Home
IAR-7002-WG User`s Manual
Contents
1. Obtain an IP address Select this option if you want the IP address of the WAN port to be Use the following IP Select this option if you want to assign an IP address to the WAN address port manually You should set IP Address Subnet Mask and Default Gateway according to IP rules Obtain DNS server Obtains a DNS server address from a DHCP server If you have address chosen to obtain an IP address automatically this option will be automatically selected accordingly Use the following opecifies a DNS server address manually You can enter two DNS server addresses as the primary and secondary options addresses Use Modem 3G as Enable this option if you want to use Modem 3G as a backup backup connection connection when main connection is lost ORing Industrial Networking Corp 18 ORing TGAR 1062 2062 1662 Series User Manual Enter your account username and password in the corresponding fields Type a website address such as joogle com in Ping Test Site to use it to check if the connection is alive or lost WAN Connection Type as PPPoE PPPoE v User Name Enter the username amp password provided by your ISP Password Enter the service name provided by your ISP Enter the name of the access concentrator provided by your ISP Specify the IP amp DNS Enter a static IP and DNS address required by other ISPs provided by ISP Auto connect automatically when the router boot
2. k 5 52 Bpom 54 Dra S i e ROUTE 55 SEE LA RAP 55 OO 55 ae SES T 55 LA cca IR EE 56 TEGMAICAl SOCCHICATIONS eee 57 COMDHANC ee C C C C 62 ORing Industrial Networking Corp 3 ORing Getting Started 1 1 About TGAR 1062 2062 1662 Series Designed for industrial and rolling stock wireless applications with two LAN ports in M12 connectors and EN50155 compliance the ORing TGAR 1062 2062 1662 series are IEEE802 11 a b g n routers capable of providing a fast and effective way to communicate with the Internet over wired or wireless LANs Consisting of 3G and 4G models the series of devices can be configured to operate in 3 modes of routing function dynamic static IP route PPPoE authentication and cellular modem dial up Users TGAR 1062 2062 1662 Series User Manual can set up WLAN environment to fulfill demands of various applications rapidly by dialing up cellular modem With dual Ethernet ports in switch mode you can use Daisy Chain to reduce the usage of Ethernet switch ports The router also provides VPN capabilities which create encrypted virtual tunnels on the Internet allowing remote or mobile users to connect to the network of your office 1 2 Software Features B High speed air connectivity for up to 300Mbps B High security with support for W
3. TI 11 run MEC ie e le Te ee ee eens 11 ee FM VAY NU UU UU sa a ee 11 3 2 3 Redundant Power Inputs iii 12 Cables and Antenna 1 eeeeeee eese enean nnne na nnnm R manua anna uaa 13 4 1 ET SUS Pin D eo a dvd de cas cn nn 13 4 2 Console Porn Pri le De EE 13 4 3 DDO 14 4 4 VWIFBIBSS ATIIO IR 14 4 5 Gaar at ul E D 15 Management EE 16 5 1 Network Connection ES ee eau de ee 16 5 2 OO de E 17 NR e Le E 17 NEE 18 A I EE T 22 ple HO 22 WMC SS ew T 24 pp 30 Re ln 30 ON NO nope idle eo Oo en en nn eee S 31 Wireless Setting Advanced Settings 31 Wireless Setting MAC Filter iii 33 NAT Setting Virtual Server iii 34 NAT ue p HA 35 DAT CUTI UP EE 35 ORing Industrial Networking Corp 2 ORing TGAR 1062 2062 1662 Series User Manual Wl RTE lee VO Mean OO 36 Firewall Setting MAC Filter 37 VON Sn OPEN on NETS 38 Vom Sen ed sind Aui 40 VDS rigo d uda ESI EROR m 42 iin 43 Routing Protocol Routing Setting ccceccceecceeeeeeeeseeeseeeeeeeeseeeseeeseueeeeeeaeeeseeesaues 45 92 0 3SVSIOID e 48 L3 dn Le BE 48 Router Restart EM 48 BAR Te DUE OE avos eia tuia o qeu um Min DN eee eae 49 Save Restore Configurations iii 49 KICO MOO CNRC 50 EV Chil EE 50 El
4. TGAR 1062 2062 1662 Series IEEE 802 11 a b g n Access Point Router User Manual Version 1 0 Feb 2014 www oring networking com ORing Industrial Networking Corp ORing TGAR 1062 2062 1662 Series User Manual COPYRIGHT NOTICE Copyright 2014 ORing Industrial Networking Corp All rights reserved No part of this publication may be reproduced in any form without the prior written consent of ORing Industrial Networking Corp TRADEMARKS ORing is a registered trademark of ORing Industrial Networking Corp All other trademarks belong to their respective owners REGULATORY COMPLIANCE STATEMENT Product s associated with this publication complies comply with all applicable regulations Please refer to the Technical Specifications section for more details WARRANTY ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date 5 years for most products ORing will repair or replace products found by ORing to be defective within this warranty period with shipment expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warranty does not apply to ORing products that are misused abused improperly installed or damaged by accidents Please refer to the Technical Specifications section for the actual warranty period s of the p
5. SNMP iJ Device Event Notification Hardware Reset Cold Start Software Reset Warm Start Login Failed IP Address Changed Password Changed Redundant Power Changed Eth Link 5tatus Changed SNMP Access Failed Wireless Client Associated Wireless Client Disassociated Client Mode Associated Client Mode Disassociated Client Mode Roaming Fault Event Notification Power 1 Fault Power 2 Fault Eth Link Down DI1 ON gt OFF DI ON gt OFF DI3 ON gt OFF DI4 ON gt OFF DIL OFF DI OFF DIS OFF DI4 OFF ORing Industrial Networking Corp 53 ORing TGAR 1062 2062 1662 Series User Manual SNMP Agent SNMP Simple Network Management Protocol Agent is a service program that runs on the access point The agent provides management information to the NMS by keeping track of various operational aspects of the AP system You can enable or disable the function SNMP Trap Enter the IP address of the SNMP server which will send out traps Server 1 4 generated by the AP Community Community is a password to establish trust between managers and agents Normally public is used for read write community SysLocation Specifies sysLocation string SysContact Specifies sysContact string Relay Fault LED Relay Power 1 Fault Power 2 Fault POE Fault Eth Link Down DI1 ON gt OFF DI2 ON gt OFF DI3 ON gt OFF DI4 ON gt OFF DI1 OFF gt ON DI2 OFF gt ON DI3 OFF gt ON DI4 OFF gt ON DI
6. 85dBm 2dBm 11Mbps 11g 68dBm 2dBm 54Mbps Receiver Sensitivity 11gn HT20 68dBm 2dBm 150Mbps Lion HT40 68dBm 2dBm 300Mbps 11an HT20 68dBm 2dBm 150Mbps 11an HT40 68dBm 2dBm 300Mbps WEP 64 bit 128 bit key supported WPA WPA2 802 11i WEP and AES encryption Frequency Band Encryption Security WPAPSK 256 bit key pre shared key supported 802 1X Authentication supported TKIP encryption Wireless Security SSID broadcast disable Cellular Interface GSM GPRS EGPRS EDGE WCDMA HSDPA HSUPA GSM GPRS EGPRS GSM GPRS EGPRS GSM GPRS EGPRS EDGE EDGE WCDMA HSDPA EDGE WCDMA HSDPA WCDMA HSDPA HSUPA HSUPA HSPA LTE HSUPA HSPA LTE Cellular Standard Antenna Connector 1 x RP SMA Female 1 x SMA Female 2 x RP SMA Female 2 x SMA Female ORing Industrial Networking Corp 5 ORing TGAR 1062 2062 1662 Series User Manual America US LTE 700 1700 2100 MHz UMTS HSDPA HSUPA H SPA DC HSPA America US LTE 700 1700 2100 MHz UMTS HSDPA HSUPA HSPA DC HSPA MHz 2900 2800 MHz oe Dual band GSM GPRS EDGE Quad band GSM GPRS EDGE 1900 2100 MHz GSM GPRS EDGE 850 900 1800 1900 Quad band 850 900 1800 1900 850 900 1800 1900 MHz GSM GPRS EDGE MHz MHz Europe EU Europe EU 850 900 1800 1900 MHz eg Gg LTE WCDMA HSDPA 850 900 1900 2100 MHz 850 900 1900 2100 eap MO 800 900 1800 2100 2 MHz 600 MHz MHz UMTS HSDPA HSUPA HSPA U
