1. ODONICS 3 Infinity Web Viewer Microsoft Internet Explorer Ein Ki Yew fpo ook p ir o Bach aw a f 7 Search vr Favorites E c Lus 3 8 eto d fvted Ir esty eben Man sepa Go ms User Codanics 0 Infinity Web Viewer Vv Caroud Kathy 34097 Carote 11 9 2005 MP 1 12 gt Ej toe trated om len Infinity Web Viewer Reference Guide Table of Contents OVER 1 Security Considerations Sanidad iaa 1 System SD ci 1 Infinity Configuration ni lia 1 Workstation Prerequisites ccccsssssecsseseessesseeeeenseeeeenseeeneeseeesenseesoenseesoeneessonas 2 Contig ring Internet Security den 3 RUNNING the WeD VIeWOLF aiite deoa nee 4 Accessing the Application from a Client Computer 4 Searching for Patients and Studies eeeececereseeeeeeeuu 5 Viewing Information on the Study Tab eee ecc ceeeeeeeunu 7 Viewing Images on the Series Tab ec ceeeeeeeee eer creeeeen enne 8 Viewing Images in the Advanced DICOM Viewer 10 Managing User Preferences on the Settings Tab 12 Troublesho0llNnd e 13 CODONICS Overview The Codonics Infinity Web Viewer is a standalone application used for viewing patient study and series information as well as digital m
2. changing user password 4 Click the Login button You are logged in to a Web Viewer session Searching for Patients and Studies Once logged in the Web Viewer displays the Browser tab which you can use to enter patient and study search criteria User Codonics N CODONICS Infinity Web Viewer Browser MEENU Patient Name Patient ID Birth date 7 To 3 gt Study Description Study ID Sex xj Acccession Number From 2 To Fe gt Modality Body Part Series Description B Ei Search Clear Hide Reset Custom v Save Search criteria entered in text fields such as Patient Name will search for matching studies based on the beginning text For example entering the letter C in the Patient Name field will search for patients whose last name begins with C as in the example below Cardio Carotid Chest Circulation Coronary Entering SM will find all patients whose name begins with SM for example Smith Smythe Search criteria are not case sensitive for patient name but are case sensitive for Patient ID and Study Description After entering the search criteria click the Search button to execute the search User Codonics CODONICS Infinity Web Viewer Browser BESCO Patient Name Patient ID Birth date M To Study Description Study ID Acccession Number Study Date From rs To Fr gt Modality Body Part Series Description v v Clear Hide Res
3. name from the workstation All registered and unregistered trademarks are the property of their respective owners Specifications subject to change without notice Copyright 2009 by Codonics Inc Printed in U S A Part Number 900 460 001 09 13
4. se a User admin CODONICS Infinity Web Viewer Browser Study series Settings x Infarct Igor 3453456 Large Pathology Infarct 4 5 2005 FLAIR COR S MR 5 40 lt gt To select a thumbnail for larger image display click on the desired thumbnail image To page through the thumbnails click the arrows above and below the thumbnail strip 0 Infinity Web Viewer Reference Guide To change the sizing of the large image display click on the image Choose the desired sizing option from the selection list Za CODONICS Infinity Web Viewer Browser Study series Settings Coronary Collin ID731 CTA Coronary Arteries 3 28 Demo cr 1 26 t view real size Fit am Fit width Description Displays the image in its fullest JPEG size and resolution non DICOM If the image does not fit completely in its display area use the scrollbars to pan and scroll the image ES Fits the image to the size of the browser window Maximizing the browser window and using higher resolution monitors can allow larger image presentation IP 4 Fits the image width to the display area width This is often in between the fit to window and full size settings CODONICS 9 Viewing Images in the Advanced DICOM Viewer Advanced viewing is an option you may have purchased Advanced viewing is launched by clicking the Magnifying Glass icon on the Browser Study or Series tabs TIP Advanced viewing c
5. the SeHings Tab User preferences can be set on the Settings tab Any changes to these settings are stored for the current user and are used in all future sessions User Cully 0 N CODONICS Infinity Web Viewer Browser Study Series Ml settinos Study raw clicking Browser Series row clicking Dicom v Modalities Body Parts Change password Refer to the following table for a description of the preference settings Description Study row clicking and Optional Specifies whether to open images in the Web Viewer Series row clicking browser window or the Advanced viewer when clicking a row in the Study or Series tab Layouts Controls the layouts on the Series tab A single layout is provided for all modalities and can be modified Additional layouts can also be created for specific modalities CR CT MR etc Layouts Modality lm Thumbnails 1x1 Ta Jur Click the Tr icon to edit an existing layout or create a new one Click the x icon to delete the corresponding layout Modalities and Body Modalities and Body Parts can be selected or deselected for Parts inclusion in the search screen s drop down selections for these attributes Change Password Change your login password 12 Infinity Web Viewer Reference Guide Troubleshooting Problem JPEG images are not displayed in the Basic viewer The Advanced viewer does not download or launch Advanced viewer does not display DICOM
