Home

User Manual - BC Group International Inc.

image

Contents

1. INTRODUCTION Congratulations on your purchase of the BC Biomedical Model PLA Pacer Load Adapter The PLA works with the BC Biomedical Defibrillator Pacemaker Analyzer to provide a range of simulated patient loads for transthoracic or external invasive pacemakers A total load resistance of 500 1000 3000 5000 6000 10000 or 15009 may be selected to meet the requirements of various pacemaker manufacturers The PLA includes 1 protective electrode cover black 1 banana test lead red e 1 adapter 2mm female to 4mm male e 1 adapter 4mm female to 2mm male CAUTION NOTE WARNINGS Discharge of high energy defibrillator pulses through the PLA will damage the PLA load resistors The PLA is designed for a maximum RMS current of 50mA at any input This is equivalent to a rectangular current pulse of 200 mA with a pulse width of 20 mS and a rate of 180 pulses per minute 3 pulses per second To calculate the RMS the square root of the mean of the square current in a rectangular pulse waveform with a pulse amplitude of 0 2 A a pulse width of 20 mS and a period of 333 mS The square of the amplitude is 0 2 0 2 0 04 the mean average of the squared waveform over one period is 0 04 20 333 0 00240 and the square root of this average is 0 049A OPERATION WITH DA 2000P and DEFIBRILLATOR WITH TRANSTHORACIC PACEMAKER Additional Equipment Needed 2 alligator clips P N 48009
2. 1 2mm female to 4mm male banana jack 1 banana test lead 1 Attach the PLA to either paddle electrode of the DA 2000P by placing it on top of the electrode See Figure 1 2 Cover the other DA 2000P electrode with the black protective cover that is included with the PLA This cover is a safety feature designed to limit contact with the exposed electrode 3 Cut the two pacer pads off the set of pacer leads from the defibrillator and discard the pads 4 Attach the two alligator clips to the two banana test leads 5 Connect the alligator clips to the cut ends of the defibrillator pacer leads NOTE A more permanent set of test leads can be made by adding banana plugs to the ends of cut off pacer pad cables 6 Connect one of the banana plugs to the desired load impedance on the PLA and connect the other banana plug to the other electrode through the safety cover 7 Follow the DA 2000P User s Guide instructions for pacemaker testing T Defibrillator Test leads Cut off pacer pads Cover Paddle electrodes Figure 1 Connecting PLA 2000 and Defibrillator IV SPECIFICATIONS Input Connections Output Connections Load Selection Load Impedance Enclosure Seven banana jacks provide input connections Inputs are labeled with the total load impedance in ohms The banana jacks mate with standard size banana plugs 0 166 diameter by 9 16 long The output of the L
3. 0 242 8428 between 8 00 AM and 4 30 PM Central Standard Time CST Monday through Friday except holidays Whichever method of contact you choose please provide the following information Product name and serial number Revision level of your software The specific steps which reproduce your problem Any error codes displayed on screen descriptions of error codes are available in Appendix A A daytime phone number fax number and or email address if available Your name company
4. User Manual PLA Pacer Load Adapter Biomedical 9 A Unit of Grout Notices Copyright 2000 BC Group International Inc 3081 Elm Point Industrial Dr St Charles MO 63301 USA Phone 314 638 3800 Toll Free 888 223 6763 Fax 314 638 3200 E mail sales bcgroupintl com Internet www bcgroupintl com All Rights Reserved This publication is protected by copyright and all rights are reserved No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of the product manufacturer Restrictions and Liabilities Information in this document is subject to change and does not represent a commitment by BC Group International Inc BC Group Changes made to the information in this document will be incorporated in new editions of the publication No responsibility is assumed by BC Group for the use or reliability of software or equipment that is not supplied by BC Group Trademarks BC Biomedical and PLA2000 are trademarks of BC Group International Inc CONTENTS INTRODUCTIONS 2 WARNINGS nianse JOPERA WARRANTY TECHNICAL
