Home
- Axceleon
Contents
1. Services Performance Networking Users Image Name User Name CPU Memory Description CodeMeterCC exe 32 admin 00 3 700K CodeMet conhost exe admin 00 1 788K Console conhost exe SYSTEM 00 1 732K Console conhost exe SYSTEM 00 1 708K Console csrss exe SYSTEM 00 1 128K Client Ser csrss exe SYSTEM 00 2 196K Client Ser SE GE 00 21 556K Desktop enfDispatcher exe 32 SYSTEM 00 3 532K enfDispat enfeye exe 32 SYSTEM 00 2 524K enfeye enfNodeServer exe 32 admin 00 3 200K enfNodes enfStarterSvc exe 32 SYSTEM 00 1 316K enf tarte SOT EXE Je 00 42 472K Windows jusched exe 32 admin 00 1 868K Java Upd Isass exe SYSTEM 00 3 136K Local Sec Ism exe SYSTEM 00 1 068K Local Ses V Show processes from all users 0009 Processes 52 CPU Usage 0 Physical Memory 6 Figure 4 6 EnFuzion Processes Step 5 Browse to locate the EnFuzion3D license file when prompted Step 6 Finish the installation process by registering and starting the EnFuzion Root Services as the default values suggest Click Finish to conclude Control Root Computer installation as shown in Figure 4 7 24 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE x Setup EnFuzion3D Version 15 0 3133 Axceleon Completing the EnFuzion3D Setup Wizard Setup has finished installing and configuring EnFuzion3D on your computer Click Finish to perform the tasks below and e
2. Computers and all the Compute Nodes We recommend that you always install EnFuzion3D at the same location so that your new installation will be able to find your user files at their default locations e The EnFuzion services associated with the new version of EnFuzion3D should be started by default during the installation process If for any reason blocked ports anti virus programs the EnFuzion processes fail to start you can manually start the necessary EnFuzion processes after you resolve the problems To see how to manually start EnFuzion services please see the section below titled Start Stop EnFuzion Services 6 2 Updating Your EnFuzion3D License File 45 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE EnFuzion3D license files are version dependent When you upgrade your version of EnFuzion3D you need to contact Axceleon at support axceleon com to obtain a new license file After you receive a new license file there are two ways to get a new version of EnFuzion3D software to work with a new license file e Method 1 When you install a new version of EnFuzion3D on a Control Root Computer you will be prompted for a new license file e Method 2 If you have already installed a new version of EnFuzion3D before you received a new license file follow the steps below to configure your new software to use a new license file o Rename the new license file to enflicense txt o Copy it to the lt EnFuzion3D Installation Directory gt C
3. Rescheduled 0 Show My Runs V Auto Update a eee el Run ID Submission User Status Uptime FinishIn Priority Application NodeID Host EI rl WIN7 32 Ic r Completed Runs m EI Completed Runs 0 Jobs Waiting 0 Done 0 Failed 0 Rescheduled 0010 0 il Sh 02d 0 00 Runs V Auto Update RunID a Submission User Status Submitted Completed Uptime Wi fom m Welcome to EnFuzion3D 15 0 Figure 3 10 EnFuzion3D Desktop 3 6 Troubleshooting installation Problems This section describes some common installation problems and how to overcome them 3 6 1 Error Messages During Installation When you did not have administrative privilege or did not install EnFuzion3D using the Run as administrator as suggested you may encounter one of more of the following error messages below Unable to execute file C EnFuzion3d bin enfstartup CreateProcess failed Code 740 The requested operation requires elevation Unable to execute file C EnFuzion3d bin enfstartup CreateProcess failed Code 740 The requested operation requires elevation Unable to execute file C EnFuzion3d bin enfnodescp CreateProcess failed Code 740 The requested operation requires elevation When this happens we suggest you re install EnFuzion3D as an administrator or using the Run as administrator as required You can also try manually starting these EnFuzion processes manually by following the steps in the sections below 12 ENFUZION3D INSTAL
4. ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 8 Installing EnFuzion3D on Artist Workstations User Submit Computer Users of your render farm will submit scenes from their workstations You must install the EnFuzion3D User Submit Computer software on all the user workstations You can have as many of these machines as you need because their number is not limited by your EnFuzion3D license Follow the steps below to install the User Submit Computer software on an artist workstation Completing these steps will give the partial render farm shown in Figure 4 9 User Submit Control Root Computer Computer Figure 4 9 Adding a User Submit Computer Step 1 Select a User Submit Computer login as the normal user of the workstation Step 2 Download the EnFuzion3D software and run the EnFuzion Setup program as the normal user Administrative rights are not needed In the EnFuzion3D Setup Wizard select the User Submit Computer Installation option as shown in Figure 4 10 x Setup EnFuzion3D Version 15 0 3133 Axceleon Select Components Vs Which components should be installed ON lt Select the components you want to install dear the components you do not want to install Click Next when you are ready to continue fl Submit Computer installation v T Compute Node d User Submit Computer 52 9 MB Current selection requires at least 53 6 MB of disk space ae C s Figure 4 10 Install and Configure a User S
5. Root Service will start automatically after the installation is complete TE GE x A Setup EnFuzion3D Version 15 0 3133 Axceleon Select Additional Tasks WE Which additional tasks should be performed Ons Select the additional tasks you would like Setup to perform while installing EnFuzion3D then dick Next EnFuzion Service on the Control Root Register and Start EnFuzion Service Figure 4 4 Configure Control Root Service 23 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE If you encounter an error message as shown in Figure 4 5 it is because a previously installed EnFuzion Root Service process is still running on this machine You need to stop it before proceeding You can stop this process from the Windows Task Manager It is a good idea to stop all running EnFuzion processes using the Windows Task Manager before you install a new version of EnFuzion3D All the EnFuzion processes are shown in Figure 4 6 below More details on how to upgrade an existing installation are in Chapter 6 Upgrading a Previous Installation of EnFuzion3D i G EnFuzion Bin glib 1 2 dll An error occurred while trying to replace the existing file DeleteFile failed code 5 Access is denied Click Retry to try again Ignore to skip this file not recommended or Abort to cancel installation Figure 4 5 Stop Previously Installed Processes Wal Windows Task MAE Em File Options View Help Applications Processes
6. Run the EnFuzion3D Installer using Run as administrator as shown in Figure 4 1 il Run as administrator JG o b EnFuzion3D 15 0 3133 Windows 32bit 20150426 224158 gt ww Organize v Include in library v Share with v Burn New folde Share with r Favorites Name j Da Restore previous versions d downloads 2 L di Licenses 5 Send to Fl Desktop AGREEMENT tt Ad 9KB NA Downloads dita we 4 1 Cut 1 KB E Recent Places 2 Setup EnFuzion3D 15 0 3133 exe 4 Copy 4 KB x Create shortcut Delete Rename Properties Figure 4 1 Install EnFuzion3D as Windows Administrator This will open the EnFuzion3D Setup Wizard and let you install EnFuzion3D with administrative privilege 4 7 Installing EnFuzion3D on the Control Root Computer Follow these steps below to install EnFuzion3D on the Control Root Computer Step 1 Select your Control Root Computer and note its Fixed IP Address Step 2 Run the EnFuzion 3D setup program as an Administrator by following these steps exactly 21 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE e Identify the user account that your rendering software is installed under login as that user e Copy the EnFuzion download image to this machine e Extract the EnFuzion3D Installer 7 EnFuzion3D 1 5 03133 Win dows 32brt2 0150426 2241 H Right Click gt Extract All e Open the EnFuzion3D Installer mM EnFuzion3D 1 5 0 3133 Win dows 32bit 2 0150426 2241 z
7. Start gt All Programs gt EnFuzion gt Control Root EnFuzion Root Service Utilities gt Register EnFuzion Root Service Start gt All Programs gt EnFuzion gt Control Root Utilities gt Stop EnFuzion Root Service e enfDispatcher exe Start gt All Programs gt e enfeye bin exe EnFuzion Control Root Utilities gt Start EnFuzion Root Service Start gt All Programs gt EnFuzion gt Control Root EnFuzion Node Service Utilities gt Register EnFuzion Node Service Start gt All Programs gt EnFuzion gt Control Root Utilities gt Stop EnFuzion Node Service e enfNodeServer exe Start gt All Programs gt e enfStartersvc exe EnFuzion gt Control Root Utilities gt Start EnFuzion Node Service Table 6 1 Start Stop EnFuzion on Windows platform 6 6 Upgrading your EnFuzion3D Installation On the Windows platform the graphical installer will prompt you to upgrade your installation of EnFuzion3D if an older release is detected on your machine You should install the new version of EnFuzion3D at the same location as your old version so that all of your user configurations files will be used by the new version of EnFuzion3D The new EnFuzion3D configuration files will be created with a new extension You can decide when you want to upgrade to the new version of configuration files 6 7 Additional Information For addition information on EnFuzion please refer to the EnFuzion User Manual For technical suppor
