Home
Quanser Flexible Link Workbook
Contents
1. 2 1 5 Free Oscillation of a Second Order System The free oscillatory equation of motion of a second order system described by J x B x Kx 0 2 20 is shown in Figure 2 3 Assuming the initial conditions x 0 x0 and x 0 0 the Laplace transform of Equation 2 20 is X s x0 J s2 B J s K J 2 21 Figure 2 3 Free Oscillation Response The prototype second order equation is defined s2 2 ns 2 n 2 22 where is the damping ratio and n is the natural frequency Equating the characteristic equation in 2 21 to this gives 2 n K J 2 23 and 2 n B J 2 24 Based on the measured damping ratio and natural frequency the friction or stiffness of the system is K J 2 n 2 25 and the viscous damping is B 2 nJ 2 26 Finding the Natural Frequency The period of the oscillations in a system response can be found using the equation Tosc tn 1 t1 n 2 27 FLEXGAGE Workbook Student Version 8 where tn is the time of the nth oscillation t1 is the time of the first peak and n is the number of oscillations considered From this the damped natural frequency in radians per second is d 2 Tosc 2 28 and the undamped natural frequency is n d 1 2 2 29 Finding the Damping Ratio The damping ratio of a second order system can be found from its response For a typical second order under d
2. actual system behaves 2 Designing a controller with the Linear Quadratic Regular LQR technique is an iterative process In software you have to tune the Q and R matrices generate the gain K using LQR and either simulate the system or implement the control to see if you have the desired response The relationship between changing Q and R and the closed loop response is not evident However we can have a better idea on how changing the different elements in Q and R will effect the response We will only be changing the diagonal elements in Q thus let Q q1 0 0 0 0 q2 0 0 0 0 q3 0 0 0 0 q4 3 7 Since we are dealing with a single input system R is a scalar value Using the Q and R defined expand the cost function given in Equation 3 4 3 For the feedback control u Kx the Linear Quadratic Regular algorithm finds a gain K that minimizes the cost function J Matrix Q sets the weight on the states and determines how u will minimize J and hence how it generates gain K From your solution in Question 2 explain how increasing the diagonal elements qi effects the generated gain K k1 k2 k3 k4 4 Explain the effect of increasing R has on the generated gain K FLEXGAGE Workbook Student Version 18 3 4 Lab Experiments The control gain is designed using LQR through simulation first Once a gain that satisfies the requirements is found it is implemented on the actua
3. and the amplifier limits VMAX AMP and IMAX AMP config flexgage m Returns the Flexible Link model inertial Jl viscous damp ing Bl and sensor calibration constant K GAGE d model param m Calculates the SRV02 model parameters K and tau based on the device specifications Rm kt km Kg eta g Beq Jeq and eta m FLEXGAGE ABCD eqns student m Contains the incomplete state space A B C and D matri ces These are used to represent the Flexible Link system calc conversion constants m Returns various conversions factors s flexgage mdl Simulink file that simulates the Flexible Link system when using a full or partial state feedback control q flexgage id mdl When ran with QUARC this Simulink model measures the Flexible Link angle The measured response can then be used to find the stiffness of the link q flexgage val mdl This Simulink model is used with QUARC to compare the Flexible Link state space model with the measured re sponse from the actual system q flexgage mdl Simulink file that implements a closed loop state feedback controller on the actual FLEXGAGE system using QUARC Table 3 Files supplied with the SRV02 Flexible Link Control Laboratory 4 2 Setup for Finding Stiffness Before beginning in lab procedure outlined in Section 2 3 1 the q flexgage id Simulink diagram must be properly configured Follow these steps 1 Setup the SRV02 with the Flexible Link module as detailed in the Fle
4. etc Each of the required sections is completed Procedure Results Analysis and Conclusions Typed All grammar spelling correct Report layout is neat Does not exceed specified maximum page limit if any Pages are numbered Equations are consecutively numbered Figures are numbered axes have labels each figure has a descriptive caption Tables are numbered they include labels each table has a descriptive caption Data are presented in a useful format graphs numerical table charts diagrams No hand drawn sketches diagrams References are cited using correct format FLEXGAGE Workbook Student Version 30 REFERENCES 1 Quanser Inc QUARC User Manual 2 Quanser Inc SRV02 QUARC Integration 2008 3 Quanser Inc QUARC Installation Guide 2009 4 Quanser Inc SRV02 User Manual 2009 5 Quanser Inc QUARC Compatibility Table 2010 6 Quanser Inc SRV02 Rotary Flexible Link User Manual 2011 7 Norman S Nise Control Systems Engineering John Wiley amp Sons Inc 2008 FLEXGAGE Workbook Student Version v 1 0
