Home
Product Specification - Meriton East (HK) Ltd.
Contents
1. Cool air slides off to reach the corner of the room From a corner to the centre Covers even a spacious room 40 5 C ba Cooling 60 min Off timer turns on Off timer stops air conditioner Cooling operation Room temperature is raised by 0 5 C after 60 minutes Anticorrosion Treatment of Outdoor Heat Exchanger Fins N The outdoor units heat exchanger fins are processed using a special anticorrosion treatment The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion A hydrophilic film layer also prevents rust caused by the run off of water droplets Additional durability is provided by a rustproof steel sheet on the bottom of the unit Self Diagonosis with Digital Display 17 Malfunction codes are shown on the digital SELF display panel of the wireless remote controller for fast and easy maintenance Wireless remote controller for FTN50 60J New Powerful Operation Selects fan speed i Selects mode eae IS cooling dry fan only operation Cancels On Off Timer 24 Hour On Timer 24 Hour Off Timer DKE and Night Set Mode EON Cross section of anticorrosion treated fin Hydrophilic film Aluminium Corrosion resistant o P 1 acrylic resin Heat exchanger fin C n Sets room temperature f a OONOF wwe C On Off switch Vertical ang S up and down Horizontal Auto Swing mx cz
2. Warning Daikin Industries Ltd s products are manufactured for export to numerous countries throughout the PCRH K1 01 D world Daikin Industries Ltd does not have control over which products are exported to and used in a dA particular country Prior to purchase please therefore confirm with your local authorised importer distributor and or retailer whether this product conforms to the applicable standards and is suitable for use in the region where the product will be used This statement does not purport to exclude restrict or modify the application of any local legislation Ask a qualified installer or contractor to install this product Do not try to install the product yourself Improper installation can result in water or refrigerant leakage electrical shock fire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion Read the Users Manual carefully before using this product The User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor and or retailer Split Type Air Conditioners Eoo R
3. are appropriate for spacious rooms as living rooms FTN50JV1 RN50JV1 5 3 kW 18 090 Btu h gt FTN60JV1 RNGOJV1 SN EeEesepemee TT 6 7 kW 22 860 Btu h FTN50 60J Vertical Auto Swing up and down Function List Horizontal Auto Swing left and right ncoor al 3 D Airflow omfortable Airflow POWER Power Airflow Dual Flaps Vertical Auto Swing Zl ke automatically moves the flaps Wide Angle Louvers up and down and Horizontal Auto Swing automatically moves the louvres to Z Vertical Auto Swing up and down the left and right 3 D Airflow combines Vertical and Horizontal Auto Swing to circulate air to EN S z L1 o7 Horizontal Auto Swing left and right every part of a room for uniform cooling of even large spaces These functions can create oy 3 D Airflow comfortable airflow Comfort Control Programme Dry Function 32 e Auto Fan Speed Lifestyle Convenience New Powerful Operation Indoor Unit On Off Switch mel ee Cleanliness Air Purifying Filter with Photocatalytic Deodorising Function Wipe Clean Flat Panel 24 Hour On Off Timer OR S Night Set Mode Worry Free Auto Restart after Power Failure SELF Self Diagnosis with Digital Display l LE Outdoor unit Worry Free Anticorrosion Treatment of Outdoor Heat Exchanger Fins EX Main Features Energy Savings and Clean Air wi
4. easy maintenance gt See page 8 Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anticorrosion treatment The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion gt See page 8 Specifications and Options Specifications aoaeiiaane Indoor unit FTN50JV1 FTN60JV1 Outdoor unit RN50JV1 RN60JV1 kW 5 3 6 7 MaRan Btu h 18 090 22 860 Power supply 1 phase 220 240 V 50Hz Running current A 7 5 10 2 Power consumption W 1 640 2 210 COP W W 3 23 3 03 Indoor unit FTN50JV1 FTN60JV1 Front panel colour White Airflow rate H m3 min cfm 17 5 618 18 5 653 Fan speed 5 steps and automatic Sound levels H L dB A 45 35 47 36 Dimensions H x W x D mm 290 x 1 050 x 238 Machine weight kg 12 Outdoor unit RN50OJV1 RN60JV1 Casing colour Ivory white Type Hermetically sealed rotary type Compresor Motor output W 1 300 1 700 Refrigerant charge R 410A kg 1 6 2 0 Sound levels dB A 50 52 Dimensions H x W x D mm 735 x 825 x 300 770 x 900 x 320 Machine weight kg 48 63 Operation range CDB 19 4 to 46 Liquid 26 4 Piping connections Gas mm 12 7 15 9 Drain 18 0 Max piping length 30 Max height difference m 20 Note The above values are based on operation with a 220V 50Hz power supply Measurement conditions 1 Cooling capacity is b
