Home
USER MANUAL
Contents
1. i I ZORD 4 Electric Fence Energizer USER MANUAL WIZORD 4 ELECTRIC FENCE ENERGIZER STATUS Power on O ct service WIZORD 4 USER MANUAL Table of Contents INTRODUCTION e A 3 COMPANY PROFI LErni Acan ai 3 GUARANTEE 4 STANDARD OPERATING PROCEDURES aiecscaciscnsticdistvadstivedstiaasnennnstaevedes 5 STANDARD OPERATING PROCEDURES 6 STANDARD OPERATING PROCEDURES 65 7 FEATURES amp FUNCTIONS 5 ire a 8 9 WI ZORD 4 INTRODUCTION Thank you for choosing our product NEMTEK Electric Fence Energizers are designed and manufactured to provide many years of reliable use if installed and maintained correctly The guidelines provided in this manual will assist you with the basic operation and maintenance of your WIZORD 4 The WIZORD 4 is designed and manufactured in South Africa for the international market More information on our products SABS test reports and general information is available our site http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team des
2. The unit has been tested to comply with the latest international requirements CISPR14 2 1997 REMOTE KEY SWITCH The energizer can be wired to a remote on off switch There is only one external input and the selection of gate or remote on off is exclusive EARTH LOOP MONI TORI NG For additional security the facility to use earth loop monitoring is provided for EXTENDED OPERATION DURING MAINS FAILURE The unit detects the mains failure and reduces the fence output energy AUXILIARY 12VDC OUTPUT A 12 Volts DC fused output is available to supply any auxiliary equipment like a radio remote receiver The current must not exceed 0 5 amps Features amp Functions WI ZORD 4 GATE I NPUT Gate delay entry of four minutes or immediate entry alarm SIREN OUTPUT 12VDC output for siren available STROBE OUTPUT 12VDC output for strobe light available WEATHER PROOF HOUSING The unit enclosure is made of high quality weather resistant material ARMED RESPONSE RADIO CONNECTABLE The system has the facility to be connected to an armed response radio BATTERY BACKUP The unit is supplied standard with a 12V 7AH rechargeable battery UNIT UPGRADEABLE The unit can be upgraded to allow High amp low voltage fence monitoring Multiple keypad amp pin numbers Energizer synchronization Programmable fence voltage Programmable gate delay Programmable fence delay VVVVVV 27 9 06 Rev 1 4 Features amp F
3. If it is lit due to an obvious condition such as prolonged mains failure simply turn the unit off and on again Should the condition persist refer to your installer The unit has built in diagnostics to assist the installer Standard Operating Procedure WI ZORD 4 NOTES The energizer will under normal conditions provide the fence with a pulse at the rated energy level Should a mains failure occur the energizer will automatically switch to a reduced energy level This enables the unit to operate without mains for extended periods of time i e with a good battery the unit should be able to operate for approximately twenty hours Batteries should be checked on bi annual basis A functional energizer will only turn itself off under two conditions namely prolonged mains failure where battery damage has occurred or abnormal heat being generated within the energizer There no user serviceable parts within the energizer Please refer all problems to qualified service personnel It is possible that under mains failure conditions the energizer will operate at reduced energy levels and the fence status display will not be fully lit The mains should be restored first before checking the physical fence condition Keep the fence clear of vegetation and do a periodical check for any Slack fence strands etc Standard Operating Procedures Notes WIZORD 4 Standard Operating Procedures LED s Th
4. e opening time exceeded the entry delay period but is now closed If the gate indication LED is flashing the gate is still open ALARM INDI CATION The fence and gate inputs are configured to trigger external alarms and the internal buzzer The service condition will activate the buzzer only Be aware that should there be a prolonged power failure the battery may run low and cause the service light to flash If the mains interruption is sufficiently long the unit will shut down and there will be no indication of mains failure TOGGLE FUNCTION In the event of the unit being switched off by the plastic tab while a fault is active the unit will silence all alarms On turning the unit on again the corresponding LED s will indicate the fault but no alarm outputs will be triggered This provides the user with the facility to leave the unit on if no service personnel are available Should the unit be turned off and on again the alarm outputs will activate after the default periods On turning the unit off again the outputs will again be disabled Users must be wary of this toggle function The user does not need to concern them self with the toggle function if the unit is switched off and on again under normal conditions as per table 1 No alarm condition active BUZZER The buzzer has a different cadence for the fence alarm and gate alarm SERVICE NDI CATION The service indicator should remain off during normal operation
