FMUX03 E1 manual
Contents
1. Application 2 CTC Union FMUX03 1 3 FMUX03 Technical Specifications Interface gt gt gt gt gt Channel Capacity 4 8 16 channels Bit Rate 2 048Mbps 50ppm Line Code HDB3 AMI Impedance Balanced 1200 Unbalanced 750 Electrical Interface Conform with international standards ITU T G703 Jitter Tolerance Conform with international standards ITU T G 823 Jitter Transfer Conform with international standards ITU T G 742 Test Load Impedance Balanced 120 5 resistive or Unbalanced 75 5 resistive Pulse Shape Conform with ITU T G 703 standards Nominal peak voltage of mark pulse 3 0 Volts Nominal voltage of a space no pulse 0 3 Volts Ratio of the amplitudes of positive and negative pulses at the nominal half amplitude 0 95 1 05 Ratio of the widths of positive and negative pulses at the nominal half amplitude 0 95 1 05 Oo Nominal Pulse Width 244ns The digital signal presented at the input port shall be as defined above but modified by the characteristic of the interconnecting pair The attenuation of this pair shall be assumed to follow a yf law and the loss at the frequency of 1024 kHz shall be in the range of 0 to 6 dB The minimum values for Return Loss is listed below Frequency KHz Min Return Loss Value dB 51 102 12 102 2048 18 2048 3072 14 Jitter generation The jitter of the E1
2. 10 4 RX_T4 R3 11 Ch3 Rx pair 54 RX_T3 OH TX R3 OLI TX T3 Ch3 Tx pair DB25 female A 2 Pin Assignment for Tributary E1 pad Ch2 Ch GND CTC Union FMUX03 A 3 Alarm Alarm Status LED sign MAJ MIN Single OE OLOSW OLOS1 OLOSP OLOS2 Dual OE OLOSW OLOS1 OLOSP OLOS2 OLOSW amp OLOSP OLOS1 OLOS2 Dual Power PWRFI PWRF2 ELOSI ELOS2 ELOS3 ELOS4 ELOS EAISI EAIS2 EAIS3 EAIS4 OAIS AIS ELOFI ELOF2 ELOF3 ELOF4 OLOF LOC_8M LOC_2M LOC 8RM SYS ERDI ORDI RDI CTC Union FMUX03 TC Fiber Optical union Multiplexer Series CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhouzi Street Neihu Taipei Taiwan Phone 886 2 2659 1021 886 2 2799 1355 E mail info ctcu com http www ctcu com
3. CV Setting 4 2 Line ES 24 fees b 3 Path CV 15 min gt 4 Path ES 1 hr 2Op cd 5 Path SEC 24 hrs 6 Path UAS 8 Agent Network 1 Device IP cur 792 108 10 244 Configuration 2 Host IP cur 792 108 103 3 Net Mask 255 255 255 0 4 Gateway cur 792 768 70 7 5 cur 00 34 67 9a cd ff 9 System Information 1 Time 00 00 00 00 00 2001 gt 5 Write Community 6 Read Community 13 Chapter 4 Operating and Setup Instructions FMUX03 provides easy to use LCD control for easy configuration maintenance and testing Button functions are as follows gt Menu select Go back to the upper level of the menu v Enter key to go to a sub menu 4 1 Profile Download and Save Profiles If the user selects the factory default profile the system will restart before downloading the factory default profile User can configure Line Code HDB3 AMI and Loopback test After selecting the user defined option the system will automatically restart The system will then download the user custom profile Modify Password To prevent unauthorized login user must enter a set of password to login to the system The password for is a combination of the buttons below from left to right Button Up Right gt Down Up Password U R D U User can change the password using this function
4. FMUX03 E1 T1 DSU CSU Digital Access Units STANDALONE TYPE Fiber Optical E1 T1 Multiplexer INSTALLATION and OPERATION MANUAL Cre CTC UNION TECHNOLOGIES CO LTD CTC Union FMUX03 Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Appendix Table of content DNIPOGUCTION UEM 1 1 Functional 2 1 2 1 2 Applications of 3 2 1 3 FMUX03 Technical 1 4 FMUX03 Ordering Information eene Installationoe Zed 252 MIN PACKING 2 353 Pr 2 4 Site Selection o oo e ge E E 2 5 DC or AC Electrical Outlet Operating Instructions 3 1 Front Panel oei eoa e oe oma e ha Gide oes 3 2 Front Panel Control and LED Indicator Functions 3 3 Menu Mic I Operating and Setup Instructions cessere OU EYE 4 3 Trunk Link Stonal eire en eee nen nnn 4 4 Optical Module Manual Switch 4 5 Craft Port Operation iie e ee EE ieee 4 6 Connect and setup the craft 4 7 Operating
