Home
        CONTROL PANEL CA-64
         Contents
1.              enter time  max  4h33m03s   Defer auto arm XXX     K    for  h m s                         Figure 11    ARMING MODE       This function provides for selection of a special mode of arming  There are three  options of arming modes       Full     Stay      Stay  delay   O  off   Details concerning the use of functions are discussed on page 16 of this Manual   Section    System Arming        Upon selection of the arming mode  the control panel returns to the user function  menu  thus enabling the selected partitions to be armed    Exiting the menu without arming  key    will cancel the selection made by using this  function     select and press      code   Arming mode  gt  gt   Arming mode  T  Full    Figure 12                               CHANGE OWN CODE    This function makes possible to change the code of the user  who called this function   To increase the safety of the system  it is recommended to change user code  periodically    The control panel requires code change from a newly entered user  who has the right  to change it  because his her code is known to the person  who entered the new user  to the system   Each time the new user enters his her code  the message    Change  code    appears on the display  This message appears until the code is changed to  another one  Access to rights and partitions assigned is not blocked when the code  remains unchanged     The requirement of code change may be arisen by guessing this code by another  user  The situation
2.      When the arming function  access code   or quick arming O   is called  the following  message appears on the LCD display       Vibration sensors test xx s  1   arm     where the xx field indicates the number of  seconds before the end of test    During the test  the control panel is waiting for the violation of vibration zones in  a given partition  If all the vibration zones of the given zone are violated  the alarm  control panel switches over to counting the exit delay time and arming the system  In  case some of the vibration zones are not violated during this time  the control panel  will display a list of faulty zones  number and name of zone  and will not arm the  system     Operation of control panel CA 64 17    Pressing the digit 1 key during the process of countdown will interrupt the test and  arm the system in normal mode  while pressing the   key will make it possible to  cancel the arming    Arming the system from the partition keypad will bypass the testing of vibration  sensors in the particular partition     Also  special control ways of partition status are possible    e partition arming and disarming by means of timers  Timer is an internal control  panel logic unit  which measures time  Timer operation is programmed by the  service    e partition arming and disarming by means of a    partition user timer     This timer  may be programmed by the user  without necessity of asking the installer  or the  service  for that  There is a single timer of this 
3.    Masters LS xxx  E service      Users xX graph    Zone bypasses    Set time XXX    Failures oo  Reset zones a  Change options Bl  xxx master  Take SM  service mode  over    Downloading     o   8      Table 1       BLOCK DIAGRAMS AND DESCRIPTION OF USER FUNCTIONS    User functions are shown in block diagrams  The texts  which appear on the LCD  keypad display  or name of list accessible in the form of menu for scrolling  are  shown in frames  The list is scrolled by means of keys  ff and 4  The function  which  may be selected  is marked with arrow at the left hand side of the function name  on  the keypad display    gt  Function name   Press key   or  gt  to move to the next block  in the diagram  function execution stage  according to direction shown with arrows   The return from some menu levels to previous menu level is possible by pressing the  key marked      Pressing the key   at each menu level means  mostly  abandoning  execution of the function selected and return to the main menu  The user must be  authorised to use the function to make it displayed by the control panel    Execution of each function is confirmed with proper message  which is shown with a  symbol at the block diagrams describing functions       end of function execution     the control panel displays a proper voice  message and returns to the basic status     22 Usre s Manual CA 64 SATEL    DATA ENTERING    Some functions require typing of a new code or a user name  The way of entering  new data th
4.   Erase DALLAS  Save  y press    K Read card for      Read card for Card read  the first time the scond time      Figure 15    Note  The way of reading in and removal of DALLAS chip are identical with  proximity card reading in and removal  see     Notes    in description of  function USERS      USERS    The function that gives the right to enter new alarm system users  Define the user  authorisation and type when entering him to the system    The type is an additional code property to be assigned to an ordinary user of the  alarm system  If proximity card readers are installed in the system  read in the card   which will be used by the new user     Description of user functions 29    Authorisation  rights  list to be assigned to the new user is as follows  it indicates  the functions  which the user will be allowed to execute        Arming   Failures viewing     Disarming   Events viewing     Alarm clearing   Zones resettings     Object alarm clearing   Options changing     Other alarm clearing   Tests     Arm deferring   Downloading     Code changing   Disarming after     Users editing   Voice messaging clear     Zones bypassing   Guard64 using     Clock setting   Access to blocked partitions    Note  The right    Switch off for somebody else    defines whether the user always    may disarm  marked option  or only when he previously armed by himself   marking cancelled      The list of user code types is as follows     1   2   3     Normal     basic code type assigned to th
5.   s Manual    EXPLANATION OF SOME TECHNICAL TERMS   All definitions are valid for the alarm system based on control panel CA 64     STARTER    FLASH  memory    2402 memory  DLOAD64  GUARD64    subsystem    partition    zone    zone violation    output    relay output    bus    expander    The program activated in the control panel after power supply  switching on  the purpose of which is to check correctness of the  basic program stored in FLASH memory and make possible to load  a new control panel software version into this memory     The memory  where the control panel basic program is stored  It is  cleared electrically  and its contents may be changed with the use  of computer     Additional non volatile memory  where important system  parameters are stored  for example  administrator codes  etc       Computer program that enables programming of control panel  settings with the use of computer  so called service program     Computer program that enables operation of the alarm system with  the use of computer  so called user program     The group of partitions being an independent alarm system  Eight  groups of this type may be created on the basis of control panel  CA 64     The group of zones supervising separated part of object  arming  and disarming is carried out simultaneously for the group  The  alarm control panel CA 64 allows creating of 32 independent  partitions     Pair of contacts at the control panel main board or module board   connected to the control panel
6.   the installer may program audible signalling in an LCD keypad for the  following situations       Alarm for a partition     continuous sound for the total alarm duration  time  programmed by service        Fire alarm     series of long sounds every second for the total alarm duration     Count down of time for entering     short sounds every 3 seconds       Count down of time for exit     long sounds every 3 seconds  completed with  a series of short signals  for 10 seconds  and a single long sound  The way of  signalling of    time for exit    informs that the count down is finishing      Signaling the auto arming delay time countdown  timer controlled partitions     a series of 7 sounds  of diminishing length        Gong in the LCD keypad     five short sounds     this is a response to activation  of some detectors when the zone is disarmed     THE USE OF LCD KEYPAD    Operation of the system from LCD keypad starts with entering the user CODE and  pressing the key marked   or    Note that the control panel response  functions  accessible  after pressing the   key is different from that generated after pressing the    one  The specific feature of the control is the dynamic changing of the accessible  menu  dependant on the system programmed parameters  as well as on the  authorisation level of the user who entered the code  The designers of the control       8 User s Manual CA 64 SATEL    panel have chosen such a way of its control to facilitate operation by users who do  
7.  APPENDIX D     examples of keypad operation        sessessesseseosoesessossesoessesoosoesessossesoessesoesoesessossessossesoesseseesseseseo 43    APPENDIX E     functions of keys and lamps      ccoccooncooncnnncnnccnnononononononnononocono conc cnc non oooncoonconocononccono coronan cono cns 50    Operation of control panel CA 64 3    INTRODUCTION    The control panel CA 64 is intended for controlling operation of alarm systems  which  monitor and supervise the security of medium sized and large objects  Supervision is  not limited to protection against burglary  but may also include monitoring the correct  functioning of the object for 24 hours per day  The status of the alarm system is  monitored continuously  Violation of any alarm system component results in a so  called tampering alarm  The control panel responds to signals from individual  detectors and decides whether to activate alarm or not  Since various detectors may  be connected to the control panel  type and way of alarming depends on the control  panel software installed  the control panel may respond in a different way to a signal  from fire detector than to a signal from a water level detector     The control panel allows grouping of detectors  zones  to obtain so called partitions   as well as free choice in determination  which partition is to be monitored  armed    Activation of any detector from such a group  called    zone violation    in the below text   may trigger an alarm  High flexibility of the co
8.  by means of bus   to which the  detectors are connected  The control panel monitors detector  statuses via the zone  Monitoring of 64 zones is possible     Change of zones status when the detector is activated  for  example  zone contact opening or shortening  change of detector  parametric resistance      Pair of contacts at the control panel main board or expander  module boards  where the voltage is controlled by the control  panel  It is possible to control 64 outputs  including relay outputs      Electromagnetic switch located at the expander board  controlled   switched over  by the control panel     The group of wires  to which the modules operating with control  panel main board are connected  The control panel CA 64 is  provided with three buses  One bus is used for connecting LCD  keypads  and two buses     for connecting expanders     Electronic device which extends control panel features  There are  expanders to increase number of control panel zones or  and   outputs  Also  partition keypads  coded locks and proximity card  readers are included  It is possible to connect up to 64 expanders  to the control panel     CA 64 SATEL    Appendices    43    APPENDIX D    This appendix contains descriptions of examples of activities to be carried out when calling some  user functions  The first column indicates which keys must be pressed  the second column  contains description of operation called  and the third one shows texts displayed on the LCD  keypad after the oper
9.  that the user code is guessed may occur when entering a new  user or during normal code change procedure by any system user  The guessed  code is rejected when changing the code  and    the owner    of this code is asked to  change it  see  Notes  page 22   Also  the control panel suggests to change the code  for the users assigned with the type Temporary  renewable  The function does not  accept a code already existing in the system     Description of user functions 27    It is possible for the service to activate the option of blocking creation of codes easy  to guess  When this option is activated  the control panel does not allow to create  codes of type  1111  1234  1122 etc  These codes are rejected  and the control panel  waits for another combination of digits     Notes     The control panel does not accept the code identical to the old code as a new  one       Change of a guessed code requires more complicated procedure     code change  with confirmation     Figure 13      The administrator may confirm user code change  with his administrator code    and the administrator code must be confirmed by the service personnel  with the  service code   The use of the service code is possible after unblocking the  service access by the administrator     Basic procedure   type new CODE  code        Change ovn code New code    xxx   K    Figure 13                                     Change procedure for a code guessed     message   press   type new code  code       gt   Code r
10.  the arrow key f  each single pressing deletes a character at the  left side of the cursor   Press arrow key YU to enter space at the left side of the  cursor  use arrow keys    and    to move the cursor under the user name  backlighting the position to be changed  To change the character at the  position indicated by the cursor  repeat pressing the key with the proper digit so  many times  until the proper character appears  Then  move cursor to the next  position and repeat the procedure     Pressing   accepts data entered                                                                                         Pes Hi           8   l1      e 4 1  AlalAla Bb  Clc   Clel2  CAE  G gl Hlhi li  4  Jij  KI kIiLit lel  5  Mi  m  N  n        R O 0o    6 6  Pps  Qe  qe Re Ss Ss  17  Tit  U u Viv  8  W w X x Y y Z z Z       9    4 deze   E ee   gt        D  EE 8                                  Table 2 Characters accessible for the text mode of data entering     Description of user functions 23    DISARMING    The function allows disarming in a single partition  several partitions selected or all  partitions accessible to the user  from a specific keypad           select  code   Disarm all mark selected   K    Disarm selected What to disarm  d          Partition name graph       code xP   Disarm    Figure 3             CLEAR ALARM    The function clears alarm signalling and clears memory of alarms occurred since the  last alarm memory clearing  Alarm memory clearing does not include th
