1. O O O OO A MC A O I Y Y A SEENEN www micromatic com 1 866 9 12 ww Data Plate The data plate is located inside the unit near the top front left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify the particular features of the unit and is of great benefit to installers operators and maintenance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation If service is reguired call 1 800 544 0400 Service agent will reguire the data plate information Electrical Connections Refer to the amperage data in this manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information A protected circuit of the correct voltage and amperage must be run for connection of the supply cord Unit must be grounded and connected in accordance with NEC Article 422 Appliances Wr FIRST DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If unit is still running when power is off disconnect power at the circuit breaker before unplugging the unit WARNING Uni
2. Symbol Operation Compressor enabled Flashing Anti short cycle delay enabled AC parameter Flashing Dripping in progress Flashing Programming mode Flashing Programming mode www micromatic com 1 866 327 4159 ww How See The Set Point 1 Push and immediately release the SET key the set point will be displayed 2 Push and immediately release the SET key or wait about five 5 seconds to return to normal display How To Change The Set Point 1 To change the set point number push the SET key for more than two 2 seconds 2 The number of the set point will be displayed and the E or F LED will blink 3 To change the set number push the arrow up or down keys within ten 10 seconds 4 To hold the new set point number push the SET key again or wait ten 10 seconds How To Change A Parameter Number 1 Enterthe Programming mode by pressing the SET keys forthree 3 seconds the C or F LED will blink 2 Select the required parameter Press the SET key to display the number 3 Use the up or down arrow keys to change the number 4 Press SET to store the new number and move to the following parameter To exit Press SET 57 or wait fifteen 15 seconds without pressing a key NOTE The set number is stored even when the procedure is exited by waiting for the time out to expire How To Enter The Hidden Menu 1 Enter the programming mode by pressing the SET keys for three 3 seconds t
3. Voltage 115 60 1 Blue LED Whites Red LED Reds 42 48 5 5 8 8C 55 65 F 12 7 18 30 Refrigerant R 134a ETL Listed Charge oz Grs 10 5 300 18 gauge stainless steel top 22 gauge solid self closing doors black vinyl over 24 gauge steel front sides and back Interior 20 gauge stainless steel floor rugged false floor reinforced frame 24 gauge galvanized walls Ventilation Front and side ventilated Automatic condensate evaporator no drain connection required Evaporator condensate has been plumbed to a condensate pan located in the compressor housing Insulation Foamed in place using high density CFC free polyurethane 1 1 2 top walls and floor Castors or 6 Fixed legs TOP FRONT SIDE 151 1mm m 59 1 2 1302mm 51 174 946mm 37 1 4 590mm A i d 284mm 23 S 51mm 717mm TE 2 28 1 4 5 www micromatic com 1 866 327 4159 ww Specifications 8 Dimensions MDD23W Series TBD 3 Hole Diameter 1 115 60 1 NEMA 5 15R Color coded Digital Thermostats 2 Blue LED Whites amp Red LED Reds ZEN Temperature Range Whites 42 48 5 5 8 8C 55 65 F 12 7 18 3C R 134a Approval ETL Listed 10 5 300 18 gauge stainless steel top 22 gauge solid doors black vinyl over 24 gauge steel front sides and back Interior 20 gauge stainless steel floor rugged false floor reinforced frame 24 gauge galvanized walls
4. Automatic condensate evaporator no drain connection required Evaporator condensate has Plumbing been plumbed to a condensate pan located in the compressor housing Foamed in place using high density CFC free polyurethane 1 1 2 top walls and floor Mobility Castors are standard and not removable TOP FRONT SIDE 826mm 31 32 172 991mm Hole Center 39 308mm 12 1 8 258mm 1366mm 10 1 8 1067 mm 604mm 53 3 4 42 23 3 4 85mm www micromatic com 1 866 327 4159 6 ww Keg Temperature Storage Serving Storage It is important to understand that when the keg of wine is delivered it must be properly stored White wine must be stored inside the cooler as soon as possible as it may take as many as 24 hours for the temperature to be reduced to the desirable range e It is recommended to store both reds and whites at room temperature approximately 72 F e Wine kegs stored in a walk in cooler approximately 38 F may dramatically effect the time it takes to reach the desired serving temperatures e Allow 24 hours for kegs to reach the desired serving temperature 45 F for whites and 55 F for reds e Just like a bottle of wine the best temperature to store white or red wines is between 45 60 F neither too cold nor too warm Remember wines are both cold and heat stabilized Most white wines are cold stabilized to approximately 36 F If the wine gets any colder for any len
