1. 2c Display Controller User Manual DATAPATH Version 01 03 01 DATAPATH EXCELLENCE BY DESIGN Contents Safety Instructions Introduction Configuration Examples Unpacking Description Setting up the x4 Configuring the x4 Operating Instructions x4 Control Application Specification Datapath Limited Index UK Headquarters and Main Sales Office 10 13 14 16 17 26 27 28 30 Safety Instructions To prevent damage to your Datapath product or injury to personnel operating the equipment please read the following safety precautions prior to operation These instructions should be made available to all those who will use and operate Datapath products Power Supply All Datapath products require a mains power supply This power supply must be disconnected when equipment is being upgraded or relocated Only the power supply unit provided should be used x4 only Cables Do not expose cables to any liquids doing so may cause a short circuit which could damage the equipment Do not place heavy objects on top of any cables as this can cause damage and possibly lead to exposed live wires Ventilation All computer equipment should be located in a well ventilated area All ventilation holes on the unit casing must be kept clear of any obstruction at all times Failure to do so will result in the system over heating and damaging your equipment Working Environment The equipment should be locate
2. Each output of the x4 can select a different region of the input source image This dialog Fig 11 displays the settings of each region region 1 corresponds to output 1 etc The numbers denote the top left width and height coordinates of the region that is to be displayed Note that these are de scribed in terms of the current active input resolution If the input resolution changes the capture region coordinates scale to the new input resolution in order to maintain the same proportions Input Capture Regions Region 1 Region 2 0 x 0 960 x 540 960 x 0 960 x 540 No Rotation No Rotation Region 3 Region 4 0x 540 960 x 540 960 x 540 960 x 540 No Rotation No Rotation Fig 11 To modify any of these settings click on Modify to display the edit dialog Fig 12 x4 nput Capture Regions Current Input Input EDID Preferred Mode 1920 x 1080 59 939Hz 1920 x 1080 59 933Hz Predefined Regions Scaling Optimisation Otet Odeo Region 1 Region 2 Top 0 i Top 0 E X E ELE Left 0 Left 950 4 Region 3 Region 4 Rotated 180 Top 540 width 960 Left 960 4 Height 549 4 Transform No Rotation v 22 Predefined Regions For ease of use there are preset buttons to select the two most popular configurations Quarter or Replicate Quarter The first monitor displays the top left hand corner of the input image the second monitor the top
3. 0 1332 290667 Email sales datapath co uk www datapath co uk REF BREE HARHA 1 TIE mR HE 2006 2 28 Ba eas ee a PRE TEP a mre eu m ee NER i ARRESE hee EAE EE E A Ae TEHE A WP ERUNT iE PRLS AR xm T IB FARTS ASHE rates This symbol mari is for Chins only 2 AAE 6 RHEE AAE SHR FPR e HH Gee AAM SAT Re Ph Ph a i eae SE RAE 1 Toxic ar Hazardous Substanpbes and Elements er Geko kn hcl aoe cd D pa TO Ai SARE Fa Re Ag Od COr VTHI PBB IPBDE x o oy ot o jo Contents Sine ind iE Ox PT D ETERS ae ee aT Se Be SE ST 112 06 EEL BR AR AR SE ERTA F9EE EH RARA SVTS ERLE EE 1 Ferree ER GRR 3 fa Bie GB18455 2001 Ks uHHEL TTA eT ee PRI ee a HRS ar ee RASS LOPE 30
4. Output displayed across all four screens Fig 3 13 Configuring the x4 Factory Default Settings The x4 stores a number of parameters to configure its operation This allows it to operate stand alone in a very flexible manner The configurations affect the input and output display modes as well as the required partitioning of the input image between monitors By default the x4 is configured as follows Input EDID Preferred Mode 1920 x 1080 x 60Hz SMPTE timings Output monitor mode Use Monitor Preferred Mode Default 1920 x 1080 x 60Hz SMPTE Cropping Mode 2X2 equal split 960x540 No Rotation The default settings are changed using the Windows application provided which can be run on any Windows platform and connected to the x4 via the supplied USB cable A description of the use of the application is provided in the x4 Control Application section A Command Line Interface utility is also available for Mac OS x 10 6 The sections below describe the settings that are possible and why they may be needed For details on how to program the x4 hardware with your desired configurations please see the x4 Control Application section Configuring DVI Input resolution Because the timings and resolution of the DVI input are set by the DVI source machine the x4 can only configure this indirectly by presenting a programmable Preferred Mode as part of its EDID Extended Display Identification Data Most graphics cards
