Clean Air Box Series Calibration Kit User Manual
Contents
1. Mat Tools 800 577 6389 www netzerotools com netzerotools com Clean Air Box Series Calibration Kit User Manual Kit includes Kit CO Cylinder Zero Air Hardware CABCKI L 17L 10 ppm WAL Regulator CABCG1O17L CABCGO17L tubing fitting CABCK 34L 10 ppm 34L Regulator CABCG10 CABCGO tubing fitting carrying case CABCK103L 103L 10 ppm 103L Regulator CABCG10103L CABCG0103L tubing fitting carrying case A WARNING Bullard recommends using impurity free test gas to perform Zero adjustment Bullard Zero air CABCGO Failure to observe this recommendation may cause premature failure of the sensor A WARNING Use only 10 ppm CO gas for calibration Using a higher concentration may produce an inaccurate calibration and may damage the sensor Bullard CO gas CABCG1O Zero Point Adjustment 1 Connect compressed air source to CAB or COHP 2 Allow air to pressurize system for 5 10 minutes 3 Perform zero point adjustment and calibration NOTE If the unit is experiencing a temperature change of more than 20 degrees wait 15 30 minutes before beginning calibration sequence Zero calibration should be performed before calibrating the monitor with CO gas Use impurity free test gas Zero Adjustment Procedure Remove the front cover of the CO Monitor Push the ON button The unit will beep and begin a 60 second countdown AC will appear on the display Press and hold the On Off butto
2. e describe the air turned off If the problem persists contact the Bullard Customer problem as completely as possible For your convenience the representative Service Department at 1 877 BULLARD will try to help you correct the problem over the phone 2 Verify with your representative that the product should be returned to Bullard Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products suspected to be contaminated will be professionally discarded at the customer s expense 4 Ship returned products including those under warranty with all transportation charges pre paid Bullard cannot accept returned goods ona freight collect basis 5 Returned products will be inspected upon return to the Bullard facility Bullard Customer Service will telephone you with a quote for required repair work which is not covered by warranty If the cost of repairs exceeds stated quote by more than 20 your coordinator will call you for authorization to complete repairs After repairs are completed and the goods have been returned to you Bullard will invoice you for actual work performed Bullard CAB100HA Clean Air Box Breathi
3. n until it beeps AO will now appear on the display N OW Ol 7A W N FF Attach the regulator to the zero gas cylinder Rotate the knob located on the front of the CO Monitor to the CAL position 8 Insert the calibration connector fitting into the center of the knob on the front of the monitor 9 Open the cylinder valve fully The flow rate is preset so there is no need to adjust it 10 The red LED will continue to blink for approximately 90 seconds during which the zero adjustment process will take place 11 Watch for the green LED to begin blinking This indicates a successful zero 12 Verify by turning knob to TEST LCD display should alternate between CO and O or 1 If this does not occur wait 5 minutes and re zero 13 Close the regulator on zero gas cylinder completely Remove the calibration connector fitting from the center of the knob note Knob must be in RUN position for active monitoring of CO in the air Supply 14 With the incoming air flowing turn the knob to RUN Calibration Instructions Monitor calibration should be performed monthly or whenever the reading may be questionable A calibration schedule should be maintained for future reference To obtain an accurate calibration we recommend the use of Bullard calibration kits Calibration Procedure Calibration is recommended only after a zero so the unit will already be on Rotate the knob located on the front of the monitor to the CAL
4. ng Filtration System Bullard CAB50HAS5 Clean Air Box Breathing Filtration System Bullard CAB30IRHA Clean Air Box Breathing Filtration System Bullard CAB50HA Clean Air Box Breathing Filtration System Bullard CAB30HA Clean Air Box Breathing Filtration System netzerotools com
5. position AC will appear on the display Attach the regulator to the calibration gas cylinder 10 ppm CO required Insert the calibration connector fitting into the center of the knob Open the cylinder valve fully The flow rate is preset and there is no need to adjust it The Red LED on the front of the monitor will continue to blink for approximately 90 seconds during which the calibration process will take place netzerotools com Ss Mat Tools netzerotools com 800 577 6389 www netzerotools com Watch for the green LED to blink This indicates a successful calibration Return Authorization 10 1 If this does not occur wait 5 minutes and repeat calibration returned goods Please read carefully Close the regulator on CO gas cylinder completely and remove the calibration Follow the steps outlined below to return goods to Bullard for repair or connector fitting from the center of the knob replacement under warranty or for paid repairs Rotate the knob to the RUN position 1 Contact Bullard Customer Service by telephone NOTE Knob must be in RUN position for active monitoring of CO in the air Supply The monitor is now calibrated and should be recalibrated monthly or ona schedule with local requirements NOTE Typical calibration takes approximately 90 seconds If unit will not calibrate within 3 minutes repeat the calibration steps with compressed In your correspondence or conversation with Customer Servic
Download Pdf Manuals
Related Search
Related Contents
Manual Opel Meriva 2011 1 a - Sistemas SET - Universidade de São Paulo Painless Performance LS1 User's Manual Chicago Electric 3914 Sewing Machine User Manual Anexo 01 Electro-Voice PI115L User's Manual Manuel d`utilisation et de montage ZTM-45/25 RT & ZTM-45/25 J RT Spécifications Jeux de société NAVIGON 25xx Explorer Copyright © All rights reserved.