Home

AN-X-DCSNet2 Communication Module User Manual

image

Contents

1. d0000 h Card Driver Status Unknown State Stat _ Stop AN X DCSNet Ethernet Gateway AN IP Address i 92 168 1 48 V Enable AN X DCSNet Link r Command Central Current RSLinx CIP Path m Performance Options YDD Wait Period Auto X eea a Configuring the Programming Software To configure the AutoMax Programming Executive to use AN X 1 Run the Programming Executive 2 Select Setup Communications The Communications Setup dialog appears A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 20 AN X DCSNet2 7 You should now be able to go online with the AutoMax Programming Executive Multiple Programmer Access Communication Setup Communication Type C Serial Port Internal PC3000 PC Link Interface Module November 2011 Serial Port Com 1 Com 2 Baud Rate 19200 2 Drop E Segment 0xD000 z Port Addr 0x250 z PC Link Interface Module rinternal PC3000 Card ID Segment Port Addr Set the Communications Type to PC Link Interface Module Set the Drop to match the AN X drop number on DCS Set the Segment to match the Memory Address in the VDD Configuration Set the Port Addr to match the Port Address in the VDD configuration Click OK to complete the configuration The AutoMax operating syst
2. network The name can be from 1 to 31 characters long To configure the AN X to obtain its IP address from a DHCP server on the network select Obtain an IP address automatically DHCP To configure the AN X to use a static IP address select Use the following Settings and enter the following e the desired IP address for the AN X e the Subnet mask for the AN X e the default gateway for your network You must enter a valid default gateway address even if there is no device at the gateway address on the network Click OK to complete the configuration Utilities AN X IP Configuration resets the selected AN X Use the Utilities Restart AN X to restart the AN X in production mode If you Cancel the Utilities AN X IP Configuration command AN X is left running the boot code Use the Utilities Restart AN X command to restart the AN X Restart an AN X Use the Utilities Restart AN X command to restart the currently selected A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 40 AN X DCSNet2 AN X Info November 2011 The Utilities AN X Info command provides information about the currently selected AN X in the log window The information shown AN X Info Ethernet MAC address SerNum Serial number DaughterID Daughterboard ID 3 for AutoMax BootRev Boot code version ConfigRev
3. 7 Cancel Help Enter the Name Use the host name you assigned to AN X when you configured its IP properties Set the Slot to 16 and the chassis size to 17 Set the Comm Format to None Set the IP address to match the AN X module Set Electronic Keying to Disable Keying Click OK to accept the settings 2 Add Generic modules for each scheduled connection Right click on the backplane and select New Module From the Other category select 1756 MODULE A product of Quest Technical Solutions RS Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 25 New Module 1756 MODULE Generic 1756 Module ANXDCSNet Connection Parameters Assembly Instance Size Name AnwSlot0 Input 250 16 bit Description Output 248 16 bit Configuration 4 0 3 bit Comm Format Data INT Slot 0 V Open Module Properties i i Help Set the Name and Description as desired Set the Comm Format to Data INT Set the other parameters as shown Set the Slot to 0 for connection 0 1 for connection 1 and so on 3 Set the RPI for each connection IMPORTANT Ensure that any check box that refers to Unicast connections is i unchecked A product of Quest Technical Solutions a es Sold and Supported by ProSoft Technology Inc PROSOEFET www prosoft technology com PARTNER PROGRAM eA SOLUTIONS Page
4. DCS Slave Sample File DCS Master Sending the Configuration to AN X Viewing the Current Configuration Error Log Exporting Aliases from AN X Using RSLogix 5000 to Diagnose Problems General Tab Connection Tab USING ANXINIT Anxlnit Log Locating Available AN X Modules Selecting an AN X Set AN X IP Configuration Restart an AN X AN X Info Read Kernel Parameters Run Config Mode Update AN X Flash Update Firmware Firmware Update Wizard Update Firmware Command Patch Firmware A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com November 2011 23 34 34 34 35 35 36 36 37 38 38 39 40 40 4 4 42 42 46 46 USING THE WEB INTERFACE DCSNet Configuration Configure ControlLogix Support View Configuration Files View Active Configuration Monitor DCS Data Log Files System Error Log System Info Log ControlLogix Log View All Logs Administration Menu Browse File System AN X IP Configuration Archive Configuration Restart AN X Module TROUBLESHOOTING LEDs Ethernet LEDs SYS LED NET LED DCS Network Status DCS Diagnostic Counters UPDATING THE FIRMWARE Reading Version Numbers SPECIFICATIONS SUPPORT WARRANTY 48 48 50 50 51 53 54 54 54 54 54 54 54 55 57 61 61 62 63 64 AN X DCSNet2 Module Overview The AN X DCSNet2 firmware runs on an AN X AutoMax communications module and connects a com
5. Data definitions consist of lines that define the mapping between the ControlLogix data table and the DCSNet data They are of the form CLXoffset drop register length For example the entry 200 4 0 10 maps 10 registers starting at drop 4 register 0 to offset 200 in the current section If the offset is omitted AN X automatically assigns an offset based on the previously mapped data For example to automatically map the same data as the previous example use 4 0 10 The maximum size for each section is 250 input registers and 248 output registers Anything after a semicolon on a line is treated as a comment and is ignored You can use this to document the file by adding comments to the ends of lines or as separate lines Output Data If the AN X DCSNet is a DCS slave the only valid entries are DCS registers 0 31 on drops included in the AN X drop number and drop A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 31 depth For example if the drop number is 7 and the depth is 3 only drops 7 8 and 9 can be used in output data mappings If the AN X is a DCS master the only valid entries are registers 32 63 on drops 1 to 55 and registers 32 39 on drop 0 Input Data Any DCS data can be mapped to ControlLogix inputs Input data mappings can be up to 250 words long and can span multiple DCS
6. IP address from a DHCP server or to time out and use its default IP address about 3 minutes Select the second option on the screen and click the Next gt gt button Step 3 If you powered off the AN X turn it back on Wait for AN X to enter boot mode While AnxInit is waiting the Next gt gt button is disabled When AN X is in boot mode the Next gt gt button is enabled A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER AL PROGRAM SOLUTIONS AN X DCSNet2 Page 11 Step 3 Wait for Boot Mode If you selected the Cycle Power option power ON the AN lt module now If you selected the Reset Command option a reset command has been sent to the AN module This program is now sending messages to the 4N module using the MAC address and IP address you entered previously These messages tell the AN lt module to remain in its Boot state in preparation for configuring the IP settings If the AN module enters Boot mode successfully the Next button below will be enabled so you can move on to the next step If the AN module has been powered ON for more than 10 seconds and the Next button is still disabled press the Back button confirm the MAC and IP addresses and check the Ethernet cabling If the AN X does not enter boot mode within about 10 seconds return to the previous screens and check the entries The AN X TCP IP Conf
7. before you can install a new version Use the Windows Control Panel Add and Remove Programs to remove the old version Insert the CD supplied with the AN X module and run the program setup exe on the CD A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 7 Ethernet Configuration The AN X DCSNet2 module connects a computer or other device on Ethernet to a Reliance DCS network Before you can use the AN X DCSNet2 you must configure its Ethernet network properties Ethernet Configuration AN X can be configured to use a static unchanging IP address or it can be configured to obtain its IP address from a DHCP server Unless you have control of the DHCP server in most applications you will configure AN X to use a static IP address Otherwise the DHCP server may assign a different IP address each time AN X powers up and any software that accesses the AN X module would have to be reconfigured AN X is shipped with DHCP enabled If it finds a DHCP server on the network the DHCP server assigns it an IP address You can use the utility AnxInit to find the IP address that the DHCP server has assigned Select Utilities Locate All AN X Modules and AnxInit will locate the AN X and display its IP address I Local Area Connection 2 0x2 00 Oc 1a 00 00 0a 192 168 0 10 Anxinit EBK Configuration Utilities Edit View
