        User Manual MPPT SOLAR CHARGER 3KW
         Contents
1.                                                 14  S 2 Eduallz   Stages stique aa Eo Mu v Ves FU OE c ibo Mea e e eins 16  5 3 Setting Parameter and Default                                                                           19      TROUBLE SHOOTING ws cui TT             20  Fe        ON                                          ee ea 21    1 ABOUT THIS MANUAL  1 1 Purpose    This manual describes the assembly  installation  operation and troubleshooting of    this unit  Please read this manual carefully before installations and operations     Keep this manual for future reference   1 2 Scope    This manual provides safety and installation guidelines as well as information on    tools and wiring   1 3 SAFETY INSTRUCTIONS    1     10     WARNING  This chapter contains important safety and operating  instructions  Read and keep this manual for future reference    Before using the unit  read all instructions and cautionary markings on the unit   the batteries and all appropriate sections of this manual    Do not disassemble the unit  Take it to a qualified service center when service  or repair is required  Incorrect re assembly may result in a risk of electric shock  or fire    To reduce risk of electric shock  disconnect all wirings before attempting any  maintenance or cleaning  Turning off the unit will not reduce this risk   CAUTION   Only qualified personnel can install this device with battery   NEVER charge a frozen battery    For optimum operation of this charger 
2.       LED Indicator    Solid On   The controller is on     The controller is charging     POWER ON    Bulk charge stage  flashing every 0 5 second  reen    CHARGING Flashing   Absorption stage  flashing every second    Equalize stage  flashing every 3 seconds    Float stage  flashing every 5 seconds       11       Solid On   Fault occurs   FAULT  WARNING Solid on      Flashing   Warning situation occurs     WIRING FAULT Solid On   Battery polarities are not connected correctly   Operation Button      Function   Action Description  Press the button until LCD backlight is on     If equalization function is enabled  press the button for 3 seconds    Equalization until LCD shows       7    to activate battery equalization immediately     enable disable If battery equalization is activated  press the button for 3 seconds                 until the          disappeared to cancel it     Backlight on Press shortly    4 2 LCD Display Icons   ioa  0101001  OU  INPUT  SOLAR PANEL        em am am Volt  wIRINGFAULT  Ll                         A AA    BATTERY VOLTAGE BATT  CAPACITY CHARGING CURRENT       den    Function description  Input Source Information    C cu      L4 LI LI Indicates the PV input voltage     INPUT  SOLAR PANEL     Configuration Program and Fault Information  EV    Indicates battery equalization is activated     Indicates fault codes     BH    Indicates warning codes   Output Information    1010105    1 7 1 H Indicate battery voltage     BATTERY VOLTAGE                t
3.    MPPT SOLAR CHARGER          PCM60X       CONTENTS    1 ABOUT  MATS MANUAL                   n            Ra aS    A DIOE LL PUES 1                       emp ID DR 1  1 2                 tudin s eu mE d c E MUI ed EE 1       SAFEERC INSTRUCTIONS      exis eui toe on               1  Z INTRODUCTION MP E 2  2  F eatre              et a Ecc NOD t UD elie a totale C DOO ICE NCC        2  2 2 Product                                            3  cM CIDIBE RIS CL          4  3 1  UnpackIhng        INSHSCHOM               etait cv i                 Cc i Da stt ua d a P Duda 4  SPAN                E UU te T EN 4                  Cie UNIE              ey carotid uc uoa eri ov md Rl Darei a riis au 4                                                               aN 5  3 5 Grounding and Ground Fault Interruption                                             7  2 0 Remote Temperature  SENSON                 tee ees one         7  3 7 Battery Voltage Sense   sessanta os             CN QU d               8  3 0 Communicalloh COnrecbloris x ses  ccs Ea v ar eei e eem a eoe bei                  9   dT OPERATION                       beau         M IS C            DIM E On M den DUE 11  izle e c ET 11  4 2 Operation and Display Panel                        sese nnn nnn 11  42 LCD                    RE T TT 12  753 Reference COGG xo oo oe xe ndo Mea De Vo ir ed a Elie Urn ulti pdt Da 13  5 CHARGING LOGIC                                                                         14  JLo Sage Charn 