5. matrix T B AB A2B AnB 3 2 equals the number of states in the system rank T n 3 3 FLEXGAGE Workbook Student Version 16 3 2 3 Linear Quadratic Regular LQR If A B are controllable then the Linear Quadratic Regular optimization method can be used to find a feedback control gain Given the plant model in Equation 2 14 find a control input u that minimizes the cost function J 0 x t Qx t u t Ru t dt 3 4 where Q and R are the weighting matrices The weighting matrices affect how LQR minimizes the function and are essentially tuning variables Given the control law u Kx the state space in Equation 2 14 becomes x Ax B Kx A BK x 3 2 4 Feedback Control The feedback control loop that in Figure 3 1 is designed to stabilize the servo to a desired position d while mini mizing the deflection of the flexible link The reference state is defined xd d 0 0 0 3 5 and the controller is u K xd x 3 6 Note that if xd 0 then u Kx which is the control used in the LQR algorithm Figure 3 1 State feedback control loop FLEXGAGE Workbook Student Version v 1 0 3 3 Pre Lab Questions 1 Based on your analysis of the system in the Modeling Laboratory Section 2 3 is the system stable marginally stable or unstable From your experience in Section 2 3 does the stability you determined analyically match how the
6. Flexible Link subsystem contains QUARC blocks that interface with the DC motor and sensors of the system The feedback developed in Section 3 4 1 is implemented using a Simulink Gain block Figure 3 4 q flexgage Simulink diagram used the model IMPORTANT Before you can conduct this experiment you need to make sure that the lab files are configured according to your system setup If they have not been configured already then go to Section 4 5 to configure the lab files first 1 Run the setup flexgage m 2 Ensure the LQR controller you found in Section 3 4 1 is loaded i e gain K 3 Open the q flexgage Simulink diagram Make sure the Manual Switch is set to the Full State Feedback up ward position 4 Go to QUARC Build to build the controller 5 Go to QUARC Start to run the controller The flexible link should be tracking the default 30 degree signal 6 Stop the controller once you have obtained a representative response 7 Plot the responses from the theta deg alpha deg and Vm V scopes in a Matlab figure Similarly as described in Section 3 4 1 the response data is saved in variables data theta data alpha and data vm 8 Measure the settling time and percent overshoot of the measured servo response and the maximum link deflection Does the response satisfy the specifications given in Section 3 1 9 If the specifications have been met then you can proceed to Section 3 4 3 or your report ask your instructo
7. Rotary Flexible Link Workbook FLEXGAGE Student Version Quanser Inc 2011 c 2011 Quanser Inc All rights reserved Quanser Inc 119 Spy Court Markham Ontario L3R 5H6 Canada info quanser com Phone 1 905 940 3575 Fax 1 905 940 3576 Printed in Markham Ontario For more information on the solutions Quanser Inc offers please visit the web site at http www quanser com This document and the software described in it are provided subject to a license agreement Neither the software nor this document may be used or copied except as specified under the terms of that license agreement All rights are reserved and no part may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Quanser Inc ACKNOWLEDGEMENTS Quanser Inc would like to thank Dr Hakan Gurocak Washington State University Vancouver USA for his help to include embedded out comes assessment FLEXGAGE Workbook Student Version 2 CONTENTS 1 Introduction 4 2 Modeling 5 2 1 Background 5 2 2 Pre Lab Questions 10 2 3 Lab Experiments 11 2 4 Results 15 3 Control Design 16 3 1 Specifications 16 3 2 Background 16 3 3 Pre Lab Questions 18 3 4 Lab Experiments 19 3 5 Results 23 4 System Requirements 24 4 1 Overview of Files 25 4 2 Setup for Finding Stiffnes
8. amped system the subsidence ratio i e decrement ratio is defined as 1 n ln O1 On 2 30 where O1 is the peak of the first oscillation and On is the peak of the nth oscillation Note that O1 gt On as this is a decaying response The damping ratio is defined 1 1 2 2 2 31 FLEXGAGE Workbook Student Version v 1 0 2 2 Pre Lab Questions 1 Energy is stored in the flexible link i e the spring as it flexes by an angle of see Figure 2 1 Find the potential energy of the flexible link Use the parameters shown in Figure 2 2 2 Find the total kinetic energy of the system contributed by the rotary servo and the deflection in the link Use the parameters shown in Figure 2 2 3 Compute the Lagrangian of the system 4 Find the first Euler Lagrange equation given in 2 4 Keep the equations in terms of applied torque i e not in terms of DC motor voltage Also make sure your equations follow the general form J x B x Kx u 5 Find the second Euler Lagrange Equation 2 5 6 Find the equations of motion f1 and f2 Assume the viscous damping of the link is negligible i e Bl 0 7 Given state x defined in Equation 2 16 find the linear state space matrices A and B 8 Find the the natural frequency of the response shown in Figure 2 3 if the peak values for the first and fifth oscillation are
