1. 4 noks com 15 06 2015 05T408021R1 3 E4U E4U S Quick Guide EN ELIOS4YOU amp ELIOS4YOUSMART uICcK Guide The Elios4you family of products are wireless devices designed to monitor and manage single phase photovolatic installations via the Elios4you APP Maximum monitored power 10kW The transmitter measures the energy generated of the PV plant exchanged with the grid the household consumption and the self consumption In the Smart version it allows to optimize the self consumption by turning programmed loads with additional Plug and Switch accessories Elios4you Elios4you Smart a A x e lt i innovated by 4 noks im D Code label a C a k Current transformers pair READ AND KEEP THESE INSTRUCTIONS FOR REFERENCE Product identification this document refers to following devices ATTENTION Code ATTENTION Installation must be completed by E4U qualified personnel only The customer builder E4U S developer or installer accepts all liability and risk relating to the configuration of the product to achieve the expected results in relation to the C 2004 108 CE 2006 95 CE directive specific installation Any deficiencies in the ac 99 5 CEE knowledgment of the instructions may lead to The appliance or the product must malfunctions and or damage to the devices be disposed of separately in to which 4 NOKS cannot be held responsible m 4 2C
2. Elios4You proportionaltothe ff Wi Fi on green LED Butlan terminals 10 and 12 amount of energy E Button exchanged with the grid General alarm or WARNING Ensure that the positioning of the at p failed attempt to Generation amp Mains CTs are correct to the wiring of If ON energy currently red ee ee Fe the property Otherwise the resulting measurements being purchased from al aa vis smartdevice GREY YELLOW RED may not be reliable Ensure the Mains CT clamp Peak 3 Shows the OFF state off Shows the ON state on Shows the OFFLINE state is positioned after the Mains Meter but before the p Not used green for both the manual mode for both the manual mode meaning the plug switch is Consumer Unit Taking into account any Henley Blocks If ON energy currently green and or automatic mode and or automatic mode off from the mains or is out Split Junctions being sold to the grid of radio range WARNING Alterations to the length of CT cables may cause increases in marginal errors during measurements We do not recommend such alterations T EC H N CAL S pP ECS _______ TROUBLESHOOT General Characteristics nr 8 led of functionality diagnostic Parameter configuration with Tablet Problem Solutions Wi Fi 802 11b Access point AP Station STA B Output Power 15 1 dBm Radio Characteristics Red Cap only Elios4you Smart ZIGBEE Home Automation Profile HA1 2 a Change the Generatio
3. Main Meter z L a Main CT yellow label Fig 1 Main Meter MVS Main CT yellow label INSTALLATION SCHEMATIC PHOTOVOLTAIC PLANT INTO THE MAIN CIRCUIT BREAKER Green point and the direction l of the arrow K gt L towards l Main the main circuit breaker Circuit Breaker Alarm 2 NO Alarm 1 NO Relay normally open Hole for CONFIG button ID Code label 222222202 L i SIG Generation CT Red color SIG Main CT Black color mM TT Shield optional Generation CT 123456789XXXXX SIG Generation CT Black color Shield optional Main CT SIG Main CT Red color Green point and the direction of the arrow K L towards 8 Sr Main the main circuit breaker Circuit Breaker Alarm 2 NO Alarm 1 NO Relay normally open Hole for CONFIG button ID Codelabel s2seecectces eaeaeceueeaae SIG Generation CT Red color IG Main CT Black color mm Shield optional Generation CT Shield optional Main CT 123456789XXXXX SIG Generation CT Black color SIG Main CT Red color Generation meter Sty ES i Generation CT white label Generation meter Generation CT white label Innovated by 4 noks 4 noks SRL Via Per Sacile 158 Francenigo di Gaiarine TV Italy Tel 39 0434 768462 Fax 39 0438 694617 info 4 noks com www