5. and HDMI appliances automatically select the Preferred Mode resolution and timings presented by the x4 EDID but they may need to be forced to re detect if the EDID contents are changed by the x4 application This would typically be via a hot plug event caused by disconnecting and reconnecting the DVI input cable The configuration application will allow read back of the resolution that is currently being detected as well as the ability to read and write the internal EDID rom Monitor Outputs The x4 can be configured to read the corresponding EDID of each monitor that is connected and to drive out a signal that corresponds to the resolution timings and mode RGB or DVI of the Preferred Mode This is the factory default configuration Please note that when different monitors are attached to the four outputs each may advertise a different Preferred Mode therefore each output will be driven at a different mode 14 Whenever the monitor EDID is used the x4 will calculate the internal scale factors to ensure that the monitor at whatever resolution it is being driven will still display the correct proportion of the input im age If an EDID cannot be read for example if the monitor cable does not support the DDC signals required there is a default mode that can be programmed into the x4 s memory This is factory configured to 1080p In some cases it may be that the user requires a very specific output timing for example when frame l
6. not need to be related to that of the input as the Datapath x4 will optionally upscale and frame rate convert each cropped region indepen dently However if the Datapath x4 detects that frame rates identically match it will automatically frame lock all outputs and if possible frame lock these to the input signal Additionally each output can be independently mirrored or rotated through 90 180 or 270 to support creative mixes of land scape and portrait monitors The Datapath x4 is also ideal for use with edge blending projectors supporting image overlapping Configuration Examples Listed on the next few pages are just a few examples of what can be achieved with the Datapath x4 The list of examples is not definitive and users are encouraged to experiment with different display configurations Duplicate the input signal x 4 and displays each duplicate on separate screens 30 Frames per Second 3840 x 2150 60 Frames per Second 1080p eee Amm 60 Frames per Second 60 Frames per Second 1080p 1080p Divide the input signal into quadrants and display each quarter on separate displays with optional frame rate conversion in this case 30Hz to 60Hz Crop regions can be adjusted to provide monitor bezel compensation Landscape 3x 16 9 Portrait Duplicate the input signal x2 and display 1 on a single landscape display and divide the 2nd into thirds rotate to portrait upscale and split between 3 displays
7. video based select Video Scaling optimisation will ensure a smooth un pixellated display of video All modifications to the Region settings can be saved as part of a vqs file removing the requirement to input the same settings again To save the settings select the Save command in the File menu To open a saved vqs file select the Open command Monitor Outputs The Monitor Outputs group shows the actual resolution and refresh rate that each of the four x4 outputs is currently providing To see more information such as whether this is an analog RGB or DVI mode if it is the monitor EDID preferred mode or a default mode programmed into the x4 along with detailed timing information click on the Modify button for the required output The frame lock status is indicated by the small coloured squares Green The outputs are frame locked to the Vsync of the first monitor using a common reference clock If the Input frame lock light is green see above then the reference clock is taken from the input DVI source and the system is fully frame locked to this source If the input frame locked indicator is grey then the outputs are frame locked together but are not related to the input sync 23 Grey The outputs are NOT frame locked Monitor Outputs DVI I Out 1 m 1920 x 1080 59 934Hz DVI I Out 3 Mj 1920 x 1080 59 934Hz DVI I Out 2 BS 1920 x 1080 59 934Hz DVI I Out 4 E 1920 x 1080 59 934Hz Fig 13 Individua
8. 1x1920x1080 4x 1280x1024 Crop input signal upscale specific areas and display on 4 separate screens 7 Crop the input signal into x4 and display x2 quarters landscape and x2 quarters portrait Crop the input signal x4 rotate through 909 180 or 2709 display in landscape and portrait Arbitrary crop regions can allow the monitors to be artistically arranged but maintain an undistorted image Unpacking Your packing box should contain the following items e The x4 or x4 1U Display Wall Controller e The x4 PSU Power supply unit with international blades Only the power supply unit provided should be used x4 only e ixMains power cable x4 1U only e USB 2 0 cable Type A to Type B e Datapath CD containing Configuration Application and User Manual Note We recommend that you do not discard the packing box until you are completely satisfied with the x4 and it is fully installed and working correctly We also recommend that you make note of the serial number of the controller in a prominent place before you connect it to the computer This should hasten any query should you need to contact our Technical Support De partment The serial number is displayed on the x4 and the box label Fitting the x4 PSU Blades European Blade Release Catch USA Blade Select the appropriate blade for use place the top edge of the blade into the recess of the PSU and then slide upwards ensuring the release catch cl
