input two touchscreen stylii power cord or con nector and I O connectors Model Selection Guide Continued Catalog Avail Description Number ability Options for Advanced Graphic Recorder Model MIMU 90 240 VAC US Plug 2 4 oa Certifi cates Twenty Credits Thirty Credits Standard Panel Mount 0 00 Standard Panel Mount Rear Cover 79 00 TrendViewer Manual on CD 0 0 00 TrendViewer on CD Printed Manual F3399 Calibration Test Report F3391 and F3399 Reports Forty Credits 21 00 None Tags Stainless Steel Tag 3 Line x 22 Char None TrendManager Pro Single License Soft TrendServer Pro Single License ware TrendServer Pro with OPC Single Lic Screen Designer TrendViewer Screen Designer TrendManager Pro 90 240 VAC US Transmitter P
14. Tek EO Ethernet LAN network aware Data is transferred via a manual FTP iii 6 34 19 New Ow Tek THIN or a scheduled FTP block data transfer Process data is archived O a E in the database automatically Real Time function streams data e AEE AI from one or more recorders for a current window into the process Raaja s ab einen OPC DA serveris optional Configuration setups can be transferred via the network Model Selection Guide Description Catalog No Price Software Compatibility TrendManager Pro Software 50016133 501 328 00 Honeywell Trendview software for the GR series is backwards TrendServer Pro Software Single User Version 50016134 501 546 00 compatible to older X series recorders The update from older TrendServer Pro Software 5 User Pack 50016135 501 1420 00 TrendServer Pro and TrendManager Pro is free to licensed users TrendServer Pro with OPC Server Single User 50016136 501 819 00 and can be downloaded from Honeywell s website TrendServer Pro with OPC Server 5 User Pack 50016137 501 1638 00 System requirements Windows XP 32 bit or Windows 7
15. a desktop PC Providing full remote control of the unit through a web browser Independent Chart Speeds and Logging Rates Logging rates can be programmed completely separate from the chart speed so data can be displayed and stored at rates that best suit the applications Fuzzy Logging Increases storage capacity with data compression up to 100 1 or more Data is monitored to determine changes in process data If no changes are observed data is logged periodically If data changes rapidly it is recorded normally at the programmed rate Communications Ethernet Ethernet DHCP standard connection provides unlimited connectivity to local area networks LANs RS 485 Modbus Lets process data be transferred to other devices or to record data received in MODBUS RTU slave mode Simple Network Time Protocol SNTP Recorder time can be syn chronized over the Ethernet network via a SNTP client Web Server With the recorder connected to aLAN all process variables alarm and messages can be viewed from an Internet browser Security Total Data Integrity Data is stored in secure encrypted files making it easy to retrieve the data dependent on process information Data is automatically recognized without having to remember file names Password Protection Up to 4 levels of password protection with up to 50 different users are available Multiple levels of password pro tection and audit trail of actions enhance the security of the data
16. available A finished catalog number looks like this DR45AT _ O E 0 Model Selection Guide Part 1 Description Selection Catalog Avail Blue denotes options in stock at Lesman Number ability Truline Standard Model 1912 00 Truline With 6 Relays 1944 00 Truline Flow Recorder 1944 00 Truline HTST Dairy Recorder 3937 00 Truline Pasteurization Flow Recorder 3542 00 T C RTD mV 0 5VDC 4 20 mADC Radiamatic 0 10 VDC None T C RTD mV 0 5VDC 4 20 mADC Radiamatic 0 10 VDC None T C RTD mV 0 5VDC 4 20 mADC Radiamatic 0 10 VDC None T C RTD mV 0 5VDC 4 20 mADC Radiamatic 0 10 VDC None Control Output 1 Control Output 1 SP Program Pulse Output Non Control None Control Output 2 Control Output 2 SP Program HTST Model All options under restrictions must be selected except Channel 3 which is optional These selections are all included in base price except for Channel 3 ee Ba These Honeywell Trulines are in stock ready to ship to you within 24 hours H DRA5AT 1000 00 000 0 00000E 0 H DR45AT 1000 40 000 0 00000E 0 H DR45AT 1100 00 000 0 00000E 0 H DRA5AT 1110 00 000 0 00000E 0 H DR45AT 1111 00 000 0 00000E 0 Add In Stock Options Without Waiting 1944 00 2437 00 2330 00 2716 00 3102 00 We stock most option boards so we can build the model you need AND ship within a business day Replacement Pen Arm Standard H 30756304 501 181 00 Replacement
17. calculations etc Minitrend supports up to 16 extra pens Multitrend supports up to 48 extra pens Custom Screens 4 credits Import custom built screens that have been created in X Series Screen Designer Events 6 credits Into out of alarm Ack start stop reset totals digi tal input On Off state change T C burnout mark chart start stop logging digital output On Off Password Net Sync 5 credits Password change on one recorder replicates to other records on the same subnet Batch Groups 5 credits Ability to run batches with Start Stop Pause and Abort Up to 6 concurrent asynchronous batches Printer Capability 2 credits Provides ability to print recorder status text screens to USB PCL 1 printer Remote View 3 credits Extends the recorder s user interface to a PC Provides full remote control of the unit via a web browser OPC Server 10 credits OPC compliant software for real time data exchange between servers and clients recorders controllers PLCs etc HealthWatch Maintenance 2 credits Keeps track of critical recorder life actions for diagnostics and preventative maintenance Includes birth date power cycles Time On Off Hi Lo CJC values hardware soft ware version relay operations calibration date and backlight operation Modbus Master 10 credits Fetches data from modbus slaves Password Net Synch 5 credits Password change on one recorder is replicated on other recorders on the
18. external transmitter power supply To totalize a variable such as a flow signal you select the input and preset the 8 digit display scaling factor eliminating the need for addi tional integration hardware You can reset the totalizer with digital input from a remote site And set a low flow cutoff in percent of range Digital Controller The DR4500 includes an integral microprocessor based single loop PID controller Choose from a variety of output types including duplex variations for heat cool applications as the output for your final control element Depending on the type you can set control action as on off PID A PID B PD with manual reset or three position step control All DR4500 series recorders include self diagnostics that check critical operations Qe and provide error messages to alert you to detected faults At start up one diagnostic Sages is run on selected circuitry Key tests let you n Start diagnostics on demand to check the keypad and displays Visit our website to download complete specs and z manuals Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Honeywell Specifications Sampling Rate 3 times per second Input Filter Single pole low pass section software selectable time constants off to 120 sec Digital Displays Vacuum fluorescent alohanumeric displays 6
19. same subnet Hardware Lock 2 credits Locks out hardware configuration E mail 3 credits Send e mail on alarm or event Reports 3 credits Generates min max totals averages current pen value reports as RTF files Print e mail or export to flash drive Secure Communications 3 credits Conforms to DPWS Device Profile for Web Services Wisconsin and Upper Peninsula Michigan PAPERLESS 251 L Phone 800 837 1700 262 923 1790 Fax 262 923 1797 q RECORDERS Data Storage Internal Data Storage At least 256MB expandable internal non vola tile flash memory is available for data storage and chart history Internal memory capacity days Logging rate 1 sec Pens 256MB 740MB 1850MB 3 7GB 4 172 days 1000 days 1222 days 4960 days 8 86 days 500 days 611 days 2480 days 16 43 days 250 days 311 days 1240 days 32 21 days 62 days 155 days 310 days 48 14 days 40 days 103 days 206 days Data Export Removable SD flash and USB flash storage device pro vides multiple data storage alternatives Data is stored in a secure binary encrypted format with the recorder s configurations provid ing added security of the data files External USB Devices The recorder has two USB host ports one front and one rear for attaching external devices keyboard mouse or a data storage key The keyboard and mouse can be used to navigate the recorder s screen along with text entry Remote Control Extends the recorder s user interface onto
20. state contacts Selects one configured input Communications 300 600 1200 2400 4800 baud Parity Odd or even Characteristics 4000 max length Two wire multidrop Controller Configurable Parameters Controller Operation Manual Automatic with local or remote setpoint Tuning Gain or Proportional Band 0 1 to 999 9 Rate 0 08 to 10 min Reset 0 02 to 50 min repeat or repeats min Manual Reset 100 output Cycle Time 1 120 sec Lockout None to maximum Autotune Step Size 10596 to 10596 of output Algorithm Control On Off PID Proportional Band Manual Reset 3 Position Step Output Current ProportionalSimplexor Duplex Position Proportional Time Proportional Current Relay Duplex Heat Cool Control P D Tuning Sets 1 or 2 Setpoint Source Local Remote or Local 2 Ratio IN2 20 00 to 20 00 Bias 999 to 9999 Setpoint Tracking Yes No Power up Mode Recall Manual Auto using local or remote setpoint High LowSetpointLimits 0 10096 span Action Direct or Reverse High Low Output Limits Dropoff Value 596 to 10596 output Deadband 596 to 25 096 Output Hysteresis 0 596 span Failsafe Output Within limits Proportional Band Units Proportional Band 96 or Gain Reset Units Repeats Min or Mins Repeat Universal Controller Output Option On Off or Time Proportional SPST electromechanical relay Normally open N O or normally closed N C contacts selectable On Off Duplex 3 Position Step
