Home

CPC504 User Manual

image

Contents

1. SSD Front panel and onboard components are not shown g Support KIB584 Kit p Angle Bar KIB584 Kit The module s components layout may slightly differ for various versions of the module SSD is not included in the MIC584 supplied set itis ordered separately The capacity of the SSD can be 160 GB or 80 GB CPC504 User Manual 66 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel LE CPC504 Figure 7 6 MIC584 Front Panel 128 4 The module s components layout may slightly differ for various versions of the module CPC504 User Manual 67 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 3 Specifications Audio controller High Definition Audio compatible codec Line input Un 1 V RMS XP5 3 pin onboard connector Line output output resistance Z 10 K XP6 3 pin onboard connector Microphone input Un 1 V RMS at 0 db amplification Un 0 1 V RMS at 20 db amplification front panel connector Headphones output output resistance Z 65 ohm front panel connector m Two USB ports Conform to USB 2 0 specification Front panel connectors R
2. O e O _3 max 34 7 ta 165 5 LI Ee 211 7 _ lt lolo Table 1 2 Dimensions for Different Types of Heatsinks 301415 019 0SX77 AavidThermalloy RI 17 5 20 20 5 301415 019 02 0SX98 AavidThermalloy R2 29 31 5 32 301415 019 03 SK463 FischerElektronik R2 33 35 5 36 301415 019 01 SK120 FischerElektronik R2 38 40 5 41 CPC504 User Manual 19 2011 Fastwel Ver 002a E Introduction Fastwel EN CPC504 Figure 1 8 CPC504 01 02 Module Dimensions with R2 Heatsink 8HP gd N j Il SE ol n 7 m P C w fat UT UT GT I Kai TUTO TH mA Figure 1 9 CPC504 03 04 Module Dimensions with R1 Heatsink and MIC588 F EIST CN e See M n T3 era fi ari GT
3. Figure 7 3 MIC584 Components Layout and Dimensions Top rs 08 CEI XP2 O lees O SE MIC584 bag XP1 Ga O O E 5 d D2 X84 e la e CH o ell po 8 e o Ing XS5 CA XP5 4 2 X82 DO XPZ WG XS1 Sa cla a O o LE X83 XP6 O O DI 88 3 The module s components layout may slightly differ for various versions of the module CPC504 User Manual 64 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 Figure 7 4 MIC584 Components Layout Bottom Co UIJ 0 The module s components layout may slightly differ for various versions of the module CPC504 User Manual 65 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Lee CPC504 Figure 7 5 MIC584 with 160 GB SSD Installed Adapter Plate KIB584 Kit oe ols 09000009 KIB584 v 2 0 Le je N i
4. Figure 1 10 CPC504 03 04 Module Dimensions with R2 Heatsink and MIC588 The appearance may vary for different versions of the module CPC504 User Manual 20 2011 Fastwel Ver 002a E Introduction Fastwel Lee CPC504 1 3 5 Front Panel Figure 1 11 CPC504 01 02 4HP Front Panel jaa Kal 2 N jaa Ra 2 L2 Eth2 20 32 Upper Retaining Screw SVGA Connector USB Sockets Status LEDs L1 and L2 Gigabit Ethernet 2 Socket Gigabit Ethernet 1 Socket Ejector Handle Programmable Switch Lower Retaining Screw The appearance may slightly differ for various versions of the module CPC504 User Manual 21 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 Figure 1 12 CPC504 03 04 Front Panel DVI1 ACT J L2 pa USBI ay I I Eth2 DVI2 Eth1 The appearance may slightly differ for various versions of the module The buttons of ejector handles are used to unlock the assembly More
5. 5V 3 3V CH7307 DVI CH7307 DVI Transmitter Transmitter g Ha 2 g CPC504 Mezzanine Connector 2x SDVO Channels CPC504 User Manual 77 2011 Fastwel Ver 002a E MIC588 2xDVI Module Fastwel Tp CPC504 8 4 MIC588 Layout Figure 8 2 MIC588 Layout Side Facing CPC504 MIC588 a XS2 Co lt K lt XS5 oo The layout of your product may slightly differ from the shown above CPC504 User Manual 78 2011 Fastwel Ver 002a E MIC588 2xDVI Module Fastwel Lee CPC504 8 5 DVI D Connectors Two digital monitors can be connected to MIC588 front panel connectors the pinout is shown below Table 8 1 DVI D Connector Pinout 1 DATA2 16 HP_DETECT 2 DATA2 17 DATAO 3 DTA2 SHIELD 18 DATAO 4 NC 19 DTAO_SHIELD 5 NC 20 NC 6 DDC_CLK 21 NC 7 DDC_DAT 22 CLK_SHIELD 8 NC 23 CLOCK 9 DATAI 24