7. e 191 PIED WIS 4 LINY JE nia UU TGAR 2062 Series ORing Industrial Networking Corp 7 ORing TGAR 1062 2062 1662 Series User Manual Hardware Installation AN Elevated Operating Ambient If installed in a closed environment make sure the operating ambient temperature is compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Make sure the amount of air flow required for safe operation of the equipment is not compromised during installation Mechanical Loading Make sure the mounting of the equipment is not in a hazardous condition due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern 3 1 Wall Mounting Installation TGAR 1062 Series Wall mount Kit Measurement ORing Industrial Networking Corp 8 ORing TGAR 1062 2062 1662 Series User Manual 125 6 11648 pot WIS i LAY pieni gpuu ez Transporter menia POAR TT 10 12 GEN WIFI ANT 1 PILAM anna m LU Na BS F TGAR 2062 Series Wall mount Kit Measurement ORing Industrial Networking Corp 9 ORing TGAR 1062 2062 1662 Series User Manual 125 6 VIE PAS MIS D 4 ANY
8. 2dBm 150Mbps Lion HT40 68dBm 2dBm 300Mbps 11an HT20 68dBm 2dBm 150Mbps Lian HT40 68dBm 2dBm 300Mbps WEP 64 bit 128 bit key supported WPA WPA2 802 11i WEP and AES encryption Frequency Band Encryption Security WPAPSK 256 bit key pre shared key supported 802 1X Authentication supported TKIP encryption Wireless Security SSID broadcast disable ORing Industrial Networking Corp 59 ORing TGAR 1062 2062 1662 Series User Manual Cellular Interface GSM GPRS EGPRS EDGE WCDMA GSM GPRS EGPRS EDGE WCDMA HSDPA HSUPA HSPA Cellular Standard HSDPA HSUPA LTE Antenna Connector 1 x Reverse SMA Female 1 x SMA Female America US LTE 700 1700 2100 MHz UMTS HSDPA HSUPA HSPA DC HSPA 800 850 1900 2100 MHz GSM GPRS EDGE 850 900 1800 1900 MHz Europe EU LTE WCDMA HSDPA 850 900 1900 2100 MHz 800 900 1800 2100 2600 MHz UMTS HSDPA HSUPA HSPA DC HSPA 900 2100 MHz GSM GPRS EDGE Dual band HSUPA 1900 2100 MHz Quad band GSM GPRS EDGE 850 900 1800 1900 MHz Band Option 900 1800 1900 MHz Protocol Support Protocol ARP BOOTP DHCP DNS HTTP IP ICMP SNTP TCP UDP RADIUS SNMP PPPoE STP IEEE 802 1D Fault contact Relay Relay output to carry capacity of 1A at 24VDC Power Redundant Input Power Dual Power Inputs 12 48 VDC on M23 connector 24 VDC Typ Power Consumption Typ 13 Watts 14 Watts LED indicators Power Indicator Overl
9. 4 6 CS EN61000 4 8 EN61000 4 11 ORing Industrial Networking Corp 58 ORing TGAR 1062 2062 1662 Series User Manual Safety EN60950 1 Warranty 5 years ORing WLAN Access Point Model TGAR 1662 M12 3G TGAR 1662 M12 4G Physical Ports 10 100 1000Base T X Ports in M12 Auto MDI MDIX 8 pin A coding DIDO port in M12 5 pin A coding 2 DI x 4 and DO x 4 RS 232 Console port in M12 115200 8 N 1 5 pin A coding Relay port in M12 5 pin A coding 1A 24VDC WLAN interface Antenna Connector 4 x reverse SMA type antenna connector Radio Frequency Type DSSS OFDM IEEE802 11a OFDM with BPSK QPSK QAM 64QAM IEEE802 11b CCK DQPSK DBPSK Modulation IEEE802 11g OFDM with BPSK QPSK 16QAM 64QAM IEEE802 11n BPSK QPSK 16 QAM 64 QAM America FCC 2 412 2 462 GHz 11 channels 5 180 5 240 GHz amp 5 745 5 825 GHz 9 channels Europe CE ETSI 2 412 2 472 Ghz 13 channels 5 180 5 240 GHz 4 channels IEEE802 11b 1 2 5 5 11 Mbps Transmission Rate IEEE802 11a g 6 9 12 18 24 36 48 54 Mbps IEEE801 11n up to 300Mbps 11a 12dBm 1 5dBm 11b 18dBm 1 5dBm 11g 15dBm 1 5dBm Transmit Power 11gn HT20 13dBm 1 5dBm 150Mbps 1ign HT40 12dBm 1 5dBm 300Mbps 11an HT20 12dBm 1 5dBm 150Mbps 11an HT40 12dBm 1 5dBm 300Mbps 11a 68dBm 2dBm 54Mbps 11b 85dBm 2dBm 11Mbps 11g 68dBm 2dBm 54Mbps Receiver Sensitivity 11gn HT20 68dBm
10. A login window will pop up where you can enter the default login name admin and password admin For security reasons we strongly recommend you to change the password Click on System Tools Login Setting after logging in to change the password ORing Industrial Networking Corp 16 ORing TGAR 1062 2062 1662 Series User Manual Address 192 168 10 1 Remember my password Cancel After you log in successfully a Web interface will appear as shown below On the left hand side of the interface is a list of functions where you can configure the settings The details of the configurations will be shown on the right screen Industrial EN50155 IEEE 802 11 a b g n 3G Cellular Router with 2x10 100 1000Base T X M12 connector US Band 5 2 Configuration On top of the Home screen shows information about the firmware version uptime and WAN IP address Industrial EN50155 IEEE 802 11 a b g n 3G Cellular Router with 2x10 100 1000Base T X M12 connector US Band yste ools System Status Ey Logout 5 2 1 Basic Setting This section will guide you through the general settings for the router ORing Industrial Networking Corp 17 ORing TGAR 1062 2062 1662 Series User Manual WAN This page allows you to configure WAN settings Different WAN connection types will have different settings WAN Connection Type as Dynamic Static IP DynamicStatic IP ve 0 0 0 0 QUO
11. Client PC WAN PC Server PC ee ee amp O Disconnect ORing Industrial Networking Corp 42 ORing TGAR 1062 2062 1662 Series User Manual PPTP Client Enables or disables PPTP client Server IP Hostname Enter the server IP address or hostname Username Password Enter the username and password assigned by PPTP server Choose the rules to be applied Reconnect on failure prompts automatic reconnection when the link fails Require chap check to use chap authentication on your PPTP server Require mschap check to use mschap authentication on your PPTP server Require mschap v2 check to use mschap v2 authentication on your PPTP server Require MPPE check to use MPPE Microsoft Point to Point Encryption encryption on data transmitted through PPP Point to Point Protocol and VPN links Click Connect to link to the server or Disconnect to disconnect from Operations the server Link Status Show the status of the link VRRP A VRRP Virtual Router Redundancy Protocol is a computer networking protocol aimed to eliminate the single point of failure by automatically assigning available IP routers to participating hosts Using a virtual router ID VRID address and virtual router IP VRIP address to represent itself a virtual router consists of two or more physical routers including one master router and one or more backup routers All routers in the virtual router group share the same VRID and VRIP The master router provide
12. In this mode the AP will act as a central connection point which other wireless clients can connect to ORing Industrial Networking Corp 24 ORing TGAR 1062 2062 1662 Series User Manual The index of the SSID SSID index SSID Service Set Identifier is a unique name that identifies a network All devices on the network must be set with the same SSID in order to communicate with each other Fill in a new SSID in this field if you do not want to use the default value opecify a channel to be used Channel 6 is the default channel You can also select a new number from the dropdown list All Channel devices on the network must be set to use the same channel to communicate on the network A WDS master is the central control point for authenticating wireless clients caching client key material distributing MFP key material reporting radio management information to an WDS Master Mode upstream network management station and updating other APs participating in WDS You can set the device as the WDS master by selecting from the list This function prevents devices connected to an AP from AP Isolation communicating directly with each other This function is useful when many wireless clients request your network frequently You can choose the security type for your WLAN connection from the following options None no encryption Security options l l WEP WEP Wired Equivalent Privacy is a wireless security protoc
