Home
Genesys 3U Datasheet
Contents
1. Genesys Programmable DC Power Supplies 10kW 15kW in 3U Built in RS 232 amp RS 485 Interface Advanced Parallel Operation Optional Interfaces LXI Compliant LAN GPIB IEEE 488 2 amp SCPI Compliant Isolated Analog Program Monitor j i yt The Genesys family of programmable power supplies sets a new standard for flexible reliable AC DC power systems in OEM Industrial and Laboratory applications Features include High Power Density 10kW 15kW in 3U package High Output Current up to 1000ADC Wide Range of popular worldwide 3 AC inputs 208VAC 400VAC 480VAC Power Factor 0 88 Passive PFC on all AC Inputs Output Voltage up to 1500V Output Current up to 1000A Built in RS 232 RS 485 Interface Standard Last Setting Memory Front Panel Lockout Advanced Parallel configuration reports total system current up to four identical units Global Commands for Serial RS 232 RS 485 Interface Continuous Encoders for Voltage and Current Adjustment Independent Remote ON OFF and Remote ENABLE DISABLE Reliable Modular and SMT Design 19 Rack Mounted for ATE and OEM Applications zero stack Optional Interfaces LXI Compliant LAN Class C GPIB IEEE 488 2 amp SCPI Compliant w Multi Drop capability Isolated Analog Programming and Monitoring Interface 0 5V 0 10V amp 4 20mA e LabView and LabWindows Software Drivers Worldwide Safety Agency Approvals UL Recognized an
2. 7 OVP Trip Point Vv 1 4 REMOTE ANALOG CONTROLS amp SIGNALS 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of Vo rated 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of lo rated 0 100 0 5 10kohm full scale user selectable Accuracy amp Linearity 1 of Vo rated 0 100 0 5 10kohm full scale user selectable Accuracy amp Linearity 1 of lo rated By Voltage 0 6V Disable 2 15V Enable default or Dry Contact Open ENA Short DIS user selectable logic 0 5V or 0 10V Accuracy 1 of lo rated user selectable 0 5V or 0 10V Accuracy 1 of Vo rated user selectable Yes TTL high OK OV Fail 500ohm series impedance CV TTL High 4 5V Max source current 10mA CC TTL Low 0 0 4V Max sink current 10mA Dry contact Open Off Short On Max voltage across Enable Disable contacts 6V Selects Remote or Local operation by voltage 0 0 6V Local 2 15V Remote Signals operating mode Open collector Local Open Max voltage 30V Remote On Max sink current 10mA 1 5 FRONT PANEL 1 Control Functions Vout lout manual adjust by separate encoders coarse and fine adjustment selectable OVP UVL manual adjust by Voltage Adjust encoder Front Panel Lock Unlock Address selection by Voltage Adjust encoder of addresses 31 AC ON OFF Output On Off Restart Modes Auto Safe Foldback Control CV to CC Go to Local RS 232
3. 120 65 8 63 0 SS L 12 50 J 317 50 NOTE 3 L 16 38 415 93 NOTES 1 Threaded stud terminals for 800V 1500V Output M5 x 1 2 Input Terminals M6 x 1 3 Ground M5 x 1 2 3 Mounting for Slide Mounts not included Recommend General Devices Chassis Trak P N C230 S 122 Secure with pan head screw M5 x 0 8 8mm long max 11 Genesys 3U 10 15kW 50 80 OO S00 mono mono DOoomoooO im TH Oy 000m0 60000 DODDUD GOOD DDDEDD p000 OOO 000mm Ww OU0O000 Power Supply Identification Accessories Genesys 3U 10 15kW How to Order GEN 10 1000 LAN 3P208 Factory Options AC Input Options Series Output Output Option 3P208 Three Phase 208VAC Name Voltage Current LAN 3P400 Three Phase 400VAC 0 10V 0 1000A IEMD 3P480 Three Phase 480VAC Output Output Output Output Output Output Voltage Current Power Voltage Current Power Vdc Adc kW Vdc GEN 75 1000 GEN 200 50 GEN 101000 oo omo 10 GEN20500 0 20 oso w 0 33 o GEN 40 250 0 200 io 7 os 0 GEN 100100 oo ee nl cool GEN 125 120 ose 10 Factory
4. Go to Local RS 232 RS 485 IEEE IEMD and LAN selection by rear panel DIP switch Baud rate selection RS 232 RS 485 only 1200 2400 4800 9600 and 19 200 by current adjust encoder Advanced Parallel Master Slave Hx Master unit where x of Slave units 0 to 4 S Slave unit s 2 Display Voltage 4 digits Accuracy 0 5 of Vo rated 1 count Current 4 digits Accuracy 0 5 of Vo rated 1 count Voltmeter displays voltage at power supply Local sense or at load Remote sense 3 Indications Green LED s PREVIEW FOLD REM LOCAL OUT ON OFF CV CC FINE Red LED ALRM OVP OTP FOLD AC FAIL ENA SO W V V V V V ms ms ms A A A m mMm m 1 6 DIGITAL PROGRAMMING amp READBACK 1 Vout Programming Accuracy 0 5 of rated Output voltage 2 lout Programming Accuracy 0 5 of rated Output current for units with lo lt 187 5A 0 7 of rated Output current for lo gt 187 5A 3 Vout Programming Resolution 0 02 of Vo rated 4 lout Programming Resolution 0 04 of lo rated 5 Vout Readback Accuracy 0 1 of Vo actual 0 2 of Vo rated 6 lout Readback Accuracy 0 1 of lo actual 0 4 of lo rated 7 Vout Readback Resolution 0 02 of Vo rated 8 lout Readback Resolution 0 02 of lo rated 9 OV Response Time OmS maximum between Vout exceeding IEEE Limit and supply Inhibit turning On 10 Other Functions Set OVP UVL limits Set Local Remote Operating parameters and Status Get