6. The module is developed on order MIC584 is a mezzanine interface expansion module It is designed to be installed on the top side of CPC504 processor module and is connected via J2 connector An 1 8 SATA HDD or SSD can be installed on MIC584 using KIB584 adapter module MIC584 has the following interfaces and connectors Mm Six RS232 and RS485 serial ports one D Sub connector on the front panel COM1 and four IDC connectors on board Two USB 2 0 ports Type A front panel connectors OneLPT on board header for connection of a PC compatible printer or other devices with parallel interface E Two SerialATA connectors on board Audio Interface front panel sockets for connection of a microphone Mic and headphones Phone and Line In Out headers onboard E 6 pin PS 2 keyboard mouse front panel connector P Two LEDs on the front panel CPC504 User Manual 28 2011 Fastwel Ver 002a E Introduction Fastwel LE CPC504 MIC588 mezzanine interface expansion module is designed to be installed on the bottom side of CPC504 and connected to the processor module via J1 connector versions 03 and 04 This module occupies the next slot to the left of CPC504 and is powered via the backplane Additionally they provide possibility to direct video output to the RIO588 rear expansion module The detailed description of expansion modules can be found in relevant sections of this Manual CPC504 User Manual 29 2011 Fastwel Ve
7. 1 2 3 Unscrew the B and C screws fixing the heatsink Install standoffs into A B C and D openings Install MIC584 module engaging its XS6 connector with J2 connector of CPC504 and fix with screws at positions A B C and D The details on connection of external devices to MIC584 module can be found in Section 7 of this manual CPC504 User Manual 56 2011 Fastwel Ver 002a E Configuration Fastwel LE CPC504 4 Configuration 4 1 PCI Express Operation Modes J18 jumper located on the top side of the CPC504 module is used for switching between two PCI Express operation modes one x4 link or four x1 Table 4 1 PCI Express Operation Mode Selection l Closed One x4 o6 Open Four x1 4 2 Clear CMOS If the system is not booted for example due to incorrect BIOS settings it is possible to clear BIOS Setup parameters stored in CMOS memory using Programmable switch To clear CMOS memory follow the procedure below 1 Switch power off 2 Press the button Programmable switch on the ejector handle and slightly open the ejector handle but do not move the module out of its slot 3 Switch power on 4 Waituntil L2 red LED starts blinking fast and move the ejector handle back to the locked position by lifting it until the click 5 Start BIOS Setup utility F2 to configure the system CPC504 User Manual 57 2011 Fastwel Ver 002a E Ph
8. Figure 1 7 Figure 1 8 Figure 1 9 Figure 1 10 Figure 1 11 Figure 1 12 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 3 1 Figure 7 1 Figure 7 2 Figure 7 3 Figure 7 4 Figure 7 5 Figure 7 6 Figure 7 7 Figure 7 8 Figure 7 9 Figure 7 10 Figure 7 11 Figure 7 12 Figure 7 13 Figure 7 14 Figure 8 1 Figure 8 2 CPC504 Block Diagrami iuacndarto ae aaa 13 CPC504 Module Appearance with R2 Heatsink eee e ee niieeeeeeeeteecaeeeeeeeeeeeea 14 CPC504 Module Appearance Without Heataink i 15 CPC504 03 and 04 Bottom de 16 CPC504 Module Layout Top Side onsneeeeeeeeenneneeeeeeeeeirntttsettttrntttsettttrnnttsetttnnnnttseentennntnneeeen nn 17 CPC504 03 and 04 Module Layout Bottom Ode 18 CPC504 Module Dimensions with R1 Heatemnk e 19 CPC504 01 02 Module Dimensions with R2 Heatsink GHP 20 CPC504 03 04 Module Dimensions with R1 Heatsink and MIC588 20 CPC504 03 04 Module Dimensions with R2 Heatsink and MIC588 cc ccceceeeeeeeeeeetteeeeeeaes 20 CPC504 01 02 4HP Front Panel 21 CPC504 03 04 Front Panels cis cicieseitiieiniiinniidi nadine ENEE Eeer 22 CompactPCI Connectors J1 and J2 di 42 J2 Expansion Connector for MIC584 Mezzanine Module 45 USB1 J22 n USB2 J16 Gockets ennet 46 SVGA J45 Front Panel Connector tin ieee naire eee enn naaeeeeeeeetencnaeeeeeeeetneea 48 Ethernet EIDEN ssaa 49 SD Card Socket ile 50 Fixing o