9. PC to connect to the x4 box and for the user to program its configuration Once configured the x4 will run stand alone without the need for the USB connection and will auto detect input resolutions and adjust internal scaling to drive the output monitors consistently Frame lock The Firmware running on the x4 will detect when input and or output timings are set to identical frame rates and will automatically frame lock the syncs in these cases In all frame lock modes the timings are configured to share a common reference clock so there will be no drift in synchronisation and therefore no requirement for continual adjustment that can sometimes upset LCD panels The frame lock status is shown in the x4 Control Application 16 x4 Control Application Application Installation Note Do not plug the x4 into a USB port until the driver installation is complete Locate the Install folder on the Datapath CD supplied with the x4 run install exe and follow the installation wizard During installation a warning message is displayed stating that the driver does not have Windows Logo accreditation Select Continue Anyway to complete the installation The Datapath x4 can now be connected to a suitable USB 1 0 or 2 0 port using the cable supplied At this point the hardware will be detected by Windows as a USB API and a New Hardware wizard is displayed Allow the wizard to search and click on the recommended option to enable the previously inst
10. U Cooling The unit contains a cooling fan The input and output vents should not be restricted Full speed 12Mbits s operation supported To 330 Mpixels s Output Screens Resolutions Up to 2 5Mpixel maximum 2048 pixels in either direction Arbitrary Up Scaling Up to 64 x Non integer scale factors allowed Firmware Support Updates supported via USB 3 years Models Available Desktop Display Wall Controller Rack Mountable Display Wall Controller 26 Datapath Limited Datapath has a long and very successful history in the computer graphics industry Datapath has been designing and supplying high performance high quality graphics display systems to the world s larg est and most demanding companies and institutions since 1982 Datapath was one of the founding companies of multi screen Windows acceleration using single and multi board solutions Now using the very latest display technology Datapath offers some of the world s leading multi screen graphics accelerators for the most demanding applications As new technology advances so we at Datapath improve the performance and functionality of both our hardware and software to give our customers more Following a continuous development pro gram we pride ourselves on our support and responsive nature towards all our customers and their changing needs As more sophisticated equipment and techniques become readily available so we are there to exploit the power and potential that t
11. Use the slider to compensate for the loss signal quality due to DVI cable lengths over 5 m The equaliza tion hardware can compensate for cables up to 20m in length To change the timings of the input EDID click on the Modify button and the following dialog is displayed Fig 9 19 Current 1920 x 1080 59 939Hz Copy Timings Input Edid Preferred Mode Timing Standard CVT Reduced Blanking z i Display Mode Horizontal Pixels 1920 Vertical Lines 1080 Vertical Refresh 60 000 Scan Type Progressive Pixel Clock 138 500 Format DVI Detailed Timings Display as Video Definition Y Horizontal Timings Vertical Timings Sync Width 32 Sync Width 5 Back Porch 80 Back Porch 23 Front Porch 48 Front Porch 4 Polarity Positive Polarity Negative Total Pixels 2080 Total Pixels 1111 Actual Refresh 66 586 KHz Actual Refresh 59 933Hz Lo cw J Fig 9 The DVI D Input dialog displays the resolution of the current mode for reference and allows the timings of the EDID preferred mode to be edited To populate the EDID timings with the current timings click on the Copy Timings button The dialog supports standard timing formulae such as e VESACVT e VESA CVT Reduced Blanking e SMPTE for HD modes e VESAGTF e Custom Selecting Auto from the drop down list will typically default to the VESA CVT algorithm which best matches typical standard VESA output modes However to minimise dot clocks and hence