13. Open VPN Server and Client Connection D lagnos lS Diagnosis ORing Industrial Networking Corp 39 ORing TGAR 1062 2062 1662 Series User Manual Open VPN Server Enables or disables the function of Open VPN server Tunnel Protocol Select UDP or TCP protocol depending on your needs TCP is more reliable than UDP but UDP performs better than TCP It is recommended to use UDP if the distance between VPN server and client is short otherwise use TCP Port 0 The number of the port default is 1194 LZO Compression Enables or disables the function of LZO Compression Keys Setting Select Auto to use preset certificates or Manual to use your certificates Please install openvpn client software to generate your certificates and paste them here For more information please visit openvpn website Open VPN Client Enables or disables the function of Open VPN client Enter the Open VPN server IP address Tunnel Protocol Select UDP or TCP protocol depending on your needs TCP is more reliable than UDP but UDP performs better than TCP It is recommended to use UDP if the distance between VPN server and client is short otherwise use TCP Pot 00 The number of the port default is 1194 LZO Compression Enables or disables the LZO Compression Keys Setting Select Auto to use preset certificates or Manual to use your certificates Please install openvpn client software to generate your certificates and paste them here For more i
14. device A correct date and time will help the system log events You can set up a NTP Network Time Protocol client to synchronize date amp time with a NTP server on the Internet ORing Industrial Networking Corp 30 ORing TGAR 1062 2062 1662 Series User Manual Synchronize opecify the scheduled time for synchronization Local Date oet a local date manually Local Time Set a local time manually Get Current Date amp Click to set the time from your browser Time from Browser 5 2 2 Networking Setting This section will guide you through various networking settings including wireless NAT firewall VPN VRRP and routing protocol Wireless Setting Advanced Setting This page allows you to set up wireless configuration Radio Button Enables or disables wireless function Beacon Interval A beacon is a packet sent by a wireless access point to synchronize wireless devices The beacon interval value indicates ORing Industrial Networking Corp 31 ORing TGAR 1062 2062 1662 Series User Manual the frequency interval of the beacon Increasing the beacon interval reduces the number of beacons and the overhead associated with them The default value is 100 but 50 is recommended when reception is poor DTIM Interval A DTIM interval determines how often a beacon frame includes a Delivery Traffic Indication message a message that informs the clients about the presence of buffered multicast oroadcast data on th
15. e x sene Dimension Unit mm GO mi LJ D T ORing ze Transporter m TGAH 15562 45 M12 3 50 PARI EAH Relay Gutpui FAARF ETH ALAH UE LAN AC d SCHER O ETH ETH E gen T E wy j H 1 E a ik WIFI ANT 1 WIFI ANT 1 innan 12 5 56 5 19 17 65 TGAR 1662 Series Wall mount Kit Measurement The device can be fixed to the wall Follow the steps below to install the device on the wall Step 1 Hold the router upright against the wall Step 2 Insert four screws through the large opening of the keyhole shaped apertures at the top and bottom of the unit and fasten the screw to the wall with a screwdriver Step 3 Slide the router downwards and tighten the four screws for added stability ORing Industrial Networking Corp 10 ORing TGAR 1062 2062 1662 Series User Manual Instead of screwing the screws in all the way it is advised to leave a space of about 2mm to allow room for sliding the switch between the wall and the screws 3 2 Wiring WARNING Be sure to switch off the power and make sure the area is not hazardous before disconnecting modules or wires The devices may only be connected to the supply voltage shown on the type plate 3 2 1 Grounding Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground pin on the power connector to t
16. of all wireless clients connected Mac Address Rx Bytes Rx Packets Tx Bytes Tx Packets Rssi Quality Tx Bitrate Link Type ORing Industrial Networking Corp 56 ORing TGAR 1062 2062 1662 Series User Manual Technical Specifications ORing WLAN Access TGAR 1062 M12 3G TGAR 1062 M12 4G TGAR 2062 M12 3G TGAR 2062 M12 3G Point Model Physical Ports 10 100 1000Base T X Ports in M12 Auto MDI MDIX 8 pin A coding DIDO port in M12 5 pin 2 DI x 4 and DO x 4 A coding RS 232 Console port in M12 115200 8 N 1 5 pin A coding Rela ort in M12 5 pin Yi p GA 1A 24VDC A coding WLAN interface Antenna Connector 2 x reverse SMA type antenna connector Radio Frequency Type DSSS OFDM IEEE802 11a OFDM with BPSK QPSK QAM 64QAM IEEE802 11b CCK DQPSK DBPSK Modulation IEEE802 11g OFDM with BPSK QPSK 16QAM 64QAM IEEE802 11n BPSK QPSK 16 QAM 64 QAM America FCC 2 412 2 462 GHz 11 channels 5 180 5 240 GHz amp 5 745 5 825 GHz 9 channels Europe CE ETSI 2 412 2 472 Ghz 13 channels 5 180 5 240 GHz 4 channels IEEE802 11b 1 2 5 5 11 Mbps Transmission Rate IEEE802 11a g 6 9 12 18 24 36 48 54 Mbps IEEE801 11n up to 300Mbps 11a 12dBm 1 5dBm 11b 18dBm 1 5dBm 11g 15dBm 1 5dBm Transmit Power 11gn HT20 13dBm 1 5dBm 150Mbps 1ign HT40 12dBm 1 5dBm 300Mbps 11an HT20 12dBm 1 5dBm 150Mbps 11an HT40 12dBm 1 5dBm 300Mbps 11a 68dBm 2dBm 54Mbps 11b
17. status LED 7 Console amp Backup unit port 2 LAN port status LED 8 Ethernet LAN ports 3 Fault status LED 9 DI DO ports 4 WAN status LED 10 Power connector 5 WLAN status LED 11 2 4 5GHz antenna 6 Relay output port 12 Cellular antenna connector 13 SIM card slot 2 1 2 Front Panel LEDs PWR1 Green on ooo DC power 1 activated PWR2 Green C DC power 2 activated Blinking Data transmitted Green On Port is linked ETH2 Blinking Transmitting data Port is linked WLAN is activated WLAN 1 2 Green Blinking Transmitting data WANT 2 Green Modem is connected 2 2 Side Panel Green On On Port is linked ETH1 Green On n n n n Error occurs power fails or port disconnected 1 Antenna connector 2 Reset button WIFI ANT 1 Reset CH ORing Industrial Networking Corp 5 ORing TGAR 1062 2062 1662 Series User Manual Note to restore the device configurations back to the factory defaults press the Reset button for a few seconds Once the power indicator starts to flash release the button The device will then reboot and return to factory defaults 2 2 Top Panel On the top panel sits a SIM card slot and a cellular antenna connector as show as below 19 5 DIE A WIS r LP Ls LNW JEN FAD TGAR 1062 1662 Series l 101S PIED WIS D INY LISImII9 ST TGAR 2062 Series ORing Industrial Networking Corp 6 ORing TGAR 1062 2062 1662 Series User Manual 2 3 Bottom Panel
18. the warning on top of the browser and choose Download File E nout r Click here for x Download File What s the Risk Information Bar Help Indietrial 2909 44 alble 3 Er ORing Industrial Networking Corp 49 ORing TGAR 1062 2062 1662 Series User Manual Click to save existing configurations as a file for future usage Save You can restore configurations to previous status by installing a previous configuration file To do this choose Web Restore or Tftp Restore If you choose Web Restore you need to choose a file and click Web Restore If you selet Tftp Restore fill in a Tftp server IP address and the file name before clicking Tftp Restore Restore Factory Click to reset the router to the factory settings The router will Miscellaneous This page enables you to run ping test which will send out ping packets to test if a computer is on the Internet or if the WAN connection is OK Enter a domain name or IP address in the destination box and click Ping to test Event Warning When an error occurs the router will notify you through system log e mail SNMP and relay ORing Industrial Networking Corp 50 ORing TGAR 1062 2062 1662 Series User Manual System Log m Device Event Notification Hardware Reset Cold Start Software Reset Warm Start Login Failed IP Address Changed Password Changed Redundant Power Changed Eth Link Status Changed SNMP Access Failed Wireless Client Associated Wireless Clie