9. cies given in step 15 in Section 2 3 2 IV CONCLUSIONS Interpret your results to arrive at logical conclusions for the following 1 How does the model compare with the actual system in step 14 of Section 2 3 2 State space model validation FLEXGAGE Workbook Student Version 28 5 2 Template for Content Control I PROCEDURE 1 Simulation Briefly describe the main goal of the simulation Briefly describe the simulation procedure Section 3 4 1 Briefly describe the procedure in step 4 of Section 3 4 1 to examine the effect of variables on the gain and closed loop response Briefly explain the procedure used to find Q and R in step 8 of Section 3 4 1 2 Full State Feedback Implementation Briefly describe the main goal of this experiment Briefly describe the experimental procedure Section 3 4 2 Briefly explain the procedure used to tune the controller in step 12 of Section 3 4 3 3 Partial State Feedback Implementation Briefly describe the main goal of this experiment Briefly describe the experimental procedure Section 3 4 3 II RESULTS Do not interpret or analyze the data in this section Just provide the results 1 Response plot from step 6 in Section 3 4 1 Full state feedback LQR controller simulation 2 Response plot from step 7 in Section 3 4 2 for Full state feedback LQR controller implementation 3 Response plot from step 10 in Section 3 4 2 for Tuned LQR fu
10. ffness IMPORTANT Before you can conduct this experiment you need to make sure that the lab files are configured according to your system setup If they have not been configured already then you need to go to Section 4 2 to configure the lab files first 1 In the q flexgage id Simulink diagram go to QUARC Build to build the QUARC controller 2 Hold on the SRV02 load gear go to QUARC Start to run the controller and then immediately perturb the flexible link Keep holding the SRV02 base until the controller is done collecting the data The alpha deg Scope should be reading a response similarly as shown in Figure 2 5 Note that the controller is set to run for 5 seconds FLEXGAGE Workbook Student Version v 1 0 Figure 2 5 Typical Flexible Link Free Oscillation Response 3 After the controller stops i e after 5 sec the data is automatically saved in the Matlab workspace to the variable data alpha The time is stored in data alpha 1 vector and the flexible link angle is stored the data alpha 2 vector Plot the response in a Matlab figure 4 Find the natural frequency of the link As in Pre Lab Question 8 the damping in low Therefore assume the damped natural frequency which is being measured is equivalent to the undamped natural frequency 5 Calculate the stiffness of the flexible link Ks Hint Assume the link is a rod when finding the moment of inertia of the link Jl 2 3 2 Model Validation By running a
11. if strcmp CONTROL_TYPE MANUAL Set Q and R matrices to get desired response Q diag 1 1 1 1 R 1 K S E lqr A B Q R FLEXGAGE Workbook Student Version v 1 0 The Q and R are initially set to the default values of Q 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 and R 1 2 These will not give you the desired response but run the script to generate the default gain K Enter the stiffness you found in Section 2 3 1 when prompted 3 Run s flexgage to simulated the closed loop response with this gain See figures 3 3a 3 3b and 3 3c for the typical response a Servo Angle b Flexible Link Angle c Voltage Figure 3 3 Default Simulated Closed Loop Response 4 If Q diag q1 q2 q3 q4 vary each qi independently and examine its effect on the gain and the closed loop response For example when increasing q3 what happens to and Vary each qi by the same order of magnitude and compare how the new gain K changes compared to the original gain Keep R 1 throughout your testing Summarize your results Note Recall your analysis in pre lab Question 3 where the effect of adjusting Q on the generated K was assessed generally by inspecting the cost function equation You may find some discrepancies in this exercise and the pre lab questions 5 Find a Q and R that will satisfy the specifications given in Section 3 1 When doing this don t forget to kee
12. in Matlab and find the folder that contains the s flexgage mdl file 4 Open s flexgage mdl Simulink diagram shown in Figure 3 2 5 Configure the setup flexgage m script according to your hardware See Section 4 3 for more information 6 Run the setup flexgage m script 7 Enter the stiffness Ks you found in Section 2 3 1 4 5 Setup for Flexible Link Control Implementation Before beginning the in lab exercises given in Section 3 4 2 or Section 3 4 3 the q flexgage Simulink diagram and the setup flexgage m script must be setup Follow these steps to get the system ready for this lab 1 Setup the SRV02 with the Flexible Link module as detailed in 7 2 Load the Matlab software 3 Browse through the Current Directory window in Matlab and find the folder that contains the q flexgage mdl file 4 Open the q flexgage mdl Simulink diagram shown in Figure 3 4 5 Configure DAQ Ensure the HIL Initialize block in the SRV02 Flexible Link subsystem is configured for the DAQ device that is installed in your system By default the block is setup for the Quanser Q8 hardware in the loop board See Reference 1 for more information on configuring the HIL Initialize block 6 Configure Sensor The position of the SRV02 load shaft can be measured using the potentiometer or the encoder Set the Pos Src Source block in q flexgage as shown in Figure 3 4 as follows 1 to use the potentiometer 2 to use to the encoder No
