1. I as a5 as Oi Once the UPS is mounted please follow the installation instructions in the Smart UPS Quick Reference Guide Operating Instructions on Battery During on battery operation the yellow on battery LED illuminates and the UPS sounds an audible alarm consisting of 4 beeps every 30 seconds The alarm stops when the UPS returns to on line operation 9 Overload When loads exceed the UPS s capacity the red overload LED illuminates and the UPS emits a sustained tone The alarm remains on until the overload is removed Disconnect nonessential load equipment from the UPS to eliminate the overload If the overload is severe the input circuit breaker may trip the resettable center plunger of the circuit breaker pops out Disconnect nonessential load equipment from the UPS to eliminate the overload and press the plunger back in If there is AC power and the circuit breaker does not trip during overload the loads are still powered If the circuit breaker trips or the UPS attempts to transfer to battery the loads power will be shut off Turn the UPS off then back on to power the loads Replace Battery If the battery pack fails a self test the UPS emits short beeps for one minute and the red replace battery LED illuminates The UPS repeats the alarm every five hours Perform the self test procedure to confirm replace battery conditions The alarm stops w
2. Place ate Stephen A Lee Regulatory Compliance Engineer Serial Numbers We the undersigned hereby declare that the equipmen Ahab Galway Ireland Place ate Ray S Ballard Managing Director Europe
3. the UPS for at least 8 hours Cover the UPS and store it lying flat in a cool dry location with its battery pack fully charged Extended Storage At 15 to 30 UC 5 to 86 F charge the UPS s battery pack every 6 months At 30 to 45 0C 86 to 113 UF charge the UPS s battery pack every 3 months Replacing the Battery Pack This UPS has an easy to replace hot swappable battery pack Note Please read the cautions in the APC Safety Guide Replacement Batteries See your dealer or call the number in this manual for information on replacement battery pack kits For 250 models order RBC17 For 450 models order RBC18 Battery Pack Replacement Procedure Battery pack replacement is a safe procedure isolated from electrical hazards You may leave the UPS and loads on for the following procedure Notes Once the battery pack is disconnected the loads are not protected from power outages Be careful removing the batteries they are heavy Small sparks at the battery connectors are normal during connection Specifications 250 VA 450 VA a eee utility during brownout Soe ee shutdown on overload Lc sha cycles and ambient temperature 5 to 95 non condensing Size H xW x D 4 5 x 44 5 x 33 cm 1 75 x 17 5 x 13 0 in 11 82 Weight net shipping 8 41 10 45 kg 9 77 11 82 kg 18 5 23 Ibs 21 5 26 Ibs Safety and approval
4. turn clockwise and replace the front cover LY N 10 Batteries must be recycled Deliver the battery to an appropriate recycling facility or ship it to the supplier in the new battery s packing material See the new battery instructions for more information If the UPS requires service do not return it to the dealer Follow these steps 1 Use the Troubleshooting section of the Quick Reference Guide to eliminate common problems 2 Verify that no circuit breakers are tripped A tripped circuit breaker is the most common UPS problem 3 If the problem persists call customer service or visit the APC Internet Website www apcc com 4 Note the model number of the UPS the serial number and the date purchased A technician will ask you to describe the problem and try to solve it over the phone if possible If this is not possible the technician will issue a Return Merchandise Authorization Number RMA 5 If the UPS is under warranty repairs are free If not there is a repair charge 6 Disconnect the batteries before packing the UPS 7 Pack the UPS in its original packaging If the original packing is not available ask customer service about obtaining a new set 8 Pack the UPS properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty 9 Include a letter with your name RMA address copy of the sales receipt description of the trouble your daytime p
5. APC www apcc com SS APC PowerStack 250 450 Uninterruptible Power Supply User s Manual 990 5020 Revision 1 10 98 CUELA To obtain warranty coverage please fill out and return the warranty registration card now Inspection Inspect the APC PowerStack 250 450 Uninterruptible Power Supply UPS upon receipt Notify the carrier and dealer if there is damage The packaging is recyclable save it for reuse or dispose of it properly Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the warranty Rack Mounting The UPS comes with standard 46 5 cm 19 rack mount brackets It is supplied with four 4 screws to attach the mounting brackets ears to the chassis Select a rack location with adequate air flow that is free from excessive dust Ensure that the air vents on the sides of the UPS are not blocked Do not operate the UPS where temperature or humidity are outside the limits in the Specifications section of this manual Switch On Switch Off a ee I ao O l Owin the UPS plugged in press and release the on off test button to supply power to the loads a amp O KI The loads are immediately powered while the UPS performs a self test Press and release the button again to turn off power to the loads It may be convenient to use the UPS as a master on off switch for the protected equipment Ay The green on line
