Home

LCD Console Tray CFP185KMM8 & CFP185KMM16

image

Contents

1. Scroll Lock Caps Lock This option can set the scan time The default timer is 3 seconds The Timer Setting alternative option 3 SEC 8 SEC 15 SECT 30 SEC 188 Other functional operation Hot swap The CFP185KMM8 16 supports hot plugging which means that components can be removed and added back into the installation by unplugging their cables from the PC connection Ports without the need to shut the unit down There are certain procedures that must be followed in order for hot plugging to work properly x Note Some O S Operation Systems like SCO Unix are unable to support Hot Plug function If you apply Hot Plug to this kind of O S it will cause unpredictable behavior or shut down the PC Before attempting to use Hot Plug please make sure your O S and software driver supports the Hot Plug function If it happen unusually the mouse will stop working In order to make sure the system down will not occur for the unusual state you should plug down the signal cable of CFP185KMM8 16 and insert back the CFP185KMM8 16 after 10 second the system will become normal Shutdown e Press the LCD POWER shut down the LCD power LED is off e Close down the front panel e Push Front panel module in properly the power is off automatically 14 Troubleshooting 1 Make sure all of the cable is connected the CFP185KMMg8 16 signal cable is not be connect
2. LCD Console Tray CFP185KMM8 amp CFP185KMM16 User Manual EMERSON Network Power Attention nnannannennennnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnna nran nr naonna nnn ana aranana onenen 2 EE TEE e tonite A N 3 General OescriptiON occccconccnccocencconncncnonnnnnoncnnnnnonrncnnnnnncnnannnnnnnos 3 EG ee 3 ENN 4 A EE eg PP A lt A 6 Rack MOuUNUNg GP 6 Connecting equipment o occcccnccnconcnnccncnncnncnncnnnncnncnnonnrnnonarnnnnannnss 7 Daisy Chain Connection eranneernurenvnnrenvnnernvansennursennnvennnunennnnr 8 AAA N TE EEEE 9 0 SN 9 Monitor OSD menu rnrerrannnsrnnrnnnnsnnrnnnssennannnsnnnnnnnnsnnnnnnssenn 10 Switch OSD menu rrrrrnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnn 11 Other functional operation cccoocccconcnccnncnnoncnnconcnncnaraconannnononos 13 TEQUES NOO ao PEN 14 SPecIifICatiONS oooococcconococancconoooncnononononnnnnnnnnononnnnnnnnnonnnnnnnnnnnnnnns 15 oe dd 1 please read this user manual before you use it 2 be care for attribute of power 3 you must pull out the display part of this set before you use It 4 the power will auto turn on or turn off when you pull it out or push it in 5 The panel can be open to 110 for using 6 Please make sure that the OS of your computer support hot plugging or not and read the part about hot plugging of user manual 7 We suggest that you should set the resolution of monitor at 1366 768 60Hz Ove
3. T Main menu operation instructions Function Operation o Function description name method Auto scan mode This function allows you to automatically switch among the available computers Autoscan F1 at regular intervals so that you can monitor their activity without having to take the trouble of switching yourself E AS a Modify the port name The maximum number of characters allowed for the port name is 8 Legal Chg Name characters include A Z 0 9 Case does not matter the OSD displays the port name in lowercase no matter how they were keyed in Under the OSD main menu click the Ctrl button the pop up secondary menu setup Menu t MOVE ESC QUIT Function description This option can find the port In the search for Port Name edit field enter the part or all of the name you want to find after press the Enter Port Search key The system automatically filters qualifying ports and displayed in the bottom window Select the port and press the Enter key to switch the port This option can set or change password for a user Note only the User Security 7 administrator can perform this function This option can set user access rights This screen displays the port Access List corresponding to each user access V stands for enable x stands for disable Administrators have the highest access g This option can be set hotkey The default hotkey is Lock Caps The ll alternative hotkey Ctrl