19. uses TKIP encryption and WPA2 PSK uses AES Encryption Type l l l encryption TKIP AES provides the most reliable security and is easiest to implement Radius Server IP Enter the IP address of the RADIUS server Radius Port Enter the RADIUS port default is 1812 Shared Secret Enter the RADIUS password or key When you set security type as 802 1x the following fields will appear to allow you to configure individual settings WEP Encryption You can select 64 Bit or 128 Bit Available values include ASCII and Hex Key Type ASCII American Standard Code for Information Interchange is a code for Key Type representing English characters as numbers in the range from 0 to 127 Hex digits uses 0 9 to represent values zero to nine and characters A F to represent values ten to fifteen RADIUS Remote Authentication Dial In User Service is a widely deployed protocol that ORing Industrial Networking Corp 28 ORing TGAR 1062 2062 1662 Series User Manual enables companies to authenticate and authorize remote users access to a system or service from a central network server When you configure the remote access server for RADIUS authentication the credentials of the connection request are passed to the RADIUS server for authentication and authorization If the request is both authenticated and authorized the RADIUS server sends an accept message back to the remote access server and the connection attempt is accepted If th
20. DO ORing Industrial Networking Corp 54 ORing TGAR 1062 2062 1662 Series User Manual 5 2 4 System Status System Info This page displays the detailed information of the router including model name description firmware version WAN LAN and wireless settings mo c Model Description Industrial EN50155 IEEE 802 11 a b am 36 Cellular Router with 2x10 100 F nOBase TLX M12 connector WAN Mode Dynamic Setting IP Address 192 168 10 1 Subnet Mask 25009925951 MII 1500 MAC Address UU TE 9400 00 03 DHCP Server Enabled Wireless Wireless Enabled ep aring Channel Auto Encryption Mode None System Log The router will constantly log events and activities and provide the files for you to review You can click Refresh to renew the page or Clear Logs to clear all or certain log entries O DHCP Server Boot Message O NTP Client L PPTP VPN O System Event O UPNP CT Firewall O Modem OpenVpn Desi Log Option DEINEN ONE KR Traffic Statistics This page displays network traffic statistics for packets both received and transmitted through Ethernet ports and wireless connections ORing Industrial Networking Corp 55 ORing TGAR 1062 2062 1662 Series User Manual 1025063 Bytes 1097 Packets 144258 Bytes 1660 Packets 0 Bytes 0 Packets 0 Bytes 0 Packets 0 Bytes 0 Packets 0 Bytes 0 Packets 0 Bytes 0 Packets 0 Bytes 0 Packets Wireless Link List This page displays the Mac address
21. EP WPA WPA PSK TKIP AES WPA2 WPA2 PSK TKIP AES 802 1X authentication B Secure management by HTTPs B Various kinds of WAN connections supported including dynamic static IP PPPoE and modem dial up B Configurable IP tables to prevent unauthorized access B Supports VPN for secure network connection Open VPN PPTP VPN B Supports NAT setting virtual server port trigger DMZ UPnP B Supports DHCP forwarding through PPTP B 3 5G HSDPA modem dial up 3G models B AGLTE modem dial up 4G models B Supports redundant mode Recovery time 10ms and switch mode in M12 connector A coding B Wireless connection status monitoring B Event warning by Syslog e mail SNMP trap and relay output ORing Industrial Networking Corp ORing TGAR 1062 2062 1662 Series User Manual 1 3 Hardware Features 2 x 10 100 1000 Base T X Ethernet ports in M12 connectors 2 X WLAN antenna connectors TGAR 1062 2062 series or 4 x WLAN antenna connectors TGAR 1662 series 1 x cellular antenna connectors TGAR 1062 1662 series or 2 x cellular antenna connectors TGAR 2062 series EN50155 compliance Redundant power inputs 12 48 VDC Casing IP 40 Dimensions 125 6mm W x 65mm D x 196 1mm H 4 94 x 2 55 x 7 72 inch Operating temperature 25 to 70 C Storage temperature 40 to 85 C Operating humidity 596 to 9596 non condensing Wall mounting enabled ORing Industrial Networking Corp 2 ORing TGAR 1062 2062 1662 Series User Manu
22. MTS HSDPA HSUPA H DC HSPA SPA DC HSPA 900 2100 MHz 900 2100 MHz GSM GPRS EDGE GSM GPRS EDGE Band Option 900 1800 1900 MHz 900 1800 1900 MHz Protocol Support gt 0 1 TII LI I I II BI Support Protocol ARP BOOTP DHCP DNS HTTP IP ICMP SNTP TCP UDP RADIUS SNMP PPPoE STP IEEE 802 1D LED indicators Power Indicator 10 100 1000Base T X 2 x LEDs Green for port Link Act Indicator WLAN LED 1 x LED Green for WLAN Link Act WAN LED 1 x LED Green for Cellular modem Link Act 2 x LEDs Green for functioning normal Fault Indicator 1 x LED Red for Ethernet link down or power down indicator Fault contact Relay output to carry capacity of 3A at 24VDC Relay output to carry capacity of 1A at 24VDC Power Redundant Input Power Dual Power Inputs 12 48 VDC on M23 connector 24 VDC Typ Power Consumption Typ 9 Watts 9 5 Watts 13 Watts 15 Watts 2 x LEDs Green for Power on Overload Current Protection Present Physical Characteristic Dimension W x D x H 125 6 W x 65 D x 196 1 H mm 4 94 x 2 55 x 7 72 inch Weight g 985g 968g 1030g 1030g Environmental Storage Temperature 40 to 85 C 40 to 185 F Operating Temperature 25 to 70 C 13 to 158 F Operating Humidity 5 to 95 Non condensing Regulatory approvals oo FCC Part 15 CISPR EN55022 class A EN50155 EN50121 3 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000
23. RF cables and antennas can also be used with the connector 3G Cellular Antenna 4G LTE Antenna ORing Industrial Networking Corp 15 ORing TGAR 1062 2062 1662 Series User Manual Management 5 1 Network Connection Before installing the router you need to be able to access the router via a computer equipped with an Ethernet card or wireless LAN interface To simplify the connection it is recommended to use an Ethernet card to connect to a LAN PC2 PC 3 Network Connection of the Router Before installing the router you need a computer equipped with an Ethernet card or wireless LAN interface To simplify the connection it is recommended to use an Ethernet card to connect to a LAN Follow the steps below to install and connect the router to PCs Step 1 Select a power source The router can be powered by 12 48V DC power input or via a PoE Power over Ethernet PSE Ethernet switch Step 2 Connect a computer to the router Use either a straight through Ethernet cable or cross over cable to connect the ETH1 port of the router to a computer Once the LED of the LAN port lights up which indicates the connection is established the computer will initiate a DHCP request to retrieve an IP address from the AP router Step 3 Configure the router on a web based management utility Open a web browser on your computer and type http 192 168 10 1 default gateway IP of the router in the address box to access the webpage
24. T Setting DMZ DMZ Demilitarized Zone allows a computer to be exposed to the Internet without passing through the security settings and therefore is unsecured This feature is useful for special purposes such as gaming To use this function you need to set an internal computer as the DMZ host by entering its IP address Adding a client to the DMZ may expose your local network to a variety of security risks so use this function carefully EE ordisablos NZ DMZ Host IP Ener th 1P ade ofthe computer to at as the DMZ host NAT Setting UPnP The UPnP Universal Plug and Play feature allows Internet devices to access local host resources or devices as needed UPnP enabled devices can be automatically discovered by the UPnP service application on the LAN C Application Ext Port Int Port IP Address ORing Industrial Networking Corp 35 ORing TGAR 1062 2062 1662 Series User Manual up Enable or disable UPnP Enable NAT PMP NAT PMP allows a computer in a private network behind a NAT router to automatically configure the router to allow parties outside the private network to contact with each other NAT PMP operates with UDP It essentially automates the process of port forwarding Check the box to enable NAT PMP UPnP List This table lists the current auto port forwarding information Application The application that generates this port forwarding Ext Port The port opened on WAN Protocol The proto