13. is case the generalized force acting on the rotary arm is Q1 Beq 2 7 and acting on the link is Q2 Bl 2 8 The torque applied at the base of the rotary arm i e at the load gear is generated by the servo motor as described by the equation gKg mkt Vm Kgkm Rm 2 9 See 4 for a description of the corresponding SRV02 parameters e g such as the back emf constant km The servo damping i e friction Beq opposes the applied torque The flexible link is not actuated the only force acting on the link is the damping Bl Again the Euler Lagrange equations is a systematic method of finding the equations of motion EOMs of a system Once the kinetic and potential energy are obtained and the Lagrangian is found then the task is to compute various derivatives to get the EOMs FLEXGAGE Workbook Student Version 6 2 1 3 Potential and Kinetic Energy Kinetic Energy Translational kinetic equation is defined as T 1 2mv2 2 10 where m is the mass of the object and v is the linear velocity Rotational kinetic energy is described as T 1 2J 2 2 11 where J is the moment of inertia of the object and is its angular rate Potential Energy Potential energy comes in different forms Typically in mechanical system we deal with gravitational and elastic potential energy The relative gravitational potential energy of an object is Vg mg h 2 12 whe
14. l Quanser Flexible Link system 3 4 1 Control Simulation Using the linear state space model of the system and the designed control gain the closed loop response can be simulated This way we can test the controller and see if it satisfies the given specifications before running it on the hardware platform Experiment Setup The s flexgage Simulink diagram shown in Figure 3 2 is used to simulate the closed loop response of the Flexible Link using the LQR control developed in Section 3 3 The Smooth Signal Generator block generates a 0 33 Hz square wave with amplitude of 1 that is passed through a Rate Limiter block to smooth the signal The Amplitude deg gain block is used to change the desired servo position command The state feedback gain K is set in the LQR Control gain block and is read from the Matlab workspace The Simulink State Space block reads the A B C and D state space matrices that are loaded in the Matlab workspace Figure 3 2 s flexgage Simulink diagram used to simulate the state feedback control IMPORTANT Before you can conduct this experiment you need to make sure that the lab files are configured ac cording to your system setup If they have not been configured already go to Section Section 4 4 to configure the lab files first Make sure the model you found in Section 2 3 2 is enterred in FLEXGAGE ABCD eqns student m 1 Open setup flexgage m and go down to the LQR Control section shown here LQR Control
15. ll state feedback controller implementation 4 Response plot from step 6 in Section 3 4 3 for Partial state feedback LQR controller implementation 5 Provide applicable data collected in this laboratory from Table 2 III ANALYSIS Provide details of your calculations methods used for analysis for each of the following 1 Settling time and percent overshoot in step 7 in Section 3 4 1 Full state feedback LQR controller simulation 2 Settling time and percent overshoot in step 8 in Section 3 4 2 for Full state feedback LQR controller imple mentation 3 Settling time and percent overshoot in step 11 in Section 3 4 2 for Tuned LQR full state feedback controller implementation 4 Comparison between partial state and full state feedback in step 7 in Section 3 4 3 IV CONCLUSIONS Interpret your results to arrive at logical conclusions for the following 1 Whether the controller meets the specifications in step 7 in Section 3 4 1 Full state feedback LQR controller simulation 2 Whether the controller meets the specifications in step 8 in Section 3 4 2 for Full state feedback LQR controller implementation 3 Whether the controller meets the specifications in step 11 in Section 3 4 2 for Tuned LQR full state feedback controller implementation FLEXGAGE Workbook Student Version v 1 0 5 3 Tips for Report Format PROFESSIONAL APPEARANCE Has cover page with all necessary details title course student name s
16. owing state space matrices entered A 0 0 1 0 0 0 0 1 0 500 5 0 0 750 5 0 B 0 0 500 500 C zeros 2 4 D zeros 2 1 5 Enter the state space matrices you found in Section 2 2 for A B C and D In Matlab the stiffness and link moment of inertia are defined as Ks and Jl and the SRV02 inertia and damping are denoted Jeq and Beq 6 Run the FLEXGAGE ABCD eqns student m script to load the state space matrices in the Matlab workspace Show the numerical matrices that are displayed in the Matlab prompt 7 The input of the state space model you found in Section 2 2 is the torque acting at the servo load gear or the pivot of the flexible link However we do not control torque directly we control the servo input voltage Recall the voltage torque relationship given in Equation 2 9 in Section 2 1 2 In the System Model section of the setup flexgage m script the actuator dynamics are added to your state space matrices with the code Ao A Bo B B eta_g Kg eta_m kt Rm Bo A 3 3 Ao 3 3 Bo 3 eta_g Kg 2 eta_m kt km Rm A 4 3 Ao 4 3 Bo 4 eta_g Kg 2 eta_m kt km Rm 8 Run the setup flexgage m script again so your Flexible Link model is based on dc motor voltage FLEXGAGE Workbook Student Version v 1 0 9 In the q flexgage val Simulink diagram go to QUARC Build to build the QUARC controller 10 Make sure the area around the Flexible Link experiment is clear Set the Manual Switch to the do
