1. 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 5 Mating Connections Wiring The IP67 Industrial Switches meet or exceed all MIL STD 38999 Series Ill for severe environmental applications All connectors and their mating couplings have EMI shielding and ESD moisture and corrosion resistance All mating connectors will self lock with one 360 degree turn of the coupling nut Overview The following mating plugs are required to interface with the switch Mating Connections Ethernet Plug D38999 26WA35PN w pin contacts and Normal keying Power Plug D38999 26WA98SA w socket contacts and A keying USB RS232 Plug D38999 26WA35PA w pin contacts and A keying Typical Plug Cable The maximum cable length for 10 100BaseT is typically 100 meters 328 ft Distance ET 8xS MIL_manual r05 Page 8 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 6 Service Information Product Support ET 8xS MIL_manual r05 Service Information We sincerely hope that you never experience a problem with any Sixnet product If you do need service call Sixnet at 518 877 5173 and ask for Technical Support A trained specialist will help you to quickly determine the source of the problem Many problems are easily resolved with a single phone call If it is ne
2. e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 2 LED Indicators Overview The IP67 Industrial Ethernet switches have communication LEDs for each port an OK output LED a status LED and power LEDs Refer to the sample pictures below for the location of these LEDs x eo 3 ge r j LED Locations Status LED The Status LED indicates the overall health of the switch It is normally ON solid indicating that no internal CPU or software problems are detected It will flash when loading firmware and briefly on power up or reset Otherwise if it is OFF or flashing for an extended period of time then a problem is detected In this case please contact your switch supplier for support Power LEDs Hi a power LED labeled as Power It will be on solid when power is applied to the LNK LED The port LEDs are multifunctional and indicate link confirmation activity and speed Flashing Indicates that there is a proper Ethernet connection Link between the port and another Ethernet device and that there is communications activity On Solid Indicates that there is a proper Ethernet connection Link between the port and another Ethernet device but no communications activity is detected Off Indicates that there is not a proper Ethernet connection Link between the port and another Ethernet device Make sure the cable has been plugged securely into the ports at both ends 100 LE
3. service meets your needs If you have any suggestions to help us improve our service please give us a call We appreciate your ideas and will respond to them For Your Convenience Please fill in the following and keep this manual with your Sixnet system for future reference Serial Date Purchased Purchased From To obtain support for Sixnet products Latest product info htip www sixnet com Phone 1 518 877 5173 Fax 1 518 877 8346 E mail support sixnet com Mailing address Sixnet 331 Ushers Road Ballston Lake NY 12019 Page 9 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com
4. 22 2 213 Division 2 Zone 2 ATEX IEC60079 0 15 Page 3 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Military Standards Compliance Safety Warnings A A WARNING EXPLOSION HAZARD WARNING EXPLOSION HAZARD WARNING EXPLOSION HAZARD ET 8xS MIL_manual r05 Package protection IP67 dust oil and water tight Dimensions LxWxH 10 5 x4 x 1 5 see diagram on next page 267 x 102 x38 mm Weight including caps 2 20 lbs 1 Kg MIL Standard Specification MIL STD 810F 501 4 70 C Transport Storage High Temperature 501 4 Il 65 C operating MIL STD 810F 502 4 I Low Temperature 501 4 I Vibration MIL STD 1275B 100V for 1 second Surge Protection 15 000 watts peak Transient Voltage I 250V 50 times for 100uS Spike Protection Strictly abiding by these warnings will help ensure the safe installation startup and operation of the switch INSTALL THE SWITCH IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES LIGHTNING DANGER DO NOT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING ACTIVITY SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 ZONE 2 WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS Page 4 of 9 Last Revised 29 Apr 13 Sixnet