12. al Link DVI Single Link DVI and also HDMI not HDCP compliant by using the optional DVI HDMI Adapter DVI I Output Sockets The four DVI I Out sockets are used to connect the x4 to the output monitors The x4 supports both DVI and analog RGB monitors Power The Power socket is where the power source is connected to the x4 The x4 PSU supplied is plugged into the Power socket The power LED on the front of the x4 illuminates when a power supply is connected 12 Setting up the x4 e Ensure the power supply for the DVI source is disconnected e Connect the cable from the DVI source to the input socket on the rear of the x4 e Connect the four displays to the output sockets on the rear panel of the x4 e Connect the x4 PSU to the x4 and switch on the power supply at the mains socket using the correct international blade see page 9 e Power up the DVI source The Power LED located on the front panel will illuminate to indicate that power has successfully been applied to the unit The x4 incorporates an internal processor that will continuously monitor the received DVI signal and whenever a valid and stable input is detected the Input LED is illuminated If the Input LED is not illuminated the x4 cannot detect a valid DVI input source During operation the x4 is able to adjust its internal operation to maintain the programmed output pro portions even when the input resolution changes Input source Output 2 DVI Source
13. alled driver to be associated with the new hardware Press Continue Anyway to accept the driver Running the x4 Control Application To open the x4 Control application select Start All Programs Datapath x4 The application will search for an x4 connected to your computer and display the status of the first x4 detected Should there be more than one x4 in use a list of all available x4 s can be found in the File menu Once the application has detected an x4 the main status screen is displayed Fig 4 e quie ER aera DATAPATH o ia Excel DVI I OUT 2 DVI D INPUT DVI I OUT 4 Power DVI D Input Device Current EDID Preferred Mode USB Name 2 7061973f000000 E 1920 x 1080 59 939Hz 1920 x 1080 59 933Hz 7 DualLink Friendly Name 2 7061973f000000 Input Capture Regions Monitor Outputs Region 1 DVI I Out 1 DVI I Out 2 0x 0 960 x 540 E 1920 x 1080 59 934Hz B 1920 x 1080 59 934Hz moat DVI I Out 3 DVI I Out 4 BS 1920 x 1080 59 934Hz B 1920 x 1080 59 934Hz Modify HW Rev 0x01 FWRev0x0207 Flash Rev 0x12 App Ver V2 0 5 17 The main control dialog is divided into the following groups Connection Diagram DVI D Input Input Capture Regions Device Monitor Outputs Connection Diagram The connection diagram displays a schematic view of the rear panel of the x4 to assist in identifying the connectors DVI I OUT 1 Occ DVI I OUT 3 P aa T EESENENN ENEENEEN Out 7 HHAH ar q
14. d in an environment free from dust moisture and extreme changes in temperature and should be placed on a stable and solid work surface Liquids hot cold drinks etc should not be placed near the equipment as spillage could cause serious damage Gas Flammable Liquids Electronic equipment should never be used in the presence of gas or any flammable liquid doing so could result in an explosion or serious fire Smoke Unusual Smells Should you notice smoke or unusual smells being emitted from your computer turn off and unplug the system from the mains supply The system should then be passed to a qualified technician for inspection Continued operation could result in personal injury and damage to property Maintenance Maintenance should only be carried out by competent technicians any Datapath products that are physically damaged should be returned to Datapath for repair using Datapath RMA procedures Disposal At the end of life all Datapath products should be disposed of as per local laws and regulations dictate In UK contact Datapath to arrange disposal Our WEE registration number is WEEE AA0005ZR Introduction The Datapath x4 is a stand alone display wall controller that accepts a standard single or dual link DVI input and can flexibly display this across four output monitors Each output can be driven as DVI or analog RGB and can represent an arbitrary crop region of the original input image The output resolution and frame rate does
15. dialog is displayed Fig 14 Activate the Test pattern generator by sececting On and use the drop down menu to select the required test pattern see Fig 14 Note The test pattern functionality is only available on software release Version 2 0 12 onwards Detailed information on upgrading your x4 can be found in the latest x4 software download available on the Datapath website The rest of the dialog is identical to that for setting the Input timings with the exception that for the out put monitors it is possible to select Analog RGB VGA output as well as DVI All modifications to the Output settings can be save as part of a vqs file removing the requirement to input the same settings again To save the settings select the Save command in the File menu To open a saved vqs file select the Open command Finally there is a Test button which should be used when defining a default mode that you are not sure the attached monitor can support In test mode the output timings are programmed but they are not saved to non volatile memory on the x4 until the OK button is pressed to accept the mode 25 Specification Physical Dimensions X4 235 X 175 X 4 mm 9 25 x 6 9 x 1 75 DESERUIT E 438 X 173 X 40mm 17 24 x 6 81 x 1 57 Operating Temperature Range Temperature Range 0 35 lo 35DegC 33 96DegF 96 DegF Power Requirements 5V DC 18W Universal mains power adapter supplied 100 240V Datapath x4 1U Internal PS