17. p the dc motor voltage within 10 V This control will later be implemented on actual hardware Therefore make sure the actuator is not being saturated Enter the weighting matrices Q and R used and the resulting gain K 6 Plot the responses from the theta deg alpha deg and Vm V scopes in a Matlab figure When the QUARC controller is stopped these scopes automatically save the last 5 seconds of their response data to the variables data theta data alpha and data vm For data theta the time is in data theta 1 the setpoint i e desired SRV02 angle is in data theta 2 and the simulated SRV02 angle is in data theta 3 In the data alpha and data vm variables the 1 holds the time vector and the 2 holds the actual measured data 7 Measure the settling time and percent overshoot of the simulated servo response and the maximum link de flection Does the response satisfy the specifications given in Section 3 1 8 Briefly explain the procedure you used to find Q and R 3 4 2 Control Implementation In this experiment the servo position is controlled while minimizing the link deflection using the LQR based control found in Section 3 4 1 Measurements will then be taken to ensure that the specifications are satisfied FLEXGAGE Workbook Student Version 20 Experiment Setup The q flexgage Simulink diagram shown in Figure 3 4 is used to run the state feedback control on the Quanser Flexible Link system The SRV02
18. position of the SRV02 load shaft can be measured using either the potentiometer or the encoder Set the Pos Src Source block in q flexgage val as shown in Figure 2 6 as follows 1 to use the potentiometer 2 to use to the encoder Note that when using the potentiometer there will be a discontinuity 7 Configure Input Set the Manual Switch to the DOWN position for a step input or the UP position for a square signal 8 Open the setup flexgage m file This is the setup script used for the FLEXGAGE Simulink models 9 Configure setup script When used with the Flexible Link the SRV02 has no load i e no disc or bar and has to be in the high gear configuration Make sure the script is setup to match this setup EXT GEAR CONFIG to HIGH LOAD TYPE to NONE Ensure ENCODER TYPE TACH OPTION K CABLE AMP TYPE and VMAX DAC parameters are set according to the SRV02 system that is to be used in the laboratory CONTROL TYPE to MANUAL 4 4 Setup for Flexible Link Control Simulation Before going through the control simulation in Section 3 4 1 the s flexgage Simulink diagram and the setup flexgage m script must be configured Follow these steps to configure the lab properly 1 Load the Matlab software FLEXGAGE Workbook Student Version 26 2 IMPORTANT Make sure the model you found in Section 2 3 2 is enterred in FLEXGAGE ABCD eqns student m 3 Browse through the Current Directory window
19. r If they have not been met then you need to tweak your controller Using the principles you learnt in Section 3 4 1 tune the current Q and R matrices to satisfy the specifications Enter the weighting matrices Q and R used and the resulting gain K 10 Plot the responses from the theta deg alpha deg and Vm V scopes in a Matlab figure of your newly tuned controller Similarly as described in Section 3 4 1 the response data is saved in variables data theta data alpha and data vm 11 Measure the settling time and percent overshoot of the simulated servo response and the maximum link de flection Does the response satisfy the specifications given in Section 3 1 12 Explain the procedure you used to tune your controller FLEXGAGE Workbook Student Version v 1 0 3 4 3 Implementing Partial State Feedback Control In this section the partial state feedback response of the system is assessed and compared with the full state feedback control in Section 3 4 2 1 Run the setup flexgage m 2 Ensure the LQR control gain you settled on in Section 3 4 2 is loaded i e gain K 3 Open the q flexgage Simulink diagram Make sure the Manual Switch is set to the Partial State Feedback downward position 4 Go to QUARC Start to run the controller The flexible link should be tracking the default 30 degree signal 5 Stop the controller once you have obtained a representative response 6 As in Section 3 4 2 attach a Ma
20. re m is the object mass and h is the change in altitude of the object from a reference point The potential energy of an object that rises from the table surface i e the reference up to 0 25 meter is h 0 25 0 0 25 and the energy stored is Vg 0 25mg The equation for elastic potential energy i e the energy stored in a spring is Ve 1 2K x2 2 13 where K is the spring stiffness and x is the linear or angular change in position If an object that is connected to a spring moves from in its initial reference position to 0 1 m then the change in displacement is x 0 1 0 0 1 and the energy stored equals Ve 0 005K 2 1 4 Linear State Space Model The linear state space equations are x Ax Bu 2 14 and y Cx Du 2 15 where x is the state u is the control input A B C and D are state space matrices For the Rotary Flexible Link system the state and output are defined x 2 16 and y x1 x2 2 17 In the output equation only the position of the servo and link angles are being measured Based on this the C and D matrices in the output equation are C 1 0 0 0 0 1 0 0 2 18 and D 0 0 2 19 The velocities of the servo and link angles can be computed in the digital controller e g by taking the derivative and filtering the result though a high pass filter FLEXGAGE Workbook Student Version v 1 0
