Home
Brochure - GN Otometrics
Contents
1. a comprehensive user friendly VNG ENG solution based on years of practical experience and the largest installed equipment base Moreover we work closely with the leading balance experts to offer superior product training greatest possible ease of use and the most accurate test results ICS Chartr 200 BALANCE Integrated Irrigation with the new ICS AirCal ICS AirCal integrates the irrigation function with Otometrics VNG ENG solutions enabling you to stay close to the patient while accurately completing the caloric test battery e Small footprint Otometrics VNG ENG solutions can be stacked with ICS AirCal e Direct communication with Otometrics VNG ENG solutions Irrigation with the ICS AirCal provides a modern choice for gold standard caloric irrigation It combines the convenience and patient comfort of air with the precision of water irrigation enabling you to do caloric testing with confidence With no water to catch the entire irrigation process is easier for the clinician and more pleasant for the patient gt See more at www otometrics com aircal Technical Specifications Interface USB to PC Power supply AC DC adapter Input 100 240 VAC 50 60 Hz 700 mA Output 15V DC 2A Optional isolation transformer 115 230 VAC 10 5 A System capabilities Inputs VNG 2 eyes 4 channels full binocular testing simultaneous collection of signals from both eyes Inputs ENG 2 or 4 channels CMR ratio gt 100 dB
2. at 50 60 Hz Channel Frequency Response 12dB octave low pass filter with a cutoff frequency of 35 Hz Input Impedance Channel 1 gt 5 5 Mohms Channel 2 3 4 gt 8 Mohms Coupling DC response Resolution 0 1 typical horizontal and vertical Linearity 1 full scale horizontal 1 2 full scale vertical Sampling rate Full 60 Hz for all tests Eye tracking 30 horizontal 30 vertical Software Windows graphical user Interface high performance analysis software database storage of test data sophisticated patient and test data management Additional capabilities See through for external targets vision denied for testing in complete darkness ICS Chartr 200 hardware 5 Ibs 7 oz 2 7 kg Lightbar 5 Ibs 3 oz 2 38 kg Binocular Goggles 15 2 oz 430 g Dimensions ICS Chartr 200 hardware 1 65 x 13 7 x 11 3 4 2 x 34 8 x 28 7 cm Lightbar with ends closed 4 63 x 35 75 x 4 75 11 8 x 90 8 x 12 1 cm PC requirements Processor Pentium M or Pentium 4 RAM Minimum 1 GB RAM Bus support USB 2 0 OS Microsoft XP Professional Service Pack 2 Vista Business or Windows 7 Professional 32 or 64 bit CD drive CD R AW Display resolution Minimum screen resolution of 1024 horiz x 768 vert at 96 dpi At large size 120 dpi setting minimum resolution is 1280 horiz x 960 vert Display color 32 bit color The ICS Chartr 200 system comes with ICS VNG ENG software lightweight lightbar VG40 goggles re
3. Balancing accuracy and great efficacy VNG ENG ICS Chartr 200 The solution for quality care ICS Chartr 200 provides you with a comprehensive solution based on years of practical experience We have worked closely with the leading balance experts to ensure the greatest possible ease of use and the most accurate test results VNG ENG or both The ICS Chartr 200 provides a comprehensive test battery for diagnosing a wide range of balance and dizziness disorders allowing you to care for your patient from diagnosis through treatment Whether you choose Videonystagmography VNG or Electronystagmography ENG you will benefit from a complete portable easy to use system Both VNG and ENG are primary diagnostic tools for investigating the source of a vestibular disorder VNG directly records and measures eye movements and offers the following advantages e Ability to see the patient s eyes at all times e Video recording of the eyes which assists with diagnosis e No drift in the tracings e Reduction of disposable supply cost ENG 2 or 4 channel measures eye movements by indirectly recording the cornea retinal potential trom the eyes and has the advantage of testing some patients who cannot be tested using VNG VNG and ENG complement each other assuring that the clinic does not have to turn away patients in need of vestibular testing The Chartr 200 offers a shared database for VNG and ENG The industry leader
4. The Chartr Experience includes far more than just industry leading hardware and software We view each ICS Chartr 200 customer as a partner in advanced vestibular testing With the high level training and support offered our reputation as the industry leader is both earned and unmatched Superior Hardware Dedicated hardware assures a smooth stimulus presenta tion and accurate data collection Ranger on the lightbar ensures that the patient is always the right distance from the stimulus providing the clini cian with on going feedback of the patient s position Data collection is buffered in hardware giving the computer the freedom to perform real time analysis of the data without lagging behind or dropping data points Integrated ICS irrigators offer ease of use and accuracy through automatic temperature switching Sleek and portable The lightweight and flexible design of the lightbar completes the portable ICS Chartr 200 solution Tools that ease your workday Following in the steps of pioneering balance clinics you will benefit from the advantages of our innovative VNG ENG system Using the familiar Windows user interface our integrated software shared databases and common reporting templates are quick to learn and easy to use Time saving features The ICS Chartr 200 software offers time saving options Once data collection is complete the data will be saved analyzed and displayed automatically Au
