1. Screw Position lt 800ppm A C Yellow LED Display A 800 1200ppm J Terminal Block A D Red LED Display J gt 1200ppm K Power Inlet A ais L RJ 45 Socket ra x y f E Mode Button For factory use A DO only BZ F Up Button M Gas Entry Hole d2 G Down Button o W RJ 45 Socket including the RS232 and analog output Power Inlet is used for factory testing only and when using 6VDC the LCO and LVO will not work LCD Display Symbol Symbol Meaning Description C02 Concentration PEM The current CO2 concentration in your household Parts Per Million Ventilation Rate cfm p Cubic Feet Minute Person The Present Cubic Feet Minute Ventilation for one person Ventilation Rate L P S Liter Person Second The Alarm Setting Icon the factory setting with The Current Liter Second Ventilation Rate for one person To calibrate the CO2 sensor when the accuracy Calibration deviates from the actual CO2 concentration CALIBRATING The 1st Alarm Level Relay status will invert after CO2 level exceeds Alarm Level 1 AL1 The Buzzer and Yellow LED will work after CO2 level exceeds AL1 The 274 Alarm Level The St r and Red LED will work afftee62 level exceeds AL2 AL 2 Alarm Level 2 To Recover Factory Setting to cancel the Recover Factory Setting atomized setting ReFactSet Safety Instruction Warning Your safety is very importa
2. Repair Do not attempt to repair the product or modify the circuitry by yourself Please contact with our local dealer time or a qualified repairman if the product needs servicing 3 Calibration Please observe the calibration operation to make sure the accuracy for the devices when it s necessary 4 Air diffusion tThe ventilation slots on the housing are designed for CO2 diffusion so these ventilation slots should not be blocked EVEN E ele C e Step 1 Release the screw from the device take the front cover off Step 2 Release the four screws from the backcover take the CO2 board from the backcover Step 3 Using the screw to fix the backcover to the current outlet let the wires come out of the hole Please pay attention to the terminal block connection data information Step 4 Re assembling the CO2 board by screw to the back cover Step 5 After finishing the terminal block wire connection Press the front cover to the LCD display RJ45 Interface amp Wiring Connection Caution The RJ45 socket is only for factory calibration use not for LAN it was covered by plastic cover the incorrect RJ 45 connection will have the risk of circuit damage or irreparable damage to devices COMMON LVO LCO RS232 DGND but COMMON CANNOT connect to power GND 1 Relay Norm Open 2 Relay Common 3 24
3. VAC GND 4 24vac RX TX LCO LVO COMMON NULL NULL NULL onoaonfh whnrh Figi RJ45 Interface Side view Typical Wiring Diagrams Fig 2 Wiring Connection mA 18 26 VAC RMS 18 36 VDC LCO Linear Analog Current Output LCO Linear Analog Current Output LVO Linear Analog Voltage Output LVO Linear Analog Voltage Output These terminals are only for output they CANNOT connect to any power source The terminal 5 8 CANNOT connect to the terminal 3 24VDC GND otherwise The device will be burn out Customized Settings When the power has been connected The CO2 monitor will begin to work In order to meet you personal requirement it is advisable to set up the customizing parameter Warm Up It lasts approximately 1min before WARM UP disappears all MODE functions will not response during warm up Ventilation Rate MODE BUTTON Pa ra M M 1 Press the MODE the speaker icon flashes simultaneously 2 Press ENTER use up down to select the on off 3 Press ENTER again to save the setting Note The factory setting with alarm is buzzer off user can set the alarm on off according to alarm function instruction Setting the Calibration mode 1 Press the MODE the CALI icon flashes 2 Press the ENTER CALI show on the display 3 Adjust the display to the ambient CO2 value by up down button 4 Press
4. Wall Mount CO2 Monitor Operating Instructions Model ZGw08VRC Product Overview Thank you for selecting this CO2 wall mount monitor This product was developed to detect the presence of CO2 in the ambient air and help people to take care of the Indoor Air Quality The compact device is designed for use in HAVC in the building The demand controlled ventilation in the building also the greenhouse with the CO2 concentration control By using the CO2 monitor as the indicator it can easily get the current CO2 concentration together with the ventilation rate And then adjust the ventilation to the comfort condition automatically by the setting data So the over ventilation of the building can be reduced and the energy can be saved The CO2 monitor can be widely used in the office building green house school exhibition shopping mall The CO2 monitor is easy to use and has many features Dual Beam NDIR Non Dispersive Infrared technology used to measure CO2 concentration Three different LED display show the current Indoor Air Quality situation Linear analog output 0 10V Voltage 4 20mA Current and Relay output based on CO2 Level Reliable Sensor provides long term calibration stability The visual and audible alarm function can be adjustable by user Mounting bracket with terminal block provides quick easy installation Operation Instruction Back view Front view A Main LCD Display B Green LED Display H Enter Button
