1. MARKS U MARKS USA 365 Bayview Ave Amityville NY 11701 631 225 5400 1 800 526 0233 Fax 631 225 6136 www marksusa com Congratulations you have just purchased the i Qwik LITE Series lockset from Marks USA This lockset designed for easy installation will provide years WWMARKSUSA of reliable service when properly installed and maintained 365 Bayview Ave Amityville NY 11701 This manual is designed to act as a guide through the many features amp functions of your i Qwik LITE Series Stand Alone Access Control System LIVE TECH SUPPORT 8am 8pm EST Mon Fri Please take the time to read it thoroughly and follow the instructions carefully Toll Free 800 526 0233 so that your experience will be positive and trouble free In NY 631 225 5400 Fax 631 225 6136 Marks USA would like to thank you for selecting the i Qwik LITE Series for your E mail techsupport amp marksusa com access control needs For more information about the i Qwik Line i Que series the Complete Marks USA Product line templates amp manuals visit our website www marksusa com Table of Contents Before You Start Important Definitions asvvvvvevavavaenannrnrnenavnrarnavavarnennvarkrnananarnennnnsnrnennsnskenen Page i Important a aan Page 1 LED INdiCators saker wasn ents veps Subd sty as dele my tesla alta A Meal anda alene ga nt na St nia a Page 1 Create Master Code ni seems h r drain odde een dansken a t
2. ECK STATUS This function manually checks the battery status of the i Qwik LITE The LED on the keypad will display visual indicator ms 4 7 mn Green Green Two green LED flashes indicate full power 5 25 volts and above Yellow Yellow Two yellow LED flashes 5 25 to 4 75 volts Yellow Red Yellow then red LED flashes 4 75 to 4 37 volts Red Red Two red flashes indicates below 4 37 volts Batteries need to be changed NOTE IF THE VOLTAGE OF THE BATTERIES FALLS TO 4 2v DC THE i Qwik LITE WILL BEEP EVERY HOUR INDICATING LOW BATTERY STATUS Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 2009 Marks USA BATTERY INFORMATION THE i QWIK LITE IS SHIPPED WITH 4 AA ALKALINE BATTERIES The life span of the batteries has been tested in two different ways The first test was performed to see how many operations could be performed repeatedly before a failure The test averaged 150 thousand operations The second test was performed over time for normal operations This test revealed that the i Qwik LITE batteries would last approximately 4 years at 80 90 thousand operations Using the factory settings the lockset is set for optimized power usage CHANGE THE BATTERIES The batteries should not be disconnected longer than 10 minutes or there is a risk of affecting the lock s memory IT IS RECOMMENDED TO USE ONLY ALKALINE BATTERIES The alkaline battery has a gradual curve in the drop off voltage Th
3. EUROPEAN DATE FORMAT SET DD MM YY 0 ZERO DOUBLE CODE ENTRY For higher security the lock can be set to require that two User codes be entered before access is granted SINGLE CODE mews 4 33 0 DOUBLE CODE ememsrencooe fx Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 O 2009 Marks USA PRIVACY MODE SECRETARY MODE Privacy Mode Secretary Mode Secretary Mode is default An i Qwik LITE with the Privacy Mode option will have a button installed on the inside housing When the button is pressed it will block out keypad entries except User Codes from groups 01 03 When the inside lever is pressed the request to exit switch will reset the keypad back to normal operating mode PRIVACY MODE e a e Tr SECRETARY MODE DISABLE ENABLE THREE STRIKE LOCKOUT The lock responds to three consecutive incorrect codes by displaying a red light and shutting down the keypad for 20 seconds Subsequent attempts with an incorrect code will increase the time to 40 seconds maximum Disabling this feature allows an unlimited number of incorrect codes to be entered without a lockout DISABLE mums e e ENABLE emsrencoos fija CLEAR MEMORY If it becomes necessary to reset the memory of the i Qwik LITE there are two options other than the Full Reset option DELETE ALL USERS amp SCHEDULES DELETE ONLY SCHEDULES omme e e Je se BATTERY CH