9. CPC504 User Manual 50 2011 Fastwel Ver 002a E Detailed Description Fastwel LE CPC504 2 3 10 1 L2 Indicator Configuration and Control Registers Table 2 11 L2 Indicator Configuration and Control Registers 30h R W 00h Activate Bit 0 to 1 LED module is active Base 0 R W Oih LED data register 3 0 The rest bits are nonsignificant are read as 0 60h R W Base 15 8 I O port base address bits 15 8 61h R W Base 7 0 I O port base address bits 7 0 To work with L2 indicator it is necessary to set the base address for the device LDN 5 and activate it as it is done for the watchdog timer or FRAM module L2 indicator is controlled via LED register Subsequent operation is performed in I O area in relation to the specified base address 2 3 10 2 LED Register Initialization To initialize the register follow the following procedure e Enter configuration mode MOV DX 302H MOV AL 46H OUT DX AL MOV AL 57H OUT DX AL e Write to LDN register a logic device number LED register has logical number 5 MOV DX 302H MOV AL 7 OUT DX AL MOV DX 303H MOV AL 5 OUT DX AL e Set base address for the device in I O area for example 31dh MOV DX 302H MOV AL 60H OUT DX AL MOV DX 303H MOV AL 3H OUT DX AL MOV DX 302H MOV AL 61H OUT DX AL MOV DX 303H MOV AL 1dH OUT DX AL CPC504 User Manual 51 2011 Fastwel
10. FSB 800 MHz D co unt suo vea LPC Interfac lui bai o KEE 2 965GME DI S GMCH a0 Er g gt oe x GG LJ 5 O la N S Sie Gigabit A S 3 Ethernet de 5 a Controller De al GbEthernet SPI Flash Multiplexor BIOS Ee en 8 Mbit lt gt 2 Gigabit ai SI Sc Ethernet wi e O 5 ey Controller PCI E Bus S gt USB to GN m Secure Secure S e 2 z Digital Digital E amp Bridge Card Socket So NH Ww GN Sr 5a Sg J rs Ges eee Seem CPU Core VR I RRS SS SS 1 FPGA if x sl a S I Os Ge a I I at lt On a GMCH VR I n ag E 55 32 bit PCI Bus PCI PCI I E oO a 2 I l Bridge DDR VR i i 5 FRAM I I a Power Supply I Mezzanine Connector J2 I 2 CPC504 User Manual 2011 Fastwel Ver 002a E 13 Introduction Fastwel LBs CPC504 1 3 2 Module Appearance Figure 1 2 CPC504 Module Appearance with R2 Heatsink The appearance may vary for different versions of the module CPC504 User Manual 14 2011 Fastwel Ver 002a E Introduction Fastwel To CPC504 Figure 1 3 CPC504 Module Appearance Without Heatsink The appearance may vary for different versions of the module CPC504 User Manual 15 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 Figure 1 4 CPC504 03 and 04 Bottom Side TL ITUPFRFETT The appearance may v
11. Serial ports are realized in SMSC SCH3116 Super I O chip Figure 7 8 COM1 Front Panel Connector COM1 is a non isolated RS 232 serial port It is routed to 9 pin D Sub connector at MIC584 front panel Its pinout is presented in the table below Table 7 2 COM1 Serial Port Pinout 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RIN 5 GND Figure 7 9 COM2 COM6 Serial Ports IDC2 10 Connector 2 00000 10 COM2 COM6 non isolated serial ports are routed to 2 row 10 pin 1 00000 o IDC2 10 onboard connectors XP11 XP13 Their pinout is presented in the table below Table 7 3 RS 232 COM2 COM4 XP11 XP13 Pinout 1 DCD 6 CTS 2 DSR 7 DTR 3 RXD 8 RIN 4 RTS 9 GND 5 TXD 10 NC COM5 and COM6 non isolated RS 485 serial ports are routed to XP7 IDC2 10 onboard connector its pinout is presented in the table below CPC504 User Manual 71 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 Table 7 4 RS 485 COM5 and COME XP7 Pinout 1 P1_DATA P1_DATA GND GND P2_DATA P2_DATA 10 Not used COM5 COM6 N OD Om AJOJN If the port is at the end of the line connection of 120 ohm terminating resistor is required It is done by closing pins of XP3 COM5 and XP4 COME 2 pin contacts 7 5 2 2 USB Interfaces Figure 7 10 USB3 and USB4
