Home

General Test Equipment - Koehler Instrument Co., Inc.

image

Contents

1. based software which comes standard with the unit Carbon Residue on 10 Distillation Residue As per section 10 ASTM D189 the procedure for carbon residue of light distillate oils can be performed Included Accessories Distillation Flask 125mL with Markings Ceran Plate 25mm dia hole Ceran Plate 38mm dia hole Ceran Plate 50mm dia hole 3 Point Calibrated PT100 Thermometer with Cable and Plug special Graduated Receiver Cylinder with Base Wiper for Condenser Tube Dropping Plate Teflon Plug for 125mL Flask silicone Plug for Flask Side Arm Dry Point Detection Board Windows based Automatic Distillation Software 97 K45703 TS Automatic Distillation Analyzer with Touch Screen Display and Integrated PC Ordering Information Automatic Distillation Analyzer 5000 Series Catalog No K45603 K45604 K45703 TS K45704 TS K45634 K45635 K45655 K45656 K45657 K45656 A K45650 K45651 E K45651 B K45601 03014 K45668 K45654 A K45652 C K45694 Automatic Distillation Analyzer 120V 60Hz Automatic Distillation Analyzer 230V 50 60Hz Automatic Distillation Analyzer with Touch Screen Display and Integrated PC 120V 60Hz Automatic Distillation Analyzer with Touch Screen Display and Integrated PC 230V 50 60Hz Accessories Distillation Flask 125mL with Markings PTFE Centering Stopper for 125mL Flask Ceran Plate 32mm dia hole Ceran Plate 38mm dia hole Ceran Plate 50mm dia hole Ceran Plate 25mm dia hol
2. Ordering Information receiving traps Catalog No K31820 Mounting Equipment K31830 Dean amp Stark Apparatus Consists of stand and connecting hardware GENERAL PURPOSE HEATER Utility Heater e For general laboratory applications e Precise reproducible settings e 1000W or 1250W nichrome heater option e Accepts flat bottom and round bottom beakers and flasks Variable control electric heater designed for efficient reproducible heating of flat bottom and round bottom beakers and flasks Electronic unit control with reference dial permits fine temperature adjustment and accurate repeatable settings Includes porcelain refractory heater with nichrome element 1000W or 1250W and refractory support plate that reverses to accept different size beakers and flasks Polished stainless steel housing has cooling vents and two dovetail clamps to accommodate accessory support rod Line switch and 6ft 1 8m three conductor line cord and plug are included Electrical Requirements C 115V 60Hz 220 240V 50 60Hz Dimensions xwxh in cm Shipping Information OXOX10 12 7x12 7x25 4 shipping Weight 8 Ibs 3 6 kg Net Weight 4 Ibs 2 0kg Dimensions 1 5 Cu ft Ordering Information Catalog No K42000 Utility Heater 115V 60Hz 1000W K42001 Utility Heater 115V 60Hz 1250W K42090 Utility Heater 230V 50 60Hz 1000W K42091 Utility Heater 230V 50 60Hz 1250W K42000 General Purpose Utility Heater 72 REFRACTIVE INDEX OF PETROLEUM
3. 5 to 200 C 0 8 C 200 to 315 C sample size 5 mg approximately sample Holder Glass Slide lt 1mm 0 02mm thick sample Cover Glass Coverslip 0 17mm thick Temperature Sensor Pt 100 2 wire RTD Test Storage Up to 20 tests with parameters Electrical Requirements 115V 60Hz Single Phase 220V 50Hz Single Phase GEOG INSTRUMENT Niet INC GENERAL PURPOSE BATHS Constant Temperature Water Baths e Accurate Microprocessor Control e Three User defined Temperature Preset Buttons e Redundant Safety Backup e Front Panel Lockout e Electronic Calibration Economical constant temperature water baths offer superior temperature control range and uniformity Bath fluids can be controlled at temperatures as high as 100 C 60 C without cover with 0 1 C precision and 0 2 C uniformity Bath temperature is displayed continuously on a bright easy to read LED panel in your choice of C or F Set point temperature is recalled with just the touch of a button Three user defined temperature preset buttons allow for quick selection of often used temperature set points Dual thermostats provide optimum protection for your work and water bath The high limit alarm alerts you if bath temperature exceeds your pre set limit A secondary Safety Set thermostat guards against thermal runaway automatically disconnecting heater power should bath temperature get too high or the liquid level drop too low K33056 General Purpose
4. C or F Pressure Flow Rate Programmable Model 30 Ipm max 60 Hz 22 lpm max 50 Hz standard Model 2 speed 9 or 15 Ipm suction Flow Rate Programmable Model 22 Ipm max 60 Hz 15 Ipm max 50 Hz standard Model N A e Available in Three Different Capacities 6 13 and 28 Liter Heater S AO RESENO Openg _ Programmable Model 1100 Watts 60 Hz e Microprocessor temperature control with C F digital temperature set 2200 Watts 50 Hz and display Standard Model 1100 Watts 60 Hz e Adjustable Over Temperature protection and Low Liquid Cutoff 1600 Watts 50 Hz Ordering Information Catalog No Model Capacity Electrical Requirements Overall Dimensions Working Access Shipping Weight CE LxWxH LxWxD K33062 Standard 6L 1 6 gal 120V 50 60Hz 14 25x8 25x8 14 in 6 25X5 25X5 51N 24 Ibs K33063 240V 50 60Hz 37 9X21X35 6 cm 13 3x13 3x14 cm 11 kg K33064 Programmable 6L 1 6 gal 120V 50 60Hz 14 25x8 25x8 14 in 3299 2I N 30 Ibs K33065 240V 50 60Hz 37 5x21x35 6 cm 13 3x13 3x14 cm 14 kg K33066 Standard 13L 3 4 gal 120V 50 60Hz 15 5x10 88x14 75 in 0 20X0 9X oN 31 Ibs K33067 240V 50 60Hz 39 4x27 6x37 5 cm 13 3x21 6x19 7 cm 14 kg K33068 Programmable 13L 3 4 gal 120V 50 60Hz 15 5x10 88x14 75 in 5 25X8 9X1 ro iN 40 Ibs K33069 240V 50 60Hz 39 4x27 6x37 5 cm 13 3x21 6x19 7 cm 18 kg K33070 Standard 28L 7 3 gal 120V 50 60Hz 22 15X13 19x14 75 in 12 13x10 38x8 in 42 Ibs K33071 240V 50 60Hz 55 8X33 5X3 7 5 CM 30 8x26 4x120 3 cm
5. 115V 60Hz KLA 6 220 Automatic Filter Plugging Tendency Analyzer FPT 220 240V 50 60Hz Accessories KLA 1820 8013 Glass Fibre Filters pk of 100 KLA PT100 CAL Calibration Box and Cables KLA DB KIT Kit of Connectors and Cables for Cold range OXIDATION STABILITY OF FOODS OILS Test Method For the determination of the oxidation stability of samples solid semi solid or liquid in order to determine product quality and obtain value added information related to the fat oxidation processed in samples of foods oils fats and Biodiesel Fuels Oxidation Test Reactor The Oxidation Test Reactor is a versatile instrument suitable for a wide range of oxidation stability and shelf life applications including e Prediction of the oxidation stability during shelf life studies by analyzing the product at defined time intervals and building an experimental curve e Evaluation of the adequacy of storage conditions e Evaluation of an optimal packaging solution e Comparison of the oxidation stability of different formulas for food preparations e Evaluation of the oxidative stability of vegetable oils of different botanical origin e Evaluation of the effectiveness of antioxidants e Information on product oxidation when the oxidation flex is not visible especially for products with a low fat content 4 5 In this case product oxidation can be achieved by combining the Oxidation Test Reactor with the gas chromatographic technique The Oxi
6. AUTOMATIC FILTER PLUGGING TENDENCY ANALYZER FPT Test Method Determines the Filter Plugging Tendency FPT of distillate fuel oils where the end use demands an exceptional degree of cleanliness This test is applicable to fuels within the viscosity range of 1 50 to 6 00 mm2 s cSt at 40 C The test is not applicable to fuels that are not clear and bright because water interferes with the measurement of filter plugging Causes of poor filterability might include fuel degradation products contaminants picked up during storage or transfer or interaction of the fuel with the filter media Any of these could correlate with orifice or filter system plugging or both Automatic Filter Plugging Tendency Analyzer e integrated Cooling System equipped with a single stage gas motor compressor CFC free Measuring device complete with support for filter Beakers PT100 sensor Class A level sensor pressure gauge tubes and joints Pump 20 mL min 6 4 TFT LCD built in touch screen panel PC for the managing of the analyzer by means of Lab Link Software USB connection to an external printer or external PC Storage capacity for more than 60 000 analysis Specifications Conforms to the specifications of ASTM D2068 IP 387 Electrical Requirements C 115V 60Hz 220 240V 50 60Hz KLA 6 Automatic Filter Plugging Tendency Analyzer FPT Ordering Information 76 Catalog No KLA 6 Automatic Filter Plugging Tendency Analyzer FPT
7. Standard to perform the dry point analysis Simply order the Automatic Dry Point Detection Kit for Solvents see Ordering Information at right which includes dry point thermocouple 200mL flask and PTFE plug to perform dry point detection analysis automatically Ready for Groups 1 4 and more Each Koehler Automatic Distillation Analyzer 5000 Series comes ready with the equipment accessories and features as standard to properly run distillation groups 1 to 4 per ASTM D86 and related test specifications No additional accessories are required The Windows based software package allows simple operator selection of the programmed settings for each distillation protocol No complicated routines are needed to set up the unit User defined programs are easily created for customization of the analyzer Calculated Cetane Index Calculated cetane index is a useful tool for estimating ASTM D4737 cetane number where a test engine is not available for determining this properly It may be conveniently employed for approximating cetane number where the quantity of sample is too small for an engine rating In cases where the cetane number of a fuel has been initially established the index is useful as a cetane number check on subsequent Samples of that fuel provided its source and mode of manufacture remain unchanged The Cetane index is automatically calculated at the end of the test if all the necessary variables are entered and is a component of the Windows
8. temperature control gives reproducible results to within 1 The unit contains an automatic temperature safety cut off feature if no melting points are detected 15 C above the expected melting point or if the oven reaches 315 C The melting process is magnified recorded and viewed on screen in real time by a CCD camera The change in physical appearance of the sample with respect to temperature is recorded and the start end of melting is observed automatically A representation of the entire process can be printed out in graphical form for validation Dimensions Ixwxh in cm Main Unit 161x12x13 42x31x33 Monitor 8x54x5 20x14x14 Net Weight Main Unit 22 Ibs 10 kg Monitor 1 8 Ibs 0 8 kg Ordering Information Shipping Information Weight 29 Ibs 13 kg Dimensions 3 6 Cu ft Catalog No Order Qty K90100 Automatic Melting Point Range Apparatus 115V 60Hz 1 K90190 Automatic Melting Point Range Apparatus 220V 50Hz Accessories K90100 1 Glass slides pack of 500 K90100 2 Cover slips pack of 1000 K90100 3 Sampling jig 69 K90190 Automatic Melting Point Range Apparatus Specifications Conforms to the specifications of BP Appendix 5 Method 6 GLP Visual Image 10x magnified displayed on monitor Temperature Range ambient 5 to 315 C Heating Rates 0 2 0 5 1 0 2 0 3 0 6 0 12 0 C min Temperature Readability 0 1 C Cooling Time 20 minutes 300 C to ambient Temperature Accuracy 0 5 C ambient
9. 60Hz with Finger Tube RA Accessories K60002 LT 1 Rotor Assembly for Long Tubes K60092 K60002 ST K60092 ST K60002 PT K60092 PT K60002 FT K60092 FT Rotor Assembly K61101 Centrifuge Tube Long 100mL 8 marked in mL ASTM D91 D96 D893 D1796 D4007 K61106 Centrifuge Tube Long 100mL 8 marked in 200 parts ASTM D96 K61110 Centrifuge Tube Long 100mL 8 marked in mL every 1mL above 10mi ASTM D96 D4007 K61112 Centrifuge Tube Long 100mL 8 marked in 200 parts every 2 parts above 20 parts ASTM D96 K61109 Centrifuge Tube Cone Shaped 100mL with capillary tip capable of measuring 0 01 mL and readable by estimation to 0 005 ASTM D2273 D2709 K61153 cushion required for each tube K61153 PTFE cushion for Long Tubes w capillary tip Req for K61109 tubes K60002 ST 1 Rotor Assembly for Short Tubes K61102 Centrifuge Tube Short 100mL 6 marked in 200 parts every 4 parts above 20mL ASTM D96 K61105 Centrifuge Tube Short 100mL 6 marked in mL ASTM D96 K61107 Centrifuge Tube Short 100mL 6 marked in mL every 2mL above 10mL ASTM D96 K61108 Centrifuge Tube Short 100mL 6 marked in 200 parts ASTM D96 K60002 PT 1 Rotor Assembly for Pear Tubes K61104 Centrifuge Tube Pear 100mL marked in mL ASTM D1966 K61152 Centrifuge Tube Pear 100mL with tube tip having graduations of 0 01mL over the range 0 to 0 2mL ASTM D2709 K61111 Cork Stopper for Centrifuge Tubes K60002 FT 1 Roto
10. ASTM D96 API 2542 IP MPMS CHAPTER 10 4 ou cece 63 Ash from Petroleum Products 0 0 cccccccscessssesessscsseseesereeens 63 Automatic Density Meter ASTM D1250 D4052 D5002 DIN 51757 oo cecccsecssesseestetseeenes 64 Rust Protection by Metal Preservatives in the Humidity Cabinet ASIM D1748 FIM 7915310 serenana 65 Sampling of Petroleum and Petroleum Products ASTM D4057 D1265 D6074 GPA 2140 sccccreen 66 67 Sampling Liquefied Petroleum LP Gases ASTM D1265 and GPA 2140 eerren 66 67 Freezing Point of Aqueous Engine Coolant Solution ASTM D1177 68 Color of Maleic and Phthalic Anhydrides ASTM D3366 00 68 Automatic Melting Point Range Apparatus BP Appendix 5 Method 6 GLP 69 General Purpose Baths 0 0c ccc cceescseseesecesecsesecsssecssseeeees 70 71 Water in Petroleum Products and Bituminous Materials by Distillation ASTM D95 E123 D244 D370 AASHTO T55 T59 API MPMS CH 10 5 IP 74 291 FIM 791 3001 ISO 3733 ccenn 72 General Purpose Utility Heater cc ceeceescseseeseteeseeesees 72 Refractive Index and Refractive Dispersion of Hydrocarbon Liquids ASTM D1218 DIZAT oo ccccccccsccescesessesessessssessssesssessesessesensevsssessssessnsens 73 Calibration of Liquid in Glass Thermometers NBS Monograph 150 74 pH Conductivity Meters 0c ccccccesccscssescseseeecsssesecssseteeesseeaes 74 Automatic Titrator ASTM D664 D2896 D3227 D4739 oo eee 75 Automatic Calo
11. Information Catalog No Order Qty K27100 Ramsbottom Carbon Residue Apparatus 115V 60Hz 1 K27190 Ramsbottom Carbon Residue Apparatus 220 240V 50 60Hz Accessories 332 007 001 Coking Bulb 5 Borosilicate Glass with capillary Conforms to ASTM D524 specifications 362 010 001 Sample Charging Syringe 1 382 018 001 Needle 18 gauge 2 1 K27320 Coking Bulb Filling Device 1 Convenient time saving device fills up to five coking bulbs at a time Ideal for viscous fluids that are difficult to handle at room temperature K27200 Control Bulb 1 Stainless steel with IC thermocouple May be used with a thermocouple pyrometer to verify compliance of the furnace with ASTM performance requirements K29310 Digital Thermometer 115V K29319 Digital Thermometer 220 240V The K29310 Digital Thermometer is suitable for this purpose 09 Specifications Conforms to the specifications of ASTM D524 D6074 IP 14 ISO 4262 FIM 791 5002 NF T 60 117 Furnace Type Cast iron block Capacity 5 coking bulbs Maximum Temperature 650 C 1200 F Controller Sensitivity 1 C 2 F Heater 0 2400W ceramic band heater Electrical Requirements 115V 60Hz Single Phase 20 8A 220 240V 50 60Hz Single Phase 10 9A Dimensions xwxh in cm 16xX21 x14 41x95x37 Net Weight 64 Ibs 29kg Shipping Information shipping Weight 78 Ibs 35kg Dimensions 8 2 Cu ft Software compatible inquire with Koehler Customer Service Ke
12. PRODUCTS Test Method Refractive index is a fundamental physical property that is used in conjunction with other properties to characterize pure hydrocarbons and their mixtures It is a useful property for concentration measurements purity determinations and chemical identification Automatic Petroleum Refractometer e Conforms to ASTM D1218 D1747 and D5006 test specifications e Electronic heating and cooling Peltier system eliminates the need for a circulating water bath Automated and precise refractive index measurements Rugged sapphire prism Designed for samples ranging from clear to highly colored dark and opaque Clear graphical LCD display with on screen instructions and full menu operation e Multipoint calibration routines maximize accuracy e RS232C and centronics communication ports The Koehler Automatic Refractometer uses precision optics and superior image analysis to extend the repeatability and accuracy of refractive index measurements for petroleum products Subjectivity is removed from tests results because no manual activities such as aligning shadowlines or reading analog scales are necessary Opaque hydrocarbons present no problem for this unit which uses reflected light measurement technology as opposed to manual refractometers which are of the transmission type The dual temperature control system and flat easy clean sample area make the instrument ideal for viscous or sticky samples Two models are available M