5. From The Craft Port esee Diagnostics and Loopback Je Generals io nee 52 sedciilsiutis d ET 1 DB25 Pin Assignment for Tributary E1 Line Connection A 2 Pin Assignment for Tributary 1 Pad A 3 Alarm FMUX03 Chapter 1 Introduction 1 1 Functional Description The CTC Union s FMUXO3 is a fiber optical multiplexer that integrates 4 8 16 channels of 1 signal into a single optical data stream It extends the transmission distance up to 80 kilometer With the optional secondary optical link FMUX03 provides 1 1 optical line protection In addition FMUX03 also provides the standard SNMP interface for Network Management using Ethernet and PPP ports to connect to central office User can monitor the FMUX03 through built in In band operation channel to reach a remote terminal Moreover FMUX03 simplifies testing and maintenance with order wire allowing communication between local and remote maintenance crews The FMUXO3 provides the telecommunication company multipurpose and easy to use high quality fiber optics multiplexer lt use of FMUX03 with the Smart Agent network interface for ease of network connectivity lt Provides both 10 100 Base T and PPP interface to connect SNMP Network Management center interface system lt Optional secondary fiber link offers 1 1 line auto protection to insure network quality and eff
6. Loopback Local Side Loopback tests the path between local and remote 1 El Local Loopback Local side Remote side AIS for any loopback channel lt 4 2 El Remote Loopback Local side Remote side b HE 1 AIS for any loopback channel 24 FMUX03 3 Optical Local Loopback Local side Remote side All AIS gt lt 4 Optical Remote Loopback Local side Remote side Remote side 1 El Local Loopback Local side Remote side gt E1 AIS for any loopback channel 2 1 Remote Loopback Local side Remote side 1 AIS for any loopback channel 3 Optical Remote Loopback Local side Remote side db 25 FMUX03 4 Optical Local Loopback Local side Remote side All AIS p lt 26 CTC Union FMUX03 APPENDIX A 1 DB25 Pin Assignment for Tributary E1 Line Connection 1 Li e Or SUM Ch2 Tx pair TX T2 P 3 9 RX_R2 16 Ch2 Rx pair O O4 4 RX_T2 P H RX RI pair 18 Tl O COS TX RI 19 Chl Tx pair 5 GNDF ao O Oi z dup PX Ch4 Tx pair 9 RX R4 Q m Ch4 Rx pair
7. a remote terminal emulator such as VT100 4 6 How to connect and setup the craft port Connect the craft port to a remote terminal using DB 9 cable VT100 terminal settings Bit Rate 9600bps Data Bit 8 bit Parity No Parity Stop Bit 1 Stop bit Set the emulation mode to VT100 or Detect 4 7 Operating From the Craft Port After properly connecting the craft port to a terminal the system will prompt the user for password The universal password is 1234 FMUX03 The figure below is a screenshot of the login terminal screen FMUXO3 V1 0 Key in Password _ User can access a function by typing its corresponding number into the remote terminal go back to the previous menu press the Backspace key Refer to the Menu Tree for navigation After entering the remote terminal screen user can select Local Side operation and Remote Side operation for configuration loopback and monitoring of the FMUX03 Local Re FMUXO3 V1 0 l Local Side 2 Remote Side Please select the item or Backspace to previous menu Local Alarm Report Sys O E1 CHL CH O E2 CH3 CH4 Remote Alarm Report OZEL CH1 CHZ O E2 CH3 CH4 FMUX03 After entering the main menu select of the nine functions Profile Configuration 1 Status Report Alarm Report Optical Configuration PM Sta
