Power Distribution Indicator

image

Contents

1. Watt meter 39 380VAC or 19 220VAC PI 485 E Multi Multi V Outdoor unit Address setup Start gt End 7C gt 7F 00 01 02 03 Indoor unit address setup Multi Multi V Outdoor unit 7C 7D 7E Indoor unit ET address setup CNU PQNFG14B0 amnya PC central controller 3K NOTE PI 485 must be connected for PDI with PDI PI 485 must be purchased separately A CAUTION When CNU power off or out of order with PC central controller the PDI can not distribute the power consumption Users Manual 9 Internal Wiring Diagram Minternal Wiring Diagram E Install the product as per the following wiring diagram OLA amp pecs Multi V Indoor unit PDI WHM PI 485 communications A B or E a MultV MultiV PLUS A B Z i Watt meter A gt A B gt B CN POWER CN_OUT FAN Li L o Lu E Lu x Z O The color and polarity of the communications line can differ from what s indicated on the PCB depending on the manufacturer of watt meter Black gt white gt e Turn on the power after connecting the product 10 Electricity Distribution Indicator Installation Installation 1 You must start the key operation within 10 minutes after turning on the power for setting options 2 When you press the Menu and Shift key at the same time the following option screen
2. LG Power Distribution Indicator Visit us at http www lgservice com OWNER S amp INSTALLATION MANUAL Models PQNUD1S00 IMPORTANT e Please read this user s manual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only e Please retain this user s manual for future reference after reading it thoroughly Power Distribution Indicator Owner s amp Installation Manual TABLE OF CONTENTS J FOR YOUR RECORDS Write the model and serial numbers here Cautions for safety 3 Model OVervieW a a es 6 Serial 7 You can find them on a label on the side of each unit Available Watt hour meter 7 Dealer s Name Wiring Diagram 0 10 Date Purchased E Staple your receipt to this page in the event you need Installation eee 11 to prove dale of purchase on to issue Warranhy How to set interface unit 17 How to set each Indoor Unit pP READ THIS MANUAL V e ener ee 1 teal E Inside you will find many helpful hints on how to use Installation Guide 20 and maintain your Power Distribution Indicator properly Just a little preventive care on your part can save you a Usage errr narnia eae 21 great deal of time and money over the life of your Power Distribution Indicator You ll find many answers to common problems
3. STBP What is standby power selection function Standby power refers to the electric power consumed by the product after the operation of the product is turned off It is the function of separately saving the power consumed when all heating and air conditioning indoor units are turned off 14 Electricity Distribution Indicator Installation J gt SHIFT Cm La LGAP 3 After setting the option press the Shift key to enter the remote reading service ID setup mode In case of selecting reading service ID in e This function is applicable to only korean marcket Domestic So skip this setting in the procedure for overseas marcket Press the SHIFT key When the first two digits flash use the s or t key to select the remote reading service ID by company CI TOPIA ID setup OUT DR ID CITOPIA XX OMNI SYS ID setup OUT DR ID OMNI SYS XXXX MICRONICS ID setup OUT DR ID MICRONIC XX LS IS ID setup OUT DR ID LSIS XXXX When setting the remote reading service ID enter the remote reading service ID assigned by the remote reading service company 4 After entering the remote reading service ID press the Shift key to enter the indoor address selection mode In case of the selecting Master Slave User s Manual 15 Installation Press the Shift key to enter the indoor selection mode MENU a v gt S
4. Center or to installation expert agency e Otherwise it may cause fire hazard electric shock explosion injury or damage Don t disassemble repair and modify the product at your will e Or else it may cause fire hazard and electric shock Users Manual 3 Cautions for safety Don t install it where rain falls on Don t install it in humid place e Otherwise it may cause product failure e Otherwise it may cause product failure E WHEN USING Don t change or extend electric supply wire at your will e Or else it may cause fire hazard and electric shock i Don t spill water into interior of the product e Otherwise it may cause electric shock and product failure Don t let there exist fire heat Don t use heat equipment near the product near the electricity supply line e Otherwise it may cause fire e Or else it may cause fire hazard hazard and electric shock Don t put heavy material upon Don t put heavy material electricity supply chord upon the product e Or else it may cause fire e Or else it may cause hazard and electric shock product trouble failure Always request to our Service Center or installation expert agency in such case as the product has been submerged under water e Or else it may cause fire hazard and electric shock Child or the old and the weak Don t give impact to the shall use it under custody of prod