5. nt to us To ensure you use your product correctly and safety we would like to your attention to read those warning and the User Manual before using the product These Warning provides important safety information and should be observed at all times 1 Please take the devices lightly do not subject the product to impact or shock Otherwise this may cause the accuracy drift 2 Do not immerse the product in water 3 Please pay attention to the terminal block connection instruction the wrong mode of operation or opposite installation will destroy the circuit of the devices 4 Do not touch the exposed electronic circuitry of the device under any circumstances Keep the circuit is close during installation As there is the danger of electric shock 5 Please keep the devices away from children touch to avoid the danger or the accident 6 Do not keep the product under the hot and moisture environment Keep the product away form the heat source or near water 7 Please ensure the screws are fixed on the wall tightly Do not let the screws approach or close to the surface of PCB board during installation It has the risk of circuit damage or irreparable damage to devices Caring for product To make sure you receive the maximum benefit from using this product please observe the follow guideline 1 Cleaning disconnect the power before clean Use a damp cloth do not use the liquid cleaning agent such as benzene thinner or aerosols 2
6. of ZGw08VRC Use 380 420ppm as the standard reading Calibrate the device by the Cali Mode instruction W Method C use standard CO2 in the bottle Pump the standard CO2 gas 0 1000ppm flux 0 1 0 2 liter min into the CO2 monitor from the Gas Entry Hole waiting about 2 3min Calibrate the device by the Cali Mode instruction Fault Codes amp Troubleshooting Guide This section includes a list of Frequently Asked Questions for problems you may encounter with the ZGwO08VRC CO2 Monitor LCD Fault Description ew of the fault Suggested Actions This error will disappear when the temperature returns to the range between 0 C and 50 C 32 F to 122 F Please unplug the AC adapter and reconnect it If the Er4 always appears please contact with the local dealer The ambient temperature has exceeded the temperature range 0 C to 50 C 32 F to 122 F some wrong measurement or the sensor has exceeded its expected life Please unplug the AC adapter and reconnect it If the Er5 Er6 always appear please contact with the local dealer 4 Er7 Internal Data Transmission Error Please unplug the AC adapter and reconnected it Radiant Innovation Inc Http www ZyAura com ZyAur a 1F No 3 Industrial East 9 Road Science Based Industrial Park se HginChu Taiwan 300 ye ACE BS Ref No 032013 EEPROM System Problem
7. or 90 of step change Warm Up Time lt 60 seconds at 22 C Sound Alarm 70db 10cm Zone LED Display Green lt 800ppm Yellow 800 1200ppm Red gt 1200ppm Power Supply 18 26VAC RMS 50 60Hz or 18 36VDC Double insulated Full wave rectifier no polarity input Linear Voltage Output 0 10VDC Linear Current 4 20mA Max Load is 500 Ohm Output Max Load is 400 Ohm while power supply lt 20 VDC Relay Output 30VDC or 250VAC max 2A SPST Normally Open Operating ane se E Operating Humidity peen 0 95 RH non condensing Storage Temperature 20 C to 60 C 4 F to 140 F Ey eT een Calibration Notice Before calibrating you need standard gas or semi standard gas there are 3 methods to get standard gas W Method A use CO2 in office building Use two Meters One is the device for calibration The other one is a calibrated new one Use ambient room gas for calibration in office waiting at least 10min until the CO2 reading doesn t change Notice user must not breathe toward the CO2 monitor CO2 from the user will affect the reading of CO2 monitor Use the reading of the new device as the standard Calibrate the device by the Cali Mode instruction Hi Method B use CO2 outsides Use ambient room gas for calibration outsides waiting at least 10min until the CO2 reading doesn t change Notice user must not breathe toward the CO2 monitor CO2 from the user will affect the reading
8. the MODE morn than 10 sec CALI flashes Calibration will be done automatically after about 8 minutes and LCD will display Pass or Fail If it shows Fail please try again Setting the Alarm parameter Mode 1 Press the MODE the speaker icon flashes simultaneously 2 Press ENTER Using the Up Down to set the parameter 3 Press the ENTER again to save the data Remark There have AL1 amp AL2 when you press the mode You can set the two different levels on your opinion The resolution is 100 ppm per times Using the ReFactSet Mode Ci PRESS ENTER BUTTON at M scan 1 Press MODE The ReFactSet flashes simultaneously 2 Press ENTER Using the Up Down to select the No Yes 3 After the slecting Press the ENTER to save the changes Remark If the user setting the data or calibrate the sensor wrongly You can use the ReFactSet Recover the factory Setting to come back the factory setting data Specification Method Dual Beam NDIR Non Dispersive Infrared Sample Method Diffusion or flow through 50 200 ml min Mi Performance CO2 Measurement Range 0 3 000ppm display Display Resolution 1ppm at 0 1 000ppm 10ppm at 1 001 3 000ppm Accuracy 75ppm or 5 of reading whichever is greater Repeatability 20 ppm 400ppm Temperature Typ 0 2 of reading per C or 2 ppm per C whichever is Dependence greater referenced to 25 C Pressure r 0 13 of reading per mm Hg lt 2min f