11. 1 to 4  event type numbers according to the list given below      List of event types     1  Zone  amp  tamp al   Alarms for zones  tamper alarms   2  Other alarms   Other alarms  Fire  auxiliary  technical alarms  no sentry  round    3  Arm Disarm Clr   Arming and disarming  alarm clearing    4  Zone bypasses   The use of function  zones bypass      bypass cancelling  after disarming    5  Access control   Use of keypads and proximity card readers for controlling    electromagnetic door locks  door status monitoring   temporary bypass of partitions     6  Failures   Failures  Technical problems in the system  restarts of  modules    7  Functions   Functions  Calls for user functions to control the operation  of the control panel    8  System   System events  Service mode  clock programming  etc     Note  The messages about the following event types are not displayed in the  event lists on th LCD keypad     Attack alarm  PANIC      Silent attack alarm  silent PANIC      Forced activity alarm  DURESS type code     No additional message is displayed when exiting the function     Description of user functions 35    code   mark types    Event classes  oul  select in sequence Event type name    Select events mark partition                         Events                Select part   4    gt  Part  events  to    select   View Zone name graph  Selected press   to exit  All DD MM HH mm IDEN        Event name                                                    Figure 20    Note  The lis
12. 12345 6 7 8 9 0 I 2B 4 5       Dasa tam  all  Disarm selected             17 1819 02122324 5627 28 2 30 31    CONTROL PANEL 132 0      When you press key   or all partitions armed and  accessible for the user will be disarmed     If only one partition is armed  it will be disarmed just after pressing key    together with displaying the  end message    If an alarm is signalled for the partition  it may be cleared together with disarming        Indication of the function Disarm selected  Calling of the function     12 3 4 5 6 7 8 9 0 I 2B 4 5       What to disarm   Workreom 1                Scroll the list with partition names  Press one  of these keys so many times as you need to  display the name of the partition required   partition 2     Book keeping      SERWCE O          17 1819021234 5627 282930 31    CONTROL PANEL     1 32    Q  ZONES           1 69    After the function is called  the control panel displays  partition names  factory set or entered by the installer    which the user may disarm  Press key   to move to  the graphical mode of partition selection  selection  in the graphical mode is carried out in a way  identical with arming           12 3 4 5 6 78 9 0 I 2B 4 5    Mark the partition selected for disarming  fj mark  at the right hand side of display  using any            a What to disarm     numeric key      Book keeping                SERWCE             17 1819 2222324 52  27 28 9 39 31    CONTROL PANEL     1 32    Q    ZONES 14           You may select fo
13. 19 DARBA 2 2 27 22 2 30 31    CONTROL PANEL    CA     1 2 3 4 5 6 789 01 2 B 4 B    Zone bypass 01       DUAL cont  toem    ISERMCE O  17 18 19 02122324 5627 823 30 31    CONTROL PANEL     1 32  0     CA 64   zones    Zone bypass 04   Entrance door       123456 789 01 2 B 4 B    Zone bypass 49 0  PIR  secre  Oia ce    17 1819 02122324 25 2  27 28 2 30 31  CONTROL PANEL    Appendices         NOTE     Example 4     49       End of selection and bypassing of status Pon pe A ee ee za ia    monitoring for all zones  detectors  marked           Zone bypassed  Saver              serwce O       17 18 19 02122324 25 2 27 28 2 30 31  CONTROL PANEL     1 32                   Zone bypass is cancelled after disarming of the partition  to which the bypassed Zones belong     ZONE STATUS VIEWING    function called by long keeping pressed of the key        12 3 4 5 6 778 9 01 2 B 4 SE           Call the function of control panel zone status  viewing  Keep pressed the key for approximately  3 seconds     information on first 32 system zones  will be shown in the graphical mode display              17 1819 2212 23 24 2 2 27 28 22 30 31  CONTROL PANEL     1 32    CA 64  zones 164       365 0     The LED 1 32 being ON indicates the set of zones  the  status of which is shown on the display  Symbols  representing zone status are described in the User  Manual  CA 64     description of function Tests          Move to the second ZONE set display  ZONES AAA a    33 64  Use any arrow key to do that  Yo
14. 20  BLOCK DIAGRAMS AND DESCRIPTION OF USER FUNCTIONS                eee  see enae eee nasa a nana azaacaacwae 21  DISARMING 4a asza Matai e GZ RA RO W Sa   A  23  CLEARATARM ad RAR OOOO LO WAR ZNA WO AO SRB AA BARA 23  CLEAR OTHER  ALARMS   z O WA  A GOA dE R AO id 23  PV X0  SAO   0 91 PRKYECEJ LEZ 23  ARM Ryk NA ot OOO TAk o A O o Z ISA ZE Mn tak ote cer a lO 24  ARM  2   CODES    a aid ii a AO ieioea aar eds Ena ea ON a i o reris 24  DISARM  2  CODES  iii T E E 24  DEFER AUTO ARM viciosa indiana eS NERSE E ESEK P a da Taek es C Tas Eskri REES 24   SET AUTO ARM DELAY 4 3 sciccccscedcievessncesvuseccesatscciveedcedeusstcacsecchdesshccteedubectsadaiastssdetceddhcctsedvisetsedseceuesuseeseucs 25  ARMING MODE sviesesne dekio anr eaa ie aer iKa a AA d Eeer dak Eer eak ra Seip a eaei ak 26  CHANGE OWN CODE sd e oertain Wda arasa a ni aa r eaid aard ZAC 26  MASTERS l   27  USERS  lt a 28  ZONE BY PASSES vio ias 32   SET FIME OO 32  FAILURES icon EE RRC 33  EVENTS aoc sh Scent oe Soe A ANIE dh ives a E OK A Steere Skeets 33  RESET  ZONES ua ita 35  CHANGEZOPTIONS 0 tite O ROG OWO ARGE ada 35  TESTS zzo RE AO A RAZEM AO RAA R ROCK WOW O A M eo AG SEN 36  SERVICEACCESS A acim tie Oo old eR eas tec ahs aCe eo A AEO DO at es Shed vine es OE 39  SERVICE MODE  ib 39   SM TAKEO VIER iii e bs ate 40  DOWNLEOADING sos E Oi ehh al de 40  SUMMARY AAPP O 41  APPENDIX C   explanation of some technical terms                 ssccscssscssscsssssscssscssscsecssessecssecssssscssssssssssssssesens 42 
15. CONTROL PANEL  CA 64     software version 1 03 xx     User  s manual    Przedsi  biorstwo Produkcyjno Us  ugowe    Saded     GDA  SK          ca64u_e 06 01    USER   S MANUAL Przedsi  biorstwo Produkcyjno Us  ugowe    CONTROL PANEL Bare  June  a 2001 POLAND    Thank you for choosing the product offered by us  High quality  large number of  functions and simple operation are main advantages of the control panel offered by  SATEL s c   Hoping that you will be fully satisfied with this choice  we declare to  provide you with professional assistance and information on our products  We would  like to inform that  besides control panels  SATEL s c  produces many other  components of alarm system  Look for detailed information on our full offer in retail  outlets dealing with our products  at our website www satel pl or directly at out site  tel    58  32 09 410  fax  58  32 09 401     We kindly ask you to read the entire Manual carefully  since detailed knowledge on  the control panel functions will allow you to fully utilise all included possibilities  This  Manual is very general  and deals with the basic operation of a typical alarm system  installation  The control panel may carry out functions that are nor related directly to  monitoring  We are not able to foresee all possible ways of use of all the control  panel functions available  The use of all control panel functions and efficiency of  operation of the entire system depend on the installation itself and the software  in
16. HH MM everyday weekly                Save Tue HH MM HH MM          Wed HH MM HH MM   Thu HH MM HH MM   Fri HH MM HH MM   Sat HH MM HH MM   Sun HH MM HH MM  Save                                           Figure 22    ULE     The function allows performing various operations for checking the system operation  correctness          Arming status     Checking the current status of partitions accessible for an  individual user and operated from the LCD keypad  The partition status is shown  in the form of symbol  mark  adjacent to the number  numbers around the display  screen  which corresponds to the partition number in the system  The installer  assignes symbols  marks  to particular situations  It is possible to read the  following information on zones          Description of user functions 37    b  temporary partition bypass        entry delay    w  exit delay  less than 10 seconds     W   exit delay  more than 10 seconds     Cc   zone is armed      zone is disarmed    Zone status     checking the current status of each zone in partitions accessible  for an individual user  Zone status is shown in the form of a symbol  mark   adjacent to the number  numbers around the display screen  which corresponds  to the zone number in the system  The installer assignes symbols  marks  to  particular situations  Two sets of information on zones are displayed  first set for  zones 1 32 and second one for zones 33 64  Two green LEDs next to the display  indicate  which set is displayed curr
17. L PANEL 12 07  CA 64   zones 161    48    User s Manual    Example 3  ZONE BYPASSING    Bypass zone No  4 named Entrance door and zone No 49 named PIR secr office     the user code  38407     38407  Type code     calling the user function menu     or       Hor       or       or                   12 3 4 5 6 78 9 0 L RBH 5 Lu    PATM r  Change own code   17 1819 02122324 52  2 28 2 39 31       CA 64 SATEL    CONTROL PANEL     1 32  0     CA     ZONES    The use of most user functions  except functions  called with longer pressing of a single key and the  function of quick arming  starts with entering code and  pressing key    or     example 1 and 2      Scroll the list with accessible function names   Press one of these keys so many times as  you to display the name of proper user  function next to the arrow     Select function indicated with arrow     moving  to the stage of zone  detector  selection to be  bypassed     Scroll the list with zone names  Press one of  these keys so many times as you need to  display the name of the first zone to be  bypassed  Entrance door  next to the arrow     Mark the zone selected for bypassing  IJ mark  at the right hand side of display  using any  numeric key     Scroll the list with zone names to select next  zone  detector  for bypassing  PIR secretary  office     Marking of the Zone selected for bypassing                                                                    123456 789 01 2 B 4 5  Change own code    gt Zone bypasses   17 18
18. asters graph master  Panel version                                  Figure 23    SERVICE ACCESS    The function allows the installer to access the system by means of the service code   It is accessible in the administrator menu only  It requires data entering     number of  hours  when the alarm system will be at installers  Service  disposal  The access to  the system is blocked after this time elapses    Typing    zero    with this function  in place of number of hours   when service access is  opened  automatically blocks the access    Access time is counted down whether the service mode is started or not  Access time  counting down may be interrupted by power supply disconnection  mains 220V and  battery  only  With this function you can check how much time is left  from the access  time limit given by the administrator      indication  00    means that the last hour is  being counted down     type number of hours  1 99   code k     gt  Service access      b  Service access XXX TPR K  time  h                                         Figure 24    SERVICE MODE    The function starts a special control panel operation mode  The list of the  Service  functions    is accessible in the separate instruction manual for the installer  The  control panel does not signal alarms from most of zones  including tamper alarms   it  responds to violation of some zones armed for 24 hours and alarms from partition  keypads and coded locks  functions of long time key pressing   In this operati
19. at relate to system users is described below  When changing the code   the control panel does not show the old code  unless the user has not changed the  code assigned for him by the person introducing him to the system yet  But the old  name always is shown on the display when changing the old name  The user name  entered appears in selection lists  printouts and when viewing the event memory in  the computer     e new code  time limit  numeric data are entered by means of numeric keys   Arrow keys are used for modification of numbers being entered  Below the text  field  where digits entered appear  the cursor  dash  is seen  Arrows     and  gt   are used for moving the cursor to show digits in sequence  Press the key with  digit to enter the digit required at the left side of cursor  and press the arrow ft  to delete the digit at the left side of cursor  The arrow U change cursor type      blinking  dark rectangle appears  Cursor of this type allows changing the digit  above the dash to the digit typed at the keyboard  Press key   again to return  to the previous cursor type     e user name  user name is entered by means of numeric keys  which change  their meaning and allow entering text data  letters  to the control panel  Table 2  contains characters accessible at the keypad keyboard  Subsequent pressing  of the key with a digit changes the characters in a cyclic way  The new user is  entered by changing the factory entered name  You may delete the old name  by pressing