5. mote control ENG cable optional irrigator cable USB cable 20ft power supply ENG external loop back test fixture optional installation setup guide printed user manual CD and under Help in the software and ICS support material Lightbar stand and carrying case are optional Watch Dr Kamran Barin s video Sign up for Dr Kamran Barin s guides on caloric testing VNG ENG course DoT ee oe ie ed Air Catonc Phenulsbee Specifications are subject to change without notice Copyright GN Otometrics ASAI Ray Beara NTE O A ANNE gt otometrics com caloricguides gt otometrics com vngcourse f facebook com otometrics twitter com otometrics jm youtube com otometricsTV GN Otometrics Europe 45 45 75 55 55 info gnotometrics dk _ GN Otometrics North America 1 800 289 2150 sales gnotometrics com ot O mM eT r C S www otometrics com MADSEN AURICAL ICS
6. n of caloric results is based on the physiology of the vestibular responses and has been evaluated in a large patient population The cutoff values for different caloric test and static position test parameters such as unilateral weakness nystagmus intensity and others are fully customizable so that each laboratory can use its own normative limits When the results of the data are not explainable by any physiology or pathophysiology of the vestibular system the Interpretation Assistant guides the clinician with suggestions Interpretation of these results is presented in clear text to assist in the patient counseling and the text can be transferred to the patient report The Interpretation Assistant was developed in collaboration with Kamran Barin Ph D Kamran Barin Ph D is a recognized expert with an extensive record of publications and experience in the area of vestibular testing The default normative values were developed in collaboration with Dr Barin His studies have played a vital role in creating the unique algorithm that forms the foundation for both the interpretation assistance and the test capability Dr Barin has taught seminars worldwide in different areas of vestibular assessment and rehabilitation Learn more about Dr Barin s ICS VNG ENG courses at www otometrics com vngcourse Balance clinics require comprehensible solutions for diagnosing dizzy patients The ICS Chartr 200 provides you with
7. r ise E deg oor Ce ee ee m ae a ea E nrag T aa a a TE Er iim M ee ee The Interpretation Assistant is an integral part of the ICS Chartr 200 system It offers you assistance with the interpretation of both static positional tests and caloric tests On screen PODS and Butterfly The ICS Chartr 200 displays caloric PODS and Butterfly graphs on a single screen and page Kamran Barin Ph D Integrated analysis developed by professionals For more than 25 years ENG VNG systems developed by ICS have been synonymous with reliable data collection and quality The Chartr software platform first developed by thought leader Dr Charles Stockwell and continuously refined by Dr Kamran Barin is the gold standard in efficient work flow and data analysis VNG Recording Options The VNG system offers several options for recording the patient s eye movements e For conjugates eye movements the average movements of right and left eyes are recorded e For disconjugate eye movements independent movements of each eye are recorded simultaneously e For special cases monocular movements of the selected eye are recorded All three options can be easily accessed using the binocular VG 40 goggles 3 easy to use toolbar icons and test protocol menu Interpretation Assistant After completing the static positional or caloric tests the Interpretation Assistant provides assistance with interpreting the test results The validatio
8. to fixation light allows the user to set a time when the fixation light will automatically turn on and off during caloric testing Caloric countdown timer will display how long it has been since the last caloric test was completed Integrated irrigation Make caloric testing even easier when using the integrated ICS air or water irrigator e Selecting the caloric protocol will select the correct temperature on the irrigator e Using the trigger button on the irrigator handle or the foot switch will start the countdown timer and VNG ENG tracing simultaneously Comprehensive reports Detailed customized reports are automatically created in a format that is easily understood by physicians audiologists and other professionals Concise organized reports stored in one common database make it easy to share data Digital video clips for fast review Easy recording review and transfer of digital video sequences allow you to share information with colleagues and even send video files as e mail attachments Patient s eyes and buttons to start and stop the recording are visible during the entire data collection Patient care with a personal touch Easy access foot switch allows patient data collection while staying close to your patient The convenient remote control lets you operate the software from a distance so you can maintain personal contact with your patients ee ee ee a ie te ee i ami
Download Pdf Manuals
Related Search
Related Contents
Manual Panasonic CU-3KE19NBU Service Manual 施工説明書 ( ) 1 安全上のご注意 2 各部のなまえ GBC 4500LM AirVideo-2000 User`s Manual - Airlivecam.eu Certification Guide & Install Manual Avaya 518-100-701 User's Manual Productos Kelmer Samsung 2043WM Manual de Usuario Samsung E2230 Korisničko uputstvo Copyright © All rights reserved.