13. Water Bath 10L The Constant Temperature Water Baths are also designed for operating convenience The steeply gabled polycarbonate cover accommodates glassware of varying heights and tilts out of your way when loading or removing samples allowing condensate to drain neatly back into the bath Specifications Temperature Control 0 1 C setpoint and C F switchable LED display Temperature Stability 0 2 C Temperature Range Ambient to 100 C with cover Ambient to 60 C without cover Ordering Information Catalog No Capacity Electrical Requirements Overall Dimensions Opening Dimensions Shipping Weight CE LxWxH LxWxH K33050 2L 0 5 gal 120V 50 60Hz 2 5A 8 94x7 90x8 13 in 5 31xX5 88x5 81 in 11 Ibs K33051 240V 50 60Hz 1 25A 22 11X20 07x20 65 cm 13 49x14 94x14 76 cm 4 99 kg K33052 2L shallow 120V 50 60Hz 2 5A 9 44x13 65x8 13 in 5 81X11 69x2 50 in 12 Ibs K33053 0 5 gal 240V 50 60Hz 1 25A 23 98x34 67x20 65 cm 14 76x29 69x6 35 cm 5 44 kg K33054 5L 1 3 gal 120V 50 60Hz 4 2A 9 44x13 65x8 13 in 5 94x11 75x5 94 in 15 Ibs K33055 240V 50 60Hz 2 1A 23 98x34 67x20 65 cm 15 09x29 85x15 09 cm 6 80 kg K33056 10L 2 6 gal 120V 50 60Hz 4 2A 15 43x14 90x8 13 in 11 69x12 75x5 94 in 23 Ibs K33057 240V 50 60Hz 2 1A 39 19x37 85x20 65 cm 29 69x32 39x15 09 cm 10 43 kg K33058 20L 5 2 gal 120V 50 60HZz 8 3A 15 19x21 65x8 13 in 11 50x19 50x5 88 in 30 Ibs K33059 240V 50 60Hz 4 15A 38 58x54 99x20 65 cm 29 21x49 53x14 94 cm 13 61 kg K330
14. a T valve 1 729 liquid semi liquid or solid state whose vapor pressure at ambient conditions iS Max height 21 below 101kPa crude oil etc Max length 4 7 Ordering Information Max width 4 2 Catalog No K28100 Core Type Sampling Thief Keale INSTRUMENT COMPANY INC 67 FREEZING POINT OF AQUEOUS ENGINE COOLANT SOLUTION Test Method Determines the freezing point of aqueous engine coolant solutions by cooling a sample with continuous agitation until a plateau is observed in a time temperature curve Freezing Point Apparatus e Conforms to ASTM D1177 specifications Determines freezing points of aqueous engine coolants Includes 200mL freezing tube with drilled cork outer flask motorized stirrer clamps and Stand Similar to K29700 Freezing Point Apparatus Electrical Requirements C 115V 60Hz 220 240V 50Hz 220 240V 60Hz Ordering Information Catalog No Order Qty K29750 Freezing Point Apparatus 115V 60Hz 1 K29758 Freezing Point Apparatus 220 240V 50Hz K29759 Freezing Point Apparatus 220 240V 60Hz 290 000 75F ASTM 75F Thermometer Range 35 to 35 F 1 250 000 76F ASTM 76F Thermometer Range 65 to 5 F For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 COLOR OF MALEIC AND PHTHALIC ANHYDRIDES Test Method Molten samples of maleic or phthalic anhydride are compared with Platinum Cobalt color standards for determining sample
15. and construction to the standard Front View Distillation Apparatus but equipped with a 300W copper immersion condenser heater with stepless electronic control Available with right or left hand heater unit Note The Group 4 Apparatus can also run distillations for petroleum products categorized as Groups 1 2 and 3 Included Accessories Flask Support Boards A and C Graduate Cylinder Support Block Shipping Information shipping Weight 65 Ibs 29 5kg Dimensions 13 3 Cu ft Specifications Conforms to the specifications of ASTM D86 D216 D233 D447 D850 D1078 E133 IP 123 195 ISO 3405 DIN 51751 FTM 791 1001 791 1015 NF M 07 002 Electrical Requirements C 115V 60Hz Dimensions Ixwxh in cm 220 240V 50 60Hz 15x18x19 39x46x50 ASTM Distillation Thermometers Catalog No Thermometer Range 250 000 020 ASTM 2C Partial Immersion 5 to 300 C 250 000 07F ASTM 7F Low Distillation 30 to 580 F 250 000 07C ASTM 7C Low Distillation 2 to 300 C 250 000 08F ASTM 8F High Distillation 30 to 760 F 250 000 08C ASTM 8C High Distillation 2 to 400 C 250 000 37C ASTM 37C Solvents Distillation 2 to 52 C 250 000 38C ASTM 38C Solvents Distillation 24 to 78 C 250 000 39C ASTM 39C Solvents Distillation 48 to 102 C 250 000 40C ASTM 40C Solvents Distillation W216 126 6 250 000 41C ASTM 41C Solvents Distillation 98 to 152 C 250 000 42C ASTM 42C Solvents Distillation 95 to 255 C 250 000 102C ASTM 102C Solvents Distillat
16. and fuel oils by extraction with toluene Sediment Extraction Apparatus e Conforms to ASTM D473 and related specifications A test portion of the sample is placed in a refractory thimble Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel The toluene washes out all of the crude oil or fuel oil leaving the insoluble residue only in the thimble The mass of the residue is calculated as a percentage and is referred to as the sediment by extraction Includes condenser thimble basket water cup and extraction thimble Ordering Information Specifications Conforms to the specifications of ASTM D473 IP 53 ISO 3735 DIN 51789 FIM 791 3002 NF M 07 010 SALTS IN CRUDE ANALYZER Catalog No Order Qty K48300 Sediment Extraction Apparatus 1 Accessories K42000 Powertrol Heater 115V 60Hz 1 K42090 Powertrol Heater 220 240V 50 60Hz K48400 Condenser K48500 Thimble Basket K48600 Water Cup K48700 Extraction Thimble Test Method Salt content is determined by measuring the conductivity of a solution of crude oil in a polar solvent when subjected to an alternating electrical current and is obtained by comparison of the resulting conductance to a calibration curve of known salt mixtures Electrometric Salt Determinator e Conforms to ASTM D3230 and IP 265 test specifications e GOST certified e Measures salt content conductance and temperature of crude oil Samples and pH measurements of aqueous sam
17. to 210 2 F 99 1 C Holds one 2 x15 51x381mm hydrometer jar top of jar extends 1 38mm above the top of the bath for easy viewing of the hydrometer Insulated double wall construction with stainless steel tank and shelf and finished steel exterior Has variable speed control for magnetic stirrer temperature control dial and on off switches for motor and power Specifications Temperature Range Ambient to 210 F 99 C Temperature Control Stability 2 F 1 C Bath Medium 2 gal 7 57L water Electrical Requirements 115V 60Hz Single Phase 4 3A 230V 50 60Hz Single Phase 2 2A Dimensions dia xh cm Bath Interior 6x16 15x42 Overall 9x22 23x56 Net Weight 20 Ibs 9 1kg Ordering Information Shipping Information shipping Weight 35 Ibs 15 9kg Dimensions 5 Cu ft Catalog No K26200 Constant Temperature Hydrometer Bath 115V 60Hz K26290 Constant Temperature Hydrometer Bath 230V 50 60Hz 00 COULOMETRIC KARL FISCHER TITRATOR Test Method Determines low concentrations of water in a wide range of liquid gas and powder samples Used for assessing water content in petroleum and petrochemical products including oils gasolines solvents and fluids as well as other products such as pharmaceuticals and cosmetics Coulometric Karl Fischer Titrator e ASTM D 1533 D4928 D6304 IP 386 IP 438 API MPMS Chap 10 9 BS 60814 ISO 10101 3 ISO 10337 ISO 12937 Simple operation Multi lang
18. 0Hz K90603 pH Conductivity Meter 115V 60Hz K90693 pH Conductivity Meter 230V 50Hz AUTOMATIC TITRATION Test Method For determination of Total Acid Number TAN Total Base Number TBN Mercaptan Sulfur and Karl Fischer Water Content of petroleum products lubricants and transformer insulating oils Titration is the fundamental chemical analysis procedure whereby the concentration of a chemical substance in solution is determined by reacting it with a measured amount of another chemical The Auto titrator performs this analysis using a motor driven dispenser stirred reaction vessel and electrodes which sense the completion of reaction by measuring the potential difference between two electrodes Automatic Titration increases accuracy repeatability and reproducibility as well as minimizing errors in calculation and documentation Automatic Titrator The Automatic Titrator is capable of performing a wide range of Titrations Acid base or aqueous titration Redox titration Complexometric titration or EDTA titration Blank titration silver Assay titrations Non aqueous titration Argentometric or Precipitation titration Voltametric KF Titration Back titration The Automatic Titrator is provided with two point auto calibration and Standardization zero offset The instrument is capable of displaying pH and mV of the sample with temperature compensation The Automatic Titrator can accept a variety of electrodes to cater to vario
19. 1 Bath Medium 400mL of heat transfer fluid 355 001 001 mineral oil is suitable for this application Electrical Requirements C 115V 60Hz Single Phase 6 5A 220 240V 50 60Hz Single Phase 13 4A Included Accessories Thermometer Ferrules 2 Clamps and Support Rod Dimensions xwxh in cm Shipping Information W 14x18x20 37x22x53 Shipping Weight 42 Ibs 19 1kg oN Net Weight 24 Ibs 10 9kg Dimensions 5 7 Cu ft K10190 Thin Film Aniline Point Apparatus Ordering Information Catalog No Order Qty U Tube Aniline Point Apparatus K10190 Thin Film Aniline Point Apparatus e Developed by Standard Inspection Laboratories 115V 60Hz 1 Similar to the Thin Film Aniline Point Apparatus but with U Tube K10191 Thin Film Aniline Point Apparatus aniline sample tube and stirrer as developed by Standard Inspection 220 240V 50 60Hz Laboratories Suitable for samples having 6 5 or lighter ASTM D1500 color As K10020 Powertrol Heater 115V 60Hz 1 illustrated in IP2 56 Method D Consists of U tube 400mL Borosilicate Glass K10029 Powertrol Heater 220 240V 50 60Hz beaker cover assembly with bath stirrer sample stirrer and cooling coil 6V EEEE lamp with line cord and drive motor Thermometer ferrules and mounting hardware are included Accessory Powertrol Heater provides variable stepless 250 000 33F ASTM 33F Thermometer control of heating rate and 6V tap for lamp Range 36 5 to 107 5 F 2 250 000 33C ASTM 33C Thermometer Ordering Inform
20. 12 30 5 13 33 7 3 1 4 K277C EXT18 18 45 7 Adjustable Level Sample Thief Takes samples at depths up to 12 30 5cm from bottom Similar to the standard 16 oz 473mL Sample Thief Bacon Bomb but with built in graduated extension rod adjustable between 0 12 30 5cm Plated brass construction Ordering Information Ordering Information Catalog No K27800 All Levels Sample Thief 66 Catalog No K27900 Adjustable Level Sample Thief SAMPLING OF PETROLEUM AND PETROLEUM PRODUCTS AND LPG Drum Thief Sampling Tube e Choice of plated brass or stainless steel construction For tube sampling from barrels and drums Takes bottom samples or all levels samples 40 Long x 1 dia 102x3 2cm Maximum sample capacity of 24 oz 710mL Shipping Weight 6 Ibs 2 7kg Ordering Information Catalog No K27400 Drum Thief plated brass K27401 Drum Thief stainless steel Weighted Beaker e Capacity 32 0z 946mL e Choice of or 1 19 or 38mm opening For beaker sampling from tank cars tank trucks shore tanks ship tanks and barge tanks Copper or stainless steel construction with weighted bottom Includes handle and chained cork Takes all level samples running samples and top upper middle lower and outlet samples Select 19mm opening for light crude oils light lubricating oils Kerosenes gasolines transparent gas oils diesel fuels and distillates or 1 88mm for heavy crude and fuel oils heavy lubri
21. 19 kg K33072 Programmable 28L 7 3 gal 120V 50 60Hz 22 9X13 19X14 7 5 in 12 13x10 38x8 in 50 Ibs K33073 240V 50 60Hz 55 6X93 9X9 aD CM 30 8x26 4x120 3 cm 23 kg 71 KOZNI INSTRUMENT COMPANY INC WATER IN PETROLEUM PRODUCTS amp BITUMINOUS MATERIALS BY DISTILLATION Test Method Determines the water content in petroleum products tars emulsified asphalts and other bituminous materials by the distillation method Distillation Apparatus e Conforms to ASTM D95 E123 D244 and related specifications Consists of still ring burner glassware and all mounting hardware Specifications Conforms to the specifications of ASTM D95 E123 D244 D370 AASHTO T55 T59 API MPMS Ch 10 5 IP 74 291 FIM 791 3001 ISO 3733 NF T 60 113 requires different glassware information is available upon request Shipping Information K31800 Shipping Weight 10 Ibs 4 5kg Dimensions 1 3 Cu ft K31810 K31820 Shipping Weight 18 Ibs 8 2kg Dimensions 2 8 Cu ft Ordering Information K31800 Metal Still Catalog No Order Qty Dean amp Stark Moisture Test Apparatus K31800 Metal Still 1 as Plated brass and copper with lid and e Conforms to ASTM D95 and related specifications clamp assembly gasket and O ring seal Consists of 400mm condenser 10mL receiver 1000mL flask and K31910 Ring Burner 5 12 7cm dia mounting equipment K31810 Glassware Set 1 Includes 400mL condenser 10mL and 25mL
22. 5V 60Hz K60095 FT Heated Oil Test Centrifuge 4 Place Finger Tube RA Ordering Information 990 240 50 60Hz Catalog No K60005 FT8 Heated Oil Test Centrifuge 8 Place Finger Tube RA 115V 60Hz ates A naa K60095 FT8 Heated Oil Test Centrifuge 8 Place Finger Tube RA marked in 200 parts every 4 parts above 20mL 220 240V 00 60Hz l l K61105 Centrifuge Tube Short 100mL 6 marked in mL K60006 Heated Oil Test Centrifuge 4 Place w Timer 115V 60Hz K61107 Centrifuge Tube Short 100mL 6 K60096 Heated Oil Test Centrifuge 4 Place w Timer 220 240V 50 60Hz marked in mL every 2mL above 10mL K60006 FT Heated Oil Test Centrifuge 4 Place Finger Tube w Timer K61108 Centrifuge Tube Short 100ml 6 marked in 200 parts 115V 60Hz K61141 Centrifuge Tube Finger Tube 12 5mL K60096 FT Heated Oil Test Centrifuge 4 Place Finger Tube w Timer K61111 Cork Stopper 220 240V 50 60Hz ASH FROM PETROLEUM PRODUCTS Test Method es Determines the amount of ash in distillate and residual fuels gas turbine Ri fuels crude oils lubricating oils waxes and other petroleum products Programmable Ashing Furnace e Six Complete Air Exchanges per Minute i e Incoming air preheated for enhanced temperature uniformity e Digital PID Temperature Control e Store up to 9 different programs e Integrated Timer e Maximum Temperature of 1100 C Specifications Conforms to the Specifications of ASTM D482 D874 D3174 D4422 D5184 E IP4 IP163 ISO 3987 I
23. 60 28L 7 3 gal 120V 50 60Hz 8 3A 15 19x21 65x10 13 in 11 63x19 56x7 94 in 33 Ibs K33061 240V 50 60Hz 4 15A 38 58x54 99x25 73 cm 29 54x49 68x20 17 14 97 kg 70 GENERAL PURPOSE BATHS K33064 Constant Temperature Circulating Bath Constant Temperature Circulating Baths e Above Ambient Temperature Control Programmable Model Constant temperature circulating bath provides precise temperature control stability of 0 01 C and features time temperature programming remote probe capability and a variable speed pressure suction duplex pump An RS232 interface and PC programming software are Standard while LabView drivers and Excel macros provide even greater programming and data logging conveinience A full graphic LCD display and multi language help menus simplify operation and set up Standard Model Economical constant temperature circulating bath model Microprocessor temperature control ranges from 5 C to 150 C with 0 05 C Stability This model features a bright set and read LED display with a readout accuracy of 0 5 C three user defined set point buttons and a 2 Speed pressure Simplex pump suitable for closed loop applications Specifications Temperature Range K33064 K33065 5 C to 200 C All Other Models 5 C to 150 C Temperature Stability Programmable Model 0 01 C standard Model 0 05 C Readout Accuracy Programmable Model 0 25 C standard Model 0 5 C Temperature Readout