5. oad Adapter connects to a paddle input electrode of the DA 2000P The load provided by the Load Adapter is selected by connecting the input signal to the appropriate input jack When the Load Adapter is attached to the DA 2000P the user is able to select an input load impedance from the following values 500 1000 3000 5000 6000 10000 and 15000 The 500 selection is the load impedance of DA 2000P itself The load resistances have a tolerance of 1 a temperature coefficient of 100ppm C and low enough inductance to not interfere with the measurements being performed The enclosure is made of a nonconductive material It connects directly to one of the DA 2000 paddle inputs and covers the paddle input to prevent accidental contact by the user V WARRANTY This Warranty is limited and applies only to new products except for computer based software which is covered under a separate Warranty Policy manufactured by BC Group International Inc BC Group International Inc makes no warranty whatsoever regarding the condition of used products BC Group International Inc warrants the instrument hereinafter collectively referred to as Products or Product for a period of one 1 year from the original purchase date against defective materials or workmanship This Warranty is limited to the original purchaser the and cannot be assigned or transferred All claims under this Limited War
6. of five 5 years after the manufacturer of any equipment has been discontinued Parts shall include all materials charts instructions diagrams and accessories that were furnished with the standard models THIS WARRANTY CONTAINS THE ENTIRE OBLIGATION OF BC GROUP INTERNATIONAL INC AND NO OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY ARE GIVEN PURCHASER AGREES TO ASSUME ALL LIABILITY FOR ANY DAMAGES AND OR BODILY INJURY OR DEATH WHICH MAY RESULT FROM THE USE OR MISUSE OF ANY EQUIPMENT OR INSTRUMENT BY THE PURCHASER HIS EMPLOYEES AGENTS OR CUSTOMERS OTHER THAN THE EXPRESS WARRANTY CONTAINED HEREIN WE SHALL NOT BE RESPONSIBLE FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND THIS WARRANTY SHALL NOT BE CHANGED OR MODIFIED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF AN OFFICER OF BC GROUP INTERNATIONAL INC THIS WARRANTY IS VOID UNLESS THE PURCHASE REGISTRATION CARD HAS BEEN COMPLETED AND MAILED TO US WITHIN TEN 10 DAYS OF PURCHASE VI TECHNICAL SUPPORT BC Biomedical s Pacemaker Load Adapter is backed by a superior support staff If the PLA ever fails to work perfectly please contact the Technical Support Staff Written Communications You may write a letter with your comments and send it to BC Biomedical BC Group International Inc 3081 Elm Point Industrial Dr St Charles MO USA 63301 OR E mail sales bcgroupintl com Phone Support You can telephone the Technical Assistance Center at 314 638 3800 or 1 80
7. ranty must be made in writing to BC Group International Inc Attention Service Department Purchaser must ship the Product to BC Group International Inc postage pre paid BC Group International Inc shall either repair or replace with new or like new at its option and without cost to the Purchaser any Product which in BC Group International Inc s sole judgment is defective by reason of defects in the materials or workmanship This Warranty is VOID if the Product has been damaged by accident or misuse or has been damaged by abuse or negligence in the operation or maintenance of the Product including without limitation unsafe operation operation by untrained personnel and failure to perform routine maintenance This Warranty is VOID if the Product has been repaired or altered by persons not authorized by BC Group International Inc or if the Product has had the serial number altered effaced or removed This Warranty is VOID if any of the Products has not been connected installed or adjusted strictly in accordance with written directions furnished by BC Group International Inc Batteries fuses lightbulbs and other consumable items used in any of the Products are not covered by this Warranty Software utilized in conjunction with any of the Products is not covered by the terms of this Warranty but may be covered under a separate BC Group International Inc software warranty We will continue to stock parts for a maximum period

Download Pdf Manuals

image

Related Search

Related Contents

米穀水分計ライスタf5 取扱説明書 Rev.0201  Quick Guide Operating Instructions  AEG 1600 Washer User Manual  FERNGESTEUERTE AUSBILDUNGSHALSBÄNDER FÜR HUNDE  Réfrigérateur Fridge Kühlschrank  ACME A105/9 mobile device charger  Cómo imprimir sin computadora  Service Manual - Appliance Factory Parts  Samsung Galaxy Ace 2 Bruksanvisning  Sony VAIO VPCEB25FX  