user`s manual portable air conditioner

image

Contents

1. control 4 Sealplate Control Panel 11 High ventilation indicator 12 Low ventilation indicator 13 Timer operation indicator 14 Display window 15 Sleep operation indicator 16 Cooling operation indicator 17 Dehumidity operation indicator 18 Fan operation indicator 19 Power indicator 1 POWER press this key to turn on off machine After machine turns on default value is cooling mode with low fan speed 2 MODE after machine turns on for cooling only model press this key to select cooling dehumiditying and fan mode FAN after machine turns on press this key to select fan speed high and low DOWN under cooling mode press this key to downward setting temperature from 16 31 C under timer mode press this key to downward on off time UP under cooling mode press this key to upward temperature from 16 317C under timer mode press this key to upward on off timer SLEEP under cooling press this key to turn on off sleep function TIMER under power on or standby mode press this key to setup on off time from 0 24 1 Remote Control Power 2 Timer 3 Down 4 Mode 5 Up 6 Fan 7 Sleep Operation Methods Cooling mode After machine turns on default value is cooling mode with 22 and low fan speed Press MODE to select cooling mode cooling mode indictor turns on Press UP or DOWN to adjust temperature from 16 to 31 Press FAN to select high or low fan s
2. USER S MANUAL PORTABLE AIR CONDITIONER wiry rin Ty Nae o90909 A TECHNICAL SPECIFICATION MODEL OAPC10 Voltage 220 240V 50Hz Power consumption 890W IMPORTANT SAFEGUARDS Please read this manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You will find many answers to common problems inside this manual CAUTION Contact the authorised service centre for repair of this unit This air conditioner is not intended for use by young children or infirm persons without Supervision Young children should be supervised to ensure that they do not play with the appliance If the power cord is damaged it must be performed by an authorised agent of Omega Altise SAFETY RULES To prevent injury to the user or other people and to prevent property damage the following instructions must be followed Incorrect operation due to not reading the instructions may cause harm or damage Your air conditioner should be used in such a way that It is protected from moisture eg splashed condensation water do not store or place the air conditioner where it can fall or be pulled into water Always transport the air conditioner in a vertical position and stand it ona stable level surface during operation Turn off the product when not in use A
3. hine run under fan mode for 2 hours to dry out the machine internals e urn off the appliance switch off the power point and remove the plug e Clean and dry filters then reinstall them e Pull out exhaust pipe for safekeeping e Put the machine into a plastic bag and place it on a dry place Troubleshooting Please contact professional serviceman without delay in following situation Power off Power on P2 flashes on screen or Machine geen Drain water out water full indicator turns on cannot work Turn off machine for three minutes Timer off turns on then restart it Direct sunlight Draw the curtains Door and windows are open Close the door and windows move out heat sources Machine auto many heat sources in the restarts room frequently Filters are too dirty Clean or replace filters Air inlet or air out let is eee Remove blockage Too noisy Machine is not on flat ground aae one ang peu avoiding shaking Compressor Compressor time delay Wait for 3 minutes then restart the cannot work protection turns on machine after temperature reduces Note If the machine is not working please contact your authorised agent Technical Data Mars o Feewat ROR Compressor a Fanspeods a mms o oo
4. lways contact an authorised qualified person to carry out repairs If the supply cord is damages it must be repaired by a qualified repairer Keep the are clear around the appliance There needs to be a air path of at least 30cm all around the unit from walls furniture and curtains If the air conditioner is Knocked over during use turn off the unit and unplug it from the powerpoint Do not operate the air conditioner in a wet room such as a bathroom or laundry Do not touch the unit with wet hands Do not press buttons on the console with anything but fingers Do not remove fixed covers Do not use this appliance if it is malfunctioning or has been dropped or damaged Never use the power point switch to start or stop the unit Use the control panel first Do not obstruct the inlet or outlet grill Do not use harsh chemicals to clean the air conditioner Do not run the unit near dangerous chemicals or insecticides or petrol Do not use this appliance for functions other than those described in this instruction manual ENERGY SAVING Use the appliance in the recommended room size Locate the unit where furniture cannot obstruct air flow keep blinds and curtains closed to keep out the sun Keep the filters clean Keep doors and windows closed to keep cool air in and hot air out Placement and Installation Placement Place the machine on flat and dry ground and keep at least 30 cm from walls etc figure 1 FIGURE 1 Installatio