24. 80 designation M 60 to 220 designation H 251 000 08H 8H 69 to 81 ASTM mam leet aa 79 to 91 Thermohydrometer API Gravity 91 000 10H 10 89 to 101 Catalog No No Range deg 251 000 51HH 51HH 1to11 Specific Gravity Hydrometers 251 000 51HL 51HL e Standard temperature 60 60 F subdivisions 0 0005 291 000 52HH 52HH 9 to 21 length 330mm 291 000 52HL 52HL 9 to 21 Ja 251 000 53HM 53HM 19 to 31 ASTM Nominal ir ne 251 000 53HL OSHL 19 to 31 atalog No 0 ange l SE UUU 251 000 82H 82H 0 650 to 0 700 rd cab eta ue Po 251 000 83H 83H 0 700 to 0 750 6 251 000 56HL S6HL 49 to 61 251 000 84H 84H 0 750 to 0 800 eB 251 000 57HL 9 HL 939 to 71 251 000 85H 85H 0 800 to 0 850 251 000 58HL O8HL 69 to 81 251 000 86H 86H 0 850 to 0 900 251 000 59HL O9HL 79 to 91 251 000 87H 87H 0 900 to 0 950 251 000 60HL 60HL 89 to 101 251 000 88H 88H 0 950 to 1 000 i 251 000 89H 89H 1 000 to 1 050 API Gravity Thermohydrometers 251 000 90H 90H 1 050 to 1 100 Thermometer in Stem standard temperature 60 F subdivisions 0 1 API Calibrated hydrometers and thermohydrometers are available length 380mm temperature scale F 30 220 from Koehler with an ISO IEC 17025 and ANSI NCSL Z 540 1 Report of Calibration ASTM Nominal o Thermohydrometer API Gravity When inquiring about calibrated hydrometers and thermohydrometers Catalog No No Range deg please refer to the catalog number for the corresponding hydrometer 251 000 71H 71H 4 to 11 thermohydrometer and replac
25. 85 D850 D1078 ISO 3405 DIN 51751 IP 128 56 57 Sulfur in Liquefied Petroleum Gases Oxy Hydrogen Burner ASTM D2384 D2747 D2784 D2785 80 GPA 2140 IP 243 ISO 4260 DIN EN41 58 Traces of Volatile Chlorides in Butane Butene Mixtures ASTM D2384 58 Trace Quantities of Total Sulfur Wickbold Apparatus ASTM D2785 58 Sulfur in Petroleum Products Wickbold Apparatus IP 243 58 Ramsbottom Carbon Residue of Petroleum Products ASTM D524 D6074 IP 14 ISO 4262 FIM 791 5002 oo cece 59 Lead in Gasoline by Volumetric Chromate Method ASTM D2547 IP 77 182 248 ISO 2088 ccssesssesssssessesssersessseneens 60 Acidity Inorganic of Petroleum Products by Color Indicator Titration Method P 182 oo cece cee eteteeeeeeeees 60 Test Methods Page Salt Content of Crude Petroleum and Products IP 77 0cce 60 Conradson Carbon Residue of Petroleum Products ASTM D189 D6074 ANS 2 11 25 IP13 ISO 6615 DIN 51551 FTM 791 5001 60 Sediment in Crude Oils and Fuel Oils by Extraction Method D473 IP 53 ISO 3735 DIN 51789 FIM 791 3002 oo eect cerns 61 Salts in Crude Oil Electrometric Method ASTM D3230 00 61 Water and Sediment in Crude Oils and Fuel Oils Centrifuge Method ASTM D91 D96 D893 D1796 D2273 D2709 D2711 D4007 IP 75 145 359 API 2542 2548 ISO 3734 DIN 51793 oo eceeseeeeteeeeeees 62 Water and Sediment in Crude Oils by Centrifuge
26. Built in Reverse Shipping Information shipping Weight 40 Ibs 18 1kg Dimensions 11 Cu ft Dimensions xwxh in cm Base Support Assembly 12x24x36 30 5x61x91 4 Ordering Information Catalog No K47100 Automated Flocculation Titrimeter 115V 60Hz K47190 Automated Flocculation Titrimeter 230V 50 60Hz In collaboration with Western Research Institute DISTILLATION OF PETROLEUM PRODUCTS AT REDUCED PRESSURE Test Method Determines the range of boiling points for petroleum products that can be partially or completely vaporized at a maximum liquid temperature of 400 C at reduced pressures The sample is distilled at a controlled reduced pressure under conditions that are designed to provide approximately one theoretical plate fractionation Initial and final boiling point is measured and a distillation curve relating volume percent distilled and the atmospheric equivalent boiling point temperature can be prepared VDS3000 Manual Vacuum Distillation System e Conforms to ASTM D1160 and related specifications e Comes standard with glassware set and accessories kit for Turn Key set up and operation e Sturdy cabinet composed of aluminum frame and cold rolled Steel walls e Control Unit can easily attach and detach from the main unit offering versatility for laboratory workspace e Clear protective door provides added safety while allowing the operator full view of the system during testing e Equipped with digital temperature an
27. C Fully automatic function minimizes the amount of operator time needed for the test The latest Windows operating system is included along with a state of the art PC The Windows based software is intuitive and guides you through the distillation step by step All data is saved to the hard drive in standard format that can be easily opened by spread sheets or exported to LIMS Files can be accessed through portable USB drives Ethernet connection or written to a CD DVD A color printer is provided to print hard copies of the reports Process diagrams clearly show the current equipment status Results can be viewed as the distillation proceeds in both tables and graphs Distillation parameters can be modified at any time during the distillation Semi Automatic Vacuum Distillation System e Automatic Vacuum Control e Automatic Heat Control e Vapor Temperature Display e Pot Temperature Display e Automatic shutdown for high pot or vapor temperature The Semi Automatic Vacuum Distillation System features standard ASTM D1160 glassware enhanced with microprocessor control The vacuum level bath temperature and heating rates are programmable with up to 50 stored programs Vapor temperature distilling flask temperature and vacuum level are digitally displayed Optional PC interface allows the distillation to be controlled from a PC and for data to be stored on the PC Specifications Conforms to the Specifications of ASTM D1160 ISO 6616 Di
28. Combustion Apparatus e Conforms to ASTM D2384 D2784 and related specifications Burns samples in a stainless steel oxy hydrogen burner to determine total Sulfur in petroleum products in the 0 1 to 300ppm range Tests samples which are viscous highly aromatic or of high sulfur content with the use of appropriate solvents Combustion chamber and stainless steel burner are housed in an insulated chamber with hinged heat resistant and glare proof shield for viewing burner flame To ignite flame depress electronic spark ignitor handle at side of unit Ignitor shuts off when handle is released Built in pressure regulators with gauges allow for accurate adjustment and monitoring of hydrogen oxygen and nitrogen pressure Burner is easily disassembled for cleaning Supplied with a complete set of Borosilicate Glass and quartz glassware including 200mL sample reservoir sample capillary combustion chamber absorber spray trap and cooling bulb and compression type gas connection fittings for 6mm O D tubing Housed in a finished aluminum cabinet For LPG natural gas and refinery gas samples order accessory sample adapter Ordering Information 08 Catalog No Order Qty K47500 Wickbold Apparatus 115V 60Hz 1 K47590 Wickbold Apparatus 220 240V 50 60Hz Accessories K47580 Gas Sample Adapter 1 For burning liquefied petroleum natural and refinery gases in the Wickbold Apparatus Constructed entirely of stainless steel with 150mL sa
29. For sub ambient temperatures refrigerated recirculating coolant is required from an external source Temperature Uniformity 0 02 C Temperature Limit Control 16 7 C 30 F above setpoint and 204 C 400 F maximum Heater Range 0 750W Circulator hp impeller Working Depth Oil Bath 12 30 5cm Ice Bath 10 26 7cm Electrical Requirements C 115V 60Hz 220 240V 50 60Hz Catalog No Order Qty K26500 Thermometer Calibration Bath 115V 60Hz 1 K26590 Thermometer Calibration Bath 220 240V 50 60Hz Accessories K26501 Standard Thermometer certified traceable to NIST Standards 1 at 0 20 37 56 80 100 121 140 160 180 and 200 C K26503 Thermometer Magnifier 10X 1 K26502 Thermometer Carrying Case 1 holds K26501 Standard Thermometer PH CONDUCTIVITY METERS pH Meter This bench top pH meter is an ideal help in every laboratory for routine or R amp D level measurement This instrument measures pH mV and has 40 point data memory storage Instrument has two operating modes 1 Standard mode 2 GLP mode 40 data readings can be stored printed and scanned on display For GLP mode additional entries of sample name and ID number can be stored The optional Data logging function enables the user to store 24 data points consisting of pH temperature and time readings For example as required in kinetic study or in any chemical reaction Time intervals from 1min to 1Hr in steps of 1min are available User e
30. GENERAL TEST EQUIPMENT Test Methods Page Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents ASTM D611 IP 2 ISO 2977 DIN 51775 PIM OU Ye etnar n 42 43 Saybolt Color of Petroleum Products ASTM D156 DIN 51411 FIM 791 10 44 46 47 ASTM Color of Petroleum Products ASTM D1500 D6074 IP 196 ISO 2049 FTM 791 102 nee 45 46 Visual Examination of Used Electrical Insulating Oils of Petroleum Origin in the Field ASTM D1524 oo eseesesseeseessen 45 Automated Colorimeter ASTM D156 D1209 D1544 D1925 D6166 ISO 2049 4630 6271 DIN 5033 6162 6174 AOCS CC 13E USP CH 631 1061 PH EUR NF M 07 003 NF T 60 104 ccce 47 Density Relative Density Specific Gravity or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method ASTM D287 D1298 D6074 D6159 E100 API MPMS Chapters 9 1 IP 60 190 367 95 DIN S17 57 vccincierrsrratveecesevsdvcreamtantaameniemncnstanenatets 48 50 Water in Oils Gas Powders by Coulometric Karl Fischer Titration ASTM D1533 D4928 D6304 IP 386 API Chapter 10 9 ocne 51 Automatic Flocculation Titrimeter 00 0 52 Distillation of Petroleum Products at Reduced Pressures ASTM D1160 SO GOA Gv is ccvesccrncsvicasavieavienrsrviandeanesexvuiuldstnscmannennd 53 54 Distillation of Petroleum Products ASTM D86 D216 D233 D447 D850 D1078 E133 IP 123 195 ISO 3405 DIN 51751 FIM 791 1001 791 1015 55 Automatic Distillation System ASTM D86 D2
31. SO 6245 NF M 07 045 DIN 51352 DIN 51575 E e i Temperature Range Ambient 1100 C Temperature Accuracy 3 C E Oven Volume Power 0 07 cu ft model 3 L 0 07 cu ft model 1 2 kW 0 16 cu ft model 5 L 0 16 cu ft model 2 4 kW 0 33 cu ft model 9 L 0 33 cu ft model 3 0 kW al i l 0 47 cu ft model 15 L 0 47 cu ft model 3 6 kW K24308 Programmable Ashing Furnace Ordering Information Electrical Requirements C 208V 50 60Hz Single Phase 240V 50 60Hz Single Phase Catalog No K24305 Programmable Ashing Furnace 0 07 cu ft 208V 50 60Hz Dimensions wxdxh in cm Net Weight Ibs kg K24306 Programmable Ashing Furnace 0 16 cu ft 208V 50 60Hz 0 07 cu ft model 14 96x14 57x29 53 38x37x75 Net Weight 44 1 20 K24307 Programmable Ashing Furnace 0 33 cu ft 208V 50 60Hz 0 16 cu ft model 17 33x18 50x33 46 44x47x85 Net Weight 77 2 35 K24308 Programmable Ashing Furnace 0 47 cu ft 208V 90 60Hz 0 33 cu ft model 18 90x21 66x35 44 48x55x90 Net Weight 99 3 45 ee PUOC Dn oie a AUE WANG Buu eee Sool 0 47 cu ft model 18 90x25 59x35 44 48x65x90 Net Weight 121 3 55 K24396 Programmable Ashing Furnace 0 16 cu ft 240V 50 60Hz K24397 Programmable Ashing Furnace 0 33 cu ft 240V 50 60Hz K24398 Programmable Ashing Furnace 0 47 cu ft 240V 50 60Hz KOL CANA INSTRUMENT COMPANY INC 63 AUTOMATIC DENSITY METER Test Method Density is a fundamental physical property that can be us
32. TM color standards in an oil comparator Oil Comparator e Conforms to ASTM D1524 specifications e Yields results equivalent to ASTM D1500 Complete ASTM oil color test outfit for comparison of oils against ASTM color Standards Includes two color discs ranging from 0 5 to 5 0 in 10 steps and 5 0 to 8 0 in 7 steps Magnifying prism brings the sample and standard color fields together for side by side comparison Portable unit is suitable for laboratory or field use Supplied with two precision 33mm rectangular glass cells carrying case and instructions Shipping Information shipping Weight 10 Ibs 4 5kg Dimensions 1 Cu ft Ordering Information Catalog No Order Qty K13203 Oil Comparator 1 Accessories K13204 Daylight Illuminator 115V Provides uniform lighting for Oil Comparator 1 K13294 Daylight Illuminator 220 240V K13205 Rectangular Glass Cell Keale INSTRUMENT COMPANY INC 45 PORTABLE AUTOMATED COLORIMETER K13260 Portable Automatic Colorimeter with K13351 Cylindrical Cuvette and K13353 Rectangular Cuvettes Both Sold Separately Specifications Conforms to the specifications of ASTM D156 D1209 D1544 D6045 ISO 4630 6271 DIN 6162 NF M 07 003 NF T 60 104 JIS K2580 Reproducibility 0 2 T referenced to distilled water Reference Standard distilled water Data Output RS232 printer Light Source krypton lamp 7 9x10x3 5 20x26x90 Net Weight 2 9 Ibs 1 3kg Shipping Information Electric
33. Vacuum Pump with Kit 1 Consists of Vacuum Pump Hose Nozzle Centering O Ring Hinged Clamp Outlet Filter Filter O Ring Filter Clamp 1 Liter Vacuum Oil Connection Tubing Hose Clamp 2 Standard Constant Temperature Circulation Bath 115V 60Hz Standard Constant Temperature Circulation Bath 220 240V 50 60Hz K33062 K33063 KL INSTRUMENT Ner INC 93 AUTOMATIC AND SEMI AUTOMATIC VACUUM DISTILLATION OF PETROLEUM PRODUCTS Test Method Determines the range of boiling points for petroleum products that can be partially or completely vaporized at a maximum liquid temperature of 400 C at reduced pressures The sample is distilled at a controlled reduced pressure under conditions that are designed to provide approximately one theoretical plate fractionation Initial and final boiling point is measured and a distillation curve relating volume percent distilled and the atmospheric equivalent boiling point temperature can be prepared Automatic Vacuum Distillation System e Fully Automatic Operation e Simple to Operate and Maintain e Vacuum Step Down Inhibits Foaming e Easy Access to all Components e Safety Shields amp Doors Protect Operator e Turn Key System e High Precision and Accuracy e Automatic Cleaning Cycle e Receiver is Easy to Remove e PC Control The Automatic Vacuum Distillation System is designed to make vacuum distillation easy safe and affordable The self contained unit is controlled by a Standard P
34. al Requirements 115 240V 50 60Hz C Dimensions xwxh in cm shipping Weight 10 Ibs 4 5kg Portable Automated Colorimeter e Conforms to ASTM D156 D1544 D1209 DIN 6162 and related international test specifications e Measures the 4 most important color scales used for liquid chemicals resins oils fuels and fats for liquid color measurement e Portable design for remote applications Single beam filter colorimeter system utilizes reference beam path technology to measure samples over eight spectral wavelengths ranged between 400 and 700nm in comparison to 4 standard color scales Provides photometric high precision color measurements that are objective accurate and consistent over a wide variety of samples required for quality control programs Measurements are initiated by just a single key press and require less than one minute to complete The test results can be either displayed on the LCD screen or sent to an external printer Please contact Koehler Customer Support for assistance on additional accessories required for your application Color Ranges e Saybolt Color ASTM D156 NF M 07 003 e Iodine Color DIN 6162 e Hazen Color APHA Color Pt Co Color ASTM D1209 ISO 6271 e Gardner Color ASTM D1544 ISO 4630 Ordering Information Catalog No K13260 Portable Automatic Colorimeter Accessories K13551 Starter Kit Consists of Addista Color Standards 50 x 10 Rectangular Cuvettes Pk 10 Cuvette Set 10 x 11m
35. ale INSTRUMENT COMPANY INC LEAD IN GASOLINE ACIDITY SALT CONTENT Lead in Gasoline by Volumetric Chromate Method Acidity Inorganic of Petroleum Products by Color Indicator Titration Method Salt Content of Crude Petroleum and Products Test Method Determines lead acid or salt content of crude petroleum and products by extraction Dual Extraction Apparatus e Conforms to ASTM D2547 IP 77 182 248 and ISO 2083 specifications Consists of two sets of glassware mounted on a sturdy base upright assembly with separate line switches rheostats and condenser water control valves for each Each glassware set includes 500mL boiling flask with heating tube Hopkins reflux condenser with aspirator thistle tube 250W heating coil and 400mL Borosilicate Glass beaker Specifications Dimensions xwxh in cm Conforms to the specifications of 17x11x36 43x28x93 ASTM D2547 Withdrawn 1989 Net Weight 46 Ibs 21kg IP 77 182 248 ISO 2083 AO NF M 07 014 07 023 Shipping Information Electrical Requirements C Shipping Weight 66 Ibs 30kg 115V 60Hz DONET 220 240V 50 60Hz Ordering Information K46600 a C i atalog No Order Qty Dual Extraction K46600 Dual Extraction Apparatus 115V 60Hz 1 Apparatus i w K46690 Dual Extraction Apparatus 220 240V 50 60Hz Test Method Provides an indication of relative coke forming properties of petroleum oils The residue remaining after a specified period of evaporation and pyrolys