16. his technology presents Technical Support Registered Users can access our technical support line using email and the Support page on the Data path Web Site usually with a response within 24 hours excluding weekends Via Email Send an email to support datapath co uk with as much information about your system as possible To enable a swift response we need to know the following details Specification of the PC including processor speed e Operating System e Application Software e Datapath Hardware Software e The exact nature of the problem and please be as specific as possible Please quote version and revision numbers of hardware and software in use wherever possible Copyright Statement Datapath Ltd England 2011 Datapath Limited claims copyright on this documentation No part of this documentation may be reproduced released disclosed stored in any electronic format or used in whole or in part for any purpose other than stated herein without the express permission of Datapath Limited Whilst every effort is made to ensure that the information contained in this User Manual is correct Datapath Limited make no representations or warranties with respect to the contents thereof and do not accept liability for any errors or omissions Datapath reserves the right to change specification without prior notice and cannot assume responsibility for the use made of the information supplied All registered trademarks used w
17. icks firmly into place and secures the blade inside the recess To remove the blade press the release catch down fully and pull the blade away from the PSU recess The PSU is shipped fitted with the UK blade Description Front panel DATAPATH SK L POWER INPUT STATUS EXCELLENCE BY DESIGN Fig 1 Operation Indicators The front panel has three LEDs to indicate the operational status of the x4 e Power e Input e Status Power e When illuminated the Power LED indicates the x4 is connected to a mains supply using the supplied PSU Input e When illuminated the Input LED indicates a valid DVI source is connected Status e Continuous illumination Indicates the x4 is operating normally e Flashing Unit is operating over the normal operating temperature Ensure the input fan vent is not blocked e Ifthe Status LED goes off and remains off this indicates that the settings configured in the x4 application no longer match the input this is normally the result of a change of input The x4 will compensate for the settings and reconfigure itself to display as near to the settings as possible The output will still be displayed but not necessarily as expected When the x4 device is connected to a PC by a USB cable and the x4 Control application is active then all three lights flash in turn to help to identify which unit is being controlled 10 Output Framelock x4 1U only The Output Framelock is intended
18. ithin this documentation are acknowledged by Datapath Limited 27 Index A Application Installation 17 arbitrary crop 4 B bezel compensation 6 C cables up to 20m 19 configuration 14 Configuring the x4 16 Connecting the x4 13 connection diagram 18 Cooling 26 Copyright Statement 27 Crop regions 6 D Default Settings 14 device name 18 display orientations 5 Dual Link DVI 12 DVI D Input 19 E edge blending 4 EDID Preferred Mode 14 edit dialog 22 equalization 19 F Firmware Support 26 H Hardware wizard 17 HDMI 12 Input LED 10 Input socket 12 Input Surface 26 L LED s 10 Limitations 21 M MacOS 14 mirrored 4 Models Available 26 Modify button 23 24 Monitor Outputs 23 O onboard micro 11 Operation Indicators 10 Output Framelock 11 Out sockets 12 P Physical Dimensions 26 Power LED 10 Power Requirements 26 Power socket 12 28 Power Supply 3 PSU Blades 9 Q Quarter 23 R Rear Panel 11 regions to be displayed 15 Replicate 23 rotate to portrait 7 S safety precautions 3 Scaling Optimisation 23 Single Link DVI 12 Status 10 Status LED 10 Sync sockets 11 T Technical Support 27 Test button 25 test patterns 25 U UK Headquarters 28 upgrading your x4 25 Up Scaling 26 USB socket 11 W Warranty 26 Windows 17 Windows 7 20 29 UK Headquarters and Main Sales Office Datapath Ltd Alfreton Road Derby DE21 4AD UK Tel 44 0 1332 294441 Fax 44