20. ation is executed and the comment on the situation obtained  Since the user  function menu depends on software installed by the installer and specific user authorisation   texts shown here are for orientation only and may be slightly different in practice     Example 1     1111     NOTE     ARMING  part I     partition No  2 named    Book keeping     belonging to the subsystem 1  user     the  subsystem master     12 3 4 5 6 78 9 01 2 B 4 5                Enter a user code  the factory set master code  Code recogni zed  for the subsystem 1   Sarel    change it        Also  you can enter the code of any user  who   sag x i 17 1819 02122324 2 2 27 28 22 30 31  has access to the partition 2 and authorisation oa  for arming  cet       This message is displayed when the user has the right  to change the code and should make this change  see  User Manual  CA 64  description of function Code  change         12 3 4 5 6 78 9 0 1 1 2B 4 5    Confirm the message  SArm all  i Arm selected    17 1819    2122324 52  2 28 2 30 31    CONTROL PANEL 12 07  64   zones                        a    If you press key   or     all partitions accessible for  the user will be armed     If some of partitions accessible for the user are already armed  the control panel will make  available the functions of disarming only  but if just one partition is armed  it will be disarmed   To arm the remaining partitions  first call the user function menu by typing CODE    see  continuation of the example  ARMING  
21. der of zones  or partitions   in the system  The information on alarm activation is stored in so called    temporary  alarm memory     until the contents of this memory is cleared by an authorised user   see    Description of User Functions     gt  Alarm clearing   The contents of this memory  may be checked many times after resetting the alarms  until it is deleted     10 User s Manual CA 64 SATEL    PARTITION KEYPAD       ALARM    ARMED    FAILURE       Figure 2    Partition keypad is provided with 12 keys with permanent or temporary backlighting    service setting   and three LEDs described as follows    e ALARM  red      steady light indicates an alarm in the partition operated with this  partition keypad  and blinking indicates that alarm occurred in this partition earlier    e ARMED  green    steady light informs  that the partition assigned to this keypad  has been armed  The LED blinks when the time for exit is being counted down    e FAILURE  yellow      the LED blinks when a technical problem has been detected  in the system  Check the LCD keypad for the type of failure  Indication of this  LED relates to the entire system  not only to the partition operated with this  keypad  Arming of a partition switches off the LED  and disarming causes the LED  to lit again     When all of three LEDs  ALARM  ARMED  FAILURE  flash in sequence  this  indicates missing communication between the keypad and the control panel  This  situation may occur when program STARTER runs in th
22. e  max  4h33m03s   E Defer auto arm xxx   k      for  h m s                Figure 10       SET AUTO ARM DELAY    The function puts off  delays  the arming of a timer controlled partition  auto arming    It is intended for programming the value of time interval by which the moment of  automatic arming of a partition is to be delayed  The maximum postponement time  value is 4 hours  33 minutes and 3 seconds  Entering a higher value will set the  maximum permissible value  while entering the zeros alone will restore the partition  control according to the installer s settings  Operation of this function pertains both to  the    Partition user timer    and the    Timers    programmed by the installer    The postponement time is programmed individually for each automatically controlled  partition     The function is available in the user menu if the user is authorized to get access to at  least one partition for which a non zero    auto arming delay    time has been set   service setting   The value of such a delay may vary from 1 to 255 seconds   Activation of the timer controlling the particular partition triggers the process of  counting the auto arming delay time  Then  countdown of the partition exit time takes  place  if provided   followed by arming the partition        26 Usre s Manual CA 64 SATEL    select partition                   code x          Set auto arm d   gt  Paritonamen t nm     numbers of auto   Partiti matically controlled  artitio name m partitions         
23. e code  select in sequence Telephone code  XXX  Code mark selected  Telephone code User partitions    select  Partitions    gt  Partition name graph User type  8  Type iQ  Ha Type name   Rights type name  Name  gt   User name  g mark selected  Existence time User name Rights  2  Bypass time type number of days  2 255  Right name  Read prox  card Code existence me  Erase prox  card time  d  Read DALLAS press digit 1  Erase DALLAS type time in minutes  1 109  Erase card   1 Yes                                  Part  blocking    time     m    XXX                       Read card for    the first time                Figure 16      Read card for  the second time                 press         Card read                         32 Usre s Manual CA 64 SATEL    Notes           Telephone code    is to be typed in this case only  when the user wants to use  the control panel function    Answering phone calls     see Operation of control panel  CA 64       The card may be read again after minimum 2 seconds from the moment of card  removal from the reader       Actual removal of a card from the control panel memory takes place at the  moment of exiting edition or accepting the user function with the function    Save          The way of reading in and removal of DALLAS chip are identical to proximity card  reading in and removal     ZONE BYPASSES    This function bypasses zones from the moment of the function entry  The control  panel ignores all information coming from detectors connected t
24. e code by a user who accidentally  guessed  the code     NOTE  With a big number of users it is advisable to use longer codes  at least 5 digit  ones  to reduce the chance of  guessing  the code of another user     CODE LOCK    The coded lock looks similarly to the partition keypad  The code lock is provided with  12 key backlit keypad  Keypad backlit may be permanent or temporary  service  setting   The lock is provided with three LEDs marked as follows     e STAND BY  green      LED is on when the lock is operated by the control panel   and the door may be open    e ACCESS  red      LED is on when the door lock is being unlocked    e DOOR  yellow      this LED shows the status of zone  which monitors the door  status  The LED is ON when the door is open     When all three LEDs  STAND BY  ACCESS  DOOR  flash alternately  that means  there is no communication between the code lock and the control panel  This  situation may occur when program STARTER is running in the control panel or the  cable connecting the code lock keypad to the control panel is damaged     Operation of control panel CA 64 13    The basic code lock function is to control the access to the room  where the door  provided with electric catch  bolt or electromagnetic interlock are installed  Also  the  lock may be used for partition checking when sentry round in the object     To open the door  type CODE at the lock keypad and press key   or x  The user  must have access to use this code lock     gt  CODE   d
25. e control panel or the cable  connecting the partition keypad to the control panel is damaged     There is a possibility to program a partition to be armed or disarmed after entering  two codes  service setting   In this event after entering the first code  LEDs ARMED  and FAILURE start to blink  and the control panel waits for entering the second code     Similarly to the LCD keypad  the partition keypad may generate audible signals  This  way the control panel confirms the function called  since there is no display at the  partition keypad     One long beep   refusal of arming   the zone   which shouldn t be violated at  the time of arming  is violated  option    PRIORITY         Two long beeps     the code is not known to the control panel     Two short beeps     acceptance of the first of two codes needed to arm or  disarm     Three long beeps     the code cannot control this partition     Three short beeps     confirmation of partition arming and disarming     Three pairs of short beeps     it is necessary to change the code   for example   a user  when changing his code  has entered an identical combination of digits  as in the code of another user  or end of code validity is approaching     Operation of control panel CA 64 11      Four short beeps and one long beep     the confirmation of the performance of  acontrol function  code change and of a guard round      Five short beeps   the dependent door are open   the door control has not been  performed  To operate the 
26. e event  memory  where the facts of alarm occurrence and cancelling are registered and kept  fully described  The function is executed automatically  when the system is armed  and alarm occurs  after the code is entered and key   is pressed  Then  the control  panel displays the menu of the function Disarm  and  after this function is executed  it  displays an adequate message        code        Clear alarm  gt  K                   Figure 4    CLEAR OTHER ALARMS    The function allows cancelling alarms from other subsystems  to which normally the  user has no access        code x x    Clear other al  r K                   Figure 5    ABORT VOICE MESSAGING    When this function is called  messaging by telephone is stopped   the control panel  should ring off  If the telephone line is still occupied  that means  that messaging for  the partition non accessible for a given user is carried out    Messaging by telephone may be cancelled automatically together with an alarm  clearing  service setting      Note  If the installer has not specified the partition for a selected telephone  number  the users of which can cancel messaging by telephone  the  procedure of messaging by telephone to this phone number will be carried  out till the end  without possibility of stopping it        code      Abort voice m   gt    K                   Figure 6    24 Usre s Manual CA 64 SATEL    The function allows arming of a single partition  few partitions selected or all partitions  accessible to 
27. e for the user is already armed  he she may arm other  partitions when he she types at the keypad      gt  CODE   arming by selecting    arm    from the function menu  see   Description of User functions      There are some special methods of system arming possible in a partition   available from the LCD keypad        activate without internal zones     the control panel does not respond to  violation of zones defined as internal by the installer  This possibility allows  user to stay in the object and arm  The object is protected externally in normal  way  and the system performs all functions programmed      arm without delayed zones     arming is performed in a way similar to the  previous case  but additionally the delayed zones act as immediate ones     To arm the system in one of the presented modes  proceed as follows   1  Enter ACCESS CODE and press the   key   2  Call the    Arming mode    function     3  Using the   and Y keys select one of the suggested arming modes and press        4  Call the    Arm    function and select  highlight  the partition to be armed   5  Press the   key     Disarming the partition will cancel the special mode of its arming  To re arm the  partition in a special mode  the procedure described above must be repeated     The procedure of arming the system from a LCD keypad in the partition where the  type  10     24h vibration    zone belongs and the testing function of vibration sensors  is activated  service setting  is slightly different
28. e fu      Figure 22     2  Then  select operation mode  daily or weekly     3  Programming of timer on and or off time is the next step  To do this  select the  function  for daily mode timer   gt Cod  HH MM HH MM and press key   or      the  message    Timer switched on every day  HH MM    on the display    4  Then  enter hour  HH  and minutes  MM  of timer switching on  Press key f or U  to enter hour and minutes of timer switching off  To accept data entered  press key    36    Usre s Manual CA 64 SATEL       The display will show the name of the timer set data programmed  For a weekly  cycle timer  the time of switching on and or off is programmed in the same way   but it should be done for each weekday separately  When you enter only    nines      the function will not be active  For example  the timer may arm only at the  determined time  but disarming must be performed by the user himself  automatic  partition control may be activated in some weekdays only       In order to save timer settings in the control panel memory  exit option    programming with the function SAVE     code                        Change options   Keypad chime mark selected t K  Outputs chime  gt   Outs chime bl            oul    Part  timers Code name graph  in Partition name f    A Z     gt     Active      lt  lt    Part  timer active     A AR NEK   everyday     weekly  press    or U to change     ii Timer type                                                           Evd  HH MM HH MM Mon HH MM 
29. e user   Single use     code for use once only     Temporary renewable     code  for which the validity time period is given when  entering a new user  Before the validity period elapses  the control panel reminds  the user with such a code that he must change the code  After this change  the  validity period is counted down from the beginning  After this user code type is  chosen  when entering or editing   the function Validity period appears in menu   see Figure 16   where number of code validity days should be defined       Temporary non renewable     code  for which the validity time period is limited to    the number of days specified when entering a new user  After this user code type  is chosen  when entering or editing   function Validity period appears in the menu   see Figure 16   where the number of code validity days should be defined   Validity period may be changed for this code type by the user  who entered a new  user  or by the administrator or the service       Duress     code similar to the normal user type  but the use of this code generates    additional event  which is sent to the monitoring station     Alarm     forced activity       At the same time  this code may activate a special alarm adequate for the  situation  programmed by the installer   This code is intended for use in the case  of attack       Monostable output     code  which switches on the    MONO switch    type outputs     This function may be executed in partitions assigned to a code o