36. and the special configuration for data exchange can be implemented at any time with LIMS In combination with special halogen resistant decomposition vessels quantitative decompositions can be performed to determine halogen and Sulfur content Dimensions xwxh in cm 174x17x19 440x450x500 Net Weight 66 Ibs 30 kg Specifications Conforms to the specifications of ASTM D240 D4809 D5865 D1989 D5468 E711 ISO 1928 DIN 51900 BS1016 Measurement range 40 000 J Measuring mode Isoperibolic 25 C Isoperibolic 30 C Dynamic 25 C Dynamic 30 C lsoperibolic Measuring Time Approximately 22 min Dynamic Measuring Time Approximately 7 min Oxygen Operating Pressure 30 bar Cooling Medium Water via line flow through quantity 60 10 liters hour Water Operating Pressure 1 1 5 bar max Water Test Pressure 10 bar Interfaces Serial RS232 Parallel Keyboard Sample rack External monitor Ordering Information Catalog No K88800 Automatic Calorimeter 115V 60Hz K88890 Automatic Calorimeter 220V 50Hz Accessories K88800 1 Cooling water supply unit 115V 60Hz K88890 1 Cooling water supply unit 220V 50Hz K88800 2 Pressure Gauge Oxygen To reduce the pressure of the oxygen cylinder to 30 bar K88800 3 Standard Decomposition Vessel K88800 4 Decomposition Vessel Halogen Resistant For quantitative decomposition determine halogen and Sulfur content K88800 5 Connection valve Required for permanently installed water connection
37. ardner Color saybolt Klett color Hess lves ADMI Yellowness index AOCS Red Yellow Chlorophyll A CIE Lab Hunter Lab XYZ European and US Pharmacopoeia Photometer methods e Wavelength Scan 320 1100nm incl Difference Mode e Time Course Mode e Single and Multi Wavelength Mode Ordering Information Catalog No K13550 Automatic Colorimeter 115 240V 50 60 Hz Accessories K13551 Starter Kit Consists of Addista Color Standards 50 x 10 Rectangular Cuvettes Pk 10 Cuvette Set 10 x 11mm round glass cuvettes K13552 USB Barcode Scanner hand held scanner K13553 Test filter set for stray light absorbance and wavelength check K13554 USB Keyboard keyboard layout US K13253 Certified Testing solution set Addista Color K13351 Round cuvettes 11mm glass disposable pk 500 K13353 Rectangular cuvette 50 x 10mm plastic disposable pk 50 K13349 Rectangular cuvette 50 x 10mm with caps plastic disposable pk 10 K13250 1 Rectangular cuvette 50 x 10 glass pk 1 K13500 3 Rectangular cuvette 10 x 10 glass pk 3 K13550 1 Printer for K13550 K13356 Rack for 7 50x10 cuvettes Please use the K18250 1 Rectangular cuvette 50 x 10 glass pk 1 or K13500 3 Rectangular cuvette 10 x 10 glass pk 3 when testing hydrocarbons for color measurements The disposable polycarbonate cuvettes are made for aqueous samples Please ask you Koehler Sales Representative for details 47 K13550 Automatic Colorimeter with K13351 Cylindrical Cuvettes an
38. ation Range 38 to 42 C Catalo g No Order Qty 250 000 34F ASTM 34F Thermometer K10090 U Tube Aniline Point Apparatus Range 77 to 221 F 2 115V 60Hz 250 000 320 ool es a K10091 U Tube Aniline Point Apparatus 1 ange 25 to 105 220 240V 50 60Hz 250 000 35F ASTM 35F Thermometer K10020 Powertrol Heater Range 194 to 338 F 2 115V 60Hz l Range 90 to 170 C 220 240V 50 60Hz For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 Keale INSTRUMENT COMPANY INC 43 SAYBOLT COLOR OF PETROLEUM PRODUCTS Specifications Conforms to the specifications of ASTM D156 DIN 51411 FTM 791 101 NF M 07 003 Electrical Requirements C 115V 60Hz 220 240V 50 60Hz Included Accessories Whole Color Standards 3 Half Color Standard 1 Engraved Conversion Chart Dimensions Ixwxh in cm 5x5 4x26 14x14x67 Net Weight 15 Ibs 7kg Shipping Information shipping Weight 31 Ibs 14 1kg Dimensions 4 0 Cu ft Includes accessory lamp 44 Test Method The Saybolt Color test is used for quality control and product identification purposes on refined products having an ASTM Color of 0 5 or less Products in this range include undyed motor and aviation gasolines jet propulsion fuels naphthas kerosene and petroleum waxes Color is an important quality characteristic for many products and can also be used to detect product contamination The Saybolt Chromometer measures c
39. cating oils and nontransparent gas oils Shipping weight 6 lbs 2 7kg Ordering Information Catalog No K27600 Weighted Copper Beaker with opening K27610 Weighted Copper Beaker with 1 opening 5 K27601 Weighted Stainless Steel Beaker K27400 K27600 with opening Drum Thiet Weighted Beaker LPG Sample Containers e Two valve type with 20 outage tube e Built in pressure relief valve e Conforming to ASTM D1265 and GPA 2140 specifications Welded stainless steel cylinders for obtaining representative samples of liquefied petroleum LP gases Two valve type IPS with 20 outage tube and built in pressure relief valve factory preset between 540 to 600psi 38 42 kg cm Ordering Information Catalog No K27851 LPG Sample Cylinder 150mL K27852 LPG Sample Cylinder 300mL K27853 LPG Sample Cylinder 500mL K27854 LPG Sample Cylinder 1000mL K27856 LPG Sample Cylinder 3000mL K27851 Series LPG Sample Cylinder Core Type Sampling Thief Tulsa Oil Thief Specifications e Obtains bottom samples or samples from any level Conforms to the specifications of ASTM D4057 Capacity 330z Empty Weight 6 187 Ibs sample Container Material Polycarbonate e Butterfly valve on bottom for easy sampling e Stainless steel and brass construction e Three Petcocks for draining at different levels ae i oe Markings E hf to 14 The K28100 Core Type Sampling Thief is used to manually obtain samples of a Sie van Calc hata
40. ces to a 10 20 micro inch finish 2x4x 51X102x3 2mm 380 240 002 Aluminum Oxide Cloth 240 grit 1 For test panel preparation Pack of 50 250 000 09F ASTM 9F Thermometer Range 20 to 230 F 1 250 000 09C ASTM 9C Thermometer Range 5 to 110 C For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 Digital Flowmeter option is available for this unit 65 Specifications Conforms to the specifications of ASTM D1748 FIM 791 5310 Capacity 33 rust test specimens Water Level Control 8 in 203mm Temperature Control Stability 2 F 1 1 C air temperature Heater Range 0 1500W Air Metering 0 878 0 02832m h at standard temperature and pressure 31 1 ft h Air Distribution 20 diffuser manifold Rotating Stage 4rpm Electrical Requirements 115V 60Hz Single Phase 13 0A 220 240V 50Hz or 60Hz Single Phase 6 8A Included Accessories Monel Test Specimen Hooks 33 sets Dimensions Ixwxh in cm 32x28x41 81x71x105 Net Weight 206 Ibs 93 4kg Shipping Information Shipping Weight 279 Ibs 126 6kg Dimensions 41 Cu ft KOSMET INSTRUMENT COMPANY INC SAMPLING OF PETROLEUM AND PETROLEUM PRODUCTS AND LP GASES K27790 K27760 Specifications and Ordering Information Sampling of Petroleum and Petroleum Products Sampling Liquefied Petroleum LP Gases Test Method Standards All samplers conform to ASTM D4057 fo
41. cts at Reduced Pressures Pages 53 54 ASTM D1160 Toluene Nitrogen Cyclohexane Balance n Tetradecane n Hexadecane 1L Beaker Calcium Chloride Boiling Chips silicone Fluids Sulfur in Liquefied Petroleum Gases OXy Hydrogen Burner occ cece eeescecseecseeeeeeeeees Page 58 ASTM D2784 Oxygen Hydrogen Nitrogen sulfuric Acid Acetone lsopropanol Hydrogen Peroxide Glycerin Methylene Blue Vacuum Source Alcohol Distilled Water Thorin Carbon Dioxide Perchloric Acid Barium Chloride Dihydrate Spectrophotometer Denatured Ethyl Alcohol sodium Hydroxide Hydrochloric Acid Low Sulfur Acetone Barium Perchlorate Safety Shield Fleisher s Methyl Purple Indicator 78 Traces of Volatile Chlorides in Butane Butene Mixtures eee Page 58 ASTM D2384 Mercuric Thiocyanate Nitrogen Potassium Nitrate Nitric Acid saturated Calomel Electrolyte lron Wire Mercury Calomel Mixture Hydrogen Silver Nitrate Hydrogen Peroxide Gelatin Bromthymol Blue Indicator Acetone sodium Carbonate Hydrochloric Acid Titration Equipment Perchloric Acid Oxygen Agar Powder Vacuum Source Ramsbottom Carbon Residue Of Petroleum Products 0 cesses seers Page 59 ASTM D524 IP 14 ISO 4262 FTM 791 5002 Desiccator otrainer 100 mesh Analytical Balance Calcium Chloride syringe Sediment in Crude Oils and Fuel Oils by the Extraction Method Page 61 ASTM D473 IP 53 ISO 3735 DIN 51789 FTM 791 3002 Desiccator Toluene Analytical Ba
42. d K13353 Rectangular Cuvette Both Sold Separately Included Accessories e Universal power supply 100 240V 50 60 Hz with exchangeable plug adapters for EU GB US China e Dust Cover e User Manual Specifications Conforms to the specifications of ASTM D156 D1209 D1544 D1925 D5386 D6045 D6166 ISO 4630 6271 DIN 5033 6162 6174 AOCS Cc 13e USP Ch 631 1061 Ph EUR NF M 07 003 NF T 60 104 spectral Bandwidth 5 nm Wavelength Reproducibility 0 1nm Wavelength Resolution tnm scanning Speed 12 nm s in steps of 1 nm Stray Light lt 0 1 T at 340 nm with NaNO2 Color Measurement 380 720nm in steps of 10nm Wavelength Range 320 1100nm in steps of 1nm Wavelength Accuracy 1 5 nm wavelength range 340 900 nm Photometric Measuring Range 3 5 Abs wavelength range 340 900 nm Photometric Accuracy 5 m Abs at 0 0 to 0 5 Abs 1 at 0 50 to 2 0 Abs Photometric linearity lt 0 5 to 2 Abs 1 at gt 2 Abs with neutral glass at 546 nm Light Source Gas filled Tungsten visible Dimensions xwxh in cm 14 5 x 14 1 x 5 7 36 8 x 35 9 x 14 4 Net Weight 14 11 Ibs 6 4 kg Shipping Information shipping Weight 18 Ibs 8 2 kg Dimensions 20x16x16in Electrical Requirements 115 240V 50 60 Hz C GEE INSTRUMENT niet INC DENSITY RELATIVE DENSITY SPECIFIC GRAVITY OR API GRAVITY Density Relative Density API Gravity Hydrometers Specific Gravity f Standard temperature 60 F subdivisions 0 1 API o
43. d rate After the two phases become miscible the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample Automatic Aniline Point Apparatus e Conforms to ASTM D611 and related specifications e For samples ranging from clear to very dark e Temperature range 0 C to 150 C 32 F to 302 F e Digital temperature display Performs aniline point and mixed aniline point determinations automatically by means of a modified thin film technique ASTM D611 Method E The Sample aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically Temperature is displayed on a large LED indicator Built in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures Aniline points as low as 0 C 32 F can be determined with the use of refrigerated cooling air Equipped with variable controls for heater light source and stirrer speed Cabinet exterior Surfaces have a chemical resistant polyurethane enamel finish Specifications Conforms to the specifications of ASTM D611 IP 2 ISO 2977 DIN 51775 FTM 791 3601 NF M 07 021 Testing Range 0 to 150 C 32 to 302 F Temperature Display 0 999 9 C Electrical Requirements C 115V 60Hz Single Phase 0 4A 220 240V 50 60Hz Single Phase 0 2A Included Accessories Stan
44. d vacuum displays for improved measurement reading and accuracy e Upgrade to glassware set composed entirely of quartz available upon request The Koehler VDS3000 Manual Vacuum Distillation System is the latest design for determining at reduced pressures the range of boiling points for petroleum products according to ASTM D1160 and related Specifications The main body of the system or cabinet is composed of an aluminum frame and cold rolled steel walls The base of the cabinet houses a 5 Liter Stainless Steel Surge Tank to reduce pressure fluctuations during testing The control unit of the system features a versatile compact modern design Dual temperature displays independently show both the overhead and flask temperature of the system Built in cooling fan rapidly cools the distilling flask allowing the user to handle glassware and shorten turnaround time in between test runs Equipped with complete glassware set and accessories kit for Turn Key installation and operation of the Vacuum Distillation System The Standard Glassware Set consists of 500mL quartz distilling flask with thermowell vacuum jacketed distilling column and condenser assembly water jacketed receiving cylinder 90 elbow adapter tube Dewar Type Cold Trap with 10mL graduated receiver and stopcock drain PT100 probe adapter PT100 vapor temperature probe and PT100 flask temperature probe The system also includes an adjustable scissor jack heating mantle retainin
45. dard Borosilicate Glass Test Cell with drain Dimensions xwxh in cm 14 x8 x20 37x22x53 Net Weight 32 Ibs 14 7kg Shipping Information shipping Weight 46 Ibs 21kg Dimensions 8 2 Cu ft ANILINE POINT AND MIXED ANILINE POINT OF PETROLEUM PRODUCTS Thin Film Aniline Point Apparatus e Conforms to ASTM D611 and related specifications For aniline point and mixed aniline point determinations according to Method B Stirs aniline sample mixture in a borosilicate glass thin film tube suspended in a heating bath Thin film of mixture flows over a light well illuminated by a variable 6V lamp Adjust heating rate per specifications using accessory Powertrol Heater When lamp filament brightens inside well allow mixture to cool until the two phases separate as indicated by obscuring of the lamp filament Consists of thin film tube 400mL Borosilicate Glass beaker cover assembly with bath stirrer sample pump rotor and cooling coil 6V lamp with line cord and drive motor Positive drive pulley system rotates sample and bath stirrers Accessory Powertrol Heater has variable stepless control and a reference dial for repeatable control of heating rate Porcelain refractory top plate shields 1000W heater and has a positioning well for the Borosilicate Glass bath Low voltage receptacle in heater housing accepts line cord of 6V lamp Specifications Conforms to the specifications of ASTM D611 IP 2 ISO 2977 DIN 51775 FTM 791 3601 NF M 07 02
46. dation Test Reactor is a complete solution controlled entirely by the Windows based oxidation software capable of providing high added value information concerning fat oxidation processes in foods oils fats and biodiesel fuels The Oxidation Test Reactor works directly on the whole sample without the need for preliminary fat separation and is suitable for the determination of the quality and the state of preservation of the sample An extremely simple and intuitive instrument equipped with two separate titanium chambers in order to analyze the same sample in duplicate or different samples at the same time under the same conditions The stability of the sample is determined by accelerating the oxidation process using high temperatures from Ambient to 110 C and a pre determined oxygen pressure Oxygen is consumed during fat oxidation and it is this decrease in oxygen pressure that enables us to obtain useful information concerning the sample The intuitive software controls the entire process in a user friendly way and the operator can record data in a database compare tests export the data to an Excel file filter and order the data quickly and easily FATS AND BIODIESEL FUELS K83100 Oxidation Test Reactor Specifications Based on the Specifications of ASTM D942 IP 142 Temperature Range Ambient to 110 C Number of Oxidation Chambers 2 Chamber Capacity 100mL Pressure Range 0 8 bar Interface USB Overpressure Sa
47. e PT100 Thermometer with Cable and Plug Special Graduated Receiver Cylinder with base Special Graduated Receiver Cylinder without base Condenser Tube Cleaning Assembly Dropping Plate Flask 200mL with Silicon Plug Silicone Plug Automatic Dry Point Detection Kit for D850 and D1078 Keale INSTRUMENT COMPANY INC SULFUR TRACE SULFUR VOLATILE CHLORIDES K47590 Wickbold Combustion Apparatus Specifications Conforms to the specifications of ASTM D2384 D2747 Withdrawn 1985 D2784 D2785 Withdrawn 1987 GPA 2140 IP 243 ISO 4260 DIN EN 41 NF T 60 142 Electrical Requirements 115V 60Hz 220 240V 50 60Hz Included Accessories Complete Glassware Set Sample Capillary Sample Reservoir Combustion Chamber Absorber Spray Trap Cooling Bulb Stainless Steel Burner Dimensions Ixwxh in cm Cabinet only 15x13x18 38x33x47 Net Weight 40 Ibs 18 1kg Shipping Information Shipping Weight 62 Ibs 28 1kg Dimensions 11 9 Cu ft Sulfur in Liquefied Petroleum Gases Oxy Hydrogen Burner Traces of Volatile Chlorides in Butane Butene Mixtures Trace Quantities of Total Sulfur Wickbold Apparatus Sulfur in Petroleum Products Wickbold Apparatus Test Method Determines total sulfur in liquefied petroleum LP gases and in liquid petroleum products by the Wickbold oxy hydrogen burner method Also Suitable for burning butane butene mixtures to determine trace amounts of volatile chlorides Wickbold