4. center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands Our solutions are supported globally by local Emerson Network Power service technicians Learn more about Emerson Network Power products and services at www EmersonNetworkPower Asia Stay connected in JE JE Emerson Network Power Asia Australia T 1800 065345 F 61 2 97810252 Indonesia T 62 21 2513003 F 62 21 2510622 Japan T 81 3 54038564 F 81 3 54032919 Korea T 82 2 34831500 F 82 2 5927886 Malaysia T 603 78845000 F 603 78845188 New Zealand T 64 3 3392060 F 64 3 3392063 Pakistan T 92 42 36622526 to 28 F 92 42 36622530 Philippines T 63 2 7207400 F 63 2 6203693 Singapore T 65 64672211 F 65 64670130 Thailand T 66 2 6178260 F 66 2 6178277 to 78 Vietnam T 84 4 37628908 F 84 4 37628909 Marketing ap emerson com www EmersonNetworkPower Asia While every precaution has been taken to ensure accuracy and completeness herein Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Specifications are subject to change without notice Emerson Network Power and Liebert are trademarks of Emerson Electric Co or one of its affiliated companies All other names and logos referred to are trade names trademar
5. ed wrong Please bundle the cable of PC and mark it 2 We suggest that the VGA cable is not more than 5 m 31 Don t press the key board when the system is starting because the system may do not find the keyboard 4 When you use the Cable USB please set your PC BIOS to enable USB function if PC can t work properly We suggest that the VGA cable is not more than 5 m 5 Computer start normal but the keyboard is not working Make sure other keyboard can be working if it connect to this computer Check the signal cable is connected or not 6 Computer can not detect the mouse Make sure other mouse can be working if it connect to this computer Avoid press the key of mouse or pull out the signal cable when you switch channel Avoid shut down the computer when you switch channel 7 Because the monitor need 1 2 second for display different models so that the scan time should set more than 5 seconds 8 When windows OS show the following information Windows did not detect a mouse attached to the computer you can safely attach a serial mouse To attach a mouse to PS 2 mouse port you must first turn off the computer Please tick Do not show this message in the future To finish Booting Windows O S 91 When the SUN servers is starting which the edition of OPEN BOOT below 5 0 don t operate the function key like STOP A before it finish the booting device 10 If forgetting the password you typed please co
6. enu Blue normal Purple Red Blue power saving mode or Indicator Status disconnection of signal cable Please press the AUTO key if the screen s excursion occurs during starting the machine switching to other channels or at other cases then the screen will be adjusted automatically to reach the best display status We suggest the clients set the display mode at 1366x768 60Hz e Switch OSD menu Enter the system Press twice of Lock Caps within 4 seconds into Hot Key Command state You will hear a beep for confirmation and the keyboard is in hot key mode If you have not pressed any key in hot key mode within 4 seconds the keyboard will back to under Operation System control state Function Operation a Function description name method Port Switch the last Port Switching Switch the next Port OSD main Space OSD main menu eject operation See OSD menu bar menu operation Restore F9 F11 factory Sequence settings press The OSD menu can be reset to the product originals by Administrator e OSD menu operation The Lock Caps key must be pressed twice and then the Spacebar must be pressed within 4 seconds You will see the OSD menu Main Menu Current selection port Port 01 Cascade layer state DANK 1 CUR admin A Curent user ID PORTNAME SYSTEMOO Fi AUTOSCAN 02 SYSTEMOO F2 CHGNAME SYSTEMOO CTRL MORE SYSTEMOO PGDW BANK SYSTEMOO PGUP BANK SYSTEMOO SYSTEMOO ESC QUI
7. ks or registered trademarks of their respective owners 2015 Emerson Electric Co AP15ENT CFP185KMM8and16_V1 UM EMERSON CONSIDER IT SOLVED
8. n bank is sixteen levels CFP185KMM8 Cascaded first layer o Gwe Ce Ro LE BE PO Bo Gi Ba Be BD ait Signal line gt Cascaded line i PC Or SERVER gt ip ul Daisy chain In gt 09 a E O E ED E KD KRD De KD Ge Daisy chain Out Cascade second layer Console Port CONSOLE GB E el Je IN Same series of switch ar gre ee ge KK VEKE Cascade third layer O O 0 0 0 0 0 0 O O Same series of switch Cascade sixteenth layer Make sure that all devices on the installation are properly grounded Make sure that the KVM cable and power cord should be connected correctly Then you can use it Begin to use e Press the unlock switch e pull KVM Drawer panel module out and the slide rail is locked automatically Power is on e Release the front panel locker PRESS UNLOCK Cs e This can open the display part be open to 110 degree Xx Note the open angle can not be more than 110 otherwise it may damage the equipment Pm 110 Press the LCD Power button when the LED indicator is on 10 Monitor OSD menu Adjust of Display function depend on LCD OSD Key Specific control key functions such as table Control key name Function description LCD POWER Turn on and off the monitor power MENU Calls OSD menu AUTO auto adjust SL SL Moves the selector left and right on the OSD m