8. ack and Request Remote Loopback Trunk Link Local Loopback and Remote Loopback FMUX03 gt ACO Alarm cut off gt RST Reset button Configuration gt Use the 3 control buttons and the LCD front panel to configure and monitor the system gt Craft port with DCE appearance gt Bits per second baud 9600bps gt Parity None gt Bits 8 bits gt Stop Bit 1 VT 100 or Emulation Terminal Power gt DC 36V 72V gt 90 288V 47Hz 63Hz Physical Specifications gt FMUX03 Dimensions Depth Width Height FMUX03 4 220mm 285mm 44 5mm FMUX03 8 16 440mm 285mm 44 5mm gt Optical Link FC PC or ST Electrical Link DB 25 female connector Order Wire Microphone and headset Network Management Center Interface RJ 45 and DB 9 connector Alarm Connector DB 9 connector Environment Operating Temperature 0 40 Indoor Version 0 60 Outdoor Version 25 70 C Storage Humidity 5 95 gt EMI Comply with CISPR 22 standards A EN55022 and FCC Part 15 rules FMUX03 gt EMS Comply with EN55082 2 standards gt Safety Complies with EN60950 standards 1 4 FMUX03 Ordering Information Options for Ordering Information FMUX03 X XX XXXX X X XX X Optional Feature S Surge Protection Power Module Single 90 288 VAC power supply AC2 Dual 90 288 VAC power supply DC1 Single 34 72 VDC powe
9. after verifying the current password Password can also be changed from the craft terminal using the same procedure Note that the password for operating the craft can be different from LCD menu driven is needed Note In case the user forgets the login password the universal password for FMUX03 1234 can be used 4 2 E1 Configuration There are two types of loopback tests for E1 configuration Local Loopback and Remote Loopback perform the test on an individual E1 channel or all channels select the function CH n or Note Refer to Chapter 5 for detailed information on Diagnostics and Loopback Functions 4 3 Trunk Link Signal There are two types of loopback tests for the Trunk Link Signal Local Loopback and Remote Loopback Note Refer to Chapter 5 for detailed information on Diagnostics and Loopback Functions O E Module status can be obtained from this current menu Under normal operation LCD display shows that the working O E module as Working and the backup O E Module as Standby If FMUXO3 detects a Loss of Signal the LOS light will be lit and the LCD display will show that there is a Loss of Signal 4 4 Optical Module Manual Switch Users can manually which between O E module 1 and O E module 2 if a secondary O E module is installed on the FMUX03 4 5 Craft Port Operation Craft port allows user to monitor and configure FMUX03 through
10. e is a Major Alarm present 4 MIN Yellow light when there is a Minor Alarm present 5 RNG Red light when connected to the remote terminal SYS System normal or System failure RDI Remote Defect Indication Indicates a failure in the remote terminal 8 LCK System Lock Locks the system if switched to protect line 6 times within 10 minutes 9 JACO Alarm Cut Off Yellow lights when the ACO button is pressed to manually disable the audible alarm when a problem occurs If any newer alarm is reported after the ACO button has been pressed the external alarm will activate again 10 CAL Order wire 11 RST Restart the system 12 These three buttons serve as the control and configure FMUX03 FMUX03 DB 25 pins female for El interface Power Switch AR RTNFCND A 0 0 AC 11 2 A oCo LAN PPP Alarm DB9 AC amp DC Power Terminal Connector Rear panel I El I O DB25 female connector for input output of El signal II Alarm DB9 female connector Connect to an external BUZZER to receive visible and audible alarm Terminal Connector LAN PPP connector to remote terminal using RJ45 IV Power Switches On Off switch for FMUX03 lt There are 5 different power supply combinations with the DC AC dual modu