4. ITE and the Exit Device Interface IQ7LITE will not have the motor leads These leads will be connected inside the front trim by the factory RESET THE LOCK Reset The i Qwik LITE Back To Factory Default Open battery cover top of housing on inside of door Black e Disconnect the batteries e Locate the Yellow and Black cable behind battery pack e Insert both ends of the reset wire or paper clip into the holes of the connector on the yellow and black cable e With the reset wire in place reconnect the batteries The LED will go GREEN e Press the key The LED will go RED and then back to GREEN Remove the reset wire SY e The lock is now reset Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 2009 Marks USA Yellow For more information about the i Qwik Line the i Que series the complete Marks USA product line templates and manuals visit our website www marksusa com Distributed by For i Qwik i Que Tech Support Call Toll Free 800 526 0233 In N Y 631 225 e 5400 Fax 631 225 6136 LIVE TECH SUPPORT 8am to 8pm EST Mon Fri Email techsupport marksusa com TMARKSUSA IP101 IQWIKLITE 03 09 2009 MARKS USA
5. NATOR OFF mmm ro Jr TERMINATOR ON mmm s 1 x NOTE TO ENTER PROGRAM MODE WITH TERMINATOR OFF YOU MUST FIRST PRESS THE KEY BEFORE THE MASTER CODE Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 2009 Marks USA MANUAL PASSAGE MODE This function puts the lock in an unlocked state granting free egress no code required to all Users until the lock is returned to the locked state The lock will return to the locked state at midnight This function requires that the time be set see Set Time below ENABLE mews 90 fr fr DISABLE mews 90 0 TEMPORARY USER SCHEDULE This function allows you to restrict an existing Users access by a date range Temporary User Schedules do not delete and must be maintained or access repeats annually This function requires setting the date in the lockset see Set Date below Enter MASTER CODE MMDD MMDD Start Date End Date SET TIME This function will set the time HHMM Time is set in 24 hour format Example 3 30pm 1530 Enter MASTER CODE Daylight savings time is enabled by default To disable daylight savings add a 0 zero at the end of the time entry Example 3 30pm 15300 SET DATE This function will set the Month Day and Year There are 2 formats available Standard default MM DD YY or European DD MM YY io WATE Ce a ee DE NOTE FOR
6. S Enter Master Code User ID and PIN the key 01 the key the User ID you wish to delete the key 0 and the key twice DELETE USER CODE Enter MASTER CODE User ID to be Deleted Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 O 2009 Marks USA PIN ONLY ENTRY The PIN Only mode will shorten the code required to open the lock ENABLE PIN TO OPEN LOCK ememastencone 92 0 DISABLE USER ID amp PIN TO OPEN LOCK exeasrencooe 2 x 1 CHANGE USER PIN This function gives users the ability to change their PIN User must know their User ID amp PIN to perform this function Enter UID amp PIN er ED New PIN Verify PIN DEFINE OPEN TIME This function will adjust the amount of time that the lock will stay unlocked after a valid User code has been entered The open time can be set from 1 to 9 seconds Default setting is 3 seconds od 9 m ne JJ LOCK AUDIO When the audio is set to ON the lock will beep with each key pressed On by default AUDIO OFF jemmsrencooe at x o AUDIO ON jemmsrencove ae x 1 TERMINATOR ON OFF This function will switch the sk Terminator On or Off Selecting off automatically sets lock to PIN Only mode To gain access with Terminator Off simply enter your PIN code With Terminator On you are required to enter sk after your code TERMI
7. bled for 40 seconds This is indicated by a solid red light LED INDICATING RED PROGRAMMING MODE 1 Denotes incorrect entry and vacates programming mode 2 Programming mode vacated if no key entry within 5 seconds CREATE MASTER CODE This code is required to perform all programming functions The number of digits used for the User ID and PIN of each additional user must be the same as the Master Code Enter 9991234 ee eens User ID PIN User ID and PIN followed by k will open the lock GROUPS ALL USERS MUST BE ASSIGNED TO A GROUP Users in the same group will have the same access rights Each group is assigned a 2 digit group number from 02 to 99 The Master Code is automatically assigned to group 01 and has full programming rights GROUPS 02 08 Management groups with 24 7 access GROUP 09 Group that allows the lock to be placed in passage mode when the code is entered The lockset will re lock when code is entered again or at midnight of that day GROUPS 10 99 No programming rights They may however change their own PIN See Change User PIN on page 2 TO ADD USERS Enter Master Code User ID and PIN the key 01 the key the User ID you wish to add the key the 2 digit group number the key the new PIN and the key twice ADD USER CODE Enter MASTER CODE User ID PIN User ID and PIN followed by will open the lock TO DELETE USER