8. administrator 3 1 Computers Users and User Privilege EnFuzion3D uses Windows Services to implement control and communications between the Control Root Computer and Compute Nodes EnFuzion3D therefore requires administrative privilege to install and execute on the Control Root Computers and Compute Nodes On the Compute Nodes EnFuzion3D must have the same environment settings as the rendering software it calls to do the actual rendering The easiest way to make sure Is to install and run EnFuzion3D using the same user as what you used to install and run your rendering software Please make sure to follow the requirements in Table 3 7 to install EnFuzion3D One Machine Control Root User Submit Compute Configuration Computer Computer Nodes The same user that Log in as this user to EEG Piet ia The normal artist you used to install and install EnFuzion3D user run your rendering software e g Maya User Privilege required to install Administrator Administrator Administrator The same user that EnFuzion3D will ce SCH you used to install and execute as this user Poe SESCH run your rendering software e g Maya Table 3 1 Installation Requirements ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 3 2 Windows User Access Control UAC Settings By meeting the requirements on user privilege settings in Table 3 1 you will be able to run EnFuizon3D with the Windows User Access Control setting at any level 3 3 Windows Firew
9. of EnFuzion3D i C EnFuzion Bin glib 1 2 dll An error occurred while trying to replace the existing file DeleteFile failed code 5 Access is denied Click Retry to try again Ignore to skip this file not recommended or Abort to cancel installation Figure 4 17 Stop Previously Installed Processes fms Windows Task Mans moms File Options View Help Applications Processes Services Performance Networking Users Image Name User Name CPU Memory Description CodeMeterCC exe 32 admin 00 3 700K CodeMet V conhost exe admin 00 1 788K Console conhost exe SYSTEM 00 1 732K Console conhost exe SYSTEM 00 1 708K Console csrss exe SYSTEM 00 1 128K Client Ser csrss exe SYSTEM 00 2 196K Client Ser Fe Pee FER 00 21 556K Desktop enfDispatcher exe 32 00 3 532K enfDispat enfeye exe 32 00 2 524K enfeye enfNodeServer exe 32 i 00 3 200K enfNodeS enfStarterSvc exe 32 00 1 316K enfStarte XDIOTeT EXE 30 00 42 472K Windows jusched exe 32 admin 00 1 868K Java Upd sass exe SYSTEM 00 3 136K Local Sec Ism exe SYSTEM 00 1 068K Local Ses v V Show processes from all users elie Processes 52 CPU Usage 0 Physical Memory 6 Figure 4 18 EnFuzion Processes Step 5 Complete the installation and ask the setup wizard to start the EnFuzion Compute Node service upon completion of installation Note that your Computer Node h
10. up file sharing If you have at least one remote Compute Node you must first set up file sharing between your User Submit Computer and your Compute Nodes so that your Compute Node can read your scenes your project files and store rendered images There are two ways to set up file sharing e Shared File Repository A render farm manager sets up a file server to hold all the scenes project directories and images directories for all the users and computers on a render farm If you are a render farm administrator and want to set up a Shared File Repository please refer to Chapter 4 Setting up File Sharing e Simple File Sharing You manually share your own project directories and images directories so that you can use distributed rendering without a render farm wide Shared File Repository Refer to Simple File Sharing section in Chapter 4 Setting up File Sharing Distributed rendering will fail without functional file sharing Please make sure before you submit your first test scene Step 2 Login as a render farm user e Ona One Machine Render Farm you can do the tests as the Administrator user e Ona Three Machine Render Farm log on to the User Submit Computer as if you re an artist Step 3 Start EnFuzion3D Desktop and Select Maya as shown in Figure 4 20 33 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE UG EnFuncalD elei D gt EA hi E a E A A CG ZS user peter un7 32 Root Host loca
11. 15 0 3133 Axceleon Configure Compute Node Vs Configure User Submit Computer Vs How does this Compute Node connect to the Control Root computer Ons What is the address of the EnFuzion service on the Control Root computer Ons Provide the network name or address of the Control Root computer Click Next to continue with the installation EnFuzion Service Host localhost EnFuzion Service Port 10102 Notice The default port value 10102 rarely needs to be changed Do not change this value without changing the default EnFuzion service port on the Control Root computer lt Back net gt Figure 3 5 Default Configurations If you encounter the error message as shown in Figure 3 6 it is because a previously installed EnFuzion process Is still running on this machine the Windows Task Manager You need to stop it before proceeding You can stop this process from i CAEnFuzion Bin enfStartersvc exe An erro DeleteF r occurred while trying to replace the existing file ile failed code 5 Access 15 denied Click Retry to try again Ignore to skip this file not recommended or Abort to cancel installation It is a good idea to stop all running EnFu Figure 3 6 Previous Installation of EnFuzion3D Detected zion processes using the Windows Task Manager before you install a new version of EnFuzion3D All the EnFuzion processes are shown in Figure 3 7 below More details on how to upg
12. As shown in Figure 4 16 tell this Compute Node how to connect to your Control Root Computer by providing the Fixed IP Address of the Control Root Computer that you set up earlier For our example the IP address is 192 168 58 5 RE EE tup EnFuzion3D Version 150 0 3133 Axceleon x Configure Compute Node Vs How does this Compute Node connect to the Control Root computer Ons Provide the network name or address of the Control Root computer Click Next to continue with the installation EnFuzion Control Root Host 192 168 58 5 Port for Node Connections 10103 Notice The default port value 10103 rarely needs to be changed Do not change this value without changing the default EnFuzion service port on the Control Root computer Figure 4 16 Configure the Compute Node with Control Root Computer IP Address 30 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE If you encounter an error message as shown in Figure 4 17 it is because a previously installed EnFuzion Root Service process is still running on this machine You need to stop it before proceeding You can stop this process from the Windows Task Manager It is a good idea to stop all running EnFuzion processes using the Windows Task Manager before you install a new version of EnFuzion3D All the EnFuzion processes are shown in Figure 4 18 below More details on how to upgrade an existing installation are in Chapter 6 Upgrading a Previous Installation
13. Create a miniature Three machine Render Farm by creating a Control Root Computer and adding 1 User Submit Machine and i Compute Node Machine as shown in Figure 2 14 Before you add any more users or machines to your render farm it is critical that you can successfully render some scenes on this miniature render farm Networking and file systems problems are easier to spot and resolve at this stage If this configuration doesn t work perfectly adding more machines and more users will create more confusion at this stage Step 3 Add more render nodes and users to your render farm after you have successfully completed Step 3 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Figure 2 4 Three machine Minimal Render Farm 2 5 Next Steps If you are installing EnFuzionsD for the first time please proceed to Chapters 3 Installing EnFuzion3D on Windows Platform for instructions on how to install and configure EnFuzion3D on Windows platform If you are upgrading your current version of EnFuzion3D please proceed to Chapter 5 Upgrading a Previous Installation of EnFuzion3D ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 3 EnFuzion3D Quick Start Guide Setting up a One machine Render Farm This Chapter describes the quickest way to test drive EnFuzion3D by creating a One Machine Render Farm This will only take a few minutes If you are new to EnFuzion3D we strongly suggest you start here Skip ahead if you are an experience render farm
14. LATION AND CONFIGURATION GUIDE 3 6 2 The EnFuzion3D Web Interface Does Not Start When the EnFuzion Web Interface at http localhost 10101 doesn t start you should check the EnFuzion Root Service Log file first to see the reason and then take the appropriate corrective actions To access the EnFuzion Root Service Log file choose Window Start gt EnFuzion3D gt AII Programs gt Show EnFuzion Root Service Log as shown in Figure 3 11 e Windows Media Center Windows Media Player a Windows Update XPS Viewer A 7 Zip peter di Accessories de Cygwin A Cygwin X A Demo Builder 10 Documents Pictures Music xX EnFuzion3D Desktop __ Show Install Log __ Show Submission Log CO Uninstall EnFuzion3D Computer Games Compute Node L Control Root Jtilities Control Panel le Register FoFuzion Root Service Devices and Printers start EnFuzion Roc ce em Stop EnFuzion Root Service Default Programs Unregister EnFuzion Root Servic User Submit Utilities Help and Support Back Figure 3 11 Accessing EnFuzion Root Service Log 3 6 3 Manually Starting the EnFuzion Root Service The EnFuzion Web Interface at http localhost 10101 will not start if the EnFuzion Control Root processes enfDispatcher and enfeye did not start successfully You can confirm this from the Windows Task Manager You can manually start these processes by choosing the following as shown in Figure 3 12 e Windows Start gt All Pr