48. e the middle three zeros in the catalog number with 004 Example 251 000 01H API Gravity Hydrometer would 251 000 72H 72H 9 to 21 be 251 004 01H Certified API Gravity Hydrometer 251 000 73H 73H 19 to 31 251 000 74H 74H 29 to 41 48 DENSITY RELATIVE DENSITY SPECIFIC GRAVITY OR API GRAVITY Specific Gravity Hydrometers Standard temperature 60 60 F subdivisions 0 001 length 260mm Hydrometer Cylinders e Wide base for maximum stability e Convenient pour out lip ASTM Nominal l Hydrometer Specific Gravity e Choice of glass or metal construction Catalog No No Range 251 000 102H 102H 0 650 to 0 700 251 000 103H 103H 0 700 to 0 750 251 000 104H 104H 0 750 to 0 800 251 000 105H 105H 0 800 to 0 850 251 000 106H 106H 0 850 to 0 900 251 000 107H 107H 0 900 to 0 950 251 000 108H 108H 0 950 to 1 000 251 000 125H 125H 1 000 to 1 050 251 000 126H 126H 1 050 to 1 100 251 000 127H 127H 1 100 to 1 150 251 000 128H 128H 1 150 to 1 200 251 000 129H 129H 1 200 to 1 250 251 000 130H 130H 1 250 to 1 300 251 000 131H 131H 1 300 to 1 350 251 000 132H 132H 1 350 to 1 400 251 000 133H 133H 1 400 to 1 450 251 000 134H 134H 1 450 to 1 500 251 000 135H 135H 1 500 to 1 550 251 000 136H 136H 1 550 to 1 600 251 000 137H 137H 1 600 to 1 650 251 000 138H 138H 1 650 to 1 700 251 000 139H 139H 1 700 to 1 750 251 000 140H 140H 1 750 to 1 800 251 000 141H 141H 1 800 to 1 850 K26300 Brass Hydrometer Cylinder Ordering Information ASTM Metric Thermohyd
49. ed in conjunction with other properties to characterize the quality of crude oils light and heavy fractions of petroleum and petroleum products The test method covers the determination of the density or relative density of crude oils petroleum distillates and viscous oils that can be handled in a normal fashion as liquids at test temperatures between 15 and 35 C Specifications Conforms to the specifications of ASTM D1250 D4052 D5002 D5931 DIN 51757 Measurement Ranges Density 0 to 3 g cm3 Temperature 0 C to 90 C Pressure 0 to 10 bars Measurement Modes Continuous Single Multiple Accuracy K86200 Density 0 00005 g cm3 Temperature 0 03 C K86201 Density 0 0001 g cm3 Temperature 0 05 C Repeatability K86200 Density 0 00001 g cm3 Temperature 0 01 C K86201 Density 0 00005 g cm3 Temperature 0 02 C Density 0 00001 g cm3 Temperature 0 01 C Minimum Sample Volume 1 ml approximately Wetted Materials Borosilicate glass Teflon PTFE ECTFE Display 10 4 inch diagonal 800 600 pixels color Flat Panel Monitor with Resistant Touch Screen Interface 200 bit brightness gasketted for Spill protection Communication Interface K86200 Touch Screen User Interface 3 USB Ports 2 RS232 Ports Ethernet Port for Network Connection Keyboard Bar Code Scanner Mouse Network Capabilities K86201 Touch Screen User Interface 3 USB Ports 1 Cat 5 Port 2 RS232 Ports Keyboard Bar Code Scanner Mouse N
50. ermine the point of flocculation asphaltene precipitation and calculate the Heithaus compatibility parameters These results are intended primarily as a laboratory diagnostic tool for estimating the colloidal stability or compatibility of asphalt asphalt cross blends aged asphalt pyrolyzed asphalt crudes and heavy oil residuum The stability values will allow the refiner to increase yields by allowing longer retention time in process The compatibility values will allow blending of crudes so as to prevent asphaltene formation during blending and storage Both of these parameters are of utmost importance when we consider the price of crude in today s market Automated Flocculation Titrimeter e Complete instrument and data acquisition system e Rapid accurate and highly reproducible e Determines blending insolubility and solubility numbers e Generates the data to calculate the WRI Coking Index patent pending to predict the proximity to coke formation during heavy oil distillation and improve distillate yield The Automated Flocculation Titrimeter AFT is a highly automated computerized instrument that acquires oil stability and compatibility parameters directly The AFT can be used to perform ASTM D6703 test method for Automated Heithaus Titrimetry The instrument operates as a closed system with accurately controlled temperatures between 20 100 C important for properly determining Heithaus compatibility parameters The flocculation
51. etwork Capabilities Video and Magnification Video assisted view of cell capable of approximately 10X magnification Internal Memory 2 GB Non removable Compact Flash Electrical Requirements 85 to 260 VAC 48 to 62 Hz 150 200 Watts Resolution Included Accessories Quick Start Guide IQ OQ PQ Documentation Desiccant Luer Syringes Filling Nozzles Connecting Fittings amp Tubing NIST Standards Manual 64 K86200 Automatic Density Meter Dimensions xwxh in cm 91 44cm L x 48 26 cm W x 45 72 cm H Shipping Information shipping Weight 70 Ibs 31 75 kg Ordering Information Catalog No Order Qty K86200 Automatic Density Meter Model A 1 K86201 Automatic Density Meter Model B 1 Accessories K86202 21 CFR Part 11 Option K86203 Refractometer Control Module K86204 Heated Interface Attachment K86206 Bar Code Scanner USB K86207 Fluke Hart Thermometer Kit Consists of Handheld Digital Thermometer Temperature Probe and Calibration Certificate K86208 Inkjet USB Printer Kit Includes Inkjet Printer and USB communication cable K86209 Laser USB Printer Kit Includes Laser printer and USB communication cable K86210 40 Column Serial Printer Kit Includes 40 Column Serial RS232 Printer Null Modern Cable and Adapter RUST PROTECTION BY METAL PRESERVATIVES IN THE HUMIDITY CABINET Test Method Tests the ability of metal preservatives to prevent steel panels from rusting under conditions of high humidity Poli
52. fety Valve Out of Range Temperature Visual Alarm Damaged Probe Visual Alarm Electrical Requirements 220 240VAC 50 60Hz Included Accessories Oxidation Software USB Cable sample Holder 6 spacer 4 Dimensions wxdxh in cm 14 6 x 19 4 x 7 6 36 5x48 5x19 Net Weight 36 3 Ib 16 5 kg Ordering Information Catalog No K83100 Oxidation Test Reactor 220 240V 50 60Hz GEE INSTRUMENT niet INC 11 ADDITIONAL ACCESSORIES Additional equipment materials and or reagents are required to perform some of the test procedures in the preceding pages Please refer to the applicable test method for further information or contact Koehler for assistance Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents Pages 42 43 ASTM D611 IP 2 ISO 2977 DIN 51775 FIM 791 3601 Pipets 10mL and 5mL Laboratory Balance Oven Rubber Suction Bulb Safety Goggles Plastic Gloves Aniline Calcium Sulfate or Sodium Sulfate anhydrous n Heptane Air Supply for Automatic Aniline Apparatus Saybolt Color of Petroleum Products Pages 44 46 47 ASTM D156 DIN 51411 FTM 791 101 Acetone or other Solvent Soap Qualitative Filter Papers Distilled Water ASTM Color of Petroleum Products ASTM Color Scale eeeeeesseeeeteeeeees Pages 45 46 ASTM D1500 IP 196 ISO 2049 FTM 791 102 solvent Kerosene for dark samples Distilled Water Distillation of Petroleum Produ
53. g 2 5 9 K27785 8 237 plated brass Metal Seat 27e 5 9 K27781 8 237 stainless steel Viton O ring 2 5 9 K27782 8 237 acrylic Viton O rin 276 5 9 K27770 4 118 plated brass Viton O ring 1 4 7 K27771 4 118 stainless steel Viton O ring 1 4 7 K27772 4 118 plexiglass Buna N O ring 1 4 01 K27760 4 118 plated brass Viton O ring 1 2 8 K27761 4 118 stainless steel Viton O ring 1 2 8 K27762 4 118 acrylic Viton O ring 1 2 8 All Levels Sample Thief Similar to the standard 16 oz 473mL Sample Thief Bacon Bomb but equipped with an adjustable needle valve opening instead of a plunger to control rate of flow during all levels and running sampling from storage tanks Plated brass construction Overall Shipping Length Weight Sample Thief Extension Rods in cm Ibs kg Installs in sample thief plunger assembly 15 38 5 13 5 9 Stainless steel with threaded end 15 38 5 13 5 9 12 30 6 9 4 1 Catalog Length 12 30 6 9 4 1 No in cm Application 12 30 6 8 3 6 K277 EXT1 1 2 5 12 30 6 8 3 6 K277 EXT2 2 5 1 10 25 8 5 2 3 K277 EXT3 3 7 6 32 16 and 10 25 8 5 2 3 K277 EXT6 6 15 2 80z models 10 25 8 5 2 3 K277 EXT12 12 30 5 10 25 8 5 2 3 K277 EXT18 18 45 7 9 s 24 6 4 1 8 K277C EXT1 1 2 5 9 s 24 6 4 1 8 K277C EXT2 2 5 1 9 s 24 6 3 1 4 K277C EXT3 3 7 6 4 oz models 13 33 7 3 1 4 K277C EXT6 6 15 2 13 33 7 3 14 K277C EXT12
54. g springs ball joint clamps connection tubing hose clamps quick connect adapters and fittings for easy connection of jacketed glassware and tubing and vacuum grease Specifications Conforms to the specifications of ASTM D1160 ISO 6616 JIS K2254 Temperature Range Ambient to 425 C 797 F Temperature Display 0 1 C resolution Temperature Accuracy 0 5 C Vacuum Range 0 1 Torr to Atmospheric Pressure 760 Torr Vacuum Display 0 1 Torr resolution Vacuum Accuracy 0 2 Torr External Circulator Temperature Range Ambient 5 C to 150 C Electrical Requirements 115V 60Hz 220 240V 50 60Hz K80300 VDS3000 Vacuum Distillation System Vacuum Pump and Refrigerated Constant Temperature Circulation Bath are not included with the VDS3000 System but are available from Koehler Instrument Company Inc Please refer to Recommended Accessories in the Ordering Information Section for details Side shelf for housing the Vacuum Pump and Circulation bath is also available upon request Shipping Information shipping Weight 120 Ibs Dimensions 15 Cu ft Dimensions wxdxh in cm Cabinet 29 x 9 x 32 75 x 23 5 x 82 6 Control Box 7 x 9 x 9 19 7 x 23 5 24 7 Net Weight Cabinet 62 Ibs 28 2 kg Control Box 21 Ibs 9 6 kg Ordering Information Catalog No Order Qty K80300 VDS3000 Manual Vacuum Distillation System 1 115V 60Hz K80390 VDS3000 Manual Vacuum Distillation System 220 240V 50 60Hz Accessories K80320 VDS
55. h Optional External PC Specifications Conforms to the specifications of ASTM D86 D285 D850 D1078 D4737 D189 Section 10 DIN 51751 ISO 3405 IP 123 IP 195 JIS K2254 NF M 07 002 Electrical Requirements 120V 60Hz 20A 230V 50 60Hz 10A Temperature Distillation Range 0 to 450 C 0 1 C accuracy Condenser 5 to 60 C 0 1 C accuracy closed loop system Receiver Chamber 0 to 60 C 0 1 C accuracy Distillation Parameters Distillation Rate 2 to 15mL min in 0 1mL increments user Selectable Receiver Volume 0 to 100mL 0 01mL accuracy by photoelectric infrared detection of meniscus by level following system utilizing a precision stepper motor and a Special calibrated glass receiver automatic calibration of evaporated loss volume and automatic volume calibration system ensures highest accuracy Barometic Pressure Automatic barometric correction utility with auto matic sensor range 550 to 900 mm Hg 1 mm Hg accuracy Dry Point Detection Automatic dry point detection board is included with standard equipment and only requires a dry point sensor 200mL flask and PTFE plug for ASTM D850 and D1078 tests Environment Operates at 0 to 25 C 113 F Dimensions xwxh in cm Shipping Information 21xX21 5x27 75 53 3x54 6x70 5 Shipping Weight 260 Ibs 95 kg Net Weight 230 Ibs 91kg Dimensions 28 Cu ft 06 Test Method The sample is evaporated and condensed under controlled conditions and obse
56. in an oxygen bomb calorimeter under controlled conditions The heat of combustion is computed from temperature observations before during and after combustion with proper allowances for thermochemical and heat transfer corrections Either isothermal or adiabatic calorimeter jackets can be used Automatic Calorimeter The automatic calorimeter is the latest system for determining gross calorific values of liquids and solid fuels A higher level of automation with extremely simple handling characterizes this device In addition to the Isoperibolic measurement procedure a Dynamic reduced time mode is also available for the user Different working temperatures can be selected for both procedures based on the temperature of the connected water To provide a supply of cooling water the calorimeter can be connected to a standard thermostat or an appropriate permanently installed water connection with a connection valve The unit is equipped with a very convenient operating panel through which operation of the device takes place The graphical display with active back lighting displays the appropriate status messages The temporal course of a measurement that has been started and all current parameters of the weighed in sample can be constantly monitored and are arranged to be clearly visible Connections for analysis scale printer sample rack for identifying and managing samples are already integrated into the basic device The network connection
57. increment value 61 K23050 Salt in Crude Analyzer Electrical Requirements C Shipping Information 115V 60Hz shipping Weight 6 lbs 2 75kg 220 240V 50 60Hz Dimensions 1 5 Cu ft Dimensions xwxh in cm 9x4 25x2 5 23x10 8x6 5 Net Weight 2 lbs 1kg Ordering Information Catalog No K23050 Salt in Crude Analyzer 115 230V 50 60Hz Accessories K23050 9 Mixed Salts Solution 100ml K23050 10 Mixed Salts Solution 500ml Keale INSTRUMENT COMPANY INC WATER AND SEDIMENT DETERMINATION BY AUTOMATIC CENTRIFUGE Test Method Centrifugation provides a convenient means of determining sediment and water content in crude oil fuel oils middle distillate fuels and biodiesel Also used in determining the precipitation number demulsibility characteristics trace sediments and insolubles in used lubricating oils Automatic Heated Oil Test Centrifuge Choice of long short pear or finger rotor assembly to accommodate corresponding centrifuge tubes Accommodates four 4 centrifuge tubes of 6 or 8 conical ASTM types long short pear or finger tubes Automatic control of acceleration ramp centrifugation speed and timing functions 4 LCD Touch Screen Control Panel substantial Insulation for Reduced Heat Loss Precise balancing Quiet Operation Large clear top opening lid Class 1 Division 2 explosion resistant rating Fully automatic bench top centrifuge designed expressly for petroleum testing applicat
58. ion Zonee 250 000 103C ASTM 103C Solvents Distillation 148 to 202 C 250 000 104C ASTM 104C Solvents Distillation WENO 22776 250 000 105C ASTM 105C Solvents Distillation 198 to 252 C 250 000 106C ASTM 106C Solvents Distillation 223 0 2 1 C 250 000 107 ASTM 107C Solvents Distillation 248 to 302 C For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 Ordering Information Catalog No Front View Distillation Apparatus K45000 Right Hand Model 115V 60Hz K45100 Left Hand Model 115V 60Hz K45090 Right Hand Model 220 240V 50 60Hz K45190 Left Hand Model 220 240V 50 60Hz Group 4 Front View Distillation Apparatus K45200 Right Hand Model 115V 60Hz K45300 Left Hand Model 115V 60Hz K45290 Right Hand Model 220 240V 50 60Hz K45390 Left Hand Model 220 240V 50 60Hz Catalog No Type Capacity mL Flasks 332 003 006 A 100 332 003 001 B 125 332 003 002 C 200 332 003 005 D 250 Graduates 332 002 013 A 25 332 002 003 B 100 332 002 014 C 200 Flask Support Boards K45410 A 1 3 18 K45420 B 1 3 81 K45430 C Ziel K45440 D 2 6 98 Miscellaneous K45540 Receiver Cooling Bath Jar 334 002 001 Top Silicone Plug For Type A B amp D Flasks pk 10 334 002 002 Side Silicone Plug pk 10 334 002 003 Top Silicone Plug For Type C Flask pk 10 KL INSTRUMENT Ner INC 99 AUTOMATIC DISTILLATION OF PETROLEUM PRODUCTS K45603 Automatic Distillation Analyzer wit
59. ions Features a 4 LCD touch screen control panel This integrated touch screen can be used to turn the heat on and off set the duration of the test set the RCF RPM values and choose the type of rotor assembly and corresponding glassware to be used during the test The motor Speed mechanism allows the user to simply set the desired speed and the instrument will attain that speed This mechanism calculates RPM based on the given RCF and type of Rotor selected The large clear top opening lid provides for easy access to the rotor and tube holders and for cleaning of the unit The lid has a 18 diameter viewing window allowing the operator to view inside the chamber for checking the status of the rotor and checking for possible spillage of the centrifuge tubes Molded PTFE cushions provide for maximum protection and easy positioning of the tubes Safety Features The Centrifuge comes equipped with a Safety Lockout Mechanism Upon emergency shutdown the door is locked and cannot be unlocked until the unit comes to a complete stop the unit is turned back on and the stop unlock key is pressed on the touch screen display Furthermore the centrifuge cannot Start while the door of the chamber is open and the latch is not engaged The Nitrogen Purge feature allows for a slow release of Nitrogen into the bowl of the centrifuge This feature requires an external Nitrogen Gas source and can easily connect to an Inlet port located at the back of the un