5. Standard Serial Interface allows daisy chain control of up to 31 power supplies on the same communication bus with built in RS 232 amp RS 485 Interface Programming Options Factory installed IEEE Multi Drop Interface P N IEMD Allows IEEE Master to control up to 30 Standard slaves over RS 485 daisy chain Only the Master needs be equipped with IEEE Interface IEEE 488 2 amp SCPI Compliant Program Voltage Program Current Measure Voltage Measure Current Over Voltage setting and shutdown Current Foldback shutdown e Error and Status Messages Multi Drop Slave Option is Standard P N e Standard Units are equipped with the Multi Drop Slave RS 485 function Allows RS 485 Master to control up to 30 standard Slaves over RS 485 Daisy chain Isolated Analog Programming e Four Channels total Two to Program Voltage and Current Two to Monitor Voltage and Current Isolation allows operation with floating references in harsh electrical environments Choose between programming with Voltage or Current Connection via removable terminal block Phoenix MC1 5 8 ST 3 81 Voltage Programming User selectable 0 5V or 0 10V signal P N 1S510 Power supply Voltage and Current Programming Accuracy 1 Power supply Voltage and Current Monitoring Accuracy 1 5 e Current Programming with 4 20mA signal P N 1S420 Power supply Voltage and Current Programming Accuracy 1 LAN Interface LXI Compliant to C
6. 70 C 3 Operating Humidity 20 80 RH non condensing 4 Storage Humidity 10 90 RH non condensing 5 Vibration amp Shock ASTM D4169 Standard Practice for Performance Testing of Shipping Containers and Systems Shipping Unit Single Package Assurance Level Level Il Acceptance Criteria Criterion 1 No product damage Criterion 2 Packaging is intact Distribution Cycle 12 Air intercity and motor freight local unitized is used 6 Altitude Operating 50 C up to 7500 ft 2500m 45 C from 7501 to 10 000ft 2501m 3000m Non Operating 40 000 ft 12 000m 7 Audible Noise 65dBA at lo rated measured 1m from front panel 2 4 EMC 4 1 208VAC Input CE Mark 1 ESD EN61000 4 2 IEC 801 2 Air discharge 8kV Contact discharge 4kV 2 Fast Transients 3 Surge Immunity 4 Conducted Immaniy 5 Radlated Immunity 6 Power Frequency Magnetic Fid 7 Conducted Emissions 8 Raciated Emissions 2 A00VAG SB0VAG 4 put 1 ESD EN61000 4 2 IEC 801 2 Air discharge 8kV Contact discharge 4kV 2 Fast Transients 3 Surge Immunity 4 Conducted Immunity 5 Radiated Immunity 6 Power Frequency Magnetic Field Variations Immunity Test 400VAC Only 8 Conducted Emissions EN55011A FCC part 15J A 9 Radiated Emissions EN55011A FCC part 15J A 2 5 SAFETY 1 Applicable Standards UL cUL 60950 1 EN60950 1 recognized CB Scheme CE Mark 208VAC amp 400VAC inputs only 7 5V lt Vout lt 400V Output i
7. 800V 1500V select models 15kW 30V 50V 800V 1500V 10kW 45 23 20 Vout lt 600V N A 23 20 800V lt Vout lt 1500V at full rated Output power A hout Gumeni 18QVAC S60 or G42 VAC AS2VAC 15kW 64 32 27 Vout lt 600V N A 32 27 800V lt Vout lt 1500V at full rated Output power 6 PowerFactor ossPassvelypica _8 Input Protection J 208VAC circuit breaker Vout lt 600V 400VAC 480VAC all models line fuse 9 Input Overvoltage Protection Unit shall not be damaged by line overvoltage of 120 nominal AC input voltage with maximum duration of 100usec lt 5 on Three Phase Input 2 2 POWER SUPPLY CONFIGURATION 1 Paral el Operation Up to four 4 identical units may be connected in Master Slave Mode with single wire connection 3 In Advanced Parallel feature the current of Master unit multiplied by number of units connected in parallel is available via digital interface and displayed on the front panel display of the Master unit Remote Analog current monitor of the Master is scaled to the Output current of the Master unit only 2 Series Operation Possible with external diodes Up to two identical units with total Output voltage not to exceed 600V from Chassis ground for Vor lt 600V not to exceed 1500V from Chassis ground for 600V lt Vor lt 1500V 2 3 ENVIRONMENTAL CONDITIONS 1 Operating Temperature 0 50 C 100 load 2 Storage Temperature 20
8. O O panom BOUDHREESDELOUDBSS2 Se SROUESS INDOSGOORE20 SS00m D l BSQOMOOOCSOS008BoGo0R200060 INOOOOOOESO S OOSSMODDOODOS00O0SR00000 80 DODDDODDODDDOB e SSMPmoOooonsooeoooooBoooRs Beeler eiaia DR S FES cing Bepon Enen 9 gagi o Oormisaran fanl mmm mmal Bon NC Ooo OOOGHDooeo O BStRRSRRaE DoDDBangaes 9 EnH aii Sods COU oo pomme oommoa NSO S00 Boas DOmoOO ERIE nmonmopooppamgumniaga SEE eee e BH D Le SEEEEEEES HE Oa ea FUNCTIONAL GROUND POSITIVE OUTPUT TERMINAL M5x 0 8 X 29 32 LONG THREADED STUD 23mm NEGATIVE OUTPUT TERMINAL 22 20 _ 230 2 30 563 88 58 45 58 42 7 g e ry Fy ly a a fo 0 fo 6 l p u 3 48 88 41 BE ao a be O B OODO00S00000000000000 000000000 OBE0M0000000000 GEESE 4 75 OTE 1 m 120 64 8 62 i 219 06 2 30 12 50 317 49 58 42 16 37 jis 415 91 z 20 25 7 514 34 NOTE 5 Ep NOTES m 3 php 1 Busbars for models up to 30V Output two holes 0 42 10 72mm diameter ai 2 Busbars for models 40 300V 10kW and 60 300V 15kW Output one hole 0 42 10 72mm diameter 3 Threaded stud terminal for models above 300V Output 4 Input Terminals M6 x 1 3 Ground M5 x 1 2 5 Mounting for Slide
9. Parallel Master Slave Hx Master unit where x of Slave units 0 to 4 S Slave unit s 2 Display Voltage 4 digits Accuracy 0 5 of Vo rated 1 count Current 4 digits Accuracy 0 5 of lo rated 1 count Voltmeter displays voltage at power supply Local sense or at load Remote sense Green LED s PREVIEW FOLD REM LOCAL OUT ON OFF CV CC FINE Red LED ALRM OVP OTP FOLD AC FAIL ENA SO 1 6 DIGITAL PROGRAMMING amp READBACK 1 Vout Programming Accuracy 0 5 of rated Output voltage 2 lout Programming Accuracy 0 5 of rated Output current for units with lo lt 187 5A 0 7 of rated Output current for lo gt 187 5A 3 Vout Programming Resolution 0 02 of Vo rated 4 lout Programming Resolution 0 04 of lo rated 5 Vout Readback Accuracy 0 1 of Vo actual 0 2 of Vo rated 6 lout Readback Accuracy 0 1 of lo actual 0 4 of lo rated 7 Vout Readback Resolution 0 02 of Vo rated 8 lout Readback Resolution 0 02 of lo rated 9 OV Response Time Oms maximum between Vout exceeding IEEE Limit and supply Inhibit turning On 10 Other Functions Set OVP UVL limits Set Local Remote Operating parameters and Status Get Identity 10 0 02 of Votate oo x 0 04 of lo rated TT 0 1 of Volactual 0 2 of Vo rated XY 0 1 of lo actual 0 4 of lo rated TX 0 02 of Vo rated s 0 02 of lofrated XT Set OVP UVL limits Set Local Remote Operating parameters an
