Installation Guide OCTOPUS 8M/16M/24M Train
Contents
1. OCTOPUS 24M 2FX OCTOPUS 8M 16M 24M 18 Release 07 2008 Ground The chassis is grounded via a separate ground nut M3 L Use toothed locking washers for a good electrical connection Note The shielding ground of the connectable twisted pair lines is connected to the chassis as a conductor 2 1 4 Connecting the power supply startup procedure Mount the connector for the supply voltage and the signal contact on the front of the device By connecting the supply voltage at the connector you start the operation of the device 2 1 5 Connecting the data lines You can connect terminal devices and other segments at the ports of the device via twisted pair cables 10 100 Mbit s twisted pair connection 10 100 Mbit s ports enable the connection of terminal devices or inde pendent network segments in compliance with the IEEE 802 3 100BASE TX 10BASE T standards These ports support autonegotiation autopolarity autocrossing when autonegotiation is switched on 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode State on delivery autonegotiation is activated with exception of the HIPER Ring ports 100 Mbit s full duplex no autocrossing The socket housings are electrically connected to the chassis Pin Function 3 4 1 TD Transmit Data 2 RD Receive Data 3 TD Transmit Data 2 1 4 RD Receive Data Housing shield Fig 7 Pin assignment of a TP T
2. mum 9 6 to 60 V DC 46 to 58 V DC non changeable fuse 800 V DC The isolating voltage is limited to 90 VDC 1 mA by protective com ponents 707 V DC 2 250 V DC 1 A max 60 V DC max or 30 V AC max Surrounding air 40 C to 85 C 40 F to 185 F 0 to 95 non condensing up to 2 000 m 795 hPa higher altitudes on demand Surrounding air 40 C to 70 C 40 F to 158 F IP 67 OCTOPUS 8M 16M 24M Release 07 2008 EMV and stability EMV interference proof EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 9 EMV emitted immunity EN 55022 Discharge of static electricity Contact discharge Air discharge Electromagnetic fields Test level 3 80 2000 MHz Fast transients burst Power line Data line Surge voltage Power line line line Power line line earth Data line Cable based RF faults 150 kHz 80 MHz Impulse shaped magnetic fields OCTOPUS Train only Class A FCC 47 CFR Part 15 Class A Germanischer Lloyd Stability Vibration Shock Network size Rules f Classification and Construction VI 7 3 Part 1 IEC 60068 2 6 Test FC testing level in line with IEC 61131 2 Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1 6 kV 8 KV 20 V m 4 kV 4 kV 1 kV 2 kV 1 kV 10 V 300 A m Yes Yes Yes Yes Yes IEC 870 2 2 Table 3 Normal Installation in line with EN 61850 3 Ye
3. 002 whole specified temperature range of the OCTOPUS This might Note Some recommended accessory parts do not support the limit the possible operating conditions for the entire system Spe cially designed connector types with protection class IP67 and ex tended temperature range are available on request Unsealed accessories like RJ45 adapters or terminal access cables are not suitable inside IP67 areas Name Pocket Guide AutoConfiguration Adapter ACA21 M12 Terminal access cable Cable socket ELWIKA 5012 PG7 5 pole M12 socket for voltage suppyl and signal contact 5 pole M12 socket A coded with two cable junctions suitable for field mounting M12 connector D coded Connecting cable with M12 connector D coded Transition M12 D coded to RJ45 Netzmanagement Software Industrial HiVision Netzwork management software HiVision OPC server software HiOPC OCTOPUS 8M 16M 24M Release 07 2008 Order no 280 720 851 943 913 001 943 902 001 933 175 100 RKC5 Duo 934 445 001 934 497 00x 934 498 001 943 156 xxx 943 471 100 943 055 001 29 Based specifications and standards EN 61000 6 2 2005 Generic standards Immunity for industrial environments EN 55022 2006 Information technology equipment Radio disturbance characteristics EN 61131 2 2003 Programmable Controllers FCC 47 CFR Part 15 2006 Code of Federal Regulations Germanischer Lloyd Rules for Classification Construction VI 7 3 Par
