Home
Product User Manual
Contents
1. Shortcut Key Function Set 71 preset Proportional P T OFF Set 73 preset 0S Park time OFF Set 74 preset 60S Park time ON Set 75 preset 120S Park time ON Set 76 preset Dome restart Set 77 preset Restore Factory Setting Set 78 preset 360 scan and tour scan speed is automatic Set 79 preset 360 scan and tour scan speed is high 20 sec Set 80 preset 360 scan and tour scan speed is middle 15 sec Set 81 preset 360 scan and tour scan speed is low 6 sec Set 82 preset Delete left right limit Set 84 preset Record Pattern scan 1 Set 85 preset Record Pattern scan 2 Set 86 preset Record Pattern scan 3 Set 87 preset Record Pattern scan 4 Set 88 preset Set cruise 1 Set 89 preset Set cruise 2 Set 90 preset Set cruise 3 Set 91 preset Set cruise 4 31 Set 94 preset Set color to black function Set 95 preset Close main menu Set 96 preset Access main menu Set 97 preset Set 360 scan the preset dwell 0S Set 98 preset Set 360 scan the preset dwell 5S Set 99 preset Set 360 scan the preset dwell 10S Call 71 preset Proportional P T ON Call 82 preset Start Cruise scan and switch the cruise scan direction Call 83 preset Delete all Presets Call 84 preset Start Pattern 1 Call 85 preset Start Pattern 2 Call 86 prese
2. 9096 3 Installation Preparations 3 1 Tool List The tools in the list will be used or not 1 Screws 2 Monkey wrench 3 Philips screwdriver 4 Straight Screwdriver 5 Wire stripper 6 Ladder 7 Electric drill 8 Socket head wrench 9 Hammer 10 Electric iron 11 BNC mail connector 3 2 Installation Preparation 1 Check the space and toughness of the site make sure that the environmental conditions meet the installation requirements for this product 2 Please check the space and toughness of the site before installing It should be able to bear 4 times the weight of the PTZ and its accessories 3 3 DIP Switch Setup 1 Default Pelco P D auto detected baud rate 2400bpx address 1 Detach the upper housing and bottom cover you can see DIP switch below DIP Switch Position Reset Position 2 Baud Rate Setup Decoder Switch 9 10 1 ON 0 OFF Switch 9 10 setting Max transmission Baud Rate 9 10 distance M 0 0 2400BPS 1800 1 0 4800BPS 1200 0 1 9600BPS 800 Auto detected 2400 1 1 600 1800 4800 9600 19200BPS Notice Please restart the camera after setting switch 3 When the DIP Switch 9th and 10th are ON the PTZ can automatically detected the baud rate 2400 4800 9600 19200 4 Setup of the OSD Menu 4 1 Display Boot UP Info Before control the PTZ check the protocol baud rate address and RS485 data cable Default protocol PELCO D address 1
3. 107 108 109 110 111 112 114 115 116 117 118 119 121 125 127 129 130 132 134 135 136 137 138 139 140 141 142 28 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 174 175 176 177 178 179 180 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 29 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 30 251 1 1 50 dep 1 252 0 0 T 1 4 1 T 1 253 1 08 1 5 1 1 1 1 254 0 1 L1 14181 255 1 cL 344 All ded Notice Some protocols and address start from 0 Try 1 of address code when can t control APPENDIX II Shortcuts Key Chart
4. The illumination value Unit Lux User can not edit e IR START SET 006 Default Open IR light illumination value Range 0 8 Unit Lux e IR CLOSE SET 012 Close IR light illumination value Range 12 20 Unit Lux 25 APPENDIX I DIP SWITCH SETTING DIP Switch consists of 8 numbers from 1 8 use 8421 binary cod max 255 address When the switch is in the ON position the number from 1 8 corresponding to 1 2 4 8 32 64 128 For example if you set 1 3 5 7 switch to the ON position the corresponding address will be 1 4 16 64 85 please refer to the blow details Sheet 1 1 ON 0 OFF DIP switch Address ID Switch number 1 number 8 IP switch Address KI ID Switch number number 8 1 6 6 10 12 14 16 18 20 21 22 23 24 25 26 27 28 26 40 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 71 78 79 95 81 82 83 84 85 86 87 88 27 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106