25. al Hardware Overview 2 1 Front Panel 2 1 1 Ports and Connectors The series is equipped with the following ports and features on the front panel 10 100 1000 Base T X Ethernet ports 2 x 10 100 1000 Base T X ports supporting with M12 connectors D coding auto negotiation Relay output with M12 A coding 1 x relay output to carry capacity of 1A at 24VDC connector M23 power connector with redundant l Dual power inputs for 12 48 VDC power inputs DIDO with M12 connector D coding 4 x digital input 4 x digital output 12 13 E 1 J ES VE Wi me UP cl Transporter d dp T 1 1 EME 155 TAR OG 23 Col 2 E FAR AM Relay Output ETH D CL WAS AE gRREREE Fe TGAR 1062 Series ORing Industrial Networking Corp 3 ORing TGAR 1062 2062 1662 Series User Manual zO Z enge af 6 Relay Output 4 1 7 eS evo Console O98 222 11299994 A e oO Ka D Q ys C DO D ETH2 ETH1 ae cow De oo Dee fei Za A pus Y SRERERER To TGAR 2062 Series ORing z Transporter outers TGAR 1662 3G M12 Vi c Relay Output ow Console a Z ETH Fault vo T san on el por 003 o cu Do DI ETH2 ETH1 S S DOs 201 Ds o0 H p EN f 4 4 f 5 NV 15i DC 29 00 38 00 D O 98 TGAR 1662 Series ORing Industrial Networking Corp 4 ORing TGAR 1062 2062 1662 Series User Manual 1 Power
26. col type Int Port The port redirected to the local computer IP Address The IP address of local computer to be redirected to Firewall Setting IP Filter IP filters enable you to control the forwarding of incoming and outgoing data between your LAN and the Internet and within your LAN This control is implemented via IP filter rules which are defined to block attempts by certain computers on your LAN to access certain types of data or Internet locations You can also block incoming access to computers on your LAN ORing Industrial Networking Corp 36 ORing TGAR 1062 2062 1662 Series User Manual IP Filter Enables or disables the IP Filter Enter description for the entry Configures the rules to be applied to the IP filter Available options include DROP ACCEPT and REJECT UEM udin Shows the information of all IP filters Click Edit to edit the entry or Del to delete the entry Firewall Setting MAC Filter This page enables you to deny or allow LAN computers to access the Internet based on their MAC addresses LEN TT XN Rue MAC Address enabled Configures the rules to be applied to the MAC filter Available EM ee meme Shows the information of all MAC filters Click Edit to edit the entry or Del to delete the entry ORing Industrial Networking Corp 37 ORing TGAR 1062 2062 1662 Series User Manual Vpn Setting Open Vpn A VPN is a method of linking two locations as if they are on a local pri
27. d new entries to the static routing tablet Choose Gateway Mode if you want PCs in the LAN to visit external network otherwise choose Router Mode Choose Disable to disable dynamic routing or other options to configure the interfaces for dynamic routing This option is only available when dynamic routing is enabled It allows you to make detailed configurations via simple comments cU Telnet 192 168 10 1 Command incomplete ello this is zebra version KE K copyright 1996 2082 Kunihiro Ishiguro APR6549 78 gt enable Turn on privileged mode command exit Exit current mode and down to previous list Print command list ping send echo messages quit Exit current mode and down to previous mode show Show running system information telnet Open a telnet connection traceroute Trace route to destination Switch Se Ec XE Switch Switch Routing Topography ORing Industrial Networking Corp 47 ORing TGAR 1062 2062 1662 Series User Manual 5 2 3 System Tools Login Setting You can change login name and password in page The default login name and password are both admin Old Name Type in current login name Old Password Type in current password Enter a new login name Acceptable characters contain 0 9 a Z A Z and the length must be 1 to 15 characters An empty name is not acceptable New Password Enter a new login password Acceptable characters contain m 0 9 az A Z and the length
28. dustry Canada Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Industry Canada Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of Industry Canada Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat rial brouilleur Appareils Num riques NMB 003 dict e par l Industrie ORing Industrial Networking Corp 62 ORing TGAR 1062 2062 1662 Series User Manual Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cau
29. e request is either not authenticated or not authorized the RADIUS server sends a reject message back to the remote access server and the connection attempt is rejected The principle of the Radius server is shown in the following pictures Users Database c Wireless Computer Mali RADIUS Server e through Cert CN EE Wired Computer Wireless Router Client Mode In this mode the router functions as a wireless client to connect your wired devices to a wireless network This mode provides no access point services but supports 802 1 X Hidden Show SiteTable ORing Industrial Networking Corp 29 ORing TGAR 1062 2062 1662 Series User Manual Peer AP SSID Enter the SSID of the AP you want to connect as a client Peer AP BSSID Enter the BSSID Wireless MAC address to limit client target Site Survey You can scan APs on the network using this mode Slave Mode Enables or disables slave mode Security Type Select the security type used by the client you want to connect DDNS DDNS Dynamic Domain Name System allows you to configure a domain name for your IP address which is dynamically assigned by your ISP Therefore you can use a static domain name that always points to the current dynamic IP address UserName Enter tre username of your DDNS accout Domain Enter tre domain name provided by your dynam DNS seca provider Date amp Time In this page you can set the date amp time of the
30. e access point The message is generated within the periodic beacon at a frequency specified by the DTIM Interval When the AP sends a DTIM with a DTIM interval value the client hearing the beacons will awake to receive the messages The default value is 1 and the value must be between 1 and 255 milliseconds Fragmentation The value specifies the maximum size for a packet before data is Threshold fragmented into multiple packets The value should remain at the default 2346 the range is 256 2346 bytes If you experience a high packet error rate you may slightly increase the value Setting the value too low may result in poor network performance Only minor modifications of this value are recommended RTS Threshold The RTS Request to Send Threshold is the amount of time a wireless device attempting to send will wait for a recipient to acknowledge that it is ready Normally the AP sends a RTS frame to a station and negotiates the sending of data After receiving the RTS the station responds with a CTS Clear to Send frame to acknowledge the right to begin transmission To ensure communication the maximum value should be used which is the default value 2347 the range is 0 2347 bytes If a network packet is smaller than the preset RTS threshold size the RTS CTS mechanism will not be enabled Wireless Mode You can select 802 11 b b g or b g n mode Preamble Available values include Long and Short with Long as the default
31. e wire conduit To avoid interference wires with different signal characteristics should be routed separately 6 You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring sharing similar electrical characteristics can be bundled together 7 You should separate input wiring from output wiring 8 Itis advised to label the wiring to all devices in the system ORing Industrial Networking Corp 12 ORing TGAR 1062 2062 1662 Series User Manual Cables and Antenna 4 1 Ethernet Pin Definition The routers have two 10 100 1000 Base T X Ethernet ports According to the link type the AP uses CAT 3 4 5 5e UTP cables to connect to any other network device PCs servers switches routers or hubs Please refer to the following table for cable specifications 10Base T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ45 100Base T X Cat 5 100 ohm UTP UTP 100 m 328 ft RJ45 1000Base T X UTP 100 m 328 ft RJ45 RSVD ORing Industrial Networking Corp 13 ORing TGAR 1062 2062 1662 Series User Manual 4 3 DI DO 4 4 Wireless Antenna The series uses 2 4GHz 5GHz antennas with reversed SMA connectors You can also use external RF cables and antennas with the connectors ORing Industrial Networking Corp 14 ORing TGAR 1062 2062 1662 Series User Manual 4 5 Cellular Antenna The series are packed with one or two 3G and 4G antennas External