4. per second port is switched to stand by flashes green 3 times per second port is disabled flashes yellow data reception at the specific port Hinweis The port status for activated Power over Ethernet can be requested via the software management 2 3 Carrying out basic settings IP addresses must be entered when the device is installed for the first time The device provides 6 options for configuring the IP addresses Entry via the V 24 connection Entry by HiDiscovery protocol Configuration via BOOTP Configuration via DHCP Configuration via DHCP Option 82 The AutoConfiguration Adapter State of delivery IP address The device looks for the IP address using DHCP Password for management user password public read only admin password private read and write V 24 data rate 9 600 baud Ring redundancy on Ring ports on 100 Mbit s full duplex Optical 100 Mbit s ports 100 Mbit s full duplex All other ports autonegotiation Ethernet ports Link status is not evaluated signal contact Redundancy manager switched off OCTOPUS 8M 16M 24M Release 07 2008 23 USB interface ACA21 M12 The USB socket offers an interface for the local connection of an Auto Configuration Adapter ACA21 M12 It is a device for saving loading the configuration and the diagnosis information and for loading the software The USB interface is a shielded 5 pin M12 socket with A coding ACA21 M12 pin assignment Pin Function 3 4 i 5 amp 3 D D
5. 039679002020708000 h HIRSCHMANN A Belden Company User Manual Installation IP67 Switch OCTOPUS 8M OCTOPUS 16M OCTOPUS 24M L an PE lo gi 0 0 0 q D D d D e m LA B Te g GE wet ik 5 en e OCTOPUS 8M OCTOPUS 16M OCTOPUS 16M 2FX OCTOPUS 8M Train OCTOPUS 16M Train OCTOPUS 16M 8PoE 2FX OCTOPUS 8M 8PoE OCTOPUS 16M 8PoE OCTOPUS 8M 6PoE qi p e e elf gal II e elg qe D D A le mx as U U J CE U OCTOPUS 24M OCTOPUS 24M 2FX OCTOPUS 24M Train OCTOPUS 8M 16M 24M Technical support Release 07 2008 HAC Support hirschmann de The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone 2008 Hirschmann Automation
6. 32 4 Btu IT h 32 4 Btu IT h 45 9 Btu IT h 493 5 Btu IT h 44 4 Btu IT h 57 9 Btu IT h 510 5 Btu IT h 46 0 Btu IT h 46 0 Btu IT h 50 9 Btu IT h Note The included cable socket ELWIKA 5012 PG7 933 175 100 supports a temperature range from 25 C to 70 C This might limit the possible operating conditions for the entire system Specially designed connector types with protection class IP67 and extended temperature range are available on request Device OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8PoE OCTOPUS 16M 2FX OCTOPUS 16M 8P0E 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX 28 Scope of delivery OCTOPUS device Cable socket ELWIKA 5012 PG7 for supply voltage and indicator contact 9 on theOCTOPUS 8M model 17 on the OCTOPUS 16M model or 25 on the OCTOPUS 24M model pro tective caps to protect unused ports User Manual Installation and CD ROM OCTOPUS 8M 16M 24M Release 07 2008 Order numbers product name Device OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8P0E OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX Accessories Order numbers 943 931 001 943 983 001 943 967 001 943 967 101 943 912 001 943 984 001 943 960 001 943 912 002 943 960 101 943 923 001 943 985 001 943 923
7. X interface M12 socket l Connect the data lines according to your requirements Use a shielded CAT5 cable Use a shielded 4 pin M12 connector 1 Connect the cable shield to the connector housing OCTOPUS 8M 16M 24M Release 07 2008 19 M12 MDI TX 1 RX 2 TX 3 RX 4 Shield S M12 MDI TX 1 RX 2 De 3 RX 4 Shield S M12 MDI TX 1 RX 2 TX 3 RX 4 Shield S M12 MDI TX 1 RX 2 TX 3 RX 4 Shield S Fig 8 LECU M12 4 to M12 4 crossover cable M12 4 to M12 4 straight through cable M12 4 to RJ45 crossover cable M12 4 to RJ45 straight through cable M12 MDI 1 TX 2 RX 3 TX 4 RX S Shield M12 MDI X via autocrossing port 1 RX 2 TX 3 RX 4 TX S Shield RJ45 MDI end device 1 TX 2 TX 3 RX 6 RX S Shield RJ45 MDI X switch RX RX TX TX Own n Shield Patch cables for operating the OCTOPUS 10 100 Mbit s twisted pair connection OCTOPUS PoE 10 100 Mbit s ports RJ45 sockets allow the connection of terminal devices or independent network segments according to the IEEE 802 3 100BASE TX 10BASE T and IEEE 802 3af Power over ETHERNET on data lines standards These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s f
8. alt 0 lilo q D ED be U JS G U U OCTOPUS 16M 8PoE OCTOPUS 16M 8P0E 2FX Fig 1 PoE compliant ports on the OCTOPUS PoE devices OCTOPUS 8M 16M 24M Release 07 2008 11 2 Assembly and startup procedure The device has been developed for practical application in a harsh industrial environment Accordingly the installation process has been kept simple On delivery the device is ready for operation The following procedure is appropriate for assembly Unpacking and checking Connecting the connector for supply voltage and signal contact Fitting the device grounding Fitting the connector for the power supply startup procedure Connecting the data lines 2 1 Device installation 2 1 1 Unpacking and checking Check whether the package was delivered complete see Scope of delivery on page 28 Check the individual parts for transport damage 2 1 2 Connecting the connector for supply voltage and signal contact The supply voltage and the signal contacts are connected via a 5 pole M12 circular connector A coding e g ELWIKA 5012 PG7 from Hirschmann included in scope of delivery 24V supply voltage The supply voltage can be connected redundantly Both inputs are uncoupled With redundant supply the transformer supplies the device alone with the higher output voltage The supply voltage is electrically isolated from the housing Note With non redundant supply of the mains voltage the device reports a pow