8. normally used internally for updating firmware This command is not used in normal operation but may be required for technical support The AN X is in configuration mode when the SYS LED flashes red twice followed by a pause To exit configuration mode use the Utilities Restart AN X command to restart AN X in production mode Update AN X Flash The Utilities Update AN X Flash command updates the low level firmware configuration and production kernels Files have extension qtf and are found on the AN X distribution CD This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command If you cancel at the filename dialog the AN X has already been reset and is in boot mode Use the Utilities Restart AN X command to restart it in production mode A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com eA SOLUTIONS Page 42 AN X DCSNet2 November 2011 Filename _ almage prod v1 01 0001 qtf Files of type jars Flash File tf Cancel Open as read only Update Firmware There are two ways to update all the firmware in an AN X module 1 The Configuration Firmware Update command starts the firmware update wizard which takes you step by step through the firmware update process 2 The Utilities Update Firmware command updates all the firmware on an AN X you have selected using the
9. the boot code Use the Utilities Restart AN X command to restart the AN X You can also reconfigure the AN X IP parameters from the web interface Refer to page 55 Example Standalone Computer TIP AL SoLuTIONS A typical example is a laptop computer running the AutoMax programming software and connecting directly to an AN X to program an AutoMax processor Since you are connecting directly from the computer to AN X use a crossover Ethernet cable The following instructions assume that an Ethernet network card has been installed in the computer and that AnxInit has been installed on the computer The parameters in this example will work when you set up any standalone computer to work with AN X First configure the computer to use a static IP address From the Start menu select Start Settings Network and Dialup Connections Double click on Local Area Connection A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 13 Local Area Connection Status General Connection Status Connected Duration 01 57 12 Speed 100 0 Mbps Activity az Sent 3 Received Lb Packets 956 885 Disable Click the Properties button Double click on Internet Protocol TCP IP Internet Protocol TCP IP Properties General You can get IP settings assi
10. the web interface The archive file is a standard gzip compressed tar archive Select Administration Archive configuration Click on the Archive File link and save the file Select the destination where the file will be stored A product of Quest Technical Solutions Bd Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 57 Restart AN X Module The Restart AN X Module command is password protected and is intended for technical support Googe o x v Automation Network Y Log Files 3 Restricted Access v Administration password ay Submit A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com eA SOLUTIONS Page 58 AN X DCSNet2 November 2011 Troubleshooting LEDs The AN X DCSNet has LEDs that indicate the state of the Ethernet connection the connection to the DCS network processor and the overall module state Ethernet LEDs There are two LEDs that indicate the state of the Ethernet connection The orange LED labelled 100 is on if the link is running at 100 Mbits second and is off otherwise The green Link Act LED is off if the link is inactive and is on if the link is active If activity is detected the link blinks at 30 ms intervals and continues blinking as long as activity is present SYS LED The SYS LED is used by the AN X operating syst
11. 17 DCSNet Configuration You set the DCS mode of operation master or slave and the drop number and depth using the web interface Start your web browser and enter the AN X IP address as the address Select Automation Network DCSNet Configuration to set the DCS drop number and depth Elle View History Bookmarks Tools Help n DC GB oe httprsp192 168 1 497 vw 4 Lord Peter Wimsey P2 drs AN X DCSNet2 Web Interface v3 2 1 v Automation Network AN X DCSNet2 Configuration EEC Slave Drop Nurnber Drop Depth AN X DCSNet can be used as a DCS master or slave Check Master or Slave to select which one you want If the AN X DCSNet is a DCS slave enter the Drop Number and Drop Depth These entries are ignored if the AN X is a DCS master Click the SUBMIT button to send the values to AN X AN X defaults to DCS slave operation with drop number 55 and drop depth 1 For further details refer to page 48 A product of Quest Technical Solutions gt Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM eA SOLUTIONS Page 18 AN X DCSNet2 November 2011 Using the AutoMax Programming Software Any computer with Ethernet access can use an AN X DCSNet module to connect to an AutoMax processor over DCSNet The Virtual Device Driver runs under Windows XP or Windows 7 but eerie does not run und
12. 2 40 ConnStats2_ offset 40 Sample File DCS Slave The following sample file shows how data is mapped for an AN X configured as a DCS slave at drop 2 depth 4 The AN X is also monitoring all the data on drop 1 on the same network ClxName DCS2slave ClxPrefix ANX3 AN X is drop 2 depth 4 drop 1 is monitored ClxSlot 0 DataOutput 72 9732 30732 1 0 32 7079732 DataInput 2 32 32 r3r32r32 r4 32 32 EE EAE FA ClxSlot 1 DataOutput DataInput 705 0732 0 32 8 1 0 64 Cixsiet 15 DataOutput DataInput connStats0 connStatsl A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SoLuTIONS AN X DCSNet2 Page 33 ConnStats15 Sample File DCS Master The following sample file shows how data is mapped for an AN X configured as a DCS master ClxName DCSmaster ClxPrefix DCSmaster2 ClxSlot 0 DataOutput 7073278 plz732 32 12 32 32 DataInput 170732 72 0 32 Cissilot 15 DataOutput DataInput 0 0 32 connStats0O connStats15 Sending the Configuration to AN X When the configuration is complete save it to a file If you are using a spreadsheet to create the configuration save it as a file of type comma separated variable CSV To send the configuration to the AN X Start your web browser Enter the AN X IP address as the address for example 192 168 0 10 Select Automation Network Confi
13. 26 AN X DCSNet2 November 2011 E Module Properties ANXDCSNet 0 1756 MODULE 1 1 General Connection Module Info Backplane Requested Packet Interval RPI 50 04 ms 0 2 750 0 ms Inhibit Module l Major Fault On Controller If Connection Fails While in Run Mode Module Fault Status Offline AN X supports RPIs from 5 to 750 ms Select an RPI appropriate to the DCS network scan time and to your application The approximate DCS network update time is 3 ms per drop The DCS network update time is given by Update time DropTime N NewDropTestTime MessageTime where DropTime the amount of time for a master to send a message and the slave to respond 2 99 ms N Number of slave drops physical and virtual NewDropTestTime amount of time for the master to poll an inactive drop and wait for its response 2 48 ms assuming no response MessageTime amount of time to transfer programming terminal messages If the master is sending a message this is 2 09 ms If a slave is sending a message this is 3 395 ms Example A network composed of 10 drops with no messaging updates each drop with a period of UpdateTime 2 99 10 2 48 32 38 ms A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 27 Input Only Connection The AN X DCSNET2 supports one input on
14. AN X DCSNet2 Communication User Manual Module A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com SOLUTIONS Page 2 AN X DCSNet2 November 2011 Because of the variety of uses for the products described in this publication those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements including any applicable laws regulations codes and standards In no event will Quest Technical Solutions be responsible or liable for indirect or consequential damage resulting from the use or application of these products Any illustrations charts sample programs and layout examples shown in this publication are intended solely for purposes of example Since there are many variables and requirements associated with any particular installation Quest Technical Solutions does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Throughout this manual we use notes to make you aware of safety considerations Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss These warnings help to WARNING e identify a hazard e avoid the hazard recognize the
15. Configuration kernel version ProdRev Production kernel version HwRev Hardware version FirmwRev Firmware release version depends on current operating mode Status see below Vendorld Vendor ID ProdId Product ID IpAddrStr IP address assigned using Utilities AN X IP Configuration HostName name assigned using Utilities AN X IP Configuration In boot mode FirmwRev Vendor ID and Product ID and not valid and IpAddrStr and HostName are not shown Read Kernel Parameters The Utilities Read Kernel Parameters command displays various communications parameters for the currently selected AN X This command resets the AN X You will be warned and given the opportunity to cancel the command AL SoLuTIONS A product of Quest Technical Solutions Sold and Supported by F 3 ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 41 Local Area Connection 2 0x2 00 Oc 1a 00 00 0a 192 168 0 10 Anxinit Configuration Utilities Edit View Help x AN E Kernel Parameters console ttySO ip 192 168 0 10 192 168 0 1 192 168 0 1 255 255 255 0 ANXDCSNet eth0 none For Help press F1 The Utilities Read Kernel Parameters command leaves the AN X running the boot code Use the Utilities Restart AN X command to restart the AN X in production mode Run Config Mode The Utilities Run Config Mode command is used to restart the currently selected AN X in configuration mode
