Home
Quick Start Installation Guide
Contents
1. into the unit Test the battery backup system by unplugging the A C power adapter from the unit All phone numbers programmed into the unit will receive the text notification Congratulations Your installation is complete you can now enjoy peace of mind knowing your basement is protected Copyright 2012 OmniSite All Rights Reserved OmniSite PitBoss Product Division 494 S Emerson Avenue Suite E Greenwood IN 46143 USA Need more guidance For 24 hour tech support call 1 888 454 5051 The following items are available to you at www pumpalarm com In depth Users Manual Installation video How it works video Online store where you can buy units accessories and renew your wireless service Live chat Monday Friday 8 00 am to 5 00 pm EST Support ticket system Partner program Standard Warranty This warranty is good for two 2 years from the purchase date and covers all manufacturing defects If the product is damaged for whatever reason OmniSite must first issue a Returned Material Authorization RMA number This number can be obtained by calling OmniSite and a copy will be provided by email A copy of the RMA must be included with any materials shipped to OmniSite For a unit to be reviewed the entire assembly must be sent back unless specifically listed otherwise on the RMA form to OmniSite The product or component parts will be inspected within 1 3 days from arrival at our f
2. F MARKET VALUE LOSS OF RENTAL VALUE OR FOR ANY LOSS OF PROFITS OR OTHER SPECIAL INCIDENTAL RESULTING CONSEQUENTIAL OR EXEMPLARY DAMAGE Copyright 2012 OmniSite All Rights Reserved Copyright 2012 OmniSite All Rights Reserved Protected by US Patent 7 228 129 7 778 633 8 060 078 and others pending
3. ONE SCREEN 8 7 Copyright 2012 OmniSite All Rights Reserved Name the PitBoss again by texting the unit using the following format Name space John Doe Residence If successful the unit will chirp twice and you will receive a text message with the current settings See online manual if this step is not successful Naming the unit EXAMPLE CELL PHONE SCREEN Name John Doe Residence Unit settings PitBoss Settings Name John Doe Residence 1 5557654321 2 3 Contractor Contact EXAMPLE CELL PHONE SCREEN 10 9 Copyright 2012 OmniSite All Rights Reserved Optional Contractor Setup Your PitBoss allows you to configure a contractor name with associated contact information When this information is configured the PitBoss appends this contact information to the end of alarm notifications input alarms low battery power loss etc so you know who to call in an emergency To configure the contractor name text the unit using the following format Contractor space Mike s Plumbing If successful the unit will chirp twice and you will receive a text message with the current settings See online manual if this step is not successful Contractor Contractor Mike s Plumbing EXAMPLE CELL PHONE SCREEN 12 11 Contractor settings PitBoss Settings Name John Doe Residence 1 5557654321 2 3 Contractor Mike s Plumbing Contact EXAMPLE CELL PHONE SCREEN Copyright 2012 OmniSite All
4. Quick Start Installation Guide V 2 0 Copyright 2012 OmniSite All Rights Reserved Or visit www pumpalarm com installation Please scan the image below with your smartphone to view our Installation Guide Copyright 2012 OmniSite All Rights Reserved Components 1 PitBoss Cellular Pump Alarm 2 A C Power Adapter 3 Pit Sensor 1 6 4 Pit Sensor 2 15 5 8 Mounting Straps 6 ea Copyright 2012 OmniSite All Rights Reserved If any component parts are missing or damaged immediately call OmniSite at 1 888 454 5051 M F 8 00 am to 5 00 pm EST Do not return product to retail store 1 2 3 4 5 Getting to know your PitBoss 1 Status Light Indicates the status of the PitBoss Refer to the online manual at www pumpalarm com for a description of the blink patterns 2 Low Battery Light Indicates the backup batteries are low when the light is flashing Replace with 4 AAA Alkaline Energizer batteries 3 Push to Test Hold to Configure Press and hold this button for 3 seconds to put the unit into configuration mode for setup Momentarily press and release this button to send a test notification to all phone numbers configured in the unit 4 Pit Sensor 1 Status Light This light blinks when the pit sensor detects water 5 Pit Sensor 2 Status Light This light blinks when the pit sensor detects water 6 Power Jack Power plug from A C power adapter plugs in here 7 On Off Swi
5. Rights Reserved Optional Contractor Setup To configure the contractor s contact phone number text the unit using the following format Contact space 888 454 5051 If successful the unit will chirp twice and you will receive a text message with the current settings See online manual if this step is not successful Contractor settings PitBoss Settings Name John Doe Residence 1 5557654321 2 3 Contractor Mike s Plumbing Contact 8884545051 EXAMPLE CELL PHONE SCREEN 14 13 Contractor contact phone number EXAMPLE CELL PHONE SCREEN Contact 8884545051 Copyright 2012 OmniSite All Rights Reserved Installation and configuration is now complete Press and hold the Push to Test Hold to Configure button for 3 seconds Unit will chirp twice and status light will go to solid green This will take your unit out of configuration mode Test notifcation John Doe Residence is operating correctly at 8 55AM on 07 18 2012 EXAMPLE CELL PHONE SCREEN 15 Test your PitBoss by pressing and releasing the Push to Test button The unit will chirp one time and send a text notification to all numbers that have been added See online manual if this step is not successful 16 Copyright 2012 OmniSite All Rights Reserved Important Test your Pit Sensors by submerging them into a cup of water This will trigger the unit to sound an audible alarm and send a text notification to all phone numbers programmed