60. ions and observations are made of the temperatures at which various percentages are recovered and or the percentages recovered at specified temperatures Front View Distillation Apparatus e Conforms to ASTM D86 E133 and related ASTM and international standards e Choice of three different models Front View Distillation Apparatus Groups 1 2 and 3 Meets all ASTM and related specifications for distillation of motor and aviation gasolines aviation turbine fuels naphthas kerosenes distillate fuels natural gasoline liquid hydrocarbon mixtures and other petroleum products Consists of fully insulated stainless steel condenser and heater units Heater unit includes flask Support platform viewing window 1250W heater with stepless variable control and rack and pinion heater elevation mechanism with push turn control knob Please inquire about higher wattage heaters White receiving flask background facilitates viewing of fractions during test Available with right hand or left hand heater unit for convenient pairing Includes graduate Support block and flask support boards Group 4 Front View Distillation Apparatus Front View Distillation apparatus designed for testing of Grade No 2 fuel oil Grade No 2 D diesel fuel oil gas oils and other distillates requiring condenser bath temperatures of up to 140 F 60 C Also suitable for gasolines aviation turbine fuels naphthas kerosenes and other liquid petroleum products Similar in features
61. is is calculated as a percentage of the original sample Conradson Carbon Residue Apparatus e Conforms to ASTM D189 specifications A weighed quantity of sample is placed in a crucible and heated to a high temperature for a fixed period The crucible and the carbonaceous residue is cooled in a desiccator and weighed The residue remaining is calculated as a p percentage of the original sample and reported as conradson carbon residue ie Ordering Information Poy Catalog No l Order Qty vane p rr S K80030 Conradson Carbon nizsia Apparatus 1 E iii A a gt Accessories Carbon Residue K80031 Porcelain Crucible Apparatus K80032 Skidmore Crucible with Iron Cover o K80033 Iron Crucible with cover Specifications Included Accessories K80034 Iron Hood with bridge Conforms to the specifications of Porcelain Crucible K80034 WT Nickel Chrome Triangle Wire Support ASTM D189 D6074 ANS Z 11 25 Skidmore Crucible with Iron Cover K80035 Refractory Block IP 13 ISO 6615 DIN 51551 lron Crucible with Cover K80036 Tripod FTM 791 5001 NF T 60 116 Iron Hood with Bridge K80039 Burner Shipping Information Refractory Block Shipping Weight 7 Ibs 3 2kg Nickel Chrome Triangle Wire Support For NIST traceable certified thermometers please refer to the ASTM Thermometer section on Tripod pages 184 through 191 Burner 60 SEDIMENT IN CRUDE OILS AND FUEL OILS BY THE EXTRACTION METHOD Test Method Determines sediment content of crude oil
62. is the temperature at which the solid to liquid phase transition occurs referenced at one atmosphere 1 ATM of pressure e Conforms to BP Appendix 5 Method 6 and GLP specifications e Readily interchanged between automatic and manual detection of melting point ranges e Intelligent Lamp Intensity Control with Soft Start e Storage capacity for up to 20 sample tests e User interactive software and data entry including easy alphanumeric entry of sample name ID number and date e User selectable operating modes AUTO detection mode Start end of melting point range is automatically detected by a photosensing infrared device The melting process is recorded and viewed on screen in real time by a CCD camera MANUAL detection mode Start end of melting point range can be Selected manually with a key press by user Sample melting point can be determined as per BP method by Heat amp Cool temperature function As above the melting process is recorded and viewed on screen in real time by a CCD camera The Automatic Melting Point Apparatus is the latest technology for microprocessor based determinations of melting point ranges of crystalline powdered and polymeric materials and is used to assess sample purity Requires approximately 5mg of sample spread uniformly on a glass slide covered with a glass coverslip The slide is placed on a uniformly heated round furnace and subjected to a heating profile as required by the user Precise
63. it Specifications Conforms to the specifications of ASTM D91 D96 D893 D1796 D1966 D2273 D2709 D2711 D4007 D5546 IP 75 145 359 API MPMS Chapter 10 4 API 2542 2548 ISO 3734 DIN 51793 NF M 07 020 Capacity Four 4 oil test centrifuge tubes long 100mL short 100mL pear 100mL or finger tubes 12 5mL Maximum Speed 2200 RPM Maximum RCF 1327 long 1170 short 865 pear shaped Timer 0 to 999 min Set Speed 200 2200 RPM Speed Readout 0 2200 RPM Temperature Control ambient to 93 C 200 F Temperature Readout Digital Brake Automatic Dynamic Electrical Requirements C 115V 60Hz 10A Dimensions xwxh in cm 23X30X13 51x76x34 Shipping Information shipping Weight 110 Ibs 50 kg 230V 50 60Hz 5A Net Weight 93 Ibs 42 kg Dimensions 11 2 Cu ft K60002 Automatic Heated Oil Test Centrifuge Ordering Information Catalog No K60002 Automatic Heated Oil Test Centrifuge 115V 60Hz with Long Tube Rotor Assembly Automatic Heated Oil Test Centrifuge 230V 50 60Hz with Long Tube RA Automatic Heated Oil Test Centrifuge 115V 60Hz Short Tube RA Automatic Heated Oil Test Centrifuge 230V 50 60Hz with Short Tube RA Automatic Heated Oil Test Centrifuge 115V 60Hz Pear Tube RA Automatic Heated Oil Test Centrifuge 230V 50 60Hz with Pear Tube RA Automatic Heated Oil Test Centrifuge 115V 60Hz Finger Tube RA Automatic Heated Oil Test Centrifuge 230V 50
64. it for melting solid samples such as fats and waxes and preventing from solidification within the cell during testing Dimensions xwxh in cm 7 1X20 3x6 7 19 5x51 5x17 Net Weight 17 Ibs 7 75kg Shipping Information shipping Weight 23 Ibs 10 5kg Ordering Information Catalog No K13150 Automatic Saybolt and ASTM Colorimeter 115 240V 50 60 Hz 46 AUTOMATED COLORIMETER Automated Colorimeter e Touch screen TFI Color Display e Automatic cuvette recognition e Data log for 500 color values 50 color reference values 500 photometric readings 20 wavelength scans 20 time scans Automatic zero calibration program Reference Beam Technology Password protection GLP documentation USB Ports 1 x Type A and 1 x Type B High performance microprocessor controlled spectrophotometer with a wavelength range from 380 to 720 nm for color measurement or 320 nm up to 1100 nm for routine analysis The K13550 can carry out an exact colorimetric evaluation in conformity with several ISO ASTM standards with just a single measurement and display the result in terms of traditional color systems such as lodine Hazen APHA or Gardner color numbers as well as in modern CIE L a b color values Besides the over 20 color indexes transmittance and absorbance can be measured at individual wavelengths so that the K13550 can be used universally for analytical purposes in the laboratory Color measurement methods lodine Hazen APHA Pt Co G
65. lance Rust Protection by Metal Preservatives in the Humidity Cabinet cece Page 65 ASTM D1748 FIM 791 5310 silica Sand Petroleum Naphtha Precipitation Naphtha Methyl Alcohol Air Supply Water Supply Freezing Point of Aqueous Engine Coolant Solution Page 68 ASTM D1177 Glass Wool Solid Carbon Dioxide Liquid Nitrogen
66. larisation End point indication Visual display print out acoustic beep Display 40 character alphanumeric backlit LCD Measuring range possible 1g 100mg water Measuring range typical 1g 10mg water Moisture range 1 ppm 100 Max sensitivity 0 1 ug Max titration speed 2 0 mg per minute Max current 400 ma Drift compensation Automatically controlled Start delay time 0 30 minutes user selectable End delay time 0 30 minutes user selectable Power supply 90 264VAC 47 63Hz Universal input C Precision 10 100ug 3ug 100Ug 1mg 5ug above 1mg 0 5 Calculation modes Weight weight user programmable Weight dilution ratio user programmable Volume density user programmable Volume volume user programmable Display format ug mg kg ppm Print format ug mg kg ppm Statistics max mean min values upto 99 runs Method storage 10 user programmable methods sample ID number user programmable Printer 42 character high speed thermal printer Stirrer speed Microprocessor controlled Dimensions 250 x 245 x 120 mm Weight 3 kg Language English Francais Espanol Portugues Deutsch and Magyar Calendar clock Analysis time and date print out GEE INSTRUMENT niet INC AUTOMATIC FLOCCULATION TITRIMETER Test Method Samples of asphalt or heavy oil or residuum are dissolved in toluene at various concentrations and titrated with iso octane or n heptane at controlled temperatures to det
67. le The Automatic Distillation Analyzer 5000 Series may be ordered for operation with an external PC purchased separately or may be ordered with a built in PC internal touch screen monitor virtual keyboard and mouse An easy to use Windows based PC communication software expands user capabilities for data analysis and unit control Distillation methods and parameters can be easily created or modified Software calculates repeatability and reproducibility as per ASTM D86 as well as Standard and deviation against reference materials Test results are displayed in real time and can include distillation curve and temperature with or without barometric compensation and or evaporation correction distillation rate heating power curve master curve comparison and zoom function for high resolution of heating and temperature curves The heater compartment is rapidly cooled at the completion of a distillation run to reduce operator downtime The analyzers are of rugged construction for instrument longevity with a modular design for easy routine maintenance Receiver Chamber Heating System The receiver chamber heating system is ideal for samples that form waxes or other solids during distillation AUTOMATIC DISTILLATION OF PETROLEUM PRODUCTS Dry Point Detection as Standard Feature Dry point can be detected visually or by automatic detection for ASTM D850 and D1078 test methods The unit is delivered ready with the PC board components already included as
68. m round glass cuvettes K13550 1 Thermal Printer with USB Connection AUTOMATED COLORIMETER FOR SAYBOLT AND ASTM COLOR K13150 Automated Colorimeter Specifications Conforms to the specifications of ASTM D156 D1500 D6045 E 308 JIS K2580 ISO 2049 NF M 07 003 Reproducibility 0 25 T 1 Saybolt value spectral Range 410 710 nm Data Output RS232 printer Light Source tungsten halogen lamp Illuminant CIE Illuminant C Observer 2 Electrical Requirements 115 240V 50 60Hz C Saybolt and Mineral Oil Colorimeter e Conforms to ASTM D156 D1500 D6045 and related test specifications e Designed for color measurement of waxes and other petroleum products High precision spectrophotometer for objective color analysis of petroleum fuels oils waxes and petrochemicals according to the Saybolt and ASTM Color scales Test results can also be displayed in terms of CIE values and spectral data The colorimeter is rugged with a fabricated steel housing which is designed to function equally as a QC instrument within the laboratory or on 24 hour operation in a production environment A diagnostic test routine allows users to conduct periodic checks on the instrument or to identify faults Direct access of the precision filament lamp from outside the instrument allows for easy replacement The colorimeter is also supplied with a colored glass filter of known Saybolt value for regular conformance testing Equipped with integrated heater un
69. meter would be 251 004 01H Certified API Gravity Hydrometer For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 Keale INSTRUMENT COMPANY INC DENSITY RELATIVE DENSITY SPECIFIC GRAVITY OR API GRAVITY Constant Temperature Hydrometer Bath e Holds 12 hydrometer cylinders e Can be used for Reid Vapor Pressure immersion type cylinders e Conforms to ASTM D323 D1298 D6074 D6158 and related specifications A versatile constant temperature bath designed for density gravity determinations of petroleum products at temperatures of up to 195 F 90 C and also for Reid Vapor Pressure determinations using immersion bombs Microprocessor PID control provides quick temperature stabilization without overshoot and the unit is protected by an overtemperature control circuit that interrupts power should bath temperature exceed a programmed cut off point Dual LED displays provide actual and setpoint temperature values in C F Communications software R amp 232 etc ramp to set and other enhanced features are available as extra cost options Contact your Koehler representative for information Also available Special bath to accommodate both ASTM D323 Vapor Pressure of Petroleum Products Reid Method listed on page 93 and D942 Oxidation Stability of Lubricating Greases by the Oxygen Bomb Method listed on pages 152 153 as well as D525 Oxidation Stability of Gasoline Inductio
70. mple cylinder connecting tubing and all necessary valves and couplings K47510 Sample Capillary K47520 Sample Reservoir K47530 Combustion Chamber K47540 Absorber K47550 Spray Trap K47560 Cooling Bulb K47570 Stainless Steel Burner RAMSBOTTOM CARBON RESIDUE OF PETROLEUM PRODUCTS Test Method Determines the carbon residue left after evaporation and pyrolysis of a sample oil in the Ramsbottom furnace providing an indication of the deposit forming tendencies of fuels and guidelines for the processing of refinery products Ramsbottom Carbon Residue Apparatus e Conforms to ASTM D524 and related specifications e Microprocessor temperature control with digital display and overtemperature cut off Thermostatically controlled coking furnace for five samples Cast iron block type furnace reaches the standard test temperature of 550 C 1022 F rapidly and controls with 1 C stability Microprocessor temperature control has C F switchable digital setpoint and display Operator and equipment are protected by an overtemperature control circuit which automatically interrupts power to the unit should block temperature exceed the programmed cut off point Communications software RS232 etc ramp to set and other enhanced features are available as extra cost options Contact your Koehler representative for information Heavily insulated stainless steel cabinet with three layer refractory top provides excellent heat retention Ordering
71. n Method listed on pages 81 82 Please contact a Koehler Customer Service representative for additional information Dimensions Ixwxh in cm 30x14x28 76x36x71 Net Weight 64 Lbs 29 0kg Shipping Information shipping Weight 118 Ibs 53 5kg Dimensions 11 4 Cu ft Specifications Capacity twelve 12 hydrometer cylinders without base or Reid Vapor Pressure one opening type bombs Temperature Range ambient to 250 F 121 C Temperature Control Stability 0 2 F 0 17 C Heater Range 0 2500W Bath Medium 19 gal 71 9L water Electrical Requirements C 115V 60Hz Single Phase 22A 230V 50 60Hz Single Phase 11A Ordering Information Catalog No Order Qty K26400 Constant Temperature Hydrometer Bath 115V 60Hz 1 K26490 Constant Temperature Hydrometer Bath 230V 50 60Hz Accessories K26410 Hydrometer Cylinder 12 Borosilicate glass 15 lx2 dia with 2 lip 250 000 61F ASTM 61F Thermometer Range 90 to 260 F 1 250 000 610 ASTM 61C Thermometer Range 32 to 127 C For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 DENSITY RELATIVE DENSITY SPECIFIC GRAVITY OR API GRAVITY Constant Temperature Hydrometer Bath e Accommodates one standard 2 x15 51x380mm hydrometer cylinder with base e Compact design saves space Thermostatically controlled water bath with 500W copper immersion heater and hydraulic thermoregulator for operation at temperatures of up