21. 1 CFR Part 11 process validation needs The GR s 5 color active matrix TFT display with intuitive bar charts digital values and trend displays makes it easy to interpret process data and take action The heavy duty durable touchscreen provides easy data entry and quick navigation through the menus A complete contextual help system can be accessed on the recorder screen The Ethernet connection with support for a variety of protocols provides unlimited connectivity to your local area network DHCP au tomatically acquires an IP address for network communications SNTP synchronizes the recorder s clock over the network The built in web server makes all process variables alarms and messages viewable through a standard web browser The eZtrend GR has a front USB port for attaching external devices like a keyboard mouse or USB data storage key Firmware credits provide a flexible way of adding features to the recorder without having to upgrade firmware or add hardware Credits can be applied as needed to turn on functionality See sidebar on page 100 for a detailed description of available credit options Data is stored in secure encrypted files so it s easy to retrieve data dependent on process information without having to remember file names Up to four levels of password protection are available for up to 50 users Multiple levels of password protection and an audit trail of actions enhance data security An Extended Security Sy
22. 3 hours per revolution 5 000 different charts available Entire process at a glance Digital displays are easy to read at a distance or in dim light Selectable displays include PV indication SP deviation alarms control mode auto manual temperature units F C and setpoint program run hold It s Your Option Expand the functionality of your DR4500 Classic with these options Control outputs Time current or position proportioning three po sition step control simplex or duplex with mixed output forms fully field selectable to provide the utmost versatility Control algorithms Configurable for On Off PID A PID B or PD with manual reset 1 or 2 control loops available Alarms Ties soft alarms to up to 6 integral SPST relays Doorlock stainless steel door Flow totalization Expands your recorder s operation to meet spe cial application requirements Operator Interface Two digital displays present the process variable PV controller setpoint output deviation from reference input dry bulb temperature totalization value or engineering units as desired In configuration mode digital displays show English prompts and values for entering data Indicators light to show alarm condition which chan nel PV is on display remote setpoint which output relay is on selected temperature unit and operating mode The deviation bargraph shows if the PV is at above or below your desired setpoint The keypad als
23. 40 VDC 8 I O SPNO 1A 24 VDC Activation Fully programmable internal alarm levels Assignable to any relay output Digital Input Two DI using dry volt free contacts on the 8 relay card Math Basic math standard on all X Series recorders include Add Subtract Multiply Divide Modulo and power Full maths option supports up to 100 characters freeform math expression for each pen Includes Sine Soc Tan Log Parentheses comms variables free memory and access to any data item variable Totalizers Onetotalizer per input Totalizer value assigned toa pen for display and storage Totalization values are 10 digits plus exponent Approvals CSA optional CSA22 2 CEWKA JL QR No 1010 1 2004 Cert L211230 UL ANSI UL61010 1 2004 File 201698 CE mark Enclosure Rating Front panel designed to NEMA 3 IP54 Available with NEMA 4X IP66 Notes and Restrictions c Requires Expansion Board 1 Standard inputs include T C mV V mA ohms and RTD actuations 2 Required when ordering analog input discrete input output or communica tions transmitter power card options 3 Analog input card supports T C mV V mA ohms and RTD actuations with enhanced input isolation 4 Relay outputs are high level 3 Amp 240 VAC non inductive load Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 PAPERLESS RECORDERS 249 T V01 2015 Fax 262 923 1797 Ordering Instructions Make one selection from each
24. 5 7 High Resolution Digital Color LCD Multitrend GR 12 1 High Resolution Digital Color LCD Industrial rugged touchscreen with pushbutton navigation Clear and intuitive menu operation Custom screens Flexible Universal Input Options Minitrend GR Up to 16 Analog Inputs Multitrend GR Up to 48 Analog Inputs Comprehensive Connectivity TCP IP and RS 485 Modbus Protocol 10 100 Ethernet DHCP web FTP OPC USB ports for keyboard and mouse and memory Plus Date export in Comma Separated Variable CSV format NEMA AX IP66 option Health Watch for preventative maintenance Remote Access Advanced data analysis at your PC Independent chart and logging speeds Rapid review and replay of data at recorder Approvals CE CSA UL FM Upto 50Hz 20 msec Logging Standard Screens Digital screens display combinations of charts bars and digital data can be configured Minitrend GR supports up to 20 screens Multitrend GR supports up to 32 A small sample of standard screens are shown below Logarithmic Scales Displayed scales can be set linear or logarithmic Replay with Zoom Select replay mode and zoom in on a specific area on the screen The touch screen makes it fast to review and analyze historical data DOM screen 29 Sep 05 06 2052 CENE fo er gear neui o is M CE 96 98 P99 98 Total 55 478 f Illinois Indiana Missouri and lowa Phone 800 953 7626 630 5
25. 797 AMS2750D Standards Compliance with X Series Recorders Honeywell X Series paperless recorders make it easier for youto comply with AMS2750D standards If your process is subject to NADCAP audits these recorders can collect the data and produce survey reports to show that your temperature instrumen tation is in compliance Two modes in the recorder address the AMD2750D specification Process mode can be used to track calibration due dates and thermo couple usage conditions forthe process equipment and alert the data Typically this would be used on a recorder mounted on the process furnace AMS2750 temperature unifor mity mode available only on the Multitrend lets you use the recorder asa field test instrument to doa temperature uniformity survey and create a data file used to generate required reports AMS2750D Process Mode Process mode lets you track thermocouple usages based on thermocouple type the number of times they are used and the temperatures they see to deter mine if they are still within the Inst Ca AMS2750D specified allowable n uses It will also track due dates ws TC Expires gt for System Accuracy Tests SAT ins Wi cepe wo when the next temperature wee uniformity survey is due and when the recorder is due for calibration 5 Days Each item provides a five day warning through color coded screen icons before indicating an out of tolerance condition
26. 815 270 to 1000 133 to 593 18 to 871 7 to 410 196 to 1371 29 to 538 0 to 1371 0 to 682 18 to 1704 184 to 371 133 to 316 K 320 to 2500 K low NiNiMoly N 20 to 1000 32 to 2500 NiNiMoly N low 32 to 1260 R S 0 to 3100 T 300 to 700 T low 200 to 600 W5W26 0 to 4200 18 to 2316 W5W26 low 0 to 2240 18 to 1227 RTD IEC o 0 00385 1000 5000 300 to 900 184 to 482 4 to 20mA 0 10 mV 10 50 mV 1 5V 0 10V Can require field calibration to achieve rated accuracy below 1 000 F for Type B thermocouple and below 200 F for Type E thermocouple Thermocouples Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 CHART RECORDERS 245 L V01 2015 Fax 262 923 1797 Dimensions Surface Mounting Rear View Alarms Indication Setpoint Value Engineering Units Setpoint Type None Inputs 1 4 PV Deviation Output Rate of Change or Shed Setpoint State High or Low Hysteresis 0 0 to 5 0 of span Total 1 Same for 2 3 and 4 Total Read only Reset Total Yes or No Total 1 Disable or Enable Rate Minute hour or day Scaling Factor 1 10 100 1000 10 000 100 000 or 1 000 000 Options Alarm Output 2 4 or 6 relays available First two are SPST electromechanical relays rated 1A for 120 VAC and 0 5A for 240 VAC resistive Relays 3 6 rated 5A for 240 VAC resistive Digital Input 20 VDC source for external dry contact or isolated solid
27. 9 0302 06 6 Color Ink Wheel M 46180501 001 Circular Universal Purple Pen 0 6 Nib Lj 82 39 0306 06 Honeywell Pen 1 Ink Gartridge Blue HI 46187001 001 15 07 Chart Universal Purple Pen 0 37 Nib 92 39 0206 06 DPR100 C D Pen 2 Ink Cartridge Red M 46187001 002 15 07 Recorders Universal Green Pen 0 14 Nib f E 82 32 0314 05 4 Stripchart 4 Fanfold Chart 50 Divisions M 46187045 050 26 76 Chart Paper Normally Available from Lesman Stock 100 Box Unless Noted Recorders 4 Fanfold Chart 100 Divisions FA 46187045 100 26 76 4 x 30 Ft Roll Strip Chart 1 Boll M 300SVA 2824 30756113 501 30756150 001 51404453 502 30756140 501 30757571 501 30756141 003 30754957 501 30754919 501 30754922 501 30756304 501 4 Roll Chart 50 Divisions B 46187044 050 14 02 LL EmxOE X3 Rs Dickson 8 Dia 7 Day 0 to 100 Fa C412 ls He Recorder Circ Charts 8 Dia 7 Day 20 to 126 0 100 rH BI C417 e Si ay VS OLET TT P d Looking for charts or upply StOFE Foxboro 12724 Hour 0 199 ange M 898413 He gale p Em HE a 5 y if Pia 27 7 QUEPressure 6 Dia 7 Day 50 to 115 50 Box P 6282 169 pens for your recorders 4 W Ssensitive 6 Dia 24H 160 to 280 50 Box E 6282 176 ag Circular 6 Dia 7 Day 25 to 40 50 Box EI 6282 240 You ll find them at www lesman com gb Lo Tenant 6 Dia 7 Day 15 to 50 50 Box H 6282 301 Search by part number for fast result