5. MICRO MATIC y W N UY MDD23W Series MDD58W Series Pro Line Wine Dual Temperature Wine Keg Storage amp Dispensing SAFETY A FIRST PLEASE READ BEFORE USE Installation Use Maintenance Guide ww Wine On Tap Keg wine is the smart choice Fine varietal wines are now in kegs Serve wine at the optimal temperature the vintner intended it to be enjoyed Pro Line Wine units feature dedicated dual temperature zones one for whites 45 F and one for reds 55 F Keg wine is a great value with minimal waste and stays fresh until poured Increase Sales Dispense Wine Any Place Any Time Capture incremental sales e Open up new opportunities for profitability Dispense Ouality Wine Pour consistency from the frst to the last glass Once tapped keg wine stays fresh for up to 6 weeks e Eliminate open bottle degradation and oxidation Operating Efficiency e No corks to pull no bottles to stock or recycle Realize maximum product yield e Low maintenance cost e Small footprint 26 bottles per keg af a i r ml A a ba A y Yrm emea g 1 vww micromatic com gt 1 866 327 4159 Installation Use amp Maintenance wcro manic Table 0f Contents Receiving amp INSpecting rancia Page 3 LOCATON ta Page 4 SEN Page 4 e Install Wine Font e Install Keg Tapping Kit Specifications DIMENSIONS smc YU GY Fn MO Page 5 Keg Temp
6. conditions set forth in this Warranty have been satisfied and whether or not the applicable Warranty is in effect Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a supplier or b are abused Application of this Warranty is further conditioned upon the following Installation The Eguipment must be properly installed in accordance with Micro Matic s installation procedures No Alteration The Eguipment must not have been modified or altered from its condition at the date of original installation Any alteration from factory settings on thermostats will void warranty Use Micro Matic eguipment in not designed for personal family or household purposes and its sale for such purposes is not intended in the event the eguipment is so used this warranty shall be null and void and the eguipment shall be deemed to have been sold as is where is without any warranty of any kind including without limitation any warranty of title non infringement merchant ability or fitness for a particular purpose Proper Maintenance and Operation The Eguipment must be properly maintained and operated in accordance with Micro Matic s maintenance and operating procedures All service labor and parts must be acguired from Micro Matic or its authorized service representative for the User s area This warranty is void if failure is a direct result of handling an
7. White Wine Side dixell XR02CX CE L Black White COM VC Z F www micromatic com 1 866 327 4159 MICRO MATIC o Wiring Diagram MDD58W Series JB 1 TA Tl T2 w o om gen ce mennu TA emos RSR z Ret ewo RED Display Red Wine Side dixell XR02CX CE L COM VC ll www micromatic com 1 866 327 4159 Black BLUE Display White Wine Side Pro Line Wine White 18 ww Parts Listing Item Part Description MDD23W MDD58W Castors amp Legs aron 3M0013 Castor w o B BD 3 L gt iy 603313M0014 Castor with B D 3 Od Y O e Compressors 0000000000 602121M0073 Compressor EM55HNX Poa fo 602101M0082 Start Kit Compressor EM55HNX 1 mom neien 602101M0020 Compressor NE6187Z i 602101M0035 Start Kit Compressor NE6187Z 1 AA Condensers amp Others amp Others SEE TT 6029020009 Condenser Coil 1 om Fan Condenser 1 2 eoem li w17301M0036 Condensing Unit 7 omg alack Let Dooce 1 weus Black Right DoorKt weu Black DoorKit 1 0030540133 Door Spacer 1 wem ue DoorGasket 050019 Door Central Gasket 1 AA AE noogwoo20 Right Self Closing Hinge Kit 1 wem Right Hinge Kit ES era KSE 602105m0003 Fan Evaporator 120V 1 60290160009 Evaporator Coil zm Evaporator Coil 1 o 602713M0002 Grid