6. acility If the damage or defect is found to be the fault of OmniSite and the device is still under warranty the device will be repaired at no charge and shipped as quickly as possible However any damages found to be the fault of the Purchaser or any damages not covered under this warranty will not be repaired until payment is received Any claim under this warranty must be presented during the warranty period and within 30 days after any covered condition has occurred Upon receipt the Purchaser should inspect the package contents immediately and file any delivery damage claims with the delivering carrier OmniSite recommends saving the original box and packing material The Purchaser is responsible for any damage to a product or component parts if returned improperly packaged The warranty period shall not be extended by the replacement of materials under this warranty but the remaining warranty period shall continue in effect and be applicable to the replaced or repaired products or component parts areas under conditions of the warranty Upon expiration of the warranty period all liability of OmniSite shall be terminated This warranty does not cover damage due to acts of God fire flood lightning etc nor product misuse and accidental damage OmniSite shall not be liable for any injury loss or damage direct or consequential arising out of the use or the ability to use the product This warranty gives specific legal rights You may have ot
7. her rights which vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages so that the above limitation of exclusion may not apply to you Payment of the Wireless Service Charge covers ONLY cellular transmission fees and in no way extends any portion of this warranty This fee does not include out of warranty service or repair WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation OmniSite makes no representation or warranty as to suitability or fitness of these devices for any specific application THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THOSE CONCERNING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS LIMITED WARRANTY IS ALSO IN LIEU OF ANY OTHER POSSIBLE LIABILITIES OF THE SELLER OR MANUFACTURER WHETHER ALLEGED TO ARISE BY AGREEMENT OR BY OPERATION OF LAW RESPECTING THE SALE APPLICATION USE OR FUNCTION OF PRODUCTS INCLUDING BUT NOT LIMITED TO CLAIMS OF NEGLIGENCE GROSS NEGLIGENCE STRICT LIABILITY OR ANY OTHER TORT IN NO EVENT SHALL THE SELLER OR MANUFACTURER BE LIABLE FOR PERSONAL INJURY OR PROPERTY DAMAGE REAL OR PERSONAL ATTRIBUTED TO ITS PRODUCTS NOR FOR ANY EXCAVATION REMOVAL REAPPLICATION DOWNTIME CLEANUP LOSS OF USE LOSS OF OPPORTUNITY LOSS O
8. tch Turns PitBoss on and off 8 QR Code Scan this with your smartphone to download a copy of the complete user manual 9 Pit Sensor Inputs Jacks Insert one of the included Pit Sensor connectors here To remove the connector squeeze tab and pull Copyright 2012 OmniSite All Rights Reserved 1 2 3 4 5 6 7 8 9 Copyright 2012 OmniSite All Rights Reserved Remove 4 screws lift lid and install 4 AAA Alkaline Energizer batteries Observe battery Polarity Negative end of the battery touches the spring in each Holder Save the PitBoss phone number found inside the lid as a contact in your cell phone You ll need this number later to configure the PitBoss Reinstall the lid and tighten screws EXAMPLE CELL PHONE SCREEN Phone 555 123 4567 Phone 555 123 4567 555 123 4567 Unit 12345 For technical support 1 888 454 5051 www pumpalarm com add photo PitBoss Last Mobile iPhone Company 2 1 Copyright 2012 OmniSite All Rights Reserved Connect one of the Pit Sensors into one of the Pit Sensor Input Jacks at the bottom of the unit and secure the sensor in the sump pit at the height you want an alarm to be sent using 1 of the straps included Loop the sensor wire around the strap to prevent the sensor from slipping down the pipe Don t mount the sensor below inflow pipe where it could be splashed Repeat for Pit 2 if present Mount the PitBoss unit to the s
9. ump pump discharge pipe about 4 ft above well cover using two of the mounting straps included Unit can also be wall mounted 4 3 Copyright 2012 OmniSite All Rights Reserved Plug A C adapter into a 120 VAC power outlet and then connect the power plug into the jack on the PitBoss Turn the On Off switch to On Once the status light turns solid green press and hold the Push to Test Hold to Configure button for 3 seconds Unit will chirp twice and status light will blink red amp green This will get the unit ready to receive text messages from your cell phone In the next step you will configure the unit by sending it text message commands 6 5 Copyright 2012 OmniSite All Rights Reserved Create and send a text message to the PitBoss phone number that you saved in step 2 using the following format Phone1 space lt 10 digit phone number gt This number will be saved to position 1 If successful the unit will chirp twice and you will receive a text message to the phone number you just entered If you want notifications to additional phones you can repeat this process up to two additional phones using the Phone 2 and Phone 3 commands See online manual if this step is not successful Phone1 space lt 10 digit phone number gt Adding phone numbers Phone1 5557654321 EXAMPLE CELL PHONE SCREEN Unit settings PitBoss Settings Name Your PitBoss 1 5557654321 2 3 Contractor Contact EXAMPLE CELL PH
Download Pdf Manuals
Related Search
Related Contents
Hoja técnica aditivos para asfalto GC - tui USER MANUAL Product Specification BQ403E MANUAL DE USUARIO BB504GPSAAC - bit 4,8 kVA AC Converters 6,0 kVA AC Converters User Manual LTM6002 ma # 0601-10 BDA Elektrokettenzug Typ 66/04 AK MANUEL D`UTILISATION トフンスミッタ Descargar ficha técnica Copyright © All rights reserved.