30. ecognized       Change ovn code F  gt   New code  XXX  change it                                                   Type confirming code press digit    1     Enter xxx  gt  Change  1 Yes         gt  K  confirming code User name                         Figure 14    MASTERS    This function is used for entering the new user with administrator authorisation   changing data related to the existing administrator  or for removing the administrator   Only the installer  service  is authorised to use this function  Only one user with such  authorisation may be assigned to the subsystem  The list of rights  which may be  assigned to the administrator  is identical with the list shown in the description of the  function Users  The changes made become valid in the system since the moment of  exiting the function using the command    Save        28 Usre s Manual CA 64 SATEL          Code x    select according to subsystem no   n   Masters New master  n  T                                  Edit master Remove master  n      gt  K  Remove master          select     Edit master  n  t  New master                         enter code  Master code  XXX  mark selected    select in sequence i Rights  T  Code                                                                                                                           Right description  Rights enter name  Name  i4      b gt   Master name  XXX  Read prox  card Master name    Erase prox  card press key with 1    Read DALLAS Erase card   1 Yes
31. ection of access to the service mode and prevention of entering codes by  unauthorised persons are main purposes of that     An additional possibility is to assign specific control function to a code  This function  will be executed after the code is followed with the   key  see  Description of User  functions   Users      The installer  using the service code  defines administrator codes and names  one  administrator per each subsystem   as well as he defines their rights     The administrator has the right to enter ordinary system users  He provides them with  rights  type and defines the partitions  to which the users will have access  Also  the  ordinary user may have the right to enter other users  New user may have access to  these functions and partitions only  to which the user  who enters the new code has  access     Note  If the user has authorisation for changing the code  he should change it  after first usage of the code  The control panel reminds by means of a  message on the keypad display and an audible signal that this operation  should be performed  service setting      The system stores the sequence order of entering users into memory  The person  with authorisation to enter and delete the users may remove from the memory the  users entered by him her or his her subordinates only  The service has the right to  edit all administrators  as well as to change codes   The administrator has such rights  for users in his her subsystem  Ordinary users have rights t
32. el the timer                                  type code  Enter the  second code             Figure 9       Description of user functions 25    controlled arming until the particular timer is activated again  Operation of this  function pertains both to the    Partition user timer and the    Timers    programmed by  the installer     The function makes it possible to select the partitions  where the countdown of  the    auto arming delay    has begun  This very feature distinguishes the said  function from the described below user function    Set arming postponement     which  gives access to all the partitions armed automatically with time delay which are  available to the individual user  In view of a low value of the auto arming time  max   255 seconds   it is important that a quick option of the partition arming postponement  be available in case it is necessary to stay inside    Upon commencement of the countdown  the control panel presents on the LCD  keypad display the partition name and the delay time which remaines to arming  If the  time is simultaneously counted in a few partitions  the display shows the name of the  partition which will be armed first     The postponement time is programmed individually for each partition for which the  auto arming delay countdown has begun     select partition                   code x     Defer auto arm    gt Partitio name n  n m     numbers of auto   Partiti matically controlled  artitio name m partitions                enter tim
33. ently  Upon starting the function the status of  zones 1 32 is displayed  Press any arrow key to move to the display of statuses  for zones 33 64  to find a zone number  add 32 to the number next to the symbol    Press any arrow key to move to the display of statuses for zones 1 32 again  The  amount of Information accessible depends on the type of detector connected to  the zone  Detectors configured as double parameter provide most detailed  information  It is possible to read the following information of zones     b  zone bypass       failure  long violation    f   failure  no violation     S  tamper alarm    A  alarm    O  zone tamper    e  zone violation    s   tamper alarm memory   a   alarm memory        zone OK     Note  Symbols shown above are factory settings  which may be changed  The  installer should inform on how individual zone and partition statuses will  be marked on the display     LCD keypad status     checking the status of anti tamper contacts in the keypad  casings  Symbols displayed at the keypad screen are as follows       correct status     e  contact violated   X   keypad replaced  verification error        keypad is missing     Expander status   checking the status of anti tamper contacts in expander  casings  first bus expanders and second bus expanders are checked separately   On starting the function the status of the first expander bus is seen at the display   LED marked 1 32 lights   Press any arrow key to display status of the second  bus expa
34. er bus    1 3 4 5 91 11 2 B 4 5 16          8          c                    Q    scrolling names of partitions   where alarm has been activated       8   when pressed for 3    seconds  gong signalling in  KEYPAD is switched on off           keypad name  when pressed for  approximately 3 seconds        o     scrolling names of zones     which triggered alarm       when pressed for 3 seconds   FIRE ALARM is activated     when pressed for 3 seconds   O   when pressed for 3 PANIC ALARM is activated    seconds  auxiliary ALARM is 0     arming  activated CODE    arming disarming    CODE       call for the user function  menu           4 XIGNAddV    0S     ENUEJN Ses     TALVS v9 V9    
35. er is connected plus 8      DLrs keypad connected to the main board RS port  accessible  from the program DLOAD64      DLtl keypad connected to telephone line at the main board   accessible from the program DLOAD64     efn   n  0 63 expander   module connected to the expander bus      sjn   n  1 32 partition     win   n  1 64 zone     Tin   n  1 64 timer     34 Usre s Manual CA 64 SATEL      Tpar partition timer     MnPI control panel main board     Some of event descriptions allow readout of two identifiers  for example  partition  number and zone number  keypad number and user number  etc  To read the  second identifier  press one of keys      change of the parameter displayed for the  currently displayed event only  or     change of the parameter displayed for all  events   Next pressing of the key changes the identifier displayed to the previous  one     Either viewing of all events or viewing of selected events is possible  Also  you may  choose partitions to be viewed  The selection is made for partitions accessible for the  user  who called the function    If the user wants to view selected events  he has to mark at least one event type   otherwise the menu function    Viewing    is not accessible  see Figure 20   Marking of a  partition is not necessary  When the partitions are not marked  the list of events from  all partitions accessible for the user is displayed    Selection of partitions influences the contents of the list displayed when viewing  event types from 
36. essing    causes immediate arming or disarming  if the partition is armed      Typing code and pressing   causes that the list of functions accessible from the  User Menu is displayed  From this menu also the functions of the following type  may be accessed  arming and disarming  if some partitions are armed   When all  partitions are armed  the function Arm will not be accessible     As you can see in the examples described above  the control panel  in an intelligent  way  makes accessible those functions only  which may be executed by a specific  user     All user functions  which are accessible from LCD keypad  are described in  section   Description of User Functions        SELECTION OF FUNCTION    When the control panel accepts the code  the first user function  from all functions  accessible currently  appear in the upper line of the display  You can move through  the list of functions rendered accessible by the control panel by pressing key    and  Y  and select the item in the list  single selection list  by pressing the key   or  gt   If  the selected function requires making further selection  submenu  options   the next  list appears on the display  from which you can select required item in a similar way     Some functions may need selection of few items from the list  multi selection list   To  do that  scroll the list by pressing    and Y key and    mark    all items in the list  which  should be selected  The item is marked by pressing any numeric key  the symb
37. f partitions  This function may be accessible from an  LCD keypad and a partition keypad  When called from an LCD  keypad  the function may arm several partitions  and when called from  a partition keypad  it may arm only this partition  to which the partition  keypad is assigned     Moreover  keeping depressed the key marked 4 displays LCD keypad name  and  depressing two key     and Y  for approximately 40 seconds  causes the keypad  processor to restart and display the keypad software version number and the control  panel software version number     6 User s Manual CA 64 SATEL    LCD KEYPAD    1 2 3 4 5 6 7 8 9 0 11 2 B 4 5 16    CA 64 10 A   lt e gt  2001 Sarel    17 18 9    21223 24 25 2 27 28 29 30 31 32                12  0 7  ZONES 164  36 0     ESENES  ZIEN     JLo JUFJLYJ       Figure 1    An LCD keypad is provided with a large LCD display  2 x 16 characters  with  permanent or temporary backlighting  the latter is activated either by pressing any  key or by violation of any zone  service setting      16 keys  lighted similarly to the keypad screen  are located beneath the display   which are used for       entering the code     moving along menu and selecting appropriate functions from the list     entering data for functions called     Six LEDs are located at the right hand side of the display to indicate current system  status     e ALARM  red      continuous light informs on alarm signalling activation at this  moment  When the LED blinks  it means that  in part
38. f this type       Bistable output     code  which changes the status of the    Bl switch    type outputs     when used  This function may be executed in partitions assigned to a code of this   type    Note  The control panel makes possible to define outputs used for controlling  equipment of different types  for which access must be controlled  Such  control is carried out by means of codes  Monostable output    and     Bistable output     The installer should inform the user about devices  controlled this way       Temporary partition bypassing     code  which de activates partition detectors    for a certain time period  assigned to the code  when the partition is armed  After  this user code type is chosen  when entering or editing   function bypass period    30 Usre s Manual CA 64 SATEL    appears in menu  see Figure 16   where partition bypass time period should be  defined     9  Access to cash point     code  which activates the procedure of access to a cash  point  Cash point is protected 24 hours per day  but activities connected with the  cash point service need detectors to be bypassed  The control panel  automatically restores detector activation after a strictly determined time  service  setting      10 Sentry     global code  which may be used for making rounds by sentries in the  whole system  Typing this code  CODE    into the keypad at the partition  to  which the specific user has access  generates an event    Sentry Round    and   eventually  activates part
39. ge by the user is another  additional partition keypad function  service  setting   User partition change is carried out as follows      Press and keep depressed  for approximately 3 seconds  the key with digit     1     LEDs ALARM and ARMED     red and green     start to flash alternately        Type the old CODE and press    LEDs  ALARM and FAILURE     red and  yellow   start to flash alternately        Type new CODE and press    LEDs stop blinking and the module generates  confirmation signal of function execution      In the following four cases the control panel cannot accept the change of code  it is  signalled with two long beeps      1  the new code is too short or too long  accepteble are codes of lengthfrom 4 to  8 digits    2  the new code is too simple   the function of refusal of simple codes is  activated    3  the new code is identical with a code of another user of the alarm system   Someone s code has been  guessed      4  change of the code has been blocked  because another user  guessed   thecode trying to change his own code  If the function of reminding about the  necessity of code change is activated  each usage of such a  guessed  code  will be signalled with three double beeps  In this event the change of the code  will be possible only by means of the LCD keypad with the requirement of  confirmation of the code change  see  the description of the function  change  own code   by the administrator of the subsystem  It makes impossible to   take over  th