4. at your smart device smartphone tablet is within radio range of the Wi Fi and or www 4 cloud org 5 Ensure the data values are correct ATTENTION Always seek advice from the Elios4you and associate your device i manufacturer or user manual of the appliance 9__ Install the Plug Switch to be paired to Elios4you with USER XXXXXXXX Press AN Home button to to go the Energy Performance page if it is suitable to control via radio plug or timer l 2 j A Check that G tion value dh h mi ietothatt meren 3 Make sure that the Plug Switch is not paired with a network already Red LED flashing otherwise a a a o a ATTENTION Be sure to configure the Smart perform the disassociation before continuing see manual for Smart Plug Switch ATTENTION If you are configuring the Elios4you APP Check that the energy Consumption 4 value relative to the real time consumption you Plug Switch correctly as per the instructions via the Router AP data will be visible via the 4 Cloud HAE voce a iron epeciie appliance maniac ier 4 Select Menu icon in the Ellos4you App App gt Red Cap gt Add Smart Plug Dashboard after approximately 1 hour from configuration ee 5 Carefully follow the Wizard in the Elios4you App ATTENTION Configuring Elios4you in Indirect Mode grants access through the broadband Router 6 Once complete go back to the Home Screen of the App oN select the Consumption icon Eag AP allowing all data to
5. be sent to the 4 Cloud visible remotely through the Elios4you APP when taking you to the Consumption Details page where you will see icons for the management of 4 Cloud is activated and also via the 4 Cloud Dashboard web portal Go to http www 4 cloud individual appliances ATTENTION org and follow the instructions to register your device Using the credentials on the label provided see left 7 To modify the settings of individual Plug Switch select the corresponding icon F i gt WARNING if the generation energy LED f does not NOTE repeat the above procedure for the installation of additional Smart Plug Switch blink when the PV installation is producing energy it Eli l eet los4you Front Panel Icons is necessary to invert the Generation CT orientation y ATTENTION Within 1 minute of the pairing procedure you will be able to see the Smart Plug Switch by swapping the connection of the wires of Elios4You ten He Elios A terminals 7 and 9 Blink frequency red f state In the Elios4you App proportional to the En WARNINGS 1 the EDS detect he wrong amount of generated ES DIFFERENT STATES OF THE SMART PLUG SWITCH IN THE APP energy How sold energy when It should report a energy of the pv plant Mi SMART SWITCH SMART PLUG situation of purchased energy or vice versa it is iom necessary to invert the mains CT yellow label by Blink frequency red a i a Power supply green Swapping the connection of the wires of
6. cordance with the local regulations The responsibility of 4 NOKS in relation to the regarding disposal Elios4you Elios4youSmart All models are compliant to directive devices manufactured is regulated by the gen eral terms amp conditions Be careful to ensure all works being carried out are completed by quali fied personnel during which no power is being supplied to the devices 4 NOKS hereby declares that these products conform to the essential requirements and to all relevant specifications established by Directive 1999 5 CE The declaration of conformity may be consulted on the website www 4 noks com INSTALLATION MANAGING APPLIANCES VIA ATTENTION 1 Secure the device on a DIN rail following the connections showed in the previous scheme Fig 1 ATTENTION ELICOS4YOUSMART OR RED CAP ACC ESSO RY and Fig 2 ATTENTION in order to protect against overvoltages 2 Once the device is installed and powered on download the free Elios4you APP on your own DO NOT CONNECT THE SMART PLUG fe Open Me EOS YOU mT and short circuits the device must be powered via smart device smartphone or tablet from Playstore Android or App Store iOS SWITCH TO 2 Press Menu Button gt Red Cap gt Activate Red Cap gt Confirm an easily accessible and externally located sectionin 7 j j j iva Ai ee 3 Open the App and start the Wizard Configuration follo
7. n CT clamp white label orientation by inverting the green dot or the arrow direction inside the clamp 2405 MHz 2480 MHz IEEE 802 15 4 compatible Nominal transmission Power 10dBm Internal PCB Antenna 1 can t see my PV system en to the opposite direction i ergy generation in the App s b Check that the Generation CT clamp white label is only clamped around the PV Live cable not including the Neutral cable Power Supply 230Vac 20 2 W Home Page c Check that the CT clamp core is not broken or cracked inside you may hear a buzzing noise Internal Memory Historical data up to two months with sampling every 15 minutes d Check that the Generation CT clamp white label is properly closed be sure