9. ance with IEC EN 60950 1 The supply voltage is electrically isolated from the housing 1 Use only undamaged parts 1 Relevant for North America The subject unit is to be suppplied by a Class 2 power source comp lying with the requirements of the National Electrical Code table 11 b If power is redundant supplied two individual power sources the po wer sources together should comply with the requirements of the Na tional Electrical Code table 11 b 1 Relevant for North America Use 75 C copper CU wire Class 1 only Relevant for North America for devices certified for hazardous locations Power input and output I O wiring must be in accordance with Class Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having jurisdiction Shielding ground The shielding ground of the connectable twisted pairs lines is connected to the chassis as a conductor LI Beware of possible short circuits when connecting a cable section with conductive shielding braiding OCTOPUS 8M 16M 24M 4 Release 07 2008 Housing Only technicians authorized by Hirschmann are permitted to open the housing The device is grounded via the separated ground screw It is located on the left under the front panel CT Make sure that the electrical installation meets local or nationally ap plicable safety regulations Environment The device may only be operated in t
10. and Control GmbH Manuals and software are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use For devices with embedded software the end user license agreement on the en closed CD applies The performance features described here are binding only if they have been expressly guaranteed in the contract This publication has been created by Hirschmann Automation and Control GmbH according to the best of our knowledge Hirschmann reserves the right to change the contents of this manual without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the details in this publication Hirschmann can accept no responsibility for damages resulting from the use of the network components or the associated operating software In addition we refer to the conditions of use specified in the license contract Printed in Germany 28 7 08 Hirschmann Automation and Control GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Tel 49 1805 141538 039 679 002 02 0708 2 2 2 3 Content Safety instructions About this manual Legend Device description Description of the device models 1 1 1 Devices without Power over Ethernet 1 1 2 Devices with Power over Ethernet Assembly and startup proc
11. ata 1___4 GND Ground OV 5 D Data Fig 11 Pin assignment of the ACA21 12M M12 socket Note The ACA11 M12 AutoConfiguration Adapter available as an accessory for certain Hirschmann devices is not designed for applications with OCTOPUS devices If you wish to apply an AutoConfiguration Adapter to your OCTOPUS device use the ACA21 M12 USB socket of the OCTOPUS device see Fig 11 V 24 interface external management A serial interface is provided on the V 24 interface for the local connec tion of an external management station VT 100 terminal or PC with appropriate terminal emulation This makes it possible to establish a connection to the Command Line Interface CLI and to the system monitor VT 100 terminal settings Speed 9 600 baud Data 8 bit Stopbit 1 bit Handshake off Parity none The socket housing is electrically connected to the device The V 24 interface is electrically connected to the supply voltage OCTOPUS 8M 16M 24M 24 Release 07 2008 Pin assignment of the V 24 interface Terminal cable Pin Function M12 DB9 3 4 1 TX Transmit Data 3 4 Og Pin 5 GE 2 RX Receive Data CE 2o Pin 8 O 3 3 N C Not connected Oo ping 2 3 5 Fig 12 Pin assignment of the V24 interface M12 socket Note You will find the order number for the terminal cable which is ordered separately in the chapter Technical data on page 26 Note The ACA11 M12 AutoConfiguration Adapter available as an acce