12. about 35 watts the consumption of the remaining system components possible variations of power consumption during operation e g due to temperature changes and some reserve Taking all this into account it is recommended to use a 150 watt power supply If possible power supplies with voltage sensing should be used This may require an appropriate backplane Consumption currents for CPC504 are 3 3 V 2 A 5V 6 A CPC504 User Manual 60 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 MIC584 Mezzanine Expansion Module 7 1 Introduction MIC584 mezzanine expansion module is designed for installation on Fastwel s CPC504 CompactPCI 3U processor module This mezzanine I O module expands functionality and I O capability of the CPC504 MIC584 module is installed on the top side of the CPC504 processor module and connected via the J2 connector 7 1 1 MIC584 Versions At the present time the module is supplied in two versions MIC584 01 I and MIC584 01 C They have the same functionality and differ in the operating temperature range as shown in the table below Table 7 1 MIC584 Versions Differences MIC58401 1 40 to 85 MIC58401 C 0 to 70 Protective coating can be applied as an option COATED 7 1 2 MIC584 Delivery Checklist The MIC584 supplied set includes MIC584 mezzanine module PS 2 Y cable Two SATA data cables SATA power cable Two jumpers for XP3 XP4 MIC584
13. key to CONFIG PORT To exit the configuration mode write lt 57h gt lt 46h gt key to CONFIG PORT INDEX and DATA ports are available in configuration mode only CPC504 User Manual 32 2011 Fastwel Ver 002a E Fastwel Lee Detailed Description CPC504 Watchdog Timer Programming The procedures of watchdog programming is described below e Enter configuration mode MOV DX 302H MOV AL 46H OUT DX AL MOV AL 57H OUT DX AL e Write to LDN register a logic device number watchdog timer has logical number 1 MOV DX 302H MOV AL 7 OUT DX AL MOV DX 303H MOV AL 1 OUT DX AL e Watchdog timer registers are available for read and write now For example to read status register 3Eh and to write the value from it back MOV DX 302H MOV AL 3EH OUT DX AL MOV DX 303H IN AL DX OUT DX AL e To exit configuration mode MOV DX 302H MOV AL 57H OUT DX AL MOV AL 46H OUT DX AL Global Configuration Registers 7h R W 01h Logical Device Number Logical Device Number register index 7h Index 7h Write Read Writing to this register selects logical device 7 0 LDN CPC504 User Manual 33 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 Logical Device 1 Configuration Registers Watchdog Timer 30h R W Activate 38h Base 0 R W Timer current value 7 0 39
14. AR EEA dear 46 2 3 5 Graphics Controller iii aa ei aa de 47 2 3 5 1 DVM Technology 47 2 3 5 2 Supported Resolutions eee icine eee eee eter eee neaaeeeeeeeeneenaeeeeeeereneea 47 2 3 5 3 CRT Interface and Conpector cece ee ieee ee eee eentieeeeeeeeeteciaeeeeeeerteeeee 48 2 3 6 Serial Interfaces RS232 and RS485 i 49 2 3 7 Parallel Port Interface ria ed Lasa nia T iaia iaia eee ede deeds 49 CPC504 User Manual 1 2011 Fastwel Ver 002a E Fastwel Ley CPC504 2 3 8 Gigabit EE 49 2 3 9 Socket for Secure Digital Card 50 2 3 10 LED elle TEE 50 2 3 10 1 L2 Indicator Configuration and Control Registers AAA 51 2 3 10 2 LED Register Initialization ee eet ieee teen aeeeeeeeeetetaeeeeeeeeeneee 51 2 3 10 3 LED Register Bits oneeeeeeeeeeeeeeereetneeeternnttstetttruntttetttnnnntascettnnnnnnacettennnnnaeeent 52 3 JE Ed ET 53 3 1 Safety Heoulattone ANEN 53 3 2 Installation Procedure afraid 54 3 9 Ke Re E UE 54 3 4 Peripheral Devices Installation eee i 55 3 4 1 USB Devices Installation i ccarcneracna fa nave ene naar 55 3 4 2 Secure Digital Cards Inetallation AAA 55 3 4 3 Battery ReplacemMent i 55 3 5 Installation of MIC584 Mezzanine Expansion Module eee eenaeeeeeeeeetenaeeeeeeeeenenea 56 4 CGonfig ration iii eave vd dance eee acne ed adaa adaa 57 4 1 PCI Express Operation MOde S ictisesenceccspetsescdect det sagessecodescd