10. RS 485 IEEE IEMD and LAN selection by rear panel DIP switch Baud rate selection RS 232 RS 485 only 1200 2400 4800 9600 and 19 200 by current adjust encoder Advanced Parallel Master Slave Hx Master unit where x of Slave units 0 to 4 Slave Slave unit s 2 Display Voltage 4 digits Accuracy 0 5 of Vo rated 1 count Current 4 digits Accuracy 0 5 of lo rated 1 count Voltmeter displays voltage at power supply Local sense or at load Remote sense 3 Indications Green LED s PREVIEW FOLD REM LOCAL OUT ON OFF CV CC FINE Red LED ALRM OVP OTP FOLD AC FAIL ENA SO 1 6 DIGITAL PROGRAMMING amp READBACK 1 Vout Programming Accuracy 0 5 of rated Output voltage X 2 lout Programming Accuracy 0 5 of rated Output current for units with lo lt 187 5A 0 7 of rated Output current for lo gt 1875A X 3 Vout Programming Resolution 0 02 of Vo rated X 4 lout Programming Resolution 0 04 of lo rated X 5 Vout Readback Accuracy 0 1 of Vo actual 0 2 of Vo rated X 6 lout Readback Accuracy 0 1 of Vo actual 0 4 of Vo rated X 7 Vout Readback Resolution 0 02 of Vo rated X 8 lout Readback Resolution 0 02 of lo rated X 9 OV Response Time 20mS maximum between Vout exceeding IEEE Limit and supply Inhibit turning On x 10 Other Functions Set OVP UVL limits Set Local Remote Operating Parameters and Status Get Identity X 800V 1500V models 10kW only available w
11. ppm C 200 0 02 of Vo Rated C 8 Up Prog Response Time 0 Vomax full load 9 Up Prog Response Time 0 Vomax no load 6 Temperature Stability 10 Transient Response Time CV mode 2 1 2 CONSTANT CURRENT MODE CC Less than 3 Less than 1 1 Max Line Reg 0 1 lor gt 333A 0 050 lor lt 333A 50 38 30 25 19 15 13 28 23 18 15 2 Max Load Reg 0 1 lor gt 333A 0 075 25A lt lor lt 333A 0 2 lor lt 25A 3 75 57 45 38 28 23 19 38 30 24 20 4 Temperature Stability ee 0 05 of lo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature x 300 0 03 of lolrated 1 C 1 3 PROTECTIVE FUNCTIONS 2 OCP type 3 Foldback Protection 4 Foldback Response Time 5 OVP type 6 OVP Programming Accuracy 7 OVP Trip Point 8 OVP response time 9 Max OVP reset time 10 Over temperature Protection 11 Phase Loss Protection 1 4 REMOTE ANALOG CONTROLS amp SIGNALS 1 Vout Voltage Programming 2 lout Voltage Programming 3 Vout resistor programming 4 lout Resistor Programming 5 Shut Off SO Control rear panel 6 Output Current Monitor 7 Output Voltage Monitor 8 Power Supply OK PS_OK Signal 9 CV CC Signal 10 Enable Disable 11 Remote Local Selection 12 Remote Local Signal 1 5 FRONT PANEL 1 Conti rol Functions 2 Display 3 Indications 1 6 DIGITAL PROGRAMMING amp READBACK 1 Vou 2 lou Progr
12. 0 250 50 200 60 167 80 125 100 100 1 Rated Output Voltage 75 10 12 5 20 25 30 40 50 60 80 100 125 2 Rated Output Current 1000 1000 800 500 400 333 250 200 167 125 100 80 3 Rated Output Power 0 75 100 100 100 100 100 100 100 100 10 0 10 0 10 0 4 Efficiency min at low AC line 100 Rated Load Contact Factory for other models 1 1 CONSTANT VOLTAGE MODE CV 1 Max Line Reg 0 1 Vor lt 30V 0 01 30V lt Vor lt 600V 0 05 600V lt Vor lt 1500V 2 Max Load Reg 0 1 Vor lt 30V 0 02 30V lt Vor lt 10 600V 0 1 600V lt Vor lt 1500V 6 Temperature Stability 0 05 of Vo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 200 0 02 of Vo Rated C 8 Up Prog Response Time 0 Vomax tuloa f ms ll XT 1 2 CONSTANT CURRENT MODE CC 1 Max Line Reg 0 1 lor gt 333A 0 050 17A lt lor lt 333A 0 15 lor lt 17A 1000 1000 800 500 400 333 125 100 83 5 62 5 50 40 2 Max Load Reg 0 1 lor gt 333A 0 075 17A lt lor lt 333A 0 2 lor lt 17A 3 1000 1000 800 500 400 333 188 150 125 94 75 60 67 50 40 32 3 Ripple rms 5Hz 1MHz CC 5300 4000 2560 1000 640 444 250 160 4 Temperature Stability 0 05 of lo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 300 0 03 of lo Rated C 1 3 PROTECTIVE FUNCTIONS 2 OCPtpe Constantcurrent XT s Foldback
13. 7A 2 Max Load Reg 0 1 lor gt 333A 0 075 17A lt lor lt 333A 0 2 lor lt 17A 3 3 Ripple rms 5Hz 1MHz CC 26 20 16 13 10 8 7 15 10 6 4 4 Temperature Stability 0 05 of lo Rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 5 Temperature Coefficient ppm C 300 0 03 of lo Rated C 1 3 PROTECTIVE FUNCTIONS aocpgte osmom gt _3 Foldback Protection FOLD Output shut down Manual reset by front panel OUT button or Digital communication user selectable x Less than 1 Min 0 25 Max 25 Default 0 25 Settable via FBD command 5 OVP type _ Inverter shut down Manual reset by AC On Off recycle OUT button Remote Analog or Digital comm X 6 OVP Programming Accuracy 5 of Vo rated 5 to 105 of Vo rated for Vor lt 600V 10 to 105 of Vo rated 600V lt Vor lt 1500V Shall always be greater than 105 of Vo setting Default 105 of Vo rated Less than 10 for Output to begin to drop for Vor lt 600V Less than 2 0 for Output to begin to drop for 8 OVP response time 600V lt Vor lt 1500V 9 Max OVP reset time 7 from AC On Off switch turn On 10 Over Temperature Protection OTP Shut down if internal temperature exceeds safe operating levels Latched Safe Unlatched Auto 11 Phase Loss Protection Yes power supply shutdown Latched Safe mode Unlatched Auto mode