12. e addresses of our contract partners on the Internet http www hirschmann ac com Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on the Hirschmann internet site www hirschmann ac com faq Hirschmann Competence Center In the longterm product excellence alone is not an absolute guarantee of a successful project implementation Comprehensive service makes a difference worldwide In the current scenario of global competition the Hirschmann Competence Center stands head and shoulders above the competition with its comprehensive spectrum of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the technological fundamentals product briefing and user training with certification Support ranges from commissioning through the standby service to maintenance concepts With the Competence Center you firmly rule out any compromise the client specific package leaves you free to choose the service compon ents that you will use Internet http www hicomcenter com OCTOPUS 8M 16M 24M Release 07 2008 31 h HIRSCHMANN A Belden Company
13. ebcams sensors printer servers and WLAN access points via 10BASE T 100BASE TX for example With PoE these OCTOPUS 8M 16M 24M 10 Release 07 2008 terminal devices are powered by the twisted pair cable The OCTOPUS PoE has depending on the device model six to eight 10BASE T 100BASE TX ports M12 sockets for connecting network seg ments or PoE terminal devices PD Powered Device on all IEEE802 3af power classes up to max 15 4 W power output Gerat Number of FX ports Number of TX ports compliant TX ports OCTOPUS 8M 8PoE 8 8 Port 1 to 8 OCTOPUS 8M 6PoE 8 6 Port 1 to 3 and 5 to 7 OCTOPUS 16M 8PoE 16 8 Port 1 to 8 OCTOPUS 16M 8P0E 2FX 2 16 8 Port 1 to 8 The current is supplied on the data signal line pairs the individual ports are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative A RE Power over ETHERNET Port without PoE Port with PoE AS 0 es
14. edure Device installation 2 1 1 Unpacking and checking 2 1 2 Connecting the connector for supply voltage and signal contact 2 1 3 Fitting the device grounding 2 1 4 Connecting the power supply startup procedure 2 1 5 Connecting the data lines Displays Carrying out basic settings Technical data General data EMV and stability Network size Power consumption power output Scope of delivery Order numbers product name Accessories Based specifications and standards Certifications Further support OCTOPUS 8M 16M 24M Release 07 2008 10 10 10 26 26 27 27 28 28 29 29 30 31 Safety instructions This manual contains instructions which must be observed to ensure your own personal safety and to avoid damage to devices and machinery Certified usage Please observe the following The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or approved by Hirschmann The product can only be operated correctly and safely if it is transported stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Supply voltage The devices are designed for operation with a safety extra low voltage Thus they may only be connected to the supply voltage connec tions and to the signal contact with SELV circuits with the voltage restric tions in accord
15. er failure You can prevent this message by applying the supply voltage over the two inputs or by changing the configuration via manage ment OCTOPUS 8M 16M 24M 12 Release 07 2008 Pin assignment of the device connector Pin Function EJ 1 24V DC 2 5 3 OV gt Fig 2 Connection of the 24V supply voltage and signal contact PoE supply voltage optionally The PoE supply voltage for OCTOPUS PoE devices is connected via a 5 pin M12 connector A coding e g ELWIKA 5012 PG7 from Hirschmann included in the scope of delivery The OCTOPUS PoE devices 48 V DC safety low voltage are supplied with PoE power by an external power supply unit The PoE voltage is fed into the 5 pin M12 connector of the OCTOPUS PoE The twisted pair cables at ports 1 to 8 or 1 to 6 on OCTOPUS 8M 6PoE are supplied with PoE volta ge via the pins 1 amp 4 on the data signal line pairs phantom supply L Make sure that the external power supply unit you use to provide the PoE voltage fulfils the following basic prerequisites Insulation requirements according to IEEE 802 3af insulation resistance 48 V output to rest of the world 2 250 V DC for 1 min Output power lt 150 W Current limitation lt 5 A Power supply unit and PoE media module form a limited power source according to IEC60950 1 The external PoE power supply unit must be able to provide the power for the connected PDs 10 ms failure bridging incl