5. baud rate 2400 PROTOCOL PELCO PD BAUD RATE 2400BPS CAMERA ID 001 CAMERA S N 0000000001 VERSION V1 02 FAN SPEED 6500RPM STARTING When starting the PTZ will check the below information Level self check Success Vertical self check Success Camera type SONY Success When finished the above information will disappear and the dome is under the control status Notice When the PTZ passed the level and vertical self check the screen show success if not error and please contact our technician 4 2 Enter the OSD Menu In the condition of standby status calling preset 95 enters into the main menu Using the direction key to select item or start the configuration Right key for enter left key for exit the current setting The Main menu as shows SYSTEM LENS CAMERA PAN TILT AUTO RUNNING PRIVACY MASK ALARM LANGUAGE IR SET EXIT Setting preset 95 can exit the OSD Menu 6 4 3 SYSTEM lt Main gt lt SYSTEM gt SITE INFO DISPLAY SETUP BOOTUP SCREEN PASSWORD SET DEFAULT SYSTEM REBOOT RTC TIME SET RTC TIMER RUNNING BACK System info includes following settings lt SITE INFO gt User can setup the dome s ID site name and broadcast address lt DISPLAY SETUP gt User can setup to display the Screen information or not DISPLAY BOOT UP INFO User can setup to display system information when booting lt PASSWORD gt User can setup the password o
6. 4 4 LENS 45 CAMERA 14 4 6 E 15 4 7 AUTO RUNNING eba k nek 16 4 8 PRIVACY MASK Need support by camera 23 4 10 LANGUAGE 4 11 ZOOM SET APPENDIX I DIP SWITCH SETTING 26 APPENDIX II Shortcuts Key Charti 31 APPENDIX III Trouble Shooting 33 1 Instruction This product can be widely used in intelligent building bank security urban roads airport terminals and bus stations and also are able to satisfy various demands from any square and activities occasion 1 1 Safety Instructions Make sure to read the user s manual before using the product Always confirm to national local safety codes during installation Only qualified and experienced person can carry on this installation Use reliable tools otherwise may lead to dangerous incidents Make sure that the environmental conditions meet the installation requirements for this product Please check the space and toughness of the site before installing It should be able to bear 4 times the weight of the dome and its accessories Please keep all the original dome package materials for future repacking and transporting 1 2 Warnings Do not install this speed dome in hazardous places whe
7. manual 005 255 The dome will start auto iris that number of seconds after user manually adjust iris lt DAY NIGHT gt IR Auto Change function need camera support Set the dome color black amp white mode Color mode is suitable to work in daytime because it needs higher illumination Light sensitivity of black amp white mode is much higher It is suitable to work at night without illumination but the video is black and white NOTE This setting is only for the day night camera There are 4 options lt AUTO gt The dome will automatically change modes according to the environment illumination lt COLOR gt The dome is always in color mode lt BLACK amp WHITE gt The dome is always in Black and White mode lt IR AUTO CHANGE gt The dome is controlled by the IR lights when the IR lights opened the mode auto change to Black and White Should need camera supported 13 P N gt Show the current camera P N PAL NTSC The PTZ can automatically detected some of the camera Signal mode if not please set manually 4 5 CAMERA lt Main Menu gt gt lt CAMERA gt WHITE BALANCE AUTO BLC MODE BACK EXIT 4 5 1 WHITE BALANCE WHITE BALANCE is normally compensated for by the automatic white balance gain control In some lighting conditions user may want to manually adjust the red and blue settings for optimal viewing There are 6 options some cameras just support part of modes below AU
