Home

Mise en page 1 - Pdfstream.manualsonline.com

image

Contents

1. POWERED OFF by pressing the two POWER keys simultaneously at any time User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 7 AMPLIFIER CONTROLS POWER The MIMESIS 330 Analog Integrated Amplifier is powered on using the switch located on the back panel In regular use this switch should be left ON at all times See Sound Quality Optimization The standby function of the remote control should be used to mute the signal for the safe removal of cabbles The Amplifier is powered OFF by switching the back panel switch to the OFF position A saftey circuit switches the unit to mute to avoid any diusturbance reaching the speakers MUTING Muting is controlled using the remote control It can be used to turn the volume down temporarily without touching or changing the volume control When returned to normal the volume is returned to its level at the point the muting was activated VOLUME Volume may be adjusted manually by turning the volume control knob or by using the VOLUME or on the remote control SELECTOR Selects one of the eight if the D A option is selected five if not available inputs for listening One step clockwise selects the next input Selection may also be made using the remote by pressing the key corresponding to the input on the Analog section of the remote OPENING VOLUME MEMORY This function is only accessible via the remote control It allows the volume to be automatically set to the le
2. width and computer linking which are a necessity for accurate transcription of analog messages for todays best complete systems Only careful installation and use can provide the satisfaction you are expecting The installation instructions must be carried out in full and the mentioned precautions taken to get the expected result and to avoid impairing the amplifier s performance User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER CONTENTS 1 UNPACKING 2 CHOICE OF AMPLIFIER LOCATION AND COOLING 3 LINE VOLTAGE ADJUSTMENT 4 CONNECTIONS 5 AMPLIFIER CONTROLS 6 SOUND QUALITY OPTIMIZATION 7 MAINTENANCE 8 TECHNICAL DATA p4 p4 p5 p6 p7 8 p9 p9 p 10 11 User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER UNPACKING THE MIMESIS 330 ANALOG INTEGRATED AMPLIFIER You will find in the GOLDMUND mimesis 330 box I The amplifier amp power cord I The remote control I This manual Please keep the packaging in case you need to transport the amplifier at a later date WARNING IF YOU NEED TO RETURN THE MIMESIS 330 TO THE FACTORY OR TO YOUR LOCAL REPRESENTATIVE FOR A WARRANTY REPAIR PLEASE NOTE THAT IT MUST BE REPACKED IN THE ORIGINAL PACKAGING THIS PACKAGING HAS BEEN DESIGNED SPECIFICALLY TO PROTECT YOUR MIMESIS 330 IN TRANSIT USE OF ALTERNATIVE PACKAGING IS LIKELY TO RESULT IN DAMAGE INVALIDATING WARRANTY COVER CHOICE OF AMPLIFIER LOCATION AND COOLING The GOLDM
3. IZE AND WEIGHT 44 cm 17 3 W x 38 cm 15 D x 10 cm 4 H e Weight 14 kg net WARRANTY e 3 years parts and labor User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 11
4. UND MIMESIS 330 amplifier as all high quality amplifiers generates a large amount of heat when driven at high levels and must be vented properly It is mandatory to allow a proper cooling of the heat sinks Do not put temperature sensitive equipment on top of the amplifier User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 4 LINE VOLTAGE ADJUSTMENT A voltage selector is provided on the backplate of the amplifier If your line voltage is not adapted to the voltage indicated on the serial plate of the amplifier please consult your local GOLDMUND dealer for internal adjustment ATTENTION On the 220V position the GOLDMUND mimesis 330 amplifier will function properly for main line voltage between 190V and 245V On the 110V position the main line must deliver between 95 and 125V If your main line is usually out of these tolerances please consult your GOLDMUND dealer Please check the value of the main line fuse This fuse is located on the back panel of the amplifier above the two power cord receptacles Use a 5A delayed fuse for 220V and an 8A delayed fuse for 110V User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 5 CONNECTIONS Connect the power cord to the back of the amplifier and plug it into the nearest wall plug Use only a 3 lugs grounded plug for safety reasons To get the best sound from the ampli fier avoid any multiple plug or extension cord Connect the speaker c
5. USER MANUAL GOLDMUND MIMESIS 330 Analog Integrated Amplifier Congratulations Thank you for purchasing the GOLDMUND MIMESIS 330 You have acquired the best Analog Integrated Amplifier ever made for professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleas ure of listening to the MIMESIS 330 even higher INTRODUCTION The GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER Goldmund was founded in 1978 and has ever since been dedicated to the accurate reproduction of sound and image At Goldmund we strive to lead in the creation development and manufacture of the industry s most advanced technologies including audio and video systems home networking and music distribution The guiding principle at Goldmund is to produce a precise sound with the least possible loss of quality through the different stages Goldmund will never adopt a technology before it is sufficiently developed to satisfy the high quality standards we set This is why Goldmund has often rejected mainstream technologies and developed its own User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER No connection or manipulation must be done before reading those instructions Damage of the amplifier may result if the following instructions are not consciously understood and applied This high quality amplifier possesses new technical features such as ultra high band