28. 91 Certificate of Performance F3399 Custom Calibration Test Report Certificate of Conformance and ID Tag e EDDA T B E CHART RECORDERS 243 L Fj 82 39 0306 06 28 36 i4 82 39 0202 06 28 36 d Not available with NEMA4X Door Combustion Safety Recorders and Digital Indicators Controllers Solids Flow and Motion and Efficiency Data Acquisition and Programmers Process Valves sJouJuJeJboJg SJO3e2Ipu e3161q pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I D ot gt a LI Uu oO S Ad ualdyjy pue Ajajes uonsnquJo S AJLA SS DO1d L 244 RECORDERS Fax 630 595 2386 d i m PO 3 asih ON pa aa E meso WIE DATE Li d au ES ul TN 3nn rnm nooamcTCD DIN NIIT INICITDHNIS FAKE FER RANGES ENGINEERING cuu ur Fri m MECI CT UN HLL MEASURED PRULES SES ui T ITIN UTHT IIT mee ULI HL PH J ILI IERIE mE Search www lesman com for DR4500 Truline Ga I Standard Features Extreme Accuracy Typically less than 1 F for usable thermo couple ranges meets MIL spec requirement for Type T and Pt100Q RTD 0 1 or better for voltage ranges Universal Inputs Standard low level electrical input signals are configurable for hassle free changes in the field Easily expand or compress ranges within their limits to meet your specific need Mixed input actuations can be displayed on the same linear chart Accepts all thermocouples RTDs Pt100 or Pt500Q relative hu
29. 95 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Options Status 7 ale tal lle sci Seal iat e emere m Bi Eu Bur fud dur Pd hi Fur du qa ou d dmm 2 RRL EAGLES Firmware Credit System Honeywell s credits system is a flexible way of adding to the recorder features withoutafirmware upgrade Credits can be usedto add functions until the total number of credits purchased has been depleted Additional credits can be purchased later and added to a recorder after installation Firmware Options Note Extra Pens can be used to display and store the results of calculations totalizers counting variables imported viacommunications or to store values Free Form Math 4 credits Handles math expressions that can con sist of expressions up to 100 characters in length See Note Free Form Math with Scripting 6 credits Powerful multi line scripting ability solves complex state based applications See Note Fast Scanning Mode 5 credits Sample rate of 50 samples second for up to eight pens 20 mSec sample Totalizer Sterilization Calculation 4 credits Each pen can be associ ated with a totalizer Totalized values can be displayed and recorded multiple totals can be calculated from the same variable The totalizer function can handle Fo and Po Sterilization calculation See Note Extra Pens 2 credits 4 extra pens to store and display totalized values results of
30. AMS2750 Process Mode requires five credits to function and is available on all three X Series recorders AMS2750 process is used when the recorder is attached to the pro cess in the role of a recording device All SX OX and QXe recorders can operate in the Process mode and can be used as a process recorder to monitor process timers for calibration due dates and thermocouple usage set by the user Process mode adds some new status screens and timers to the recorder to help with AMS2750D compliance of the process giving a countdown to SAT and TUS intervals as well as control thermocouple and instrument calibration AMS2750 process mode is available on all X Series recorders and requires five credits in the X Series firmware credit system and the rear cover Option R in the model selection guide or a retrofit rear cover Countdown Timers AMS2750 tools include individual countdown timers for System Ac curacy Test SAT temperature uniformity survey TUS Control TC and Instrument calibration TUS and SAT countdown timers track the next date for survey test A timerreset screen showsa suggested date for SAT or TUS depending on Furnace Class material and instru mentation types Instrument Cal Timer Resat Alesse enter the date for the next Instrument Cal Enta the new date to change it and use CK to confinm or Cancel to exit You may abo enable thi timer Iretrument Cal daba me Sept 208 A separate timer provid
31. Abrasion Resistant Pen M 30756304 502 229 00 Replacement Charts M 30755317 001 61 46 Restrictions a Not available without ordering channel 2 b Not available without ordering channel 3 c Not for T C Types B N R or W Includes calibration for 200 Burns Bulb d Controller can be set only for 4 20 mA output e Available only when chart rotation is between 24 and 744 hours f Option price already included in base price g Available only with 2 inputs Control output 1 Option 6 4 20 mA output Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Honeywell Lesman Instrument Company www lesman com sales lesman com Model Selection Guide Part 2 Description Selection Catalog Avail Number ability A A A A A DR45 Truline Model T RIWIHIP 2 ai Blue denotes options in stock at Lesman Auxiliary 4 20 mA Output RS485 Modbus Communication RS485 Modbus Communication anig 4 2 mA ey Output External Interface None 2 Alarm Outputs 2 Digital Inputs 4 Alarm Outputs 2 Digital Inputs 6 Alarm Outputs 2 Digital Inputs 1 Alarm Timer Out 2 Digital Inputs None Software Totalization Input 1 Totalization Inputs 1 2 Totalization Inputs 1 4 Fo Sterilization Calculation Math Totalization Input 1 Math Totalization Inputs 1 2 Math Totalization Inputs 1 4 Math Enclosur
32. DC Transmitter Power Supply Digital Display Configuration Keypad Recording parameters are easily setup us ing simple prompts a keyboard Two Alarms per Pen Optional Up to Two PV Totalizers Optional More Sophisticated Control Options Up to two controllers with current relay outputs On Off duplex time proportion ing plus alarm PID or PD MR algorithms HI LO Pen with Decimal Capability Support For Additional Thermocouples Honeywell s DR4300 is ideally suited to applications handled by low costanalog recorders with accuracy requirements not exceeding 0 50 and is appropriate for most high performance applications requiring accuracy not exceeding 0 25 Both recorders use 10 charts and are available with one pen or two Each DR4300 has built in diagnostics that check critical recorder op erations at startup and provide error detection or messages to alert you to potential faults In addition a built in step pattern test can be run on demand to ensure proper pen and chart drive motor operation Configuring the basic model is easy just select the pre configured range actuation and chart speed An optional display provides additional flexibility to select other chart ranges input actuation control or alarm parameters and chart speeds Upper and lower displays let you view the process variable PV the control setpoint control output deviation from setpoint or totalizer In the setup mode digital displays are pre
33. Lin 24001660 052 Available from Lesman Stock 24001660 038 DR4200 4300 4500 Chart Drive Motor Hub Kit 24 Hour 50 to 650 F Type J 24001660 114 DR4200 4300 4500 Chart Hub Kit Pack of 2 24 Hour 0 to 200 F Type J 7 Day 0 to 100 C or Linear 24001661 001 DR4300 Printed Circuit Assembly Record Control 24001661 022 DR4500 Alarm Output Kit 7 Day 5 to 50 Linear 7 Day 35 to 75 Linear 24001661 023 DR4500 Display Board 24001661 051 DR4500 Input Upgrade Card 7 Day 0 to 50 Linear 24001661 601 DR4500 Keypad Membrane Switch Kit 7 Day 0 to 100 30 to 70 Linear Starter Box 25 24H 7D 0 100 Lin 30755820 001 DR4500 Motherboard DR4500 Printed Output Circuit Board T llindgnelimal Chart M 30755317 001 DR4500 Truline Replacement Pen Arm Assembly Honeywell Starter Box of 25 24H 7D 0 100 M 30755311 001 DR4500 Truline Pen Motor Servo Plate Assembly 30754975 503 12 Circular 7 Day 0 100 Linear I 30014479 000 DR4500 Truline Processor Board 51309355 502 Chart 24 Hour 0 100 Linear FA 30014012 000 Fiber Tip Pens Normally Available from Lesman Stock 6 per Pack Recorders 24 ud MESSIS Lea ES Honeywell Red Pen 0 37 Nib M 30735489 002 24 Hour 50 250 FA 30016378 000 Fiber Tip Honeywell Purple Pen 0 6 Nib M 30735489 007 24 Hour 5070 150 BI 30680015 051 Pens for Universal Red Pen 0 37 Nib M 82 39 0202 06 Chart Paper and Pens Normally Available from Lesman Stock 1 Pack Honeywell Universal Red Pen 0 6 Nib H 82 3
34. Product Classification Complies with EN61326 Class Cord Connected Panel Mounted Industrial Control Equipment with protective earthing grounding EN 61010 1 Enclosure Rating Front panel NEMA3 IP55 Optional NEMA 4 IP66 Installation Requirements Category Il Overvoltage EN 61010 1 Pollution Degree 2 EMC Standards Safety Emissions EN61326 Class B Immunity EN61326 In dustrial Levels Complies with EN61010 1 2001 Panel Mounted Equipment Terminals must be enclosed within the panel Analog Inputs Number of Inputs Minitrend 4 6 8 12 or 16 input channels Multitrend 4 6 8 12 16 24 32 40 or 48 input channels Visit Lesman comfor input actuations Minimum Input Span Fully configurable with span limitation of the range selected with 4 under range to 496 over range capability 50V Range 2 Burnout T C High Low or None Cold Junction Compensation Internal compensation with the ability to manually adjust values External Input for compensation External CJC value specified Input Resolution 0 001596 16 Bit ADC Input Impedance Current loop resistance DC 10Q use 0 1 external resis tor All others gt 1 MQ Volts gt 10MQ Source Impedance 7 C and RTD 100 per lead maximum CU10 150 Square Root Extraction Standard on every input type Sensor Compensation Single and Dual point Input Sampling Rate Available slots support up to 8 analog inputs each Minitrend QX has 2 slots Multitrend SX has 6 the inpu