15. Right Click Open e Run the EnFuzion3D Installer using Run as administrator as shown in Figure 4 2 Li Run as administrator wey m EnFuzion3D 15 0 3133 Windows 32bit 20150426 224158 Organize v Include in library w Share with Burn New folde Share with A r Favorites Name Da Restore previous versions d downloads 2 L di Licenses 5 Send to gt RB Desktop AGREEMENT txt Ad 9KB NM Downloads BE AD NAT ing 4 Cut 1 KB Xe Setup EnFuzion3D 15 0 3133 exe Recent Places Ad Copy Create shortcut Delete Rename Properties Figure 4 2 Install EnFuzion3D as Windows Administrator This will open the EnFuzion3D Setup Wizard and let you install EnFuzion3D with administrative privilege Step 3 Select the Control Root Installation option in the EnFuzion3D Setup Wizard as shown in Figure 4 3 22 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE A Setup EnFuzion3D Version 15 0 3133 Axceleon x Select Components AR Which components should be installed d lt Select the components you want to install dear the components you do not want to install Click Next when you are ready to continue User Submit Computer 52 9 MB Current selection requires at least 34 4 MB of disk space Figure 4 3 Control Root Installation Step 4 Take the default setting on Register and Start EnFuzion Service option as shown in Figure 4 4 so that the EnFuzion
16. SD sa 36 4 15 Additional Resources for Render Farm Administrators ccccceseccsssscccesecccesscceeescesauseceseseceesnses 36 TONEN RER 36 Sening Up File Sharing aiins aa aa LE 37 SC Eet Ge ee GE 37 52 Fe SAOMING WILR SQINDG EE 38 5 3 Setting up a Shared File Repository Summary Of Steps 38 5 4 Configuring File Sharing on Windows Based Computers rrrrrrrrnnrrrrnnnrrrnnnnrrnnnnrrrnnnrrrnnenrrnnensernner 39 5 5 Configuring File Sharing on Linux Based Computers 39 5 6 Configuring File Sharing on Mac OS X Based Computers 41 Upgrading a Previous Installation of EnFuzion3D eeennnnvvervnnnnnnevnnnnnnnnnennnnnnnnnnnnnnnnnnennnnnnnnnennnnnnnnnennnnn 45 6 1 Planning GM EnFuzion3D UPGr de dead 45 6 2 Updating Your EnFuzion3D License File 45 6 3 Re hosting Your EnFuzion3D Control Root Computer 46 6 4 Managing Different Versions of Entusion f 46 65 Start SEOD EN FUZION SCIVICES nende dej 46 6 6 Upgrading your EnFuzion3D fnstollotion 47 67 Additional ormalonuvasaesasqavvadesien eee 47 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 1 Introduction Welcome to EnFuzion3D render farm management software This guide describes the process of installing and running EnFuzion3D on a render farm This guide is organized as follows Chapter 1 Introduction Chapter 2 Overview of an EnFuzion3D Managed Render Farm This chapter introduces EnFuzion3D concepts and terminology along with a recommended way to set up EnFuzio
17. SEE Music Oe EnFuzion3D Desktop L Show Install Log __ Show Submission Log Su ES Games ninstall EnFuzion3D Computer Control Panel E Register EnFuzion N 7 Show Node Log Show Node Log 2 Devices and Printers Default Programs Help and Support P Joel d f ER E f mmm i x Eh i d d 7 S om navi mile j we Figure 3 14 Manually Starting EnFuzion Node Service After you manually start the EnFuzion Compute Node Service you can try re open the EnFuzion Web Interface by opening a browser and type in http localhost 10101 and check to see if you have 1 Active Node 3 6 6 More Troubleshooting Tips Most common installation problems are due to these reasons e You did not install EnFuzion3D as an administrator e Invalid or expired license file e Blocked TCP IP port that EnFuzion needs e Antivirus software preventing system processes from starting e The EnFuzion3D program cannot log in on Compute Nodes using the password you supplied during the installation EnFuzion3D keeps extensive Log Files to help you identify problems We suggest you check the EnFuzion Root Service Log and Node Service Log files to identify the source of the problems More diagnostic tips and solutions for these problems can be found on line at http www enfuzion3D com faq html 16 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 3 7 Test Drive EnFuzion3D After you verify that EnFuzion3D is run
18. SMB Client on an EnFuzion Compute Node On a Windows based Compute Node you do not need to do anything to enable a SMB Client Once a SMB Server has been properly configured verify that you can access shared files in your Shared File Repository by selecting Windows gt Start gt Network on the Compute Node 5 4 4 For AllWindows Users Only For all Windows users it is possible to start without a central Shared File Repository Please see the section above titled Simple File Sharing to see how 5 5 Configuring File Sharing on Linux Based Computers This section provides the information on configuring Linux machines for SMB based file sharing including e How to enable file sharing on a Linux based SMB Server and e How to configure Linux based SMB Clients on User Submit Computers and the Compute Nodes Please see below for details 39 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 5 5 1 Configuring a Linux SIVIB Server The steps to enable file sharing on a Linux SMB Server are beyond the scope of this guide Please contact your systems administrator or contact Axceleon if you have questions on how to set up a Linux server for file sharing 5 5 2 Configuring a Linux Based SMB Client on an EnFuzion Compute Node To configure a SMB Client on a Linux based Compute Node please follow the steps below Step 1 Login as a root super user and create a mount point with the following command mkdir p mnt lt share name gt Step 2 Create
19. Ss axceleon Axceleon EnFuzion3D 2015 Installation Guide For Windows Users EnFuzion3D 2015 Installation Guide Legal Notices EnFuzion3D 2015 Installation Guide for Windows Users Document Version 15 0 Release 20150614 Copyright 2002 2015 Axceleon Inc All rights reserved Axceleon and EnFuzion3D are trademarks of Axceleon Inc EnFuzion and CloudFuzion are registered trademarks of Axceleon Inc All other trademarks mentioned herein are properties of their respective owners Axceleon Inc 19925 Stevens Creek Blvd Suite 100 Cupertino CA 95014 Phone 714 213 8209 Email info axceleon com Web www enfuzion3d com Contents 1 Mode 1 2 Overview of an EnFuzion3D Managed Render Farm nnrernnnnnnnvennnnnnnnnennnnnnnnnennnnnnnnnennnnnnnnvennnnnnnnennnnnnnnnenn 2 2 1 Key Components of an EnFuzion3D Managed Render Form 2 2 Mixed 05 ele geg re EE 3 2 3 How does EnFuzion3D work u uiccccssesccccssesccccsneseccssassccssausecessuusecesausecessaussesssausecesauusecsssassessaaanses 4 2A EENEG 4 FNS 5 3 EnFuzion3D Quick Start Guide Setting up a One machine Render Farm nnernnnnnnnnnnnnnnnnnvennnnnnnnvennnnn 6 3 1 Computers Users and User Privilege cccccsesecccnssecccnsececcnseeccseceeenecseasesssusecssuesesseusesteesecesagses 6 3 2 Windows User Access Control UAC Settings sccccccececcceeecscccecsecececscececssscessceeesssseeessseeessseenss 7 3 3 Windows Firewall Settings sacsiccorsscccds
20. XPS Viewer Ak 7 Zip peter di Accessories d Cygwin AR Cygwin X AR Demo Builder 10 EnFuzio n3D oe EnFuzion3D Desktop L Show Install Log L Show Submission Log aS Uninstall EnFuzion3D Computer Documents Pictures Music Games Lor pt te Spade Utilities E Register EnFuzion Node how Node Log 1 FT Show Node Service Log LR Default Programs Stop EnFuzion Node Service E Unregister EnFuzion Node S Control Panel Devices and Printers Help and Support Ke 4 Back 2 Shar down em JG JG C e Figure 3 13 Accessing EnFuzion Node Service Log 3 6 5 Manually Starting the EnFuzion Node Service The EnFuzion Web Interface at http localhost 10101 will show 0 Active Nodes if the EnFuzion Compute Node processes enfNodeServer and enfStarterSvc did not start successfully You can confirm this from the Windows Task Manager You can manually start these processes by choosing the following as shown in Figure 3 14 e Windows Start gt All Programs gt EnFuzionaD9Compute Node Utilities gt Register EnFuzion Node Service and e Windows Start gt All Programs gt EnFuzion3D gt Compute Node Utilities gt Register EnFuzion Node Service 15 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Windows Media Center Windows Media Player LA Windows Update i XPS Viewer A 7 Zip peter A Accessories d Cygwin Cygwin X J Demo Builder 10 Documents Pictures
21. a share description in the etc fstab file on the Compute Node by adding the following line to the file lt server name gt lt share name gt mnt lt share name gt Smbre username enfuzion password lt password gt uid enfuzion gid enfuzion 0 0 Example We have a Shared File Repository located on the machine 192 168 0 160 SharedRepository We wish to mount this Shared File Repository from an EnFuzion Compute Node using the directory mnt SharedRepository To accomplish this create a etc fstab file on the Compute Node and add the following line 192 168 0 160 SharedRepository mnt SharedRepository smbfs A username enfuzion password enfuzion uid enfuzion gid enfuzion 0 0 Step 3 Mount the new share with the following command mount mnt lt share name gt Step 4 Confirm the SMB mount with the following steps e Login as enfuzion e From a command prompt type cd mnt lt share name gt and confirm that files can be read from and written to the Shared File Repository 5 5 3 Configuring a Linux SMB Client on an User Submit Computer To configure the SMB Client on a Linux based User Submit Computer please follow the steps below Step 1 Login as a root super user and create a mount point with the following command mkdir p mnt lt share name gt Step 2 Create a share description in the etc fstab file on the Compute Node by adding the following line to the file lt server name gt lt share name gt mnt lt sha
22. aces ZG Setup EnFuzion3D 15 0 3133 exe 4 Copy Create shortcut Delete Rename Properties Figure 3 1 Install EnFuzion3D as Windows Administrator This will open the EnFuzion3D Setup Wizard and let you install EnFuzion3D with administrative privilege 3 5 Installing a One machine Render Farm Follow these steps below to install EnFuzion3D on your One machine Render Farm Step 1 Select the Test Install on One Computer option and accept all the default values as shown in Figure 3 2 E TE ee P Setup EnFuzionaD Version 15 0 3133 Axceleon Select Components Jr Which components should be installed Ons Select the components you want to install dear the components you do not want to install Click Next when you are ready to continue Test Install on One Computer e T EnFuzion Service on the Control Root 33 7 ME Compute Node 33 2 MB User Submit Computer 52 9 MB Current selection requires at least 59 6 MB of disk space Figure 3 2 Test Installation on One Computer ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Step 2 When prompted to provide an EnFuzion3D License File browse to locate your enflicense txt file Setup EnFuzionsD Version 15 0 753 Axceleon Install EnFuzion License Key EnFuzion requires two license files a root license lic and a node license tut Select the license files then dick Next EnFuzion node license file txt Figure 3 3 EnFuzion3D License File Step 3 When prom