8. 1 Focus is in manual state 2 Extreme zoom magnification 3 Dome cover is dirty 1 Reset the focus mode to Auto 2 Downsize zoom proportion 3 Clean the dome cover No night vision 1 Camera is in Color state 2 backlight on the top or back of the dome camera 1 Reset the day night function to Auto 2 Remove the direct light source 33
9. PROVISUAL IR High Speed Dome Camera PTZ 9636IR User Manual Packing Name QTY PTZ 1 Wall Bracket include fixed Screws 1 Holder 1 DC12V 5A power supply 1 Screws 4 PM8 25 socket head screws 4 User s manual 1 Warranty Card 1 Conformity of quality 1 Description 1 pc superpower LED IR light 6 pcs LED Array IR lights Superpower LED IR light equipped with big or small lens the big lens minimum Angle is 5 to secondary condense the light this model can fully gather IR lights into small angle and emit to far distance and the effect is excellent and night vision distance is up to 150 meters Contents I Instr ction 2 2 2 e e de 1 1 1 Safety Instructions eere eee esee 1 1 2 Warnings 1 2 Features 2 2 1 Product Features eere ee stets nen en e tatnen enn 2 2 2 Specifications 3 Installation Preparations E ee 4 3 1 Tool List 43y wak ea U KE KC HE EK b N SU HEVENAV AK 4 3 2 Installation Preparation s srresssseseseeseeeeseseese 4 3 3 DIP Switch 5 4 4 Setup of the OSD Menu sese 5 4 1 Display Boot UP Info eee eee eee esten 5 4 2 Enter the OSD Menu 4 3 SYSTEM
10. RE ID gt The dome works when receives any of those ID The dome s broadcast ID is 255 user cannot modify lt BACK gt return to upper menu lt EXIT gt exit the menu 4 3 2 DISPLAY SET lt Main Menu gt gt lt SYSTEM gt gt lt DISPLAY SETUP gt SITE NAME OFF PRESET TITLE OFF PATTERN NAME ZOOM OFF ORIENATATION OFF TEMPRETURE OFF ZONE NAME OFF RTC TIME OFF BACK EXIT lt SITE NAME gt Choose to display site name lt PRESET TITLE gt Choose to display preset position lt PATTERN NAME gt Choose to display pattern name lt ZOOM gt Choose to display the zoom or not lt ORIENTATION gt Choose to display the current lens direction or not lt TEMPRETURE gt Choose to display the current temperature or not lt ZONE NAME gt Choose to display the current zone name or not lt RTC TIME gt Choose to display the date and time or not 4 3 3 DISPLAY INFO Main Menu gt gt lt SYSTEM gt gt lt DISPLAY BOOT UP INFO gt PROTOCOL PELCO PD BAUD RATE 2400BPS CAMERA ID 001 CAMERA S N 0000000001 VERSION V1 02 FAN SPEED 6000RPM CALL PRESET 1 TO BACK Enter into Boot up info displays to check current setup call preset 1 to return to upper menu 4 3 4 PASSWORD Main Menu gt gt lt SYSTEM gt gt lt PASSWORD gt INPUT PASSWORD eee CONFIRM EA ee PSWD PROTECTION OFF BACK EXIT l
11. RUNNING gt DATE Y M D 000000 5 000000 PRESET 001 lt DATE and TIME gt Setup time running time 24 hour lt ACTION gt Choose one function from lt PRESET gt lt ZONE gt lt TOUR gt lt PATTERN gt to run lt BACK gt Back to the upper menu lt EXIT gt Exit the current menu 4 4 LENS Main Menu 2 LENS ZOOM SPEED HIGH DIGITAL ZOOM OFF JOYSTICK AF AI AI AF RESUME TIME 005 AIRESUME TIME 005 DAY NIGHT AUTO CAMERA P N PAL BACK EXIT lt ZOOM SPEED gt Set the zoom speed level to HIGH or LOW lt DIGITAL ZOOM gt Turn On Off the Digital Zoom lt JOYSTICK AF AI gt Set up Auto Focus or Auto Iris 12 BOTH Joystick movement triggers both auto focus and auto iris lt FOCUS gt Joystick movement triggers auto focus only lt IRIS gt Joystick movement triggers auto iris only lt NONE gt Joystick movement triggers none of the functions lt AF RESUME TIME gt This item sets the time to restore auto focus after focus is manually changed The default setting is 005 options are Off Never restore auto focus after switch to manual 005 255 The dome will start auto focus that number of seconds after user manually adjusts focus lt AI RESUME This item sets the time to restore auto iris after iris is manually changed The default setting is 005 seconds options are Off Never restore auto iris after switch to