21. s 25 4 3 Setup for Model Validation 26 4 4 Setup for Flexible Link Control Simulation 26 4 5 Setup for Flexible Link Control Implementation 27 5 Lab Report 28 5 1 Template for Content Modeling 28 5 2 Template for Content Control 29 5 3 Tips for Report Format 30 FLEXGAGE Workbook Student Version v 1 0 1 INTRODUCTION The objective of this experiment is to control the position of the servo while minimizing the motions the flexible rotary link Topics Covered Modeling the Rotary Flexible Link using Lagrange Find the linear state space model of the system Do some basic model validation Design an state feedback controller using Linear Quadratic Regulator LQR algorithm through simulation Implement the designed LQR controller on the device Compare the simulated and measured closed loop results Assess the behaviour of implementing a partial state feedback controller Prerequisites In order to successfully carry out this laboratory the user should be familiar with the following Basics of Simulink Transfer function fundamentals State space modeling e g obtaining state equations from a set of differential equations SRV02 QUARC Integration Laboratory 2 in order to be familiar using QUARC with the SRV02 FLEXGAGE Workbook Student Version 4 2 MODELING 2 1 Background 2 1 1 Model The Rotary Flexible Link model i
22. s e g NI USB 6251 NI PCIe 6259 For a full listing of compliant DAQ cards see Reference 1 Quanser SRV02 ET rotary servo Quanser Rotary Flexible Joint attached to SRV02 Quanser VoltPAQ X1 power amplifier or equivalent Before Starting Lab Before you begin this laboratory make sure QUARC is installed on your PC as described in 3 The QUARC Analog Loopback Demo has been ran successfully SRV02 Rotary Flexible Joint and amplifier are connected to your DAQ board as described Reference 7 FLEXGAGE Workbook Student Version 24 4 1 Overview of Files File Name Description Flexible Link User Manual pdf This manual describes the hardware of the Rotary Flexi ble Link system and explains how to setup and wire the system for the experiments Flexible Link Workbook Student pdf This laboratory guide contains pre lab questions and lab experiments demonstrating how to design and implement a position controller on the Quanser SRV02 Flexible Link plant using QUARC setup flexgage m The main Matlab script that sets the SRV02 motor and sensor parameters the SRV02 configuration dependent model parameters and the Flexible Link i e flexgage sensor parameters Run this file only to setup the labora tory config srv02 m Returns the configuration based SRV02 model specifica tions Rm kt km Kg eta g Beq Jeq and eta m the sensor calibration constants K POT K ENC and K TACH
23. s shown in Figure 2 1 The base of the flexible link is mounted on the load gear of the SRV02 system The servo angle increases positively when it rotates counter clockwise CCW The servo and thus the link turn in the CCW direction when the control voltage is positive i e Vm gt 0 The flexible link has a total length of Ll a mass of ml and its moment of inertia about the center of mass is Jl See the Rotary Flexible Link User Manual in 7 for the values of these parameters The deflection angle of the link is denoted as and increases positively when rotated CCW Figure 2 1 Rotary Flexible Link Angles The flexible link system can be represented by the diagram shown in Figure 2 2 Our control variable is the input servo motor voltage Vm This generates a torque at the load gear of the servo that rotates the base of the link The viscous friction coefficient of the servo is denoted by Beq This is the friction that opposes the torque being applied at the servo load gear The friction acting on the link is represented by the viscous damping coefficient Bl Finally the flexible link is modeled as a linear spring with the stiffness Ks Figure 2 2 Rotary Flexible Link Model FLEXGAGE Workbook Student Version v 1 0 2 1 2 Finding the Equations of Motion Instead of using classical mechanics the Lagrange method is used to find the equations of motion of the system This systematic method is often used for more complicated
24. simulation and the actual device in parallel we can verify whether the dynamic model which drives the simulation accurately represents our system Experimental Setup The q flexgage val Simulink diagram shown in Figure 2 6 applies either a step or pulse input to both the Quanser Flexible Link hardware and to the Flexible Link model and reads the servo and link angles The SRV02 Flexible Link subsystem contains the QUARC blocks that interface to the actual hardware The Simulink State Space block reads the A B C and D state space matrices that are loaded in the Matlab workspace This model outputs the deflection angle of the link IMPORTANT Before you can conduct this experiment you need to make sure that the lab files are configured according to your system setup If they have not been configured already then go to Section 4 3 to configure the lab files first 1 Run the setup flexgage m 2 When prompted enter the stiffness you found in Section 2 3 1 This is saved to the Matlab variable Ks Enter link stiffness Ks 3 Depending on your stiffness the Matlab prompt should generate a gain similarly as shown below this gain is generated for a Ks of 1 FLEXGAGE Workbook Student Version 12 Figure 2 6 q flexage val Simulink diagram used validate the model K 1 0000 8 7209 0 6264 0 3958 This means the script ran correctly 4 In Matlab open the M File called FLEXGAGE ABCD eqns student m The script has the foll