16. he listed maximum surrounding air temperature range at the listed relative air humidity range non conden sing L The installation location is to be selected so as to ensure compliance with the climatic limits listed in the Technical Data Make sure that there is no heat conduction from the surroundings to the device It is possible to mount the device on a temperature insula ting material CT To be used in a Pollution Degree listed in the Technical Data Accessories Warning A HOT SURFACE RISK OF BURNS Please note that some characteristics of the recommended accessory parts may differ from the appropriate product This might limit the possible operating conditions for the entire system Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and ope ration of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering trained in providing first aid OCTOPUS 8M 16M 24M Release 07 2008 5 General Safety Instructions This device is electrical
17. ly operated Adhere strictly to the safety require ments relating to voltages applied to the device as described in the ope rating instructions Failure to observe the information given in the warnings could result in serious injury and or major damage CT Only personnel that have received appropriate training should operate this device or work in its immediate vicinity The personnel must be ful ly familiar with all of the warnings and maintenance measures in these operating instructions CT Correct transport storage and assembly as well as careful operation and maintenance are essential in ensuring safe and reliable operation of this device Only use undamaged parts These products are only to be used in the manner indicated in this ver sion of the manual L Any work that may have to be performed on the electrical installation should be performed by fully qualified technicians only LIU Warning OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M 2FX LED or LASER components according to IEC 60825 1 2001 CLASS 1 LASER PRODUCT LIGHT EMITTING DIODE CLASS 1 LED PRODUCT National and international safety regulations Make sure that the electrical installation meets local or nationally ap plicable safety regulations Note on the CE marking The devices comply with the regulations contained in the following Euro pean directives 2004 108 EG Directive of the European Parliament and of the Council on the appr
18. oxi mation of the laws of the member states relating to electromagnetic compatibility 72 245 EEC 2006 28 EG Radio interference electromagnetic compatibility in vehicles Certified devices are marked with an e1 type approval number In accordance with the above named EU directives the EU conformity declaration will be at the disposal of the relevant authorities at the follo wing address OCTOPUS 8M 16M 24M Release 07 2008 Hirschmann Automation and Control GmbH Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Germany Phone 49 7127 14 1480 The product can be used in living areas living area place of business small business and in industrial areas Interference immunity EN 61000 6 2 2005 Emitted interference EN 55022 2006 Class A Warning This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC value limits FCC note Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations These requirements are designed to provide sufficient protection against interference where the device is being used in a business environment The device creates and uses high frequencies and can radiate same and if it is not installed and
19. powered devices in line with EN 61131 2 CE marking in line with 2004 108 EG Certification for railway applications electronic equipment used on rolling stock in line with EN 50155 CT Connect the PoE voltage to the 5 pin M12 connector included in the scope of delivery as shown in the following diagram Make sure that the following requirements are met Supply line length lt 3 m Supply line cross section is suitable for 3 3 A OCTOPUS 8M 16M 24M Release 07 2008 13 Note Do not operate the OCTOPUS PoE devices in line Only connect external power supply units each to one OCTOPUS PoE device directly Pin assignment of the M12 connector Pin Function Fig 3 Connection of the PoE supply voltage and the signal contact Signal contact The signal contact FAULT pin assignment of the connector Connection of the 24V supply voltage and signal contact on page 13 or Connection of the PoE supply voltage and the signal contact on page 14 monitors proper functioning of the device thus enabling remote diagnostics You can specify the type of function monitoring in the Management You can also use the Management to switch the signal contact manually and thus control external devices A break in contact is reported via the potential free signal contact relay contact closed circuit The failure of at least one of the two supply voltages A continuous malfunction in the device internal voltage supply The defec