8. become defective Micro Matic will cover labor cost within one year from the Warranty Commencement date or 15 months from shipment date whichever occurs first Micro Matic shall bear all labor costs in connection with the installation of these replacement parts provided that the installation is conducted by Micro Matic or its authorized representative Charges for warranty travel time to round trip total of 2 two hours or up to 100 miles total Any charges exceeding those stated herein or overtime rates must have prior authorization by Micro Matic Additional Four Year Compressor Part Warranty In addition to the warranty set above Micro Matic warrants the compressor part only for an additional four 4 years based on the installation date This warranty is for defects both in workmanship and material under the normal and proper use and maintenance service The four 4 year extended warranty only applies to hermetically sealed parts of the compressor and does not apply to any other part or component including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component The original purchaser shall be responsible for returning the defective compressor to Micro Matic prepaid This warranty shall be void if the compressor in Micro Matic s sole judgment has been subjected to misuse neglect alteration or accident operated contrary to the recommend
9. performing maintenance repair or cleaning the condensing unit Disconnect unit from power supply Remove compressor cover panel and carefully blow out any dust or debris on or around the condensing unit Use a vacuum or compressed air to blow though the condenser coil e THE CONDENSER MUST BE CLEANED AT REGULAR INTERVALS 30 60 DAYS FAILURE TO DO SO CAN CAUSE COMPRESSOR MALFUNCTION AND WILL VOID WARRANTY If you keep the condenser clean you will minimize your service expense and lower your electrical costs Failure to maintain a clean condenser coil will cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Gasket Maintenance Gaskets reguire regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soapy water e Avoid full strength cleaning products on the gasket as this can cause it to become brittle and prevent a proper seal Never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and do not reguire the use of tools or authorized service persons Installation Use amp Maintenance 16 ww Wiring Diagram MDD23W Series E O OE Done ewa o caw E eebe RED Display Red Wine Side BLUE Display
10. Fan Evaporator 2 2 www micromatic com 1 866 327 4159 ww Parts Listing Item MDD23W MDD58W Part Description Controllers 602135M032 Thermometer Digital 602135M0033 Thermometer Digital 602125M0034 Inner Side Panel Heater o M10917M0549 Bottom Panel ea M10917M0621 Inner Side Panel a a M10917M0567 Side Panel ey o M10917M0133 Back Panel 00 00 M10917M0164 Back Panel ni o M10913M0500 Top Panel 603305M0005 Separator Handrail ui 600301M0032 Plastic Bottom Protector Plastic Bottom Protector 00 a 602 Distributor 604313M0002 Air Distributor 4 Ways 2 M10917M0503 Black Handle Door Hardware Bolt Hex M 4 DOMO 6 12 Bolt M6x45 4 o O emm wa Capillary Tubes eg 6007020003 Capillary tube 0 42 x 9 5 FT A 6007020004 Capillary tube 0 54x5 9FT 1 e Installation Use amp Maintenance 20 ww Notes 21 www micromatic com 1 866 327 4159 QUMICRO MATIC Warranty For warranty service call 1 800 544 0400 Please have the model number and serial number Warranty Claims Procedure If there is a defect in material or factory workmanship covered by this Warranty reported to Micro Matic during the period the applicable Warranty is in force and effect Micro Matic will repair or replace at Micro Matic s option that part of the Equipment that has
11. ations specified by the Unit manufacturer repaired or altered by anyone other than Micro Matic in any way so as in Micro Matic s sole judgment to affect its quality or efficiency or if the serial number has been altered defaced or removed This warranty does not apply to a compressor in any unit that has been moved fro the location where it was originally installed Parts Warranty Coverage Micro Matic warrants all new machine parts produced or authorized by Micro Matic to be free from defects in material and workmanship for a period of 90 days from the Warranty Commencement Date If any defect in material and workmanship is found to exist within the warranty period Micro Matic will replace the defective part without charge Defective parts become the property of Micro Matic Micro Matic will have no responsibility to honor claims received after the date the applicable Warranty expires Notwithstanding the foregoing any claim with reference to the Eguipment or any parts therefore for any cause shall be deemed waived unless submitted by the User to Micro Matic within thirty 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Micro Matic will have the right at its own expense to have its representatives inspect the Eguipment at the User s premises and to request all of User s records pertaining to the Eguipment to determine whether a defect exists whether the
12. d or transportation fire water accident misuse acts of god attempted repair by unauthorized persons improper installation if serial number has been removed or altered or if unit is used for purpose other than it was originally intended Failure to comply with any of these conditions will void this Warranty In addition this Warranty does not cover defects due to apparent abuse misuse or accident Installation Use amp Maintenance 22 amp MICRO MATIC o www micromatic com 1 866 327 4159