8. g ds Page 1 GOUDSE avait aired edna b bee nede kake dio TE EE ER RPR Page 1 TO AGG USES sn eee l ii bn EG Ree moa Rhema Page 1 TO Delete USES kung eee ua a ENE BON da EN a av a aaa ann Page 1 PIN ONIV EN a ass a an Ad kA A a a aa ar ri Page 2 Change WSO PIN us sere NE AG OE GER RE VN ane aoe dake Page 2 Deine Open IMG runke usann asec te ta go tts bk did egen a land ale Ree ap ea Page 2 LOGKAU IO se ie ne dia aout be eda fe ka Aer Page 2 Teminato OM M sic tage delet ais ra sce eects ene ne Page 2 Manual Passage Mode xsnv eG AANA pe HER HOMERS a nae ae daa Page 3 Temporary User Schedule LLssmaan senare aie Wa naan ven Page 3 SEL TIME ua te tamales eee 0 mi a td Page 3 Se DA SS Page 3 Double Code EMNE p ran a ce aurea sete fader ek ek pin an aa AEE Page 3 Privacy Mode Secr lary M d sauarnnestsseai snap GE EE anneks sete eeb eaten tami aad Page 4 Disable Enable Three Strike Lockout 0 0 EEEE EEEE EEEE Page 4 Cleat Memory eles atri a na a EA aameee a Page 4 Baten CHECK Status Laud NN re Page 4 Battery N RR BNA ae ALL AG SIKRE AE AGS Eda Page 5 Connection Diagram 00 000 ns ns Page 5 Reset THE Lock air ain sk a a ia Ga a A Sa a Page 5 BEFORE YOU START BEFORE YOU START BEFORE YOU START IMPORTANT DEFINITIONS FACTORY CODE 9991234 This code is only used to initialize the lock after reset This code must be entered to set the Master Code After the Master Code is set the Fac
9. is curve determines the power settings for the two stages of battery warnings and the Fail Secure settings A lithium battery differs from an alkaline battery in the life cycle of the battery cell A lithium battery has a very sharp drop off voltage going from fully charged to a dead cell quickly This makes monitoring the voltage settings impossible TWO STAGE LOW BATTERY WARNING The i Qwik LITE has a two stage low battery warning The first warning stage will add a double beep and Red LED when the user enters their code The second warning stage will be a double beep every hour BATTERIES SHOULD BE CHANGED IMMEDIATELY Double beeps will occur until the batteries fail CONNECTION DIAGRAM Secretary s Button Orange amp Black This can be wired to a Momentary Normally Open NO switch When pressed lock will open for the set amount CableGard of time Button NOT Included Blue and Black A OO Request to Exit Switch Factory Installed Option Reset Key Switch Black and Yellow A Factory Installed Option This option will monitor of a key is used to open a lock For Resetting the i Qwik see below Power RED and Black 6 Volts DC Connects to the supplied battery pack 3 Red and Black Motor Cable Red and Gray lines to the gi motor connector POR Cylindrical Model shown IQ1LITE Please Note The Mortise IQ2L
10. tory Code will no longer be valid until lock is reset The Factory Code will not open the lock USER IDENTIFICATION NUMBER UID A unique 3 digit number assigned to each User PERSONAL IDENTIFICATION NUMBER PIN A combination of 3 alphanumeric characters Letters or numbers may be used multiple times to increase the total number of combinations MASTER CODE This code is required in order to perform all programming functions The Master Code replaces the Factory Code This code will open the lock USER CODE A combination of User ID and PIN Marks USA www marksusa com 631 225 5400 800 526 0233 Fax 631 225 6136 2009 Marks USA IMPORTANT KEYS TERMINATOR KEY 2k Acts like the Enter key on a computer and is used to confirm entries on the keypad PROGRAMMING KEY After a valid Master Code is entered this key is depressed to enter the programming mode NOTE At the end of any programming series replace the last with a to return to function number input This allows the programmer to perform multiple functions without having to re enter the Master Code for each function LED INDICATOR LED INDICATING GREEN NORMAL MODE 1 Denotes lock enabled to open Will flash green after valid entry and terminator key LED INDICATING RED NORMAL MODE 1 Denotes a wrong code entry 2 Three consecutive wrong entries will disable keypad for 20 seconds If another wrong code is entered the keypad is disa
Download Pdf Manuals
Related Search
Related Contents
Samsung NX300 (18-55 mm) Kasutusjuhend GPS/GPRS车载终端 MPIP MERCURY - Batribike Ragalta RCA-040 food storage container User Manual - The Source wash filter register your dyson 2 year guarantee today Da-Lite Designer Cinema 52" x 92", HDTV, Matte White Severin CP 3542 全車 - Out-Club.ru F.A.Q. 取扱説明書 - オークセール Copyright © All rights reserved.