15. CLOCK 10 DATA1 25 NC 11 DTA1_SHIELD 26 NC 12 NC 27 NC 13 NC 28 NC 14 5V_PWR 29 AGND 15 GND CPC504 User Manual 2011 Fastwel Ver 002a E 79 Supplementary Information Fastwel Le CPC504 9 Supplementary Information 9 1 Related Standards and Specifications The Fastwel s CompactPCI modules comply with the requirements of the following standards Table 9 1 Related Standards CE Emission EN50081 1 CE Immission EN61000 6 2 CE Electrical safety EN60950 2002 Mechanical dimensions IEEE 1101 10 Vibration sinusoidal IEC60068 2 6 82 Fc 5 g 10 500 Hz 10 acceleration frequency range test cycles per axis Permanent shock IEC60068 2 29 87 Eb 50 g 11ms 1000 10 1s peak acceleration shock duration half sine number of shocks recovery time Single shock IEC60068 2 27 87 Ea 100g9 9ms 18 3s peak acceleration shock duration number of shocks recovery time in seconds Important AK Some versions of the module may have the test results differing from the ones presented in the above table For more information please contact Fastwel s official representatives Information related to this product and its components can be found in the following specifications Table 9 2 Related Specifications CompactPCI Systems and Boards CompactPCI Specification 2 0 Rev 3 0 CPC504 User Manual 80 2011 Fastwel Ver 002a E Useful Abbreviations Acronyms and
16. Connectors 1234 MIC584 has two USB Type A front panel connectors for connection of USB 2 0 devices USB interfaces provide port For connection of more than two devices to MIC584 module use external USB hub 2 480 Kb s transfer rate One device can be connected to each Table 7 5 USB3 and USB4 Connectors Pinout 1 VCC VCC signal 2 UVO Differential USB In Out 3 UV0 Differential USB In Out 4 GND GND signal Note For each USB port maximum current is 0 5 A All signal lines are EMI filtered CPC504 User Manual 72 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 5 2 3 PS 2 Keyboard Mouse Interface Figure 7 11 PS 2 Connector 3 PS 2 interface is realized in SMSC SCH3116 Super I O chip 5 1 Standard 6 pin PS 2 MiniDIN connector is located on the front panel of MIC584 PS 2 keyboard and mouse can be connected 2 simultaneously using Y cable supplied with MIC584 module 6 4 Table 7 6 PS 2 Connector Pinout 1 KDATA Keyboard data In Out 2 MDATA Mouse data In Out 3 GND GND signal 4 VCC VCC signal 5 KCLK Keyboard clock Out 6 MCLK Mouse clock Out Note xX Keyboard mouse power supply unit is protected by a 500 mA fuse All signal lines are EMI filtered 7 5 2 4 Audio Interface Two standard audio connectors are located on MIC584 f
17. However to guarantee a stable system in unsteady industrial environment both the internal and the external thermal monitors should be enabled These two monitors protect the processor and the whole system against overheating Note XK Thermal Management functions should be disabled when performing Benchmarks and performance tests otherwise the results will be incorrect due to the power reduction processes influence CPC504 User Manual 59 2011 Fastwel Ver 002a E Thermal and Power Issues Fastwel Ley CPC504 6 1 2 Active Regulation To provide controlled active heat dissipation CPC504 is equipped with a specially designed heatsinks Together with a system chassis with adjustable forced air flow capability this provides a basis for reliable and steady operation Forced air flow of sufficient volume is vital for high performance processors operating in high temperature environments When developing applications using the CPC504 the system integrator must take into account the overall system thermal requirements System chassis must satisfy these requirements When performing thermal calculations for certain application the developer must consider the contribution of peripherals to be used with the CPC504 to the total heat emission These devices must also be capable to operate at the temperatures within the system operating range especially those which are attached directly to the CPC504 processor module Warning A Since Fastwe