5. FTN50 60J Air Purifying Filter with Photocatalytic Deodorising Function Traps microscopic particles decomposes odours and even removes bacteria and viruses Photocatalytic Mechanism DN Ye Light strikes the photocatalyst and activates Active the surface particles particles A chemical reaction decomposes the odours into CO2 Os and H2 The odourless substances are released into the air Other Features Airflow and Reliable Functions Power Airflow Dual Flaps zzz Power Airflow Dual Flaps can flatten out POWER during cooling operation to deliver cool air to the corners of a room Wide Angle Louvers The smoothly curved Wide Angle Louvers provide wide airflow coverage for effective cooling operation no matter where the indoor unit is placed in a room The louvers can be adjusted by hand New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20 minute period After this the unit automatically returns to its previous settings This function is activated by pushing the POWERFUL button on the remote controller So for example now when you come home on a hot day a powerful airflow will always be right at your fingertips Night Set Mode lt Pressing the Off timer button automatically lt J selects Night Set Mode This function prevents excessive cooling for your pleasant sleep Room temperature is raised by 0 5 C after 60 minutes for cooling operation
6. ONA ESA rA R 410A Special Warning The refrigerant has been changed from R 22 to R 410A Please read the Installation Manual carefully before installing this product Cautions on product corrosion 1 Air conditioners should not be installed in areas where corrosive gases such as acid gas or alkaline gas are produced 2 If the outdoor unit is to be installed close to the sea shore direct exposure to the sea breeze should be avoided If you need to install the outdoor unit close to the sea shore contact your local distributor Organization diganian DAIKIN INDUSTRIES LTD l ANIZAT DAIKIN INDUSTRIES i NNN NMP Tree sE R Onn THAILAND LTD ISO s Allof the Daikin Group s business Scope of Registration S 1400 facilities and subsidiaries in Japan s Scope of Registration i THE DESIGN DEVELOPMENT AND MANUFACTURE OF a are certified under the ISO 14001 THE DESIGN DEVELOPMENT LS Jac ain international standard for COMMERCIAL AIR CONDITIONING HEATING COOLING REFRIGERATING EQUIPMENT COMMERCIAL HEATING AND MANUFACTURE OF AIR o environment management Sek es EQUIPMENT RESIDENTIAL AIR CONDITIONING KfecTeley CONDITIONERS AND THE Mearyn nus EQUIPMENT HEAT RECLAIM VENTILATION AIR COMPONENTS INCLUDING EC99J2044 JMI 0107 CLEANING EQUIPMENT MARINE TYPE CONTAINER JQA 1452 COMPRESSORS USED FOR THEM REFRIGERATION UNITS COMPRESSORS AND VALVES BND DAIKIN INDUSTRIES LTD Head Office Umeda Cent
7. a left and righ Sets clock Sets timer Function Dictionary Comfortable Airflow ryz7 Power Airflow Dual Flaps CUAL Power Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room gt See page 7 Wide Angle Louvres The smoothly curved Wide Angle Louvres provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room gt See page 7 E3 BY Vertical Auto Swing up and down This function automatically moves the flaps up and down to distribute air across a room gt See page 4 A R Horizontal Auto Swing left and right Horizontal Auto Swing automatically moves the louvres to the left and right to cover a room with cool air gt See page 4 7 _ 3 D Airflow This function combines Vertical and Horizontal Auto Swing to circulate a cloud of cool air right to the corners of even large spaces gt See page 4 A Lifestyle Convenience New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20 minute period After this the unit automatically returns to its previous settings gt See page 7 Indoor Unit On Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged Cleanliness s Air Purifying Filter with Photocatalytic e De
8. ased on indoor temp 27 CDB 19 CWB outdoor temp 35 CDB piping length 7 5 m 2 Sound levels are based on temperature condition in 1 above These are anechoic conversion values These values are normally somewhat higher during actual opration as a result of ambient conditions Options indoor No Item FTN50 60JV1 1 Air purifying filter with photocatalytic deodorising function without frame KAF952A42 2 Remote controller loss prevention with chain KKF917A4 Notes 1 The filter is a standard accessory It should be replaced after approximately every 3 years iss ep Remote controller loss prevention with chain Air purifying filter with photocatalytic deodorising function without frame KAF952A42 KKF917A4 No Item RN50 60JV1 1 Air direction adjustment grille KPW945A4 2 Drain plug KKP937A4 Specifications are subject to change
