Home
XCGSM Data Sheet/Manual PDF
Contents
1. E phonon o O ofo 0 GSM GPRS CELL MODEM o 000 Lo Figure 1 Figure 4 Figure 5 dij F i re ign XCGSM E LON O Nae 1 Caution The expansion and main circuit boards contain static sensitive components Before handling the cards discharge static charges from your body by touching a grounded bare metal object Ideally handle the cards at a static controlled clean workstation Also handle the cards by the edges only Dirt oil or other contaminants that may contact the cards can adversely affect circuit operation Warning Risk of Danger Be sure to remove all power before removing the expansion port cover XCGSM Figure 2 Figure 3 THE OPTION CARD LABEL Place the option card label on your outer plastic cover of the Modular Controller Master or Data Station Plus The label displays the FCC ID of the particular modem being used in the XCGSM card POWER SUPPLY REQUIREMENTS NEW AND EXISTING INSTALLATIONS The XCGSM option card draws all of its power from the main board of the Modular Controller Master or Data Station Plus The specifications of the Modular Controller Master or Data Station P
2. customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls Europe Printerweg 10 NL 3821 AD Amersfoort Tel 31 0 334 723 225 Fax 31 0 334 893 793 India 54 Vishvas Tenement GST Road New Ranip Ahmedabad 382480 Gujarat India Tel 91 987 954 0503 Fax 91 79 275 31 350 Red Lion Controls China Unit 101 XinAn Plaza Building 13 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688 Fax 86 21 6113 3683
3. CIFICATIONS 1 POWER REQUIREMENTS 24 V 125 mA max Power is supplied to the option card from the main board of the Modular Controller Master or Data Station Plus 2 ANTENNA CONNECTOR SMA Female connector requires 50 Ohm antenna with SMA male connector Quad band antenna 850 900 1800 1900 MHz for global support Dual band 850 1900 MHz antenna for US and Canada only Dual band 900 1800 MHz for Europe only The antenna cable should be 50 impedance RG178 U or RG174 U type and be able to connect to the RSMA Male jack bulkhead The antenna could be horizontal vertical or right angled Longer antenna cable would equate to signal loss This device is intended for connection to an antenna mounted within the building or a UL certified enclosure suitably rated for application 3 CERTIFICATIONS AND COMPLIANCES Refer to main unit manual or Agency Approvals section of Red Lion s website for agency certifications ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Reference Modular Controller Master or Data Station Plus unit for EMC specifications The XCGSM option card has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules 4 ENVIRONMENTAL CONDITIONS Refer to the specifications of the Modular Controller Master or Data Station Plus you are installing this card in 5 CONSTRUCTION For indoor u
4. free Crimson 2 0 software SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller A ORDERING INFORMATION DESCRIPTION XCGSM GSM GPRS Cell Modem Option Card Quad band GSM GPRS Cellular antenna CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit PART NUMBER XCGSMO000 G3QANT00 SFCRM200 SFCRM2MC SFCRM2 Crimson 2 0 with G3 Data Station Manual SFCRM2 Crimson 2 0 with Modular Controller Manual 2 1 G3QANT00 is a 6 inch direct mount Quad band antenna 2 Use these part numbers to purchase Crimson 2 0 on CD with a printed manual USB cable and RS 232 cable Otherwise download free of charge from www redlion net CONFIGURED USING CRIMSON SOFTWARE INSTALLS INSIDE A DATA STATION PLUS OR A MODULAR CONTROLLER INSTALLATION AND CONNECTION HARDWARE ARE INCLUDED WITH CARD CONTENTS OF PACKAGE XCGSM option card This hardware bulletin SPE
5. lus account for the power needs of an option card SOFTWARE UNIT OPERATION CRIMSON SOFTWARE Crimson 2 0 software is available as a free download from www redlion net or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the web site and updating your copy is free CONFIGURING A XCGSM OPTION CARD The XCGSM is configured using Crimson software Crimson is available as a free download from www redlion net or it can be ordered on CD Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the XCGSM using the latest version of Crimson 2 0 you are assured that your unit has the most up to date feature set Crimson 2 0 software can configure the XCGSM through the option card selection After choosing the Cellular Modem option card it is set up as a PPP Modem client PPP Modem server or SMS via GSM Modem All XCGSM option cards are configured to US GSM GPRS frequency band 850 1900 MHz by default During setup of the Cellular Modem Option card the appropriate GSM GPRS frequency band must be chosen depending on the geographical location of the Modular Controller or Data Station Plus Once the option card is configured through Crimson software it needs to be downloaded to the Modular Controller Master or Data Station Plus The Modular Controller Master or Data Station Plus with the XCGSM option ca
6. rd needs to be power cycled for the configuration changes with respect to the GSM GPRS frequency band to take effect Additional information can be found in your Modular Controller Master or Data Station Plus hardware bulletin and the Crimson 2 0 user manual SIM CARD INSTALLATION amp DETAILS A SIM Card has to be installed on the XCGSM option card before installing the option card in the Modular Controller Master or the Data Station Plus TROUBLESHOOTING YOUR XCGSM OPTION CARD If for any reason you have trouble operating connecting or simply have questions concerning your new XCGSM option card contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel 1 717 767 6511 Fax 1 717 764 0839 LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The
7. red lion Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No XCGSM A Drawing No LP0782 Released 02 10 MODEL XCGSM GSM GPRS CELLULAR MODEM OPTION CARD FOR DATA STATION PLUS AND MODULAR CONTROLLER GENERAL DESCRIPTION The XCGSM option card allows the user to add GSM GPRS cellular modem capability to their Data Station Plus or Modular Controller GSM GPRS is the most prevalent cellular technology in today s markets GPRS can be used for services such as Wireless Application Protocol WAP access Short Message Service SMS and for Internet communication services such as email and World Wide Web access The XCGSM modem option card is quad band allowing it to work in frequencies across the Americas Europe and Asia US and Canada work in the 850 1900 MHz bands while Europe Middle East Africa and most of Asia work in the 900 1800 MHz GSM GPRS frequencies The XCGSM requires the addition of a SIM Subscriber Identity Module card which is inserted into the holder prior to installation of the XCGSM card The SIM card securely stores the service subscriber key IMST used to identify a subscriber and is used to connect to the network to obtain an IP address from the provider The XCGSM communication card is easily installed by removing the blank expansion port cover of your Modular Controller or Data Station Plus and plugging the XCGSM card into the expansion port Configuration is simple using Red Lion s
8. se only Installation Category II Pollution Degree 2 6 INSTALLATION REQUIREMENTS See Installing the XCGSM Option card for more details 7 WEIGHT 3 2 oz 94 64g INSTALLING THE XCGSM OPTION CARD The first step is to buy a SIM Card from one of the GSM GPRS providers and insert it into the SIM Card slot of the option card The SIM Card slot is the rectangular slot on top of the GSM GPRS Cellular Modem in the XCGSM option card as shown in Figure 1 See SIM Card details in the Software Unit Operation Section for more details Remove power from the unit 2 Insert a flat bladed screwdriver into the slot at the top of the expansion port cover Gently apply pressure on the screwdriver in an upward direction until the expansion port cover disengages from the unit as shown in Figure 2 Verify that the option card knobs are in the unlocked position as shown in Figure 3 4 Carefully insert the option card into the expansion port opening while aligning the card edge connector on the option card with the main board s header as shown in Figure 4 Once aligned gently press on the front of the card until it is flush with the front of the case Turn the option card knobs to the locked position as shown in Figure 5 w n me B sN i KA