25. st to see how well your model represents the actual device As shown in figures 2 7a and 2 7b the simulation does not match the measured response perfectly 15 Give at least one reason why the model does not represent the system accurately 16 In Matlab find the open loop poles i e eigenvalues of the system using the state space matrix A that is loaded Note These will be required for a pre lab question in Section 3 3 FLEXGAGE Workbook Student Version 14 2 4 Results Fill out Table 1 with your answers from your modeling lab results both simulation and implementation Description Symbol Value Unit Finding Stiffness Natural frequency n rad s Stiffness Ks N m rad Model Validation State Space Matrix A State Space Matrix B State Space Matrix C State Space Matrix D Open loop poles OL Table 1 Results FLEXGAGE Workbook Student Version v 1 0 3 CONTROL DESIGN 3 1 Speci cations The time domain requirements are Specification 1 Servo angle settling time ts lt 0 5 s Specification 2 Servo angle percentage overshoot PO lt 7 5 Specification 3 Maximum link angle deflection lt 10 deg Specification 4 Maximum control effort voltage Vm lt 10 V These specifications are to be satisfied when the rotary arm is tracking a 30 degree angle square wave 3 2 Background In Section 2 2 we found a linear state state space model that represents the Ro
26. systems such as robot manipulators with multiple joints More specifically the equations that describe the motions of the servo and the link with respect to the servo motor voltage i e the dynamics will be obtained using the Euler Lagrange equation 2L t qi L qi Qi 2 1 The variables qi are called generalized coordinates For this system let q t t t 2 2 where as shown in Figure 2 2 t is the servo angle and t is the flexible link angle The corresponding velocities are q t t t t t 2 3 Note The dot convention for the time derivative will be used throughout this document i e d dt and d dt The time variable t will also be dropped from and i e t and t With the generalized coordinates defined the Euler Lagrange equations for the rotary flexible link system are 2L t L Q1 2 4 and 2L t L Q2 2 5 The Lagrangian of a system is defined L T V 2 6 where T is the total kinetic energy of the system and V is the total potential energy of the system Thus the Lagrangian is the difference between a system s kinetic and potential energies The generalized forces Qi are used to describe the non conservative forces e g friction applied to a system with respect to the generalized coordinates In th
27. t1 1 12 and t5 1 71 seconds Because the damping is low assume the damped and undamped natural frequency are equivalent FLEXGAGE Workbook Student Version 10 2 3 Lab Experiments In the first part of this laboratory the stiffness of the flexible link is determined by measuring its natural frequency In the second part the state space model is finalized and validated against actual measurements 2 3 1 Finding Stiffness In Section 2 1 5 we found an equation describing the free oscillation response of a second order system This can also be used to describe the response of the flexible link when initially perturbed and left to decay Physical Parameters for the Lab In order to do some of the laboratory exercises you will need these values Beq 0 004 N m rad s Jeq 2 08 10 3 kg m2 ml 0 065 kg Ll 0 419 m Note The equivalent viscous damping Beq and moment of inertia Jeq parameters are for the SRV02 when there is no load i e the parameter found in the SRV02 Modeling Laboratory was for servo with the disc load Experimental Setup The q flexgage id Simulink diagram shown in Figure 2 4 is used to find the natural frequency of the flexible link The QUARC blocks are used to interface with strain gage sensor of the system For more information about QUARC see Reference 2 This model outputs the deflection angle of the link Figure 2 4 q flexage id Simulink diagram used to find link sti
28. tary Flexible Link system This model is used to investigate the stability properties of the Flexible Link system in Section 3 2 1 In Section 3 2 2 the notion of controllability is introduced Using the Linear Quadratic Regular algorithm or LQR is a common way to find the control gain and is discussed in Section 3 2 3 Lastly Section 3 2 4 describes the state feedback control used to control the servo position while minimizing link deflection 3 2 1 Stability The stability of a system can be determined from its poles 8 Stable systems have poles only in the left hand plane Unstable systems have at least one pole in the right hand plane and or poles of multiplicity greater than 1 on the imaginary axis Marginally stable systems have one pole on the imaginary axis and the other poles in the left hand plane The poles are the roots of the system s characteristic equation From the state space the characteristic equation of the system can be found using det sI A 0 3 1 where det is the determinant function s is the Laplace operator and I the identity matrix These are the eigenvalues of the state space matrix A 3 2 2 Controllability If the control input u of a system can take each state variable xi where i 1 n from an initial state to a final state then the system is controllable otherwise it is uncontrollable 8 Rank Test The system is controllable if the rank of its controllability
