NX-series Analog Output Unit

image

Contents

1. M A A B A B B 1 1 1 A1 B1 A1 Oy B1 2 2 2 2 C a2 OC B2 A2 B2 3 3 3 3 a3 O O Bs A3 B3 4 4 4 4 as OC B4 A4 B4 5 5 5 5 a5 OQ O Bs A5 B5 6 6l 6 6 as OQ Bs A6 B6 7 E27 7 7 a7 B7 a7 OO Bz 8 8 8 8 as OOQ B8 as OO Bs A B A B 12 mm width 12 mm width 8 terminal type 12 terminal type Symbol Name Function Temna numb r Terminal numbers for which A to D indicate the column and 1 to 8 indicate the line are displayed A ndicaions The terminal number is a combination of column and line so A1 to A8 and B1 to B8 are displayed The terminal number indications are the same regardless of the number of terminals on the terminal block B Release holes Insert a flat blade screwdriver into these holes to connect and remove the wires C Terminal holes The wires are inserted into these holes OMRON NX DA Applicable Wires Using Ferrules If you use ferrules attach the twisted wires to them Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules Always use one pin ferrules Do not use two pin ferrules The applicable ferrules wires and crimping tool are given in the following table Ferrule model Applicable wire eee Terminal ty
2. Connection to peripheral USB port on EtherCAT Coupler Unit NX Units End Cover OMRON CJ1W NCL181 _182 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products EtherCAT is a registered trademark of Beckhoff Automation GmbH for their patented technology Other company names and product names in this document are the trademarks or registered trademarks of their respective companies OMRON NX DA Ordering Information International Standards e The standards are abbreviated as follows U UL U1 UL Class Division 2 Products for Hazardous Locations C CSA UC cULus UC1 cULus Class Division 2 Products for Hazardous Locations CU CUL N NK L Lloyd CE EC Directives and KC KC Registration e Contact your OMRON representative for further details and applicable conditions for these standards Analog Output Unit Specification i NX Unit Unit Product Output setting Over all O i i ower Standards type Name Capacity Resolution e pei a E A 0to 100 25 mano 1 8000 4000 to 4000 9 3 250 us point Free Run 1 10W max NX DA2603 full scale refreshing Voltage oaa Switchin
3. connector NX bus I O power supply right I O power supply NX bus I O power supply I O power supply Installation orientation Possible in 6 orientations Restrictions No restrictions Terminal connection diagram Additional I O Power Supply Unit Voltage Output Unit NX DA3605 Voltage output Voltage output OMRON NX DA Current Output Unit 2points NX DA2203 Unit name Current Output Unit Model NX DA2203 Capacit 2 points External connection Screwless clamping terminal block 8 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance I O power supply method Free Run refreshing TS indicator Output range 4 to 20 mA DA2203 Output conversion 5 to 105 full scale as range Allowable load 600 Q min resistance Resolution 1 8000 full scale Overall 25 C 0 3 full scale accuracy 0 to 55 C 0 6 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs Deere etranath 510 VAC between isolated circuits for 1 g minute at a leakage current of 5 mA max Current capacity of I O IOV 0 1 A terminal max power supply terminal IOG 0 1 A terminal max 12 W x 100 H x71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Supply from the NX bus NX Unit power consumption 1 75 W max I O current c
4. no isolation between inputs Deere etranath 510 VAC between isolated circuits for 1 g minute at a leakage current of 5 mA max Current capacity of I O IOV 0 1 A terminal max power supply terminal IOG 0 1 A terminal max 12 W x 100 H x 71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Supply from the NX bus NX Unit power consumption 1 75 W max 1 O current consumption No consumption Weight Circuit layout 70 g max Output 11 to 12 Terminal block IOG connector left connector NX bus I O power supply right I O power supply NX bus I O power supply I O power supply Installation orientation and restrictions Installation orientation Possible in 6 orientations Restrictions For upright installation No restrictions For any installation other than upright Restricted as shown in the graph below Use it within this range Load resistance per point 40 55 C Ambient operating temperature Terminal connection diagram Additional I O Current Output Unit Power Supply Unit NX DA2205 Current output Current output OMRON NX DA Current Output Unit 4points NX DA3203 Unit name Current Output Unit Model NX DA3203 Capacit Pecinis External connection Screwless clamping terminal block 12 te p terminals terminals I O refreshing method Indicator Dimensions Insulation