16. Connection Tab You display the Module Properties dialog by right clicking on any of the individual connections slots while online with RSLogix 5000 This may help diagnosing some problems especially connection errors The following information is based on version 12 00 of RSLogix 5000 although the same information is available in later versions If there is a problem with the connection to a module it is shown with a yellow triangle in the network tree The parameters should match what you set when you configured the module The Inhibit Module checkbox inhibits the module It should not be checked for normal operation The Major Fault on Controller if Connection Fails While in Run Mode checkbox causes the module to fault the processor if the connection between the ControlLogix processor and the module fails If there are any problems connecting to the module there will be an error message in the module fault area A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 36 AN X DCSNet2 Anxlnit Log AL SoLuTIONS November 2011 Using Anxlinit AnxInit is a 32 bit Windows application supplied with AN X to perform the following functions e Locate and identify AN X modules on the Ethernet network e Select a specific AN X for configuration e Set the IP address and other network parameters for an AN X e Res
17. Help Found 1 AN X device s oo000000a Pr eas MAC 00 0c 18 00 00 0a 192 168 ANxOODDOa For Help press F1 If AN X does not find a DHCP server within about three minutes of starting up it reverts to a temporary static IP address of 192 168 0 41 If A product of Quest Technical Solutions Bed os Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM eA SOLUTIONS Page 8 AN X DCSNet2 IMPORTANT IMPORTANT IMPORTANT AL SoLuTIONS November 2011 AN X is using this temporary IP address it repeatedly flashes the SYS LED three times followed by a pause Use this temporary IP address only for initial setup of AN X AN X will not function for its intended purpose at the temporary IP address If you are using multiple AN X modules configure one at a time especially if there is no DHCP server on the network since they will all revert to the same temporary IP address when they fail to find a DHCP server If you are connecting AN X to an existing Ethernet network consult the network administrator to obtain a static IP address for AN X and to obtain other information about how you should configure AN X The AN X must be on the local Ethernet same subnet as the computer when you set its IP address You configure the Ethernet properties using the Windows utility AnxInit supplied with AN X You can also set the IP address through the web interface Re
18. If you are required by technical support to examine files on the AN X select Administration Browse File System A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 55 ars AN X DCSNet2 Web Interf e C fi http 192 168 1 12 v Automation Network v Log Files Restricted Access v Administration password ay Submit Technical support will provide the password and supply detailed information on any further steps AN X IP Configuration You can change the AN X IP configuration from the web interface This requires that you already know the currect IP address and can use it to access the web interface Select Administration AN X IP Configuration A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 56 AN X DCSNet2 November 2011 v Automation Network AN X p Config u ration v Log Files v Administration DHCP Static AN X Hostname CSnet2 AN X IP Address 92 168 1 12 NET Mask 255 255 255 0 Gateway Address 192 168 1 1 SUBMIT You can configure the AN X to use DHCP or to use a static IP address Click SUBMIT to set the parameters When prompted click CONTINUE to reboot the AN X with the new parameters Archive Configuration You can archive all the current AN X configuration files and log files from
19. Init displays a list of the AN X modules it finds showing their MAC IDs IP addresses and host names This command is useful for determining IP addresses when they have been set by a DHCP server or for confirming that an AN X is accessible I Local Area Connection 0x10003 00 Oc 1a 00 01 0d 192 168 1 12 Anxinit E BR Configuration Utilities Edit View Help device s 0000010d Ethernet MAC 00 Oc 1a 00 01 0d 192 168 1 12 DCSnet 2 For Help press F1 A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 38 AN X DCSNet2 November 2011 Selecting an AN X Before you can perform an operation on an AN X you must select it Choose Utilities Select An AN X to select a specific AN X Set Ethernet amp IP Address Adapter Local Area Connection 2 Ethernet MAC Address 00 0c 1 a 00 00 0a IP ddress 192 168 0 10 From the Adapter list select the network adapter that connects to the Ethernet network that contains the AN X In the Ethernet MAC Address field enter the MAC Address of the AN X you wish to select It can be found on the AN X label or using the Locate All AN X Modules command The format is as shown above six pairs of hexadecimal digits separated by hyphens In the JP Address field enter the Ethernet IP address of the AN X you wish to select It can be found using the Locate All AN X Mod
20. Logix processor with RPIs from 5 to 750 ms Refer to page 22 for details The AN X DCSNet module has a web interface for configuration of DCSNet operation and for monitoring operation and data You can communicate with the module using any standard web browser such as Internet Explorer The module firmware can be updated over Ethernet using the Windows utility supplied Refer to page 61 for details AN X DCSNet2 Page 3 Hardware Features The module has e LEDs to indicate the status of the connection to the Ethernet its own internal state and the connection to the DCS network e an Ethernet connector e a9 pin D shell connector to connect to the DCS network a power connector A watchdog timer is implemented in the module s hardware If the firmware does not kick the watchdog within the timeout period the watchdog times out and places the module into a safe fatal failure state A jabber inhibit timer is implemented in the module s hardware If the network transmitter is on longer than 150 of the longest network frame time the transmitter is forced off and the module is placed into a safe fatal failure state Package Contents e AN X DCSNet module e CD containing software and documentation Other Requirements To use the AN X DCSNet with the AutoMax Programming Executive requires e version 3 9A or 4 3A or above of the programming executive e version 3 1 0 4 or above of the Virtual Device Driver A produ
21. Power consumption internally is 300 mA 12VDC or 150 mA 24VDC The part number for the power connector is Phoenix MSTB 2 5 3 ST 5 08 Contact us if you need a suitable wall adapter DCSNet Cabling and Termination Use a DCSNet drop cable 612574 36R or 612403 036R and passive tap M N 57C380 to connect the module to the coaxial network cable The drop cable is a 3 foot long multiconductor cable with 9 pin D shell connectors at each end Connect one end to the connector on the module and the other end to the passive tap A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 6 AN X DCSNet2 Ethernet Cabling Software Installation AL SoLuTIONS November 2011 The passive tap has two BNC connectors for connection to the coaxial cables and terminating loads The network coaxial cable must be terminated with 75 ohm terminating loads attached to the taps at the physical ends of the network There should be two and only two terminators on the network The DCS network cable can be RG 59 U or RG 11 U AN X has a standard RJ 45 connector for connecting to Ethernet If you are connecting AN X to an existing network through a router or switch use a standard Ethernet cable If you are connecting a computer or PLC directly to an AN X use a crossover cable You must uninstall any previous version of the software
22. Utilities Select An AN X command Firmware files have extension bin Firmware Update Wizard Select the Configuration Firmware Update command to start the firmware update wizard Step 1 In step 1 you identify the AN X you are configuring A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 43 Step 1 AN X Selection Select this computer s Ethernet adapter that s on the same Ethernet subnet as the AN module you want to configure you may only have one Ethernet adapter in your computer Local Area Connection 2 v Enter the Ethernet MAC Address of the AN xX module you want to configure You can get this from the label on the AN lt module or by selecting Utilities Locate All AN x Modules if the module s current IP address is on the same subnet 00 0c 1 a 00 00 0a Enter the IP address on the local subnet that you intend the AN module to use 192 168 0 10 1 Select the Ethernet adapter that s connected to the AN X In most cases there will be just one Ethernet adapter in the computer The AN X must be on the same subnet as the computer 2 Enter the MAC address of the AN X you are updating This is printed on the AN X label It consists of six pairs of hexadecimal digits separated by hyphens In the example above it s 00 Oc 1a 00 00 0a If the AN X is already onli