40. h event description in words  zone  module and partition    4 User s Manual CA 64 SATEL    name or name of the user who operates the system  together with accurate time  of the event occurrence    e control and monitoring  up to  8 independent alarm subsystems and  up to  32  partitions armed independently    e control of individual system parts from independent keyboards  maximum 8 LCD  keypads and 64 partition LED keypads     e control and supervision of the system by means of a computer  program  GUARD64     e dynamically changing menu  dependent on access level  to provide access to a  range of user functions     the selection is made by accepting the function at the list  shown in the LCD keypad screen    e key short cuts to facilitate calling frequently used functions     OPERATION OF CONTROL PANEL CA 64    LCD keypads and partition keypads are used for operation of alarm system based  on control panel CA 64  Moreover  the control panel supervises and registers usage  of code locks and proximity card as well as Dallas chip readers  located adjacent  to doors in individual rooms of an object  Partition keypads may be also used as code  locks     Individual control devices are assigned to selected partitions by the installer  LCD  keypads may operate many partitions of different subsystems  Partition LED keypads  operate a single partition only  Individual users may operate the control panel when  they are provided with access to partitions operated by specific keypads  T
41. hat  means  the partitions assigned to the user at the stage of a new user creation or  edition  see Description of User Functions  gt  Users  must correspond to partitions  operated by a keypad  The installer defines the list of partitions operated by individual  LCD keypads     Example  A LCD keypad controls operation of partitions  1 2 3 4 5 and 6  The user  has access to partitions  5 6 7 and 8  It is seen from comparison  that by using this  LCD keypad the user may control operation of partitions 5 and 6     A similar rule applies to partition LED keypads  code locks and proximity card  readers  With keypads  the user may control these partition to which he has access   he may open these doors with code locks and proximity card  or DALLAS chip   readers  for opening of which he has been authorized  The installer defines the list of  users of individual partition keypads  coded locks and proximity card readers   separately for each module      The access to functions controlling the operation of the control panel and more  important information on the system status are protected with a CODE  code      combination of 4 to 8 digits   It is possibile to obtain some information on system and  call some functions without using a code  service setting      by keeping depressed  one of the following keys for a longer time  approximately 3 seconds      Operation of control panel CA 64 5    v        zones status viewing        keypad tampering viewing        expander tampering vie
42. he way of signallisation of individual alarms may be different  and it is defined by the   system installer  It may be an alarm buzzer  information to a monitoring station  visual   alarm  audible alarm and  or  keypad message  telephone message  activation of  other external devices     MESSAGING ON ALARM BY TELEPHONE    The telephone communicator integrated in the control panel CA 64 allows  transmission of information on alarm through the telephone line to any telephone  number  The message transmitted may be adapted to the alarm type  the system    18 User s Manual CA 64 SATEL    installer may install voice synthesizers to allow up to 16 messages to be replayed   The installer defines  who and on which alarm will be informed by the control panel   by programming relevant telephone numbers and defining rules of messaging    Also  the control panel may transmit the information on missing 220 V power supply  in the form of voice message  or pager message   Power supply failure is a serious  danger for the protected object and the alarm system  therefore  this information has  been recognised as equally important as information on alarms     The person  whom the control panel calls  may confirm message receipt  Special  code is used for that  programmed  by the installer  individually for each telephone  number  When the message is not confirmed  the control panel may repeat the  message transmission  number of repetitions is programmed by the installer   The  telephone set m
43. iming to block  it  Additionally  three sequential trials to call programming from outside  block the mechanism of answering to modem signals for 30 minutes        DESCRIPTION OF USER FUNCTIONS    MAIN MENU    The list of functions accessible from LCD keypad is shown in Table 1  First table  column contains names of functions  and specific function properties are given in the  second column  There are functions accessible for the service only  and one function  is accessible for the administrator only  The functions are described by means of  block diagrams  see Figures below   Function names are extended with function  properties  as in Table 1    Some functions are present in the menu alternately  only one of such functions     for  example  Service mode and SM take over     is accessible at the moment  Pairs of  functions of this type are marked with a bold line section  at the left hand side      part  of table frame  function name column     Symbols in column PROPERTIES  table 1      t   function has submenu     multi selection function   XXX   function requires data to be entered  code   name  time    graph   graphical mode of zone  partition and module information display is  accessible   service       function accessible for the service only    master  function accessible for the master  administrator  only    Description of user functions 21    Clear alarm    Clearotheralarms          Abortvoicemessaging      Arm  2 codes   ge      Arming mode    Change own code XXX 
44. ition bypass  Typing of this code into an electric lock  keypad or access trial by means of a proximity card or DALLAS chip generates  the event the    User Access    type  When the sentry is provided with access to  partitions  the partitions may be controlled in a way similar to the control with a  normal code  Typing of the sentry code  the use of a sentry card or DALLAS chip  at the equipment assigned to the partition  where a sentry round is programmed   starts counting down the time to the next sentry round from the beginning  The  installer defines the keypads  with the use of which the sentry should type his  code when performing sentry round in the protected object  and maximum time  period between subsequent sentry rounds  The time period between sentry  rounds is determined for each partition individually  both when the partition is  armed and disarmed     It is also possible to plan the sentry round in one of situations described above  only  for example  when the partition is armed   Missing sentry round generates  the event    alarm     no sentry     which may be signalled at one of control panel  outputs                                                                                                                                                                    Save           Description of user functions 31  code x  Users  select  New user    lect  Edit user se  m gt   User name T  Remove user select   gt   User name        K  type code  User code  XXX  typ
45. itions  accessible for this user  Also  the user may control the status of control panel relay  outputs programmed as    telephone relays     The installer has a possibility to program  up to 16 telephone relays  Also  the installer decides which relays may be controlled  by individual users  To use this function of the control panel  you must have the  telephone set operating in DTMF tone system     Note  Not all cellular telephones allow control in DTMF tone system   How to use this function       Dial the telephone number  line  of the control panel  The way of dialling is  defined by the installer  The control panel may communicate after a defined  number of dialling signals  rings   Dialling may be single or double  When  double dialling is used  wait a defined number of    rings     put the handset off   and then dial the control panel telephone number again  After the number is  dialled the second time  the control panel should answer immediately     Operation of control panel CA 64 19      After the communication is started  the control panel is ready to receive the  user telephone code     three short beeps  prompt        Type code at the telephone set keypad  in the tone system   The control panel  accepts the correct code with series of beeps  four short and a single long one   An incorrect code is followed with two long beeps       Now the control panel operates in the mode of informing on partition status  It  waits for user   s response for 15 seconds and genera
46. itions operated with this  keypad alarm signalling occurred again since the last reset of the alarm memory    e FAILURE  yellow      the LED blinking informs on presence of a technical problem  in the system  Failures  which activate this LED  are described further in this  Manual  see Description of User Functions  gt  Failures     The LED does not light when the LCD keypad operates in partially armed mode   at least one partition accessible for the LCD keypad is armed  or armed mode    all partitions accessible for the LCD keypad are armed   service setting     e ARMED  green    the LED blinks when some partitions are armed and lights  steadily when all partitions operated by the keypad are armed    e SERVICE  green    the LED blinks when the control panel operated in the service  mode  function accessible for the user provided with the service code only      Note  Service mode limits normal operation of the control panel  Alarms from most  of zones  except for zones of the following types  attack  cash point  and  vibrating  and tampering alarms are not signalled  In order to restore the  normal control panel operation mode  just exit the service mode  for the  control panel does not return to its normal operation mode automatically     Operation of control panel CA 64 7    e Zones 1 64  two green LEDs      they are used when viewing and testing status of  zones and    expander    type modules     they indicate which group of zones  or  which expander bus  is currently dis
47. lock it is necessary to close the dependent door and  reenter the code     Blinking of the back lit may substitute the audible signalling  service setting   Beeps  correspond to keypad lighting off pulses  when the lighting is on  or light on pulses   when normally it is off     Also  the partition keypad may indicate alarm occurrence in the partition concerned   service setting      Alarm in the partition     steady sound for total alarm duration       Alarm memory     long sounds every two seconds until alarm is reset  The  sounds are synchronised with ALARM LED flashing  Press any numeric key to  silent the sounds for approximately 40 seconds       Fire alarm     a series of long sounds every second for total alarm duration        Fire alarm memory     short sounds every two seconds until alarm is reset   The sounds are synchronised with ALARM LED blinking  Press any numeric  key for approximately 40 seconds to silent the sounds      Count down of time for entering     short sounds every 3 seconds      Signaling the auto arming delay time countdown  timer controlled partitions     a series of 7 sounds  of diminishing length       Door are open for too long   short beeps repeated with high frequency till  the door are closed  the function of door control is activated      Operation of the system from the partition keypad is very limited  and it relates to the  partition  to which the keypad has been assigned by the installer  There is a  possibility to operate an electromag
48. lose to the card reader and hold it there for  approximately 0 5 sec  The distance between the card and reader  when reading   may be up to 12   14 centimetres  depending on reading head type  DALLAS chip  should be pushed into the head slot to close the zone electric circuit  The control  panel receives the code from the expander operating the reading head  recognises  the user  to whom the card  or chip  is assigned  and operates according to settings  programmed  when the user has authorisation to open the door  to activate the  relay     In the alarm system CA 64  the proximity card reader signals have the following  meaning  DALLAS head may generate identical signals        Meaning of audible signals generated after proximity card readout     single short beep     card code readout     Two short beeps     start of card code writing function  confirmation of first  writing     Two long beeps     control panel have not recognised the card       Three long beeps     card code is recognised  but the user has no access to  the lock  relay control      14 User s Manual CA 64 SATEL       Four short beeps and one long beep     card code accepted  the relay  activation  second correct readout of a new user card      Five short beeps     dependent door open  relay has not been activated        Short beeps  without time limitation      door opened for a too long period       Meaning of visual signals emitted during armed status and after proximity card  code readout       LED blink
49. meric LCD keypad  Each function is  described in detail and shown in a block diagram     The text in this Manual contains some technical terms  please  use APPENDIX C at  the end of Manual for explanation     This Manual refers to the control panel program  version 1 03 12  and the  DLOAD64 installers program  version 1 03 15  up to date on the day of  preparation hereof     2 User s Manual CA 64 SATEL                            CONTENTS   INTRODUEFION G iz ORO GOA E AA OOO AO 3  OPERATION OF CONTROL PANEL CA 64             0200  2002000o0000000o0000ooeooooaooe ow owao wo ow owao wo oa wdowa ow owa owo od owao wod o0a0 000 4  BASIC INFORMATION   ua dias 4  LEDIKEY PAD co aida 6  THE USE OF LED KEYPAD oa 7  PARTITION KEY PAD yw cease need ices teeta tence hea ost 10  CODE LOCK a eee ee 12  PROXIMITY CARD AND DALLAS CHIP READER cooooococoonconoononnonncononnnonconnonnonconncononnnonnon rra nono rra naar reinos 13  CODES AND USERS hepe EE A r TE E dos 14  SYSTEM ARMING is 15  ALARMS dd et bes ab 17  MESSAGING ON ALARM BY TELEPHONE           cccccessessesseseeseeseesecseeseceseneeseceaecacsaecaesaecaeeecaaeesesaeenenaeenees 17  ANSWERING  PHONE CALLS gee a W A ADR AE ds 18  OTHER FUNCTIONS USING TELEPHONE LINE                        ee  eee eee eee aaa aaa aaa area oaza wazna ea acaae 19  DESCRIPTION OF USER FUNCTIONS              2 02 0 0 0000 00000o0o0eowooeoweoeowao wo oe ow ao wo oe ow ao wo oe owad wo oe owa owsa wan wood owa0 wwo 20  MAIN MENU tei O EEE O GS   A ORC MAG Ao 