4.   _ l     f  Hm Indicate charging power                               111 Tur Indicate charging current   CHARGING C Ll  Indicates battery level by 0 24   25 49   50 74  and    0 LLL 75 100  in battery mode and charging status in line    BATT  CAPACITY mode     Battery Charging Status     Battery voltage LCD Display     lt 2       1 4  4barswillflash           Will flash in turns     Constant ED LE ht bar will be on and the  2   2 083V cell               Current other three bars will flash in turns    mode The two right bars will be on and    2 083   2 167V cell the other two bars will flash in  turns     Voltage       PAM  gt  2 167 V cell The three right bars will be on and  the left bar will flash    Floating Batteries are fully  4 bars will be on    mode charged     4 3 Reference Code             coe          MN    Constant         06     Battery temperature is too low  Battery temperature is too high  PV is low loss  UC Output derating caused from high PV voltage  arning  Output derating caused from high temperature  Low alarm for battery temperature       5  CHARGING LOGIC    5 1 3 stage Charging   In general  this solar charge controller is designed with 3 stage battery charging  algorithm for fast  efficient  and safe battery charging  The following picture shows the  sequence of charging stages           1  Bulk charge stage   In bulk charge stage  charge current begins to flow  typically at the maximum rate of  the charge source  The controller will supply solar pow
5.   charging current  of Equalization       mmm    17    If solar charge controller is working in float stage  but at this time       setting  equalization interval  battery equalization cycle  is arrived  it will transfer to  equalize stage     Equalize Voltage    Float Voltage          Equalize charging time and timeout   In Equalize stage  based on maximum charging current of battery equalization  the  controller will supply solar power to charge battery as much as possible until battery  voltage raises to battery equalization voltage  Then  constant voltage regulation is  applied to maintain battery voltage at the battery equalization voltage    The battery will remain in the Equalize stage until setting battery equalized time is  arrived     Equalize    Equalize Voltage  Absorption Voltage    Float Voltage   EQUALIZE       However  in Equalize stage  when battery equalized time is expired and battery voltage  doesn t rise to battery equalization voltage point  the solar charge controller will  extend the battery equalized time until battery voltage achieves battery equalization  voltage  If battery voltage is still lower than battery equalization voltage when battery  equalized timeout setting is over  the solar charge control will stop equalization and  transfer to float stage     18         Equalize Charging  Timeout    Equalize Voltage                   Absorption Voltage    Float Voltage  EQU ALIZE       5 3 Setting Parameter and Default Value  Recommended and default 
6.  Recommended wire size     Typical Amperage   Wire Type 75 C Wire 90 C Wire         4 AWG  25 mm     6 AWG  16 mm    2 AWG  35 mm     4 AWG  25 mm      Overcurrent Protection and Disconnects   CAUTION  Circuit breakers or fuses must be installed in both battery and solar  Circuits    The battery circuit breaker or fuse must be rated to 125  of the maximum current or  more  The recommended breaker fuse rating for use with the charger is listed in the  below table    Recommended breaker rating     Minimum battery circuit breaker fuse rating    1 25 x 60 Amps   75 0 Amps    A disconnect is required for the battery and solar circuits to provide a means for       removing power from the charger  Double pole switches or breakers are convenient for    disconnecting both solar and battery conductors simultaneously     Connect the Power Wires  WARNING  Shock Hazard    The solar modules can produce open circuit voltages in excess of 100 Vdc when in    sunlight  Verify if solar input breaker or disconnect has been opened  disconnected     before connecting system wires        Battery    Solar   Solar      Battery     common negative     Connect terminals by following below steps  Refer to diagram above             Make sure that      system input and output disconnect switches are both turned  off before connecting power wires to the charger  There are no disconnecting  switches inside the charger    Make 4 power wires first  Remove insulation sleeve 10 5mm and the conductor  should be 
7.  earth ground   The grounding terminal is identified by the ground symbol shown below that is    stamped into the wiring box just below the terminal        The minimum size of the copper grounding wire is 8 AWG  10 mm2    WARNING  Risk of Fire    DO NOT bond system electrical negative to earth ground at the controller     3 6 Remote Temperature Sensor   The included Remote Temperature Sensor  RTS  is recommended for effective  temperature compensated charging  Connect the RTS to the 2 pole terminal  see  figure as below   The RTS is supplied with 33 ft  10 m  of 22 AWG  0 34 mm2  cable     There is no polarity  so either wire    or    can be connected to either screw terminal     7    The RTS cable may be pulled through conduit along with the power wires  Tighten       connector screws with 5 in Ib  0 56 Nm  torque   NOTE  The RTS is optional package  Please check local dealer for the details        CAUTION  The controller will not activate temperature compensate charging function  if the RTS Is not used    CAUTION  Equipment Damage   Never place the temperature sensor inside a battery cell  Both the RTS and the battery  Wil  be darnaged    NOTE  The RTS cable may be shortened if the full length is not needed     3 7 Battery Voltage Sense   The voltage at the battery connection on the controller may differ slightly from the  voltage directly at the battery bank terminals due to connection and cable resistance   The Battery Voltage Sense connection enables the controller to me