5. Suppl power after completing the Wiring e Set the Power Distribution Indicator so as to fit the usage condition 20 Electricity Distribution Indicator Usage I Usage The distributed power consumption is based on current operating condition e Press the Menu key once to display the current power consumption e Consecutively press the Menu key to switch the screen e The PDI will operate normally after 3 minutes when all options are set 1 PWR distribution mode oloo o 10 TNT ere MENU A v gt SHIFT ha TS Sr 16 ic LGAP Initial Mode Press Menu key PWR Distribution Display Mode Press Menu key Press Menu key Accumulated PWR Display Mode Press Menu key Period Accumulated PWR Display Mode e It displays the current power consumption of each indoor unit Watt hour e When 1 2 indoor units are connected only 1 page is displayed e When 4 or more indoor units are connected press the Shift key to check the next page Total SUM Value XX XXXX xX PWR XX XXXX X Press Indoor 1 Value Shift key Indoor 2 Value Total SUM Value XX XXXX X xXX XXXX xX Indoor 3 Value Indoor 4 Value User s Manual 21 Usage e When selecting the option for classifying the stand by power the stand by power is displayed in the last page The stand by power page PWR Dist 00 0000 0 Stand by power 2 ACCUMPWR
6. distribution mode e It displays the accumulated power consumption of each indoor unit Kwh e When 1 2 indoor units are connected only 1 page is displayed e When 4 or more indoor units are connected press the Shift key to check the next page _ Total SUM Value Press Indoor 1 Value Shift key Indoor 2 Value Total SUM Value ACG PWR ce O2 X XXX XS eo Indoor 3 Value Indoor 4 Value e When selecting the option for classifying the stand by power the stand by power is displayed in the last page The stand by power page ACC PWR 00 0000 0 Stand by power 22 Electricity Distribution Indicator Usage 3 Period accumulated power distribution mode e It displays the power consumption of each indoor unit Kwh e When 1 2 indoor units are connected only 1 page is displayed e When 4 or more indoor units are connected press the Shift key to check the next page _ Total SUM Value Perid ACCM 0O Dees KX Press Indoor 1 Value Shift key Indoor 2 Value ae Total SUM Value REEERE E EEE Indoor 3 Value Indoor 4 Value e Press the A and W key at the same time for 3 seconds to clear the data e As the function for manual check when cleared after the check it displays the cumulated power from the clearing point e When classifying the stand by power it is shown after the last page The stand by power indication page Perid ACCM 00 0000 0 SIBIR 0
7. 000 0 Stand by power User s Manual 23 LG P No 3828A20820C Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference
8. Distribution Indicator Overview E Parts of a PDI a A OO N 6 1 Indicator LCD Display 2 Name Plate of each room 3 Menu Button 4 Up and Down Button 5 Right Shift Button 6 SHIFT Button for LCD Screen Change If Available Watt hour meter Local purchase e Use the digital watt meter which send the pulse signal depending on the power consumption e Use watt meter of 1W pulse 2W pulse 4W pulse 6W pulse 8W pulse or 10W pulse pulse width 40 400 msec User s Manual 7 Wiring Diagram Wiring Diagram E Independent operation of PDI Connect the product as shown in the below connection diagram 1 MultiV MultiV PLUS 16 indoor units MAX 30 380VAC or Watt meter 1 220VAC Ea many MultiV MultiV PLUS Outdoor unit 00 01 02 03 Indoor unit address setup 2 MPS multi Product MultiV PLUS 48 indoor units MAX 30 380VAC or Watt meter 19 220VAC 7 cS Address setup Start gt End 00 gt 03 MPS multi Outdoor unit 00 01 02 03 Indoor unit address setup NOTE In connecting MPS product PI 485 must be connected for PDI P 485 must be purchased separately 8 Electricity Distribution Indicator Wiring Diagram E Operation with PC Central controller Connect the product as shown in the below connection diagram Address setup Start gt End 00 gt 03