9. er Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan Tokyo Office JR Shinagawa East Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan http www daikin com global_ac All rights reserved Printed in Japan 06 10 005 Y K P C Specifications designs and other content appearing in this brochure are current as of June 2010 but subject to change without notice par j a pA pA pA pA p a a a gt og Always around Us They are always there just like air We believe air conditioners should have simple designs that merge smoothly with our daily lives Daikin s subtle flat panel design blends seamlessly into any room interior Uniform models of 5 0 and 6 0 kW using R 410A HFC are available now Energy Saving The 5 0 kW model delivers a high COP of 3 23 A high COP is important for energy efficiency gt See page 5 Comfortable Airflow Vertical and Horizontal Auto Swing plus other airflow functions give you more comfortable airflow gt See page 4 and 7 Clear Air with Less Dust and Odours Air Purifying Filter with Photocatalytic Deodorising function traps dust decompose odours and even removes bacteria and viruses oa gt See page 6 Split Type FTN series A Refreshingly Simple Design The stylish flat panel design creates a simplicity and sophistication that enhances any interior space FTN series offer 5 0 and 6 0 kW models that
10. odorising Function This filter traps microscopic particles decomposes odours and even removes bacteria and viruses It can be used for up to 3 years gt See page 6 Wipe Clean Flat Panel Ea The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface The flat panel can also be easily removed for more thorough cleaning gt See page 5 Comfort Control Programme Dry Function S This function automatically reduces the level of humidity Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature Timers 24 Hour On Off Timer ie This timer can be preset to start and stop at any time within a 24 hour period The air conditioner is started stopped simply by pressing the On Off setting timer button on the wireless remote controller Night Set Mode lt 4 Pressing the Off timer button automatically selects Night Set Mode Room temperature is raised by 0 5 C after 60 minutes to prevent excessive cooling for your pleasant sleep gt See page 7 Worry Free Auto Restart After Power Failure C The air conditioner memorises the settings for mode airflow temperature etc and automatically returns to them when power is restored after a power failure lt 1 Self Diagnosis with Digital Display SELF Malfunction codes are shown on the digital display panel LLD of the wireless remote controller for fast and
11. rilles unless these grilles increased suction are cleaned regularly resistance Dust and Odours Air Purifying Filter with Photocatalytic Deodorising Function 4 Air Purifying Filter with Photocatalytic Deodorising Function is able to trap microscopic particles decompose odours and even remove bacteria and deactivate viruses This filter features a large active surface area that effectively cleans the high volumes of air required to air condition living rooms The filter delivers consistent performance for approximately 3 years if washing with water is performed once in 6 months Air Purifying Filter with Photocatalytic Deodorising Function oO KAF952A42 This filter is not a medical devices Benefits such as the adsorption and decomposition of bacteria and viruses are only effective for substances that are collected on and in direct contact with the Air Purifying Filter with Photocatalytic Deodorising Function Bacteria removal test Testing method Dropping method Testing organisation Japan Spinners Inspecting Foundation Result certificate No 012553 1 and 012553 2 Photocatalytic deodorising mechanism Photocatalytic deodorising filters are made of titanium oxide When titanium oxide is exposed to light a powerful oxidising action occurs This decomposes substances adsorbed on the filter surface into odourless carbon dioxide and water Air filter atches dust Ms a c m i
12. th Less High Energy Savings FTN50J provides a high COP of 3 23 5 0 and 6 0 kW models are appropriate for spacious rooms as living rooms What is COP An air conditioner s COP Coefficient of Performance indicates how efficiently the unit uses energy A higher COP means greater energy efficiency It also means lower electricity consumption so you save money Capacity W COP W W Power consumption W Quiet Sound Levels The FIN series offers low sound levels Sound levels for 5 0 kW model are 35 dB A for indoor unit operation and 50 dB A for outdoor unit operation dB A Indoor unit FTN50J FTN60J Sound levels L 35 36 Outdoor unit RN50J RN60J Sound levels 50 52 Wipe Clean Flat Panel Flat panel models can be cleaned Ea instantly with a single wipe of a cloth across their smooth surface If more thorough cleaning is required the panel can also be easily removed from the unit FTN50J FTN60J COP ww 3 23 3 03 Indoor unit Outdoor unit of Normal office JRID Rustling of leaves Llibrary Pendulum of a wall clock Based on Examples of Sound Levels Ministry of the Environment Japan November 12 2002 Conventional Front Grille Design 1 Difficult to remove dust on the grille through wiping rss alone r Fs Dust 2 Reduced capacity due to increased suction resistance Front grille design units collect dust on their air inlet 3 High sound levels due to g
Download Pdf Manuals
Related Search
Related Contents
Numéro spécial TRACTEUR AGRICOLE Tech air TSC156V1 Copyright © All rights reserved.
Failed to retrieve file