23. all Settings EnFuzionsD runs on a client server architecture to ensure high performance and scalability All the Compute Nodes must be able to communicate with the EnFuzion3D Control Root Computer which they do by running a service called enfStarterSvc exe On all Compute Nodes in Windows firewall settings please make sure to set up the following e Allow the program lt EnFuzion3D Installation Directory gt EnFuzion Bin enfStarterSvc exe to accept inbound connections and e Make sure that this program can use ports 17000 17005 3 4 Run EnFuzion3D Installer as a Windows Administrator Follow these steps exactly to make sure that you install EnFuzion3D as a Windows Administrator e Identify the user account that your rendering software is installed under login as that user e Copy the EnFuzion download image to this machine e Extract the EnFuzion3D Installer Gamal Right Click gt Extract All e Open the EnFuzion3D Installer Right Click Open e Run the EnFuzion3D Installer using Run as administrator as shown in Figure 3 1 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Bun as administrator A EnFuzion3D 15 0 3133 Windows 32bit 20150426 224158 7 Zi p Pindo DD p Organize v Include in library v Share with e Burn New Tolde Share with gegen Name i Da Restore previous versions di downloads 2 Ak Licenses 5 Send to d E Desktop __ AGREEMENT txt A ET Downloads DE AD RAE id Ad Cut E Recent Pl
24. as been configured to automatically connect to the Control Root Computer after the installation is completed and after each time you boot restart the machine Verify that the Compute Node is connected successfully to the Control Root Computer using the EnFuzion Web Interface as shown in Figure 4 19 You may have to wait for up to two minutes for the Compute Nodes to connect to the Control Root Computer 31 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE EE ET E a Cluster Summar y E A GAR O ASNN eja Seren G f ei Home Cluster Nodes Runs Accounting Execution Submit Results Cluster test PC 10102 Cluster Status Uptime Active Nodes Down Nodes Submitted Runs Completed Runs test PC 10102 Running 00 00 11 1 0 0 Nodes Active Executing Idle Busy Down Nodes 1 0 1 0 Runs Created Started Stopped Done Failed Runs 0 0 0 0 Messages Time Object Message Figure 4 19 Confirm the New Computer Node Is Running 4 9 3 EnFuzion Node Start up Script for Windows based Compute Nodes EnFuzion3D provides a convenient way for users to configure the Compute Nodes each time when they are started or restarted You can do this by creating a Node Start up Script for each Compute Node This is especially import when the Compute Nodes need to mount a Shared File Repository so that they can access project directories and image directories Please note the following requirements for an EnFuzion Node Start up Script e It must be named s
25. bmission corresponds to an EnFuzion3D Active Run with its own Run ID as shown in Figure 4 22 You monitor the rendering progress using the EnFuzion3D Desktop e Big EnFuzion3D EnFuzion3D Submit View Tools Help A A D 3 cA 3 ar e A A H 7 i User admin testPC Root Host 192 168 58 5 x EnFuzion Web Compute Nodes 6 Nodes Total 1 Active 1 Down 0 Active Nodes Executing 0 Idle 1 Unavailable l V Auto Update NodeID Host Status 0000000001 tenderintro admin started 00 00 01 0 50 Maya su 0 1 d TEST PC Idle Active Runs 1 Jobs Waiting 0 Executing 1 Done 0 Failed 0 Rescheduled0 BEE 8 i Show My Runs V Auto Update Submission User Status Uptime FinishIn Priority Application Pools Waiting Executi Done Fai Completed Runs ax Completed Runs 4 Jobs Waiting 726 Done 2 Failed 0 Rescheduled 20 ae Show My Runs Sen Recent Runs V Auto Update RunID a Submission User Status Submitted Completed Uptime Waiting Done Failed Rescheduled Job Li 0000000000 Renderlntro admin done Wed May 0 Wed May 0 00 00 15 0 1 1 0 0 00 00 0000000006 3dsmax 20 bob failed Sun May _ Sun May 0 00 08 31 6 6 0 H 10 K m Figure 4 22 Monitoring Rendering Progress 34 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Once rendering completes an Active Run become a Completed Run as shown in Figure 4 23 You can get more information on by clic
26. d and write files in the directory 5 6 3 Configuring a Mac OS X SMB Client on an User Submit Computer On a Mac OS X based User Submit Computer you do not need to do anything to enable the SMB Client Once a SMB Server has been properly configured you can connect to the SMB Server with the steps below e Select Finder gt Go gt Connect to Server to open the Connect to Server dialogue window e Inthe dialogue window enter smb lt Name of the SMB server gt lt share name gt Example We have a Shared File Repository located on the machine with the IP 192 168 0 160 SharedRepository which is running as a SMB Server To mount the Shared File Repository from a User Submit Computer select Finder gt Go gt Connect to Server to open the Connect to Server dialogue window In the dialogue window enter smb 192 168 0 160 SharedRepository 42 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 5 6 4 Configuring Mac OS X Based NFS Server The simplest way to configure NFS on an Mac OS X based system is using the NFS Manager utility You can download the NFS Manager utility from http www bresink com osx NFSManager html Using the NFS Manager the steps to configuring an NFS Server on a Mac OS X based system are as follows e Install and start NFS Manager e Select NFS Shares e Click on the Lock and provide administrator s credentials e Click on Add Entry e Select the folder to share e Select Any computer no restrictions e Unde
27. e tasks below and exit Setup V Register EnFuzion Control Root Service y V Start EnFuzion Control Root Service V Start EnFuzion Compute Node EnFuzion V Connect a Web Browser to the EnFuzion Service Figure 3 8 Installation Complete Congratulations You have just set up a one machine render farm Now you will see the EnFuzion Web Interface that shows the status of your render farm as shown in Figure 3 9 lajloje j x J Cluster Nodes Runs Accounting Execution Submit Results Cluster win7 32 10102 Cluster Status Uptime Active Nodes Down Nodes Submitted Runs Completed Runs win7 32 10102 Running 00 00 04 1 0 0 0 Nodes Active Executing Idle Busy Down d 1 d Created Started Stopped Done Failed Figure 3 9 One machine Render Farm Running 11 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE From the EnFuzion Web Interface you can see that e You have 1 Cluster e You have 1 Active Node which is Idle e You have 0 Runs This shows that your One machine Render Farm is active but idling waiting for Jobs to run You can start the EnFuzion3D Desktop from Windows Start gt EnFuaion3D Desktop as shown in Figure 3 10 D EnFuzion3D Te e fs EnFuzion3D Submit View Tools Help em A D 3 3 E A A E 7 User peter win7 32 Root Host localhost 7 EnFuzion Web Compute Nodes DX Active Runs Ex Nodes Total 1 Active 1 Down 0 Active Runs 0 Jobs Waiting 0 Executing 0 Done 0 Failed 0
28. es must be able to communicate with the EnFuzion3D Control Root Computer which they do by running a service called enfStarterSvc exe On all Compute Nodes in Windows firewall settings please make sure to set up the following 4 5 Allow the program lt EnFuzion3D Installation Directory gt EnFuzion Bin enfStarterSvc exe to accept inbound connections and Make sure that this program can use ports 17000 17005 About the Control Root Computer The Control Root Computer is the control and command center of your render farm You must ensure that this computer meets the follow requirements Each render farm has only ONE Control Root Computer The Control Root Computer must be able to run continuously without disruption The Control Root Computer must have a fixed IP address You cannot use DHCP to allocate different IP addresses for the Control Root Computer The Control Root Computer should have at least 100MB of local disk space to hold 20 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 6 Run EnFuzion3D Installer as a Windows Administrator Follow these steps exactly to make sure that you install EnFuzion3D as a Windows Administrator e Identify the user account that your rendering software is installed under login as that user e Copy the EnFuzion download image to this machine e Extract the EnFuzion3D Installer A EnFuzion3D 1 M Right Click gt Extract All e Open the EnFuzion3D Installer Right Click Open e
29. farm you are ready to install EnFuzion3D on more render nodes and artist workstations 4 12 Batch Installation You can batch install EnFuzion3D on many Submit Computers or Compute Nodes at a time using command line scripts This is recommended only after you have successfully installed and tested a minimal three machine configuration Please contact support axceleon com for the batch installation scripts 35 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 13 Troubleshooting Installation Problems Please refer to Section 3 6 Trouble Shooting Installation Problems for how to overcome the most common installation problems More diagnostic tips and solutions for these problems can be found on line at http www enfuzion3D com faq html 4 14 Uninstalling EnFuzion3D This section provides information on how to uninstall EnFuzion3D Please note that there is no need to uninstall EnFuzion3D prior to an upgrade unless Axceleon specifically tells you otherwise To uninstall EnFuzion3D on the User Submit Computers e Choose Windows Start All Programs EnFuzion gt Uninstall EnFuzion To uninstall EnFuzion3D on the Control Root Computer e Choose Windows Start All Programs EnFuzion gt Control Root Utilities Stop EnFuzion Root Service e Choose Windows Start All Programs EnFuzion gt Control Root Utilities gt Unregister EnFuzion Root Service and e Choose Windows Start All Programs EnFuzion gt Uninstall EnFuzion To un
