Home

USER MANUAL LL PRO WASH IP65

image

Contents

1. Mechanical mounting of LL PRO WASH IP65 and Adjustable bracket The installation of LL PRO WASH IP65 and Adjustable bracket is easy It is not necessary to open the fixture before the mechanical mounting Adjustable bracket 2 1 Fit the adjustable bracket on the fitting and fit with srews AIMING POSSIBILITY The fixture could be aim to wish position with the bracket 2 2 The bracket fix to the solid surface with srews minimal 4pcs Order code Product name LL35 070 LL PRO WASH RGBAW 200 FIX 25 IP65 LL35 090 LL PRO WASH RGBAW 600 FIX 25 IP65 LL35 100 LL PRO WASH AW 200 FIX 25 IP65 LL35 120 LL PRO WASH AW 600 FIX 25 IP65 Accessories LL37 910 LL BARNDOOR PRO WASH 600 Optional 10 40 EL Eliptical 15 x90 AS Asymetrical on request If you have any question please contact su leaderlight sk
2. Dip2 On future Dip2 On future 04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION Pernament use limitations for heating dissipation of LL PRO WASH RGBAW body temperature must be less then 55 C 40 C ambient temperature 30 C ambient temperature 20 C ambient temperature Black version 30 20 of total power 10 of total power 0 of total power Silver or White version 50 Example Then final pernament value for BLACK colour and 40 C ambient temperature 30 20 56 max 143 2 R G B W tA 5 It s mean average of power go inside the fixture at DMX signal Example black LL PRO WASH 1802 R G B W tA 5 Silver or White LL PRO WASH 128 2 R G B W A 5 Value for R or G or B or W or A is 100 256 8bit levels RED 50 128 value RED 75 192 value Final information we don t drop down each colour power with temperature control to get maximum for each colour under total recomMendations therefore you need setup limitations from control desk INSTALLATION SPACE Ventilation space 180 free Ainimal Ventilation space 90 free 100m ae minimal 200mm E J a 3 minimal minimal 100mm 100mm Minimal mounting distance from surface 1 1 Non minimum distance and or non use the original brackets is at your own risk X IA
3. 15 2ch Dip2 On Mode 4 6 2ch Dip3 Oft standard curve Dip3 On 05 MAINTENANCE To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coveredby warranty Regular cleaning is demand dust dirt Maintenance policy ultraSoft curve Unplug mains before maintenance and at least 10 minutes cool off Appliance do not illegal open or demount Clean up dust only from outer surface for ex scuttle diffuser and lenses Use vacuum or dumpy duster warm water Before reinstalling to check failure free state no wet parts Ay Red 1 WASH 200 RGBAW Mode1 Dip1 Off Green 1 Blue 1 Amber 1 White 1 Red 1 Mode2 Dip1 0n Green 1 Blue 1 Amber 1 White 1 Master Strobo 1 19Hz Functions DipBCD rotating switch RS1 100 RS2 10 RS3 1 DipBCD 000 DMX address 001 DipBCD 001 512 DMX address 001 512 DipBCD 9xx AutoTest Fade Over RGBAW DipBCD 8xx AutoTest all channels on 50 DipBCD 7xx AutoTest all channels on 100 DipBCD 6xx AutoTest White on 100 Functions Dip switch Dip1 Dip2 Dip3 Dip4 Dip1 On add 2 channels Master Strobo Dip4 Off activation Standard curve Dip4 On activation UltraSoft curve Dip2 Off future Dip2 Off future
4. This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation 03 3 Connecting to AC power Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables figure 2 1 2 2 Hairbreadth from combustible materials is 0 5m To tackle all Safety Information 01 A For protection from electric shock the device must be grounded earthed It is not necessary to open the fixture before power supply Power supply is solved simple with 1m cable The fixture is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 260V Cord plug connections Wire Colour Screw US L live brown yellow or brass N neutral blue silver a ground earth yellow green green 03 4 Control data connecting Control data cable length is specified by Norm IEC929 Annex E4 It is not necessary to open the fixture before connecting of DMX512 control signal Interconnections are realized by 1m cables In Out with XLR5pin Pin connections Pin 1 ground Pin 2 signal negative Pin 3 signal positive If you have any question please contact su leaderlight sk 03 5 DMX channels subject to chan
5. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LEADER LIGHT LL PRO WASH IP65 LL35 070 LL35 090 LL35 100 LL35 120 COMPLIMENTS ON YOUR PURCHASE All dimensions are in milimeters 630 i 230 130 7 mz 107 5 Following items are included LL PRO WASH IP65 with 1m power cable 2x1m control cable with XLR5pin 1 pc User manual 1 pc Additional items needed Controller compatible with DMX 1 pc Mounting accessories as necessary Surface mounting Screws and washers M12 or M8 Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 02 2 Back panel 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connecting to AC power 03 4 Control data connecting 03 5 DMX channels 04 PERMANENT USE LIMITATIONS 05 MAINTENANCE ENVIRONMENT K E Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMX Leader Light All right reserved 01 SAFETY INFORMATION WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professiona
6. ge The latest version of DMX channels appendix are on the websites www leaderlight eu DMX channels and DIP Switch WASH 600 RGBAW Ch Mode1 Dip2 Red 1 2 3 WASH 600 AW Amber 1 2 3 Green 1 2 3 Blue 1 2 3 White 1 2 3 Master Dip1 On Dip4 Off Amber 1 2 3 Strobo Dip1 On Dip4 Off White 1 2 3 Master Dip1 On Dip4 Off Strobo Dip1 On Dip4 Off Red 1 Mode4 Dip2 0n Amber 1 Green 1 White 1 Blue 1 Amber 2 Amber 1 White 2 White 1 Amber 3 Red 2 White 3 Green 2 Master Dip1 On Dip4 Off Blue 2 Strobo Dip1 On Dip4 Off 2 3 4 5 6 A 8 9 OoOIoINIOI a AJOIN Amber 2 oO White 2 oO Red 3 z N N Green 3 oO Blue 3 w A N Amber 3 D z ol White 3 ak ol O a4 O Master Dip1 On Dip4 Off N N Strobo Dip1 On Dip4 Off Extention and control functions Dip4 0ff Dip1 0ff gt DipBCD use rotating switch for DMX start address RS1 100 RS2 010 RS3 001 from 001 to 511 Dip4 0ff Dip1 0n address 2channel Master Strobo Dip4 On Dip1 Off Dip4 On Dip1 On function switch on AutoRun table functions 100 Prq 0 9 10 Step Time 1 FadeTime switch all channels on 50 test Dip2 Off Mode 1 5 2ch Dip2 Off Mode 1 2 2ch Dip2 On Mode 4
7. l in accordance with relevant local codes A 01 1 Risk of eyes damage Do not look directly into LED lamps Do not look into light beam from a distance of less than 40 cm 16 inches 01 2 Protection from electric shock Shut down power before installation or maintenance Luminaries and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local building and electrical codes to use way damaged wet or if they are overheating warranty Appliance always connect to earth eltech 01 3 Fire prevention Follow all safety consideration Thermostatic switches or fuses never to bypass Do not use or do not connect the products if the power cable power plug or fixtures are any Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the Before removing or installing any cover or part of appliance disconnect it from AC power A Device never shield Around the axis of the fitting 180 must be maintained space for coo ling Minimum distance from the surrounding objects must be 100mm 4 in figure 1 1 LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F surface Luminaries never use without mounting brackets The housing never install directly to the WARNING Non minim
8. um distance and or non use the original brackets is at your own risk 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type 22 66 x RGBAW P4 22 66 x AW P4 Lifetime Long 50 000 hrs 70 degradation Optic Standard 25 on request 10 40 EL and AS Control data Input DMX 512 In Out with 1m cable with XLR5pin Input power max 34W 102W Power connection 100 260V AC 50 60Hz In 1m cable Net weight 3kg 5 5kg IP IP65 Ambient temp Ta max 40 C Cooling Conventional Materials and finish Housing powder painted anodized aluminium in black other colours on request Installation Surface mounting P4 M R Red I G Green M B Blue M A Amber __ W White 6300 K Edition A 2010 02 2 Back panel Detail A 1m cable after unscrew the top cover 100 260V AC 1m cable XLR5pin Top cover In Out DMX512 Detail A Control LEDs O O POWER DATA Dip options 100 10 1 Rotating DIP address 000 511 Control LEDs Indication POWER DATA LED INDICATION STATUS POWER Green blinking 2Hz OK inside fixture is everything correct DATA Yellow light off NO DMX512 signal DATA Yellow blinking 4Hz OK income correct DMX512 signal DATA Yellow fast blinking NON correct digital signal POWER Green DATA Yellow Autotest function alternate blinking 03 INSTALLATION 03 1 Unpacking Unpack carefully