6. virtinF Require server verification https For all sites in this zone Close 7 Make sure the Require Server Verification option is unchecked 8 Enter the Infinity URL address for example http 10 1 90 24 or http InfNetName NOTE The IP address or network name can be obtained from your network administrator 9 Click the Add button 10 Click the Close button to close the Trusted Sites dialog box and go back to the Security tab 11 Set the Allowed Levels to Low or Medium Low 12 Click the OK button to save the security settings NOTE After setting the security settings it is recommended that you exit and restart Internet Explorer Running the Web Viewer Accessing the Application from a Client Computer 1 Navigate your web browser to http lt Infinity_IP gt 2 Click the Web Viewer link The Web Viewer application login prompt displays Infinity Web Viewer User Password Hot intended for primary diagnostic application TIP The web viewer can also be accessed directly by navigating to http lt Infinity IP gt WebViewer TIP This page can be bookmarked or added to you favorites for easy access in the future 3 Enter your user name and password Both entries are case sensitive The default user name is operator and the default password is codonics all lower case 4 Infinity Web Viewer Reference Guide TIP See Managing User Preferences on the Settings Tab for
7. an also be set as the default viewer from the Browser or Study tab based on your user preference settings Please see the section on Managing User Preferences for more information Viewing an entire study Selecting Advanced viewing from the Browser tab will download all images in the study to the Advanced viewer Viewing a specific series Selecting Advanced viewing from the Study or Series tab will initially download only the images in the selected series Once the Advanced viewer has launched information on all series is available from the Browse icon on the Advanced viewer menu bar Selecting a series from this menu will download the series images from the Infinity server if the images are not already downloaded NOTE DICOM images are significantly larger than images shown in the Web Viewer Slow network connections may result in significant delays before images are shown TIP Selecting a specific series from the Study or Series tab for Advanced viewing will avoid downloading an entire study and can reduce the time required for Advanced viewing After selecting Advanced viewing the following message will appear while the application prepares the Advanced viewer Launching Application p v verifying application requirements This may take a Few moments NOTE If the Advanced viewer has not been previously downloaded or a new version is available the application is automatically downloaded If the dialog box shown below
8. are displayed 6 Infinity Web Viewer Reference Guide Viewing Information on the Study Tab Note All images presented in the Study and Series tabs are lossy JPEGs and are not intended for primary diagnostic application To display patient study and series information on the Study tab click the folder icon a or anywhere on the line other than the Magnifying Glass icon the Browser tab An example Study tab is shown below This view shows patient and study information and a list of series in the study with a small thumbnail image for each series for reference User manager O N CODONICS Infinity Web Viewer Browser study Series Settings e Infarct Igor Birth date 1 27 1938 OEA 4 5 2005 16 44 54 Study ID 165948291 Large Pathology Infarct Modality Description Body Part 04 05 2005 16 58 05 04 05 2005 17 03 50 08 31 2005 10 47 53 Viewing Images on the Series Tab To display images in the Series tab click the folder icon LY or anywhere on the line other than the Magnifying Glass icon CR from the Study tab The Series tab displays a list of thumbnails along the left side of the view These images are numbered in the lower right corner The center portion of the screen Will display a larger image of the selected thumbnail TIP The large view can be configured to display more than one image Please refer to the section on Managing User Preferences for more information N
9. edical images from Infinity Medical Image Servers Security Considerations The Infinity Web Viewer is intended for use on private and trusted networks Any access to the application outside of a private trusted network such as access from the Internet should be protected by authentication and encryption at the network layer such as through a virtual private network VPN DICOM and JPEG image data is temporarily stored locally on end user workstations when viewing is performed Precautions for protecting workstations that conduct viewing should be implemented and enforced System Setup Infinity Configuration NOTE Placing the Infinity directly on the Internet is not a recommended practice due to security and privacy concerns Access from public networks should be secured with encryption and authentication measures such as a VPN Direct access to Infinity from the Internet will require the setup of a domain name and router and firewall configuration expertise To enable JPEG images a configuration is required for all DICOM stations that send studies to Infinity 1 Open the Infinity Administration tool from the Infinity desktop 2 Select an existing DICOM station or create a new DICOM station 3 Select the Import tab in the DICOM Station s properties CODONICS Select When association is closed or After a timeout a typical timeout is 30 seconds in the Study completed field Dit Sraion s properties Ed NOTE If st
10. et Custom Save Patient Name 4 Patient ID Birth date Description Date Study ID e C Cardio Klaus 12345 1 1 1947 Intervential Cardiac 06 30 2004 08 24 239542 Heart e g Carotid Kathy 34897 12 29 1941 Carotid 11 09 2005 12 27 184768055 Carotid g C Chest Charley F318977 4 21 1952 Chest X Ray PA amp Lateral 10 23 2006 00 00 CHEST e Cu Circulation Caesar 895723 6 12 1951 Cardiac Circulation 06 12 2006 18 14 789432 HEART e a Coronary Collin ID731 8 28 1953 CTA Coronary Arteries 03 29 2005 14 25 4415342 Other search criteria functions are described in the following table Clear any entered search criteria but Click the Clear button not re execute the search Hide the search criteria Click the Hide button Redisplay the search criteria if it is Click the Show button hidden Save common searches for re running Click the Save button at a later time Run a saved search Select the search from the Custom list After clicking the Search button matching studies are displayed in a results list To sort the result list click on the desired column heading Click the heading again to toggle between ascending and descending order indicated by the arrow direction next to column name Note If more than the 25 studies match the criteria a message indicates that not all studies will be displayed Click OK but be aware that only a partial list of matching studies is displayed Microsoft Internet Explorer A Too many items Mot all results