23. X DCSNet2 Log Files System Error Log System Info Log ControlLogix Log View All Logs Administration Menu Browse File System AL SoLuTIONS November 2011 AN X maintains various logs to record diagnostic and error messages Use the Log Files menu in the web interface to view these logs The System Error log records errors that occur during AN X operation This log is normally empty The System Info Log records informational messages during startup and normal operation The ControlLogix Log records messages from the application that is responsible for scheduled communication with a ControlLogix processor These messages include normal startup messages messages about problems with the configuration file and runtime errors such as timeouts If there are problems with scheduled connections to the AN X or with unscheduled messages to the AN X this log may provide further information on the cause of the problem If the log overflows AN X closes the log file enetip 0 and opens a second log file enetip 1 1 and continues to alternate between the two log files as each one fills up Use View All Logs to view both log files Use View All Logs to list and view all the AN X logs To view a log file double click on the file name The Administration Menu is used to set the AN X IP address and to view and edit files on AN X The file edit function is password protected and is used only for AN X technical support
24. age 62 AN X DCSNet2 CHNICAL Satorions November 2011 Specifications Parameter Specification Function Bridge between Ethernet and AutoMax DCS network Typical Power Consumption 300 mA 12 VDC or 150 mA 24 VDC Maximum Power dissipation 3 6W Environmental Conditions Operational Temperature Storage Temperature 0 50 C 32 122 F 40 to 85 C 40 to 185 F Relative Humidity 5 95 without condensation Sold and Supported by A product of Quest Technical Solutions 58 gt 3 2s ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 63 Support How to Contact Us Sales and Support Sales and Technical Support for this product are provided by ProSoft Technology Contact our worldwide Sales or Technical Support teams directly by phone or email Asia Pacific 603 7724 2080 asiapc prosoft technology com Europe Middle East Africa 33 0 5 34 36 87 20 Europe prosoft technology com North America 1 661 716 5100 support prosoft technology com Latin America Sales only 1 281 298 9109 latinam prosoft technology com A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 64 AN X DCSNet2 November 2011 Warranty Quest Technical Solutions warrants its products to
25. an exchange scheduled data with a ControlLogix processor over Ethernet Refer to section Scheduled Data with a ControlLogix on page 22 for information of configuring scheduled data exchange Select Automation Network Configure ControlLogix Support in the web interface to upload the configuration AN X DCSNet2 Web Interf x lt C ff r htp 192 168 1 12 AN X DCSNet2 ControlLogix Configuration duled data communication configuration using Excel and save that file in csv format To apply this configuration to this SNet2 device use the form below to select the local file Use the upload button to apply this configuration file EDtasiim Choose File Send To AN X v Administration Click the Choose File button and browse to find the configuration file Click the Send To AN X button to send the file to AN X Check the ControlLogix Log to determine if there have been any errors with the download View Configuration Files Select View Configuration Files to view the ControlLogix configuration file A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AN X DCSNet2 Page 51 ars AN X DCSNet2 Web Interf gt e C ff r hitp 192 168 1 12 AN X DCSNet2 Configuration Viewing View Configuration Files View Active Configuration Monitor DCSh Click on the links to view the files using the application that is associated with CSV fi
26. ating correctly Solid green No other drops Yellow Network error Flashes red DCS Slave All drops operating correctly Solid green No other drops Solid red Network error Flashes red DCS Diagnostic Counters AN X maintains standard DCS drop 0 diagnostic counters Use Automation Network Monitor DCSNet in the web interface to view the diagnostic counters The counters are Register Meaning 4 7 Drop status table 12 Local station s drop number 14 Messages received 15 Receive timeouts 16 CRC errors 17 Overrun errors 18 Abort errors 19 Messages transmitted 20 Local station s drop depth eA Solutions A product of Quest Technical Solutions E o Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 60 AN X DCSNet2 November 2011 In the drop status table register 4 contains status for drops 0 to 15 bit 0 corresponds to drop 0 the master bit 1 corresponds to drop 1 and so on Register 5 contains the status of drops 16 to 31 register 6 contains the status of drops 32 to 47 and register 7 contains the status of drops 48 to 55 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SoLuTIONS AN X DCSNet2 Page 61 Updating the Firmware The AN X operating software consists of several parts e boot code runs at startup e configu
27. be free from defects in workmanship or material under normal use and service for three years after date of shipment Quest Technical Solutions will repair or replace without charge any equipment found to be defective during the warranty period Final determination of the nature and responsibility for defective or damaged equipment will be made by Quest Technical Solutions personnel All warranties hereunder are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without Quest Technical Solutions approval or which have been subjected to accident improper maintenance installation or application or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables nor to any damage resulting from battery leakage In all cases Quest Technical Solutions responsibility and liability under this warranty shall be limited to the cost of the equipment The purchaser must obtain shipping instructions for the prepaid return of any item under this Warranty provision and compliance with such instruction shall be a condition of this warranty Except for the express warranty stated above Quest Technical Solutions disclaims all warranties with regard to the products sold hereunder including all implied warranties of merchantability and fitness and the express warranties stated
28. consequences Identifies information that is especially important for successful application and understanding of the product IMPORTANT Identifies information that explains the best way to use the me AN X DCSNet2 Microsoft is a registered trademark of Microsoft Corporation Windows Windows XP Windows Vista and Windows 7 are trademarks of Microsoft Corporation ControlLogix RSLinx and RSLogix 5000 are trademarks of the Allen Bradley Company Inc A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SoLuTIONS AN X DCSNET2 MODULE OVERVIEW Hardware Features Package Contents Other Requirements Modes of Operation INSTALLATION Prevent Electrostatic Discharge Power DCSNet Cabling and Termination Ethernet Cabling Software Installation ETHERNET CONFIGURATION Ethernet Configuration Example Standalone Computer Reconfiguring an AN X from an Unknown State DCSNET CONFIGURATION USING THE AUTOMAX PROGRAMMING SOFTWARE Requirements Installing and Configuring the VDD Configuring the Programming Software Multiple Programmer Access Connecting to a Different AN X SCHEDULED DATA WITH A CONTROLLOGIX Requirements 20 21 22 23 Page 4 AN X DCSNet2 Reference Configuring AN X in RSLogix 5000 Exclusive Owner Connection Input Only Connection Mapping the DCS Data ControlLogix Name ControlLogix Prefix I O Data Sample File
29. consists of the keyword ClxName a comma and the name you gave the module when you configured in in RSLogix 5000 Example ClxName ANX The ControlLogix name is used in the address part of the alias It can be up to 40 characters long ControlLogix Prefix The second line in the file is the ControlLogix prefix used to create the name part of the alias The first field contains the keyword ClxPrefix The second field contains text that prefixes the alias names created for the mapped data The prefix can be up to 33 characters long A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 30 AN X DCSNet2 1 0 Data AL SoLuTIONS November 2011 The ClxPrefix can be used to distinguish between AN X modules when a ControlLogix processor communicates with more than one AN X Use a different prefix for each AN X Example ClxPrefix ANX2 Each scheduled connection to the AN X begins with a line that consists of the keyword ClxSlot followed by a comma and then a number from 0 to 15 Example ClxSlot 0 This is followed by mappings of input and output data for that connection Scheduled outputs from the ControlLogix processor for the connection begin with a line with just the keyword DataOutput Scheduled inputs to the ControlLogix processor for the connection begin with a line with just the keyword DataInput