12. SET 1 TO RETURN CONFIRM SIZE Using up down left and right key to adjust the size of the mask then call preset 1 to confirm and return e lt REMOVE CURRENT MASK gt Remove current mask then the black lump will disappear e REMOVE ALL MASK gt Remove all masks then all the black lump will disappear 4 10 LANGUAGE Main Menu LANGUAGE gt LANGUAGE English BACK EXIT The dome camera supports OSD Menu with Chinese English Enter into the Language move the cursor up and down to choose language press the left direction key to confirm 4 11 ZOOM SET Main Menu gt IR ZOOM SET 24 IR AUTO IR ZOOM SET 1 006 IR ZOOM SET 2 010 PRESENT LUX 000 IR START SET 006 IR CLOSE SET 012 BACK EXIT e MODE gt AUTO OPEN CLOSE lt AUTO gt Default When the detected signal value from the IR sensitive below the value of IR Start the IR dome automatically open the IR lights lt OPEN gt Open the IR lights forcibly No influence from the detected signal value lt CLOSE gt Close the IR lights forcibly No influence from the detected signal value Notice The function only effective in lt LENS gt gt lt DAY NIGHT gt gt lt IR CHANGE gt mode e lt IR ZOOM SET 1 gt 006 The second section IR Zoom value Range 0 the maximum optical zoom e lt IR ZOOM SET 2 gt 010 The third section IR Zoom value Range 0 the maximum optical zoom e lt PRESENT LUX gt
13. TO Auto White Balance default setting MANUAL Manually set the red and blue values setup from 000 to 255 ATW Auto track White Balance OPW Once touch White Balance OUTDOOR Suitable for outdoor use INDOOR Suitable for indoor use 4 5 2 BLC MODE Need support by camera If the backlight is bright the objects in the center of the picture may appear dark The dome can auto adjust the brightness of the whole image according to the brightness of the center point Thus backlight compensation can increase the brightness of the objects in the center of the picture Select lt BLC SET gt and choose the right key to access the sub menu as below 14 BLC QTY 000 WDR OFF BACK EXIT Adjust the data the choose from 000 255 lt WDR gt ON and OFF the camera s WDR function 4 6 PAN TILT Main Menu gt gt lt PAN TILT gt AUTO STOP TIME OFF SPEED AMPLIFY 032 PROPORTIONAL P T ON SET NORTH BACK EXIT lt AUTO STOP TIME gt For some particular protocols the dome will not stop moving even there is no operation on CCTV Tester This menu sets the time after which the dome receives last control command Off Disable this function 001 255 The time second that dome will stop moving without receiving any commands e SPEED AMPLIFY gt Some protocols controlling speed is much lower set SPEED AMPLIFY gt to accelerate domes movement Op
14. e RUN Start current zone scan repeatedly before receiving new command Note 1 PTZ default tour scan route is the left limit clockwise direction if user finds out the route is wrong could call number 82 preset again when the tour scan run to the critical point PTZ will scan as reverse direction 2 360 scan pan speed and preset cruise pan speed is sharing PTZ running by the new setting speed For instance call 360 scan pan speed is middle after then recall the preset cruise pan speed is high and when the user recalls 360 scan the pan speed becomes high 4 7 6 PARK TIME The camera will run certain function automatically if there is any operation for a longtime 22 05 PARK TIME 605 PARK TIME ON 605 120S PARK TIME 1205 4 7 7 lt RUNNING TYPE gt Set the run type after the idle time users can choose Preset Tour Pattern or Auto Note Time running available only lt IDLE TIME and lt RUNNING TYPE gt are both ON state 4 8 PRIVACY MASK Need support by camera lt Main Menu gt gt lt PRIVACY MASK gt MASK NUMBER 001 PRIVACY MASK SETUP REMOVE CURRENT MASK REMOVE ALL MASK BACK EXIT e lt MASK NUMBER gt Set and edit the current mask zone number from 001 008 e lt PRIVACY MASK SETUP gt Enter privacy mask setup to edit and confirm CALL PRESET 1 TO RETURN CONFIRM 23 Call preset 1 to confirm your setup then you will see below sub menu CALL PRE