14. Identity 30V 40V and 50V models 15kW only available with 400VAC and 480VAC For 208VAC Input models please contact the factory 1 Ripple and Noise at Vo rated and rated Load Ta 25C and nominal AC input per ElJ R9002A 2 Time for the Output voltage to recover within 2 of rating for a load current change of 50 100 or 100 50 of rated Output 3 From 20 100 for models with lor lt 25A All specifications subject to change without notice 5 Genesys 3U 10 15kW Genesys 3U 15kW Specifications 1 0 MODEL GEN 150 100 200 75 250 60 300 50 400 375 500 30 600 25 800 18 8 1000 15 1250 12 1500 10 150 200 250 300 400 500 600 800 1000 1250 1500 wo 75 60 60 3 0 2 8 CCS 15 0 15 0 150 150 150 150 15 0 15 04 15 0 15 0 15 0 1 1 CONSTANT VOLTAGE MODE CV 1 Max Line Reg 0 1 Vor lt 30V 0 01 30V lt Vor lt 600V 0 05 600V lt Vor lt 1500V 2 Max Load Reg 0 1 Vor lt 30V 0 02 30V lt Vor lt 600V 0 1 600V lt Vor lt 1500V 3 Ripple rm s 5Hz 1MHz CV 1 25 35 35 60 60 60 60 80 100 120 140 4 Output Noise p p 20MHz CV 1 5 Remote Sense Compensation Wire Contact Factory for other models 15 20 25 30 40 50 60 400 500 625 750 30 40 50 60 80 100 120 800 1000 1250 1500 150 175 200 200 300 350 350 700 800 1000 1400 0 05 of Vo Rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 7 Temperature Coefficient
15. Mounts not included Recommend General Devices Chassis Trak P N C230 S 122 Secure with pan head screw M5 x 0 8 8mm long max 9 Genesys 3U 10 15kW Outline Drawings Genesys 15kW 30V to 50V 400VAC 480VAC POSITIVE 19 00 482 60 an ON 5 _ OUTPUT TERMINAL NEGATIVE OUTPUT TERMINAL 22 85 580 39 DOSeeBS000058 80 BGESRSSogSooo00 EEEIEE EEE ooempnpnonanssss COBSBeEoooo Oopo0008so000 Ooooo0oo0000 Deeeeooooo SBSSSSs00o0000o000 EDDDoooooooooooao Goooooooooooogog EDoooooooooooooaol cpoooooooooo 4 75 120 65 8 63 219 08 12 50 317 50 NOTES 1 N A 2 3 N A 4 5 NOTE 5 16 38 415 93 Input Terminals M6 x 1 3 Ground M5 x 1 2 Mounting for Slide Mounts not included Recommend General Devices Chassis Trak P N C230 S 122 Secure with pan head screw M5 x 0 8 8mm long max TE 1 FUNCTIONAL GROUND M5x0 8 X 29 32 LONG THREADED STUD 23
16. Protection FOLD Output shutdown Manual reset by front panel OUT button or Digital communication userselectable x Less than 1 Min 0 25 Max 25 Default 0 25 Settable via FBD command 5 OvPtype TT Inverter shut down Manual reset by AC On Off recycle OUT button Remote Analog or Digital commuincation X v 5 to 105 of Vo rated for Vor lt 600V 10 to 105 of Vo rated 600V lt Vor lt 1500V Shall always be greater than 105 of Vo setting Default 105 of Vo rated 8 OVP Response Time Less than 10 for Output to begin to drop for Vor lt 600V Less than 2 0 for Output to begin to drop for x mS soov lt Vor lt 1500V 9 Max OVP Reset Time s 7 from AC On Off switch turn On 10 Over Temperature Protection OTP Shut down if internal temperature exceeds safe operating levels Latched Safe mode Unlatched Auto mode 11 Phase Loss Protection Yes power supply shutdown Latched Safe mode Unlatched Auto mode 1 4 REMOTE ANALOG CONTROLS amp SIGNALS 1 Vout Voltage Programming 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of Vo rated 2 lout Voltage Programming 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of lo rated 3 Vout Resistor Programming 0 100 0 5 10kohm full scale user selectable Accuracy amp Linearity 1 of Vo rated 4 lout Resistor Programming 0 100 0 5 10kohm full scale user selec
17. Republic of Korea 137 862 Tel 82 2 3473 7051 4 Fax 82 2 3472 9137 Email BS Bang kr tdk lambda com Web www tdk lambda co kr MALAYSIA TDK Lambda Malaysia Lot 709 Nilai Industrial Estate 71800 Nilai Negeri Sembilan Tel 60 6 799 1130 Fax 60 6 799 3277 www my tdk lambda com SINGAPORE PHILIPPINES THAILAND TDK Lambda Singapore 1008 Toa Payoh North 06 01 08 Singapore 318996 Tel 65 6251 7211 Fax 65 6250 9171 Email anthony lau sg tdk lambda com Web www sg tdk lambda com TDK Lambda India No 989 1st Cross 2nd Floor 13th Main HAL 2nd Stage Bangalore Karnataka India 560 008 Tel 91 80 43550500 Fax 91 80 43550501 Email mathew philip in tdk lambda com Web www in tdk lambda com ISRAEL Russia Kibbutz Givat Hashlosha Tel Aviv 48800 Tel 972 3 9024 333 Fax 972 3 9024 777 E mail info tdk lambda co il Web www tdk lambda co il Part No 93 530 001 Rev K
18. V mode 2 1 2 CONSTANT CURRENT MODE CC ms ms ms 1 Max Line Reg 0 1 lor 333A 0 050 lor lt 333A mA ma 2 Max Load Reg 0 1 lor gt 333A 0 075 25A lt lor lt 333A 0 2 lor lt 25A 3 _4 Temperature Stability 0 05 oflo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 300 0 03 of lo rated C 1 3 PROTECTIVE FUNCTIONS 2 0CPtype Constant current XT 3 Foldback Protection FOLD Output shutdown Manual reset by front panel OUT button or Digital communication user selectable X _4 Foldback Response Time s Less than 1 Min 0 25 Max 25 Default 0 25 Settable via FBD command 5 0VPtype Inverter shut down Manual reset by AC On Off recycle OUT button Remote Analog or Digital communication X 5 of Vo rated ae 5 to to 105 of Vo rated for Vor lt 600V 10 to 105 of Vo rated 600V lt Vor lt 1500V Shall always be x TONE inp Point greater than 105 of Vo setting Default 105 of Vo rated ms n Less than 10 for Output to begin to drop for Vor lt 600V Less than 2 0 for Output to begin to drop for 8 OVP Response Time ms 600V lt Vor lt 1500V X 9 Max OVP Reset Time s 7 from AC On Off switch turn On 10 Over temperature Protection OTP Shut down if internal temperature exceeds safe operating levels Latched Safe mode Unlatched Auto mode 11 Phase L