30. ct of Quest Technical Solutions E o Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 4 AN X DCSNet2 Modes of Operation AL SoLuTIONS November 2011 To exchange scheduled data with a ControlLogix processor over Ethernet requires version 12 or above of RSLogix 5000 e version 12 or above of the ControlLogix firmware e 100 Mbit second Ethernet network and hardware ENBT There are three AN X modes of operation Boot mode The AN X is running its low level startup firmware e Configuration mode This is the mode when you are updating the firmware in the AN X e Production mode This is the normal runtime mode of operation A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 5 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge Electrostatic discharge can damage integrated circuits or semiconductors Follow these guidelines when you handle the module WARNING e Touch a grounded object to discharge static potential e Do not touch the connector pins Power AN X requires a DC power input of anywhere from 12 to 24 VDC Left to right the pins on the power connector are chassis ground negative voltage and positive voltage GND The chassis ground should be connected
31. dress using the Utilities Locate All AN X Modules command 3 Enter the IP address you intend the AN X to use Step 2 In step 2 you choose a method of restarting AN X to put it in boot mode A product of Quest Technical Solutions Bed ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 10 AN X DCSNet2 November 2011 Step 2 Cycle Power or Reboot Command In order to configure the IP address or update the module s firmware the module must be be set to a specific mode There are two ways to do this 1 Cycle power on the AN X Module This is the preferred method but the AN module must be nearby If you choose this option POWER OFF the 4N module and click on the Next button C 2 Send a command on Ethernet that restarts the AN module This method is more convenient if the module is not nearby If you choose this option make sure the AN module is powered ON and fully up and running then click on the Next button lt lt Back The preferred method is to cycle power on the AN X Select the first option on the screen power off the AN X and click the Next gt gt button The second method useful if the AN X in not easily accessible is to send it a command over Ethernet The AN X must be powered on and completely running for this method to work For example if this is the first time you are configuring a new AN X allow sufficient time for it to acquire an
32. drops Run The ControlLogix connection run idle header can be mapped to an output register The form of this mapping is Run drop register The value is 1 if the ControlLogix is in run mode and 0 if it is in program mode Example Run 0 32 In DCS master or slave mode the register must be writeable by the AN X Connection Statistics The module maintains statistics for each exclusive owner scheduled connection There are 10 words of data for each connection Offset Description 0 Average time for last 100 CLX gt AN X updates 1 Minimum time for last 100 CLX gt AN X updates 2 Maximum time for last 100 CLX gt AN X updates 3 Maximum CLX gt AN X time since connection opened 4 Reserved 5 Average time for last 100 AN X gt CLX updates 6 Minimum time for last 100 AN X gt CLX updates 7 Maximum time for last 100 AN X gt CLX updates 8 Maximum AN X gt CLX time since connection opened 9 Reserved A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM eA Solutions Page 32 AN X DCSNet2 November 2011 The units for the times are 0 1 milliseconds A value of 87 means 8 7 ms To map the statistics for a given connection include a line with the keyword ConnStatsn where n is the connection number from 0 to 15 in the input section of a connection Examples ConnStats
33. dule DCS2master Connection Parameters Assembly Instance Size Name AnwSlotO Input 250 16 bit Description Output Configuration 4 Comm Format Input Data INT IPON Slot 0 V Open Module Properties i Cancel Help Set the parameters as shown Set the Comm Format to Input Data INT Set the Slot to 0 for the first connection 1 for the second connection and so on 3 Set the RPI for each connection to match the RPI of the exclusive owner connection Ensure that any check box that refers to Unicast connections is P T T IMPORTANT checked A product of Quest Technical Solutions Bd oi Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER AL PROGRAM SOLUTIONS AN X DCSNet2 Page 29 E Module Properties DCS2master 0 1756 MODULE 1 1 General Connection Module Info Backplane Requested Packet Interval RPI 50 ms 0 2 750 0 ms Inhibit Module I Major Fault On Controller If Connection Fails While in Run Mode Module Fault Status Offline i Cancel Help Mapping the DCS Data You define the DCS data that is exchanged between the AN X and the ControlLogix processor in a comma delimited text file which can be created using a spreadsheet such as Excel or using a text editor ControlLogix Name The first line in the file contains the module name used to create aliases that can be imported into RSLogix 5000 It
34. e firmware you must reconfigure the AN X and restore e DCS drop number and depth e ControlLogix configuration AN X to AN X configuration Patch Firmware The Utilities Patch Firmware command applies small patches to the firmware running on the AN X These patch files files have extension pch A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 47 Look in DCSNet e ex Ee a anxamxdes v1 6 2 pch File name Janxamudes v1 6 2 pch Files of type jars Firmware Patch File pch Cancel Open as read only This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command You do not have to reconfigure the AN X after applying a patch All configuration information will be left intact When the patch has been applied AnxInit restarts the AN X in production mode If you cancel at the filename dialog the AN X has already been reset and is in configuration mode Use the Utilities Restart AN X command to restart it in production mode A product of Quest Technical Solutions ED 5 Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 48 AN X DCSNet2 November 2011 Using the Web Interface The AN X module contains a webserver capable of communicating w
35. e times followed by a pause repeatedly Run AnxInit Select Utilities Locate All AN X Modules and confirm that the AN X is found I Local Area Connection 2 0x2 00 Oc 1a 00 00 0a 192 168 0 10 Anxinit BR Configuration Utilities Edit View Help x we device s 0000000a Ethernet MAC 00 0c 18 00 00 0a iM alfa elal ANXO0000a For Help press F1 A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 15 Select Utilities Select An AN X and enter the MAC Address and IP address Set Ethernet amp IP Address Adapter Local Area Connection 2 Ethernet MAC Address 00 0c 1 a 00 00 0a IP ddress 192 168 0 41 oen Click OK to accept the setting Select Utilities AN X IP Configuration AN X TCP IP Configuration Enter the IP configuration you want the previously selected AN lt module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN module but you don t need to have a device at that address Host Name ANXDCSNet Obtain an IP address automatically DHCP Use the following Settings IPAddress 192 168 0 10 Subnet mask 255 255 255 O Default gateway 192 168 0 1 Cancel Enter an IP Address In this case we chose 192 168 0 10 Enter the same Subnet mask and Default gateway that yo
36. em and software to indicate the state of operations and errors It should be used in conjunction with the logs to locate the cause of problems In the following red 3 means three red flashes followed by a pause and so on SYS LED State Possible cause Red 2 AN X is in config mode Red 3 DHCP configuration failed Red 4 Fatal application error check logs for cause Red 5 Application memory access violation check logs Red 6 Application failed illegal instruction check logs Red 7 Application crashed unknown cause check logs Fast red flash Reconfiguration set drop number and depth failed Configuration of ControlLogix support failed Single red flash ControlLogix scheduled data or unscheduled messaging addressing or connection problem Slow red flash script or application problem during startup A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS At startup the SYS LED sequence is e boot code starts fast flashing red e boot code loads a kernel solid red e if the configuration kernel is loaded 2 red flashes followed by a pause e if the production kernel loads with no errors solid green NET LED DCS Network Status The NET LED indicates the status of the DCS network connection AN X DCSNet2 Page 59 DCS Master All drops oper
37. em uses the source of programming messages direct connection to the serial port or drop number on DCSNet to distinguish between programmers It uses the identity of each programmer to manage levels of access None Data Task and to return requests for data to the programming devices The AutoMax operating system controls the operations that programming device can perform depending on their access level AL Solutions A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ote ee Q PROSOFT PARTNER PROGRAM AN X DCSNet2 Page 21 If multiple copies of the Programming Executive attempt to program an AutoMax through the same AN X DCSNet the AutoMax sees them as a single user since they are all connected using the drop number of the AN X DCSNet This causes the following anomalous behavior in the programming devices e variables I O and ladder logic may be displayed incorrectly since the same data is sent to all devices connected to the same AN X DCSNet each Programming Executive connected through the same AN X DCSNet receives the same access level If you change the access level on one the AutoMax operating system changes to the same level on all of them This defeats the built in access management in the AutoMax Each copy of the Programming Executive should communicate with the AutoMax using a different AN X DCSNet to ensure that t