15. eat runs steady no shaking Support 4 groups cruise scan 27 presets group 4 group patterns one scan 360 continuous scan and 360 intermittent scan IR lights automatically adjust the light intensity according to the zoom speed to reduce the dark angle and flashlight effect The upper dome adopts 7 aluminum alloy structure better magnetic shield and heat radiation The under part dome adopts full metal class points bin type design fast heat dissipation and anti mist noninterference light source images and long life span IR light 2 2 Specifications Output DC12V 45 SA Power Supply Input AC100 240V 50 60Hz Max Power IR off 15 31W Sync system Internal Sync Pan Speed 0 08 240 S Tilt Speed 0 08 240 S Pan Range 0 360 Continuous Tilt Range 0 90 180 auto flip Preset 128 Preset Accuracy lt 0 1 Tour 4 27 presets tour Pattern 4 Zone 1 Protocol RS485 Communication PELCO D P auto detected Baud Rate 2400bps 4800bps 9600bps 19200bps Address 1 255 RTC Set any key at any time A Superpower LED Default 1 5 times open the near distance lights 6 9 times open the near distance IR Light switch and middle distance lights after 10 times turn off the near distance lights open the middle distance and far distance lights Work Temperature Indoor 0 C 450 C Outdoor 10 C 50 C Work Humidity
16. n 5s the speed dome will run as the given route repeatedly before receiving new command 10S 90 intermittent scan then dwell on 10s the speed dome will run as the given route repeatedly before receiving new command 20 Special note 360 scan stay time preset cruise stay time is sharing PTZ running by the new setting time For instance call 360 scan stay time is 5 seconds after then recall the preset cruise stay time is 10 seconds then when the user recalls 360 scan the stay time become 10 seconds SPEED gt High 20 S Middle 15 S Low 6 S Auto Does the camera s proportional P T speed lt RUN gt The speed dome will run as the dwell time and speed repeatedly before received new command 4 7 5 ZONE lt Main Menu gt gt lt AUTO RUNNING gt gt lt ZONE gt TITLE 23 LEFT LIMIT 25 RIGHT LIMIT 148 PAN SPEED HIGH REMOVE CURRENT RUN BACK EXIT e TITLE To set current zone number 16 bit can be set up by the number 0 9 and the letters A Z of any combination e LEFT LIMIT Set the right edge of region A 21 CALL PRESET 1 BACK CONFIRM Move the camera left limit position to confirm and return e lt RIGHT LIMIT gt Set the right edge of region B CALL PRESET 1 TO BACK CONFIRM e PAN SPEED High 20 S Middle 15 S Low 6 S Auto Does the camera s proportional P T speed REMOVE CURRENT gt Delete current zone
17. preset lt TITLE gt To set current preset title 16 bit can be set by the number 0 to 9 and the letters A Z of any combination lt SET CURRENT gt Select this item to set the preset position and zoom The following menu will pop up when lt Set Current gt is selected CALL PRESET 1 TO BACK CONFIRM Move to the desired position and zoom to a suitable level call preset 1 to save the current preset and return 17 lt REMOVE CURRENT gt Delete the preset with the number and title display above 4 7 2 TOUR lt Main Menu gt gt lt AUTO RUNNING gt gt lt TOUR gt TOUR NUMBER 001 DWELL 003 EDIT RUN BACK EXIT The dome camera will run repeatedly as the given sequence of presets at certain dwell time by one command Max 4 tours available 27preset tour lt TOUR NUMBER gt Set current tour number from 001 004 lt DWELL gt Set the default dwell time from 001 255 seconds for each preset User can still set independent dwell time for each preset in editing preset mode lt EDIT gt Edit presets and corresponding dwell time in a tour as follows PRESET DWELL 001 003 002 003 003 003 004 003 005 007 006 003 007 004 008 003 000 003 000 003 000 003 000 003 000 003 000 003 000 003 SAVE AND BACK CANCEL AND BACK 18 There are three group numbers the left side is preset number the right side is dwell time tour from left to right up to down in the order to run preset when the pre