11. elecommunication equipment to withstand electrical surge that may result from lighting strikes FMUXO3 has been tested and found to comply with the FCC requirement Users should follow the precaution below to insure the safety and minimize the risk of damage to the equipment Make sure that the power outlet is properly grounded Please refer to article 250 of the National Electrical Code NEC Handbook Proper grounding should include a minimum of 1 A grounded rod buried outside the building at least 8 feet 2 44 meters deep 2 It is preferred that the building uses metal water pipe and cooper connector at the joint 2 Any device connected to FMUXO3 either directly or indirectly should use the same set of power outlet FMUX03 2 4 Site Selection For best performance install the FMUXO3 within 50 feet 656 meters from the data terminal equipment and 6 feet 1 83 meters from the AC power outlet To allow easy access to the equipment leave at least 36 inches 90 cm clearance in front and at least 4 inches 10 2 cm at the rear To avoid overheating leave at least 1 inch 2 5 cm on either side of FMUXO3 Also do not stack another equipment on top of FMUX03 2 5 AC or DC Electrical Outlet Connection For safety and to prevent damage to FMUXO3 make sure that the power requirement matches those of your electric outlet Connect power to FMUX03 and power on the equipment CTC Union FMUX03 Chapt
12. er 3 Operating Instructions 3 1 Front Panel There are four parts to the front panel of FMUX03 1 Fiber Optics Connectors and Indicators Two sets of optics transmit receive and indicators one working and another as protect Notifies user of a problem such as LOS Loss of Signal and Laser LED LSR 2 Alarm LED Display Notifies users of a problem such as LOS Loss of Signal and AIS Alarm Indication Signal for each of the four El channels 3 LCD Control Buttons The three buttons and are used for system configuration and for the loopback test 4 Order Wire User can connect FMUXO3 to a headset and microphone for ease to remote configuration and testing Each of the LED indicators is described below in detail Front panel LED Display CTC Union Technologies Co Ltd OLOS1 OLOS2 LE LSR LSR2 1 LOS AIS 30 0 Fiber Optical Connector LCD Control Order Working and stand by Button Wire CTC Union FMUX03 3 2 Front Panel Control and LED Indicator Functions refrence appendix Control or LED Indicator Function 1 OLOS1 Red light when there is a loss of input signal OLOS2 Orange light when there is a loss of output signal LSRI LSR2 Yellow light signals an alarm in Laser sending out energy normally 2 LOS AIS Red light when there is a Loss of Signal LOS Yellow light when received an Alarm Indication Signal AIS 3 MAJ Red light when ther
13. figuration Near_end Setting 1 Device IP cur 0 0 0 0 2 Host IP Cure 0 0200 3 Net Mask cur 0 0 0 0 4 Gateway CUES 192 168 101 5 MAC cur 00 00 00 00 00 00 Please select the item or Backspace to previous menu Local Alarm Report Sys P2 F 1 108 1 10 2 5 2 105 CH3 AIS CH4 AIS Remote Alarm Report sys O El CH1 CH2 O E2 CH3 CH4 22 CTC Union FMUX03 Near_end Setting System Information l Time 23 39 44 37 15 1993 2 System Name FMUXO3 35 4 System Location Taiwan Taipei 5 Write Community private 6 Read Community public Please select the item or Backspace to previous menu _ Local Alarm Report Sys P2 F O E1 LOS CH1 LOS CH2 AIS 2 105 CH3 AIS CH4 AIS Remote Alarm Report Sys O El CH1 CH2 2 CH3 CH4 23 FMUX03 Chapter 5 Diagnostics and Loopback Functions 5 1 General Information This chapter contains detailed information on the diagnostics and the loopback tests of FMUXO3 fiber optics transmission equipment User can activate the loopback function to diagnose the full service 5 2 Loopback Functions for E1 Tributary There two types of loopback functions for the Module Local Loopback and Remote Loopback User can select whether to diagnose a specific channel or all channels under the E1 Configurations options Figures below illustrates the concepts of the loopback function Local Side