5. resistance I O power supply method Free Run refreshing TS indicator Output range 4 to 20 mA DA3203 Output conversion 5 to 105 full scale as range Allowable load 350 Q min resistance Resolution 1 8000 full scale Overall 25 C 0 3 full scale accuracy 0 to 55 C 0 6 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs Deere etranath 510 VAC between isolated circuits for 1 g minute at a leakage current of 5 mA max Current capacity of I O IOV 0 1 A terminal max power supply terminal IOG 0 1 A terminal max 12 W x 100 H x 71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Supply from the NX bus NX Unit power consumption 1 80 W max I O current consumption No consumption Weight Circuit layout Installation orientation and restrictions 70 g max IOV Output 11 to 14 Terminal block IOG connector left connector NX bus I O power supply I O power supply right I O power supply 7 NX bus I O power supply Installation orientation Possible in 6 orientations Restrictions For upright installation No restrictions For any installation other than upright Restricted as shown in the graph below Use it within this range Load resistance per point 40 55 C Ambient operating temperature Terminal connection
6. 05 e 5 to 105 full scale 5 kQ min 0 5 Q max 1 30000 full scale Overall 0 1 full scale accuracy 0 to 55 C 0 3 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max Resolution Isolation method 12 W x 100 H x 71 D 20 MQ min between isolated circuits at 100 VDC Dielectric strength I O power supply method IOV 0 1 A terminal max IOG 0 1 A terminal max Current capacity of I O Supply from the NX bus power supply terminal NX Unit power consumption Weight Circuit layout Installation orientation and restrictions 1 10 W max I O current consumption No consumption 70 g max o i o Output V1 to V2 Q IOG ia I O power supply NX bus D connector I O power supply right Terminal block AG Analog circuit internal GND AG NX bus I O power supply left I O power supply Installation orientation Possible in 6 orientations Restrictions No restrictions Terminal connection diagram Additional I O Power Supply Unit Voltage Output Unit NX DA2605 Voltage output Voltage output OMRON NX DA Voltage Output Unit 4points NX DA3603 Unit name Voltage Output Unit Model NX DA3603 Capacit Avonts External connection Screwless clamping te
7. NX series Analog Output Unit NX DA Wide Lineup to Meet Various Analog Control Needs from High speed Synchronous Control to General Purpose CSM_NX DA_DS_E_1_1 e NX series Analog Output Unit e This unit can be used as an ECAT slave by connecting with the ECAT Coupler e Voltage and current output models are available Features e Output up to four analog signals with one Unit e Free run refreshing or I O synchronous refreshing can be selected for refreshing with the EtherCAT Coupler Unit e The lineup includes the model which achieves sampling speed of 10 us and resolution of 1 30000 ideal for high speed high precision control e The removable screwless terminal block improves maintenance e Screw less clamp terminal block significantly reduces wiring work e 12 mm wide unit can save space System Configuration Sysmac Studio Support Software EtherCAT master NJ series CPU Unit Connection to peripheral USB port J or built in EtherNet IP port on NJ series CPU Unit aL fa LZ Built in EtherCAT port Sysmac Studio ra EtherCAT Slave Terminal Support Software ications cable T7TTTTTTIT I potonar Commuricanens cabe No Sere 1 EtherCAT Coupler Unit I z Peripheral USB port l AE E NA i J i J MA
8. Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application requirements Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the Product may be changed without any notice When in doubt special part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2013 4 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Aut
9. T BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT S IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable
10. Voltage Output Unit NX DA3603 Voltage output Voltage output OMRON NX DA Voltage Output Unit 4points NX DA3605 Unit name Voltage Output Unit Model NX DA3605 Capacit Avonts External connection Screwless clamping terminal block 12 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance Switching Synchronous I O refreshing and Free Run refreshing 10 to 10 V TS indicator Output range Output conversion range DA3605 on 5 to 105 full scale Allowable load s 5 kQ min resistance 0 5 Q max 1 30000 full scale Overall 0 1 full scale accuracy 0 to 55 C 0 3 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max Output impedance Resolution 12 W x 100 H x 71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Dielectric strength I O power supply method IOV 0 1 A terminal max IOG 0 1 A terminal max Current capacity of I O Supply from the NX bus power supply terminal NX Unit power consumption Weight Circuit layout Installation orientation and restrictions 1 25 W max I O current consumption No consumption 70 g max IOV Output V1 to V4 Terminal block IOG connector left
11. diagram Additional I O Power Supply Unit Current Output Unit NX DA3203 Current output Current output OMRON NX DA Current Output Unit 4points NX DA3205 Unit name Current Output Unit Model NX DA3205 Capacit Ananie External connection Screwless clamping terminal block 12 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance I O power supply method Switching Synchronous I O refreshing and Free Run refreshing TS indicator Output range 4 to 20 mA DA3205 Output conversion 5 to 105 full scale ETS range Allowable load 350 Q min resistance Resolution 1 30000 full scale Overall 25 C 0 1 full scale accuracy 0 to 55 C 0 3 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs Deere etranath 510 VAC between isolated circuits for 1 g minute at a leakage current of 5 mA max Current capacity of I O IOV 0 1 A terminal max power supply terminal IOG 0 1 A terminal max 12 W x 100 H x 71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Supply from the NX bus NX Unit power consumption 1 80 W max I O current consumption No consumption Weight Circuit layout Installation orientation and restrictions Terminal connection diagram 70 g max IOV Output 11 to 14 Terminal block IOG c
12. g oints T 15000 to 0 1 e ee it 1 30000 15000 10 us point I O refreshing 1 10W max NX DA2605 EERIE and Free Run refreshing 1 8000 4000 to 4000 9 3 250 us point Free Run 1 25W max NX DA3603 full scale refreshing waa Switching points o Synchronous 1 30000 15000 to 20 We 10 us point I O refreshing 1 25W max NX DA3605 NX 15000 full scale and Free Run Series refreshing Analog To EF UC1 CE KC Output 1 8000 0 to 8000 ee 250 us point een 1 75W max NX DA2203 Unit full scale refreshing Current l Switching Output 2 points 04h Synchronous Unit 1 30000 O to 30000 pats 10 us point I O refreshing 1 75W max NX DA2205 alread and Free Run refreshing 1 8000 0 to 8000 40 3 oso us point Free Run 1 80W max full scale refreshing Switching 4 points ae Synchronous 1 30000 0 to 30000 rege 10 us point I O refreshing 1 80W max NX DA3205 ull Seale and Free Run refreshing Option Product Name Specification Model Standards i For 10 Units Cording Pins Terminal Block 30 pins Unit 30 pins NA ASANA E Accessories Not included OMRON NX DA General Specification Item Specification Enclosure Mounted in a panel Grounding method Ground to 100 or less Ambient operating temperature 0 to 55 C Ambient operating humidity 10 to 95 with no condensation or icing Atmosphere Must be free from corrosive gases Ambient storage temperature 25 to 70 C with no condensation or icing A