18. r change menu password SET DEFAULT gt User can setup restore factory default settings but the preset positions will be retained SYSTEM REBOOT gt After change dome ID or adjust deviation between two preset positions user has to reboot the system to activate TIME SET Set the present date and time lt RTC TIMER RUNNING gt At a specified time to run the defined function 4 3 1 SITE INFO lt Main gt lt SYSTEM gt gt lt SITE INFO gt NAME GXAAF DOME 001 DOME ID OPT SOFT SOFTWARE ID 001 HARDWARE ID 000 BROADCAST ID 255 BACK EXIT is the title of the dome Assigning a name to dome helps user to remember which dome it is Max 16 digits Setting with number from 0 9 and letter from A Z Move the cursor to lt SITE ID gt and then move the joystick right to enter dome ID setting lt DOME ID OPT gt Setting the address to control the dome user can choose from SOFT and HARD gt SOFT when choose this the SOFTWARE ID is effective while the HARDWARE ID is ineffective gt HARD when choose this the HARDWARE ID is effective while the SOFTWARE ID is ineffective SOFTWARE ID shows the current software ID user can modify and choose from 001 254 lt HARDWARE ID gt shows the current physical ID it is decided by the DIP Switch and user cannot modify lt BROADCAST ID gt shows the current ID The ID functions the same as dome s lt SORTWARE HARDWA
19. re combustible or explosive materials are stored or used Do place the camera shaking desk Make sure no uncertain object or fluid substances get inside the unit This speed dome runs DC 12V connect it to higher lower voltage Please check RS 485 cable Do not turn power on before finishing installation Do not disassemble any part of the items Use soft towel to clean the down cover when necessary do not use caustic detergent To protect CCD avoid facing the camera directly to the strong light To prevent damage do not drop the unit or subject to strong shock or vibration 1 2 Features 2 1 Product Features CCD Sensor 1 3 Sony Effio CCD Color 960H Zoom Magnification 36X Optical zoom Day amp Night function The camera is configured to switch to the black and white mode automatically under low light conditions and at night Various focus mode Auto Focus Manual Focus Semi Auto Focus Max 360 sec high speed Pan Tilt motion Automatic flip Adaptive PELCO P D protocol IR start illumination menu can be adjusted Auto running memory against power outage RTC function call any functions at any time Support 128 preset positions and support lens preset OSD menu user friendly and easily operation Compass function proportional zoom and auto flip function Built in double devices for lightning proof and surge proof Adopt advanced stepper motor less h
20. set number is set to lt 000 gt the current preset is skipped e SAVE AND BACK gt Save the tour and back e CANCEL AND gt Quit without saving and then exit to the upper menu e lt RUN gt Run the current tour repeatedly before receiving a new control command e BACK Back to upper menu 4 7 3 PATTERN Main Menu AUTO RUNNING PATTERN PATTERN NUMBER 001 RECORD RUN BACK EXIT There are max 4 patterns and the dome camera can record all regular operation in 3 minutes at least The command will drive the speed dome runs as given route repeatedly e PATTERN NUMBER gt Set current pattern number from 001 004 lt RECORD gt Edit the current pattern s running route and record all operation in 3 minutes at least 19 CALL PRESET 1 TO BACK CONFIRM 180S 000 RECORD e 1805 Remaining record time e 00090 The recording space The record time will decrease while the space increases User can call preset 1 to back to the upper menu Notice Any of the time and space is finished even not call preset 1 the recording is end and exit and saved the recording e lt RUN gt Run current pattern repeatedly until other command received 4 7 4 360 SCAN lt Main Menu gt gt lt AUTO RUNNING gt gt lt 360 scan gt 360 SCAN DWELL 0S PAN SPEED HIGH RUN BACK EXIT lt 360 SCAN DWELL gt 05 360 continuous scan 5S 90 intermittent scan then dwell o