5. D The port LEDs are multifunctional and indicate link confirmation activity and speed ON A 100 Mbps 100BaseT connection is detected OFF A 10 Mbps 10BaseT connection is detected OK LED This LED is not used in the standard model and will always be off On special order units with dual power inputs the OK LED will be lit when both the P1 and P2 pins have power applied ET 8xS MIL_manual r05 Page 5 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY12019 e USA e 1 518 877 5173 e support sixnet com Section 3 Mechanical Dimensions and Installation The IP67 Industrial Ethernet Switch can be mounted either on its edge or flat as shown below All LED s are visible from either mounting position Overview NOTE Mounting holes will accept a 12 size screw or smaller 2 45 62 2mm p 2 24 56 9mm _ Dia 0 200 5 1 diin 1 50 38 1mm y 4 ___ 2 98 75 7mm 0 75 19 1mm __ __ 2 68 68 1mm 0 35 8 9mm 1 30 33 0mm N EN g N a gt e with no cap or _ plug installed O G 5 with cap installed 0 RS232 USB tether not shown Port O H typica
6. Si XI et USER MANUAL ared Hon busines IP67 Fast Ethernet Industrial Switch P67 Ethernet zN Switch S N Installation and Wiring Manual Contents at a Glance Section 1 _ General Specifications LED Indicators Page 5 Sections Mechanical Dimensions Installation Power and Communication Wiring Page 7 Mating Connections Wiring Page 8 Service Information Page 9 This manual applies to the following products e ET 8ES MIL 1 8 port unmanaged IP67 Ethernet switch with 8 10 100 ports e ET 8MS MIL 1 8 port managed IP67 Ethernet switch with 8 10 100 ports ET 8xS MIL_manual r05 Page 1 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com SIXNET Protected Technology Policy Sixnet protects your investment in Sixnet systems with long term planned technology and our unique Protected Technology Policy We will continue to support the specified capabilities of standard Sixnet products for at least five years twenty years for Industrial Managed Switches We plan each product improvement and new feature to be upward compatible with existing designs and installations Our goals are to make each new software release bring new power to your Sixnet systems and have every existing feature applications program and data file continue to work We protect your investment even further with a liberal five year trade in policy Exchange standard products f
7. cessary to return a unit to us an RMA Return Material Authorization number will be given to you Sixnet tracks the flow of returned material with our RMA system to ensure speedy service You must include this RMA number on the outside of the box so that your return can be processed immediately The applications engineer you are speaking with will fill out an RMA request for you If the unit has a serial number we will not need detailed financial information Otherwise be sure to have your original purchase order number and date purchased available We suggest that you give us a repair purchase order number in case the repair is not covered under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RMA form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Normally repairs are completed in two days Sometimes difficult problems take a little longer to solve If you need a quicker turnaround ship the unit to us by air freight We give priority service to equipment that arrives by overnight delivery Many repairs received by mid morning typical overnight delivery can be finished the same day and returned immediately We apologize for any inconvenience that the need for repair may cause you We hope that our rapid
8. entative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied Sixnet s liability shall not exceed the price of the individual units which are the basis of the claim In no event shall Sixnet be liable for any loss of profits loss of use of facilities or equipment or other indirect incidental or consequential damages INSTALLATION AND HAZARDOUS AREA WARNINGS These products should not be used to replace proper safety interlocking No software based device or any other solid state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Sixnet disclaims any responsibility for damages either direct or consequential that result from the use of this equipment in any application All power input and output I O wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful
9. interference to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Copyright amp Trademarks Copyright 2010 Sixnet All Rights Reserved Note All information in this document is subject to change without notice ET 8xS MIL_manual r05 Page 2 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY12019 e USA e 1 518 877 5173 e support sixnet com Section 1 Overview Operation Standards and Specs ET 8xS MIL_manual r05 General Specifications This manual will help you install and maintain the IP67 Industrial Ethernet Switch Installation of these switches will enable the user to manage the network by monitoring gathering network data allow for browser or telnet configuration increase network performance and more Note This manual only covers the installation and wiring of these switches Refer to the separate Software User Ma