32. et IP Address Subnet Mask and Default Gateway according to IP rules Obtain DNS server Obtains a DNS server address from a DHCP server If you have ORing Industrial Networking Corp 21 ORing TGAR 1062 2062 1662 Series User Manual address chosen to obtain an IP address automatically this option will be automatically selected accordingly Use the following opecifies a DNS server address manually You can enter two DNS server addresses as the primary and secondary options addresses Peer AP SSID Enter the SSID of the AP you want to connect as a client Site Survey Click the button to browse available sites if you do not know the SSID A list of available sites will be displayed Security Type Select the security type used by the client you want to connect Use Modem 3G as Enable this option if you want to use modem 3G as a backup backup connection connection when main connection is lost Enter your account username and password in the corresponding fields Type a website address such as www google com in Ping Test Site to use it to check if the connection is alive or lost LAN This page allows you to configure the IP settings of the LAN for the router The LAN IP address is private to your internal network and is not visible to Internet TRE 192 168 10 1 255 255 255 0 o Subnet mask Tne subnet mask ofthe LAN The dau value 152852852580 LLDP Protocol LLDP is a vendor neutral protocol used by netw
33. he grounding surface prior to connecting devices 3 2 2 Fault Relay The router uses a M12 A coded 5 pin male connector on the front panel for relay output Use a power cord with an M12 A coded 5 pin female connector to connect the relay The relay contacts will detect user configured events and form an open circuit when an event is triggered ORing Industrial Networking Corp 11 ORing TGAR 1062 2062 1662 Series User Manual Relay w 1A 24VDC 3 2 3 Redundant Power Inputs The device supports two sets of power supplies and uses the M23 5 pin female connector on the front panel for the dual power inputs Step 1 Insert a power cable to the power connector on the device Step 2 Rotate the outer ring of the cable connector until a snug fit is achieved Make sure the connection is tight ATTENTION 1 Be sure to disconnect the power cord before installing and or wiring your routers 2 Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size 3 If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment 4 Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point 5 Do not run signal or communications wiring and power wiring through the sam
34. ients Shows the wireless MAC addresses associated with the router MAC Filter Table You can edit up to MAC addresses in these fields Apply Click to activate the configurations NAT Setting Virtual Server This page allows you to set up virtual server setting A virtual server allows Internet users to access services on your LAN This is a useful function if you host services online such as FTP Web or game servers A public port must be defined for the virtual server on your router in order to redirect traffic to an internal LAN IP address and LAN port Any PC used as a virtual server must have a static or reserved IP address eee Public Local Virtual Server select Enabled or Disabled to activate or deactivate virtual nnlli m Description Enter the description of the entry Acceptable characters are 0 9 eege Enter a public IP allowed to access the virtual service If not specified choose All Public Port The port number to be used to access the virtual service on the ORing Industrial Networking Corp 34 ORing TGAR 1062 2062 1662 Series User Manual WAN Wide Area Network The protocol used for the virtual service Local IP The IP address of the computer that will provide virtual service Local Port The port number of the service used by the private IP computer Enable Now Enables the virtual server entry after adding it Virtual server list Click Edit to edit the virtual service entry and Del to delete the entry NA
35. must be 0 to 15 characters Web Protocol Choose a web management page protocol from HTTP and HTTPS HTTPS HTTP over SSL encrypts data sent and received over the Web Choose HTTPS if you want a secure connection Choose a web management page port number For HTTP default port is 80 For HTTPS default port is 443 Router Restart This page allows you to configure restart settings for the router ORing Industrial Networking Corp 48 ORing TGAR 1062 2062 1662 Series User Manual Restart Now Click to restart the router via warm reset Enable check to activate the setting Restart at specify the time for resetting the router You can configure the action to be performed periodically Firmware Upgrade ORing launches new firmware constantly to enhance router performance and functions To upgrade firmware download new firmware from ORing s website to your PC and install it via Web upgrade Make sure the firmware file matches the model of your router It will take several minutes to upload and update the firmware After upgrade completes successfully reboot the router E During firmware upgrading do not turn off the power of the router or press the reset button Save Restore Configurations This page allows you to save configurations or return settings to previous status You can download the configuration file from the Web Note users using old versions of Internet Explorer may have to click on
36. nformation please visit openvpn website Vpn Setting PPTP VPN PPTP Point to Point Tunneling Protocol VPN allows PCs connected to the router through WAN ports to act as PCs in the same LAN ORing Industrial Networking Corp 40 ORing TGAR 1062 2062 1662 Series User Manual WAN Link PPTP VPN m Offic PC To create a PPTP connection to the router you must create a new network connection on your Windows PC by right clicking Network gt Property gt Create a new connection gt Connect to my work space VPN Use VPN to Internet and then enter the user name and password set in the page After setting up a new connection you can make configurations in the following page Label PPTP Server Enables or disables PPTP VPN server Enter the server IP address The default value is the IP address of the connected LAN port ORing Industrial Networking Corp 41 ORing TGAR 1062 2062 1662 Series User Manual Client IP Enter the IP address range in the form of 192 168 10 xx xx The connected client will be assigned with an IP address CHAP Secrets Enter the username and password pairs in the form of user pass Multiple username and password pairs are allowed Vpn Setting PPTP Client If a router wants to link to the routers in different networks you should enable PPTP client in the following page WAN Line WAN Line PPTP VPN Line of PPTP VPN LAN Line
37. nt Disassociated Client Mode Associated Client Mode Disassociated Client Mode Roaming Fault Event Notification Power 1 Fault Power 2 Fault Eth Link Down DIL ON gt OFF DI ON gt OFF DI3 ON gt OFF DI4 ON gt OFF DIL OFF OfN DI OFF gt ON DIS OFF gt ON DI4 OFF ON Syslog Server IP Enter the IP address of a remote server if you want the logs to be stored remotely Leave it blank will disable remote syslog Syslog Server Port Specifies the port to be logged remotely Default port is 514 ORing Industrial Networking Corp 51 ORing TGAR 1062 2062 1662 Series User Manual E mail Device Event Notification Hardware Reset Cold Start Software Reset Warm Start Login Failed IP Address Changed Password Changed Redundant Power Changed Eth Link Status Changed SNMP Access Failed Wireless Client Associated Wireless Client Disassociated Client Mode Associated Client Mode Disassociated Client Mode Roaming Fault Event Notification Power 1 Fault Power 2 Fault Eth Link Down DI1 ON OFF DI2 ON OFF DI3 ON OFF DI4 ON gt OFF DIL OFF DI OFF DIS OFF DI4 OFF gt SMTP Server Enter a backup host to be used when the primary host is unavailable Server Port opecifies the port where MTA can be contacted via SMTP server E mail Address 1 4 Enter the mail address that will receive notifications ORing Industrial Networking Corp 52 ORing TGAR 1062 2062 1662 Series User Manual