11. images CODONICS Infinity DICOM stations must have Study completed configuration set to When association is closed or After a timeout Refer to the section on Infinity configuration The net 3 5 SP1 framework is not installed Refer to the section on Workstation prerequisites The net framework may not be operating correctly Delete all instances of the net framework using Control panel Add remove programs and reinstall the net 3 5 SP1 framework Make sure the workstation or PC client has the color set to 24 bit true color or greater The Infinity server is not added to the workstation s Trusted sites or the Trusted sites security setting is not set to Medium low Refer to the section on Configuring Internet security Network ports 23666 236667 and 23668 must be open for DICOM images to download If a firewall is used on the workstation ensure these ports have been added as an exception If a firewall exists on the network ask your network administrator to allow activity on these ports The net framework may not be operating correctly Delete all instances of the net framework using Control panel Add remove programs and reinstall the net 3 5 SP1 framework The Infinity s hostname must resolve to the Infinity IP address Contact your network administrator for assistance in ensuring that internal DNS tables are properly configured As a simple test the Infinity should respond to a ping of the Infinity s machine
12. is displayed click the Run button to download the Advanced viewer application Application Run Security Warning Publisher cannot be verified Are you sure you want to run this application Mame Infinity Viewer From virtinf Publisher Unknown Publisher Run While applications From the Internet can be useful they can potentially harm your computer If you do not trust the source do not run this software More Information 10 Infinity Web Viewer Reference Guide Once the Advanced viewer is loaded the following message will display while the viewer launches and begins to download images Starting DICOM viewer please walt Codonics Infinity Viewer The Advanced viewer will display once initial images are available for viewing File Edit View Tools Window Help a t xo e oF FE CIE Ang je E A O OHER ar I Er I Coronary Collin T 51 years M ID731 Sie taal Acc ACC731 3 29 2005 Demo 968x968 Mag 0 90x Spin 68 Tilt 44 72cm CT54023 64 Slice CT General Hospital Oo User admin Mem used 90 7M free 61 NUM NOTE Images may still be downloading after the Advanced viewer is displayed NOTE For further information on using the Infinity Web Viewer refer to the Clarity User Manual Codonics Part No CLARITY MNLU Not every feature shown in the Clarity User Manual is available on the Infinity Web Viewer 11 O CODONICS Managing User Preferences on
13. udies existed on the Infinity prior to enabling the Web Viewer or studies were stored to the Infinity and the Study completed field was not properly configured JPEG images will be missing from these studies Contact Codonics Technical Support to generate JPEG images for web viewing of these studies Workstation Prerequisites The following prerequisites must be met on any workstation running the Infinity Web Viewer NOTE Installing required components and security settings may require access levels available only to a system administrator If you experience any difficulty installing or configuring these prerequisites please contact your network administrator for assistance Microsoft Windows XP Microsoft Internet Explorer version 6 or 7 Microsoft NET Framework version 3 5 SP1 or greater is required for Advanced viewing To verify NET framework installation and version open the Add or Remove Programs tool in the Windows Control Panel and review the list of installed applications for Microsoft NET Framework 3 5 SP1 or greater If not installed this component can be downloaded and installed from http www microsoft com downloads On this page open the Product Families menu and select Developer Tools A workstation or PC client must have a minimum of 2 GB RAM to properly display studies A workstation or PC client must have the color set to 24 bit true color or greater Internet security settings must be properly config
14. ured Refer to the next topic Infinity Web Viewer Reference Guide Configuring Internet Security 1 From Control Panel or Internet Explorer Tools menu select Internet Options The Internet Options dialog box displays Go to the Security tab Internet Options Select a zone to view or change security settings zh L E ee Y O Internet Local intranet ici ls Restricted sites Trusted sites This zone contains websites that you trust mot to damage your computer ar our Files You have websites in this zone Security level Far this zone Allowed levels For this zone All Low Minimal safeguards and warning prompts are provided Most content is downloaded and run without prompts All active cantent can run Appropriate For sites that vou absolutely trust Custom level Default level Reset all zones to default level The settings must be updated to add the Infinity server as a trusted site The Trusted Sites zone must be set to a medium low or low security level Click the Trusted sites settings icon from the zone selection box Click the Sites button The Trusted Sites dialog box displays Trusted sites You can add and remove websites From this zone All websites in this zone will use the zone s security settings Add this website to the zone Web sites http i Fsweb nd codonics com http ffsql4 ni codonics com http fi