Home
User guide for power meter TM206
Contents
1. Press the power button to turn ON the power and put the device to operating mode If 199 9 comes up on the screen it suggests the device will become overloaded or has become overloaded OL In this case press the button and 1999 or your acquired value then comes up 6 3 TEST PROCEDURE Press the ZERO button for the zero adjustment if any digits is appear If performing the zero adjustment after powering on several digits may not disappear In this case perform the zero adjustment again Measure your car s headlights Turn ON your headlights Then turn ON the TM 206 solar meter and 00 0 appears on the screen Put the device down close to the headlights Switch between high beam and low beam and light intensity values appear on the screen Both the right and left headlights must be tested Note the values and put them in your car for reference Picture 2 Measure the effect of solar insulation of your vehicle s windows Press the button to turn ON the TM 206 solar meter 00 0 appears on the screen Aim the device at the sun and close to a window and the intensity appears on the screen Open the window and aim the device at the sun Compare the value against that acquired when the window is closed to understand the efficiency of the window s solar film Test your new car and preserve the measurements in it After that test it at least once every year Picture 2 N
2. OTE When the light sensor cover is not attached is indicated Make sure that it is attached If performing the zero adjustment after powering on several digits may not disappear In this case perform the Zero adjustment again 2 To test the sun s intensity put the device up close to the window y Turn ON the headlights and put the device down close to them to test their intensity Picture 3 To test the sun s intensity put the device close to the window Measure the solar insulation effect of your 5 windows Close the window Press the button your 206 solar meter 00 0 comes up the screen the device close to the window and aim it at the sun Compare the value against that acquired when the window is closed and the device is placed at the same position in order to understand the window s heat efficiency Picture 3 ELECTRIC SPECIFICATION Battery life approx 100 hr Accuracy typically within 10W m2 3 BTU ft2 h or 5 whichever aN is greater in sunlight Additional temperature induced error 0 38W m2 0 12 BTU ft2 h C from 25 Operating temp amp RH 5 C 40 C below 80 RH Storage temp amp RH 10 C 60 C below 70 RH DISPLAY 3 1 2 digits LCD with maximum reading 1999 Sampling Time Approx 0 25 second Resolution 0 1W m2 gt 0 1 BTU ft2 h Acc
3. TENMARS Solar Power Meter TM 206 User s Manual SOLAR POWER METER 206 4 HB2TM2060001 5 FO FEATURES NAME AND FUNCTION OF EACH PART SA LICAT ECTRIC FETY A BATTERY SE EN VICE OF LI FETY PRECAUTIONS AND PROCEDU 3 FOLLOWING SYMBOLS ARE USED ONS SPECIFICATION YD MAINTENANCE 1 FOREWORD Solar meter device used to measure solar power From the moment you buy such a product your future is not uncertain any more When the sun shines recklessly just take the TM 206 and aim its opening at the sun and you will see how powerful the sun is If you want your skin white you surely cannot do without it Measurement Expressed by W m or BTU R h 2 SAFETY PRECAUTIONS AND PROCEDURES This instrument conforms with safety Standard EN 61010 1 related to electronic measuring instruments For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol A follow the procedures described in this instruction manual For your own safety and to avoid damaging the instrument read carefully all notes preceded by this symbol A When taking measurements Be particularly careful when measuring voltages exceeding 20V to avoid ti
4. attery cover and reposition the protective holster 10 SERVICE Warranty Conditions This instrument is guaranteed for one year against material or production defects in accordance with our general sales conditions During the warranty period the manufacturer reserves the right to decide either to repair or replace the product Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The warranty doesn t apply to Accessories and batteries not covered by warranty Repairs made necessary by improper use including adaptation to particular applications not foreseen in the instructions manual or improper combination with incompatible accessories or equipment Repairs made necessary by improper shipping material causing damages in transit Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be reproduced in any form whatsoever without the manufacturer s authorization Our produ