30. install EnFuzion3D on the Compute Nodes e Choose Windows Start All Programs EnFuzion Compute Node Utilities Stop EnFuzion Node Service e Choose Windows Start All Programs EnFuzion gt Compute Node Utilities Unregister EnFuzion Node Service and e Choose Windows Start All Programs EnFuzion gt Uninstall EnFuzion 4 15 Additional Resources for Render Farm Administrators For render farm administrators to have a complete understanding of the EnFuzion software the underlying technology for EnFuzion3D we recommend that you also refer to the EnFuzion Manual for additional information on how to configure EnFuzion 4 16 Next Steps Render farm administrators and artists alike should proceed to the EnFuzion3D User Guide from here 36 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 5 Setting up File Sharing Distributed rendering requires that all the scene files texture files and other project files are stored at a location that is accessible by all Compute Nodes and from all the User Submit Computers Likewise all the Compute Nodes must also be able to access a shared location to store render images If you have at least one remote Compute Node you must first set up file sharing between your User Submit Computer and your Compute Nodes before attempting distributed rendering There are two ways to set up file sharing e Shared File Repository A render farm manager sets up a file server to hold all the scenes project di
31. king on the Run ID of your Run OG crun WE Kaul EnFuzion3D Submit View Tools Help A A gt S ki E G GE 3 A bi po i User admin testPC Root Host 192 168 58 5 ES EnFuzion Web Compute Nodes HX Active Runs ox Nodes Total 1 Active 1 Down 0 Active Runs 0 Jobs Waiting 0 Executing 0 Done 0 Failed 0 Rescheduled 0 E Show My Runs_ Auto Update Active Nodes Executing 0 Idle 1 Unavailable 0 GES oats Se Se TE e H TZ Auto Update Run ID Submission User Status Uptime FinishIn Priority Application Pools Waiting Executi Done Fail Node ID Host Status d TEST PC Idle j D mt gt ii omnieted Run Completed Runs 4 Jobs Waiting 726 Done 2 Failed 0 Rescheduled 20 _ Show My Runs Show Recent Runs V Auto Update RunID a Submission User Status Submitted Completed Uptime Waiting Done Failed Rescheduled Job Li 0000000000 RenderIntro admin Wed May D Wed May 0 00 00 15 0 1 1 0 0 20 i j Sun May D 00 08 31 6 6 0 0 10 0 S Sun May 0 Figure 4 23 View Completed Run Information For more information on how to use the EnFuzion3D Desktop consult the EnFuzion3D User Guide If you cannot successfully render a scene with on your Three machine Render Farm consult the EnFuzion3D User Guide Chapter 2 for tips on how to troubleshoot the distributed rendering process 4 11 Next Steps After you have successfully rendered some scenes with your three machine render
32. l Root Computer and Compute Nodes EnFuzion3D therefore requires administrative privilege to install and execute on the Control Root Computers and Compute Nodes On the Compute Nodes EnFuzion3D must have the same environment settings as the rendering software it calls to do the actual rendering The easiest way to make sure is to install and run EnFuzion3D using the same user as what you used to install and run your rendering software Please make sure to follow the requirements in Table 4 1 to install EnFuzion3D Control Root User Submit Compute Computer Computer Nodes The same user that you Log in as this user to Adnninicirator The normal artist used to install and run install EnFuzion3D user your rendering software e g Maya 19 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 3 Control Root User Submit Compute Computer Computer Nodes User Privilege D SH required to install Administrator Administrator The same user that you EnFuzion3D will Krag Te used to install and run execute as this user your rendering software e g Maya Table 4 1 Installation Requirements Windows User Access Control UAC Settings By meeting the requirements on user privilege settings in Table 3 1 you will be able to run EnFuizon3D with the Windows User Access Control setting at any level 4 4 Windows Firewall Settings EnFuzion3D runs on client server architecture to ensure high performance and scalability All the Compute Nod
33. lhost EnFuaion Web j DX Actve Runs ox i Active i Down O Actve Rune 0 ve Waling 0 Executing 0 Deep Faded 0 Reschedted 0 Show My Bug Auto Update TORG d wen v rer ep Run ID Submission User Status Uptime Fishin Pnonty Application Node fi Host St A d WIN 32 le Randwer Jus softaa Verson C mor mu C a2 C wms C 2014 2015 Completed Runs ox 7 Completed Runs D Jobs Waiting 0 Done 0 Failed 0 Reschecded 0030 0 ShOd000 Bue V Auto Update Cormnend Une Options Runi a Submission User Status Submited Compieted Uptime W Standalone Seen E F r r Intermediate Fie Location rterreeckste Fle Here Standalone Options Render Settings Advanced review Steng Close Welcome to EnFunordD 15 0 Figure 4 20 EnFuzion3D Desktop and Maya Job Submission Interface Step 4 Use a Scene you have successfully rendered before fill out the Job Submission Parameters e Provide Scene Project Directory and Frames information e Click Render Settings as shown in Figure 4 21 to set the Image Directory which is the destination of rendered images Click on Apply to continue e Click Submit to submit the scene l Render Settings Image Directory magnus btrdata applications autodesk maya testdata PE Image Name EE I Add To Je X Resolution Y Resolution rm Tiles in X F E Stitch Tiles in Y Gil Tile Overlap F Figure 4 21 Enter Render settings Each su
34. lick Render Settings as shown in Figure 3 12 to set the Image Directory which is the destination of rendered images Click on Apply to continue e Click Submit to submit the scene G Render Settings Es Image Directory magnus btrdata applications autodesk maya testdata 7 Browse Image Name Camera PR X Resolution Y Resolution Tiles in X Stitch Tiles in Y Tile Overlap der Ces Figure 3 16 Enter Render settings 17 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Each submission corresponds to an EnFuzion3D Active Run with its own Run ID as shown in Figure 3 15 You monitor the rendering progress using the EnFuzion3D Desktop Root Host 1 localhost User is peter magnus kx calhost k E Reconnect X Web Connect Show My Runs Show Recent urs J AutoUpdate Rescheduled Job Length Total Time Figure 3 17 Monitoring Rendering Progress Once rendering completes an Active Run become a Completed Run as shown in Figure 3 16 You can get more information on by clicking on the Run ID of your Run File Submit View Tools Desktop Help RR E PEA e BLS S Si D e BM Root eet 1 localhost User iss peterGmagnus localhost v WR Gezei WW Web Connect DX Active Run Info ax Down 0 ActveRuns 0 Jobs Waltng 0 Executng 0 Done 0 Failed 0 Rescheduled 0 Show My Bure Y AutoUpdste Executing 0 Idle 1 Unavailable 0 e i e e i p e r T J te un ID Submission User Status Upti
35. me Finishin Priority Application cols Wating Executi Done Faded Rescheduled Job Length Total Time S ompletedRuns I Jobs Wating 0 Done Fafed 0 Rescheduled 0 Show My Runs Show Recent urs Autolpdste Bun bi a Submission User Status Submitted Completed Uptime aitan one aile Rescheduled Job Length Total Time 4 re Wed Jan 21 Wed Jan 21 00 01 08 0 5 0 d 00 0043 000107 Figure 3 18 View Completed Run Information For more information on how to use the EnFuzion3D Desktop consult the EnFuzion3D User Guide 3 8 Next Steps Once you have succeeded at setting up a one machine render farm you are ready to set up your production render farm Proceed to Chapter 4 for directions 18 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 Setting up an EnFuzion3D Managed Render Farm This chapter explains the steps to plan set up and configures an EnFuzion3D managed production render farm 4 1 EnFuzion3D Software Installation Order The recommended order to install EnFuzion3D on a render farm is as follows e Install the Control Root Computer first e Add one User Submit Computer and one Render Node e Setup a shared file system for your render farm e Test the Three machine Render Farm to make sure you can successful render some images e Add more User Submit Computers and Render Nodes test as you go 4 2 Computers Users and User Privilege EnFuzion3D uses Windows Services to implement control and communications between the Contro
36. n3D managed render farms Chapter 3 Quick Start Guide Setting up a One machine Render Farm This Chapter describes the quickest way to test drive EnFuzion3D by creating a one machine render farm as described in Chapter 2 Chapter 4 Installing EnFuzion3D on the Windows Platform This chapter describes the steps to install and configure EnFuzion3D on a Windows based production render farm Chapter 5 Setting up File Sharing This chapter describes the steps to set up simple file sharing or a shared file repository for your render farm Chapter 6 Upgrading a Previous Installation of EnFuzion3D This Chapter tells you how to upgrade an existing installation of EnFuzion3D All current users of EnFuzion3D should consult this chapter before performing an upgrade ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 2 Overview of an EnFuzion3D Managed Render Farm This chapter introduces EnFuzion3D concepts and terminology along with a recommended way to set up EnFuzion3D managed render farms 2 1 Key Components of an EnFuzion3D Managed Render Farm A typical EnFuzion3D managed render farm is illustrated in Figure 2 1 User Submit Computers Compute Nodes Shared Repository File Server Figure 2 1 A typical EnFuzion3D Managed Render Farms Key components of an EnFuzion3D managed render farm are e User Submit Computers These are desktop machines that artists use to create scenes You can have as many of these as yo