9. HIU Start gt End w Q JA Oo 00 e You can select the option for indoor address selection mode only when Master Slave is selected e You can distribute the using power to maximum of 48 indoor units When showing the stand by power maximum of 47 indoor units Ex 1 Distribution of using power to 64 indoor units central control address 00 2F Start gt End 00 gt 2F NOTE 2 When operating in connection to the PC central controller the range of the indoor address setup Start End on the power indicator is from 00 to 7F The Start and End address of the power indicator refers to the first and last address of the indoor unit group Ex Indoor address 72 73 74 75 u Start address 72 End address 75 Press the Menu key to save the remote reading service ID and return to the initial screen 16 Electricity Distribution Indicator How to set Interface unit I How to set Interface unit PI 485 Selection air Selection conditioner type network type ON KSDO4H Pil li MULTIV pLus amp MPS MULTI Products Configuration Methods ON KSDO4H mi o E E ON KSDO4H a A 5l F 1 4 ON ALL OFF munriV pws amp MPS Inverter Product Central Controller m 2 4 ON ALL OFF MPS Multi Standard Product Central Controller ACAUTION
10. Wrong Products Configuration can lead to malfunctioning User s Manual 17 How to set each Indoor Unit I How to set each Indoor Unit E Using wired remote controller 1 Press the Program amp AUTO SWING OPERATION SETTENP FAN SPEED SUB FUNCTION F f a IG Se nc ey Set Cir keys at the same o time 2 Set up the indoor address using the temperature adjustment key Setup range 00 7F 3 A LV IA anal Group No Indoor No Program Set Clr 3 Press the Program amp Setup Cir keys at the same time for 3 seconds to set up the indoor address e The room address on the PDI is listed in the ascending order of indoor number Ex If the indoor addresses are 7C 7D 7E and 7F the order of the indoor unit on the PDI are 4 2 5 3 and a e The indoor numbers must be entered in sequence to be accurately recognized in the PDI Ex Correct indoor unit address setup 01 02 03 setup in order Incorrect indoor unit address setup 01 02 06 18 Electricity Distribution Indicator How to set each Indoor Unit E Using wireless remote controller 1 Address setting mode 1 With the top left key pressed press the Reset button Press the left key for more than 3 second ARATO 2 Using the temperature adjustment key set up the indoor unit 8 SAAR address ER Saill Setup range 00 7F DTME Gia TIME A wg8E priG88 Bw ex e No u
11. in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all 2 Electricity Distribution Indicator Cautions for safety I Cautions for safety To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications N AWARN NG This symbol indicates the possibility of death or serious injury C A CAUTIO N This symbol indicates the possibility of injury or damage to properties only J E Meanings of symbols used in this manual are as shown below OQ Be sure not to do L Q Be sure to follow the instruction J X A WARNING E WHEN INSTALLING You should always request product installation to our Service Center or to installation expert agency e Otherwise it may cause fire hazard electric shock explosion injury or damage Don t keep or use ignitable gas or any other flammable material in vicinity of the product e Otherwise it may cause fire hazard and product Pes failure Use specified parts e Or else it may cause fire hazard electric shock explosion injury damage and trouble failure SPECIFIED PARTS When reinstalling an existing installed product request it to our Service
12. next option 12 Electricity Distribution Indicator Installation After setting the product press p to select the next option 22 4 26 28 a MENU A v b SHIFT Press the p key to set up id aa e e the option for watt meter 16 i LGAP selection e Watt meter selection When the third 3 digits flash use the A or W key to select the meter constant of the watt meter 000 gt 1W P 001 gt 2W P 010 gt 4 W P 011 gt 6W P 100 gt 8 W P 101 gt 10W P Ex Product selection Master watt meter 2W pulse Not used 001 is set to 2 W 1 pulse and shows the meter constant of the watt meter 1 1 0 0 0 0 1 0 Master 2W p MICRONIC NO STBP After setting the product press p to select the next option User s Manual 13 Installation 22 34 26 38 m i MENU amp 5 b SHIFT Press the p key to select ana e w the option for standby 16 La LGAP power e Standby power indication selection When the forth digit flashes use the A or W key to select the standby power 0 NO STBP gt Does not show the standby power 1 CAL STEP gt Shows the standby power e Note If the PDI has been set Slave in previous option selection then Certainly Set NO STBP Ex Product selection Master standby power indication selection 1 is set to CAL STBP and shows you the standby power 11000004 Master 1W p MICRONIC CAL