19. l monitor outputs can be configured by clicking on the corresponding Modify button This will bring up a timing dialog similar to that of the input timings This dialog is shown in Fig 14 Source of Mode Use the Monitors Preferred mode Always use the Default mode Preferred Mode Copy Preferred Mode Copy Output 1 Default 1920 x 1080 60 000Hz Test pattern generator off Default Timings Timing Standard reme Greyscale Colourbars Moving greyscale Moving colourbars C NN Horizontal Pixels 1920 Vertical Refresh 60 000 Hz Pixel Clock 9 wa 148 500 Detailed Timings Display as Horizontal Timings Sync Width Back Porch Front Porch Scan Type Vertical Lines 1080 Progressive v Format The source of mode selection controls whether the x4 output should take its timing values and resolution from the preferred mode of the monitor that is connected or use its internally programmed default mode Please note that only the internal default timings can be edited in this dialog If Use the Monitors Preferred Mode is selected but no valid EDID can be read from the attached monitor then the x4 firmware will program the output using the default mode timings The x4 application has built in test patterns to enable the user to view a display on screen without a source connected to the x4 To display the test pattern click the Modify button on the required output and the modify output
20. lication In order to support portrait orientation of monitors the source data can be rotated by 90 180 or 270 as itis output to the monitor 15 Operating Instructions DVI Input When the X4 is powered up successfully and the Power Input and Status LED indicators are illuminated this indicates that a DVI input mode has been detected and is working normally If the Input LED indicator is not on check to ensure a single or dual link DVI cable is correctly fitted to the appropriate sockets At high resolution DVI signals cannot normally be guaranteed beyond 5m cables due to the nature of the signal losses inherent in the DVI cables and connectors Datapath have added active equalization hardware on the x4 which is able to compensate for these losses and support cable lengths of up to 20m even at full dual link resolutions 330Mhz pixel clocks Lower resolutions will allow even longer cable lengths This allows more flexible positioning of the x4 relative to the source and the displays Once the LED indicators are illuminated the X4 will display the source across all four screens according to the configuration that is stored in its non volatile memory The x4 is factory configured to display the input image as a 2x2 split as shown in Fig 3 Output To connect to an analog output a DVI I VGA cables are required To connect to a DVI output a DVI D cable is required Configuring the x4 The x4 has a USB port to allow a host
21. m SENENERE oO O muumuum Toi MN nA 7 SENN n Biss ar JNHINNEDG V F Sync 5 i DVI I OUT 2 DVI D INPUT DVI I OUT 4 Power Device The unique USB device name that is connected is displayed in the Device group Itis possible to asso ciate a more user friendly name such as First Four Outputs The friendly name is stored in non vola tile storage on the x4 and can to help identify the device during future configurations Specific devices connected to your PC can be selected using the Select Device command on the File Menu The x4s will be listed by the USB Device or by a previously configured friendly name Device USB Name 2 7061973f000000 Friendly Name 2 7061973f000000 Fig 6 18 DVI D Input The DVI D Input group displays the current DVI mode that is being captured if any and the preferred mode that has been programmed into the x4 s EDID Use the Modify button to update the EDID The small square to the left of the current input resolution indicates whether the x4 has frame locked to the input source e Green The outputs are frame locked to the input dot clock and vertical sync e Grey The outputs are not frame locked DVI D Input Current EDID Preferred Mode B 1920x1080 59 939Hz 1920 x 1080 59 933Hz m Deol mk sets Fig 7 To boost the equalization hardware click on the Settings button and the following dialog is displayed Fig 8 x4 DVI D Input Settings Fig 8
22. maximise DVI cable lengths the CVT Reduced Blanking is recommended Selecting Custom allows the timing parameters to be edited It should be noted that you will need to select between definition of Pixel Clock or Vertical Refresh since these are mutually exclusive parameters Once edited clicking OK writes the preferred mode into the EDID but may not normally affect the input mode that is being captured It may be necessary to force the graphics device in the host machine to detect the new modes this can be done by selecting Detect on the Screen Resolutions dialog box Win dows 7 or by disconnecting the source from the x4 and reconnecting 20 All modifications to the Input settings can be saved as part of a vqs file removing the requirement to input the same settings again To save the settings select the Save command in the File menu To open a saved vqs file select the Open command Limitations Current No Signal Copy Timings Input Edid Preferred Mode Timing Standard CVT Reduced Blanking z Display Mode mm Horizontal Pixels 3860 Vertical Lines 4095 Verti Vertical Refresh 39 999 Scan Type Progressive Pixel Clock 500 250 MHz Format DVI Fig 10 Figures entered as the Input EDID Prefered Mode may exceed the internal bandwidth limitation of the x4 if this happens a warning is displayed in the form of the figures being highlighted pink as shown in Fig 10 21 Input Capture Regions