37. nFuzion3D on those operating systems platforms IMPORTANT Please note EnFuzion3D cannot distribute rendering to an OS platform that is unsupported by your rendering package Please verify that the render package you use is supported on the OS platform that you chose Submit Control Root Windows Windows 7 Windows 8 Yes Windows Server 2008 R2 Linux Red Hat 7 3 Novell SUSE Linux 9 or Newer MAC OS X Y Y 10 7 10 8 or Newer Table 2 1 EnFuzion3D Supported Configurations Yes Yes es Yes Yes es ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 2 3 How does EnFuzion3D work Figure 2 2 below shows a typical multi user server based EnFuzion3D managed render farm 2 EnFuzion3D distributes scenes to the render farm via the Control Root Computer 1 Users submit scenes to EnFuzion3D from User Submit Computers AT E k k S EVY Eg WY m a 3 EnFuzion3D manages rendering on the Compute Nodes 4 Results are stored on the Shared File Repository Figure 2 2 EnFuzion3D Managed Render Farm 2 4 How do I start Start small test as you go Follow these simple steps below to set up your render farm Step 1 Set up a one machine render farm as shown in Figure 2 3 This is the quickest way for you to test drive EnFuzion3D You can skip this step if you are familiar with EnFuzion3D or if you are an experienced render farm manager Figure 2 3 one machine Render Farm Step 2
38. nd mkdir p mnt lt share name gt Example We have a Shared File Repository located on the machine 192 168 0 160 SharedRepository We wish to configure a Mac OS X based Compute Node to mount this repository in the directory mnt SharedRepository Create a mount point with the following command mkdir p mnt SharedRepository Step 2 Create a share description file fstab on the Compute Node Open the Terminal application and type the following command to create the file echo lt server name gt lt share name gt mnt lt share name gt url smb enfuzion lt password gt lt server name gt lt share name gt uid enfuzio n gid enfuzion 0 0 gt fstab Example We have a Shared File Repository located on the machine 192 168 0 160 SharedRepository We wish to configure a Mac OS X based Compute Node to mount this repository in the directory mnt SharedRepository Create an fstab file with the following line 41 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE echo 192 168 0 160 SharedRepository mnt SharedRepository url smb enfuzion enfuzion 192 168 0 160 SharedRepository uid enfuzion gid enfuzion 0 0 gt fstab Step 3 Load the share description to NetInfo with the following command in the Terminal niload fstab lt fstab Step 4 Reboot the machine Step 5 Confirm the SMB mount with the following steps e Login as enfuzion e Navigate to the mnt SharedRepository directory and confirm that you can rea
39. nencvenundacsnanvevuadebusasedsanctovavbdeaveetvadeidenvansootebastavanbiaxseatsaveaceenes 7 3 4 Run EnFuzion3D Installer as a Windows Administrator 7 3 5 Installing a One machine Render Form 8 3 6 Troubleshooting Installation Problems cccccsssecccseseccceseccceesecccsececenecsecusesscesecsseusesseusesssneeseees 12 IZ Fest DAVE Tee ER 17 I NS 18 4 Setting up an EnFuzion3D Managed Render Farm nnnnuvennnnnnnunnnnnnnnnnnennnnnnnnnennnnnnnnnnnnnnnnnnnennnnnnnnnennnnnnnn 19 4 1 EnFuzion3D Software Installation Order sc vsisssacsssscossdeantarzsdensecceelsranavinseousdeensesatdessencedsnceastexbaves 19 4 2 Computers Users and User Privilege scccccsesecccesececeseeccesecccesecsceusesssuseceeesecsseusessausessausecssanses 19 4 3 Windows User Access Control UAC Settings cccccceeccccceeecccececsceeecscsecesececeseseuecssseeessseeessnseess 20 4 4 Windows Firewall Settings ccccseeeccceseccnesecccensesssesecscenseseausecssesecssesestsusecssensessausesssusecesesesssess 20 4 5 About the Control Root COME deene 20 4 6 Run EnFuzion3D Installer as a Windows Administrator 21 4 7 Installing EnFuzion3D on the Control Root Computer 21 4 8 Installing EnFuzion3D on Artist Workstations User Submit Computer 26 4 9 Installing EnFuzion3D on ComputeNodes 27 ar 33 EE 35 TB DNM ee 35 4 13 Troubleshooting Installation Problems ccccseccccsssecccseseccsesecccesececsusesscusecsceseceeausesssusessssecensnses 36 117 UNS ENFUZION
40. ning you re ready to take your one machine render farm for a test drive The simple test here uses Maya 2015 to illustrate how EnFuzion3D works with rendering packages Axceleon provides application plug ins for EnFuzion3D for most popular rendering packages By installing the EnFuzion3D software you have installed all the supported plug ins To get full information on the application plug ins for EnFuzion3D please consult the EnFuzion3D User Guide Follow these steps to take your one machine render farm on a test drive Step 1 Start EnFuzion3D Desktop and Select Maya as shown in Figure 3 11 D 3 EA 9 E g E 3 A G FO User peter Qwin 7 32 Root Host localhost A EFuron Wed OX Ac ve Bug i Active i Down g Actve Rune 0 Jobe Waring 0 Executing 0 Dane 0 Faded 0 Reschedued 0 Show My Burg V Auto Update Actve Nodes Executng 0 Ide 1 Leg gt Te i ei D ste ndate Run 10 Submission User Status Uptime Feeb fn Pnonty Application NodelD Host d WIN 32 le Completed Runs Ox Completed Runs Jobs Waiting 0 Done 0 Fated 0 Reschedded 0050 09 Sh 4000 Aus V Auto Update Run a Submission User Status Submitted Comp eted Uptime Welcome to EnFunondD 15 0 Figure 3 15 EnFuzion3D Desktop and Maya Job Submission Interface Step 2 Use a Scene you have successfully rendered before fill out the Job Submission Parameters e Provide Scene Project Directory and Frames information e C
41. nloads Favorites i Recent PI Specific people Libranes B E E Documents My Videos Saved Searches di Music Games ke Pictures ex Videos Homegroup Figure 5 1 Share Project Directory 5 2 File Sharing with Samba SMB is the default file sharing protocol implemented by Windows Samba is the most commonly used file sharing program that mimics the SMB protocol on Linux and Mac OS X platforms Samba therefore allows machines which run Linux and Mac OS X to share files witn Windows machines using the SMB protocol Most likely you already have Samba and SMB because e Samba is distributed with most Linux and Mac OS X software distributions e You have SMB by default on Windows The instructions and examples in this guide show you how to set up and configure file sharing with SMB and Samba If you wish to use another file sharing protocol such as NFS please contact Axceleon For more information on Samba or to download it please visit www samba org 5 3 Setting up a Shared File Repository Summary of Steps Recall that a typical EnFuzion3D managed render farm consists of the following parts as shown in Figure 5 2 LR p N EnFuzion Control Root Computer EnFuzion User N S Submit Computers SMB Clients EnFuzion Compute Nodes Shared Repository SMB Clients File Server SMB Server Figure 5 2 Typical EnFuzion3D Managed Render Farm 38 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE To set up the Sha
42. odes are the workhorses of your render farm You must install the EnFuzion3D Compute Node software on all of your Compute Nodes Your EnFuzion3D license determines on how many Compute Nodes you can run EnFuzion3D If you are installing EnFuzion3D for the first time we suggest you install only one Compute Node to start adding one Compute Node to the Control Root Machine and the User Submit Machine that you installed earlier will give you the minimal Three Machine Render Farm as shown in Figure 4 12 You can read about the importance of this in Section 2 5 How do I start Control Root User Submit Computer Compute Nodes Computers Figure 4 12 A typical EnFuzion3D Managed Render Farm 27 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 9 1 Installing Rendering Software on Compute Nodes We suggest that you install your rendering software on your Compute Nodes before you EnFuzion3D This way EnFuzion3D will auto detect your rendering applications and auto configure itself accordingly 4 9 2 Installing and Configuring an EnFuzion3D Compute Nodes Follow these steps below to install EnFuzion3D on render nodes Step 1 Create a user account for EnFuzion3D to run on EnFuzion3D requires a user account for it to run on Compute Nodes f you have installed rendering software on a Compute Node then you dont need to create a different user account for EnFuzion3D EnFuzion3D should use the same user account as your rendering software Other
43. ograms EnFuzion3D2Control Root Utilities gt Register EnFuzion Root Service and e Windows Start gt All Programs gt EnFuzion3D gt Control Root Utilities gt Register EnFuzion Root Service 13 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Windows Media Center g Windows Media Player amp Windows Update l f d XPS Viewer 7 Zip peter A Accessories Documents Ji Cygwin D Cygwin X Pictures A Demo Builder 10 Music X EnFuzion3D Desktop L Show Install Log L Show Submission Log x Uninstall EnFuzion3D Games Computer ompute Node Utilities Control Panel Devices and Printers a ET KE Default Programs jeje INregr ter En F zion Root Servic A User Submit Utilities Heip and Ae Figure 3 12 Manually Starting EnFuzion Root Service After you manually start the EnFuzion Root Service you can try re open the EnFuzion Web Interface by opening a browser and type in http localhost 10101 3 6 4 The Web Interface Shows 0 Active Nodes When the EnFuzion Web Interface shows 0 Active Nodes you should first check the EnFuzion Node Service Log to see the reason and then take the appropriate corrective actions To access the EnFuzion Node Service Log file choose Window Start gt EnFuzion3D gt AII Programs Show EnFuzion Node Service Log as shown in Figure 3 13 14 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Lal Windows Media Center KO Windows Media Player T Windows Update SE eg