35. RECORDERS Fax 630 595 2386 Ordering Instructions Choose one option from each table section Follow the availability column down to view any restrictions A finished catalog number looks like this Catalog Avail Description Number ability Minitrend GR 5 7 Graphics Recorder TVMIGR J 2730 00 Slot A None Four Analog Inputs 420 00 Six Analog Inputs 578 00 Eight Analog Inputs 735 00 Four Pulse Inputs 578 00 Slot B None Four Additional Analog Inputs Six Analog Inputs Eight Analog Inputs Four Pulse Inputs Two Analog Outputs Four Analog Outputs Slot G None 1 Discrete Output Std Discrete Four Relay Outputs I O 8 Relays 2 Digital Inputs 8 Configurable DI Discrete 24V Out 16 Configurable DI Discrete 24V Out Multitrend GR 12 1 Graphics Recorder Slot A None Four Analog Inputs Six Analog Inputs Eight Analog Inputs Four Pulse Inputs Slot B None Four Analog Inputs Eight Analog Inputs Four Pulse Inputs Slot C None Eight Analog Inputs Four Pulse Inputs Slot D None Eight Analog Inputs Four Pulse Inputs Slot E None Eight Analog Inputs Four Pulse Inputs Two Analog Outputs Four Analog Outputs Slot F None Eight Analog Inputs Four Pulse Inputs Two Analog Outputs Four Analog Outputs Slot G None 1 Discrete Output Std Discrete Four Relay Outputs I O 8 Relays 2 Digital Inputs 8 Configurable DI Discrete 24V Out 16 Configurable DI Discrete 24V Out Slot H None Discrete Four Relay Outputs I O 8
36. adeable If you need a recorder that you can add options to later see the DR4500 Truline and Classic models on the next six pages Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 One Pen Recorder Two Pen Recorder par pee Approvals Certificates V01 2015 Model Selection Guide Catalog Avail Description Number ability No Display No Display CE Mark With VFD Display VFD Display CE Mark No Display No Display CE Mark With VFD Display VFD Display CE Mark None 2 Outputs Alarm On Off Control 1 PID Control 1 PID Control SP Program Timer 2 Outputs Alarm1 Timer 4 20 mA Retransmission Output FM Approved Limit Control FM Appr Limit Control Timer Out None 2 Outputs Alarm On Off Control 1 PID Control 1 PID Output SP Program Timer 2 Outputs Alarm1 Timer 4 20 mA Retransmission Output FM Approved Limit Control FM Appr Limit Control Timer Out None Electromechanical Relay Solid State Relay Open Collector None Electromechanical Relay Solid State Relay Open Collector Gray Door Blue Door Gray Door with Keypad Blue Door with Keypad Stainless Steel Door Standard Latch Door Lock Chart Plate Seal Universal Power 120 240 VAC 50 60 Hz Universal Power 24 VDC Transmitter Power Communi None mE cations RS485 Modbus RTU NEN No Digital Inputs 00 _ Digital Inputs DO _ No Totalizer Function m 00 Totalizer TO No Dig
37. arm acknowledgement Alarm Damping 1 sec to 24 Hours Hysteresis 100 of pen scale Common relay output 1A 24 V can be activated on any alarm Display Chart Speeds Independent of logging rate 3 chart rate categories Slow 1 5 or 10 mm hour Medium 20 30 60 or 120 mm hour Fast 300 600 1200 or 6000 mm hour Combinations of rates can be mixed and chart speeds can be set independently for each chart Data Replay Mode Data replay facility on chart displays at normal fast or slow speeds with zoom and cursor Recorder Identification Recorder name Screen name Time and Date Messages Screen Message screen displays system information and records any setup activity that has been changed It also provides warning and error message updates lists alarm activity and will display user defined marks on a chart Password Protection Multiple Administrator control of password setup and management with four levels of password protection Up to 50 different users available Password protection restricts user entry to recorder setup and specific screens Engineer Highest access to all levels Supervisor Next highestlevel including access to levels below Technician Third level includ ing operator access Operator Lowest level of access CE Conformity CE Mark Conforms with the protection requirements of the following European Council Directives 73 23 EEC the Low Voltage Directive and 89 336 EEC the EMC Directive Immunity
38. can beimported Custom Screen firmware option is required Digital values displayed include alarms on bars engineering units pen name tag time and date 20 character description and totalized values Data Storage Removable Media SD Flash card supports up to 8 0Gb Local Mass Storage USB memory key up to 120Gb USB hard drive up to 120Gb Internal Data Buffer Non volatile 256MB to 3 7 Gb 50 million to 1 2 billion points Setup and Screens Stored internally on non volatile memory Data Saving Period Related to log rate number of pens totals and alarms Data Format Honeywell binary encoded format Recycling Mode First In First Out Power Requirements Voltage VRMS 90VAC to 250 VAC auto select Fre quency 50 60Hz Optional Instrument Power 20 to 50 VDC 20 to 30 VAC Common Relay Output SPNC NC common alarm relay Two contacts normally closed when the recorder is powered Rating 24 V 1 Amp Battery Battery backup for clock Lithium battery 10 years life Recorder powered 4 years life typical Recorder unpowered Clock Tolerance 20ppm to a resolution of 1 second at 25 C Format se lectable for MM DD YYYY or DD MM YYYY Summer Winter manual time adjustment or via communications SNTP Client or Server included for synchronizing over Ethernet Alarm Setpoints 6 per pen integral soft alarm setpoints announce selected out of limit conditions Alarmtriggers can be set for Hi Lo Deviation latched or unlatched for al
39. digit display dedicated to PV Alternate information displayed at setup 8 digit display shows key selected operating parameters and provides guidance during setup Indicators Channel PV display Ch 1 2 Alarm status Alm 1 2 Control output Out 1 2 Remote setpoint RSP for Out 1 Temperature F C or engineering unit Control mode Auto Man Chart Speed 8 hrs 24 hrs 7 days or selectable 6 744 hrs rev Case NEMA 3 molded foam Noryl gasketed door NEMA4X SS door optional Pen Disposable fiber tip ink cartridge Line length 1000 ft cartridge One pen Purple Two pens Purple and red Chart 12 diameter standard markings 4 62 calibrated width Approvals UL approved depending on model FM approved for Class Div 2 Groups A D areas depending on model See Model Selection Guide for restrictions Alarm Output Two SPST electromechanical relays Relay contact rating 1A 120 VAC 0 5A 240 VAC resistive Digital Input 20 VDC source for external dry contact or isolated solid state contacts Selects one configured input Totalizers One or two depending on model 8 digit totals with multi plier on digital display Auxiliary Linear Output Option Can be used as second current out put for current duplex modes 21 mA DC into 0 1000Q grounded or non grounded load Output range can be set between 0 and 21 mA direct orreverse action Can beconfigured for any one of 10 parameters Resolution 12 bi
40. e and Design Options Gray Door with Glass Window Gray Door with Acrylic Window Blue Door with Glass Window Blue Door with Acrylic Window Stainless Steel Door w Acrylic Window NEMAAX Door with Glass Window NEMAAX Door with Acrylic Window NEMAAX Door HTST with Divert Lights None Keyed latch Door lock None Configuration lockout chart plate seal Lockout chart plate seal Illumination Chart illumination No approvals CE mark CE mark UL listing CSA approval CE mark FM approval CE UL FM CSA approval UL listing NDUUVUWA WU CO FM approval CI 1 Div 2 Gr A D UL FM CSA approval cCwmuZ None Customer ID Tags 30 Character Max Certificate of Conformance Customer Calibration Test Report Certificate of Conformance ID Tag Customer Calibration and ID Tag Product Configuration Printed User s Manual English 5 Available only with 2 inputs Control output 1 Option 4_ Available only with Modbus communications 4 20 mA auxiliary output 4 20 mA control output and channel 1 and 2 inputs Available only with Control output 1 Available only with Control outputs 1 and 2 Customer must supply configuration worksheet Customer must supply Input Actuation Type and Range for each input c Nx lt Illinois Indiana Missouri and lowa Lesman Instrument Company Phone 800 953 7626 630 595 8400 www lesman com Fax 630 595 2386 sales lesman com Fax 262 923 1797 Honeywell Wisco
41. empted by prompts and values for entering the configuration data Indicators light to show which input channel PV is being displayed which output relay is active the selected temperature unit and the controller s mode of operation The DR4300 recorder is available with an integral microprocessor based single loop PID controller for each pen A variety of output types current time proportional simplex or duplex control with electrome chanical relays solid state relays or open collector outputs are available Depending on the output type you can configure the control action as On Off PID A or PD with manual reset Options Alarm Outputs Integral alarms activate external equipment Totalizer Totalizes a variable such as a flow signal on one or both pens Provides a 6 digit digital display indication ofthe totalized value with reset capability Transmitter Power 24 VDC output power up to two transmitters Digital Inputs Two digital inputs per pen B E V5WW26 NiNiMo plus 0 100 and 0 200 mV and 0 10 VDC Input Actuations Pmp o 454 to 1832 270 to 1000 420 to 700 251 to 371 320 to 2500 196 to 1371 E 200 to 1100 129 to 593 T low 200 to 600 129 to 316 Thermocouple K low 20 to 1000 29 to 538 J 0 to 1600 18 to 871 Nicrosil Nisil 0 to 2372 18 to 1200 R S 0 to 3100 18to 1704 W5W26 0 to 4200 18 to 2316 J low 20 to 770 7 to 410 Ni Ni Moly 32 to 2500 0 to 1371 B 105 to 3300
42. erformed on power up or can be run on demand CHART Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Lesman Instrument Company Wisconsin and Upper Peninsula Michigan www lesman com Phone 800 837 1700 262 923 1790 sales lesman com Fax 262 923 1797 DR4500 Truline 12 Circular Chart Recorder Enhanced Features Expanded Math Pack Features Calculate and print mass flow and BTU values right on the chart with new functions built into the Math Pack option Math Pack now includes Summer Multiple Divider with Square Root Multiplier with Square Root Multiplier Divider Multiplier Subtractor Multiplier HiLo Select Decimal Point Selection Additional decimal point selection comes standard on all models for use with narrow ranges like pH Additional Auxiliary Output Add a 4 20 mA output to any model Truline recorder Chart Timeline New chart timeline functions come standard More Flexible Totalizer Improved totalizer option now includes remote reset low flow cutoff and grand totals Security Security option lets you install a wire seal over a switch to prevent entry into configuration Call Lesman for details Options Control Outputs Up to 2 single loop PID digital controllers are available so you can program the exact control actuation for your process Field selectable algorithms include on off time current and position proportioning and duplex variatio