8.  please follow required spec to select  appropriate cable size  It s very important to correctly operate this charger    Be very cautious when working with metal tools on or around batteries  A  potential risk exists to drop a tool to spark or short circuit batteries or other  electrical parts and could cause an explosion    Please strictly follow installation procedure when you want to disconnect PV or  battery terminals  Please refer to INSTALLATION section of this manual for the  details    GROUNDING INSTRUCTIONS  This charger should be connected to a  permanent grounded wiring system  Be sure to comply with local requirements  and regulation to install this charger     NEVER cause short circuited on battery output     11  Warning   Only qualified service persons are able to service this device  If    errors still persist after following troubleshooting table  please send this    charger back to local dealer or service center for maintenance     2 INTRODUCTION    Thank you for selecting this solar charge controller  This solar charge controller is an  advanced solar charger with maximum power point tracking  Applying intelligent MPPT  algorithm  it allows solar charge controller to extract maximum power from solar    arrays by finding the maximum power point of the array     The MPPT battery charging process has been optimized for long battery life and  improved system performance  Self diagnostics and electronic error protections  prevent damage when installation errors o
9. D x 1    3 2 Preparation    Before connecting all wirings  please take off wiring box cover by removing screws as    shown below        3 3 Mounting the Unit  Consider the following points before selecting where to install     This solar charge controller is designed in IP31 for indoor applications only    Do not mount the unit on flammable construction materials    Mount on a solid surface   Install this charger at eye level in order to allow the LCD display to be read at all  times    For proper air circulation to dissipate heat  allow a  clearance of approx  20 cm to the side and approx  50 cm  above and below the unit    The ambient temperature should be between 0  C and 55  C  to ensure optimal operation    The recommended installation position is to be adhered to  the wall vertically              Install the unit to      wall by screwing four screws     Refer to right chart     2              2     2            2     2     2       A  4    3 4 Power Connection  Wire size  The four large power terminals are sized for 14   2 AWG  2 5   35    mm   wire  The terminals are rated for copper and aluminum       conductors  Use UL listed Class B 300 Volt stranded wire only  Good  system design generally requires large conductor wires for solar module and battery    connections that limit voltage drop losses to 2  or less     Minimum Wire Size  The table below provides the recommended minimum wire size allowed for the charger   Wire types rated for 75     and 90     are listed    
10. SPECIFICATIONS    Table 1 Electrical Specifications    MODEL MPPT 3KW  Nominal System Voltage 12  24  or 48 VDC  Auto detection   Maximum Battery Current 60 Amps    Maximum Solar Input  145V  Voltage  PV Array MPPT Voltage  60 115VDC  Range    12 Volt  800 Watts  Maximum Input Power 24 Volt  1600 Watts  48 Volt  3200 Watts    7    0  60  0    5    PV Array voltage  amp  Battery    current    3    Battery Current  Amps   A  eo    0  20  10    0  110 115 120 125 130 135 140 145 150    Array Voltage  Volts     70  60    50    Heatsink temperature  amp       Battery current T    Battery Current  Amps     20  10   0  60 65 70 75 80 85 90 955    Heatsink Temperature   degrees C     Transient Surge Protection 4500 Watts   port       21       Solar high voltage disconnect  Solar high voltage reconnect    Battery high voltage disconnect  Protections    Battery high voltage                     High temperature disconnect  High temperature reconnect    Table 2 Battery Charging    MODEL MPPT 3K  Charging Algorithm 3 Step  Charging stages Bulk  Absorption  Float    Temperature  compensation  5 mV          cell  25   C ref      coefficient  Temperature    0   C to  50   C  compensation range  Temperature      Absorption  Float  compensated set points    Charging Set points Absorption Stage Float Stage  Flooded Battery 14 6V   29 2V   58 4V 13 5V   27V   54V    AGM Gel Battery  14 1V   28 2V   56 4V 13 5V   27V   54V   Default     Over charging voltage 15V   30V   60V    Over charging  14 5
11. V   29V   58V  comeback voltage    Battery defect voltage 8 5V   17V   34V    Battery defect  9V   18V   36V  comeback voltage       22          Battery Voltage  per cell Charging Current  96    Voltage  Charging Curve    10  TO  mini ins  imu 3  Bulk Absorption   Constant Current   Constant Voltage     Table 3 Mechanical and Environment    Charger MODEL MPPT 3K    Product size  W x H x D   315 x 165 x 128    pee Ta    Ambient Temperature  0     to 55  C  Range    Storage Temperature  40  C to 75  C    Humidity 0  90  RH No condensing        23    