13. se For Power Distribution Indicator Address e Used for Central Control settings check Address setting 3 After setting the address press the On Off key once directing the remote controller to the indoor unit 4 When indoor unit shows the setting address the address setup is complete The time and method of the address display can differ depending on the indoor unit type 5 Reset the remote controller and use it 2 Address check mode 1 With the top right key pressed press the Reset button Press the left key for more than 3 seconds 2 Press the On Off key once directing the remote controller to the indoor unit The indoor unit shows the setting address and the address setup is completed The time and method of the address display can differ depending on the indoor unit type 3 Reset the remote controller and use it Depending on the manufactured date of the wired wireless remote controller the above function might not work Since this is a function not relevant for consumer in using the product setup the remote controller to enable address setup during installation When setting the address refer to the details on the previous page User s Manual 19 Installation Guide Power Distribution Indicator and WHM should be installed in the specified cabinet which can protect the Power Distribution Indicator from water and humidity EX1 NOTE WHM Watt hour meter e
14. uct patron e Otherwise it may cause e If the product is impacted safety accident or product it may cause product trouble failure 4 Electricity Distribution Indicator Cautions for safety DEO ACAUTION k E WHEN USING Don t clean the product with strong detergent of solvents but only use soft cloth e Or else it may cause fire hazard and product deformation If water has been smeared Don t let metallic products on electric charge part use of necklace coin key watch it after removing water etc touch the battery terminal e Or else it may cause e Or else it may cause product product failure failure and injury User s Manual 5 Overview I Overview J E Functions e Accumulation of total power consumption e Indication of current power in use e Indication of accumulated power for period e Indication of standby power option setting E Specification e Power Supply 220 240V AC 50 60HZ 10 Dimension 200mm W X 120mm H X 55mm D e Connectable Units 1 Outdoor Unit per Electric Power Distribution Indicator E Count Method for Electric Power Distribution e Power Consumption of each Indoor Unit Power Consumption of Outdoor Unit x Weighting Power of each Indoor Unit Weighting Power of total Indoor Units e Weighting Power of each Indoor Unit Operation On Off x Capacity of Indoor Unit X LEV open rate X Fan step of Indoor Unit 6 Electricity
15. will be shown D Initial Screen ELECTRIC POWER MENU a v gt RENET Press Menu and Shift am Ea ap a I at same time i ic Leaf Option setup screen 00000000 Unit 1W p MICRONIC NO STBP e Product selection When the first two digits flash you can use the A or W key to set the product 00 gt Unit When using in connection with Independent operation of PDI and MultiV MultiV PLUS 10 gt Slave when using in connection with PC central controller 11 gt Master when not using in connection with PC central controller Ex Product selection Master Watt meter 1W 1 pulse 11 Independent operation of PDI 1111000000 Master1W p el MICRONIC NO STBP User s Manual 11 Installation After setting the product press p to select the next option MENU A nS SHIFT Commer Smee Coe 7 ic Laap Press the p key to set up the Option for remote reading service company selection e Remote reading service company selection Don t care selecting remote reading service ID When two digits flash use the A or W key to select the remote reading service company 00 gt MICRONICS 01 gt LSIS COM 10 gt CI TOPIA 11 gt OMNI SYS 00 1 1 00 0000 Master1W p MICRONIC NO STBP This setting does not care to use PDI After setting the product press p to select the