19. amming Accuracy Programming Accuracy 3 Vout Programming Resolution 4 lou Programming Resolution 5 Vout Readback Accuracy Constant current Output shut down Manual reset by front panel OUT button or Digital communication user selectable Less than 1 Min 0 25 Max 25 Default 0 25 Settable via FBD command 5 of Vo rated 5 to to 105 of Vo rated for Vor lt 600V 10 to 105 of Vo rated 600V lt Vor lt 1500V Shall always be greater than 105 of Vo setting Default 105 of Vo rated Less than 10 for Output to begin to drop for Vor lt 600V Less than 2 0 for Output to begin to drop for 600V lt Vor lt 1500V 7 from AC On Off switch turn On Shut down if internal temperature exceeds safe operating levels Latched Safe Unlatched Auto Yes power supply shutdown Latched Safe mode Unlatched Auto mode 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of Vo rated 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of lo rated 0 100 0 5 10kohm full scale user selectable Accuracy amp Linearity 1 of Vo rated 0 100 0 5 10kohm full scale user selectable Accuracy amp Linearity 1 of lo rated By Voltage 0 6V Disable 2 15V Enable default or Dry Contact Open EN Short DIS user selectable logic 0 5V or 0 10V Accuracy 1 of lo rated user selectable 0 5V or 0 10V Accuracy 1 of Vo rated user se
20. ated Output current for lo gt 1875A 0 02 of Vo rated 0 04 of lo rated 0 1 0 2 of rated Output voltage 6 lout Readback Accuracy 0 1 0 4 of rated Output current 7 Vout Readback Resolution 0 02 of Vo rated 8 lout Readback Resolution 0 02 of lo rated 9 OV Response Time 20mS maximum between Vout exceeding OVP Limit and supply inhibit turning On 10 Other Functions Set OVP UVL limits Set Local Remote Operating parameters and Status Get Identity gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt lt 800V 1500V models 15kW only available with 400VA and 480VAC input For 208VAC Input models please contact the factory 1 Ripple and Noise at Vo rated and rated Load Ta 25C and nominal AC input per ElJ R9002A 2 Time for the Output voltage to recover within 2 of rating for a load current change of 50 100 or 100 50 of lo rated 3 From 20 100 for models with lor lt 25A All specifications subject to change without notice TDK Lambda le General Specifications Genesys 3U 10kW 15kW 2 1 INPUT CHARACTERISTICS 1 Input Voltage Frequency range 208VAC 180 253 400VAC 360 440 342 440 select 10kW 15kW models 480VAC 432 528 47 63Hz all 2 No of phases 3 Phase Wye or Delta 4 wire total 3 Phase and 1 protective Earth ground 3 Dropout Voltage 180 360 342 select models 432 select models 10kW
21. d CE Mark for LVD and EMC Regulation 208VAC 400VAC and select 480VAC models Five Year Warranty U Wu CE Applications Genesys power supplies are designed for demanding applications Test amp Measurement systems using GPIB control save significant costs by incorporating the optional IEEE Multi Drop Interface IEMD in the Master unit Then up to 30 Slave units may be used with the standard RS 485 Multi Drop interface Automated System designers will appreciate new standard remote programming features such as Global commands Also new high speed status monitoring is available for the RS 485 bus as well as the optional LAN LXI compliant Interface Industrial amp Military high power systems can be configured with up to four identical units in parallel up to 60kW No space is required above or below each power supply zero stack The Master unit can be configured by the user to report the total Output current of the combined system Applications include Heaters Magnets and Laser Diodes Aerospace amp Satellite Testing systems use the complete Genesys Family 1U 750W Half Rack 1U 750W 1 5kW 2 4kW Full Rack 2U 3 3kKW 5kW Full Rack and 3U 10kW 15kW Full Rack All are identical in Front Panel Rear Panel Analog and Digital Interface Commands A wide variety of Outputs voltage and current allows testing of many different user configurations Component Device Testing is simplified because of the many user friendly contr
22. d Status Get Identity X 1 Ripple and Noise at Vo rated and rated Load Ta 25C and nominal AC input per EIJ R9002A 2 Time for the Output voltage to recover within 2 of rating for a load current change of 50 100 or 100 50 of lo rated 3 From 20 100 for models with lor lt 17A All specifications subject to change without notice 3 Genesys 3U 10 15kW Genesys 3U 10kW Specifications 1 0 MODEL 66 200 50 250 40 300 33 400 25 500 20 600 17 800 12 5 1000 10 1250 8 1500 6 7 1 Rated Output Voltage 150 200 250 300 400 500 600 800 1000 1250 1500 2 Rated Output Current 66 50 40 33 25 20 17 12 5 10 8 0 6 7 3 Rated Output Power 99 100 100 99 10 0 10 0 102 10 0 10 0 10 0 10 0 4 Efficiency min at low AC line 100 Rated Load 1 1 CONSTANT VOLTAGE MODE CV Contact Factory for other models 1 Max Line Reg 0 1 Vor lt 30V 0 01 30V lt Vor lt 600V 0 05 600V lt Vor lt 1500V 50 500 625 750 500 x 2 Max Load Reg 0 1 Vor lt 30V 0 02 30V lt Vor lt 600V 0 1 6 lt Vor lt 1500V 190 300 1000 1250 i 150 175 200 200 300 350 350 700 800 1000 1400 6 Temperature Stability 0 05 ofVo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature 7 Temperature Coefficient ppm C 200 0 02 of Vo Rated C X 1 2 CONSTANT CURRENT MODE CC 1 Max Line Reg 0 1 lor gt 333A 0 050 17A lt lor lt 333A 0 15 lor lt 1