50. nders  LED marked 33 64 will light   Symbols displayed at the keypad  screen are as follows     correct status    e  contact violated    X    expander replaced  verification error       _   expander is missing     38 Usre s Manual CA 64 SATEL      Supply voltages   checking power supply voltage level for individual expanders   The display shows the expander name and approximate power supply voltage  level for this expander        Zone Test   the function allows to check which of control panel zones used are  violated when the test is carried out  After the function is called  the display shows  the text    New        press key   or  gt  to start the function of registration of zone  violations  Subsequent calling of this function by the same user makes accessible  the function    Test result viewing      press key   or  gt  to open the list containing the  number of zone  zone name and information on whether it was violated at least  once during the time the test was carried out  Next pressing of the key  gt  changes  the descriptive mode of the test result display to the graphical mode  In the latter  mode  the following information is displayed      zone was not violated       zone was violated    The duration of the test is unlimited  Test results are accessible for the user  who  started the function  The user is allowed to test the zones in these partitions  to  which he has access     Note  Calling the new test function by the user cancels the test previously  started b
51. ne call     OTHER FUNCTIONS USING TELEPHONE LINE    If the alarm system uses functions of the control panel telephone communicator  the  line from the local exchange to the object is connected directly to the control panel   and all telephone sets are located downstream the control panel  Therefore  no  signals are heard in telephone sets  when the control panel uses the telephone line   This situation may occur frequently in multi partition system  where monitoring is  activated  Moreover  the control panel will disconnect the telephone conversation   when taking over the telephone line in order to transmit an information on a new  event  It should be said that control panel phone calls do not last for a long time  from  several to tens seconds  depending on the selected format data transmission      Another function  where the control panel occupies the telephone line  is  programming by the telephone     downloading      This function may be initiated by the  service  The telephone line may be occupied for a long time  when data are  transmitted  Even if the programming is initiated by the user  the service may hold  communication with the control panel for cost saving reasons  and then restore it  without engaging the user     20 User s Manual CA 64 SATEL    Note  Access to the control panel in programming mode by telephone is protected  with ten byte code  more than 1 2x10  combinations   This is a very good  protection against hacking to the control panel by telephone a
52. netic door lock from the partition keypad by  means of the user   s code  Several partition keypads may be assigned to a single  partition     Functions accessible from the keypad are as follows      gt  CODE   arming and disarming of partition and alarm reset    gt  CODE x electromagnetic door lock opening     Similarly to the LCD keypad  the user  who wants to start functions mentioned above   need to have access to the partition concerned and proper authorisation  Besides  he  need to be authorised to use the partition keypad concerned  these rights are  assigned by the administrator with in the GUARD64 program  or the installer  service   in the DLOAD64 program     When the erratic code is typed three times  the alarm may be activated  service  setting      Other functions accessible from the partition keypad  without code entering  are as  follows      gt  04   quick partition arming    and functions of calling special alarms   w      panic alarm     0 auxiliary alarm  calling for medical aid    7 x fire alarm     The last three functions are started by longer keeping depressed  for approximately 3  seconds  the key described above     12 User s Manual CA 64 SATEL    Note  When arming is on for the partition  and the partition keypad also controls  the electromagnetic door lock  typing  CODE   causes disarming and door  opening     if the partition is not bypassed temporarily  However  If the user  has no authorisation for disarming  the door remains closed     Code chan
53. not know the system very well  Also  taking into account the safety of the object  it is  not recommended that most of users have access to all control panel functions     The system incorporates the hierarchy system for access to the control panel  functions and partitions defined for the object by the installer     Generally  typing at the keyboard      gt  CODE   gives access to functions of arming disarming type    gt  CODE x gives access to all functions in the User Menu  to which the  user is authorised    Note    When an erratic code  not recognised by the control panel  is typed three  times  the alarm will be activated  service setting      The list of the control panel functions for user access is formed in a dynamical way   The contents of the list depends on system parameters  code type  user authorisation  and alarm system status and situation     Example  When you type your code and press    the control panel makes accessible  functions of partition arming  provided there are no partitions  operated from the  LCD keypad  already armed  or disarming  if any of partitions is armed   In the  event of alarm occurrance in the system  the control panel may cancel this alarm  and make accessible the function of partition disarming  if the user has  authorisation to do that   When the function of messaging by telephone is  activated     function Cancel messaging by telephone may appear in menu  When  the user has access to a single partition only  typing the code and pr
54. ntrol panel in determination  which  partitions may be armed at the moment  is its great advantage        BASIC FUNCTIONS OF THE CONTROL PANEL     e signalling burglary  attack  fire  technical and auxiliary alarms   e monitoring     communication with telephone monitoring stations  real time sending  detailed information on selected events in the protected object    e messaging on alarm by telephone     either with the use of a vocal message or toa  pager   e answering phone calls  this function is protected with a separate code  that makes  possible     to inform the user on a system status     to control some of the control panel functions via telephone  these functions  are programmed by the service   e real time printout of information on all or selected events occurred in the alarm  system   e supervision of access to rooms through doors provided with electromagnetic  locks   e monitoring the correctness of operation of individual alarm system components   power supplies  batteries  wiring      CONTROL PANEL USAGE PROPERTIES     e operation by means of keypads provided with LCD text display  2x16 characters   to facilitate the use of the system    e descriptions of zones and partitions defined by the installer make easy to find the  alarm source    e visible date and time of the system clock allow controlling the correctness of  functions that depend on the real time    e accessible are  viewing the alarm memory and failure memory  or detailed  memory of all events  wit
55. o bypassed zones   The function is used in case of a detector failure or its incorrect operation  It gives the  possibility to arm the system ignoring the bypassed zones  The bypass entered with  this function is cancelled after disarming  Also  zone bypass may be de activated with  the use of this function  Proceed in a way reverse to bypassing of zones     remove  marking of zones marked  The installer defines zones  which cannot be bypassed  with this function     mark selected  code x  P  Zone bypasses Zone bypass  n   QU   gt  K  Zone name  n     number of a zone in the system                                         Figure 17    SET TIME    The function makes possible to enter the actual time and date to the alarm system   This data are entered in the following format     time   HH mm SS  hour minute secona     date   DD MM YYYY  day month year   New data are entered by typing the correct digit at the place of the cursor flashing   After entering the digit  the flashing indicator moves to the next position on the right   Also  it may be moved with the use of keys     and        type time  code             Set time  gt  Set time  XXX  HH mm SS                                 type date  Set date  XXX  gt  gt  K  DD MM YYYY                            Figure 18    Description of user functions 33    FAILURES    The function makes possible to scroll the list of failures occurred in the alarm system   It is accessible only when FAILURE LED flashes at the LCD keypad and partiti
56. o edit the users they  entered  This possibility is convenient when the code is lost  The supervisor of the  user concerned may enter a new code and make controlling the system available for  him  of course  within the range limited by his authorisation     The control panel assigns numbers to the users to identify them in the system  This  number is used in messages transmitted to the monitoring station and in event  descriptions  see  Description of User functions     Event history      SYSTEM ARMING       Armed    is the basic status  for which the control panel was designed  In this mode   the control panel detectors monitor the protected object  and any violation of the  protected partition is signalled by the control panel with all means accessible   programmed by the installer   Control panel CA 64 enables individual control of  armed status in each partition  A single partition  several partitions and all partitions  may be in armed status  Each partition may be disarmed individually  by means of  partition keypad  LCD keypad  or totally  LCD keypad      16 User s Manual CA 64 SATEL    Typing the following at the keypad is a normal way of arming      gt  CODE   partition keypad arms a single partition  and keypad gives the  possibility to arm all  or selected  partitions accessible     gt  04 quick arming     the partition keypad arms a single partition  and  keypad arms partitions programmed by the installer  no selection  possible      If one of partitions accessibl
57. ol  appears in the upper display corner next to the text  Press the numeric key again to  cancel marking    By scrolling the list upward or downwards  list contents is displayed in a cyclic way    you can see all list items and check marking  Pressing the key   or  gt  accepts the  selection  execution of function may be confirmed with beeping   and the control    Operation of control panel CA 64 9    panel returns to previously displayed menu or displays the adequate message and  returns to the basic status  waiting for code   Then  current date and time is  displayed  Date and time display format is defined by the installer  service setting      There is the control panel setting option  which activates the procedure of double  acceptance of some user functions  After pressing the key   or  gt   normal way of  selection of function   the prompt appears on the screen asking to confirm the  function  together with information  1   Yes  Press the key with digit 1 to confirm this  function  This procedure protects against accidental double pressing the key    or  gt    and execution of function  which should not be executed  The description of user  functions in this Manual relates to situation when this option is switched off     If you want to abandon the selection of function after opening the User Menu  press  key    In the event no keypad button is pressed  within 2 minutes  after menu  opening  the control panel automatically closes this menu and returns to its basic  sta
58. on  keypads  You can find the list of possible failure messages at the end of this Manual   APPENDIX A     The name of element concerned  entered by the installer  appears in messages  related to zones  expanders and keypads  in bottom line of the display  No additional  message is displayed at the end of this function     NOTE  Inform the service person immediately in the event of any failure in the  system  and remove the cause of the failure alarm   press   to end  code   Failures           Message t  Name                Figure 19    EVENTS    The function makes possible to scroll the list of events stored in the control panel  memory  The events are given in the sequence order of their occurrence  The event  description contains data displayed in the following format  see Figure 20      date   DD MM  day month    time   HH mm  hour minute    identifier   xxxx  four characters   IDEN  which identifies the number    of zone  partition  module  user operating the system   special symbol   Event name   text in second display line     Description of meaning of identifiers       Ser  user     service code     Adm n     n  1 8 user     subsystem administrator code     ujn   n  1 192 ordinary user of the system     mjn   n  0 15 keypad     module connected to the keypad bus or virtual  keypad accessible from the program GUARD64   0 7 nos of keypads in the system   8 15 nos of keypads accessible from the program GUARD64   defined as follows  no  of keypad to which the user  comput
59. on  mode  the control panel programming is possible with the use of program DLOAD64  via RS port  at the main board  and via the telephone line   The control panel remains  in the service mode until exiting it with function    End of SM  service mode      entry in  the list of service functions   or until the time limit given by the administrator elapses     40 Usre s Manual CA 64 SATEL    The function is accessible after unlocking service access by the administrator and  entering the service code     SM TAKE OVER    The function makes possible to switch over the operation control of the control panel  being in the service mode to the keypad other than the one  from which the service  mode has been called  The function is accessible for service only  It is intended for  use in large objects  where several keypads are installed     the function facilitates  installer work        DOWNLOADING    The function  which starts communication with the service computer  It allows  installer to program the alarm system by means of the computer and the service  program DLOAD64  It is possible to start direct communication via RS port  as well  as indirect communication via the telephone line  with the use of either external or  internal modem   To start a telephone call it is necessary to program the service  computer telephone number                                         select   code x          Downloading Start DWNL RS service K  Finish DWNL RS _  service  Start DWNL TEL          Fig
