Home

DJ 1T/DJ 2T User Manual DJ 1T DJ 2T

image

Contents

1. 9 ee 10 6 1 DIP Switches Settings of Doorstation 10 6 2 DIP Switches Settings of Monitor 10 NOUO MER EN ee eee de nee nee ee 12 7 Cables Requirements 13 Camera Lens Night View LED Speaker 176 mm Nameplate Microphone Rainy Cover 90 mm 23 mm Note DJ 2T has two call buttons 1 2 3 a Lock Control Jumper DEN Doorstation Code DIP O ms MIC adjustment SPK adjustment Main Connect Port Lock Control Jumper To select the lock type see 5 2 1 5 2 2 Doorstation Code DIP Total 4 doorstations can be supported see 6 1 e Main Connect Port To connect the bus line and the electronic locks BUS Connect to the bus line no polarity External lock power input connect to the power positive power 51 52 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected Lock Power supply 12Vdc 300mA Internal Power Power Consumtion 1W in standby 12W in working NO COM dry contact Max 48V dc 1 5A
2. DJ 1T DJ 2T User Manual CONTENTS and PUNCIONS LIU ee MNT 1 2 Terminal Descriptions nnns 1 ee ee 2 2 4 1 Mounting Without Rainy 2 4 2 Mounting With Rainy 3 4 3 Placing Name Label aaa 3 4 4 Adjusting Camera Angle eee 4 5 System Wiring and Connections 4 9 1 Basie CONNGCHON ca en 4 5 2 Electric Lock Connection 5 5 2 1 Door Lock Controlled with Internal Power 5 5 2 2 Door Lock Controlled with Dry Contact 5 5 2 3 How to setup the unlock parameter time and unlocking in Monitor 6 5 3 Multi Doorstations Connection 7 5 4 Multi Monitors Connection 8 5 4 1 Basic IN OUT Wiring Mode 8 5 4 2 With VD 04 Wiring Mode
3. Unlocking time 1 to 9 seconds set by Monitor Working temperature 10 C 45 C 4 1 Mounting Without Rainy Cover 165cm 4 2 Mounting With Rainy Cover 4 3 Placing Name Label Move the plastic cover away to open the transparent name label cover insert a name paper then put the plastic cover back to the panel name label SS 4 4 Adjusting Camera Angle use a screwdriver to loosen the screw and then adjust the angle of the camera then fix the screw 5 1 Basic Connection 5 2 Electric Lock Connection 5 2 1 Door Lock Controlled with Internal Power Note 1 2 9 4 connect lock Electronic lock of Power on to unlock type should be used The door lock is limited to 12V and holding current must be less than 250mA The door lock control is not timed from Exit Button EB The Unlock Mode Parameter of Monitor must be set to 0 by default connect two locks 1 2 3 4 2 Jumper position in 1 2 Jumper position in 1 2 5 2 2 Door Lock Controlled with Dry Contact Note 1 pe m The external power supply must be used according to the lock The inside relay contact is restricted to AC or DC 24V 3A The jumper must be taken off before connecting Setup the
4. button B set the user code to 16 AT 6 3 Notices Power supply 85 260Vac input 24Vdc gt 3A output Connect with multi doorstations or multi monitors up to 2 or above Power supply 85 260Vac input 24Vdc 1A output for C onnect with one doorstation and on basic kit only 4 DIN modules e monitor VM 35 can be connected two x5 The maximum distance of the wiring is limited in the easydoor system Using different cables may also effect the maximum distance the system can reach When Monitor quantity lt 20 Twisted cable 2x0 75 60 60 30 The farest monitor Twisted cable 2x1 mm 80 80 40 When Monitor quantity gt 20 Twisted cable 2x1 mm 70 30 20 Twisted cable 2x1 5 mm 70 50 30 13 4
5. Information itemand and hold for 2s press MENU button to enter next page 1 must connect DJ 1 2 completely before setting 2 the parameter will be saved in doorstation automatically so you need only set on one monitor a 5 3 Multi Doorstations Connection monitors Bae 680848884 m m H aanmaaoaaugansaonmnu 1 1 a n s p p na M K T i PRR 22 2 2 22222 4 Camera 3 Camera 2 Camera 1 Camera L2 PL Si S2 5 jen em 5 4 Multi Monitors Connection 5 4 1 Basic IN OUT Wiring Mode ON ID HE monitor 23456 Code 31 DIP 6 on cl ON mn 1 monitor Code 14 DIP 6 off 1 I I ON 1 monitor Code 32 DIP 6 off 9 4 2 With VD 04 Wiring Mode ON AARDAL 123456 monitor Code 15 DIP 6 on Code 13 DIP 6 on uut monitor 3456 1 Code 3 DIP B 0n escasa m Code 1 DIP G on a aaa 5 mm lu 123450 monitor Code 14 DIP 6 on Code 12 DIP 6 on els 180008 1 2345 6 monitor Code 2 DIP 6 on ON D Nt 123456 monitor Code 32 DIP 6 o
6. Unlock Mode of Monitor for different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 connect one lock 1 2 3 Take off the Jumper o BUS PL Sf S2 S eooooo Power supply 1 Press MENU button two times to enter the MAIN MENU page then press setup item 1 0 Unlock Time Unlock Mode Exit 6 Use A V to select the item use lt q P gt to change the value of the item select Exit item press MENU button to save the settings automatically Note connect two locks 1 2 3 Take off the Jumper BUS PL 51 52 S i Outdoor Tone 01 i 05 i Monitor Time 1min f Intercom Tone Password q Advanced Set Meg Exit 5 3 The default password is press A button to increase decrease the value Press button to select the location after finishing press MENU button to enter next step 2 Select Advanced Set item and press MENU button to enter a password will be asked _ j Hardware ver 0302 Slave AddrSet 0 Software ver 0168 Guard UntSet 0 Voltage 22 4V i Date Time Set Manufacture 000 Other Settings Restore to default Information Exit 5 55 UNLOCK button 4 Select
7. n TT cestocomesos us 7r02r23nn c0 n o 1 po i 85 260AC 1 m 6 1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured The switches can be modified etther before or after installation Ej Default setting ID 0 00 set to the first Door Station ID 2 01 set to the third Door Station ID 3 11 set to the fourth Door Station ID 1 10 set to the second Door Station 6 2 DIP Switches Settings of Monitor There are 6 bit switches in total The DIP switches are used to configure the User Code for each Monitor Bit 6 is line terminal switch which have to be set to ON if the Monitor is in the end of the line bus otherwise set to OFF The monitor is at the end of not at the end tha bus of the bus 1 2345 10 N o 2 gt lt lt H D o O gt um o m 4 m an Q O K N gt lt S Ee T o uw k gt 2 z 0 m 2 2 m EN r3 I m m Note Monitors response button A must set the user code to 32 and

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones  JVC TK-C1460 Security Camera User Manual  SYNTHESE A.S 15-07-10  MANUAL DE INSTRUÇÕES - Bilfinger Mauell Serviçios e  CFD-RG880CP  Gigaset Repeater  MANUAL DE INSTRUÇÕES PARA INSTALAÇÃO  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.