Home

user_manual_motorfok

image

Contents

1. Leica Motor Focus System User manual Manuel d utilisation Gebrauchsanweisung Manual de empleo Jfeica Contents Description 2 530 202 4212 ia HR REI dex bendezis 4 Safetyiconcept rind nn ak 4 Overview ende 6 Assembly The components Jecuseschsnaaseienehhennsrieichnaksolenierleunese 1 Assembly zc ete EE MER REESE E esit nn due oer eg re ae 8 Use Switching on and Off iss casarse sosse cece eee ee 9 Acoustic signal 00 c cece sem n 9 nn ge 9 FOotswitch u ae u 9 acude UE 10 The focusing position Storing travelling cancelling 222222 10 Focusing with the PC liiiissssssssssssssssse I 10 Description Purpose The purpose of the motor focus system is to provide motor driven coarse and fine focusing by means of a manual control a footswitch or through a computer Five exact focus settings can be stored so that the instrument can travel to them directly The motor focus system offers the following advantages over manual focusing e Easy to use even with heavy outfits e Ergonomically better More flexibility for the user Leaves the hands free e Saves time during repetitive tasks For Leica stereomicroscopes The modular design of the motor focus system enables it to be fitted to the incident and transmitted light stands and large swinging arm stand of the LEICA MS5 MZ6 MZ8 MZ12 MZAPO and MZ FLIII stereomicroscopes and of the LEICA M420 macroscope
2. User manual The present user manual describes the design and use of the motor focus system There is a separate user manual for the stereomicroscope or macroscope For safety directions and for detailed information about the stereomicroscope or macroscope and how to clean it and about its stands illuminators and accessories please refer to the user manual for that instrument Safety concept Before you try to set up and use the motor focus system read e this user manual and in particular the safety notes e the user manual for your stereomicroscope or macroscope including the notes about safety and care Permitted uses The motor focus system is intended for the motor driven raising and lowering of the LEICA MS5 MZ6 MZ8 MZ12 MZAPO and MZ FLIII stereomicroscopes and of the LEICA M420 macroscope on Leica incident and transmitted light stands and on the large swinging arm stand and it replaces the mechanical drive housing The motor focus system consists of acolumn with motor focus mechanism atransformer with a power cable e amanual control and or a footswitch and or a PC interface kit Prohibited uses The use of the motor focus system in a different manner from that described in this user manual can lead to injury malfunction and damage e Do not fit different plugs e Do not attempt to modify the motor focus system e Do not dismantle any part of the motor focus system unless instructions for doing s
3. clinable carrier rod to the horizontal arm in accordance with the user manual for the stereomicroscope or macroscope Using the clamping screw secure the lower stop to the carrier rod see page 9 Microscope carrier gt column with motor focus mechanism Using an Allen screw secure the microscope carrier to the column of the stand refer to user manual for stereomicroscope or macroscope Fitthe optics carrier binocular tube and accessories to the stereomicroscope or macroscope in accordance with the user manual Transformer Respect the directions for safety on pages 4 and 5 Technical data Type MST31 Input voltage 85 to 264 VAC Input frequency 47 to 440 Hz max 0 80 A at 115 VAC max 0 50 A at 230 VAC Operating voltage 30V Operating temperature 10 C to 40 C Storage temperature 20 C to 55 C Maximum mechanical loading 12 kg Input current Connecting the motor focus Co N v www Connector for transformer Connector for footswitch or for PC interface kit Connector for manual control Connect the transformer to the motor focus mechanism Connect the power cable to the electricity supply Connect the manual control and or footswitch If appropriate connect the PC interface kit instead of the footswitch Us e Safety measures for the stops Read the warnings on page 5 The fixed stop 5 on the upper part of the column and the adjustable stop 6 beneath the motor housing limit
4. hen focusing keep your fingers away from e the space between the motor housing and the lower stop e the space between the objective and the object the surface of the stand the stage insert and the stage Precautions by the manufacturer The lower stop must be adjusted individually in accordance with the characteristics of the object see below Safety note Always setthe lower stop correctly in relation to the object see page 9 If itis set too low e the user s hands might get crushed between the objective and the object e the object might get flattened or otherwise damaged e the objective might get damaged Power cable e Inspect the power cable regularly for damage If it is defective replace it immediately because it can cause the instrument and ancillary equipment to become electrically live endangering personnel Do not pull at the power cable e Position the power cable carefully and make sure that no one can become entangled in it or fall over it Cleaning e Disconnect the power cable before you attempt to clean the motor focus system e Respect the warning signs relating to the handling of liquids e Read and follow the notes about cleaning which are given in the user manual for the instrument Liquids Be careful when handling liquids If spilt on electrical appliances they can e cause the instruments and accessories to become electrically live endangering personnel cause damage to the equi