21. t Start Pattern 3 Call 87 preset Start Pattern 4 Call 88 preset Call cruise 1 default number 1 16 preset Call 89 preset Call cruise 2 default number 17 32 preset Call 90 preset Call cruise 3 default number 35 48 preset Call 91 preset Call cruise 4 default number 49 64 preset Call 92 preset Set left limit Position Call 93 preset Set right limit Position Call 94 preset Camera IR CUT switch Call 95 preset Open main menu Call 97 preset Call all valid presets cruise Call 98 preset Call 360 scan Call 99 preset Preset Error Correction 32 APPENDIX Trouble Shooting Troubles Reason Solution No action when power on 1 The power supply is not connected correctly 2 The fuse is broken 1 Correct the connection 2 Check the power supply is connected or confirms if the plug connects well 3 Replace the fuse Self testing and image are normal but the dome is out of control 1 The dome DIP switch setting is incorrect 2 RS485 cable is disconnected or reversed 3 Incorrect RS485 cable wiring 1 Reset the DIP Switch according to the DIP switch chart 2 Check 485 bus controls 3 Check the wiring 4 Check the control device Some function is out of control 1 RS485 communication signal is not balance 2 Control protocol is not compatible 1 Connect 120Q balance resistance 2 Reset protocol Unclear image
22. t INPUT PASSWORD gt Factory default is 123456 Move joystick to enter submenu then input the old password If you forget the password after changing please contact the supplier for the master password The cursor will flash if the old password is correct and then input the new password If the old Password input is not correct you will not be able to change the password 10 lt CONFIRM gt Re input the new password and confirm If the input is not the same as the first time input the system will remain the old password lt PSWD PROTECTION gt Switch off the password protection When it is user need to enter password to access main menu or save preset through keyboard e lt BACK gt return to upper menu lt EXIT gt exit the menu 4 3 5 SET DEFAULT Main Menu gt gt lt SYSTEM gt gt lt SET DEFAULT gt Select SET DEFAULT to restore factory default setting 4 3 6 SYSTEM REBOOT Main Menu 2 SYSTEM SYSTEM REBOOT gt Select SYSTEM REBOOT gt to reboot the dome 4 3 7 TIME SET Main Menu 2 SYSTEM RTC TIME SET gt DATE Y M D 00 00 00 TIME M S 0000 00 Use left and right keys to move the cursor to desired item use and down keys to change the current cursor value Notice The default date is 2000 to 2110 and the year beyond is unable to set 11 4 3 8 RIME RUNNING Main Menu gt gt lt SYSTEM gt gt lt RTC TIMER
23. tions are as below Off Disable this function 01x 32x Speed amplify from 01 32x 15 Notice The above two functions is available at present e PROPORTIONAL The dome moves at a speed of certain degree per second Objects on screen move much faster in wide scope than in telescope Even too faster in some case This function decreases the dome movement speed while zooming in e lt SET NORTH gt User can set orientation by using joystick to position north When select SET NORTH following menu will pop up CALL PRESET 1 TO RETURN CONFIRM Adjust the lens to desired position and call preset 1 to confirm and return e BACK Back to upper menu 4 7 AUTO RUNNING Main Menu 2 AUTO RUNNING PRESET TOUR PATTERN 360 SCAN ZONE PARK TIME 05 PARK ACTION OFF BACK EXIT 16 4 7 1 PRESET Main Menu gt gt lt AUTO RUNNING gt gt lt PRESET gt PRESET NUMBER 001 TITLE PRESET 001 SET CURRNET REMOVE CURRENT BACK EXIT In this function the value of pan tilt speed and camera parameters could be stored in the preset so that you can call them when needed 128 presets can be set It could also setup by shortcuts of control system lt PRESET NUMBER gt Display current preset number the value ranges from 001to 064 Except preset 33 and 34 and 101 to 164 Note As the number 33 34 preset has other functions in PELCO protocol so user could not set number 33 and 34
Download Pdf Manuals