5. cts are patented and our logotypes registered We reserve the right to modify specifications and prices in view of technological improvements or developments which might be necessary Service Shouldn t the instrument work properly before contacting your distributor make sure that batteries are correctly installed and working check the test leads and replace them if necessary Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The manufacturer will not be responsible for any damage to persons or things 11 END OF LIFE Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and Correct disposal
6. screen 6 Wim Wim2 0 7 BTU 2 g indi Low battery indicator 6 2 BUTTONS Power button Lock up Max and Min button Wim2 BTU ft2 h switch button Data Hold button Auto Range 6 2 1 Power button Press the alive Press the button once again to turn OFF the power and put the device go into sleep mode The display changes from light to dark button to turn ON the power The display comes 6 2 2 Lock up Max and Min button When you test in W m or BTU ft2 h press the button to display the max or min reading Press and hold the button for 1 second to allow the device to read the max value Press the button one more time to read the min value Press and hold the and min come off When the button is functional the button is disabled button for more than 1 second and the max 6 2 3 BTU ft2 h W m button Press the button to turn ON the power and put the device to operating mode The screen displays BTU ft h Press the button to switch from BTU ft h to W m To select a different unit just press this button once again 6 2 4 Data hold button Press the button to go into hold mode and 4 appears on the screen to allow you to read the data Press this button once again to deactivate it 6 2 5 Auto Range button Large integrated circuit design
7. sks of electrical shocks Avoid doing that in humid or wet places Avoid doing that in rooms where explosive gas combustible gas steam or excessive dust is present Keep you insulated from the object under test Do not touch exposed metal parts such as test lead ends sockets fixing objects circuits etc Avoid doing that if you notice anomalous conditions such as breakages deformations fractures leakages of battery liquid blind display etc 3 THE FOLLOWING SYMBOLS USED CAUTION refer to the instruction manual an improper use may damage the instrument or its components Danger high voltage risk of electric shock Double insulated meter AC voltage or current DC voltage or current Earth 4 APPLICATIONS Transmission measurement is most suitable for measuring the effectiveness of the solar film Solar radiation measurement Car windows light intensity measurement Optimal incident angle for the solar panel Measurement of the sun s transmission through transparent and film glass Convenient no need to adjust data displayed clearly 5 FEATURES Super low price high precision Measurable light sources including all visible light Overload display OL Select either W m2 or BTU ft2 h units1 Stable for long use 6 NAME AND FUNCTION OF EACH PART 6 1 THE LCD DISPLAY SHOWS 1 Data hold 2 Max value Min value H ue d Decimal point p numeral
8. uracy 3 year Over input Display shows OL Range 1999W m2 gt 634 BTU ft 2 h Dimensions amp weight 132 L x 60 W x 38 H mm approx 1500 this instrument is EMC compliant and has undergone compatibility tests according to EN61326 1997 1 1998 2 2001 ACCESSORIES User manual m 9V battery NEDA 1604 6F 22 JIS 006P 1 m carrying case 8 SAFETY AND MAINTENANCE Operating altitude below 2 000m Operating environment for indoor use expose to pollution level This is precision device During use or storage do not go beyond its 29 spec to prevent any possible damage or danger Do not put this device in direct sunlight or where it is hot and or damp Remember to turn OFF the power after use For long storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry soft cloth Wet cloths liquid and water are prohibited 9 BATTERY REPLACEMENT When the symbol displayed batteries need replacement CAUTION Before replacing batteries disconnect the test leads from energized circuits to avoid electrical shocks Turn OFF the meter and disconnect the test leads from the input terminals m Unscrew the battery cover and remove the battery Insert a new battery of the same type 9V NEDA1604 JISOO6P IEC6F22 observing the proper polarity re screw the b
Download Pdf Manuals
Related Search
Related Contents
X-03 UX-3 - ESOTERIC Wilo-Rexa FIT Istruzioni per l`uso - VEGASON 51K … 53K Mode d`emploi de la caméra DS-CAM R32HD Mode d`emploi Salsbury Industries 4975GRY Installation Guide MS10228-82_取扱説明書(PDF 197KB) Guía Rapida - Fisher Scientific Copyright © All rights reserved.
Failed to retrieve file