38. er Windows Vista The following instructions assume that e AN X has been configured and is active on the Ethernet network e AN X has been connected to the DCS network e the AN X DCS drop number and drop depth have been assigned see page 48 To use AN X DCSNet with the AutoMax Programming Executive you must complete the following steps 1 Install and configure the Virtual Device Driver VDD 2 Configure the programming software to use AN X Requirements Virtual Device Driver VDD version 3 1 0 4 or above available on the AN X distribution CD AutoMax Programming Executive 3 9 or 4 3 or above Installing and Configuring the VDD 1 Install the virtual device driver Insert the AN X distribution CD that contains the Virtual Device Driver and install it 2 Run the Control Panel Applet Start Control Panel QTS PC Link Card Configuration and set the Port Address and Memory Address You can leave them at their default values Check Enable AN X DCSNet Link 4 Enter the IP address of the AN X in the AN X IP Address field If you do not know the IP address use Utilities Locate All AN X Modules in AnxInit see page 37 to find it 5 Click OK A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X DCSNet2 Page 19 QTS AutoMax PC Link CFG Card Name Card Resources PortAddress asl v Memory Address
39. fer to page 55 Use the Configuration AN X IP Settings command to start the AN X IP configuration wizard which takes you step by step through the IP configuration process Step 1 In step 1 you identify the AN X you are configuring A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 9 Step 1 AN X Selection Select this computer s Ethernet adapter that s on the same Ethernet subnet as the AN module you want to configure you may only have one Ethernet adapter in your computer Local Area Connection 2 v Enter the Ethernet MAC Address of the AN xX module you want to configure You can get this from the label on the AN lt module or by selecting Utilities Locate All AN Modules if the module s current IP address is on the same subnet 00 0c 1 a 00 00 0a Enter the IP address on the local subnet that you intend the AN module to use 192 168 0 10 1 Select the Ethernet adapter that s connected to the AN X In most cases there will be just one Ethernet adapter in the computer The AN X must be on the same subnet as the computer 2 Enter the MAC address of the AN X you are configuring This is printed on the AN X label It consists of six pairs of hexadecimal digits separated by hyphens In the example above it s 00 Oc 1a 00 00 0a If the AN X is already online you can obtain its MAC ad
40. gisters 32 to 39 on drop 0 broadcast data and registers 32 to 63 on drops 1 to 55 If the AN X is a DCS slave allowed output data includes registers 0 to 31 on any drops 1 to 55 that are included in the AN X drop number and drop depth The AN X sends input data to the ControlLogix The configuration file defines how DCSnet data is mapped to ControlLogix input data There are no restrictions on which DCS registers can be mapped to ControlLogix input data In addition you can also map connection statistics to ControlLogix inputs You define data mappings in a comma separated text file and use the AN X web interface to send the mapping file to the AN X Connections There are two possible types of scheduled connections from the ControlLogix processor to the AN X DCSNet e Exclusive owner connection which contains input and output data e Input only connection which contains input data Only the exclusive owner connection can write data to AN X and to DCSNet There can be only one exclusive owner connection to an AN X module In general you should try to keep the number of connections small There is significant overhead in opening and maintaining each connection Configuration To configure the scheduled data exchange 1 Configure AN X in RSLogix 5000 A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNe
41. gned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically ing IP address IP address 192 168 0 10 Subnet mask 255 25 25 0 Default gateway 192 168 0 1 Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server Advanced Cancel A product of Quest Technical Solutions gt Sold and Supported by ProSoft Technology Inc PROSOFT Guest www prosoft technology com PARTNER PROGRAM Tei SOLUTIONS Page 14 AN X DCSNet2 November 2011 In this example we will assign the computer an IP address of 192 168 0 10 Set the Subnet mask to 255 255 255 0 standard mask for the Class C network address of 192 168 0 x Set the Default gateway to 192 168 0 1 this address does not exist on the Ethernet network but AN X requires a valid default gateway entry Click OK to accept the settings Connect the computer to AN X using the crossover cable If this is the first time you have used the AN X module it will look for a DHCP server on the network It waits about three minutes then reverts to a default IP address of 192 168 0 41 Power up the AN X and wait for the search for a DHCP server to time out When the search for a DHCP server times out AN X will flash the SYS LED red thre
42. gure ControlLogix Support Browse or type in the configuration file name Click Send To AN X Mo o oe The web interface displays the result of the upload either success or an error message To see further details select Log Files ControlLogix Log see page 54 and check for error messages A product of Quest Technical Solutions O gt Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 34 AN X DCSNet2 November 2011 Viewing the Current Configuration To view the configuration in an AN X module access the AN X using the web interface and select Automation Network View Configuration Files Click on the link AN X DCSNet ControlLogix Ethernet IP Configuration File To save the configuration to a file on your computer right click on the link and save the target to a file Error Log Errors that occur during configuration of scheduled data or during operation of scheduled data or unscheduled messaging are logged in the AN X You can view the log using the AN X web interface Select Log Files ControlLogix Log to view the log ars AN X DCSNet2 Web Interf e fi r hitp 192 168 1 12 gt D Bs Google e Astronomy Picture of G38 BBC NEWS News Fro Kitchener Waterloo Current Readings for KWwondermap Other bookmarks a 2i File var log enetip 0 Length 164 bytes Select new file F 00 00 000 000 AN X DCSNet Ethe
43. he AutoMax operating system can properly detect them as separate copies of the Programming Executive Multiple copies of the Programming Executive should NOT be connected through the same AN X DCSNet Each programmer should use a separate AN X Connecting to a Different AN X If you have more than one AN X on the Ethernet network each connected to a different DCS network to change the AN X your programming software is using run the Control Panel Applet Start Control Panel QTS PC Link Card Configuration and change the IP address in the AN X IP Address field If you do not know the IP address use Utilities Locate All AN X Modules in AnxInit see page 37 to find it A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 22 AN X DCSNet2 AL SoLuTIONS November 2011 Scheduled Data with a ControlLogix AN X DCSNet2 exchanges scheduled data with a ControlLogix processor It supports up to 16 scheduled connections up to 248 registers of ControlLogix output data per connection e up to 250 registers of ControlLogix input data per connection The ControlLogix processor sends its output data to the AN X DCSNet2 and the AN X sends it out on the DCS network You create a configuration file to define how the ControlLogix data is mapped to DCSNet registers If the AN X is a DCS master allowed output data includes re
44. herein are in lieu of all obligations or liabilities on the part of Quest Technical Solutions for damages including but not limited to consequential damages arising out of or in connection with the use or performance of the Product A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SoLuTIONS
45. ice This only applies to slave mode Drop Depth set the drop depth of the AN X DCSNet2 device This only applies to slave mode The left pane contains commands Click on the arrows at the left of the main headings to expand or contract the sections The contents of the right pane depend on the current command being executed DCSNet Configuration Select Automation Network DCSNet Configuration to set the DCS drop number and depth A product of Quest Technical Solutions Ji Sold and Supported by i j 7 ProSoft Technology Inc www prosoft technology com yea SOLUTIONS AN X DCSNet2 Page 49 AN X DCSNet2 Configuration Master Slave Drop Number Drop Depth v Log Files v Administration AN X DCSNet can be used as a DCS master or slave Check Master or Slave to select which one you want If the AN X DCSNet is a DCS slave enter the Drop Number and Drop Depth These entries are ignored if the AN X is a DCS master The default AN X configuration is DCS slave drop 55 depth 1 Click the SUBMIT button to send the values to AN X If you are using ControlLogix Support check the logs since the new DCS parameters may be incompatible with the current configuration A product of Quest Technical Solutions a Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 50 AN X DCSNet2 November 2011 Configure ControlLogix Support AN X c