43. es a countdown to the next instrument orcontrol thermocouple calibration Expendable Type K Base metal Serial Number 0123 Certificate No NA958 K Installed on 02 11 2008 Days Left 0 Uses Left 30 Calibration Due 02 09 2009 o c7 x Thermocouple Usage Tracking Thermocouple Usage Tracking is available with both TUS and Process options It tracks thermocouple use within a recorder that s being used as a process instrument and dis plays the results as a status screen This give an indication to when thermocouples need replacing dependentonload cycles and other factors specified in AMS2750D AMS2750D Temperature Uniformity Survey Mode A Temperature Uniformity Survey TUS is a key requirement for a NADCAP audit It de termines how well a furnace performs relative the temperature within the volume of the working area of the furnace compared to the programmed setpoint X Series TUS mode allows a recorder to be set up as a testing device rather than an in process recorder to monitor and record the tempera ture uniformity of thermal processing equipment per AMS2750D Plus it monitors thermocouple usage and reports their status Another key factor in the heat treatment process is monitoring the number of times thermocouples have been used and the temperatures to which they ve been exposed to ensure they are accurate and reliable Unlike in Process mode TUS mode lets you set up a survey
44. esman com Ordering Instructions Make one selection from each table section at the right Check the restric tion letters to ensure availability A finished catalog number looks like this DR4301 Specifications Input Impedance mA DC 2500 VDC 200KQ RTD 13 3KQ Others 10 MegQ Span Step Response Time 7 sec max Reproducibility 0 1 of span Input Filter Without display Analog with time constant of 3 seconds and digital with time constant of 1 second With display Analog with time constant of 3 seconds and digital adjustable 0 to 120 seconds Optional Digital Display Vacuum fluorescent alphanumeric Upper 4 digit display dedicated to the process variable or setpoint 6 digit lower display shows key selected operating parameters Controller Output On Off or Time Proportional One SPDT electromechanical relay Control action can be set for direct or reverse For limit controller SPDT electrome chanical output Relay contact ratings Resistive load 5A 120 VAC 2 5A 240 VAC Inductive load 50 VA 120 VAC or 240 VAC Solid state relay contact rating 0 8A 120 VAC Open collector output contact Rating 12 mA 24 VDC Resolution 3 33 mSec Cycle time 1 120 seconds Current Proportional 21 mA DC max into a grounded or non grounded load of 0 to 600Q 4 20 mA output range can be direct or reverse acting Resolution 11 bits Accuracy 0 5 full scale Time Proportional Duplex Variation of time proportional f
45. ess of 2mm to 100mm Adapter kits available for covering existing panel cutouts Dimensions WHD Minitrend 5 67 x 5 67 x 7 87 5 43 Full DIN square cutout Multitrend 11 34 x 11 34 x 9 72 11 06 square panel cutout Both Models Additional 3 15 clearance recommended for a straight type power cable and signal connectors Wiring Connections IEC Power Plug Removable terminal strip for input and alarm connections Environmental and Operating Conditions Ambient Temperature 32 to 122 F 0 to 50 C Relative Humidity RH 10 to 9096 Vibration Frequency 0 to 70 Hz Acceleration 0 1g Mechanical Shock Acceleration 1g Duration 30 ms Mounting Position from Vertical Tilted Forward 40 Tilted Backward 65 Tilted to Side 65 Warm Up 30 minutes minimum Seismic Qualification Complies with IEEE 323 1974 and or 1983 and IEEE 344 1975 and or 1987 optional b S LY r E i 3 Lu M 4 gt l In Mar 4 zd 62 Soren uam i i i i le xS if L E 4 i s Iq i r ij i m z Ss E 5 b amp i E H E I E i XS B Solids Flow and Motion Controllers and Programmers Digital Indicators ZO Su S5 Og pum ox vm cc C em Combustion Safety and Efficiency Process Valves uonisinb y ejeq SJouJuJeJ50Jd pue SIapJOIOY SJO3e2Ipu e1i6iq pue sJ9 OJ3u0D uono A pue MO Spi os Ad ualdyJW pue Ayajes uonsnquJo S AJLA SSa20Jd PAPERLESS
46. igital Process Reporter 3985 00 Call Honeywell DPR250 10 Multipoint Digital Process Reporter 4899 00 Call US Accessories A FE AMS2750 D Standards Compliance with Honeywell X Series Recorders 255 E fi E E Circular Charts and Pens IN STOCK at Lesman 238 J Honeywell TrendManager Pro Configuration and Analysis Software 328 00 258 Honeywell TrendServer Pro Configuration Analysis and Monitoring Software for Paperless Recorders 546 00 256 Honeywell TrendViewer Software for Paperless Recorders FREE 256 2 E GO utc So DE su 2g t O U Looking for charts or pens for your recorders N U gt You ll find them at Recorder S gt www lesman com reply Store Fe 7 Due to manufacturer agreements not all U zel P du Search by part HO i nd ud um products are available in all geographic e number for fast D 4 ce A Eo Em fe PK Veces qoa areas and markets az results D oe ile aa eet eer a Prices in this catalog are current at the A CLE A Mur et unns publication date and are subject to change without notice UOHO W pue Mo 4 SPI OS sJouJuJeJboJdg pue SJa O43uO 10 eD1p Uy Je3161q OQ ot D gt a Ke LI N o S pue siapsoday Ad ualdyjy pue Ayajes uonsnquJo S AJLA SSADOId Illinois Indiana Missouri and lowa Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 www lesman com Phone 800 837 1700 262
47. included in Honeywell s DR45AH HTST and DR45AP pasteurization recorders To order the HTST dairy recorder choose model DR45AH __ For the pasteurization flow recorder choose model DR45AP__ For more specific information call Lesman 800 953 7626 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Honeywell Specifications Chart 12 diameter chart Thermal sensitive paper Stylus Life Capable of printing one chart per day for ten years Minimum Input Span Fully configurable within limits of selected range Input Impedance RTD 100 per lead max Sampling Rate 2 nputs 3 times sec 3 or 4 Inputs Once every 2 3 sec Span Step Response Time 6 seconds max without filtering Input Filter Single pole low pass selectable time constants off to 120 sec Indicators Channel PV display CH 1 2 3 or 4 Alarm status ALM 1 2 Con troller output OUT 1 or 2 Remote setpoint RSP Temperature unit F or C or Engineering units Controller mode A or MAN Digital Indication Accuracy 1 digit Digital Displays Vacuum fluorescent alphanumeric 6 digit display dedicated to process variable Alternate information displayed at setup 8 digit display shows key operating parameters Also provides configuration guidance Deviation Bargraph 21 segment color coded graph Green On Control Red Deviation to 10 PV
48. ions These can be tied to the relay or digital outputs to activate the user s external equipment Single Relay Output A separate relay alarm output at the rear of the unit can be set up as an alarm output Alarm Card Four or eight SPDT relay contacts 240V 8 I O or 16 I O 24 VDC Programmable alarm setpoints can be configured to activate up to 16 outputs Analog Output Two or four 0 20 or 4 20 mA outputs per card Digital Input Up to 12 digital inputs let you initiate through a dry contact closure selected recorder functions Pulse Counting Up to four frequency inputs per board are available to count signals up to 25 kHz max 2 cards Display Display 5 7 or 12 1 Color Active TFT with more than 256 000 colors makes it easy to interpret process data and take action Features intuitive bar charts digital values trends or customized displays A screen saver can be set to extend the life of the backlight Touch Screen Heavy duty durable touch screen provides easy data entry and rapid navigation though the menus Help Files Complete contextual help system can be accessed and visualized on the screen of the recorder Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Honeywell Lesman Instrument Company www lesman com sales lesman com Features Crystal Clear Display Minitrend GR
49. ital Inputs S Digital Inputs No Approvals UL Listing CSA Certification UL and CSA Approval No Certificates Cert of Conformance F3391 Cert of Calibration F3399 cert nd Restrictions Requires Pen 1 output Requires Pen 2 output __ _E S or r ce a ee CHART RECORDERS DR4301 DR4321 DR4311 DR4331 T q 241 T 928 00 1590 00 1180 00 1261 00 1315 00 1400 00 1590 00 1664 00 PID control Current Out 2 Alarm Out For On Off or time proportional control only one output can be an alarm Time proportional duplex requires both outputs G_ Customer must supply input actuation and range for each input Digital inputs only available with Pen 1 or Pen 2 outputs 4 20 mA retransmission output includes 2 outputs per pen for alarms Not available on FM Approved units Pen 1 Pen 2 F__ __ oe ea F _G__ Solids Flow and Motion Controllers and Programmers Digital Indicators ZO E S5 Og 2 ox vm cc C C Combustion Safety and Efficiency Process Valves uono w pue Mo 4 spilos sJouJuJeJboJd pue SJ9 O43u0 10 eD1p Uy e3161q I ot Y gt a LI Un oO S pue siapsoday Ad ualdyjy pue Ayajes uonsnquJo S AJLA SS2920Jg CHART L 242 RECORDERS Fax 630 595 2386 Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790