38. oad Current Protection Present Physical Characteristic Environmental 5 to 95 Non condensing Regulatory approvals EMI FCC Part 15 CISPR EN55022 class A EN50155 EN50121 3 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS EMS EN61000 4 8 EN61000 4 11 ORing Industrial Networking Corp 60 ORing TGAR 1062 2062 1662 Series User Manual Dry Heat EN60068 2 2 Safety EN60950 1 Warranty Eyer OSSUUuQ Uui ORing Industrial Networking Corp 61 ORing TGAR 1062 2062 1662 Series User Manual Compliance FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation HF exposure warning The equipment complies with RF exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device should be operated with minimum distance 20cm between the device and all persons Operations in the 5 15 5 25GHz band are restricted to indoor usage only In
39. ol for WLAN WEP will encrypt data transmitted on the WLAN ORing Industrial Networking Corp 25 ORing TGAR 1062 2062 1662 Series User Manual WPA WPA2 Personal uses a pre shared key for authentication This pre shared key is then dynamically sent between the AP and clients Each authorized computer is given the same pass phrase WPA WPA2 Enterprise this type includes all of the features of WPA WPA2 Personal plus support for 802 1x RADIUS authentication 802 1x authentication through a RADIUS server When you set security type as WEP the following fields will appear to allow you to configure individual settings Available values include Open Shared and WEPAUTO When choosing Open or Shared all of the clients must select the Auth Mode same authentication to associate this AP If select WEPAUTO the clients do not have to use the same Open or Shared authentication They can choose any one to authenticate Available values include ASCII and Hex Key Type ASCII American Standard Code for Information Interchange is a code for representing English characters as numbers in the Key Type range from O to 127 Hex digits uses 0 9 to represent values zero to nine and characters A F to represent values ten to fifteen Default Key Index Select one of the keys to be the active key Key 1 to 4 You can input up to four encryption keys ORing Industrial Networking Corp 26 ORing TGAR 1062 2062 1662 Series User Man
40. ork devices for advertising their identity capabilities and neighbors on a LAN You can enable or disable LLDP protocol DHCP DHCP is a network protocol designed to allow devices connected to a network to communicate with each other using an IP address The connection works in a ORing Industrial Networking Corp 22 ORing TGAR 1062 2062 1662 Series User Manual client server model in which DHCP clients request an IP address from a DHCP server The router comes with a built in DHCP Dynamic Host Control Protocol server which assigns an IP address to a computer DHCP client on the LAN automatically The router can also serve as a relay agent which will forward DHCP requests from DHCP clients to a DHCP server on the Internet The IP allocation provides one to one mapping of MAC address to IP address When a computer with a MAC address requesting an IP address from the router it will be assigned with the IP address according to the mapping You can choose one from the client list and add it to the mapping list Built in DHCP Server v o 192 168 102 1921681010 fe storing Endino IP Subnet Mosk Operations Ges c MAC Address IP address DHCP Mode Available options include Built in DHCP Server and DHCP Forwarder Built in DHCP Server will enable the router to automatically assign an IP add
41. ress to a computer on the LAN ORing Industrial Networking Corp 23 ORing TGAR 1062 2062 1662 Series User Manual DHCP Forwarder will forward DHCP messages to a server on the Internet to handle DHCP requests If you choose DHCP Forwarder enter a DHCP server IP address DHCP Server Enables or disables the DHCP server function The default T ieee a eS The starting IP address of the IP range assigned by the DHCP mdi bl The ending IP address of the IP range assigned by the DHCP Lease Time The period of time for the IP address to be leased During the lease time the DHCP server cannot assign that IP address to any other clients Enter a number in the field The default setting is 48 hours Sang The staring 1P or the DHCP rey ane Ending IP Te ending Piorthe DHCP voy range Subnet ask Enter a Subnet mask tor the DHCP reay rane List of DHCP Range Shows all IP addresses for the DHCP relay range for Relay Allocate IP Address By selecting an IP address from the drop down list and click Manually Copy to you can edit the MAC addresses and IP addresses already assigned by the router and add it to Static DHCP Client List MAC Address The MAC addresses of the computer IP Address The IP address to be related to the MAC address Static DHCP Client List Shows the IP addresses locked to specific MAC addresses is Wireless AP You can set the device to work in AP mode This is the most common mode for all wireless APs
42. roduct s associated with this publication DISCLAIMER Information in this publication is intended to be accurate ORing shall not be responsible for its use or infringements on third parties as a result of its use There may occasionally be unintentional errors on this publication ORing reserves the right to revise the contents of this publication without notice CONTACT INFORMATION ORing Industrial Networking Corp 3F No 542 2 JnongJheng Rd Sindian District New Taipei City 23148 Taiwan R O C Tel 886 2 2218 1066 Fax 886 2 2218 1014 Website www oring networking com Technical Support E mail support oring networking com Sales Contact E mail sales oring networking com Headquarters sales oring networking com cn China ORing Industrial Networking Corp 1 ORing TGAR 1062 2062 1662 Series User Manual Tables of Content Getting E aC hs cers ieee 1 1 1 About TGAR 1062 2062 1662 Series iii seen 1 1 2 SON E eo 1 1 3 AOW FEAE a 2 2 1 FT AU aO Om 3 214 1 POMS AiG COR S eserse ri AA EASA AA 3 2d FORNI hl RE 5 2 2 EE E et 5 2 2 WO Te ANG hate r UT 6 2 3 POLOM Ie Al ERP E CIBO LUAM TU mEV DEFUI MEI DUL I ODE UNI E CMM 7 Hardware Installation KEEN RER ENKE cernere nennen nnne nnn nnn 8 3 1 Wall Mounting Installation annannannnnennannennnnennnnnnnnnnrnnnnsnrnrnrrsnrsrrnrenrsrrsrrnrerrsrrsreenne 8 3 2 Ce Lee YY
43. s Disabled the router will operate in static routing mode which means routers forward packets using either route information from route table entries that you manually configure or the route information that is calculated using dynamic routing algorithms ORing Industrial Networking Corp 45 ORing TGAR 1062 2062 1662 Series User Manual 192 168 10 0 0 0 0 0 299 209 2090 0 br AN 127 0 0 0 0 0 0 0 299 0 0 0 LU lof LOOPBACK 192 168 11 0 0 0 0 0 255 255 255 0 1 WAN E gg Gateway v Dynamic Routing Dynamic routing lets routing tables in routers change as the routes change If the best path to a destination cannot be used dynamic routing protocols change routing tables when necessary to keep your network traffic moving Dynamic routing protocols include RIP OSPF and BGP however the IGAR 2062 only supports RIP Routing Information Protocol Do not choose Disable in the RIPv1 amp v2 list if you want to enable Dynamic Routing After clicking Apply more information will be displayed in Current Routing Table 192 168 10 0 0 0 0 0 09 299 299 J brOtL AN 127 0 0 0 0 0 0 0 299 0 0 0 J Io LOOPBACK E I Gas ORing Industrial Networking Corp 46 ORing TGAR 1062 2062 1662 Series User Manual Current Routing Table Static Route Entry RIPv1 amp v2 Telnet Setting Shows all routing information including static and dynamic routing if enabled Fills in corresponding information to ad