12. asure the battery  terminal voltage precisely with small gauge wires that carry very little current  and thus  have no voltage drop  Both battery voltage sense wires are connected to the 2 pole    terminal inside of wiring box  see figure as below      Be careful to connect the battery positive     terminal to the voltage sense positive      terminal and battery negative     terminal to the voltage sense negative terminal       No damage will occur if the polarity is reversed  but the controller cannot read a    reversed sense voltage        A battery voltage sense connection is not essential required to operate your controller   but it is recommended for best performance  The battery voltage sense will ensure    that the voltage display in LCD is very accurate     The voltage sense wires should be cut to length as required to connect the battery to  the voltage sense terminal  The wire size can range from 16 to 24 AWG  1 0 to 0 25  mm2   A twisted pair cable is recommended but not required  Use UL rated 300 Volt  conductors  The voltage sense wires may be pulled through conduit with the power    conductors  Tighten the connector screws with 5 in lb  0 56 Nm  torque     The maximum length allowed for each battery voltage sense wire is 98 ft  30 m      3 8 Communication Connections  The default communication of the controller is RS232 port  You can use supplied cable  to connect RS 232 port of the controller to PC  It can be used for monitoring or    upgrade the firmware in sh
13. er to charge battery as much as  possible     2  Absorption stage   When battery charging voltage is reached to Absorption voltage point  the charging  stage changes from bulk charge to Absorption  Constant voltage regulation is used to  maintain battery voltage at the Absorption stage    If the charging current drops to one tenth of the maximum charging current setting  point  the charging status will change to Float stage     ABSORPTION  Voltage    Current       If the elapsed time of absorption stage is over setting value for C V charging time  it  will also transfer to Float stage     Absorption  Voltage       3  Float Stage  After the battery is fully charged in the Absorption stage  the controller will reduces the  battery voltage to the setting point of Float voltage   Once in Float stage  constant voltage regulation is used to maintain battery voltage at  setting point of float voltage   e Float timeout  If the battery voltage remains lower than the Float voltage for 30 minutes  the  controller will return to Bulk charging stage         ABSORPTION    15    e Float cancel voltage  Once the battery voltage drops to setting point of Float cancel voltage  the  controller also returns to Bulk charging stage   Float cancel voltage   Floating charging voltage      1V x battery numbers in series          Float Voltage                                         L    R          et ee                           Float Cancel    Voltage ABSORPTION       5 2 Equalize Stage    Equalizat
14. ion function is added into solar charge controller  It reverses the buildup of  negative chemical effects like stratification  a condition where acid concentration is  greater at the bottom of the battery than at the top  Equalization also helps to remove  sulfate crystals that might have built up on the plates  If left unchecked  this condition   called sulfation  will reduce the overall capacity of the battery  Therefore  it s  recommended to equalize battery periodically        16       How to Apply Equalization Function  You must enable battery equalization function in monitoring software first        Battery type     pply Rated battery voltage  Auto    Battery absorption charging voltage     pply BTS temperature compensation ratio   Battery Floating charging voltage     ply Battery C V  charge time     Max  charging current     Battery equalization  Enable   Disable           Battery equalized time  din  990 Battery equalized timeout     The max current of battery equalization  A Apply Battery equalization voltage     Equalization interval  Apply ssing key for 3 second        Then  you may apply this function in device by either one of following methods   1  Setting equalization interval     1           2  Or  press the button for 3 seconds until LCD shows  C 1        e When to Equalize  In Absorption stage  if the charging current drops lower than the maximum  charging current of battery equalization  the controller will start to enter Equalize  stage            The Max
15. ort distance     Intelligent slot allows the controller to use different communication methods except  RS232  Slot can support SNMP  USB  MODBUS cards and so on     You can follow the below figure to install the card if you had purchased for it           Insert bundled software CD into a computer and follow on screen instruction to install  the monitoring software  For the detailed software operation  please check user    manual of software inside of CD     10    4                      4 1 Power Up    WARNING  Risk of Damage    Connecting the solar module to the battery connector will permanently damage the  controller     e Confirm that the solar and battery polarities are correctly connected to the  controller       A battery must be connected to the controller before operating it  The controller  will not operate only with solar input  Solar input can trigger the controller to start  up when the battery is connected without pressing the button    e Turn on battery disconnect switch first  And press operation button for a while   Then  it will indicate a successful start up in LCD display    e Turn on solar disconnect switch  If the solar module is in full sunlight  the    controller will begin charging     4 2 Operation and Display Panel  The operation and display panel  shown in below chart  is on the front panel of the  controller  It includes three indicators  one operation button and a LCD display     indicating the operating status and input output power information  