50. latile 256MB or 740MB Setup and screens Stored internally on non volatile memory Manual saving Data saved on USB memory stick saving period related to log rate number of pens totals and alarms Each pen is capable of its own storage rate Recycling mode Internal memory has FIFO first in first out capability where newest data overwrites the oldest Communication Ethernet 10 base T connector standard supports Modbus TCP FTP internet DHCP or fixed IP addressing Events User defined events are recorded and can be set to cause actions recording start stop digital inputs alarms totalizing actions timers bar codes Once an event has been caused it can produce a set of actions mark on chart relay outputs recording control acknowledge alarm trigger an event set clear relay screen change e mail a message or reset min max Each event marker can be recorded for analysis Alarm Setpoints Six per pen integral soft alarm setpoints announce selected out of limit conditions User can choose if alarm triggers a change in chart background color Can be set for High Low Deviation Latched alarms require operator acknowledgement Alarm damping 1 sec to 24 hours Hysteresis 100 pen scale Alarm can change the log rate on an affected pen Alarm Outputs Programmable alarm setpoints six per pen can be con figured to activate up to eight outputs 200 mS update rate 4 or 8 relay contacts SPDT 3A 240 VAC 3A 24 VAC DC 0 2A 2
51. mid ity 0 10096 and voltage current Transmitter Friendly An integral 24 VDC power supply and a 4 20 mA input allow operation of up to two transmitters Easy Setup English prompts and menus walk you through con figuration to simplify setup and reduce risk of improper program ming All configuration data are stored in nonvolatile memory for safekeeping in the event of a power failure Operator Interface Chart ranges can be set and reset in the field simply by keyboard input The keyboard serves as an integral auto matic manual station to provide bumpless transfer for controllers e Data Displayed Brilliantly Digital displays are read easily at a distance or in dim light and display all critical information At a Glance Processes Select displays for process variable set point deviation alarms automatic or manual control temperature units F C or engineering and setpoint program run hold Time Date Integral real time clock provides accurate timing for the recorder s time and date printing A 10 year life battery backup assures correct timing even when power fails Flow Totalizer An optional totalizer eliminates the need for additional integration hardware including a mechanical counter Pre programmed software calculates flow totalization Self Diagnostics Self diagnostics check critical operations and provide error messages that alert you to detected faults Tests are p
52. mited Modbus RTU RS485 Controllers 1 per Pen 1or2 2 4 20mA Pulse Output Autotune AccuTune Il AccuTune Il AccuTune Il Control Features On Off Duplex PD with Manual Reset Cascade Duplex Position Proportional Universal Output Cascade Duplex Position Proportional Universal Output Door NEMA 3 IP66 NEMA 3 NEMA 4X Door Optional Programmers 1 per Pen 4 Profiles 24 Segments Standard with Control 6 Profiles 36 Segments Sample Rate 0 3 Seconds 0 3 to 0 7 Seconds Software Programs SpecView SpecView Prosoft Added Functionality Prices Start at Approvals Timers One Totalizer per Pen 24 VDC Power Optional Two Line Display for Viewing PV Setpoint Control Output Deviation from Setpoint e Gh APPROVED Totalization of Both Channels Timers Setpoint Programming with Real Time Clock Auxiliary 4 20 mA Output Integral 24 VDC Power Supply Provides Loop Power for Up to Two Transmitters Cc amp G Q9 APPROVED Totalization on All Channels Timers Setpoint Programming Auxiliary 4 20 mA Output Math Functions Mass Flow BTU Fo Sterilization Message Printing Integral 24 VDC Power Supply Real Time Clock Up to 6 Relays HTST Dairy and Pasteurization Models Available Cc amp APPROVED Optional Functionality rada a i d input for Peer recorder See pages 98 105 Solids Flow and Motion Controllers and Programmers Digital Indicators
53. n be printed and signed by the appropriate person 50037651 501 328 00 to its design in particular the uniformity of Solids Flow and Motion Controllers and Programmers Digital Indicators ZO ru Su S5 Og pum ox v cc C O Combustion Safety and Efficiency Process Valves sJouJuJeJboJg SJO3e2Ipu e3161q pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I D t gt a Q Uu c l9 S Ad ualdyjy pue Ajajes uonsnquJo S AJLA SS DO1d RECORDER l L 256 SOFTWARE Illinois Indiana Missouri and lowa Lesman Instrument Company Wisconsin and Upper Peninsula Michigan Phone 800 953 7626 630 595 8400 www lesman com Phone 800 837 1700 262 923 1790 Fax 630 595 2386 sales lesman com Fax 262 923 1797 Honeywell Trendview Family Video Recorder Software Features o Wemdviewer TrendManagerPro TrendServer Pro Graphdataandprintcharts v 4 ExportdatausingCSVformatfiles Read archived data onPCSsintegralsource database Full configuration of all V5 recorders on PC Required for Events options 7 7 SININIS SININIS S RealtimedataacquisiiontoPC OOOO y Y SS OPSewr 000000 X Remote access to database password protected Audttoilmanagerwihfllusermaceabiy Password administration control permisos 7
54. ns for heat cool Optional Autotune selects optimum tuning parameters Digital Input Switch from automatic to manual control mode from direct to reverse controller action reset the limit controller or mark an event from remote location through two dry contact closures Alarm Output Ties soft alarms to two internal SPST relays to activate external equipment Chart Illumination Improves readability in low light areas Setpoint Ramp Soak Programming Lets you program and store 6 ramp and 6 soak segments Run or hold of program is key board or remote switch selectable HTST Pasteurization Enhancements Honeywell Truline can handle pasteurization processes based on flow and temperature DR45AH High Temperature Short Time HTST recorders monitor control and divert product based on temperature DR45AP pasteurization flow recorders monitor control and divert product based on flow rates The digital reference temperature measurement feature prints the actual Divert Temperature and Forward Flow Temperature beside the Divert Pen trace eliminating user error Since this feature is built into the DR4500 it saves on panel space and installation costs The DR45AP pasteurization flow recorder can also perform the functions of a differential pressure switch controlling the system back pressure to ensure that proper pressures are maintained in the pasteurizer No other single recorder controller provides the functions and features
55. nsin and Upper Peninsula Michigan PAPERLESS Phone 800 837 1700 262 923 1790 RECORDERS Choosing the Right Paperless Recorder 1700 29 000 ELST 2 087 51 22 25 15 UN 7 Ss eZtrend GR Minitrend GR Multitrend GR ee inputs Uptoi2inputChanels Upto 16 Input Channels Upto48 Input Channels Auxiliary Output 1 4 GB Internal 8GB External SD Card Ethernet RS485 Standard OPC Server Optional Displays Standard Screens Only 21 CFR Part 11 Password Protection Extended Security System Networking Ethernet Web Ready Analysis Software TrendManager Pro See page 256 Event Recording Instrument Depth Ethernet Standard OPC Server Optional Event Markers CER CEOS Pricing Starts At 1803 00 2730 00 4001 00 248 249 250 255 What makes Trendview different Fast Input Sampling Rates Universal input card s 20 mS scan rate per pen lets you direct what s happening in your process Enable fuzzy logging data storage and you ll have data compression surpassing any other available method Batch Recording Automatically graphs batch data Batch number data identification Purpose designed screens for easy use 32eventrecipes What is Fuzzy Logging A secure storage algorithm delivers a 10 1 compression ratio for 10times more stored data 10 times longer disk duration and increased resolution on fast changing process signals It includesaself teachingfunction
56. ompany www lesman com sales lesman com X Series GR Advanced Graphic Recorders Specifications Design Attributes Display Minitrend GR 5 7 digital color touchscreen LCD TFT QVGA 640 x 480 pixels resolution backlight lifetime to 55 000 hours Multitrend GR 12 1 digital color touchscreen LCD TFT SVGA 1024 x 768 pixels resolution backlight lifetime to 43 000 hours Screen Presets Screen Saver Set in minutes from 1 to 180 can dim the screen or switch off Brightness Adjustable 10 100 default at 80 Maximum luminosity 400 cd m2 Display Update Rate Display values updated every second Status Display A status bar at the top of the recorder s screen displays the real time icons of the recorder status time left and alarm active Communications Ethernet 10 100Base T with RJ45 connector supporting Modbus TCP FTP Internet DHCP or fixed IP address RS485 Modbus RTU up to 115200 baud rate Mathematics Add Subtract Multiply and Divide Free form scripting math option up to 100 characters free form math expression for each pen USB Ports USB host ports front and rear for data and setup transfers Keyboard or mouse barcode reader or external mass storage device Standard and Custom Screens Fully programmable display values in engi neering units Time date stamp on every division Standard screens display data digital reading bargraphs or combinations Custom screens created in Screen Designer software