6. ables to the 5 way binding posts on the back panel Connect the interconnects from the analog source devices to the line inputs numbered 1 to 5 For the D A option connect the interconnects from the analog source devices to the line inputs numbered 6 to 8 ATTENTION A residual High Frequency noise may remain audible in some circumstances if an input is left open and is selected This disturbance has no effect on the Amplifier but may be easily avoided with the application of short circuiting plugs on all unused inputs User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 6 AMPLIFIER CONTROLS Manual Operation On the front plate of the GOLDMUND MIMESIS 330 amplifier you will find only two POWER keys In the Manual Operation mode the two POWER keys have to be activated simultaneously to power the amp on This security feature is provided to avoid accidental POWER ON or POWER OFF When the two keys are pressed simultaneously the amp switches on in Operating mode and the center green Led lights on showing the amp is POWERED ON If the digital input is used the yellow Led may flicker showing there is no lock and the amp remains muted until a lock is found With an analog input the amp is immediately operational By pressing the right key once the amplifier is put in Mute mode and the green Led flickers By pressing the right key once again the amplifier returns to Operating state The amp may be
7. nce 50 kOhms GROUP DELAY Propagation delay lt Ims stable with frequency from DC to 100 kHz DISTORTION Figures valid for all levels from 0 to 25 V 8 Ohms Dynamic TID lt 0 003 80 dB Static THD lt 0 003 80 dB SPEED e Slew rate gt 30 V us Rise time lt 500 ns POWER SUPPLY Nominal line voltage 117 234 V switchable Input voltage range 10 Maximum power consumption 700 W NOISE e Signal to noise ratio gt 90 dB e Weighted ASA A gt 100 dB OPERATING TEMPERATURE Room temperature 30 to 40 degrees Celsius 22 to 104 degrees Fahrenheit Internal temperature 45 to 65 degrees Celsius 113 to 149 degrees Fahrenheit User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 10 TECHNICAL DATA e Separated ground and earth Floating chassis connected to mains earth e Possible link for optionally connecting both CROSSTALK Separation gt 90dB between channels PRODUCT SPECIFIC SAFETY FEATURES Automatic switching to MUTE if the AC line drops or is interrupted FRONT PANEL CONTROLS Volume control e Selector input switch REAR PANEL CONNECTORS AND CONTROLS e Power cord universal socket 3 lugs e Main fuse 5A slow blow 110V 8A slow blow 220V e Green yellow AC earth binding post e Speaker 5 ways binding posts left and right Voltage selector 110 220V Inout connector RCA right and left for line inputs S
8. vel fixed when the unit is turned ON To adjust the level first play at the desired output level then press MEMO on the remote If at any time during playback you wish to return to this level just press the RESET button User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER IP 8 SOUND QUALITY OPTIMIZATION Warm up Sonic Effect If the amplifier has been powered OFF for some time the optimum sound quality is only reached after some time It may take 15 minutes for the amplifier to reach optimum operating temparature as the circuits have to warm up to around 55 degrees Celsius 131 degress Farenheit MAINTENANCE The GOLDMUND MIMESIS 330 amplifier usually requires no maintenance Always turn the power OFF before cleaning your amplifier Use a clean soft damp cloth to clean the amplifier surface Dampen the cloth with water or a mild detergent solution Avoid abrasive or harsh cleansers eg products containing sodium carbonate User manual GOLDMUND MIMESIS 330 ANALOG INTEGRATED AMPLIFIER P 9 TECHNICAL DATA POWER Nominal power 165 W RMS 8 Ohms 330W Total e Maximum instantaneous power before clipping 250 W per channel FREQUENCY RESPONSE These figures are valid for the circuit alone at any level between 0 and nominal power e 0 1 dB 0 50 kHz 1 dB 0 150 kHz e 3 dB 0 300 kHz INPUT SENSITIVITY e Nominal level 1 V RMS e Nominal input impeda

Download Pdf Manuals

image

Related Search

Related Contents

Viessmann Gebrauchsanleitung Manual Mode d`emploi  Osram 549167 energy-saving lamp    manual de instalação  本書の見かた  Vehicle and Repair Template  DishTV T1020 The Full user Manual can be downloaded at www  Nos déchets : MODE D`EMPLOI - Mairie de Saint-Parize-Le  3100B ventilator  

Copyright © All rights reserved.
Failed to retrieve file