23. d two hole Greater than 300V models M6 x 0 5 threaded stud terminals Analog Programming DB25 plastic connector AMP747461 5 Female on Supply Male on Mating connector 747321 25 pin Sub D connector 7 Mounting Method Standard 19 Rack Mount provision for standard chassis slides Side Rear Support is required Do not mount by front panel only 8 Output Ground Connection M5 x 1 0 threaded stud 2 7 WARRANTY 1 Warranty 5 years 3 GENESYS 30V 50V 15kW and 800V 1500V 10kW 15kW mdoels require a Two Wire Parallel Master Slave connection See the Product USer s Manual for details 4 30V 50V 15kW and 800V 1500V 10kW 15kW models with 480VAC Input have CE Mark All specifications subject to change without notice IIl F J i Ds 7 Genesys 3U 10 15kW Genesys Power Parallel and Series Configurations Parallel operation Master Slave Active current sharing allows up to four identical units to be connect ed in an Auto parallel configuration for four times the Output power In Advanced Parallel Master Slave Mode total current is pro grammed and reported by the Master Up to four supplies act as one Series operation Up to two units may be connected in series to increase the Output voltage or to provide bipolar output Max 600V to Chassis GND for Vor lt 600V Max 1500V to Chassis GND for 600V lt Vor lt 1500V Remote Programming via RS 232 amp RS 485 Interface
24. ith 400VA and 480VAC input For 208VAC Input models please contact the factory 1 Ripple and Noise at Vo rated and rated Load Ta 25C and nominal AC input per ElJ R9002A 2 Time for the Output voltage to recover within 2 of rating for a load current change of 50 100 or 100 50 of lo rated 3 From 20 100 for models with lor lt 17A All specifications subject to change without notice TDK Lambda 4 Genesys 3U 15kW Specifications 1 0 MODEL GEN NA NA NA NA NA 30 500_40 375 50 300 60 250 60 1875 100 150 125120 1875160 Raed Output Power kw 15 0 150 150 150 150 150 4 Efficiency min at low AC line 100 Rated Load Contact Factory for other models 1 1 CONSTANT VOLTAGE MODE CV 1 Max Line Reg 0 1 Vor lt 30V 0 01 30V lt Vor lt 600V 0 05 600V lt Vor lt 1500V 2 Max Load Reg 0 1 Vor lt 30V 0 02 30V lt Vor lt 600V 0 1 600V lt Vor lt 1500V 3 Ripple rms 5Hz 1MHz CV 1 mV 4 Output Noise p p 20MHz CV 1 mv 5 Remote Sense Compensation Wire 1 5 2 3 3 4 5 5 6 Temperature Stability 0 05 of Vo rated over 8 hours after 30 minute warm up constant Line Load amp Temperature k m m m m 7 Temperature Coefficient ppm C 200 0 02 of Vo rated C 8 Up Prog Response Time 0 Vomax full load i 9 Up Prog Response Time 0 Vomax no load Less than 3 10 Transient Response Time C
25. lass C P N LAN Meets all LXI Class C Requirements VISA amp SCPI Compatible Address Viewable on Front Panel e LAN Fault Indicators Fixed and Dynamic Addressing e Auto detects LAN Cross over Cable e Fast Startup Compatible with most standard Networks TDK Lambda ls Outline Drawings Genesys 10kW All 208VAC 10kW 15kW 60V to 600V 208 400 480VAC 19 00 482 60 o i HE AO fo E im BE So Bo Re OS o mrp OO QO OO ee mn 5 22 j r ne 132 59 MES fo Oo 16 90 16 90 E 429 26 ie 429 26 ara E gH fang E na Eee m gE eE BAG D EE B BE Baoo INGOGEOO00es SOMOOnoO mi no Boano ar secccoooomea tee INDOOOOO0zZSas8
26. lectable Yes TTL High OK OV Fail 500ohm series impedance CV TTL High 4 5V Max source current 10mA CC TTL Low 0 0 4V Max sink current 10mA Dry contact Open Off Short On Max voltage across Enable Disable contacts 6V Selects Remote or Local operation by voltage 0 0 6V Local 2 15V Remote Signals operating mode Open collector Local Open Max voltage 30V Remote On Max sink current 10mA D Vout lout manual adjust by separate encoders coarse and fine adjustment selectable OVP UVL manual adjust by Voltage Adjust encoder Front Panel Lock Unlock Address selection by Voltage Adjust encoder of addresses 31 AC ON OFF Output On Onn Restart Modes Auto Safe Foldback Control CV to CC Go to Local RS232 RS 485 IEEE IEMD and LAN selection by rear panel DIP switch Baud rate selection RS 232 RS 485 only 1200 2400 4800 9600 and 19 200 y current adjust encoder Advanced Parallel Master Slave Hx Master unit where x of Slave units 0 to 4 S Slave unit s Voltage 4 digits Accuracy 0 5 of Vo rated 1 count Current 4 digits Accuracy 0 5 of lo rated 1 count Voltmeter displays Voltage at power supply Local sense or at load Remote sense Green LED s PREVIEW FOLD REM LOCAL OUT ON OFF CV CC FINE Red LED ALRM OVP OTP FOLD AC FAIL ENA SO 0 5 of rated Output voltage 0 5 of rated Output current for units with lo lt 187 5A 0 7 of r
27. mbda com SCANDINAVIA BALTICS TDK Lambda Germany Karl Bold Str 40 D 77855 Achern Tel 49 7841 666 0 Fax 49 7841 500 0 E mail info de tdk lambda com Web www de tdk lambda com TDK Lambda Americas Inc 405 Essex Road Neptune NJ 07753 USA AN i DK Tel 1 732 922 9300 Fax 1 732 922 1441 www us tdk lambda com hp TDK Logo is a trademark or registered trademark of TDK Corporation Copyright 2014 TDK Lambda Americas Inc JAPAN TDK Lambda Corporation International Sales Division 3 9 1 Shibaura Minato ku Tokyo 108 0023 Tel 81 3 6852 7136 Fax 81 3 6852 7148 E mail momata jp tdk lambda com Web www jp tdk lambda com TDK Lambda Shanghai Office 28F Xingyuan Technology Building No 418 Guiping Road Shanghai 200233 P R CHINA Tel 86 21 6485 0777 Fax 86 21 6485 0666 E mail sales sh cn tdk lambda com Web www cn tdk lambda com TDK Lambda Beijing Office Room 12B11 12B12 Unit 7 DACHENG SQUARE No 28 Xuanwumenxi Street Xuanwu District Beijing 100053 P R CHINA Tel 86 10 6310 4872 Fax 86 10 6310 4874 E mail sales bj cn tdk lambda com Web www cn tdk lambda com TDK Lambda Hong Kong Office 1 F SAE Technology Centre 6 science Park East Avenue HongKong Science Park Shatin NT Tel 852 23766658 Fax 852 23172150 E mail sales hk hk tdk lambda com Web www cn tdk lambda com TDK Lambda Corporation Seocho Dong 8F Songnam Bldg 273 Gangnam Daero Seocho Gu Seoul 137 862