14. iciency lt In band operation channel provides the ability to configure test and monitor system status and alarm from both local and remote terminal FMUX03 offers real time monitoring of the transmission quality to meet the demands of high quality communication lt El signal control calculates error in Path and Line lt fiber optical interface of E1 communication system complies with the requirement of ITU T regulatory standards lt gt Order wire to assist with remote maintenance configuration and testing lt Provides the parity error count for optical interface performance monitoring lt Operating from dual AC DC selectable power module co exist on FMUX03 backup power supply is available Mountable on either 19 inch or 23 inch rack CTC Union FMUX03 1 2 Applications of FMUX03 FMUXO3 is mainly used to extend the transmission distance of E1 signal by multiplexing four individual E1 channels into a single optical data stream As illustrated below there are three main applications for the use of FMUX03 gt Application 1 FMUXO3 integrates 4 8 16 channels into a single optical data stream gt Application 2 FMUXO3 can connect rDSLAM to a remote Central Office gt Application 3 FMUXO3 can connect a Base Station BS to a Base Station Control BSC Remote Side A 1 Application 1 Remote Side Q SNMP R DSLAM p Ul H Optical Link B
15. le power supple AC only DC only dual AC dual DC both AC and DC Reference to Order Information CTC Union FMUX03 3 3 Menu Tree FMUX03 V1 0 1 Local 1 Profile WA 1 Download Default 2 Remote 2 Download User Defined 4 3 Save User Defined gt 4 Password Modify 5 Logout 2 El Config 1 CHALL V gt 2 CHI 1 Line Code ZDB3 AMT gt co B 2 Framer OWOFF CH3 3 Local Loopback gt 2 gt 4 Remote Loopback OF FYON 5 El Service eut 3 Channel Linecode Framer LocalLoopback RemoteLoopback Service 5 CH4 3 E1 Status Report 4 Alarm Report 1 System Alarm 1 Board Fail gt 2 Power Fail 3 Power2 Fail 2 Optical Alarm 1 LOS e mes 3 E1 Alarm gt El AIS 19581 4 4154 LOF 4 5 Optical Config YA 1 Optical 1 Working gt 2 Optical 2 LOS Standby Working 4 3 Switching Release Lock 4 Local Loopback OFE ON 5 Remote Loopback OFF ON Standby Optical Disable Function OFF ON Y 6 PM Status Report 1 Current 1 1 Line CV EBV 1 2 ES El 4 Path Trunk CRC ES Optical SEC gt UAS gt 2 History Interval Please key in time interval hh q gt 3 History Day Please key in history day 1 7 4 Reset PM 1 Reset Current PM Br 2 Reset All Interval PM gt 3 Reset 7 days PM 12 gt 3 Reset 7 days Y v 7 PM Threshold LEI Interface LLine
16. output signal in the absence of input jitter shall not exceed the following limits in both bands simultaneously Jitter output should meet the requirement after FMUX03 performs the loopback test without jitter for E1 input signal Connector Type DB 25 female connector CTC Union FMUX03 Optical Link Wavelength 850 1310 or 1550 nm MLM Laser diode Number of Optical Link 2 working and protection link Output Power gt 12dBm at 62 5 125 850 nm Laser gt 2dBm at 9 125 1310 nm Laser gt 2dBm at 9 125 1550 nm Laser Receiver Sensitivity gt OdB Laser 850nm gt 32dBM Laser 1310 nm or 1550 nm System Gain gt 2 14dB Laser 850nm gt 20 30dB Laser 1310nm or 1550nm Fiber type Single Mode 9 125um or Multi Mode 62 5 125um Connectors FC PC SC or ST Alarm Detection and Indication Tributary Interface LOS Loss of Signal The loss of E1 signal AIS Alarm Indication Signal Alarm indicator Optical Interface VV ON ON ON LOS Loss of Signal The loss of optics signal LCK Lock Prevent switching to protect line RDI Remote Defect Indication Remote alarm Laser On Laser On indicator System Power and Control Module Normal failure detection Alarm Connector DB 9 female connector Connect to an external BUZZER to receive visible and audible alarm Diagnostic capabilities Tributary Local Loopback Remote Loopb