9. ntact your supplier Specifications 15 project name PRE GEPIBSKMMIG Project Name Number of computer connections KVM switching function Connect port selection Cascade port Cascade layer Recommended resolution Visual area Display function ae Backlight LCD adjustment LCD on off Keyboard keys Mouse button Keyboard and mouse Compatibility The built in power supply AC power input module Two choose one DC power input Power Recommended working Working environment Storage temperature Humidity Shell Machine net weight Physical features Equipment size length x width x high CFP185KMM8 CFP185KMM16 Specification parameter 8 16 OSD menu selection hotkey 256 16 1366 x 768 DDC2B 18 5 Inch LED 4 x Button 1 x Button 100 Key 83 Key keyboard 17 Key independent digital keyboard 2 x Button Support Windows Microsoft system support MAC system support LINUX UNIX NETWARE system 90V 264V AC 36V 72V DC 20W 0 50 G 20 60 C 0 80 RH No condensation Metal Plastic 10kg 594 5mm x 481mm x 42 5mm About Emerson Network Power Emerson Network Power a business of Emerson NYSE EMR delivers software hardware and services that maximize availability capacity and efficiency for data centers healthcare and industrial facilities A trusted industry leader in smart infrastructure technologies Emerson Network Power provides innovative data
10. rview General description CFP185KMM8 16 is a console that integrates the KVM Switch function of multiple ports in 1U It can manage multiple computers through a single set of console LCD monitor keyboard and mouse There is no better way to save space and money than with a CFP185KMMg8 16 One CFP185KMM8 16 can be directly connected and controlled 8 16 hosts matched by cascading switches to control up to 256 PC Setup is fast and easy plugging cables into their appropriate ports is all that is entailed There is no software to configure so there is no need to get involved in complex installation or incompatibility problems CFP185KMM8 16 works on any hardware platform and with all operating systems Features e Integrated LCD display keyboard mouse and switch e 18 5 inches LED energy saving display e Scissors foot type ultra thin notebook keyboard e The machine adopts the towline type protective design and signal cable design to avoid loss caused by the repeated pumping e High quality dedicated slide rail e Overall 1U height suitable for standard cabinet installation e Do not need to install the software and allow to operate directly the computer e The number of computer controllor can be expanded to 256 units e Built in 90 264V AC power supply Optional 48V Telecom stage DC power supply Provide safety protection of telecommunication level e Automatic power protection design When not using the device which is to promo
11. te the cabinet automatically enter protected mode e Meet DDC DDC2 DDC2B standards comply with VESA standards Appearance Front view 1 LCD display 2 Keyboard 3 Mouse 4 Slide rail lock 5 LCD OSD key board Rear view o mm CB Ce ES ES Eo Eo Ee EJ EJ EJ EJ EJ Eo Eo e l 2 3 4 5 No Description 1 Earthing point 2 External display port 3 Cascade port 4 PC connection port 5 Power input port Structure size Installation Rack Mounting Installation requirements CFP185KMM8 16 conforms to the standard 19 cabinet suitable for cabinet installation depth 600mm 850mm Connecting equipment CFP185KMM8 16 signal line and it s use of connection ENE EH EN EN UN UH UH UH ED A OONAN OON piian I PUT TE ETT ETT PETTITTE TUTTE CFP185KMM8 16 power cord and it s use of connection Wide voltage range Applicable models AC power cable 96 264VAC 47 63Hz AC power input e z 220V AC pover cabl e Daisy chain connection If need connecting more Exceed 8 and 16 PC or Servers you can through chained Switch in order to control it u Please use the attached 3 in one daisy chain Cable Kit to daisy chain the Switch u Use one end of Cable Kit to connect the daisy chain port of CFP185KMM8 16 and the other end for the console port of bank switch u Please repeat item B to daisy chain more bank as you want But the maximum daisy chai