Home
USER MANUAL
Contents
1. N a veracity USER MANUAL How TO USE TIMENET TIMENET is used to provide an accurate atomic clock reference time to network devices using Network Time Protocol NTP TIMENET receives the reference time directly from the GPS satellite system and so is a top level i e Stratum 1 system clock and provides a legally verifiable time with full traceability TIMENET allows CCTV systems especially DVRs and Access Control Systems to be properly synchronised to the precisely correct time without using an external Internet connection Windows PC Linux Server TIMENET NTP Master In the example shown a TIMENET unit is used to synchronise three DVRs an Access Control system and both Linux amp Windows PCs CABLE CONNECTION DIAGRAM Reset socket Network cable 12V DC Power INSTALLATION SEQUENCE 1 MOUNTING A The TIMENET unit should only be installed indoors or in an appropriately rated enclosure The GPS antenna should be mounted on the inside of a window which has at least a partial view of the sky although the greater the view of the sky the faster the GPS lock see separate antenna mounting instructions If the TIMENET unit is to be located on a wall then the supplied wall mounting tabs should be slid into the slots on the side of the case Note if these are not fitted already the network end plate should be unscrewed and the black plastic collar removed first before sliding in the wall
2. MENET on the your local network if you are unsure of the IP address Click on Connect This will connect to the TIMENET device If the program cannot see the TIMENET check your network connection and settings using the PING command The TIMENET program will show Connect Network Scan q the dialogue as Damea Lead 4 shown left The veracicy UTC time will be Status shown as well as the local time as defined by the local setting of the Windows time zone To change the IP address setting for Change IP address your application simply enter the IP address Subnet mask and Gateway Click on Apply to write the settings to TIMENET This will automatically cause the TIMENET system to re boot with the new IP settings This will take a couple of minutes Be sure to re set the PC to the new IP domain before re checking TIMENET operation Note that the Time Sync LED on the dialogue above make take some time to turn from Red to Green as this is a function of the NTP system which requires good signal lock for a period before properly synchronising with the atomic time reference KA TIMENET Configuration 16 39 42 19 August 2008 17 39 42 19 August 2008 GPS lock oO Time sync Version 1 2 0 IP address 255 255 255 0 Subnet mask Gateway To reset TIMENET to its default IP address use a paper clip to press the reset button see connection diagram TIMENET will re boot with the default IP address Note th
3. at you can synchronise your Windows PC to TIMENET using the Internet Time tab of the Windows clock set up dialogue Enter the TIMENET IP address in the server field Click on Update Now and check to see that the system synchronises properly TIMENET is now acting as an accurate NTP server for your Windows PC SOFTWARE amp COPYRIGHT NOTICES This manual and the Veracity TIMENET Config application are Veracity 2007 amp 2008 TIMENET contains open source products released under GPL V2 NTP license The relevant products can be downloaded for free from the following locations or be provided by Veracity UK Ltd for a fee upon request to info veracityuk com uClinux http www uclinux org NTP Server http www ntp org BusyBox http www busybox net Windows is a Microsoft Trademark MANUFACTURER S DECLARATION OF CONFORMITY The manufacturer declares that the equipment enclosed with this certificate conforms with the essential protection requirements of the EMC Directive 89 336 EEC and has been designed and manufactured to the following specifications BS EN 55022 1998 Emissions Radiated BS EN 55024 1998 Immunity BS EN 61000 4 2 1995 Immunity to ESD BS EN 61000 4 3 20002 Immunity to Radiated RF Fields 3V m RoHS FE CE TIMENET Manual version 1 3
4. mount tabs and re assembling The unit should be securely mounted and should not be supported by the attached cables Connect the GPS antenna cable ensuring that the cable connector is screwed on 2 NETWORK amp POWER CONNECTION A TIMENET should only be used with a Class Il Isolated power supply Connect the network cable and the 12V DC power also compatible with 10V 40V DC and 24V AC The green LED will switch on immediately to indicate power During boot up the LED will go off on then off again After a minute or so the green LED will blink with short pulses This indicates normal running with no GPS signal lock After a few minutes assuming the GPS antenna has been properly mounted and connected the green LED will switch to a long pulse indicating GPS signal lock Note depending upon antenna position it may take longer to lock onto the signal The amber LED indicates network activity 3 SET UP AND CONFIGURATION Copy the TIMENET Config exe program from the TIMENET USB key onto a Windows PC and connect the PC to the same network as the TIMENET The default IP address of the TIMENET unit is 192 168 42 7 this is also printed on the serial number label on the underside of the unit Configure the network settings of the PC to the same domain e g 192 168 42 100 Run the TIMENET Config program The default IP address will automatically appear in the IP address field You can also use the Scan feature to locate the TI
Download Pdf Manuals
Related Search
Related Contents
DLG/2011/217 Ristrutturazione piano terra Sede Municipale. Presa Mounting and Operating Instructions EB 2555 EN Manual de usuario Untitled - Glideaway DE EN ES FR IT PT SE Type C… Operation Manual WatchNet Player User Manual Catalogo uCables.com Diptico Iveco C.indd Copyright © All rights reserved.
Failed to retrieve file