17. r supply DC2 Dual 34 72 VDC power supply AD AC DC dual power supply Fiber Optical Connector F FC PC type fiber connector T ST PC type fiber connector S SC PC type fiber connector Fiber Optical Module S Single OE module D Dual OE module Fiber Optical Wavelength 850 850nm multi mode 1310 1310nm single mode 1550 1550nm single mode Interface module EIB 120 ohm balanced EIU 75 ohm unbalanced 100 ohm V35 V 35 data port single port only Port Number 4 4 ports 8 8 ports 16 16 ports FMUX03 Chapter 2 Installation 2 1 Description This chapter provides the information needed to install It is important to follow the installation instruction to insure normal operation of the system and also to prevent damage due to human error 2 2 Unpacking If there is a possibility for future relocation of the FMUXO3 unit please save the cartons and protection packaging material The following items are shipped with your FMUX03 FMUXO3 User s Manual One FMUXO03 Unit Depends on what was ordered either DB 25 wire wrapped adaptor or DB 25 Mini Terminal Block Please carefully unpack and inspect the unit and accessories for damaged and missing parts Contact our nearest sales representative or our company directly if you suspect any damaged or missing parts Improper handling during shipment may cause early failure 2 3 Site Requirements The FCC requires t
18. revious menu _ Local Alarm Report Sys 1 CH1 CH2 CHS CH4 Remote Alarm Report Sys 1 CH1 CH2Z O E2 CH3 P PM Report Near end Setting Current History interval History day Please select the item or Backspace to previous menu Local Alarm Report Sys Remote Alarm Report Sys O E1 O E2 O E1 O E2 CH1 CH2 CH3 CHA CH1 CH2 CH3 CHA 20 CTC Union FMUX03 PM history Line CV Line ES Ch 1 0 0 Ch 2 0 0 Ch 3 0 0 Ch 4 0 0 PM History Report Before Current hour 00 quarter 1 Path CV 0 0 Path ES 0 0 Path UAS 0 0 Local Alarm Report Sys OZET CH1 CH2 O E2 CH3 Remote Alarm Report Sys GHT CH2 O E2 CH3 CH4 PM threshold Ch All Oy Cn 4 CO P2 rA Line Line Path Path Path Path Near end Setting CV ES CV ES SEC UAS Please select the item or Backspace to previous menu Local Alarm Report Sys O E2 Remote Alarm Report Sys O E2 CH1 CH3 CH1 CH3 CH2 CHA CH2 CH4 21 CTC Union FMUX03 PM report Ch All Line CV Near_end Setting 1 15 mins cur 0 2 LAE cur 0 3 24hrs cur Please select the item or Backspace to previous menu Local Alarm Report Sys O El1 CH1 CH2 O E2 CH3 Remote Alarm Report Sys O El1 CH1 CH2 O E2 CH3 CH4 Agent network Agent Network Con
19. tus Report PM Threshold Setting Agent Network Configuration 29 cg Os ast aus dus quce System Information Mam Main Menu Near end Setting Profile El Configuration El Status Report Alarm Report Optical Configuration PM Status Report PM Threshold setting Agent Network Configuration System Information CD OY O1 4 Co Please select the item or Backspace to previous menu _ Local Alarm Report Sys P2 F O El LOS CH1 LOS CH2 AIS 2 105 CH3 AIS CH4 AIS Remote Alarm Report sys O El CHL CH2 O E2 CH3 CH4 18 CTC Union FMUX03 Ch All Configuration Near_end Setting Line code HDB3 Framer CEPT with CRC4 Local Loopback OFF Remote Loopback OFF El Service ON CO WN IP Please select the item or Backspace to previous menu Local Alarm Report Sys O E1 CH1 CH2 O E2 CH3 CH4 Remote Alarm Report Sys 1 CH1 O E2 CH3 CH4 Main Menu Near_end Setting E_Code Alarm 0 Ch 1 LOS Please select the item or Backspace to previous menu Local Alarm Report Sys CH1 LOS CH2 O E2 CH3 CH4 Remote Alarm Report Sys 1 CH1 Chet O E2 CH3 CH4 19 CTC Union FMUX03 Optical Wher Optical Configuration Near_end Setting Optical 1 Working Optical 2 Standby Switching Release Local Loopback OFF Remote Loopback OFF Please select the item or Backspace to p