72. nt to 200 C 30 C with the use of circulated refrigerated coolant Digital temperature control with temperature uniformity of 0 02 C Built in ice bath for performing ice point calibrations Meets the requirements of NBS Monograph 150 Constant temperature calibration bath for liquid in glass thermometers dial thermometers digital thermometers and other temperature measuring instruments Consists of an oil bath with digital electronic control providing temperature uniformity of 0 02 C in the range 30 C to 200 C Accessory Standard Thermometer is calibrated and certified traceable to NIST standards Turntable rack inserts in bath to immerse six thermometers or temperature probes and the standard thermometer Bath depth of 12 30 5cm accommodates all partial immersion thermometers and most 15 total immersion thermometers Features digital setpoint and display C F switchable of bath temperature for maximum convenience and overtemperature control to prevent accidental overheating Built in cooling coil permits circulation of tap water or refrigerated coolant to permit operation at sub ambient temperatures or to facilitate rapid cool down for multi point calibrations Equipped with drains for oil bath and ice bath Dimensions xwxh in cm 28X24x21 71X61x53 Net Weight 52 Ibs 23 9kg Shipping Information shipping Weight 66 Ibs 30kg Dimensions 8 2 Cu ft Specifications Temperature Range 30 C to 200 C
73. ntries of pH limit values make the data more defined and informative Conductivity Meter Koehler offers the perfect choice of a bench top conductivity meter for measurements in the laboratory whether routine or at the R amp D level The conductivity meter offers better operating comfort and measuring confidence in all areas of application Due to a user selective temperature function the instrument calculates the conductivity at the reference temperature 25 0 1 C with a linear function Conductivity is an important factor in water analysis for quality of drinking water direct ionic concentration measurement in pharmaceutical preparations waste water treatment plants pollution control in lakes amp rivers boiler feed water and oceanography to determine salinity and TDS Specifications Temperature Range 0 to 150 C Temperature Resolution 0 1 C Temperature Accuracy 0 2 C Display 20 x 2 line back lit LCD Keyboard Aphanumeric splash water proof polyester soft keys Output 1 Parallel Port for Printer 1 RS232C for PC Environmental Operating Temperature Ambient to 45 C Relative Humidity 5 to 90 non condensing Electrical Requirements 115V 60Hz 230V 50Hz Dimensions wxdxh in cm 12x8 7x27 6 30 5x22x70 Net Weight 4 85 Ibs 2 2kg 14 Ordering Information Catalog No K90601 pH Meter 115V 60Hz K90691 pH Meter 230V 50Hz K90602 Conductivity Meter 115V 60Hz K90692 Conductivity Meter 230V 5
74. odels K27550 and K2 7560 conform to ASTM D1218 and D1747 maximum temperature 100 C and measures to the fifth decimal place refractive index or one hundredth place in percent solids The K27550 also has a built in data storage system with secure electronic Signature recording The refractometer incorporates numerous innovations designed to improve the accuracy of petroleum product testing A 589 nanometer filter gives true sodium D Line refractive index readings The large graphical LCD is easy to read and provides complete sample analysis documentation including the reading temperature and scale name of the screen set up diagnostic and calibration routines are displayed with easy to follow Step by step instructions User developed customer calibration curves may be programmed allowing automatic temperature correction and direct percent concentration percent reaction completion etc This unit has been used successfully throughout the petrochemical industry Ordering Information Catalog No K27550 Automatic Petroleum Refractometer for D1218 and D1747 110 240V 50 60Hz Includes data storage K27560 Automatic Petroleum Refractometer for D1218 and D1747 110 240V 50 60Hz Accessories K27504 Calibration Fluid Certificate of NIST traceability included K27505 Refractometer Communication Software Package with real time data export into Microsoft Excel 73 K27550 Automatic Refractometer Specifications Measurement Scales Refrac
75. olor by comparing a column of sample against standard color discs The Saybolt Wax Chromometer measures color of non fluid waxes by heating the samples during the test Saybolt and Saybolt Wax Chromometers e Conforms to ASTM D156 and related specifications e Three position color standard turret e Tests non fluid waxes and liquid petroleum products Determines Saybolt Color of highly refined petroleum products Consists of a matched set of sample and standard tube assemblies with optical viewer Compares a sample of the product to be tested against standard color discs under a uniform light source Reduce column height until the Sample field is lighter than the color standard and convert height to saybolt Color using chart on instrument Three position turret on Standard tube permits convenient changing of color disc combinations Accessory Daylight Lamp Cat No K13010 provides standard light source per ASTM specifications For petroleum waxes the Saybolt Wax Chromometer is equipped with heaters to keep waxes that are not fluid at ambient temperature molten during testing Sample tube has a 200W chrome steel strip heater and a hinged cover to maintain even heat distribution An aluminum block heater with 50W cartridge element keeps wax molten in the draincock assembly Accessory variable transformer may be used to regulate the Sample temperature Optical viewer and stand are fully insulated from the heaters Sample tube assembly has heat resi
76. ples e Measures Salts Concentration in the range of 0 to 150 PTB Ib 1000 bbl e Portable for field or laboratory testing with up to 8 hours of continuous operation from internal Ni Cd rechargeable batteries e 18 bit analog to digital converter for high precision e 24Kb RAM dedicated for data storage about 500 test results e Data can be uploaded in a comma delimited format to a PC with easy to use Windows 2000 XP Vista based software via an RS232 serial data port Determines the salt content conductance and temperature of crude oil Samples according to ASTM D3230 and IP 265 specifications Utilizes the latest low voltage synchronous detection technology for conductivity measurements and a high accuracy thermistor array to measure sample temperature Automatically calculates salt concentration directly from acquired temperature and conductivity values Measures conductivity over four ranges 0 2 2 20 20 200 and 200 1500 mS with automatic range Selection Self calibration feature allows operator to adjust for any drift without re entering standard temperature curves Complete data storage of test results which is limited only by the hard drive capacity of external PC Easy to read alpha numeric display shows any four of the following parameters at one time as chosen by the operator salts conductance conductance 25 C pH pH millivolts temperature C or F internal and external battery voltages date time logging ID and ID
77. point is determined spectroscopically and the results are analyzed by the data acquisition system virtually eliminating operator error in the interpretation of endpoints A key benefit to the user is the fact that the asphaltene concentration can be calculated by the software much faster that tradition methods and with more accuracy The utility of the original Heithaus method has been expanded by developing multiple titration schemes The software uses the data from the expanded method to predict the proximity to coke formation during heavy oil distillation Many refiners stop distillation short of coke formation to avoid fouling in distillation equipment tanks and transfer lines The expanded AFT methodology allows the refiner to recover additional distillate without the fear of fouling This attribute of the instrument Should allow up to a 1 2 increase in yields if applied to a process Conversely the added benefit of being able to predict coking tendency would prevent fouling of the process and thus decrease the use of energy in production as well as reduce down time due to having to clean vessels after fouling One of the primary uses of Heithaus values is to predict the compatibility P Index of which oils and petroleum residua or asphalts can be mixed together for shipping processing or in formulations without causing phase Separation This is valuable to the refiner researcher or asphalt jobber who Supplies petroleum asphalts for highwa
78. purity and the qualitative stability in the presence of contaminants High color content normally indicates contamination Anhydride Purity Bath e Conforms to ASTM D3366 specifications e Redundant overtemperature protection circuitry e Microprocessor based temperature controller Electrically heated aluminum block features a microprocessor based temperature controller with overtemperature protection circuitry and a dual LED temperature display The heating unit provides temperature stability heating rates and minimal temperature gradients which exceed ASTM Specifications and is housed in an insulated steel cabinet with a chemically resistant painted finish Up to six samples can be tested at a time using Nessler tubes Visual color comparisons are made against solutions of Platinum Cobalt color standards Please refer to pages 44 47 for Koehler s line of color measurement and comparison instrumentation Ordering Information K56300 Anhydride Purity Bath Catalog No Order Qty Dimensions xwxh in cm Shipping Information K56300 Anhydride Purity Bath 115V 60Hz 1 12x12x21 31x31x54 Shipping Weight 76 Ibs 35 kg K56390 Anhydride Purity Bath 220 240V 50 60Hz Net Weight 65 Ibs 30 kg Dimensions 9 Cu ft K56306 Nessler Tubes 6 Electrical Requirements 115V 60Hz 220 240V 50 60Hz 68 AUTOMATIC MELTING POINT RANGE APPARATUS Automatic Melting Point Range Apparatus Test Method The melting point of a crystalline solid
79. r API Gravity of Crude Petroleum and length 330mm Liquid Petroleum Products by saa ae eles FE ydrometer ravi Hydrometer Method a Catalog No No Range deg 8 251 000 21H 21H 0to 6 ASTM Hydrometers d 251 000 22H 22H 5 to 11 For density relative density specific gravity or API gravity E 251 000 23H 23H 10 to 16 determination of crude petroleum liquid petroleum products ZL BE 251 000 24H 24H 15 to 21 and mixtures of petroleum and non petroleum products For zi El 251 000 25H 25H 20 to 26 density of LPG and light hydrocarbons refer to page 103 z 251 000 26H 26H 25 to 31 saver to the specifications of ASTM E100 291 000 28H 28H 39 to 41 l 251 000 29H 29H 40 to 46 Applicable Test Method Standards 251 000 30H 30H 45 to 51 ASTM D287 D1298 D6074 D6158 251 000 31H 31H 50 to 56 API MPMS Chapter 9 1 IP 160 ISO 3675 DIN 51757 251 000 32H 32H 55 to 61 API Gravity Hydrometers om i BeA Standard temperature 60 F subdivisions 0 1 API 251 000 35H 35H 70 to 76 length 330mm o 251 000 36H 36H 75 to 81 ASTM Nominal 251 000 37H 37H 80 to 86 Hydrometer API Gravity 251 000 38H 38H 85 to 91 Catalog No No Range deg 251 000 39H 39H 90 to 96 251 000 01H 1H to 11 251 000 40H 40H 95 to 101 251 000 02H 2H 9 to 21 251 000 04H 4H 29 to 41 ermometer in boay 251 000 05H 5H 39 to 51 Standard temperature 60 F subdivisions 0 1 API length 251 000 06H 6H 49 to 61 380mm thermometer scale F 0 150 designation L 251 000 07H 7H 59 to 71 30 to 1
80. r Assembly for Finger Tubes K61141 Centrifuge Tube Finger Tube API 2542 62 WATER AND SEDIMENT DETERMINATION IN CRUDE OIL BY CENTRIFUGE Test Method For the determination of water and sediment of crude oil by centrifuge method during field custody transfers This test method is considered the most practical method for field determination of sediment and water Portable Oil Test Centrifuge e Two Models Available Two 2 place 12VDC amp Four 4 place 115 230VAC e Accommodates either two 6 conical centrifuge short tubes or four short cone finger centrifuge tubes model dependent Integrated Tube Holder Pre heater Timer Model Dependent Switchable Temperature Display between C and F Opening in Top Lid for Speed Calibration by Portable Laser Tachometer K60094 eae Portable Heated Oil Test Centrifuge Specifications Conforms to the specifications of ASTM D96 API MPMS Chapter 10 4 API 2542 Ordering Information Test Capacity K60094 Two 2 short cone centrifuge tubes Catalog No K600X5 K600X6 Four 4 short cone or finger centrifuge tubes aad Portable Heated Oil Test Centrifuge 12V DC 40A Sle deal en i entia e ey 00 K60005 Heated Oil Test Centrifuge 4 Place 115V 60Hz emperature Control Ambient to 160 F 1 1 C K60095 Heated Oil Test Centrifuge 4 Place 220 240V 50 60Hz Electrical Requirements 12V DC 40 115VAC 60HZ 220 240VAC 50 60Hz K60005 FT Heated Oil Test Centrifuge 4 Place Finger Tube RA 11
81. rimeter 0 0 0000 ccccccccccscccscssssessecssersreeesseanneenes 76 Automatic Filter Plugging Tendency Analyzer ASTM D2068 76 Oxidation Stability of Foods Oils Fats and Biodiesel Fuels T1 WWW KOEHLERINSTRUMENT COM ANILINE POINT AND MIXED ANILINE POINT OF PETROLEUM PRODUCTS K10200 Automatic Aniline Point Apparatus Ordering Information Order Qty Catalog No K10200 K10290 290 000 33F 250 000 33C 290 000 34F 250 000 34C 290 000 35F 250 000 35C K10210 K10220 Automatic Aniline Point Apparatus 115V 60Hz 1 Automatic Aniline Point Apparatus 220 240V 50 60Hz Accessories ASTM 33F Thermometer Range 36 5 to 107 5 F 1 ASTM 33C Thermometer Range 38 to 42 C ASTM 34F Thermometer Range 77 to 221 F 1 ASTM 34C Thermometer Range 25 to 105 C ASTM 35F Thermometer Range 194 to 338 F 1 ASTM 35C Thermometer Range 90 to 170 C Borosilicate Glass Test Cell with drain Heating Cooling Tube with platinum element For NIST traceable certified thermometers please refer to the ASTM Thermometer section on pages 184 through 191 42 Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents Test Method Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures Equal volumes of aniline and sample or sample plus n heptane are stirred together while being heated at a controlle
82. rmerly ASTM D270 D6074 or ASTM D1265 specifications Sample Thief Bacon Bomb e Obtains bottom samples or samples from any level e Four different capacities e Plated brass stainless steel or acrylic construction e Standard Viton O ring seal e Optional metal to metal seal Obtains samples from storage tanks tank cars and drums When the thief Strikes the bottom of the tank a plunger assembly opens to admit the Sample The plunger closes again when the bomb is withdrawn forming a tight seal Samples can be taken at any depth with the use of a secondary trip line or extension rods may be added for obtaining samples at levels of up to 18 46cm off the bottom Equipped with plunger locking cam for tight closure during transport except for 4 oz 1 dia model Special models include a 4 oz 118mL pencil model for sampling through small diameter pipes and openings and clear acrylic samplers with plated brass plunger and end pieces Modified samplers can be supplied for special applications we invite your inquiries Outside Catalog Capacity Diameter No oz mL Construction Seal 0 D in cm K27700 32 946 plated brass Viton O ring 3 8 6 K27701 32 946 stainless steel Viton O rin 3 8 6 K27790 16 473 plated brass Viton O ring 2 7 K27795 16 473 plated brass Metal Seat 2 7 K27791 16 473 stainless steel Viton O ring 2 7 K27792 16 473 acrylic Viton O rin 2 7 K27780 8 237 plated brass Viton O rin