60. oor opening    gt  CODE x door locking   When  gt  erratic code is typed three times  the alarm may be activated  service  setting      It is possible to call special alarms using a code lock keypad  These three functions  are called by longer keeping depressed  for approximately 3 seconds  the key       A panic alarm     0 auxiliary alarm  calling for medical aid    7   x fire alarm     Confirmation of the function called by the control panel  with sound or blinking  is  identical as for partition keypad     PROXIMITY CARD AND DALLAS CHIP READER    Proximity card and DALLAS chip readers have the same role to play in the system as  code locks  Proximity card readers are provided with two colour LED and buzzer for  communication of the control panel with the user  DALLAS chip heads are not  provided with any signalling of this type  but the installer has a possibility to provide  such an external signalling     Each alarm system CA 64 user  administrator  sentry  ordinary user  may be  assigned with one proximity card and or DALLAS chip at the stage of user creation or  edition  Also  it is possible to remove the previously assigned card  chip  to a user  from the control panel memory  In order to provide a new user with a card  chip  with  a code already known to the control panel  first remove this card  chip  from memory   see  USER MANUAL  CA 64  gt  Description of user functions  gt  Users   and then  assign it to another user     Use the card as follows  bring the card c
61. part II  below      44 User s Manual CA 64 SATEL          Function Activate selected marked     or   Calling the function        12 3 4 5 6 78 9 01 2 B 4 5           Miro FET     or    Scroll the list with partition names  Press one     Storeroom  of these keys so many times as you need to  display the name of the partition required   partition 2     Book keeping                  17 1819    2122324 52  2 28 2 30 31    CONTROL PANEL 12 07  64   zones          p    After the function is called  the control panel displays  partition names  factory set or entered by the installer    which the user may arm  Press key   to move to the  graphical mode of partition selection         12 3 4 5 6 78 9 011 12 B 4 5  3 Mark the partition selected for arming  l mark    at the right hand side of the display  using any  p  What to SLNN  numeric key  BOOk keeping                   17 1819 02122324 25 2 2 22 2 30 31  CONTROL PANEL 12 0 gt         You may select for arming  mark  any number of  partitions accessible to you  Also  you may cancel  marking for partitions selected earlier          End of selection and arming of all marked ae a      partitions           System armed                   7189021234 5627 728230 31    CONTROL PANEL     1 32    Q  j  ZONES        m    When this message appears  counting down time for  leaving is started in the armed partitions     GRAPHICAL MODE    There are two ways of selecting the partitions for arming     using names     as described above     using pa
62. played on the LCD keypad screen  see  Description of User Functions  gt  Tests      In addition to visual signals  the LCD keypad may generate audible information   service setting   The following signals  specific to some situations  may be heard  when using the keys       One long beep   refusal of arming   the zone  which shouldn t be violated at the  time of arming  is violated  option    PRIORITY    The refusal includes all zones  selected for arming      Two long beeps     the control panel did not recognise the code  function is not  accessible  erratic data  confirmation of abandoning the selected function  after  pressing   on the keypad keyboard   the key pressed is not active       Three long beeps     the code is recognised  but the called function is not  accessible  for example  temporary partition bypass is activated or the user has  no access to partitions operated from the keypad  the zone  which should not  be violated when being armed  is violated     refusal of arming       Two short beeps     selection accepted     entering more detailed menu level      Three short beeps     confirmation of arming or disarming      Four short beeps and one long beep     acceptance of execution of the selected  function      Three pairs of short beeps     it is necessary to change the code  for example   another user  when changing his code  has given an identical combination of  digits as the combination in the code of the user  the code validity is expiring      Moreover
63. ple   NOTE  When all partitions accessible for you are armed  the function Arm will not be shown in the menu  on  the keypad display      If some partitions in the subsystem are already armed  the following texts will appear on the display     12 3 4 5 6 78 9 0 L 2B 4 5   ALARI       gt Disarm F  Arm mo O  SERWCE O   17 1819 0212 23 24 25 2 27 22 2 30 31  CONTROL PANEL 12 07                   CA  ZONES       In this situation  perform as follows        Indication of the function Arm    Hor    Select the function marked with arrow      Whot to arm   moving to the stage of partition selection tor        storeroom  arming  as described in details in the first part  of this example                    If we assume  in this example  that the partition 2  Book keeping  has been already armed  after  calling the function Arm again and entering the graphical mode of partition selection the following  display will be shown                    Now  partitions 1  3 and 4 may be armed     46    Example 2     NOTE     11114    NOTE     or      or       User s Manual CA 64 SATEL    DISARMING  part I   Partition No  2 named    Book keeping     belonging to the subsystem 1  user     the  subsystem master     The function is available only when at least one of partitions accessible for the user is armed           Enter the user code  factory set administrator  code for the subsystem 1     Also  you can enter the code of any user  who  has access to partition 2 and authorisation for  disarm     
64. r disarming  mark  any number of  partitions accessible for you  Also  you may remove  marking for partitions selected earlier     12 3 4 5 6 7 8 9 0 I 2B 4 5    End of selection and disarming iof all partitions  marked                    Appendices    1111     Hor       NOTE     ARMING  part Il     47      with the use of all user function menus accessible     Type code     calling the user function menu     Select the function marked with arrow      moving to the stage of partition selection for  disarming  as described in detail in the first  part of this example            12 3 4 5 6 778 9 0 1 2B 4 SE    _  gt Disarm  Change ovn code                17 1819    2122324 52  2 28 2 30 31    CONTROL PANEL     1 32  0   ZONES    a          123456 78 9MDURBHM 5    What to disarm   Workrocm il                17 1819 0212 23 24 2 2 27 28 229 30 31  CONTROL PANEL 12 07   ZONES 164  34 03    If only some partitions in the subsystem are armed  the following texts appear at the display            12 3 4 5 6 78 9 01 2 B 4 B    _  gt Disarm  Arm                17 1819    2122324 52  2 28 2 30 31    CONTROL PANEL 132 0     64   zones       p    Performance in this situation should be identical as  when all partitions are armed     If we assume data from the example presented earlier  the following picture may be shown at the  keypad screen being in the graphical mode of partition selection            12 3 4 5 6 78 9 01 2 B 4 SE                17 1819    2122324 52  2 28 2 39 31    CONTRO
65. rtition numbers     in the graphical mode described below     This is the mode for the user who knows numbers of partitions in the alarm system  or the user   who wants to check quickly how many of zones are not armed yet         12 3 4 5 6 78 9 01 2 B 4 SE                TS These keys are used to select partitions in  the graphical mode        These keys are used to select partitions in    17 1819 2222324 52  27 28 2 39 31    CONTROL PANEL     1 32  0   ZONES    the basic mode  using partition names    It is possible to switch over between modes  as many times as necessary           p       Dots next to numbers 1 32 indicate partitions  which  may be armed  1  2  3 and 4   The cursor under a dot  allows to select the partition  which may be marked for  arming     Appendices 45        12 3 4 5 6 78 9 0 L RBH 5   Move cursor under the 2    partition field    3 Mark the partition for arming with any numeric  key                 17 1819 22223 4 52  2 28 29 30 31    CONTROL PANEL 12 0 gt   64   zones             p    Pressing the key   after selection of partition makes  it armed  independently of the display mode     ARMING  part Il     with the use of all user function menus accessible                    12 3 4 5 6 78 9 0 L RBH 5  1111  Type code     calling the user function menu     Hor    Select the function marked with arrow     Change own codel a    o  moving to the stage of partition selection for E NZ  arming as described in details in the first part ire e   of this exam
66. s red in a uniform way     missing communication with control panel   this situation may occur when the special system initialisation program  STARTER is running in the control panel  the reader module has not been  identified or the cable connecting the module to the control panel is damaged        LED lights red steadily     module is correct  lock operation  relay control  is  possible       LED changes colour from red to green once a second   2 single short changes     waiting for first card reading      double short changes     waiting for second reading of a new card       The installer may activate the option of confirming with a LED the messages sent  from the control panel to the user  In this case  after the card is read  the change  of LED colour from red to green goes on in accordance with audible signalling  described above     CODES AND USERS    The functions of control panel operation is possible after entering a proper code and  pressing key   or    Three basic code types are used     1  Service code     this code identifies the user with special rights  he controls all  partitions  he may open all doors controlled by the control panel  he has access to  most of control panel functions  except for the    Service access    and    Users     functions     see Description of User Functions   he may enter and delete  subsystem administrators  Factory programmed service code   12345     2  Administrator  supervisor  code     this code identifies the user with highes
67. stalled by the installer  The control panel may perform its functions in many ways   which are defined when installing the system and its software  Due to the above  the  installer should give you more detailed information regarding the operation of the  alarm system and procedures of its using     All situations  where the way of the control panel operation depends on previous  installer decisions  made at the time of programming   are additionally marked with  text in brackets   service setting   following the description of situation   The term     service    used in this Manual relates to the user who maintains and takes care about  the alarm system and uses the service code  see page 12   It may be the installer   maintenance person  the employee caring for protection of the object  etc     ABOUT THIS MANUAL    This Manual describes the basic operation of modules used for controlling the system  operation  as well as the control panel functions    The first part of this Manual  titled    Operation of Control Panel CA 64    contains  descriptions of modules used for controlling the operation of the control panel and  their way of use  Also some functions related to the alarm system operation are  described here  Furthermore included are the basic information on system  functioning and use of the telephone line by the control panel    The second part of this Manual  titled    Description of user functions    contains full  specification of functions accessible from alphanu
68. t  authorisation for subsystem  The administrator has access to all partitions within  his subsystem  There is a function which unlocks the service access  see  Description of User Functions     Service access level   This function is always  accessible for the administrator and not for the service  Factory programmed  administrator code for a first subsystem  1111     Other administrator rights may be limited by the service  installer   If few  subsystems are defined in the system  each subsystem has its own administrator  code  This user has the right to enter new users into the system    3  User code     the remaining codes entered to the system by administrators or  users  with rights to edit the user   These are the codes for everyday operation of  the system  192 user codes may be entered in the CA 64 control panel     Operation of control panel CA 64 15    Notes       Service code is rejected by the control panel  when service access is locked  The  administrator may unlock the service access to the alarm system by using the  function    Service access     see  Description of the User functions        If there is no administrator code in the system  all administrators are removed    service access to the system is unlimited       It is recommended not to use the administrator code everyday  unauthorised  persons may peep the code   The administrator should enter an ordinary user  code  with    strategic    functions blocked  and he should use it in everyday work   Prot