28. mm 250 63 45 0 422 THRU 10 72 p U 2 70 68 49 4NOTE 2 1 10 28 05 ie OO OOOOOCOo 38 Bus bars for models 30 50V Output 15kW one hole 0 42 10 72mm diameter TDK Lambda mo Outline Drawings Genesys 15kW 800V to 1500V 400VAC 480VAC 5 22 132 59 16 90 i 429 26 g x oC e ig o BE COO CCSSte SS hSSsceeSHSeese ESEEBBHL o EEEE EEEHEE ee Penn OSSSHSSSESSS5n8 BeSaEeseaaaee BD REEEbeeeeeeeemiG OEEEEEEEEESOEEE fo ITIGEES TEES ARES Sia apsanseed eO MHI BAHEA i e oe POSITIVE OUTPUT TERMINAL FUNCTIONAL GROUND NEGATIVE OUTPUT TERMINAL M5x0 8 X 29 32 LONG THREADED STUD 23mm 2 00 22 85 T z 580 39 gggogggpggpogog ell peansssagoggEpes SOOWEOo0O090009 mi e eset i 8 9 gooopess588 Bobpanoaooo DOoaonooooo P 3 48 88 46 ee f Doaeamooooggoooooogoo AGSESESSOSCOoORSoocdD 4 75
29. n Status LEDs e Alarm Fine Control Preview Settings Foldback Mode Remote Mode Output On Pushbuttons allow flexible user configuration e Coarse and Fine adjustment of Output Voltage Output Current and Advanced Parallel Master or Slave select Preview Settings and set Voltage Current with Output OFF Front Panel Lock Parallel Master Slave Basic and Advanced Set OVP and UVL Limits Set Current Foldback Protection Go to Local Mode and select Address and Baud rate Output ON OFF and Safe Start Auto Re Start mode Rear Panel Description OnoOD oo mA Remote Local Output Voltage Sense Connections DIP Switches select 0 5V or 0 10V Programming and other functions DB25 Female connector allows Analog Program and Monitor non isolated and other functions RS 485 OUT to other Genesys Power Supplies RS 232 RS 485 IN Remote Serial Programming Output Connectors Rugged 2 hole busbars shown for models lt 30V Output single hole busbars for 30V to 300V Output and threaded stud terminals for models gt 300V Output Exit air assures reliable operation when zero stacked Input Terminals L1 L2 L8 and Ground threaded studs Optional Interface Position for LAN LXI Class C GPIB IEEE 488 2 SCPI or Isolated Analog Interface LAN Interface complies with LXI Class C Specification TDK Lambda 2 Genesys 3U 10kW Specifications 1 0 MODEL GEN 75 1000 10 1000 12 5 800 20 500 25 400 30 333 4
30. ol options in the Analog and Digital interfaces Lamps capacitors motors and actuators are typical devices tested Medical Imaging and Treatment systems require reliable power Modular construction SMT and thoroughly proven designs assure continuous performance at full rated power Semiconductor Processing amp Burn in equipment designers appreciate the wide variety of worldwide AC Inputs and Outputs from which to select depending on application Selectable Safe Start and Auto Re Start protects loads and process integrity Typical applications include Magnets Filaments and Heaters 1 Genesys 3U 10 15kW Front Panel Description NOoR OD O TDK Lambda A ESD en amp Sas i Ca ios a 7 n gt Gee Se ee e e a a ee aea ee ee ED ees SEES Eee CEP EENEEED ees eS ee ee css sms esr ers mrsnssn eee DO ee em ees eee Gee se eee QM ee al a aao aa auMlM AC ON OFF Switch Air Intake allows zero stacking for maximum system flexibility and power density Continuous encoder controls Output Voltage Address OVP and UVL settings Voltage Display shows Output Voltage and directly displays OVP UVL and Address settings Continuous encoder controls Output Current sets Baud rate and Advanced Parallel mode Current Display shows Output Current and displays Baud rate Displays total current in Parallel Master Slave Mode Functio
31. options P N RS 232 RS 485 Multi Drop Interface built in Standard oo LAN Interface LMJ Class C compliant LAN GPIB Multi Drop Master Interface IEMD Voltage Programming Isolated Analog Interface 1S510 standard on 800 1500V models Current Programming Isolated Analog Interface 1S420 Accessories 1 Serial Communication cable RS 232 RS 485 cable is used to connect the power supply to the Host PC Mode RS 485 RS 232 RS 232 Communication Cable Shield Ground L 2m Shield Ground L 2m Shield Ground L 2m Power Supply Connector __EIA TIA 568A RJ 45 EIA TIA 568A RJ 45 EIA TIA 568A RJ 45 GEN 485 9 GEN 232 9 GEN 232 25 2 Serial Link cable Daisy chain up to 31 Genesys power supplies Modes Power Supply Connector Communication Cable P N RS 485 EIA TIA 568A RJ 45 Shield Ground L 50cm GEN RJ45 Included with GENESYS 1U 2U power supply only TDK Lambda 12 Genesys Family Output Voltage Output Current 4 Available in 400VAC and 480VAC input For 208VAC input please contact the factory AC Inputs 1 UL Listed CE Mark ROHS 2 UL Recognized CE Mark 3 UL Recognized only CE Mark for select 10kW 800V 1500V and 15kW 30V 50V and 800V 1500V models Options All Models All options are factory installed and limited to one per power supply All specifications subject to change without notice 13 Genesys 3U 10 15kW TDK Lambda GLOBAL NETWORK TDK Lambda Americas Inc 405 Es