57. or heat cool applications Uses two relay contacts with adjustable deadband split at 5096 controller output Output Limits 0 to 100 relay output 596 to 105 current Deadband 5 to 2596 time relay 0 to 25 on off duplex Hysteresis O to 10096 of PV span Case NEMA 3 molded foamed Noryl with gasketed door Pen Disposable fiber tip ink cartridge line length per cartridge more than 1000 ft One pen Purple Two pens Purple and red Chart 10 24 diameter 4 calibrated width standard preprinted markings Approval Bodies UL CSA FM approved limit controller model Options Alarm Output Two SPDT electromechanical relays solid state or open col lector outputs for alarm Relay contact ratings 5A 120 VAC or 2 5A 240 VAC resistive 50 VA 120 VAC or 240 VAC inductive Tuning PID tuning parameters of Gain or PB Rate Reset Sensor Burnout Selectable for none upscale or downscale Totalizer 1 per pen resettable with keypad or remote digital input Alarms Based on PV or deviation high low state Hysteresis 0 10096span Digital Inputs Two digital inputs dry contact Use for event recording reset totalizer timer switch to setpoint 2 switch to manual mode IA DR4301 0000 G0100 0000 0000 00 000 EO IA DR4311 0000 G0100 0000 0000 00 000 EO IA DR4302 0000 G0100 0000 0000 00 000 E0 IA DR4312 0000 G0100 0000 0000 00 000 EO 960 00 1212 00 1347 00 1622 00 Please note These devices are not field upgr
58. oserves as an integral automatic manual station to provide bumpless transfer for controllers On two pen models the HOLD key allows continuous display of one channel process variable while the recording action proceeds normally Microprocessor Controlled Recording Both the chart and pen are driven by microprocessor controlled step per motors for precise maintenance free operation Since chart speed is configurable you can easily alter it through the keypad no gear changing or additional motors required The microprocessor uses the chart range data and input data to determine proper pen position Input Processing Inputcan be one of many standardlow levelelectricalsignals Fortwo pen models a relative humidity wet dry bulb input is available using Pt100Q bulbs Each input is sampled three times per second Set the input type and range for hassle free changes in the field Easily expand or compress ranges within limits to meet your specific need You can also select upscale or downscale sensor break protection A digital filter with configurable time constants lets you apply input signal smoothing All nonlinear inputs are linearized using lookup tables This allows mixed actuations for two pen models to record on a linear chart Bypass linearization to record on a nonlinear chart The integral 24 VDC power supply and 4 20 mA input configuration allows direct operation with up to two transmitters without the need for any additional
59. ower 24 VDC Instrument Power 50 Hz Input Frequency Filter Value _1 0 00 60 Hz Input Frequency Filter Value _2 0 00 Memory 1GB Internal 8GB Front SD Card 3 2GB Internal 8GB Front SD Card 4 5 Security None 0 _ 0 00 Extended Security System 210 00 Fifty Credits Sixty Credits Seventy Five Credits 0 0 00 ED E 37 00 CE Mark IP55 NEMA 3 20 0 00 CE Mark IP66 NEMA 4X Appro CE UL CSA Approvals IP55 NEMA 3 vals CE UL CSA Approvals IP66 NEMA 4X CE FM Class 1 Div 2 IP66 NEMA 4X CE UL CSA FM CI 1 Dv2 IP66 NEMA 4X None Screen Designer TrendServer Pro AMS2750 D Report Generation Tool Software Screen Protector 5 Pack for Minitrend GR Storage 4GB Internal 8GB Front SD Card Ten Credits Ninety Nine Credits F3391 Certificate of Conformance Screen Protector 5 Pack for Multitrend GR 50037651 501 50017290 501 50017290 502 Restrictions a Requires a minimum of six inputs in Slot A c Not available with Case Mount V f Requires minimum of four inputs in Slot A g Requires inputs in all preceding slots Call Lesman for pricing and availability on signal connectors for use with individual analog inputs Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 PAPERLESS RECORDERS 255 V01 2015 Fax 262 923 1
60. rocess improvement The GR s touchscreen interface makes configuration and operation actions fast and simple Graphical icons and menu structure help the user easily understand how to view the various screens and review the data and other process information The Ethernet feature and compatible TrendServer Pro software pro vides plant wide connectivity of recorders so those who need to see the recorder s data can get easy access to it And the ability to have data in electronic format saves significant time and expense It s fast and easy to analyze the electronic data using the compatible software tools to create custom reports Above all paperless recorders eliminate the cost of consumables like pens and paper and the associated problems with tearing smudging running out of ink or paper mid batch paper jams and the costs associ ated with storing and retrieving the paper data when it s needed Honeywell X Series recorders help users with unique data acquisition problems Features like AMS2750 Process Recording provide documenta tion to show compliance to process specifications when being audited by NADCAP An Installation Qualification Operational Qualification IO ah 4j d 3A GR c4 4 xw oZ ing via web browser Independent chart and logging speeds Rapid review and replay of data at recorder CS CSA UL approvals NEMA AX IP66 enclosure option OQ protocol function helps pharmaceutical users with their 2
61. rument Company www lesman com L 248 sales lesman com eZtrend GR 5 7 un Video Recorder Features 5 7 digital color active TFT LCD with 320 x 240 pixel QVGA resolution Industrial rugged touchscreen with rapid navigation clear intuitive operation Up to 12 analog inputs up to 8 DI DO 4 pulse inputs optional via digital I O 10 100 Ethernet DHCP OPC FTP TCP IP web and E mail RS485 Modbus option Front USB port standard for keyboard mouse or storage drive On board solid state flash memory 256 MB or 740 MB Removable USB storage 21CFR Part 11 compliant password protection ESS extended security system Remote access advanced software data analysis at your PC plus remote view Honeywell eZtrend GR is a cost effective general service DIN size electronic data recorder that easily replaces 100mm paper strip chart recorder providing the ability to capture continuous and batch data electronically The data is recorded in secure digital format eliminating interpolation errors that can arise from transposing the data from a chart to a spreadsheet for necessary analysis The paperless solution also provides a graphical display unlike paper recorders which generally use either scales or digital formats for displaying process variables eZtrend GR reliably records electronic data from directly connected sensors or transmitters and displays it in a format that can be used for documentation of process conditions and p
62. s m de erre aril JAT Mir Lh Tiles e e 0 ete ee 7 60 Buylrecorderstandisuppliestonlinetatilesman com I tar Hut impor Lo rr ram Se eee uam a emma ro SS dermee Dmie Teom Be emeden mui Boim Po gemei o oap le cles s egal a eel be Y Wiles Run eae Site el eel CR LT EEG ley ie ee Piet fete aa Lae Dich n ur ERN ae UFT Chibi Le PaL Viel E Letom ol Le ay fag EIL LI cee Ea ond eed Teme sa oe Brai kia art yaa ijan oH paiia makai a mie i ey yeu Pir raii Ble d n Ti igli i etree eh piai i Tjera Ri fiie t7 recia CADS Mercedes rer Hina edil reire 127 Pale TP A e riar erem ril ee sp ed zm a ad hiris i Po aae a Pe ippa modas es ive mlhi uar ie eh le ei P irira ee ee ed a a Taai ma ee ees ad masa ee ah ey Wo ay t oom bevy oe ge E ate Ert Cd ee LE uic m UG oak a nias lon E mu aris Ux mtr iam mura PI toh Se hoe EL Pu ar fe de eg es aie n ad iraina ed er Qe gar pe d pom en cinj Ce eee be Dub hira Bik er a ee Sed LR ELE ed Se NTT am m n Bre BOSE AL eC US Poe fo ay peris Aa corneas a4 i Bua i iis Tm emus Co Riad POR ma Forge Fon Cina hun kim Pium Fam Fue DR TS 17 arg ar Di ee Paje LE mea siart a up i b com ha i amant LonCgerd unm munde Pgo ut d u nonim ar Bee Se L ba pem wr oar um eu pur eee hex FR pum Tees Lg DG comu pug cups rar Pe Ser ee saxa CE famil que ase pee a b Thari Baer Fi Walcema Lo Ere
63. sition 42 Pack of 6 c Not available with CE approval Phone 800 837 1700 262 923 1790 Fax 262 923 1797 V01 2015 Ordering Instructions Make one selection from each table section below Check the restric tion letters to be sure that the unit you have selected is available A finished catalog number looks like this DRASA1 0 w ktb O Model Selection Guide Catalog Avail Description Number ability DR45A1 4 1653 00 DR45A2 2142 00 Single Pen DR4500 12 Classic Recorder Dual Pen DR4500 12 Classic Recorder T C RTD mV 0 5 VDC 4 20 mA Radiamatic 0 10 VDC None T C RTD mV 0 5 VDC 4 20 mA Radiamatic 0 10 VDC Channel None 2 Out Control Output 2 None Auxiliary 4 20 mA Output None Alarms 2 Alarms 2 Digital Inputs 1 Alarm 1 Timer Output 2 Digital Input Totali None zation Totalization on Input 1 Totalization on Inputs 1 and 2 Gray Door with Glass Window Gray Door with Acrylic Window Blue Door with Glass Window Blue Door with Acrylic Window Stainless Steel Door Glass Window Stainless Steel Door Acrylic Window NEMAAX Door with Glass Window NEMAAX Door with Acrylic Window Standard Door Latch No Lock Door Lock Keyed Latch DUWNAU OC None CE Approved CSA Certification CE Approved CE Mark FM Approval CE UL FM and CSA Approved UL Listing CSA Approval FM Approved UL Listing FM and CSA Approval None Customer ID Tag 30 Character Max F33
64. stem ESS option extends these features to include time out of password entry password expiration and traceability of user actions ESS is compatible with the requirements of FDA regula tion 21CFR part 11 for pharmaceutical use Pressure a su r 10E oe 62 19 cc PIU 5 pis NL 88 1 LM F foal l LI E T pe gl a i M mop 66 097 Si 0 20 a P 1 8 80 oO 30 0 79 9 Ser Hrsaaaars wnr rur HI Temes T Eun a LH Ld Power 100 08 34 15 b 1 97 3 Horizontal Trends Ep bi Fo ELY I cheno scarey ressenrs b mma ertical Bars men aa a mue wire Panel Meter w Vertical Bars 3 Vertical Trends PA Horzontal Bars 6 Horizontal Bars Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Specifications Accuracy 0 1 or 0 2 full scale depending oninputtype Foracomplete input actuation table see the X Series advanced recorders on page 104 Inputs 3 6 or 12 analog input channels Types mv V mA with external shunt provided standard thermocouple RTD and Ohms Resolution 0 001596 16 bit ADC Display 5 7 color LCD with touchscreen QVGA 320 x 240 pixels resolu tion Touchscreen life One million touches Data Storage Local mass storage options USB memory key up to 2GB USB hard drive up to 120 GB Internal data buffer Non vo