16. parameter settings are listed below     Parameter Battery  Absorp    Float  Equalize  Equlize   Absorp    Equalize   Equalize   Equalize  pe Em E ERN EE pum Time pem n    vot              En Disable  Minutes  Minutes   Minutes   Dass                       ome  we                  19    6  TROUBLE SHOOTING    Situation  Fault Fault Event Solution  Code    1  Restart the charger   01 Over charge current   2  If the problem remains  please contact your  installer   1  Keep      charger      the cool environment   Over temperature 2  If the problem remains  please contact your  installer   1  Check the battery wire connection   Battery voltage under   2  If the wire connection is ok  please contact your  installer   1  Reconnect the battery to the charger   Battery voltage high   2  If the problem remains  please contact your  installer     4  1  Please check the voltage of the solar panel  it  05 PV high loss should be less than 140V   2  If the voltage is ok  please contact your installer   1    Check your remote temperature sensor and  Battery temperature your battery ambient temperature   too low 2  If the problem remains  please contact your  installer   1  Check your remote temperature sensor and  Battery temperature your battery ambient temperature   too high 2  If the problem remains  please contact your  installer   1  Check battery wire connection   No display in LCD screen  2  Push the button  if the problem remains  please  contact your installer     0       20    7  
17. plated Tin  Refer to the chart below     10 5mm            Pull all wires into the wiring box  The Remote Temperature Sensor and Battery    Tin Plating    Sense wires can be inside the conduit with the power conductors  It is easier to pull    RTS and Sense wires before the power cables     WARNING  Risk of Damage    Be sure that the battery connection is made with correct polarity  Turn on the battery    breaker disconnect and measure the voltage on the open battery wires BEFORE    connecting to the controller  Disconnect the battery breaker disconnect before wiring    to the controller     4  Connect positive terminal     of battery to the battery positive terminal     on the  controller   5  Connect negative terminal     of battery to one of the Common Negative terminals        on the controller     WARNING  Risk of Damage  Be sure that solar connection is made with correct polarity  Turn on the solar  breaker disconnect and measure the voltage on the open wires BEFORE connecting to the    controller  Disconnect solar breaker disconnect before wiring to the controller     6  Connect positive wire     of solar module to the solar positive terminal     on the  controller    7  Connect negative wire     of solar module to one of the Common Negative terminals      on the controller    8  Screw four  4  power terminals tightly with 50 in lbs torque   5 65 Nm     3 5 Grounding and Ground Fault Interruption  Use a copper wire to connect the grounding terminal in the wiring box to
18. r system faults occur  This charger also  features multifunctional LCD with communication ports for remote battery    temperature and voltage measurement     2 1 Features   eIntelligent Maximum Power Point Tracking technology increases efficiency 25  30   eCompatible for PV systems in 12V  24V or 48V   eThree stage charging optimizes battery performance   eMaximum charging current up to 60A   eMaximum efficiency up to 98    eBattery temperature sensor  BTS  automatically provides temperature compensation  eAutomatic battery voltage detection   eSupport wide range of lead acid batteries including wet  AGM and gel batteries  eIntegrated intelligent slot compatible with SNMP MODBUS communication    2 2 Product Overview    POWER ON FAULT WIRING FAULT    CHARGING WARNING          LCD display   Power On Charging indicator  Fault and warning indicator  Wiring fault indicator  Operation button   PV connectors   Battery connectors    Remote temperature sensor terminal    Se           e            Battery voltage sense terminal    NN  C      Wiring box cover    E  E      Communication port      a  N      Intelligent slot    FN  CJ      Grounding terminal    3  INSTALLATION    3 1 Unpacking and Inspection  Before installation  please inspect the unit  Be sure that nothing inside the package is  damaged  You should have received the following items inside of package     e Solar charge controller x 1  e User manual x 1   e Communication cable x 1  e Battery Voltage Sense x 1  e Software C
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
取扱説明書 - ブリッツ  TECNICA 315 - kleer  Manuale d`uso per l`utente  SMART Board 400 series interactive display overlay user`s guide  KIT CUILLÈRE POUR GRENADE TORNADO AI  Documento de ayuda    PILOT WA XV _W-Betriebsanleitung.indd  GWS Professional - Ferramentas Bosch  Sony VAIO SVE1712ACX    Copyright © All rights reserved. 