29. te that when using the potentiometer there will be a discontinuity 7 Configure setup script Set the parameters in the setup flexgage m script according to your system setup See Section 4 3 for more details 8 Run the setup flexgage m script FLEXGAGE Workbook Student Version v 1 0 5 LAB REPORT This laboratory contains two groups of experiments namely 1 Modeling the Quanser Rotary Flexible Link system and 2 State feedback control using LQR For each experiment follow the outline corresponding to that experiment to build the content of your report Also in Section 5 3 you can find some basic tips for the format of your report 5 1 Template for Content Modeling I PROCEDURE 1 Finding Stiffness Briefly describe the main goal of the experiment Briefly describe the experiment procedure Section 2 3 1 2 Model Validation Briefly describe the main goal of the experiment Briefly describe the experiment procedure Section 2 3 2 II RESULTS Do not interpret or analyze the data in this section Just provide the results 1 Free oscillation plot from step 3 in Section 2 3 1 2 Model validation plot from step 13 in Section 2 3 2 3 Provide applicable data collected in this laboratory from Table 1 III ANALYSIS Provide details of your calculations methods used for analysis for each of the following 1 Measured link stiffness in step 5 in Section 2 3 1 2 Model discrepan
30. tlab figure representing the SRV02 angle and flexible link angle response as well as the input voltage 7 Examine the difference between the partial state feedback PSF response and the full state feedback FSF response Explain why PSF control behaves this way by looking at the q flexgage Simulink diagram FLEXGAGE Workbook Student Version 22 3 5 Results Fill out Table 2 with your answers from your control lab results both simulation and implementation Description Symbol Value Unit LQR Simulation LQR Weighting Matrices Q R LQR Gain K Settling time ts s Percentage overshoot PO Maximum deflection max deg LQR Implementation LQR Weighting Matrices Q R LQR Gain K Settling time ts s Percentage overshoot PO Maximum deflection max deg Table 2 Results FLEXGAGE Workbook Student Version v 1 0 4 SYSTEM REQUIREMENTS Required Software Microsoft Visual Studio Matlab with Simulink Real Time Workshop and the Control System Toolbox QUARC 2 1 or later See the QUARC software compatibility chart at 5 to see what versions of MS VS and Matlab are compatible with your version of QUARC and for what OS Required Hardware Data acquisition DAQ card that is compatible with QUARC This includes Quanser Hardware in the loop HIL boards such as Q2 USB Q8 USB QPID QPIDe and some National Instruments DAQ device
31. wnward position to feed a Step input 11 Go to QUARC Start to run the q flexgage val controller Typical scope responses are shown in Figure 2 7a and Figure 2 7b The theta deg scope displays the simulated servo angle in yellow and the measured angle in purple Similarly the alpha deg scope shows the simulated link angle in yellow and the measured angle in purple a Servo Angle b Flexible Link Angle Figure 2 7 Typical Flexible Link Model Validation Response 12 If your simulation and measured response match go to the next step If they do not then there is an issue with your model Here are some issues to investigate Ensure the state space model was enterred properly in the script The stiffness Ks found in Section 2 3 1 is not correct Review your calculations or redo the experiment Review your model derivation in Section 2 2 e g might be a mistake in solving the EOMs 13 The theta deg and alpha deg scopes save their data to the variables data theta and data alpha For data theta the time is in data theta 1 the simulated servo angle is in data theta 2 and the measured SRV02 angle is in data theta 3 Similarly for the flexible link response saved in data alpha Plot the re sponse in a Matlab figure 14 How well does your model represent the actual system We want a model that is fairly representative but having said that keep in mind that no model is perfect This is just a quick te
32. xible Link User Manual 7 2 Load the Matlab software 3 Browse through the Current Directory window in Matlab and find the folder that contains the file q flexgage id mdl 4 Open the q flexgage id mdl Simulink diagram shown in Figure 2 4 FLEXGAGE Workbook Student Version v 1 0 5 Configure DAQ Ensure the HIL Initialize block subsystem is configured for the DAQ device that is installed in your system By default the block is setup for the Quanser Q8 hardware in the loop board See Reference 1 for more information on configuring the HIL Initialize block 4 3 Setup for Model Validation Before performing the in lab exercises in Section 2 3 2 the q flexgage val Simulink diagram and the setup flexgage m script must be configured Follow these steps to get the system ready for this lab 1 Setup the SRV02 with the Flexible Link module as detailed in 7 2 Load the Matlab software 3 Browse through the Current Directory window in Matlab and find the folder that contains the QUARC FLEX GAGE file q flexgage val mdl 4 Open the q flexgage val mdl Simulink diagram shown in Figure 2 6 5 Configure DAQ Ensure the HIL Initialize block in the SRV02 Flexible Link subsystem is configured for the DAQ device that is installed in your system By default the block is setup for the Quanser Q8 hardware in the loop board See Reference 1 for more information on configuring the HIL Initialize block 6 Configure Sensor The