6. LED illuminates when the UPS is supplying utility power to the loads Self test The UPS performs a self test automatically when turned on and every two weeks thereafter Automatic self test eases maintenance requirements by eliminating the need for periodic manual self tests During the self test the UPS briefly powers the loads on battery If the UPS passes the self test it returns to on line operation If the UPS turns off during the self test and emits a fading tone the batteries are not connected properly The loads are not affected by a failed test Recharge the battery pack overnight and perform the self test again If the replace battery LED is still on replace the battery pack using the Replacing the Battery Pack procedure Wall Mounting The brackets on the UPS can be rotated 90 U for wall mounting Remove the screws rotate the brackets and insert the screws in the appropriate holes Wall mount the unit with the controls a towards or at the top not at the bottom of the unit p 0 eBo 0 agga Be The illustrations above show the proper positions for wall mounting the unit Warning Do not mount the unit X X on the wall as shown N in the illustrations at O left Doing so could Be result in a safety hazard Rear View
7. hen the battery pack passes the self test English Desktop Use This UPS is provided with four adhesive backed rubber feet for desktop use Attach the feet to the bottom of the unit and remove the ears to use it on a desktop The recommended placement of the feet is shown by a small on the bottom corners of the unit ogo Computer Interface Port The interface port is used for communicating with the UPS See enclosed documentation for details LJ Charge the battery pack The UPS charges its battery pack whenever it is connected to utility power The battery pack will charge fully during the first 4 hours of normal operation Do not expect full battery back up runtime during this initial charge period Low Battery When the UPS is operating on battery and the energy reserve of the battery pack runs low the UPS beeps continuously until the UPS shuts down from battery pack exhaustion or returns to on line operation if the utility power returns before the battery pack is exhausted Cold Start Note Cold start is not a normal operating condition When the UPS is off and there is no utility power it is possible to cold start the UPS to power the loads from the UPS s battery pack l press and hold the on off test button until the UPS emits a constant tone Release the on off test button during the tone to start the UPS Storage Conditions Before storing charge
8. hone number and a check if necessary 10 Mark the RMA on the outside of the package 11 Return the UPS by insured prepaid carrier to the address given to you by Customer Service North amp Latin America APC APC 132 Fairgrounds Road Ballybritt Business Park West Kingston Rhode Island 02892 Galway Ireland 1800 702000 USA Toll free within the Republic of Ireland only Europe 1 800 800 4APC 1 401 789 5735 E Mail E Mail North America apctech apcc com Europe apceurtech apcc com Latin America apctchla apcc com Declaration of Conformity Application of Council Directives 89 336 EEC 73 23 EEC 92 31 EEC 93 68 EEC 91 157 EEC Standards to Which Conformity Declared ENS55022 EN50082 1 EN50091 EN60950 Manufacturer s Name and Address American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA or American Power Conversion A P C b v Ballybritt Business Park Galway Ireland or American Power Conversion Phillipines Second Street Cavite EPZA Roserio Cavite Phillipines American Power Conversion A P C b v Ballybritt Business Park Galway Ireland Uninterruptible Power Supply Importer s Name and Address Type of Equipment Model Numbers PowerStack Models250 and 450 BayStack Model UPS45 X9801 000 0000 X9899 999 9999 X9901 000 0000 X9999 999 9999 Years of Manufacture 1998 1999 Note Where X B O W or D A above directives dtephen a AL Billerica MA
9. s VDE licensed to EN50091 and EN60950 EMC certification EN55022 Electromagnetic Immunity IEC 801 2 Level IV 801 3 Level III 801 4 Level IV User adjustable through PowerChutel plus see software documentation LEDs and Audible Alarms a oad shutdown short circuit attery while k O O O O O O Transformer failure i attery Ce a EF a 7 a Si verl utpu Ow Battery disconnected in self test a Same ERORCHOGUOOCE EA eal EA EA e 1 Reach into the finger pull and remove the front cover 2 Usea flat blade screwdriver to turn the two battery door screws 1 4 turn counterclockwise open the door 3 Grasp the clear plastic tab and gently pull the battery pack out of the UPS until the battery connector is visible 9 S K Si Warning Do not force the battery pack out This may damage internal wiring 4 gt 5 Slide the battery pack out of the UPS 6 Slide the new battery pack three fourths of the way into the UPS 7 Connect the battery connector attached to the unit to the connector attached to the new battery pack Disconnect the battery connector by gripping both sides of the connector and firmly pulling them apart 8 Push the battery pack in as far as it will go There are stops in the back to prevent it from going too far 9 Close the battery door turn the battery compartment screws