65. t sampling rate is dependent on actuation type All Inputs 100mS 10Hz 200 mS 5Hz 500 mS 2Hz Fast Sampling 20 mS 50Hz for mA mV and volts only Input Sampling Method Sample Average Min Max can be set indepen dently per pen Scales Linear Logarithmic Linear 999999 to 999999 Decimal Automatic or programmable Engineering units user definable First channel in Screen Layout determines display chart scale Logarithmic 1 to 99 decades Input Isolation 300VAC channel to channel channel to ground Noise Rejection at 50 60Hz 2 Common Mode 2 5 and 10Hz 120dB Normal Mode 2Hz 85dB 5Hz 80dB 10Hz 48dB Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Instrument Company www lesman com sales lesman com Honeywell Logging Method Sample Average Min Max Can be set independently per pen Logging Types Continuous Fuzzy Logging Rate 20 msec to 4 days per pen Fuzzy Logging Secure data storage technique that delivers data compres sion ratio of 100 1 or more Self teaching storing the data at a variable rate to match the process Options Pulse Input 4 isolated inputs per board frequency 1Hz to 25kHz updated once per sec Input Low lt 1V High gt 4V to 50V or Volt free input Low short circuit High open circuit Alarm Outputs Programmable alarm setpoints 6 per pen can be configured to activate up to 16 outputs Update rate
66. table section below Follow the availability column down and check any notes to be sure the unit you need is available A finished catalog number looks like this IVEZODe 0 0 o o9 _ 000 Model Selection Guide Catalog Avail Description Number ability eZtrend QXe Advanced Paperless Recorder TVEZGR wT 1803 00 Analog 3 Analog Inputs IN1 IN3 3 0 00 Inputs 6 Analog Inputs IN1 IN6 6 309 00 Expansion None _0 0 00 Card Board for Option Cards _1 82 00 Analog None 0 00 Input Card 6 Analog Inputs IN9 IN14 3 C 618 00 None 4 Relay Outputs 8 Relay 2 Digital IN 6 Fixed Out 2 Configurable DI DO 8 ee DI 24V Out Input Freq Filter Value 1GB Internal 8GB Front SD Card 2GB Internal 8GB Front SD Card 4GB Internal 8GB Front SD Card 10 Credits 20 Credits 30 Credits 50 Credits 331 00 601 00 756 00 1103 00 1239 00 1313 00 1444 00 Case Panel Mount 0 00 Mount Panel Mount with Rear Cover 12 79 00 User Product CD and Trendviewer 0 0 00 Documents Print Manual Trendviewer CD NEN 21 00 None 0 00 Tagging Stainless Steel Tag ___ 10 37 00 CE Mark IP54 NEMA 3 0 00 Standards CE Mark IP66 NEMA 4X 53 00 CE UL CSA IP66 NEMA 4X Certificates None F3391 Cert of Conformance F3399 Custom Calibration Test F3391 and F3399 Certificates None Software TrendManager Pro TrendServer Pro TrendServer Pro with OPC Firmware Credits 60 Credits 75 Credits 99 Credits 5 Discrete outpu
67. to store dataata variable ratethat matchesthe monitored process ptm NC E I ae euo iio DUA MA SNA WI WA a NI 11 Ex Zi saw ae CEOO LS 250 255 How Secure is the Data Process data and configuration files are en crypted encoded and set up with checksums to prevent undetected changes And because configuration files are stored with the process data you ll know exactly how the recorder was configured and when data was recorded Continuous Recording Data sampling up to 50 readings second Detailed event reports Networkable via RS485 or Ethernet Fuzzy Logging data compression technique Regulatory Recording Redundant data storage Validates to regulatory requirements Meets FDA guidelines for electronic data submittals Event configuration audit trail Secure data encryption Solids Flow and Motion Controllers and Programmers Digital Indicators em ZO m E dm sg um ox S cc C m Combustion Safety and Efficiency Process Valves sJouJuJeJboJdg SJO3e2Ipu e3161q pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I ot Y gt a LI Uu c oO S Ad ualdyjy pue Ayajes uonsnquJo S AJLA SS220Jd PAPERLESS RECORDERS Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790 Fax 262 923 1797 Honeywell Illinois Indiana Missouri and lowa Phone 800 953 7626 630 595 8400 Fax 630 595 2386 Lesman Inst
68. ts are lowlevel 1 Amp 24VDC non inductive loads Any channel on the 8 discrete I O card can be used as a digital input if NOT used as alarm output Up to 4 channels can be used as pulse input up to 1 KHz 7 Factory set to this frequency but can be changed in the setup menu 10 Customer must supply tagging information Up to 3 lines 22 characters ea 11 Calibration test reports and certificates require specific range and input actua tion data from customer Call Lesman for Form F3399 13 Software packages can be ordered separately See page 256 Solids Flow and Motion Recorders and Digital Indicators Controllers and Efficiency Data Acquisition and Programmers Combustion Safety Process Valves sJouJuJeJboJdg SJO3e2Ipu e3161q pue sJ9 OJ3u0D uono A pue MO Spi os pue siapsoday I D ot D gt a LI Uu c oO S Ad ualdyjy pue Ayajes uonsnquJo S AJLA SS220Jd PAPERLESS RECORDERS L 250 Fax 630 595 2386 X Series GR Advanced Graphic Recorders RA Am Data Storage On board non volatile memory up to 3 7GB Removable SD Flash and USB storage No moving parts all solid state data storage e Stringent Security for Total Data integrity Password Protection 21CFR Part 11 Compliant Extended Security System ESS Wire seal provision Inputs and Outputs Soft Alarms Six software alarms per pen are easily set up to display and record selected out of limit condit
69. ts over 0 21 mA Accuracy 0 2 full scale Temperature stability 0 03 full scale per C Controller Output Types On Off or Time Proportional One SPST electromechanical relay direct or reverse action N O or N C contact selectable On Off or Time Proportional Duplex 3 Position Step Control Two SPST electromechanical relays direct or reverse action N O or N C contact selectable Current Proportional 20 mADC max into 0 1000Q grounded or non grounded load Output range can be set between 4 and 20 mA direct or reverse action 10 bit resolution 0 5 full scale accuracy Position Proportional Two SPST electromechanical relays operate motor with 100 to 1000Q slidewire Current Time or Time Current Duplex Variation of time propor tional duplex for heat cool use Time proportional output SPST electromechanical relay 4 4 mSec resolution 1 120 sec cycle time Rated 5A 120 VAC or 2 5A 240 VAC resistive 50VA 120 240 VAC inductive Current proportional output is 4 20 mA signal fed into 0 1000Q grounded or non grounded load operational over 50 or 10096 range 10 bit resolution 0 596 full scale accuracy Protect your instrumentation Need electrical surge protection Phoenix Contact offers a full line of electrical surge protection for AC and DC powered control lers recorders and loop power supplies Call for pricing Wisconsin and Upper Peninsula Michigan Pen Purple Position 1 mut of T Refills Red Po
70. value must be as signed to a pen for display and storage Multiple totalizations Math option are possible by using extra pens Reset may be manual or programmed Totalization values are ten digits plus exponent Each pen can be totalized according to Fo or Po Sterilization function at 250 F Standard reference temperature and thermal resistance Z Value are fully adjustable values of X Y W and V Start temp Reference temp and Z factor are all user defined allowing support for many different types of Sterilization applications Identification Optional customer ID Tagging 3 lines 22 characters each Batch Monitoring with a Paperless Recorder Creating Batch Markers Users start stop pause or resume from touchscreen push buttons Batch capabilities Batch actions Start or end of batch batch pause resume or abort Batch identifiers Four batch tag fields can be used to include batch name batch description lot number user ID and comments fields can be custom named View batches At database on PC or recorder using Batch icon Filter events batches By batch name date time or event type Export batch data Export from TrendManager Pro to Excel on your choice of single or multiple spreadsheets This makes analysis and graphing of data in Excel quicker and easier reducing the time to manually organize data into a single spreadsheet Wisconsin and Upper Peninsula Michigan Phone 800 837 1700 262 923 1790
71. with up to six survey setpoints and can support up to 40 inputs Survey data points are recorded every two minutes into a separated data file that is used by the TUS report generator to create a temperature survey report Currently the TUS capability works only on single zone thermal processing equipment What do I need to get AMD TUS reports on my PC Here s what you need to run AMS themocouple uniformity surveys on a GR series recorder and generate TUS reports from a PC 10firmware credits for AMS2750 TUS Sufficient credits for additional pens AMS2750D PC Report Generation Tool P N 50037651 501 R Rear cover option on recorder s part number or retrofit rear cover with P N 50005458 501 TrendManager or TrendServer Pro software Three firmware credits optional applied to Report for abbreviated TUS Report on recorder not PC version DataforaTUSreportisloggedtotheTUS export memory nottherecorder s log memory To export TUS data to a TrendManager or TrendServer Pro database you ll need additional pens for each temperature pen AMS2750D Report Generation Software The AMS2750D Report GenerationTool is PC software that produces reports from your recorder s data results Report tool uses a special data file gen erated by the recorder plus user entered data related to the survey furnace instru mentation and calibration information to generate the survey report in Adobe PDF format This document canthe
Download Pdf Manuals
Related Search
Related Contents
MANUEL D`UTILISATION Le système de racles à chambre Manuel d`utilisation USER`S MANUAL USER`S MANUAL Copyright © All rights reserved.
Failed to retrieve file