44. s primary routing and the backup routers monitor the status of the master router and become active if the master router fails ORing Industrial Networking Corp 43 ORing TGAR 1062 2062 1662 Series User Manual Virtual Router Virtual Router ID A VRID consists of one master router and one or more backup routers The master router is the router that owns the IP address you associate with the VRID Configure the VRID on the router that owns the default gateway interface The other router in the VRID does not own the IP address associated with VRID but provides the backup path if the Master router becomes unavailable Virtual Router IP An IP address associated with the VRID from which other hosts can obtain network service The VRIP is managed by the VRRP instances belonging to a VRID ORing Industrial Networking Corp 44 ORing TGAR 1062 2062 1662 Series User Manual Greg The priority value used by the VRRP router when selecting the inne virtual router ae Password Enter the Enter the password for authentication for authentication Routing Protocol Routing Setting This page shows the information of the routing table You can configure static and dynamic routing settings in this page 192 168 10 0 0 0 0 0 299 200 290 U J brOtL AN 127 0 0 0 0 0 0 0 255 0 0 0 J Io LOOPBACK Gas 192 168 10 0 0 0 0 0 Zan I ol LU brOtL AN 127 0 0 0 0 0 0 0 299 0 0 0 LU lof LOOPBACK Static Routing When RIPv1 amp v2 i
45. s up Connection Mode mE Connect on Demand disconnect the PPP session if the router ORing Industrial Networking Corp 19 ORing TGAR 1062 2062 1662 Series User Manual has had no traffic for a specified amount of time Fill a number in the Max Idle Time field Manual connects or disconnects manually via the Connect Disconnect buttons at the end of the page Enable this option if you want to use modem 3G as a backup connection when main connection is lost Use Modem 3G as Enter your account username and password in the corresponding backup connection fields Type a website address such as www google com in Ping Test Site to use it to check if the connection is alive or lost WAN Connection Type as Modem 3G 4G Um EertheAPNvaueootora O O UserName EnertheusernameprovdeatyyourlSP Pn Emera PIN coge f you want petom PIN chek um Ste Stonsihe sus ot Sea OoOO ORing Industrial Networking Corp 20 ORing TGAR 1062 2062 1662 Series User Manual Shows the status of connections Shows information about the modem WAN Connection Type as Wireless Client Wireless Client M HiddenfShov Deck abl Description oo0 Obtain an IP address Select this option if you want the IP address of the WAN port to be assigned automatically by the DHCP server in your network automatically Use the following IP Select this option if you want to assign an IP address to the WAN address port manually You should s
46. se undesired operation of the device L op ration est soumise aux deux conditions suivantes 1 cet appareil ne peut causer d interf rences et 2 cet appareil doit accepter toute interference y compris celles susceptibles de provoquer fonctionnement du dispositit To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication Afin de r duire les interf rences radio potentielles pour les autres utilisateurs le type d antenne et son gain doivent tre choisie que la puissance isotrope rayonn e quivalente PIRE est pas plus que celle premise pour une communication r ussie RF exposure warning The equipment complies with RF exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter Avertissement d exposition RF L quipement est conforme aux limites d exposition aux RF tablies pour un incontr l s environnement L antenne s utilis e pour ce transmetteur ne doit pas tre co localis s ou fonctionner en conjonction avec toute autre antenne ou transmetteur ORing Industrial Networking Corp 63
47. ual When you set security type as WPA WPA2 Personal the following fields will appear to allow you to configure individual settings WPA WPA2 Personal ha Available values include WPAPSK WPA2PSK and WPAPSK WPA2PSK mix WPAPSK and WPA2PSK will encrypt the link without additional RADIUS server only an Auth Mode access point and client station that supports WPA PSK is required For WPA WPA2 authentication is achieved via WPA RADIUS Server You need a RADIUS or other authentication server on the network Available values include TKIP AES and TKIP AES mix WPA PSK uses TKIP encryption and WPA2 PSK uses AES Encryption Type encryption TKIP AES provides the most reliable security and is easiest to implement When you set security type as WPA WPA2 Enterprise the following screen will appear to allow you to configure individual settings WPA WPA2 Enterprise M radius key abl Description Available values include WPAPSK WPA2PSK and WPAPSK WPA2PSK mix WPAPSK and WPA2PSK will encrypt the link without additional RADIUS server only an Auth Mode access point and client station that supports WPA PSK is ORing Industrial Networking Corp 27 ORing TGAR 1062 2062 1662 Series User Manual required For WPA WPA2 authentication is achieved via WPA RADIUS Server You need a RADIUS or other authentication server on the network Available values include TKIP AES and TKIP AES mix WPA PSK
48. value If all clients and access points in your wireless network support short preamble then enabling it can boost overall throughput However if any wireless device does not support short preamble then it will not be able to communicate with your network If you are not sure whether your radio supports the short RF preamble you must disable this feature ORing Industrial Networking Corp S 83 Industrial Networking Corp 32 ORing TGAR 1062 2062 1662 Series User Manual o a E Roaming Select Disabled to disable X Roaming protocol or select ME X roaming to enable X Roaming protocol Scan Channel Select All to scan all supported channels or Manual to scan only Ell rM Sensitivity Configures signal sensitivity Scan interval Configures scan interval Wireless Setting MAC Filter This page allows you to set up MAC filters to allow or deny wireless clients to connect to the router You can manually add a MAC address or select a MAC address from the Associated Clients list currently associated with the router Choose an Associated Client Chocseaslot w ORing Industrial Networking Corp 33 ORing TGAR 1062 2062 1662 Series User Manual MAC Filter Select Enabled or Disabled to activate or deactivate MAC filters Select one of the options to allow or deny the MAC address in the list Associated Cl
49. vate network to facilitate data transmission and ensure data security The links between the locations are known as tunnels VPN can achieve confidentiality authentication and integrity of data by utilizing encapsulation protocols encryption algorithms and hashing algorithms Open VPN enables you to easily set up a virtual private network over an encrypted connection It is a full function SSL VPN solution which accommodates a wide range of configurations including remote access site to site VPNs WiFi security and enterprise level remote access with load balancing failover and fine grained access control features To set up your router as an Open VPN server you need to install openvpn client software for your Windows based PC You can download it from http openvpn net download himl stablel The software version must match the current version of Openvpn used by IGAR 2062 3G 4G which is version 2 0 9 WAN Link WAN Link OPEN Sever VPN Link ma Home PC T d gt Offic PC LAN Link Connection to Open VPN Server When you enable Open VPN Client you need two routers to create site to site VPN connections The server IP and client IP address should be within the same network domain ORing Industrial Networking Corp 38 ORing TGAR 1062 2062 1662 Series User Manual WAN Link WAN Link OPEN VPN Client OPEN VPN Sever LAN Link LAN Link LAN Link Client PC g Server PC WAN PC
Download Pdf Manuals
Related Search
Related Contents
"取扱説明書" HP PhotoSmart R727 User's Manual Graco 308167L User's Manual Black & Decker CHV1600 Instruction Manual IRIX™ Device Driver Programmer`s Guide 取扱説明書 Manual de instrucciones bilingüe (Español e Inglés) Sweex Internal Multi Card Reader USB (公募要領) [PDF 266 KB] Copyright © All rights reserved.
Failed to retrieve file