not to apply excessive force 2 The energy generation visible Manne External alarm free contact connected to the inverter or auxiliary contact breakers Lack of production in absence of on the App is definitely less a Ensure that the Elios4you transmitter is powered from the same Live phase as the Mains CT clamp yellow label data after 4 hours in the central time zone from 10 00 to 14 00 than the value read from the b Check that the Generation CT clamp white label is properly closed be sure not to apply excessive force Connections Screw terminals for 230 V ac Screw terminals for CT Screw terminals for signal input alarm DL Dimensions of C T hole Internal diameter 16 mm a The Consumotion ine hasl Ensure tha
8. r any Henley Block Failing to do so will not give an accurate measure of total consumption 6 During the night the con gt RN alpine while or a Change the Mains CT clamp yellow label orientation by inverting the green dot or the arrow direction inside the clamp J ing tie Gay consumption Is to the opposite direction Di i always more than the ex PP i imensions mm pected value 7 The App shows a consump a Change the Mains CT clamp yellow label orientation by inverting the green dot or the arrow direction inside the clamp tion value much higher than to ne OP Poste aleet on oe b Ensure that the Mains CT clamp yellow label is clamped over the Mains Live phase cable after the Mains Meter and before mene the Consumer Unit and or any Henley Block Failing to do so will not give an accurate measure of total consumption
9. t the Mains CT clamp yellow label is clamped over the Mains Live phase cable after the Mains Meter and before 7 p the Consumer Unit and or any Henley Block Failing to do so will not give an accurate measure of total consumption Antenna Wi Fi external antenna SMA RP connector the same shape as the Gen i po i eration line in the graph Ensure that the Neutral cable is not included within the Generation Mains CT clamps Environment Parameters Operting temperature 0 50 C International Protection IP45 Check that the CT clamp cores are not broken or cracked inside you may hear a buzzing noise oan a Compliant with directives 2004 108 CE Directive EMC 2006 95 CE Low Voltage Directive 99 5 CEE Radio CE Declarations of Equipment Directive Standards and or technical specifications applied ETSI EN 300 328v1 8 1 2012 06 ETSI EN 4 It seems that the Consump Ensure that the Mains CT clamp yellow label is clamped over the Mains Live phase cable after the Mains Meter and before ae se ee the Consumer Unit and or any Henley Block Failing to do so will not give an accurate measure of total consumption CONTATE 301 489 17v2 2 1 2012 ETSI EN 301 489 1v1 9 2 2011 EN 61326 1 2013 EN 60950 1 2006 A11 2009 5 can never see Purchased a Ensure that the Mains CT clamp yellow label is clamped over the Mains Live phase cable after the Mains Meter and before m 60 rF 11 g Energy in my system the Consumer Unit and o
10. wing the steps visible on your smartphone medical equipment the involountary deactiva breaker thermal magnetic breaker or 230 Vac 1 A fuse tion can cause life threatenina situations TO tablet read the Elios4you APP Quick Guide for further information g onua SMART PLUG SWITCH PAIRING ATTENTION Before installing Elios4you remove devices INAL CAN CAUSE Galaga NUY OLUE IN l l 4 Set correct parameters for your PV system and your energy provider using the App menu f idental activation eg i the label with device credentials and attach below case of accidental activation eg irons i 7 eT ni or keep in a safe place for future reference and or L Press Menu button appliances that can be damaged by turning on ATTENTION When pairing devices for the first time keep devices within close range to the Elios4you monitoring via the 4 Cloud Dashboard web portal off frequently transmitter The devices can then be moved around to required position after pairing is complete www 4 cloud org Select FAA Parameter Settings appliances that cannot be interrupted The Smart Plug Switch does not need to be close to the Wi Fi router as the Smart Plug Switch APERE n Select Energy Management and set values appliances that require a continuous current communicates using ZigBee RF directly to the Elios4you transmitter and not through Wi Fi _ supply Register on Press OK when finished to save new values DE o Verify th