20. s EN 61373 category 1 class A broadband noise installation in line with EN 50155 IEC 60068 2 27 Test Ea test level in line with IEC 61131 2 Yes Yes IEC 870 2 2 Table 3 Normal Installation in line with EN 61850 3 Yes EN 61373 category 1 class A broadband noise installation in line with EN 50155 Length of a twisted pair segment 100 m approx cat5e cable with 100BASE TX Table 1 TP port 10BASE T 100BASE TX Connec tor Wave length Fiber System Expansion Fiber data attenuation Yes MicroFX MM 1300nm 50 125 um 0 8 dB 0 5 km 1 0 dB km 800 MHz km MircoFX MM 1300 nm 62 5 125 um 0 11 dB 0 4 km 1 0 dB km 500 MHz km Table 2 F O port 100BASE FX OCTOPUS 8M 16M 24M Release 07 2008 27 Power consumption power output Name OCTOPUS 8M OCTOPUS8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16MTrain OCTOPUS 16M 8PoE OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX Scope of delivery A no PD powered device 8 x Class0 PD no PD powered device 6 x Class0 PD no PD powered device 8 x Class0 PD no PD powered device 8 x Class0 PD Maximum power consumption 6 2 W 6 2 W 10 0 W 142 0 W 10 0 W 110 0 W 9 5 W 9 5 W 13 5 W 145 0 W 13 0 W 17 0 W 150 0 W 13 5 W 13 5 W 14 9 W Power output 21 1 Btu IT h 21 1 Btu IT h 34 0 Btu IT h 483 3 Btu IT h 34 0 Btu IT h 374 4 Btu IT h
21. s IP67 is only achieved when bolted together The other components beeing attached to the system have to fulfil the IP67 protection class in order to make the whole system IP 67 suitable 1 Empty slots must be sealed with the protective caps supplied 1 Make sure that you only attach connectors and other components which fulfil the IP67 protection type and which are suitable for the temperature range of 40 C to 70 C OCTOPUS 8M 16M 24M Release 07 2008 15 183 8 Ds O amp amp 150 169 188 5 Fig 4 Dimensions OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 8M 16M 24M 16 Release 07 2008 D D D D D D D ol Oli t i 120 150 169 188 5 Fig 5 Dimensions OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX OCTOPUS 16M 8PoE OCTOPUS 16M 8PoE 2FX OCTOPUS 8M 16M 24M Release 07 2008 17 D D D D D 338 2 326 4 D D D 188 5 Fig 6 Dimensions OCTOPUS 24M OCTOPUS 24M Train
22. ssory for certain Hirschmann devices is not designed for applicati ons with OCTOPUS devices If you wish to apply an AutoConfiguration Adapter to your OCTOPUS de vice use the ACA21 M12 USB socket of the OCTOPUS device see Fig 11 You will find a detailed description of the configuration in the Basic Configuration User Manual on the CD ROM OCTOPUS 8M 16M 24M Release 07 2008 25 3 Technical data General data Dimensions WxHxD Weight Voltage supply Overload current protection at input Isolating voltage between operating voltage connec tors and housing Signal contact Surrounding Operating temperature Protection types 26 OCTOPUS 8M OCTOPUS 16M OCTOPUS 24M OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8PoE OCTOPUS 16M 2FX OCTOPUS 16M 8P0E 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX Operating voltage OCTOPUS without PoE OCTOPUS PoE OCTOPUS without PoE or Train OCTOPUS Train OCTOPUS PoE Storage temperature Humidity Atmospheric pressure OCTOPUS Protection type 189 mm x 184 mm x 70 mm 189 mm x 261 mm x 70 mm 189 mm x 338 mm x 70 mm 1310 g 1310 g 1310 g 1310 g 1920 g 1920 g 1920 g 1950 g 1950 g 2540 g 2540 g 2570 g safety extra low voltage SELV PELV redundant inputs decou pled Relevant for North America Nec Class 2 power source 5 A maxi
23. t 1 cUL 508 1998 Safety for Industrial Control Equipment RL 72 245 EEC 2006 28 EG e1 type approval for application in vehicles EN 50155 Railway applications Electronic equipment used on rolling stock EN 50121 4 2000 Railway applications EMC emitted interference and interfe rence immunity for signal and telecommunication systems Table 3 List of based specifications and standards Certified devices are marked with a certification identifier IEEE 802 1 D Switching GARP GMRP Spanning Tree IEEE 802 1 D 1998 Media access control MAC bridges includes IEEE 802 1p Priority and Dynamic Multicast Filtering GARP GMRP IEEE 802 1 Q Tagging IEEE 802 1 Q 1998 Virtual Bridged Local Area Networks VLAN Tagging GVRP IEEE 802 1 w 2001 Rapid Reconfiguration IEEE 802 3 2002 Ethernet Table 4 List of IEEE standards Certifications Standard without PoE Sen OCTOPUS Train cUL 508 CSA C22 2 No 142 yes pending no German Lloyd yes pending no el type approval yes no no FCC 47 CFR Part 15 2006 yes yes yes EN 50155 no pending yes EN 50121 4 2000 no no yes EN 61131 2 2003 yes yes yes Table 5 Certifications actual state see www hirschmann com OCTOPUS 8M 16M 24M 30 Release 07 2008 4 Further support Technical questions and training courses In the event of technical queries please talk to the Hirschmann contract partner responsible for looking after your account or directly to the Hirschmann office You can find th