44. onfig directory o Start the EnFuzion Root Service by choosing Start All Programs gt EnFuzion gt Control Root Utilities gt Start EnFuzion Root service 6 3 Re hosting Your EnFuzion3D Control Root Computer Your EnFuzion3D license file is tied to your EnFuzion3D Control Root Computer or more specifically its IP address If you plan to re host your EnFuzion3D Control Root Computer you will need a new EnFuzion3D license file To obtain a new EnFuzion3D license file for your new server please contact Axceleon at support axceleon com and provide us with the IP address of your new Control Root Computer 6 4 Managing Different Versions of EnFuzion3D You should not mix EnFuzion services from different versions Before installing and running a new version of EnFuzion3D on your render farm you should stop EnFuzion services on all the machines that ran an older version of the software Once you have successfully upgraded your installation you can then start the EnFuzion services associated with the new version of the software 6 5 Start Stop EnFuzion Services On the Windows platform the EnFuzion Root Service consists of two processes enfDispatcher exe and enfeye exe The EnFuzion Node Service has 2 processes enfNodeServer exe and enfStartersvc exe To manually start or stop EnFuzion services on the Windows platform follow the steps below 46 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE EnFuzion Services l Windows Stop Service
45. p Wizard and let you install EnFuzion3D with administrative privilege Step 3 Select the Compute Node Installation option in the EnFuzion3D Setup Wizard as shown in Figure 4 14 i EI x Ip EnFuzion3D Version 15 0 3133 Axceleon Select Components wv Which components should be installed ON Select the components you want to install dear the components you do not want to install Click Next when you are ready to continue Compute Node installation ET CE U D V Compute Node 33 2 MB User Submit Computer 52 9 MB Current selection requires at least 33 9 MB of disk space xa Get Figure 4 14 Install and Configure a Computer Node Step 3 Provide the user account and a password that EnFuzion will use to run on this machine as shown in Figure 4 15 29 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Setup EnFuz 3D Version 150 3133 Axceleon x EnFuzion User Account and Password Which user account can EnFuzion use on this compute node ons Provide EnFuzion with the user account and password to use on this compute node Make sure that the account exists and that it has a valid password NOTICE Setup will not create an EnFuzion user account for you If you have not eu created an EnFuzion user account please create an account before pr User Name admin Password eesse Password Confirmation bees Figure 4 15 Provide User Name and Password for a Compute Node Step 4
46. pted for User Name and Password as shown in Figure 3 4 enter the same user as what your rendering software packages use p Setup EnFuzionsD Version 15 0 3133 Axceleon vr EnFuzion User Account and Password CAR Which user account can EnFuzion use on this compute node Ons Provide EnFuzion with the user account and password to use on this compute node Make sure that the account exists and that it has a valid password NOTICE Setup will not create an EnFuzion user account for you If you have not yet created an EnFuzion user account please create an account before proceeding User Name Password Iessen Password Confirmation farene Figure 3 4 Create User Name and Password for EnFuzion3D ENFUZION3D INSTALLATIO Step 5 Take the default configuration 3 5 Do not change these settings Next to continue with the installation EnFuzion Control Root Host localhost Port for Node Connections 10103 Control Root computer Step 6 Proceed with the installation Provide the network name or address of the Control Root computer Click Notice The default port value 10103 rarely needs to be changed Do not change this value without changing the default EnFuzion service port on the lt Back net gt N AND CONFIGURATION GUIDE settings for Compute Node and Submit Computer as shown in Figure mam eee m C E et EnFuzionsD Version 15 0 3133 Axceleon etu EnFuzionsD Version
47. r Options specify Treat all users as user enfuzion e Leave all other options unchecked e Click OK e Click Activate Changes After you configure the NFS Server test it by doing the following e In NFS Manager select List Remote NFS Shares e Inthe Server field type localhost e Under Folder there should be the shared folder e Under Options it should say mapall enfuzion This completes the configuration of the NFS Server on a Mac OS X based system This configuration must be done once on the machine that is used as a file server 5 6 5 Configuring a Mac OS X Based NFS Client on an EnFuzion Compute Node The simplest way to configure NFS on a Mac OS X based system is using the NFS Manager utility You can download the NFS Manager utility from http www bresink com osx NFSManager html Using the NFS Manager the steps to configuring a NFS Client on a Mac OS X based system are as follows e Open NFS Manager e Verify that the NFS Server is operational e Select Computer List Remote NFS Shares e Enter Server name press List 43 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE e AN NFS share name should be shown e Define an NFS Client e Click on the main NFS Manager dialog e Click on the Lock and enter credentials e Select NFS Entry menu at the top New Connection e Enter NFS Server NFS Share e Unselect Connect as read only folder e Click OK which closes the dialog e Click Activate Changes in the main dialog e Qui
48. rade an existing installation are in Chapter 5 Upgrading a Previous Installation of EnFuzion3D 10 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE File Options View Help Applications Processes Services Performance Networking Users Image Name User Name CPU Memory Description CodeMeterCC exe 32 admin 00 3 700K CodeMet P conhost exe admin 00 1 788K Console conhost exe SYSTEM 00 1 732K Console conhost exe SYSTEM 00 1 708K Console csrss exe SYSTEM 00 1 128K Client Ser csrss exe SYSTEM 00 2 196K Client Ser a iii 00 21 556K Desktop enfDispatcher exe 32 SYSTEM 00 3 532K enfDispat enfeye exe 32 SYSTEM 00 2 524K enfeye enfNodeServer exe 32 admin 00 3 200K enfNodes enfStarterSvc exe 32 SYSTEM 00 1 316K enfStarte XpIOrel ENE Je 00 42 472K Windows jusched exe 32 admin 00 1 868K Java Upd Isass exe SYSTEM 00 3 136K Local Sec Ism exe SYSTEM 00 1 068K Local Ses v J Show processes from all users End Process Processes 52 CPU Usage 0 Physical Memory 6 Figure 3 7 Stop Previously Installed Processes Step 7 Complete the installation by taking all the default values as shown in Figure 3 8 and click Finish x Setup EnFuzion3D Version 15 0 3133 Axceleon Completing the Y EnFuzion3D Setup Wizard Setup has finished installing and configuring EnFuzion3D on your computer Click Finish to perform th
49. re name gt sibfs 4 username enfuzion password lt password gt uid enfuzion gid enfuzion 0 0 Step 3 Mount the new share with the following command 40 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE mount mnt lt share name gt Step 4 Confirm the SMB mount with the following steps e Log in using your normal user login not as the enfuzion user e From a command prompt type cd mnt lt share name gt and confirm that files can be read from and written to the Shared File Repository 5 6 Configuring File Sharing on Mac OS X Based Computers This section provides the information on working with Mac OS X and SMB based file sharing including e How to enable file sharing on a Mac OS X based SMB Server and e How to configure Mac OS X based SMB Clients on User Submit Computers and the Compute Nodes e Howto configure NFS based file sharing on Mac OS X Please see below for details 5 6 1 Configuring a Mac OS X Based SMB Server The steps to configure a Mac OS X based Samba SMB Server for file sharing are beyond the scope of this guide Please contact your systems administrator or contact Axceleon if you have questions on how to set up a Mac OS X based server for file sharing 5 6 2 Configuring a Mac OS X Based SMB Client on an EnFuzion Compute Node To configure a SMB Client on a Mac OS X based Compute Node please follow the steps below Step 1 Create a mount point Open the Terminal application and type the following comma
50. rectories and images directories for all the users and computers on a render farm e Simple File Sharing You manually share your own project directories and images directories so that you can use distributed rendering without a render farm wide Shared File Repository This chapter provides information on how to set up file sharing 5 1 Simple File Sharing If you are just getting started or that you have a small render farm Simple File Sharing is a good choice It can be set up in just a few minutes and it will enable distributed rendering without a render farm wide Shared File Repository which may require a system administrator to set up The concept is very simple all you need to do is to share your entire Project Directory on your own computer including the Image Directory On Windows 7 sharing a folder is easily done with these two simple steps e Locate your Project Directory and Image Directory choose the Share With menu shown in Figure 5 1 e Choose the user from the list of users that your rendering software and EnFuzion3D runs under e Grant that user Read Write rights This enables all Compute Nodes to read Scene files from your shared drive and write the rendered Images back 37 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE J r gt Sam gt Organize v include in library v Share with New folder Tr Favorites amp Nobody 8 WE Desktop Homegroup Read Homegroup Read Write Downloai STA Dow