46. iguration dialog appears AN X TCP IP Configuration Enter the IP configuration you want the previously selected AN module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN X module but you don t need to have a device at that address Host Name ANXDCSNet Obtain an IP address automatically DHCP Use the following Settings IP Address 192 168 O0 10 Subnet mask 255 255 255 0 Default gateway 192 168 0 A product of Quest Technical Solutions a o Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 12 AN X DCSNet2 November 2011 Enter a Host Name for the AN X This name is used internally by AN X and may be used to identify the AN X if you have a DNS server on your network The name can be from 1 to 31 characters long To configure the AN X to obtain its IP address from a DHCP server on the network select Obtain an IP address automatically DHCP To configure the AN X to use a static IP address select Use the following Settings and enter e the desired IP address for the AN X e the Subnet mask for the AN X e the default gateway for your network You must enter a valid default gateway address even if there is no device at the gateway address on the network Click OK to complete the configuration If you Cancel the Configuration AN X IP Settings command AN X is left running
47. ith standard web browsers such as Internet Explorer The web interface is used for e setting the DCSNet configuration drop number and depth e uploading ControlLogix and AN X to AN X configuration files monitoring DCS data e viewing AN X logs To use the web interface you need to know the IP address of the AN X Use the Utilities Locate All AN X Modules command in AnxInit to find all AN X modules on the Ethernet network To access the web interface start your web browser and type the AN X IP address where you normally enter web addresses in the browser Googe S x ars AN X DCSNet2 Web Inter x lt C fi r hitp 192 168 1 12 v Automation Network AN X DCSNet2 Ethernet Gateway Log Files v Administration Introduction This is the main configuration screen for the AN X DCSNet2 Ethernet gateway product Directions The main menu located on the left provides a list of options that can be configured using this web interface To see the sub menus for each item click on the down arrow icon beside each main option Menu Details Automation Network Contains all the option pages that pertain to the DCSNet network DCSNet Configuration This screen is used to configure the DCSNet options of the AN x DCSNet2 Ethernet gateway Specifically the following DCSNet options can be set Master Slave Mode use the AN X DCSNet2 device as a DCSNet master or slave Drop Number set the drop number of the AN X DCSNet2 dev
48. les Right click on the links to retrieve the files from AN X and store them on your computer View Active Configuration Select View Active Configuration to view the ControlLogix configuration file in the web browser A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 52 AN X DCSNet2 November 2011 DCSNet Configuration Config trolLogix ClxPrefix DCSmaster2 Y onfiguration Files View Active Configuration Monitor DC A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SOLUTIONS AN X DCSNet2 Page 53 Monitor DCS Data To use the web interface to view the current DCS network data on the AN X select Automation Network Monitor DCSNet DCSNet Configuration Configure ControlLogix Support View Configuration Files View Active Configuration Reg Num Value Monitor DC Log Files linistration To select the drop to be displayed type the drop number in the Drop Number field and click Submit To update the display click the Refresh Registers button Scroll the browser window to view all the data The values are shown in hexadecimal Beneath the data display is a summary of the drop 0 diagnostic register usage see page 59 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 54 AN
49. ly connection from a ControlLogix processor The ControlLogix processor will be able to read the same input data as the ControlLogix processor with the exclusive owner connection to the AN X DCSNET2 The data received will depend on the mappings in the AN X DCSNET2 To configure the input only connection to the AN X DCSNET2 in RSLogix 5000 1 Right click on the ControlLogix Ethernet module that will be communicating with the AN X and select Add Module Adda 1756 ENBT A module Set the Major Rev to 1 E Module Properties ENBT 16 1756 ENBT A 1 1 General Connection Module Info Port Configuration Port Diagnostics Backplane Type 1756 ENBT 4 1756 10 100 Mbps Ethernet Bridge Twisted Pair Media Vendor Allen Bradley Parent ENBT Nane DCS 2master Address Host Name Description PAddress 192 168 1 10 C Host Name Comm Format None X je Slot fis 4 Chassis Size f 7 Revision 1 e fi Electronic Keying Disable Keying v Status Offline Set the Slot to 16 Set the chassis size to 17 Set the Comm Format to None Set the IP address to match the AN X module Set Electronic Keying to Disable Keying 2 Add Generic modules for each required connection A product of Quest Technical Solutions ED oi Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 28 AN X DCSNet2 November 2011 New Module 1756 MODULE Generic 1756 Mo
50. ne you can obtain its MAC address using the Utilities Locate All AN X Modules command 3 Enter the IP address of the AN X you want to update Step 2 In step 2 you choose a method of restarting AN X to put it in config mode A product of Quest Technical Solutions Bed ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 44 AN X DCSNet2 November 2011 Step 2 Cycle Power or Reboot Command In order to configure the IP address or update the module s firmware the module must be be set to a specific mode There are two ways to do this 1 Cycle power on the AN X Module This is the preferred method but the AN module must be nearby If you choose this option POWER OFF the 4N module and click on the Next button C 2 Send a command on Ethernet that restarts the AN module This method is more convenient if the module is not nearby If you choose this option make sure the AN module is powered ON and fully up and running then click on the Next button lt lt Back The preferred method is to cycle power on the AN X Select the first option on the screen and click the Next gt gt button The second method useful if the AN X in not easily accessible is to send it a command over Ethernet The AN X must be powered on and completely running for this method to work For example if this is the first time you are configuring a new AN X allow sufficient time for it
51. puter or other device to a Reliance DCS network using Ethernet The module can act as a DCS master or a DCS slave As a DCS master the module Scans up to 55 slave drops e Transmits 8 words of broadcast data every 2 8 ms e Maintains standard DCS diagnostic counters As a DCS slave the module e Acts as any drop from 1 to 55 with drop depth from 1 to 55 It supports 32 words of input data and 32 words of output data per drop e Receives 8 words of broadcast data from the master every 2 8 ms e Monitors the input and output data on others drops on the network e Maintains standard DCS diagnostic counters You can use the AN X DCSNet module to communicate with an AutoMax processor using AutoMax Programming Executive 3 9A or 4 3A or above Refer to page 18 for details Note that AutoMax programming software access is not supported under Windows Vista The AN X DCSNet2 firmware differs from the standard AN X DCSNet firmware in that it supports up to 15 scheduled data connections to a ControlLogix processor whereas the standard firmware supports just one scheduled connection Use the AN X DCSNet2 firmware in applications where you have a large DCS network and want the data to update quickly The AN X DCSNet2 firmware does NOT support direct AN X to AN X communication over Ethernet If you need this function use the standard AN X DCSNet firmware The AN X DCSNet module supports exchanging scheduled data over Ethernet with a Control
52. ration kernel runs when you update firmware e production kernel runs in normal operation e application software for DCS communication scheduled communication with ControlLogix and unscheduled messaging and AN X to AN X communication The kernels are supplied in file with extension qtf and are updated using the AnxInit utility Run the command Utilities Update AN X Flash and select the file you wish to download Refer to page 41 for details Firmware files contain the application programs for AN X and have extension bin They are downloaded using the command Configuration Firmware Update or Utilities Update Firmware in AnxInit Refer to page 42 for details Occasionally individual patch files are released They have extension pch and are downloaded using the Utilities Patch Firmware command in AnxInit Refer to page 46 for details Reading Version Numbers To read the version numbers of the various software components Boot code AnxInit AN X Info Configuration kernel AnxInit AN X Info Production kernel AnxInit AN X Info Firmware AnxInit AN X Info version depends on current mode boot configuration or production ControlLogix scheduled Web interface ControlLogix Log communication and unscheduled messaging A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM eA Solutions P