23. ocking to the input irrespective of the monitor EDIDs In this case the x4 can be configured to always output the mode that has been programmed as the default mode Selecting the Regions to Be Displayed Each output of the x4 can take its display data from any arbitrary rectangular region of the captured input image The factory default for these cropping rectangles configures the four monitors to display a quarter of the input as a 2x2 array and these proportions are maintained across different input resolutions For a 1080p input this means that 960x540 pixels from the input image would be up scaled by a factor of 2 in each direction if the selected output resolution was 1080p However if the input resolution were to change to 1600x1200 then for the same output monitor the x4 would upscale from an 800x600 region and would reprogram its scale factors to 2 4 horizontally and 1 8 vertically to support the same 1080p monitor The cropping regions can be assigned arbitrarily and can overlap the only restriction being that the resulting scale factor must be greater than 1 0 ie 1 1 or up scaled in either direction As an example it is possible to use the x4 to output four identical copies of the input signal providing the resulting output timings remain within the capabilities of the single link DVI outputs The regions of the input image to be displayed on a given output monitor can be programmed via USB by using the Datapath configuration app
24. right the third the bottom left etc This mode of operation can be used to drive four monitors in a 2x2 arrangement from a single high resolution input Replicate Each output displays the entire input image The output monitors can be driven atthe same resolution with different timings if necessary or a higher resolution There are no restrictions other than the resulting scale factor must be 1 1 or upscale in the region settings so it is possible to have regions overlapping or to program in gaps etc Additionally each region can have a transform such as rotation or flipping applied to it after cropping in order to support different output monitor orientations Please note that there may be instances where a setting stored in non volatile memory which was valid when it was stored ie the scale factors from input to output were 1 1 or greater may subsequently require down scaling if the resolution of the input increases In this case the firmware will adjust the scaling factors to give a 1 1 crop of the input centred on the original region In order to indicate that at least one output is no longer exactly honouring the programmed region setting the front panel status light will not be illuminated Scaling Optimisation Scaling Optimisation is used to optimise displays that have been scaled If the display is mostly text based Text should be selected This will ensure that the displayed text remains sharp after scaling If the display is
25. to ease the setup of the x4 1u by setting all four outputs to the exact same timings by replicating the the timings of the first output Push and hold the button for approx 3 seconds to activate the Output Framelock The three LEDs will flash to indicate the operation is successful If the first output is set to Use The Monitor s Preferred Mode the EDID timings will be sampled from the monitor and written into the x4 defaults Output 1 will then be set to Always Use the Default Mode If output 1 is set to Always Use the Default Mode no action is taken on this channel Output 2 3 and 4 will have their timing defaults overwritten with those from Output 1 and they will also be set to Always Use the Default Mode The onboard micro in the x4 will then enable the framelocking The x4 will now ignore the output monitor connections until it is changed using the x4 application Rear Panel A DVI D INPUT DVI I OUT 4 POWER Fig 2 Sync Sockets Not x4 1U The Sync sockets are provided for future genlock enhancements They should be left unconnected USB Socket The USB socket is used to connect the x4 to a PC via a USB connection using the supplied USB Type A to Type B cable Configuration of the x4 is programmable via an application utility allowing easy control of cropping scaling rotation and gaps 11 DVI D Input Socket The DVI D Input socket is used to connect the DVI input source to the x4 The x4 supports Du
Download Pdf Manuals
Related Search
Related Contents
Introduction Principle Storage and Stability MANUAL DE INSTRUCCIONES Toshiba TE2000 Laptop User Manual Copyright © All rights reserved.
Failed to retrieve file