51. red File Repository you need to do the following e Configure the SMB Server that runs on the Repository File Server machine e Configure the SMB Clients which run on the Submit Computers and the Compute Nodes On heterogeneous render farms the SMB Server and Clients run on different operating systems Please see below for instructions on how to configure SMB Servers and Clients on Windows Linux and Mac OS X platforms 5 4 Configuring File Sharing on Windows Based Computers This section provides the information on configuring Windows machines for SMB based file sharing including e How to enable file sharing on a Windows SMB Server and e How to configure Windows based SMB Clients on User Submit Computers and the Compute Nodes Please see below for details 5 4 1 Configuring a Windows SMB Server for File Sharing Microsoft provides extensive help information on how to set up file sharing on various versions of Windows and Windows Server operating systems Please visit the Microsoft support Web site for information on configuring file sharing 5 4 2 Configuring a Windows Based SBM Client on an EnFuzion User Submit Machine On a Windows based User Submit Computer you do not need to do anything to enable a SMB Client Once a SMB Server has been properly configured verify that you can access shared files in your Shared File Repository by selecting Windows gt Start gt Network on the User Submit Computer 5 4 3 Configuring a Windows Based
52. t please contact Axceleon at support axceleon com 47
53. t NFS Manager The NFS share should appear as another entry in the left column in the Finder This configuration must be done once on each render node 5 6 6 Configuring a Mac OS X Based NFS Client on an User Submit Computer Please contact your system administrator on how to access a NFS server from User Submit Computers 44 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 6 Upgrading a Previous Installation of EnFuzion3D This chapter provides key information on how to upgrade an existing installation of EnFuzion3D All current users of EnFuzion3D should consult this chapter before performing an upgrade Key topics addressed in this chapter are e Planning an EnFuzion3D upgrade e Updating your EnFuzion3D license file e Re hosting your EnFuzion3D Control Root Computer e Managing different versions of EnFuzion3D e Start stop EnFuzion services e Upgrading your EnFuzion3D installation 6 1 Planning an EnFuzion3D Upgrade To plan for an orderly upgrade of EnFuzion3D on your render farm please note the following recommended steps e Stop EnFuzion services associated with your current version of EnFuzion3D For more detail on this please see the section below titled Start Stop EnFuzion Services e Back up your current EnFuzion3D installation directory e tis not necessary to uninstall an older version of EnFuzion3D before updating it e Install a new version of EnFuzion3D on the EnFuzion Control Root Computer all the User Submit
54. tartup bat e It must be placed in the lt EnFuzion3D Installation Directory gt bin directory on each Compute Node e The script must conform in syntax to a Windows batch file You can find an example startup bat in the lt EnFuzion3D Installation Directory gt bin directory Please modify this file to adapt it for your environment After you make any changes to a startup bat file on a Compute Node you musi restart the EnFuzion Node Service on that Compute Node To do this e Choose Windows Start All Programs gt EnFuzion gt Compute Node Utilities from there e Stop EnFuzion Node Service e Register EnFuzion Node Service and finally e Start EnFuzion Node Service 32 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE 4 10 Test Drive EnFuzion3D If you are installing EnFuzion3D for the first time and you have followed the steps as we suggested above by now you have a Three machine Render Farm Follow the steps in this section to take your miniature render farm on a test drive Our simple test here uses Maya 2015 to illustrate how EnFuzion3D works with rendering packages Axceleon provides application plug ins for EnFuzion3D for most popular rendering packages By installing the EnFuzion3D software you have installed all supported plug ins To get full information on the application plug ins for EnFuzion3D please consult the EnFuzion3D User Guide Follow these steps to take your three machine render farm on a test drive Step 1 Setting
55. u need Your EnFuzion3D license does not limit the number of these computers e Control Root Computer For optimal performance it is recommended that you dedicate one machine per render farm to serve as the Control Root Computer This computer controls all EnFuzion3D activities on the render farm This machine is also where your EnFuzion3D license file is installed e Compute Nodes These are the worker machines dedicated or shared that make up your render farm and do the rendering Your EnFuzion3D license file sets the maximum number of the Compute Nodes you can have ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE e A Shared Repository File Server All your rendering project files must be stored in a shared file repository that is accessible by all the Compute Nodes and by all the User Submit Computers The Shared Repository File Server is the computer that stores the repository of project files You can have one or more Files Servers and Shared File Repositories on an EnFuzion3D managed render farm 2 2 Mixed OS Render Farm Support EnFuzion3Dsupports render farms with machines running different operating systems Tested and supported components are indicated as Yes in the table below You can freely mix these components on your render farm e g submit scenes from Windows machines to render nodes that run Linux Please refer to the installation guides for Linux and Mac OS X users for instructions on how to install and configure E
56. ubmit Computer Step 3 When prompted to provide EnFuzion Service Host address as shown in Figure 4 11 provide the Fixed IP Address of the Control Root Computer of your render farm 26 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE x Setup EnFuzionsD Version 15 0 3133 Axceleon Configure User Submit Computer Vs What is the address of the EnFuzion service on the Control Root computer d lt Provide the network name or address of the Control Root computer Click Next to continue with the installation EnFuzion Service Host TY EnFuzion Service Port 10102 Notice The default port value 10102 rarely needs to be changed Do not change this value without changing the default EnFuzion service port on the Control Root computer as rea Ceres Figure 4 11 Provide Control Root Computer address to a User Submit Computer Step 5 Continue and finish installation by clicking on Next This completes the steps to install EnFuzion3D on an artist workstation 4 8 1 What to do next If you are installing this for the first time proceed to the next section to add one Compute Node to create a Three Machine Render Farm You can read about the importance of this in Section 2 5 How do I start After you have successfully rendered some scenes on your Three Machine Render Farm you can then go ahead to install EnFuzion3D on all the machines on your render farm 4 9 Installing EnFuzion3D on Compute Nodes Compute N
57. wise follow instructions from Microsoft to create a new user account Please remember to install rendering software using the same user afterwards The user account that EnFuzion3D uses on the Compute Node must have administrator privilege You must do this for every Compute Node on your render farm Please complete this step before installing EnFuzion3D Step 2 Run EnFuzion3D setup program as an administrator by following these steps exactly e Log in as the user discussed in the section above e Copy the EnFuzion download image to this machine e Extract the EnFuzion3D Installer dows s2bit 2 0150426 2241 W Right Click gt Extract All e Open the EnFuzion3D Installer EnFuzion3D 1 5 0 3133 Win dows 32bit 2 0150426 2241 58 Right Click Open e Run the EnFuzion3D Installer using Run as administrator as shown in Figure 4 13 28 ENFUZION3D INSTALLATION AND CONFIGURATION GUIDE Li Run as administrator a ge WI m gt EnFuzion3D 15 0 3133 Windows 32bit 20150426 224158 7 Zip p Pindo Organize v Include in library v Share with e Burn New folde Share with gt 2 Name i D Restore previous versions di downloads 2 ke di Licenses 5 Send to gt E Desktop __ AGREEMENT tt A 8 Downloads DEAD RAL Go 4 Cut E Recent Places S Setup EnFuzion3D 15 0 3133 exe 4 Copy x Create shortcut Delete Rename Properties Figure 4 13 Install EnFuzion3D as Windows Administrator This will open the EnFuzion3D Setu
58. xit Setup V Register EnFuzion Control Root Service d Start EnFuzion Control Root Service EnFuzion Figure 4 7 Register and Start EnFuzion Root Service Step 7 Open the EnFuzion Web Interface to verify that your Control Root Computer is running To do this e Open a Web browser and enter http lt IP Address of your Control Root Computer gt 10101 e From the EnFuzion Web Interface click on Cluster The Status should show Running upon a successful installation See Figure 4 8 e From the Windows Task Manager you should see two new EnFuzion processes running which are enfDispatcher exe and enfeye exe Cluster Summary x Wach lt Cc localhost 10101 summary htm ds Home Cluster Nodes Runs Accounting Execution Submit Results Cluster win7 32 10102 Cluster Status Uptime Active Nodes Down Nodes Submitted Runs Completed Runs win7 32 10102 Running 00 00 15 0 0 0 Nodes Active Executing Idle Busy Down Nodes 0 0 0 0 Runs Created Started Stopped Done Failed Figure 4 8 The EnFuzion Web Interface If you cannot start the EnFuzion Web Interface or that the Cluster Status is not shown as Down please refer to Troubleshooting Installation Problems for troubleshooting tips You should not proceed further until you can get EnFuzion Root Service running 4 7 1 What to do next Once you have successfully installed a Compute Root Computer you can move on to add one User Submit Computer and one Compute Node 25
Download Pdf Manuals
Related Search
Related Contents
Manual de Montagem CZ 505_506_507_508_512.dft Copyright © All rights reserved.
Failed to retrieve file