53. rnet IP Server Version 4 2 12 00 01 370 728 init_socket 00 01 956 995 Init OK 19 41 126 391 SIGHUP Reloading Configuration l DCSNet Configuration Configure ControlLogix Support View Configuration Files 2 View Active Configuration Monitor DCSNet If the log overflows AN X closes the log file enetip 0 and opens a second log file enetip 1 and continues to alternate between the two log files as each one fills up Use View All Logs to view both log files Exporting Aliases from AN X AN X uses the Ethernet IP configuration to create aliases that can be imported into RSLogix 5000 Use these aliases in your RSLogix 5000 program to access the data on the AN X A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SOLUTIONS AN X DCSNet2 Page 35 In the web interface select Automation Network View Configuration Files There are two sets of files one for exclusive owner connections and one for input only connections To view the files click on either AN X DCSNET Ethernet IP ControlLogix Exclusive Owner Data Tags or AN X DCSNET Ethernet IP ControlLogix Input Only Data Tags To save the file to your computer right click on the link and select Save Target As To import the tags into RSLogix 5000 you must be offline Select Tools Import Tags and import the file Using RSLogix 5000 to Diagnose Problems General Tab
54. t the firmware file you want to download and click Open Look in lea Des gt m ex a anxamxdcs 1 6 5 bin File name Janxamxdes 1 6 5 bin G 3 Files of type jars Firmware File bin Cancel j F Open as read only Anxlnit transfers the firmware file and restarts the AN X After you run update the firmware you must reconfigure the AN X and restore DCS drop number and depth A product of Quest Technical Solutions E o Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 46 AN X DCSNet2 November 2011 e ControlLogix configuration Update Firmware Command The Utilities Update Firmware command updates all the firmware on an AN X you have previously selected using the Utilities Select An AN X command This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command If you cancel at the filename dialog the AN X has already been reset and is in configuration mode Use the Utilities Restart AN X command to restart it in production mode Click the Next gt gt button and select the firmware file you want to download and click Open Look in Des ef ey E anxamxdes 1 6 5 bin File name anxamsdes 1 6 5 bin p i Files of type fats Firmware File bin Cancel Open as read only AnxInit transfers the firmware file and restarts the AN X After you run update th
55. t2 Page 23 2 Map DCS data to the scheduled data and save the mappings as a comma separated variable CSV file 3 Send the configuration file to AN X Requirements e RSLogix 5000 version 12 or above e ControlLogix processor with firmware version 12 or above e 100 Mbit Ethernet network and ENBT modules We strongly recommend using Ethernet switches rather than hubs Reference Allen Bradley publication EtherNet IP Media Planning and Installation Manual publication ENET IN001A EN P Configuring AN X in RSLogix 5000 The AN X DCSnet2 emulates a 17 slot 1756 chassis with an ENBT A in slot 16 and generic modules in slots 0 to 15 Exclusive Owner Connection To configure the AN X DCSnet2 in RSLogix 5000 1 Right click on the ControlLogix Ethernet bridge module that will be communicating with the AN X and select Add Module Adda 1756 ENBT A module Set the Major Rev to 1 A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 24 AN X DCSNet2 November 2011 New Module Type 1756 ENBT 4 1756 10 100 Mbps Ethernet Bridge Twisted Pair Media Vendor Allen Bradley Parent LocalENBT ane ANXDCSNet m Address Host Name Description PAddress 192 168 1 12 Host Name i Comm Format None Slot 16 H Chassis Size fi Revision fi 7 j Electronic Keying Disable Keying V Open Module Properties i
56. tart an AN X e Display information about the selected AN X e Read the kernel parameters for the selected AN X e Update the flash low level firmware on the selected AN X e Update the firmware on the selected AN X e Patch the firmware on the selected AN X In addition it can be used to e clear the AnxInit log copy the contents of the log to the clipboard for use by another application This is often useful for technical support AnxInit logs messages in its main window These messages are often useful for determining the cause of errors or for technical support To clear the log select Edit ClearLog To copy the contents of the Log to the Windows clipboard so that they can be pasted into another application select Edit Copy A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X DCSNet2 Page 37 I Local Area Connection 0x10003 00 Oc 1a 00 01 0d 192 168 1 12 Anxinit E BR Configuration Utilities Edit View Help Bax nxInit Ready AN X Info 00 Oc 1a 00 01 0d 0000010d 0003 AutoMax 3 01 0007 3 02 0001 3 02 0001 1 01 0001 03 0001 Ox00000004 Production Mode OTS Inc AN ZX DCSNet2 Ethernet Gateway abs aaao ab abs DCSnet 2 For Help press F1 AN X Log Locating Available AN X Modules To locate all accessible AN X modules on the Ethernet network select Utilities Locate All AN X Modules Anx
57. to acquire an IP address from a DHCP server or to time out and use its default IP address about 3 minutes Select the second option on the screen and click the Next gt gt button Step 3 Wait for AN X to enter config mode While AnxInit is waiting the Next gt gt button will be disabled When AN X is in boot mode the Next gt gt button will be enabled A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X DCSNet2 Page 45 Step 3 Wait for Config Mode If you selected the Cycle Power option power ON the AN lt module now If you selected the Reset Command option a reset command has been sent to the AN module This program is now sending messages to the 4N module using the MAC address and IP address you entered previously These messages tell the AN module to enter into Config state in preparation for updating the firmware If the AN module enters Config mode successfully the Nest button below will be enabled so you can move on to the next step If the AN module has been powered ON for more than 60 seconds and the Next button is still disabled press the Back button confirm the MAC and IP addresses and check the Ethernet cabling If the AN X does not enter config mode within about 60 seconds return to the previous screens and check the entries Click the Next gt gt button and selec
58. u entered for the computer The default gateway address does not exist on the network but AN X requires that the field have a valid entry Click Finish to accept the settings Select Utilities Restart AN X to restart AN X with the new parameters When the AN X has restarted SYS LED is solid green select Utilities Locate All AN X Modules and confirm that the AN X is found with the new parameters A product of Quest Technical Solutions gt es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM eA SOLUTIONS Page 16 AN X DCSNet2 November 2011 I Local Area Connection 2 0x2 00 Oc 1a 00 00 0a 192 168 0 10 Anxinit EBK Configuration Utilities Edit View Help By x k device s 00000008 Ethernet MAC 00 0c 1a8 00 00 0a ele abfets a abla ANEDCSNet For Help press F1 Reconfiguring an AN X from an Unknown State It sometimes happens that an AN X has been previously configured with an IP address that causes it to be inaccessible on the current Ethernet network To reconfigure it to a known state run the command Configuration AN X IP Settings to start the AN X IP Configuration Wizard and reconfigure the AN X A product of Quest Technical Solutions so e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS le AN X DCSNet2 Web Interface v3 2 1 Mozilla Firefox AN X DCSNet2 Page
59. ules command The format is as shown above four decimal numbers each in the range 0 to 255 Both MAC address and IP address must match the settings on the AN X in order for communication to occur Click OK to select the AN X The title bar of AnxInit shows the MAC Address and IP Address of the currently selected AN X Set AN X IP Configuration Utilities AN X IP Configuration sets the AN X IP address and hostname The AN X must be on the local Ethernet to set its IP address First select the AN X using the Utilities Select An AN X command Next select Utilities AN X IP Configuration The AN X TCP IP Configuration dialog appears A product of Quest Technical Solutions b gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions AN X DCSNet2 Page 39 AN X TCP IP Configuration Enter the IP configuration you want the previously selected AN module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN module but you don t need to have a device at that address Host Name ANXDCSNet C Obtain an IP address automatically DHCP Use the following Settings IPAddress 192 168 0 10 Subnet mask 255 255 255 O Default gateway 192 168 0 1 Cancel Enter a Host Name for the AN X This name is used internally by AN X and may be used to identify the AN X if you have a DNS server on your

Download Pdf Manuals

image

Related Search

Related Contents

Sanyo DP42545 User's Manual  滅菌オオサキOBリネンセットⅡ  ブザー式けむねつタン (KRG-1D・CRG  Stoptech E Brake Install (revised)  ビスタカムiX 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file