10. l a managed only o F O O O JO O D Pressure ET a Vent Plug T T O o 5 O 7 9 4 S 9 ET 8xS MIL i N a N N N O oe m aa o gt 0 O D o O O O O O O O O O O O O O O Power Input a with plug installed H AS no backshell and E wiring not shown g typical i SZ J D Pi A 2 91 74 0mm 3 98 101 1mm ET 8xS MIL_manual r05 Page 6 of 9 Last Revised 29 Apr 13 Sixnet e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 4 Overview below Power and Communication Wiring The IP67 Industrial Switches can be powered from the same DC source that is used to power your other devices 10 to 30 VDC needs to be applied between Pin A and Pin B as shown NOTE Any of the available mounting holes may be used for grounding and electrical bonding of the switch No Connection Shell A Insert 98 Contacts P Keying A Power Input Wiring All Models ET 8xS MIL ET 8xS MIL_manual r05 Page 7 of 9 also allowed due to the auto mdi mdix crossover No No Connection Connection TX TX RX Shell A Insert 35 Contacts S Keying N Ethernet Wiring All Models ET 8xS MIL RS232 and USB USB CNX USB DM VBUS 3 RS232 TD output RS232 RD input shell A Insert 35 Contacts S Keying A Console Port Wiring Managed Models ET 8MS MIL RS232 USB Last Revised
11. nual for details on configuring and using any of the management functions such as SNMP RSTP IGMP port mirroring etc The IP67 Industrial Ethernet Switch can support 10BaseT 10 Mbps or 100BaseT 100 Mbps on all ports Each of these ports will independently auto sense the speed allowing you to interface to regular 10Mb or fast Ethernet 100Mb devices The IP67 Industrial Ethernet Switch meets the following standards plus others General 8 Fast Ethernet ports Ethernet switch type Managed or Unmanaged Ethernet protocols supported All IEEE 802 3 MIL DTL 38999 Series IlI w 22D socket female contacts olive drab cadmium plating 9 35 MIL DTL 38999 Series III w 22D socket female contacts olive drab ke a 9 35 Auto crossover S Typical less frame time Varies on load amp setings Power Automatic power savings when ports are unused Power input receptacle with a DTL 38999 Series Ill w pin male contacts 9 98 size olive drab cadmium plating Input voltage all models 0 30 VDC continuous Input power typical with all 3 W unmanaged ports linked and active 4 W managed 5 000 watts 10x for 10 uS or 250 volts 50x for 100 uS 40 to 75 C cold startup at 40 C 5 to 95 RH Conformal coating avaible by special order emo Ce UL508 CSA C22 EN61010 1 EMC emissions MIL STD 461E FCC part 15 ICES 003 EN55022 and IEC61326 1 immunity Hazardous locations Class l ANSI ISA 12 12 01 CSA C
12. or upgraded versions of the same product to take advantage of new features and performance improvements at any time for five years A prorated trade in allowance will be given for your existing equipment Sixnet protects your long term productivity with state of the art planned technology and continued support Sixnet Statement of Limited Warranty Sixnet manufacturer of Sixnet products warrants to Buyer that products except software manufactured by Sixnet will be free from defects in material and workmanship sixnet s obligation under this warranty will be limited to repairing or replacing at Sixnet s option the defective parts within one year of the date of installation or within 60 months of the date of shipment from the point of manufacture whichever is sooner Products may be returned by Buyer only after permission has been obtained from Sixnet Buyer will prepay all freight charges to return any products to the repair facility designated by Sixnet This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation maintenance misuse neglect or any cause other than ordinary commercial or industrial applications In particular Sixnet makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose All such warranties are hereby expressly disclaimed No oral or written information or advice given by Sixnet or Sixnet s repres

Download Pdf Manuals

image

Related Search

Related Contents

Technical Data Sheet  BenQ DC P860 User`s Manual  ASPEN USER MANUAL - Earth Observing Laboratory  Manuel d`utilisation INGEREV  PV ストリング監視装置 SMP2101/SMP2201 取扱説明書  MANUAL DE INSTRUÇÕES MEGÔMETRO DIGITAL MI-2700  Eglo 90686A Installation Guide  User Guides - Eventide Inc. www homepage  LinkMotion and Leetro MPC6515 for Laser  平成23年企業団公告第8号 長野県上伊那広域水道用水企業団 企  