5. e status of the energizer and the fence is displayed on the lt oa front panel of the energizer as follows mi Under normal operating conditions ee 5 oF Power Mains present battery charging Fence energized FENCE cate No gate alarm SERVICE No fence alarm No service condition GOOD If all are flashing fence is operating correctly Conditions that if ignored will sound the alarm Restore mains see Note 1 ON Turn energizer on see Note 2 FENCE Alarm condition iii Alarm condition PE Possible installer intervention required see Note 3 coop Check later see Note 4 Concern see Note 4 Service fence see Note 4 Service fence Alarm Fence faulty O LED OFF LED PERMANENTLY LIT Fault LED FLASHING Fault still accirrad hiit ic naw anna nracant WI ZORD 4 FEATURES amp FUNCTIONS I NTEGRATED UNIT For energizers designed from a security perspective the fence monitoring is an integral part of the product The energizer is an integrated energizer battery charger and fence monitor with a siren and strobe light output LIGHTNING PROTECTION The mains and high voltage outputs are protected against lightning and power surges It also protects the unit against abnormally high potential differences between the high voltage and mains ground I NTERFERENCE SUPPRESSION LOW EMI RADIATION
6. es NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are 10 Tech Manufacturing Pty Ltd s sole liability and the buyer s sole and exclusive remedies for breach of guarantee 10 Tech Manufacturing Pty Ltd shall not be liable for any special incidental consequential direct or indirect damages whether based on contact tort or any other legal theory The foregoing guarantee is in lieu of any and all other guarantees whether expressed implied or statutory including but not limited to warranties of merchantability and suitability for particular purpose WI ZORD 4 STANDARD OPERATION TURNING YOUR UNIT OFF In the default state the energizer can be turned on or off by holding the plastic tab over the corresponding logo on the fascia of the unit The unit will beep once when turned on and twice when turned off FENCE STATUS I NDI CATION The unit will indicate that a condition is currently active fence fault gate open or service condition if the corresponding LED is flashing eg if the fence LED is flashing the fence voltage is currently not satisfactory If the fence alarm indication LED is lit continuously there was a fence alarm condition previously but the fence voltage is now satisfactory Similarly if the gate alarm indication LED is lit permanently the gat
7. igning and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to international standards in order to ensure the highest quality products and continuous customer satisfaction Introduction amp Company Profile WI ZORD 4 Guarantee GUARANTEE The WIZORD 4 energizer manufactured by 10 Tech Manufacturing Pty Ltd is guaranteed for a period of one year from date of sale against defects due to faulty workmanship or materials 10 Tech Manufacturing Pty Ltd will at its discretion either repair or replace a product that proves to be defective 10 Tech Manufacturing Pty Ltd guarantees that the product when properly installed and used in line with the specification as determined by 10 Tech Manufacturing Pty Ltd from time to time will execute its function of generating a suitable potential 10 Tech Manufacturing Pty Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free Faulty units must be returned to Nemtek Units 4 amp 5 64 Vervoer Street Kya Sand Randburg Gauteng South Africa OR Nemtek Security Warehouse Unit 4 Meadowdale Park Cnr Herman amp Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee do
8. unctions Cont d
Download Pdf Manuals
Related Search
Related Contents
Bediengerät KTP400 Basic, KTP600 Basic, KTP1000 Basic, TP1500 USB Share Switch UH821, UH822, UH841, UH842 anleitung personenlifter sito - Sanitätshaus Burbach + Goetz REVO® LOW PROFILE INSTRUCTION MANUAL a freecomm 600 Set DE/EN User's Manual - Van Mechelen Qware DSI3119 game console accessory DeLOCK 91687 card reader Lenovo ThinkPad T520 Viking VICU266-6B User's Manual Copyright © All rights reserved.