24. tion Real Time Clock OCTOPUS 8M 16M 24M Release 07 2008 9 Communication on every level The addition to the OCTOPUS 8M 16M 24M range of the RS20 RS30 Open Rail range the MICE range of switches the MACH range of backbone switches the BAT wireless transmission system the EAGLE security system and products for the LION control room provides continuous communication across all levels of the company 1 1 Description of the device models 1 1 1 Devices without Power over Ethernet The device models OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX have depending on the model 8 to 24 10BASE T 100BASE TX ports RJ45 connectors for connecting network segments or terminal devices OCTOPUS 8M Train OCTOPUS 16M Train and OCTOPUS 24M Train are devices with a certification for railway applications electronic equipment used on rolling stock in line with EN 50155 Device Number of FX ports Number of TX ports OCTOPUS 8M OCTOPUS 8M Train 8 OCTOPUS 16M OCTOPUS 16M Train 16 OCTOPUS 16M 2FX 2 16 OCTOPUS 24M OCTOPUS 24M Train 24 OCTOPUS 24M 2FX 2 24 1 1 2 Devices with Power over Ethernet The device models OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M 8PoE OCTOPUS 16M 8P0E 2FX in short OCTOPUS PoE support Power over ETHERNET PoE accor ding to IEEE 802 3af They allow the connection and remote supply of IP telephones Voice over IP w
25. tive link status of at least one port With the device the indi cation of link status can be masked by the management for each port Link status is not monitored in the delivery condition The loss of Redundancy guarantee Error during self test Incorrect configuration of the HIPER Ring or ring coupling The following condition is reported in RM mode additionally Ring redundancy guaranteed Ring redundancy is not monitored in the delivery condition LJ Connect the power supply and signal lines OCTOPUS 8M 16M 24M 14 Release 07 2008 2 1 3 Fitting the device grounding To protect the exposed contacts of the components still to be installed from dirt the individual system components must be connected in a dry and clean area Ports which are not assigned are to be closed with the covering caps contained in the scope of delivery Note Connectors are not electrical isolating devices Therefore first plug the connector to the power supply plug and then switch on the power supply L The installation location is to be selected so as to ensure compliance with the climatic limits listed in the Technical Data Make sure that there is no heat conduction from the surroundings to the device It is possible to mount the device on a temperature insulating material 1 Prepare assembly at the installation site drill holes at the installation site Mechanical assembly at the installation site with M5 screws Note The protection clas
26. ts and initializes itself The device then performs a selftest The process lasts approximately 60 se conds el A HIRSCHMANN ai OCTOPUS 24M 2FX Port status LEDS 8 Oe here for port 1 to 4 0000 P1 P2 RM FAULT yv Device status LEDs Device status These LEDs provide information about conditions which affect the opera tion of the whole device P1 Power green yellow LED Meaning lit green the supply voltage P1 is on not lit supply voltage is too low P2 Power green yellow LED Meaning lit green the supply voltage P2 is on not lit supply voltage is too low FAULT Error Meaning lit red the signal contact is open i e it reports an error not lit the signal contact is closed i e it does not report an error le LED a Manager green Meaning lit green RM function active redundant port not active lit yellow RM function active redundant port active not lit RM function not active flashes green Incorrect configuration of HIPER Ring e g ring not connected to ring port D If the manual adjustment is active on the signal contact then the error display is independent of the signal contact setting OCTOPUS 8M 16M 24M 22 Release 07 2008 Port status A green yellow LEDs on the specific ports display port related informa tion LS DA Link status Data green yellow LED Een not lit no data reception at the specific port no connection lit green valid connection flashes green 1 time