5. o are given in the user manual e Do not allow the motor focus system to be opened by unauthorized personnel Place of use The motor focus system is intended for use only in closed rooms Responsibilities of person in charge of instrument e Ensure that the motor focus system is operated maintained and repaired only by authorized and trained personnel e Ensure that personnel who use the motor focus system have read and understood this user manual and in particular all safety instructions Safety regulations Repairs and servicing e Only Leica trained service technicians or technical specialists assigned by the person in charge of the instrument are permitted to carry out repairs e Only original Leica spare parts may be used e Disconnectthe power cable before opening the transformer otherwise there is a risk of injury through electric shock Precautions by the manufacturer e The motor focus system is electromagnetically compatible in accordance with the directive 89 336 EEC and can be operated at the same time as other electrical appliances e Low voltage protection prevents electric shock if the circuit inside the motor housing is touched e Stops on the column and end switches on the motor housing limit the upward and downward movement of the motor focus system The end switches prevent it from attempting to travel further when it encounters the stops AN Warning Danger of crushing and other injuries W
6. orage is confirmed by two short beeps Focus on the second point in the object and store inthe same way Focus and store up to five points in the object Travel to the stored focus positions gt Briefly press the black switch 12 To cancel the focus positions gt Keep the black switch 12 pressed until you hear two short beeps a pause and two long beeps Focusing with the PC e In addition to a standard PC with RS232 interface you need a PC interface kit from Leica e The individual functions and commands are described in a separate user manual for the PC interface kit
7. pment Legal requirements Adhere to general and local regulations relating to accident prevention and environmental protection Conformity with European Community directive The motor focus system and its accessories are constructed in accordance with the latest technologies and are provided with a statement of conformity with EC requirements Overview Components Motor focus system on incident or transmitted light stand Stereomicroscope Stand with column and motor focus system Transformer Handswitch Footswitch Standard PC not illustrated 0o a c9 N Motor focus system on large swinging arm stand 7 inclinable carrier rod with motor focus Assembly The components 1a 300mm long column with motor focus mechanism 1b Inclinable carrier rod with motor focus 2a Incident or transmitted light stand 2b Large swinging arm stand 3 Lower stop oo Cc Cc A Microscope carrier Optics carrier Transformer not illustrated Handswitch Footswitch PC interface kit not illustrated Assembly Incident or transmitted light stand Column with motor focus mechanism gt base of stand Using three Allen screws secure the column to the incident or transmitted light base refer to user manual for stereomicroscope or macroscope Using the clamping screw secure the lower stop to the column taking the position of the object into account see page 9 Large swinging arm stand Fit the in
8. the movement of the motor focus system e In addition there is an end switch 7 on top of the motor housing and another one beneath it If during focusing an end switch touches the stop there is a series of beeps and the movement ceases Set the lower stop e so that your hands have enough room between the objective and the object even when the motor focus system has reached the stop e so that during focusing the objective cannot press against the object and damage either objective or object gt Place the object beneath the objective gt Look into the eyepiece and carefully bring the object into focus using the manual control see page 10 the footswitch or the PC see page 10 gt Use the clamping screw 8 to secure the lower stop beneath the motor housing Focusing Footswitch Switching on and off gt Switch on the motor focus system switch 4 e Confirmation by acoustic signal Acoustic signal There is an acoustic signal when the system is switched on one short beep there is a changeover between coarse and fine focusing one short beep e the focus position is stored two short beeps e the focus position is cancelled two short beeps pause two long beeps the stop is reached series of beeps To switch off the acoustic signal gt When switching on the system press switch 11 or 12 on the trol 10 tivat itch manuabepntrelses page TO AF CUIR UG Tanne e To foc
9. us using the footswitch Left hand switch 15 up right hand switch 16 down e To change between fast and fine focusing Press left hand and right hand switches at the same time e Focus positions cannot be stored by means of the footswitch Handswitch 10 11 12 Rotary knob for focusing Red switch for alternating between coarse and fine focusing Black switch for storing or cancelling up to five focus positions and for travelling to the stored positions Focusing with manual control Respect the safety notes on pages 4 and 5 Focus with the red rotary knob 10 Anticlockwise down clockwise up Change between coarse rapid focusing and fine focusing by briefly pressing the red switch 11 When the system is first switched on the rapid focusing mode is active Storing the focus position Focus positions can be stored only by means of the manual control or the PC Amaximum of five focus positions can be stored If a sixth focus position is stored the one nearest to it will be cancelled Each focus position can be cancelled individually The system will travel to each of the individual focus positions in the sequence in which they were stored Switching off the system cancels all of the stored focus positions Place the object beneath the objective Setthe lower stop see page 9 Focus on the first point in the object Press the black switch 12 for at least 1 5 seconds The st