5. n e Spin adapter into exhaust pipe first then spin the exhaust pipe into exhaust connector counter clockwise figure 2 e Put adapter into window seal plate adjust window open width in order seal plate match window well and the length of seal plate is adjustable FIGURE 2 FIG Installation Errors e Free access of exhaust pipe is important If air is not taken out it will affect performance of the appliance e Avoid sharp bends in the exhaust pipe figure 3 Make sure air in exhaust pipe can run smoothly figure 4 FIGURE 3 FIGURE 4 Warning Use only the exhaust pipe supplied Longer or extended pipes may damage the appliance Note extreme length of unfolding exhaust pipe is 1500mm please shorten the length as much as possible and keep it level as much as possible when installing Parts List Front side figure 5 1 Handle 2 Control Panel 3 Air outlet 4 Fan blade 5 Castor Rear Side figure 6 6 Filter frame upper 7 Exhaust Connector 8 Power Cord Location 9 Filter frame lower 10 Rubber plug 11 Plug cap 12 Power Supply Cord Accessories figure 7 1 1 Exhaust Pipe 2 Adapter ON OFF power button Mode function button sleep function button Temperature down button Temperature up button Timer button speed ventilation button Receiver for remote control Water Full indicator 0 Indicator for compressor OS NOOR NS FIGURE 7 3 Remote
6. peed Fan mode Press MODE to select fan mode fan mode indicator turns on Press FAN to select fan speed press UP or DOWN to select high speed or low speed Temperature and sleeping function cannot be setup Timer mode e Under standby mode press TIMER to setup the power on time press UP and DOWN to adjust the timer from 1 to 24 Timer indicator turns on e Under power on mode press TIMER to setup power off timer Press UP and DOWN to adjust the timer from 1 to 24 Timer indicator turns on Dehumidifying mode e Press MODE to select dehumidifying mode dehumiditying mode indicator turns on e Under dehumidifying mode timer and sleeping function cannot be setup and fan speed is low Sleep mode e Press key SLEEP enter into sleeping mode default value of fan speed is low e When sleeping mode turns on under cooling mode one hour later temperature will go up 1 C from setting temperature and then keep the same under heating mode one hour later temperature will go down 1 C from setting temperature and then keep the same e Sleep mode is invalid under dehumidifying and fan mode Under water full machine standby and mode conversion sleeping mode will be cancelled Compressor protection If turned on and off or on at start up it takes 3 minutes for the compressor to start Water Drainage This machine has a auto water evaporating sy
7. stem Condensed water cycle is used to cool down the condenser which not only improves cooling efficiency but also saves energy If inner water tank is full W F indicator will flashed on the screen 8 seconds later machine enter into standby mode buzzer shouts compressor stops and all keys is invalid till machine recovers to be normal Pull out the plug to drain out water power off the machine and restart it the machine will runs normally Maintenance Note in order to avoid electric shocks please turn off at the control panel switch off the power point then unplug the appliance before cleaning Cleaning Please switch off at the control panel then at the power point then unplug before Cleaning Use soft semi dry cloth to clean the machine Don t use chemical agents such as benzene alcohol gasoline etc otherwise the machine surface can be damaged Use only a moist cloth not a wet or dripping as if water enters the control panel or the machine it will cause damage Filter Clean the filters every two weeks if filters are blocked by dust machine efficiency will be reduced Clean the filters in warm water with neutral detergent then dry the cleaned filters on a shady place Note Don t run the machine without filters seasonal Cleaning If the machine is not be unused for a long time please follow these steps e Pull out drainage plug upper lower to empty any water out e Let the mac

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation iView MediaPro 2.5.1  Manual del propietario  Piano di Sicurezza e Coordinamento - Bandi on-line  ・同封されているパーツ ・装着方法について  Tektronix Switch 834 User's Manual  Présentation du Forum Forêt - Centres Régionaux de la Propriété  KBS-1400 manual  取扱説明書 - 日立の家電品  PumpMeter Betriebs-/ Montageanleitung  HLA B5701 Real  