32. oss Protection Yes power supply shutdown Latched Safe mode Unlatched Auto mode 1 4 REMOTE ANALOG CONTROLS amp SIGNALS 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of Vo rated 0 100 0 5V or 0 10V user selectable Accuracy amp Linearity 1 of lo rated 3 Vout Resistor Programming 4 lout Resistor Programming 5 Shut Off SO Control rear panel By Voltage 0 6V Disable 2 15V Enable default or Dry Contact Open EN Short DIS user selectable logic 6 Output Current Monitor 7 Output Voltage Monitor 8 Power Supply OK PS_OK Signal Yes TTL High OK OV Fail 500ohm series impedance 9 CV CC Signal CV TTL High 4 5V Max source current 10mA CC TTL Low 0 0 4V Max sink current 10mA 10 Enable Disable Dry contact Open Off Short On Max voltage across Enable Disable contacts 6V 11 Remote Local Selection Selects Remote or Local operation by voltage 0 0 6V Local 2 15V Remote 12 Remote Local Signal Signals operating mode Open collector Local Open Max voltage 30V Remote On Max sink current 10mA 1 5 FRONT PANEL 1 Control Functions Vout lout manual adjust by separate encoders coarse and fine adjustment selectable OVP UVL manual adjust by Voltage Adjust encoder Front Panel Lock Unlock Address selection by Voltage Adjust encoder of addresses 31 AC ON OFF Output On Off Restart Modes Auto Safe Foldback Control CV to CC
33. s Hazardous LAN IEEE Isolated Analog USB are SELV 400V lt Vout lt 600V Output is Hazardous LAN IEEE Isolated Analog USB are not SELV 600V lt Vout lt 1500V Output is Hazardous LAN IEEE Isolated Analog USB are SELV 2 Withstand Voltage Vout lt 300V models Input Ground 2900VDC for 1min Input Hazardous Output 3500VDC for 1min Input SELV 2900VDC for 1min Hazardous Output SELV 2121VDC for 1min Hazardous Output Ground 2121VDC for 1min 300 lt Vout lt 600V models Input Ground 2900VDC for 1min Input Hazardous Output 3900VDC for 1min Input SELV 2900VDC for 1min Hazardous Output SELV 2688VDC for 1min Hazardous Output Ground 2688VDC for 1min 600 lt Vout lt 1500V models Input Ground 2900VDC for 1min Input Hazardous Output 5040VDC for 1min Input SELV 2900VDC for 1min Hazardous Output SELV 2500VDC for 1min Hazardous Output Ground 2500VDC for 1min 3 Insulation Resistance gt 100Megohms at 500VDC 25 C 2 6 MECHANICAL CONSTRUCTION Fan driven Airflow from front to rear Supplemental vents on side that shall not be blocked EIA Rack mounting stackable Zero Stackable top and bottom Chassis slides or suitable rear support required Width 429mm 16 97 Height 3U 133mm 5 22 Depth 564mm 22 2 excluding connectors encoders handles etc 32kg 70lbs 3 x M6 x 1 threaded studs L1 L2 L3 and Chassis GND and terminal cover Up to and including 300V models bus bars one an
34. sex Rd Neptune NJ 07753 Tel 1 732 922 9300 Fax 1 732 922 1441 E mail sales us tdk lambda com www us tdk lambda com hp CANADA ACA TMetrix 5805 Kennedy Road Mississauga Ontario L4Z 2G3 Tel 1 800 665 7301 Fax 1 905 890 1959 Email lambda aca ca Web tmetrix com MEXICO AcMax de Mexico 39 Poniente 3515 Piso 5 Col Las Animas Puebla Pue C P 72400 Tel 01 800 211 0060 222 891 8484 Fax 222 264 1445 Email info acmax mx Web www acmax mx BRAZIL Supplitec Rua Sena Madureira 455 Belo Hte 31340 000 Tel 55 31 3498 1177 Fax 55 31 3441 0841 Email vendas suplitec com br Web www suplitec com br uk ietand O TDK Lambda UK Kingsley Avenue Ilfracombe Devon EX 34 8ES Tel 44 1271 856666 Fax 44 1271 864894 E mail powersolutions uk tdk lambda com Web www uk tdk lambda com FRANCE NETHERLANDS SPAIN TDK Lambda France ZAC des Delaches CS 41077 9 rue Thuillere 91978 Villebon Courtaboeuf Tel 33 1 60 12 71 65 Fax 33 1 60 12 71 66 Email france fr tdk lambda com Web www fr tdk lambda com GERMANY AUSTRIA SWITZERLAND TDK Lambda Germany Karl Bold Str 40 D 77855 Achern Tel 49 7841 666 0 Fax 49 7841 500 0 E mail info de tdk lambda com Web www de tdk lambda com ITALY TDK Lambda Italy Via dei Lavoratori 128 130 IT 20092 Cinisello Balsamo MI Tel 39 02 6129 3863 Fax 39 02 6129 0900 E mail info italia it tdk lambda com Web www it tdk la
35. table Accuracy amp Linearity 1 of lo rated 5 Shut Off SO Control rear panel By Voltage 0 6V Disable 2 15V Enable default or Dry Contact Open EN Short DIS user selectable logic 6 Output Current Monitor 0 5V or 0 10V Accuracy 1 of lo rated user selectable 7 Output Voltage Monitor 0 5V or 0 10V Accuracy 1 of Vo rated user selectable 8 Power Supply OK PS_OK Signal Yes TTL High OK OV Fail 500ohm series impedance 9 CV CC Signal CV TTL High 4 5V Max source current 10mA CC TTL Low 0 0 4V Max sink current 10mA 10 Enable Disable Dry contact Open Off Short On Max voltage across Enable Disable contacts 6V 11 Remote Local Selection Selects Remote or Local operation by voltage 0 0 6V Local 2 15V Remote 12 Remote Local Signal Signals operating mode Open collector Local Open Max voltage 30V Remote On Max sink current 10mA 1 5 FRONT PANEL 1 Control Functions Vout lout manual adjust by separate encoders coarse and fine adjustment selectable OVP UVL manual adjust by Voltage Adjust encoder Front Panel Lock Unlock Address selection by Voltage Adjust encoder of addresses 31 AC ON OFF Output On Off Restart Modes Auto Safe Foldback Control CV to CC Go to Local RS 232 RS 485 IEEE IEMD and LAN selection by rear panel DIP switch Baud rate selection RS 232 RS 485 only 1200 2400 4800 9600 and 19 200 by current adjust encoder Advanced
Download Pdf Manuals
Related Search
Related Contents
ET 8 and 12 QUICK PROGRAMMING GUIDE LanTEK II 350 Uniden G955 Owner's Manual User`s Guide French 3 NOKIA 5500-PTI - Alphacom Group MS-Tech LC-04B computer case Electric Solid Plate Hob Juliane Berwig - Biblioteca Unisinos Manual de instrucciones Samsung ND220HHXCE Manual de Usuario Copyright © All rights reserved.