13. erature Storage amp Serving 9 2 9 Page 7 Thermostat Adjustment seessssssssssssssssssssssssssssssssssssssssssssssssssssssns Page 9 FE HR AFR AF FYR NAU RYDW YF Page 3 Electrical COMMECH um rear Page 3 Troubjeshootim AAA PR Page 14 8 Page 5 Cleaning the Cabinet e Defrosting Cleaning Condensor Coil e Door Gasket Maintenance didier Ten corintios rasta Page 17 POS sonados caian Page 9 tee er ere eer eer epee ee Page 22 Installation Use amp Maintenance 2 ww Receiving amp Inspecting Upon receiving your new Micro Matic Pro Line Wine dispenser check the package and the unit for any damages that may have occurred during transportation Visually inspect the exterior of the package If damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the packaging is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain all crating material until inspection has been made Finally contact Micro Matic Uncrating 1 Cut and remove the outer packaging 2 Lift the unit off the skid 3 If the unit has been laid down during this operation leave upright fo
14. gth of time the risk arises that the naturally occurring tartrates may drop out of solution and appear as sediment in the bottom of a wine glass Serving Pro Line Wine units are designed to maintain your wine keg temperature within the vintners recommended temperature serving range e White wines 45 F range 40 45 F e Red wines 55 F range 55 60 F IMPORTANT NOTICE The thermostats on the Pro Line Wine units have been factory preset at approximately 45 F for white wine dispensing and approximately 55 F for red wine dispensing Any change to the factory settings will affect performance of unit and void the warranty Factory testing has produced results that show consistent wine liguid temperatures are being maintained by the unit The Pro Line Wine unit operates like any refrigeration unit the compressor is engaged when the interior air temperature reaches the pre determined maximum level cooling the unit until it reaches the pre determined minimum level The goal is consistent wine liquid temperature inside the keg Thermostat displays are reading the air temperature setting and may be dramatically different than the keg liguid temperatures To verify measure the temperature of the wine dispensed in the glass 7 Installation Use amp Maintenance MICRO MATIC o MDD23W Air amp Wine Temperatures This chart shows that air temperature cycles but keg liguid temperature remains consistent Tempe
15. he C or F LED will blink 2 Release the keys then again push the SET keys for more than seven 7 seconds The L2 label will be displayed immediately followed by the Hy parameter NOW YOU ARE IN THE HIDDEN MENU 3 Select the required parameter 4 Press the SET key to display its number 5 Use the up or down arrows to change its number 6 Press the SET key store the new number and move to the following parameter To Exit Press the SET A or wait 15 seconds without pressing a key NOTE 1 If no parameter is present in L1 after three 3 seconds the nP message is displayed Keep the keys pushed until the L2 message is displayed NOTE 2 The set number is stored even when the procedure is exited by waiting for the time out to expire NOTE Any change in these parameters will effect unit performance and void warranty Installation Use amp Maintenance 10 en manic Parameters for MDD23W Thermostat SEN For Blue For Red Parameter Description i i meee msn wa Era nn EU 7777 I EA Y 6 O O a pacto der OO 47 a A A Ea 7777 i O N R nu mann a see 7 nenes 77 we ct xl EA 77777 O a amas Is we 11 www micromatic com 1 866 9 gero manic Parameters for MDD58W Thermostat Parameter Description Display Display me O NA WU HO mena reten e nemmen e o remm O OO O MAU Y I I oo Ou S Kd mmm ee Ma Y e EA ei OY I
16. oap and water Extreme stains or grease should be cleaned with a non abrasive cleaner and plastic scrub pad Stainless steel cleaners available which can restore and preserve the finish of the steel s protective layer e Never use an acid based cleaning solution Many food products have an acidic content which can deteriorate the finish these items include peppers tomatoes and other vegetables Be sure to clean ALL food products from any stainless steel surface Theinterior of the cabinet should be cleaned only with lukewarm water taking care not to scratch the galvanized metal surface Mild detergents are recommended Defrosting The unit will not reguire defrosting if the door is only opened for a minimum time Should ice form on evaporator turn unit off and allow to defrost Make sure the door closes properly and gasket seals completely as warm air entering the unit will cause evaporator to freeze and malfunction Do not use a pick knife etc to pry ice from evaporator as this could puncture evaporator or damage the coils 15 Installation Use amp Maintenance ww Cleaning Condenser Coil Clean the condenser coil every three months A dirty condenser will reduce the performance of the cooling system Do not block airflow to the perforated panel and do not operate the Pro Line Wine unit in environments above 100 F DANGER Power must be turned off and disconnected from the power source whenever