83. rometers Standard temperature 15 C subdivisions 0 5kg m length 380mm thermometer scale C 20 to 65 designation L 0 to 85 designation M 20 to 105 designation H Catalog No 251 000 300HL 251 000 301HL 251 000 302HL 251 000 302HM 251 000 303HL 251 000 303HM 251 000 304HL 251 000 304HM 251 000 305HL 251 000 305HM 251 000 306HL 251 000 306HM 251 000 307HL 251 000 307HH 251 000 308HH 251 000 308HL 251 000 309HH 251 000 309HL ASTM Thermohydrometer No 300HL 301HL 302HL 302HM 303HL 303HM 304HL 304HM 305HL 305HM 306HL 306HM 307HL 307HH 308HH 308HL 309HH 309HL Density Range kg m 600 to 650 650 to 700 700 to 750 700 to 750 750 to 800 750 to 800 800 to 850 800 to 850 850 to 900 850 to 900 900 to 950 900 to 950 950 to 1000 950 to 1000 1000 to 1050 1000 to 1050 1050 to 1100 1050 to 1100 49 Dimensions Catalog No Construction dia xh K26300 Brass 22X12 64x305mm K26390 Brass 2X5 51x381mm 332 002 011 Glass 2Xx15 51x394mm Not suitable for use with K26400 series baths Calibrated hydrometers and thermohydrometers are available from Koehler with an ISO IEC 17025 and ANSI NCSL Z 540 1 Report of Calibration When inquiring about calibrated hydrometers and thermohydrometers please refer to the catalog number for the corresponding hydrometer jthermohydrometer and replace the middle three zeros in the catalog number with 004 Example 251 000 01H API Gravity Hydro
84. rvations are made of the temperatures at which various percentages are recovered and or the percentages recovered at specific temperatures Automatic Distillation Analyzer 5000 Series e Conforms to ASTM D86 D285 D4737 and related international specifications e Pt 100 RTD probe with automatic temperature calibration system C or F e Windows based software package for PC control with LIMS export capabilities e Automatic determination of initial boiling point IBP final boiling point FPB dry point and barometric and residue corrections e Diagnostic system continuously ensures proper unit performance and user safety Automatic temperature and volume calibration Programmable distillation rate 2 15mL min Ready for distillation groups 1 4 Networking for up to 32 units Powerful CFC free cooling and heating system Receiver chamber heating system up to 60 C Precision level follower system with optical meniscus detector Integrated automatic fire extinguishing system with manual operation override The Koehler Automatic Distillation Analyzer is designed to perform optimal distillation analyses of gasolines fuels oils solvents aromatics napthas kerosenes hydrocarbons and other volatile products to ensure conformity to rigid quality control standards The analyzer automatically performs tests processes results and produces standard reports according to ASTM ISO and related specifications Two Models are Availab
85. shed steel panels are immersed in the sample oil and then suspended in the humidity cabinet for a specified test period Humidity Cabinet e Conforms to ASTM D1748 and FIM 791 5310 specifications Produces a moisture saturated atmosphere with continuous condensation at a constant 120 F 48 9 C for 33 steel test specimens Test panels are Suspended on a rpm rotating stage Air flow and water level control systems maintain required conditions inside the cabinet per Mil Spec and ASTM specifications Air temperature is maintained at 120 2 F 48 9 1 1 C by a digital LCD electronic controller A continuous heater circuit assists the control heater in bringing the cabinet up to temperature prior to testing Overtemperature protection is provided by an adjustable digital thermostat which cuts off power to the cabinet in case of overheating Cabinet interior is stainless steel lined and all interior components are of Stainless steel or chrome plated steel construction Hinged cover consists of two layers of desized cotton cloth mounted on a metal frame Oil and condensate dripping from the specimens are collected in a drip pan and piped to an external drain Ordering Information Catalog No Order Qty Humidity Cabinet K35200 Humidity Cabinet 115V 60Hz 1 K35295 Humidity Cabinet 220 240V 50Hz K35296 Humidity Cabinet 220 240V 60Hz Accessories K35210 Steel Test Panels 33 Soft temper low carbon cold rolled steel surface ground on both fa
86. stant fiber handles Ordering Information Catalog No K13009 Saybolt Chromometer 1 K13100 Saybolt Wax Chromometer 115V 60Hz 1 K13190 Saybolt Wax Chromometer 220 240V 50 60Hz Accessories K13010 Daylight Lamp 1 Meets ASTM D156 and related test specifications for illumination of Saybolt Chromometers Adjustable for correct positioning Standard 60W bulb not included K13020 Whole Color Standard K13029 Half Color Standard K13032 Matched Set of Tubes with Turret Assembly for K13009 Saybolt Chromometer K13033 Matched Set of Tubes with Turret and Draincock Assembly for K13100 K13190 Saybolt Wax Chromometer 279 115 005 Frosted Bulb 60W 115V 1 219 230 002 Frosted Bulb 60W 220 240V ASTM COLOR OF PETROLEUM PRODUCTS Test Method The ASTM color of petroleum products applies to products having an ASTM color of 0 5 or darker including lubricating oils heating oils and diesel fuel oils For products having an ASTM color lighter than 0 5 use the Saybolt Chromometer To determine ASTM color the sample is compared against standard color discs in the Petroleum Colorimeter Petroleum Colorimeter e Conforms to ASTM D1500 specifications single scale 3 field petroleum comparator designed for visual color grading by direct comparison between the sample and colored glass filters housed in test discs conforming to the chromaticity coordinates of ASTM D1500 The sample and two consecutive glasses on the color scale are viewed simul
87. step fashion The Automatic Crude Oil Vacuum Distillation System is a fully automatic crude oil distillation system that complies with ASTM D2892 and D5236 The distillation process is automated from beginning to end minimizing the time needed to operate the equipment Its fully customizable modular design allows for multiple configurations and easy switching from ASTM D2892 and D5236 Please contact your Koehler representative for required method and corresponding flask size and type Semi Automatic Crude Oil Vacuum Distillation System e Highly Automated Minimizes operator time and makes test easier to perform e Complete System Includes all equipment needed to perform a distillation Fully Automatic Functions include Vacuum Control Fraction Collector Condenser Bath Temperature Heat Control of Column Heated Jacket Shut Down at End of Distillation Reflux Ratio and AET Vapor Temperature Calculation Semi Automatic Functions include Heat Control for Boiling Flask Manually Controlled Functions include Measurement of Receiver Volume and Creation of Volume vs Temperature Distillation Curve The Semi Automatic Crude Oil Vacuum Distillation system can come in a wide variety of configurations with single or multiple distillation columns Please contact your Koehler representative for required test method and configuration 94 DISTILLATION OF PETROLEUM PRODUCTS Test Method The sample is evaporated and condensed under controlled condit
88. stillation Temperature Range Ambient to 400 C 752 F Condenser Temperature Range Ambient 5 C to 150 C Vacuum Range 1 00 mmHg to 50 mmHg 0 13 to 6 7 kPa Electrical Requirements 220 240V 50 60Hz Ordering Information Catalog No K87170 Automatic Vacuum Distillation System 220 240V 50 60Hz K87180 Semi Automatic Vacuum Distillation System 220 240V 50 60Hz AUTOMATIC AND SEMI AUTOMATIC VACUUM DISTILLATION OF CRUDE OIL Test Method ASTM D2892 covers the procedure for the distillation of stabilized crude petroleum see Note 1 to a final cut temperature of 400 C Atmospheric Equivalent Temperature AET This test method employs a fractionating column having an efficiency of 14 to 18 theoretical plates operated at a reflux ratio of 5 1 ASTM D5236 covers the procedure for the distillation of heavy hydrocarbon mixtures having initial boiling points greater than 150 C 300 F such as heavy crude oils petroleum distillates residues and synthetic mixtures It employs a potstill with a low pressure drop entrainment separator operated under total takeoff conditions Distillation conditions and equipment performance criteria are specified and typical apparatus is illustrated Automatic Crude Oil Vacuum Distillation System e Ergonomic Design makes the distillation system easy to use with easy access to all components e The Windows based software is intuitive and guides you through the distillation process in a logical step by
89. taneously making it easier to achieve the optimum color match For rapid color grading within predetermined color limits the glass Standards can be set to the two limiting colors so that it is easy to check that the sample is within tolerance The tungsten halogen light source is color corrected to CIE Standard Illuminant C giving constant lighting conditions for color grading regardless of ambient lighting A prism brings the three fields together to aid color grading Specifications Conforms to the specifications of ASTM D1500 D6074 IP 196 ISO 2049 FTM 791 102 Electrical Requirements C 115V 60Hz 220 240V 50 60Hz Included Accessories Glass Color Discs 2 Sample Container 3 Calibration Certificate Shipping Information shipping Weight 5 5 Ibs 2 5kg Dimensions 2 5 Cu ft Dimensions dxwxh in cm 10 5x9x5 25x27x18 Net Weight 3 5 Ibs 1 6kg K13200 Petroleum Colorimeter with K13210 Sample Containers 3 Included Ordering Information Catalog No Order Qty K13200 Petroleum Colorimeter 115V 60Hz 1 K13290 Petroleum Colorimeter 220 240V 50 60Hz Accessories K13210 sample Container K13223 Replacement Tungsten Halogen Lamp 12V 20W VISUAL EXAMINATION OF USED ELECTRICAL INSULATING OILS Visual Examination of Used Electrical Insulating Oils of Petroleum Origin in the Field Test Method Provides an estimate of the color and condition of in service oils by visual observation and comparison with AS
90. tive Index RI BRIX sucrose Temperature Corrected RI Temperature Corrected BRIX Ten User Programmable Scales Illumination 589nm light emitting diode with interference filter estimated life 100 000 hrs Range Dissolved Solids 0 to 95 solids Refractive Index 1 29000 to 1 70000nD nD Sodium D Line Refractive Index Readability standard Mode 0 1 Solids 0 0001nD Extended Mode 0 01 Solids 0 00001nD Precision standard Mode 0 02 Solids 0 00002nD Extended Display Mode Refractive Index Standard Oils 0 00002 Typical clear aqueous samples Solids Temperature Compensated as sucrose 0 02 Calibration Fluid refractive index standard oil NIST traceable nominal value 1 495 RI 67 61 BRIX sample Types Transparent translucent or opaque Prism Assembly Stainless steel synthetic sapphire sealed with Solvent resistant epoxy Calibration 1 point Water only 2 point Water and refractive index or Brix standard Electrical Requirements 110 240V 50 60Hz Dimensions xwxh in cm 15x10x42 39 x254x1 1 Net Weight 23 Ibs 10 kg Shipping Information shipping Weight 30 Ibs 14kg Dimensions 5 Cu ft Cauler CALIBRATION OF LIQUID IN GLASS THERMOMETERS Thermometer Calibration Bath Calibrates thermometers temperature controllers and other temperature instruments against a factory certified thermometer traceable to NIST standards Verifies accuracy of routine thermometers For temperatures between ambie
91. uage display and print out Integral high speed thermal printer Small footprint Automatic Compensation of Errors The AKF5000 offers new standards in versatility and ease of operation Providing fast accurate and reproducible determinations of water content in liquids gases and powders This easy to use titrator incorporates many state of the art features Designed to be equally suitable for meeting the routine needs of the Quality Control laboratory or the more demanding and varied requirements of research applications Hard copies of results are provided by the built in high speed thermal printer along with statistics data input parameters sample ID numbers and time date of analysis Ordering Information Catalog No K90365 AKF5000 Compact Coulometric Karl Fischer Titrator 115 240V 50 60Hz Included Accessories Glassware pack comprising twin port titration vessel detector electrode generator electrode dessicant tube molecular seive stirrer bar injection septa funnel amp 1ml glass syringe with luer needle Accessories K90365 7 Gas Analysis Kit Comprised of gas inlet gas outlet seal ring amp cap K90365 8 Carry Case K90365 20 Formula Reagent Kit Pack of 8 x 100ml anode reagent 8 x 5ml cathode reagent K90365 35 Water Standard 0 1 mg ml 5ml pk 10 K90365 36 Water Standard 1 0 mg ml 5ml pk 10 01 Specifications and Features Titration method Coulometric Karl Fischer titration End point detection AC po
92. us applications in different fields The liquid path is comprised of Teflon tubing a Teflon lined valve and gas tight burette with a Teflon plunger head It creates a chemically inert system for any Sensitive analysis The instrument is supplied with high speed vortex stirrer with digital speed indication This specially designed stirrer provides excellent homogenous mixing of samples An optional magnetic stirrer is also available Ordering Information Catalog No K90500 Automatic Potentiometric Titrator 115V 60Hz K90590 Automatic Potentiometric Titrator 230V 50Hz Accessories K90500 1 Karl Fischer Titrator Burette Assembly K90500 2 Filter Desiccant Dryer Tube K90500 3 Magnetic Stirrer with Holding Ring K90500 4 Magnetic Stirrer with Electrode Arm K90500 5 Vessel Heating Cooling Accessory K90500 6 pH Checker 19 e oS a eT tnem k90500 Automatic Potentiometric Titrator Specifications Conforms to the Specifications of ASTM D664 D2896 D3227 D4739 Principle Volume determination by equivalence point end point or pH STAT Control Microcontroller based mV range 3200 mV Accuracy 0 1 mV 0 0016 pH Amplifier input impedance gt 10 ohms Burette Resolution 1 5000 for 5 ml 1 10000 for 10 ml 1 5000 for 25 ml Filling time Less than 20 seconds Keyboard Alphanumeric splash waterproof polyester soft keys Display 40 x 2 line back lighted liquid crystal display LCD Titration Head Manual stand
93. with swiveling arm stirrer System Microcontroller based variable speed high torque vortex stirrer with digital indication Magnetic Stirrer optional Sensors Electrodes for Potentiometric titration pH lon Redox Argentometric a Any combination electrode b Differential Electrode System comprising sensing Indicator Electrode with BNC Connector and Reference Electrode with 4mm Banana Connector Electrode for KF Voltametric titration with BNC TNC Connectors Temperature sensor PRT PT100 Calibration 3 point Calibration with user entered buffer values and standardization with 7 pH buffer End Point detection a Potentiometric b Voltametric c Thermometric and Photometric Cut off criteria a Volume b End point Methods Titrations a Acid base b Nonaqueous c Redox d Preciptiation e Complexometric f back titration KF titration Optional Results a Molarity b Assay wt c volume ml d ppm e mg l f mg g g g l h meq l i mol kg j TAN and TBN for oil samples Method Storage 50 methods with parameters Titrant Molarity storage 20 values Input Output Peripheral Interface a Parallel Port 1 for printer b Serial Port 2 for Balance amp PC Electrical Requirements 115V 60Hz 230V 50Hz c mV pH Keale INSTRUMENT COMPANY INC HEAT OF COMBUSTION OF LIQUID HYDROCARBON FUELS BY BOMB CALORIMETER Test Method Heat of combustion is determined in this test method by burning a weighed sample
94. y and roofing applications because it ensures that compatible asphalt blends are supplied Incompatible asphalts show early failure in both applications Coking Index US Patent 6 773 921 Stability also influences coke formation in the refining process Another major use for the AFT is to acquire the data needed to employ the Coking Index The Coking Index is a quantitative measure of the proximity to coking fouling during visbreaking distillation transfer and storage of heavy oil This allows the petroleum refiner to optimize heavy oil processing and to recover the maximum amount of distillate and to stop the processing before fouling occurs Solubility Parameter The solubility parameter at which asphaltenes begin to precipitate and the solubility parameter of the whole oil can be calculated from the AFT data 92 K47100 Automated Flocculation Titrimeter Specifications Conforms to the specifications of ASTM D6703 Temperature Range 20 to 100 C Electrical Requirements 115V 60Hz 220 240V 50 60Hz Included Accessories External Desktop PC with Data Acquisition Software Fiber Optic Spectrometer with Multi Bandpass Detector High and Low Flow Rate Metering Pumps Magnetic Stirring Plates Programmable Circulator with External Probe to Monitor Jacket Temperature of the Sample Reaction Vessels Quartz Flow Cell with Temperature Stability Feature Glassware Thermometer Probes Digital Variable Sample Circulator with