69. t of possible event messages  Event name  is at the end of this  Manual  in APPENDIX B     RESET ZONES       The function forces short voltage loss at detector power supply outputs with  activation memory  for example  fire detectors   This operation clears detector  memories    If few identical detectors are connected to a single output  the activation memory  allows finding the detector which triggered the alarm     code x           gt  Reset zones _     P _K      Figure 21       CHANGE OPTIONS    This function controls the    GONG    type signalling and allows setting partition user  timer which automatically armes and disarms     Gong in keypad     signals the violation of any zone  detector  selected by the  installer  Few zones may be selected  and they will activate signalling in the keypad   The gong signal in each keypad may be activated from different zones  The function  makes possible to block and unblock the signalling mentioned above in the keypad   in which it was called     Gong from output     there is a possibility to configure the output intended for  signalling the violation of selected zones  This output generates signals a control  panel zone violation with the marked option    Gong control     It is possible to block or  unblock activation of such signals for individual partition outputs separately     Partition user timer  see section  SYSTEM ARMED  allows automatic zone arming  and disarming    1  To enable timer operation  mark the parameter    Activ
70. tes one short beep every  two seconds  Now It is required to enter the partition number at the telephone  set keypad  two digits     for example  01  05  12  25   If the user does not  respond within this time  the control panel will ring off   After the partition number is entered  the control panel generates the message   Three short beeps inform that the partition is disarmed and four short and one  long beeps mean that the partition is armed       Alarm memory is an additional information given by the control panel  If an  alarm occurred in the partition  the control panel generates series of double  beeps     first is lower and second is higher     following the information on the  partition status  Where no alarm occurred  the control panel generates single  short beep every two seconds     In order to move to the control mode of the telephone relays status  press 2 and    at the telephone set keypad       Now the control panel waits for the relay number  two digits   To trigger the  relay status to the reverse one  type the relay number at the telephone set  keypad  Two short beeps mean that the relay has been switched off and four  short beeps and one long beep mean that the relay has been switched on   Each time you type the relay number  you change its status to the reverse one     You may move back to the partition status indication mode by pressing keys 1 and    one after one     When you press keys 0 and   one by one  you exit the function and terminates the  pho
71. the user              select  code   Arm all mark selected   K    Arm selected What to arm             partition name graph          code      gt  Arm             Figure 7    ARM  2 CODES     The function arms special partitions  Two different codes must be used to arm them   The presence of such partitions is declared  programmed  by the installer  The  second code must be entered within 40 seconds after entering the first one  after that  time the control panel returns to the basic menu     select partition  code        Arm  2 codes   _  Partition name g                                type code    Enter the XXX Ls k    second code                Figure 8    DISARM  2 CODES     The function disarms in special partitions  Two different codes must be used to  disarm them  The presence of such partitions is declared  programmed  by the  installer  The second code must be entered within 40 seconds after entering the first  one  after that time the control panel returns to the basic menu     select partition  code       gt   Disarm  2 codes   gt   Partition name g    DEFER AUTO ARM    The function puts off  delays  the arming of a timer controlled partition  auto arming    It is intended for programming the value of time interval by which the moment of  automatic arming of a partition is to be delayed  The maximum postponement time  value is 4 hours  33 minutes and 3 seconds  Entering a higher value will set the  maximum permissible value  while entering the zeros alone will canc
72. tus     GRAPHICAL MODE    Partition selection functions allow also another way of multiple selection from the list   for example  selection of partitions for arming   It is called a graphical mode  When  you have already entered the selection list  press key  gt  or    to enter this mode   Dots under the number of each accessible partition  numbers 1   32 around the  display  appear on the keypad screen  The dash under the dot  cursor  indicates  which item may be marked  Use key  gt  and    to move the cursor to the item  required  Pressing any numeric key causes the symbol W to appear at the item  selected  Press the numeric key again to cancel marking  Press key f or 4 to  restore the previous way of display  with name      ALARM SOURCE NAME READING    The installer may also render accessible the function of displaying the name of the  alarm source at the LCD keypad screen  without necessity of entering the code  In  such an event  the partition or zone name is displayed at the keypad screen  when  an alarm occurs  When there are few alarm causes  you may scroll zone names  for  which alarm occurred  and names of partitions  where the alarm is  or has been   signalled  Arrow keys     and    allow viewing partition names  if an alarm occurred  for few partitions   and keys ft and Y allow viewing zone names  for which an alarm  occurred  These names  entered initially by the installer  are displayed in a cyclic way  in the lower display line  and they are shown in numeric or
73. type for a partition  this timer may  be programmed in daily or weekly cycle  see  Description of User functions  gt   Change of option      e partition arming control by means of a special zone programmed  by the installer   as arming control zone  In practice  it may be a mechanical switch  key switch   pushbutton  radio switch  Also  such a zone may be controlled via telephone      with the use of DTMF system  see  Answering phone call      ALARMS    The system may signal alarms as the response for various situations occurred in the  protected object  Basic control panel alarms are as follows     e Burglary alarm     activated when the zone is violated in the partition where arming  is on  The violation of the    delayed zone    starts to count down the delay time  after  which alarm is activated if the partition will not be disarmed     e Fire alarm     activated by fire detectors  from keypad or in another way  for  example  pressing the pushbutton      e Tampering alarm     activated by violation of any anti tampering contacts in the  alarm system  located in detector and module casings   damage to cable s   etc     e Attack alarm     activated from keypad or in another way defined by the installer   for example   pushbutton      e Auxiliary alarm     activated from keypad  for example  call for medical aid  or in  another way defined by the installer  for example   remote controller or  pushbutton     e Technical alarm     activated by various specialist detectors    T
74. u may    switch over between Z0N    sets as many times  as needed     End of function                    17 1819 2222324 52  2 28 2 30 31    CONTROL PANEL     1 32    Q  j  ZONES 14    3044         The LED 33 64 being ON indicates the set of 33 64  zones  the status of which is shown on the display  Add  32 to the number next to the zone symbol  numbers  around the display  to obtain the zone number     Functions of LCD keypad keys and LEDs  see pages 4     7 for detailed description      1 to 6   keep pressed for 3 seconds LCD DISPLAY  date ALARM FAILURE     signals that the technical  to get access to the viewing and time   steady light     alarm in the problem has been detected in the system   functions  operated partition   check by pressing the key   for3      blinking light     alarm seconds   memory for the partition        1   zone status viewing  2   keypad tampers viewing  3   expander tampers viewing    ARMED       steady light     all partitions operated by  the keypad are armed      blinking light     some zones are armed     4   partition armed status viewing   5   alarm memory contents viewing   6   failure memory contents viewing   see  descriptions of functions    CA 64  TESTS and EVEN HISTORY    VIEWING  NS e ai AGE    N  NI 17 18 19 0 212 23 4 25   27 28 2 30 31 32   gt  1 32     zones 1 32 or the first  n Na o z  expander bus  7  when pressed for 3 seconds  a x  message on currently detected  failure is displayed 33 64     zones 33 64 or the  second expand
75. ure 25    Description of user functions 41    SUMMARY    The alarm control panel is one of components of an alarm system  it works  surrounded by many pieces of equipment  and performance of each system  component decides on the performance of the entire system  Therefore  we  recommend testing the operation of the entire system and each system component  on the regular basis  It is a good practice to order periodic inspections from the  system installer     The installer should train system users on the following issues     ways of signalling and types of alarms    action procedures duringf various types of alarm    correct work of the control panel with a monitoring station    operation of modules  which control the operation of the control panel    operation of additional devices controlled by the control panel  if such equipment  is installed       actions in case of failures in the system        o o    Pay particular attention to the number of messages transmitted to the monitoring  station  Large number of occurrences  on which the monitoring station is informed by  the control panel  loads the telephone line excessively  and it may make it difficult to  send important information concerning the safety of object and people being inside     Remember that operative alarm system is not the full protection against  burglary  attack or fire  The system only reduces the risk of such occurences  performing the functions of signalling and informing     42    APPENDIX C    User 
76. ust be set to the DTMF tone dialling     If the code is not correct  the control panel signals that with two long beeps  Correct  code is confirmed by four short and one long beeps     When  instead of sounds described above  you hear a single short beep every three  seconds  the code is correct  but you must wait  because there are several messages  about different alarms     If you make a mistake when entering the code  press any numeric key to supplement  the code to four digits  then the control panel signals erratic code   and next enter the  correct code     Note  The control panel analyses telephone signals in order to recognise whether  the phone call is answered  Therefore  it may occur that you will hear the  message after few seconds  up to 4 seconds  from picking the earphone   This effect is not an error     it results from phone call confirmation signal   When you say  halo       to the earphone  the message will be communicated  immediately     ANSWERING PHONE CALLS    The control panel CA 64 is able to answer phone calls and communicate information  on the system status  Also  you may call control functions with the use of telephone   Each ordinary user may  at the stage of user entering or edition  be assigned with a  telephone code  do not mix this code with the code for confirmation of receipt of a  telephone message on alarm   The control panel recognises the system user with  this code and passes an information on partition status  armed  alarms  for part
77. wing        partitions status viewing        alarm memory viewing        failure memory viewing        current failure viewing        switching on   off gong signal in LCD keypad       auxiliary alarm  for example  calling medical aid        fire alarm        attack alarm     4  tHXOONDOAARWNH    Functions of keys from 1 to 8 are accessible from LCD keypad only  and other  functions may be accessible  service setting  from each keypad installed in the  system  LCD keypad  partition keypad  code lock   The functions called this way  provide information on all partitions operated with specific LCD keypads  Also  they  are accessible via the User Menu  see  Description of User Functions     Tests  Event  History  Failures  Change of Option   however  when called via the User Menu they  provide the information on partitions accessible for the individual user  who called  that function  only     It is recommended that this way of calling functions be accessible in LCD keypads  fully protected against access of unauthorised persons     An    attack alarm     called by    may be signalled externally  in a similar way to an  alarm of    burglary    type  buzzers  lights   it also may be arranged not to activate any  signalling and remain as a    silent alarm PANIC     service setting      Also  the installer may render accessible the function of quick arming of certain  partitions  so called QUICK ARM  to be called by pressing two keys  O and   in  sequence      gt  04 quick arming o
78. y another user        Manual test transmission   the function generates the event  which starts the  procedure of message transmission to the monitoring station        Monitoring station test  1A 1B 2A 2B    the function makes possible to carry out  the test transmission to the monitoring station  to each accessible telephone  number separately   The test transmission is carried out with tracing the data  transmission process at the same time  The messages at the keypad display  inform on current activity  In practice  the function is used by the installer when  starting communication with a monitoring station        Viewing masters   the function is accessible for the administrator only  It allows  checking  for which subsystems the administrators are created  It allows to control  the number of users  who are able to give permission to access the system in the  service mode        Control panel version   the function shows the current control panel software  version number at the keypad screen     No additional message is displayed at the time of exiting the function     Description of user functions 39    select one of these functions   press   to exit                                  code k P Tests    Arming status graph  Zone status t graph  LCD keypad status0 graph service  Expander status t graph service  Supply voltage  power       service  Zone test   graph       Manual test transmiss   1A station test  1B station test  2A station test  2B station test  Viewing the m
    