13. ground 0 08 to 1 5 mm terminals AWG28 to 16 SOLOMIN NNS 4 Conductor length stripping length OMRON NX DA Dimensions Unit mm Analog Output Unit NX DADOOO 12 mm Width 1 5 100 104 5 ooo d 1 5 Related Manuals Cat No aala Manual name Application Description number NX ADULULL NX series Analog I O Learning how to use NX series The hardware setup methods and functions of the NX W522 NX DALILILIL Dine Users cae Analog I O Units and series Analog I O Units and Temperature Input Units NX TSULULULI Temperature Input Units are described OMRON Terms and Conditions Agreement Read and understand this catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties a
14. ltitude 2 000 m max Pollution degree 2 or less Conforms to JIS B3502 and IEC 61131 2 seer Noise immunity 2 kV on power supply line Conforms to IEC61000 4 4 Overvoltage category Category Il Conforms to JIS B3502 and IEC 61131 2 EMC immunity level Zone B Conforms to IEC 60068 2 6 5 to 8 4 Hz with 3 5 mm amplitude 8 4 to 150 Hz acceleration of 9 8 m s 100 min each in X Y and Z directions 10 sweeps of 10 min each 100 min total Vibration resistance Shock resistance IConforms to IEC 60068 2 27 147 m s 3 times each in X Y and Z directions cULus Listed UL508 and ANSI ISA 12 12 01 AMEE oN eect Mek EC EN 61131 2 and C Tick KC Registration OMRON Analog Output Unit Specifications Voltage Output Unit 2points NX DA2603 Voltage Output Unit Unit name NX DA Model NX DA2603 Capacity I O refreshing method 2 points Free Run refreshing External connection Screwless clamping terminal block 8 terminals terminals Indicator TS indicator AD2603 mS Output range 10 to 10 V Output conversion 7 range 5 to 105 full scale Allowable load eran resistance Output impedance 0 5 Q max Resolution 1 8000 full scale Overall 25 C 0 3 full scale accuracy 0 to 55 C 0 5 full scale Conversion time 250 us point Dimensions Insulation resistance I O power supply method NX Unit power consumption Weight 12 W x 100 H
15. nd responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right c Buyer Remedy Omron s sole obligation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron com global or contact your Omron representative for published information Limitation on Liability Etc OMRON COMPANIES SHALL NO
16. omation Company http www ia omron com c Copyright OMRON Corporation 2013 All Right Reserved
17. onnector left connector NX bus I O power supply right I O power supply NX bus I O power supply I O power supply Installation orientation Possible in 6 orientations Restrictions For upright installation No restrictions For any installation other than upright Restricted as shown in the graph below Use it within this range Load resistance per point 40 55 C Ambient operating temperature Additional I O Current Output Unit Power Supply Unit NX DA3205 Current output Current output OMRON NX DA Version Information NX Series Analog Output Unit and Sysmac Studio Sysmac Studio Version 1 05 or lower Not supported NX Series Analog Output Unit 3 gt Version 1 06 or higher NX DAUULIL Supported External Interface Analog Output Unit NX DAOOHOL 12mm Width RN A RJ RY Re a ba A Symbol Name Function A NX bus connector This connector is used to connect each Unit B Indicators The indicators show the current operating status of the Unit The terminal block is used to connect external devices C Ferminali HOCK The number of terminals depends on the type of Unit Terminal Blocks
18. onsumption No consumption Weight Circuit layout Installation orientation and restrictions Terminal connection diagram 70 g max IOV o Output 11 to 12 O IOG AG Analog circuit internal GND AG EE NX bus I O power supply O I O power supply NX bus i _ fo _ Installation orientation Possible in 6 orientations Restrictions For upright installation No restrictions For any installation other than upright Restricted as shown in the graph below Terminal block Use it within this range Load resistance per point 40 55 C Ambient operating temperature Additional I O Power Supply Unit Current Output Unit NX DA2203 Current output Current output OMRON NX DA Current Output Unit 2points NX DA2205 Unit name Current Output Unit Model NX DA2205 Capacit 2 points External connection Screwless clamping terminal block 8 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance I O power supply method Switching Synchronous I O refreshing and Free Run refreshing TS indicator Output range 4 to 20 mA DA2205 Output conversion 5 to 105 full scale ETS range Allowable load 600 Q min resistance Resolution 1 30000 full scale Overall 25 C 0 1 full scale accuracy 0 to 55 C 0 3 full scale Between the input and the NX bus Power Transformer Signal Digital isolator