27. ull duplex mode Power over ETHERNET PoE 20 OCTOPUS 8M 16M 24M Release 07 2008 Delivery condition Autonegotiation activated except for the ring ports 100 Mbit s full duplex The socket housing is electrically connected to the front panel The PoE voltage is fed in via the pins 1 amp 4 onto the data signal line pairs phantom supply Pole Wire color Function PoE PSE 3 4 1 White orange TX Transmit Data 2 White green RX Receive Data 3 Orange TX Transmit Data 2 1 4 Green RX Receive Data 7 Housing shield Fig 9 Pin assignment of the TP TX interface for PoE for supply via the data signal line pairs M12 socket Connect the data lines according to your requirements Use shielded CAT5 cable Use a shielded 4 pin M12 connector 1 Apply the shield of the cable onto the housing of the connector Patch cables for operating the OCTOPUS are illustrated in the figure above see Fig 8 100 Mbit s F O connection MicroFX 100 MBit s F O ports enable the connection of terminal devices or inde pendent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support full duplex mode Pin Function 3 4 TIN C Not connected 2 RX Receive Data 3 N C Not connected 1 4 gt TX Transmit Data Fig 10 Pin assignment of a MicroFX socket OCTOPUS 8M 16M 24M Release 07 2008 21 2 2 Displays After applying the operating voltage the software star
28. used in accordance with this operating manual it can cause radio transmission interference The use of this device in a living area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state country OCTOPUS 8M 16M 24M Release 07 2008 7 About this manual The following manuals are included as PDF files on the enclosed CD ROM User manual Installation User manual Basic configuration User manual Redundancy configuration Reference manual Web based Interface and Reference manual Command Line Interface If you use Network Management Software HiVision you have further opportunities to have an event logbook configure the System Location and System Name configure the network address range and SNMP parameters save the configuration on the Switch simultaneous configuration of several Switches configure the relevant ports to be displayed red if there is no link state Legend The commendations used in this manual have the following meanings Listing 11 Work step Subheading OCTOPUS 8M 16M 24M 8 Release 07 2008 1 Device description The OCTOPUS 8M 16M 24M devices are designed for the special requirements of industrial automation They meet the relevant industr
29. y standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The devices operate without fans and have a redundant voltage supply The HIPER Ring redundancy concept enables you to quickly carry out a reconfiguration and also a simple configuration with only one additional connection It can be easily managed via a Web browser via Telnet with a management software product such as Viion or locally on the switch V 24 interface The OCTOPUS 8M 16M 24M allows you to construct switched industrial ETHERNET networks that conform to the IEEE 802 3 and 802 3u standards using copper wires or optical fibers in a bus or ring topology You can connect terminal devices and other infrastructure components via twisted pair cables and multi mode optical fibers The twisted pair ports support autocrossing autonegotiation and autopolarity Scope of functions Depending on the software you choose the devices provide you with a large range of functions Redundancy functions Rapid Spanning Tree Redundant Ring Structure HIPER Ring Redundant Coupling Link Aggregation Redundant Power Supply Protection from unauthorized access Synchronized system time in the network Network load control Function diagnosis Diagnostics hardware self testing Reset Priority VLAN Topology recognition Web based interface Command Line Interface CLI SNMP 802 1x port authentica
Download Pdf Manuals
Related Search
Related Contents
MINICUBE OCD Checker MINICUBE Utility UM ModelSim SE Installation and Licensing Guide User GUide • GUÍa del UsUario proteinScape 3.0 User Manual NEU - Fisher Scientific 取扱説明書 - CASIO User Manual for EL5 Servo - American Motion Technology LLC Maytag W10240583B-SP User's Manual sistema di sicurezza con 3 settori e manuale di installazione e di Copyright © All rights reserved.