17. r 24 hours before plugging into power source MDD58W Series MDD23W Series 3 Installation Use amp Maintenance ego maric Location Be sure the location chosen has a floor strong enough to support the total weight of the unit and contents Recommended to use a professional installation company For the most efficient operation be sure to provide good air circulation around the unit MDD23W cannot be used for built in applications Avoid hot corners and locations near stoves and ovens It is recommended the unit be installed no closer than 2 from any wall The place for the dispenser must be open and free of dust and debris Installation Install Wine Font Sold Separately Place rubber washer over draft tower mounting holes in cabinet top Place wine line down through holes Secure font with four bolts provided Attach keg connectors to wine lines provided with wine font Install Keg Tapping Kit s Sold Separately Use only Wine Certified components for wine dispensing This includes grade 304 stainless steel or better and Barriermaster Flavourlock tubing Use of these components assures vintners guality Use John Guest swivel elbows to minimize line kinking Use zip ties to secure to gas line blue hose to John Guest fitting Installation Use amp Maintenance A ww Specifications 8 Dimensions MDD58W Series 8 5 TBD Condenser HP 3 3 Plug Type NEMA 5 15P 6
18. rature F 302 www micromatic com 1 866 327 4159 60 8 59 572 E 55 4 53 6 51 8 50 482 56 4 446 428 41 39 2 37 4 35 6 33 8 32 1 1 1 1 08 30 00 08 15 00 08 00 00 06 45 00 07 30 00 07 15 00 07 00 00 06 45 00 1 06 30 00 1 06 00 00 k Purple Thermocoupler in red wine keg Yellow Thermocoupler in white wine keg Red Temperature of the air in the red wine chamber 1 b Blue Temperature of the air in the white wine chamber tallatic n Use amp Maintenance ww Adjusting the Thermostat The Pro Line Wine dispenser is designed to maintain your wine keg temperature within the most desirable range of 45 to 55 F depending on the varietal You can expect the Pro Line unit to maintain temperature with the proper temperature control setting and in a normal environment If a different setting is desired follow these instructions to adjust the thermostat To display target set point Key Combination Operation in programming mode s emie it selects a parameter or confirms an operation p To lock or unlock the keyboard To start a manual defrost only XRO2CX To enter into In programming mode it programming mode browses the parameter codes or increases the displayed value In programming mode it browses the parameter codes or decreases the displayed value To return to room temperature display
19. t and compressor warranties are void if failure is due to improper electrical installation 13 Installation Use amp Maintenance ego maric Troubleshooting Sometimes working failures are due to simple causes which can be solved by the user Before asking for the help of a qualified technician you have to do some verifications These fail ures are not covered by the warranty 1 Refrigeration is not cooling a Check the unit is still connected to power supply 2 The thermostats on the Pro Line Wine units have been factory preset at approximately 45 F for white wine dispensing and 55 F for red wine dispensing Any change to the factory settings will affect performance of unit and void the warranty 3 After 24 hours refrigerated compartments do not reach temperature a Check temperature of dispensed wine b Check that the door gasket is clean and in good condition door is sealed c Check that the fan is operating www micromatic com 1 866 327 4159 14 ww Maintenance Cleaning the Cabinet Proper cleaning of stainless steel requires a soft cloth never use steel pads wire brushes or scrapers Cleaning solutions need to be alkaline or non chloride cleaners Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are also commonly found in hard water salts household and industrial cleaners e Routine cleaning of stainless steel can be done with s