19. pes Manufacturer umber rime AWG ileal Sah Terminals other Phoenix Contact Al0 34 8 0 34 22 Phoenix Contact The figure in parentheses is the applicable wire size than ground Alo 5 8 0 5 20 CRIMPFOX 6 0 25 to 6 mm AWG24 to 10 terminals l Al0 5 10 ae Al0 75 8 0 75 18 Al0 75 10 Al1 0 8 1 0 18 Al1 0 10 Al1 5 8 1 5 16 Al1 5 10 Ground terminals Al2 5 10 Terminals other Weidmuller H0 14 12 0 14 26 Weidmuller The figure in parentheses is the applicable wire size than ground H0 25 12 0 25 24 PZ6 Roto 0 14 to 6 mm AWG 26 to 10 terminals 0 5 20 on 0 75 8 Ca 108 C ma A 15 HO Ca Some AWG 14 wires exceed 2 0 mm and cannot be used in the screwless clamping terminal block When you use any ferrules other than those in the above table crimp them to the twisted wires so that the following processed dimensions are achieved Finished Dimensions of Ferrules a mm 1 6 mm max except ground terminals Pha mm max except ground terminals 2 0 mm max ground terminals 2 7 mm max ground terminals Using Twisted Wires Solid Wires If you use the twisted wires or the solid wires the applicable wire range and conductor length stripping length are as follows Use the twisted wires to connect the ground wire to a ground of 100 Q or less Do not use the solid wires Terminal types Applicable wires Conductor length stripping length Ground terminals 9 to 10 mm Terminals other than
20. rminal block 12 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance Free Run refreshing TS indicator Output range 10 to 10 V Output conversion range AD3603 ae 5 to 105 full scale Allowable load s 5 kQ min resistance 0 5 Q max 1 8000 full scale Overall 0 3 full scale accuracy 0 to 55 C 0 5 full scale Between the input and the NX bus Power Transformer Signal Digital isolator no isolation between inputs 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max Output impedance Resolution 12 W x 100 H x 71 D Isolation method 20 MQ min between isolated circuits at 100 VDC Dielectric strength I O power supply method IOV 0 1 A terminal max IOG 0 1 A terminal max Current capacity of I O Supply from the NX bus power supply terminal NX Unit power consumption Weight Circuit layout 1 25 W max I O current consumption No consumption 70 g max IOV Output V1 to V4 Terminal block IOG connector left connector NX bus I O power supply I O power supply right I O power supply NX bus I O power supply Installation orientation and restrictions Installation orientation Possible in 6 orientations Restrictions No restrictions Terminal connection diagram Additional O Power Supply Unit
21. x 71 D Between the input and the NX bus Power Isolation method Transformer Signal Digital isolator no isolation between inputs 20 MQ min between isolated circuits at Dielectric strenath 510 VAC between isolated circuits for 1 100 VDC g minute at a leakage current of 5 mA max Current capacity of I O IOV 0 1 A terminal max UEP yearn Ny eus power supply terminal lOG 0 1 A terminal max 1 10 W max 1 O current consumption No consumption 70 g max Circuit layout connector NX bus I O power supply left I O power supply Output V1 to V2 Terminal block IOG connector I O power supply NX bus right I O power supply Installation orientation and restrictions Terminal connection diagram Installation orientation Possible in 6 orientations Restrictions No restrictions Additional I O Power Supply Unit Voltage Output Unit NX DA2603 Voltage output Voltage output OMRON NX DA Voltage Output Unit 2points NX DA2605 Unit name Voltage Output Unit Model NX DA2605 Capacit 2 points External connection Screwless clamping terminal block 8 pasty p terminals terminals I O refreshing method Indicator Dimensions Insulation resistance Switching Synchronous I O refreshing and Free Run refreshing Output range Output conversion range Allowable load resistance Output impedance 10 to 10 V TS indicator DA26