18. MIC588 front panel or to CompactPCl connectors to be available via RIO588 rear I O module The output is switched with the help of BIOS Setup utility on CPC504 Front panel output is indicated by the ACT LED MIC588 is powered via CompactPCI backplane MIC588 is included in the supplied set of versions 03 and 04 of the CPC504 processor module and normally is not supplied separately 8 2 Specifications Mm SDVO DVI transmitters MIC588 includes two SDVO DVI transmitters Transmission rate 165 megapixels s Resolution up to UXGA 1600x1200 single channel DVI D Two DVI D ports Front panel connectors Software switchable output to front panel or rear I O m Other The module is connected to CPC504 processor module via Samtec high speed differential connector Front panel output mode indicator Does not require forced air cooling Dimensions a 3U cPCI 181 3 mm x 100 mm 4HP E Power 43 3 V 5 200 MA 5 V 5 380 mA Shock Vibration stability Vibration 5g Single shock 100g Multiple shock 50g CPC504 User Manual 76 2011 Fastwel Ver 002a E MIC588 2xDVI Module Fastwel LE CPC504 8 3 MIC588 Block Diagram Figure 8 1 MIC588 Block Diagram DIR LED N E 3 S D ps D 8 6 2 E 2 5V o E E 4 6 2 2 LL O Voltage D Regulator O CH e 2 D e e gt D DVI DDC Switch DVI DDC Switch
19. Manual 44 2011 Fastwel Ver 002a E Fastwel Ley CPC504 Detailed Description 2 3 2 Connectors for Mezzanine Modules A number of interface expansion modules are used to enhance I O capabilities of CPC504 MIC584 mezzanine module is installed on the top side to the right of CPC504 processor module 60 contact J2 high speed connector socket is used for connection of MIC584 MIC588 mezzanine module is installed on the bottom side to the left of the CPC504 versions 03 and 04 and occupies the backplane connector next to CPC504 80 contact J1 high speed differencial type connector socket is used for connection The pinout of J1 connector is not described in this document since MIC588 and CPC504 03 04 are supplied bodily Figure 2 2 J2 Expansion Connector for MIC584 Mezzanine Module B1 B30 A1 A30 Table 2 5 Pinout of J2 Connector for MIC584 Mezzanine Module A1 5V B1 5V A2 5V B2 5V A3 USB_PNO B3 USB_PN1 A4 USB_PPO B4 USB_PP1 A5 GND B5 GND A6 SATA_TXNO B6 SATA_RXNO A7 SATA_TXPO B7 SATA_RXPO A8 GND B8 GND AQ SATA_TXN1 B9 SATA_RXN1 A10 SATA_TXP1 B10 SATA_RXP1 A11 GND B11 GND A12 AZ_BITCLK B12 LPC_ADO A13 GND B13 LPC_AD1 A14 AZ_SYNC B14 LPC_AD2 A15 AZ_RST B15 LPC_AD3 A16 AZ_SDIN B16 LPC_FRAME A17 A
20. basis without warranty Fastwel assumes no liability for consequential or incidental damages originated by the use of this software This document contains information which is property of Fastwel Co Ltd It is not allowed to reproduce it or transmit by any means to translate the document or to convert it to any electronic form in full or in parts without antecedent written approval of Fastwel Co Ltd or one of its officially authorized agents Fastwel and Fastwel logo are trademarks owned by Fastwel Co Ltd Moscow Russian Federation CompactPCI is a trademark of the PCI industrial Computers Manufacturers Group Ethernet is a registered trademark of Xerox Corporation IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers Inc Intel is a trademark of Intel Corporation Pentium M and Celeron M are trademarks of Intel Corporation Microsoft is a trademark of the Microsoft corporation In addition this document may include names company logos and trademarks which are registered trademarks and therefore are property of their respective owners Fastwel welcomes suggestions remarks and proposals regarding the form and the content of this Manual CPC504 User Manual 4 2011 Fastwel Ver 002a E Fastwel LE CPC504 Notation Conventions Warning ESD Sensitive Device This symbol draws your attention to the information related to electro static sensitivity of your product and its components To keep pro
21. by user see details in LED Indicators section Gigabit Ethernet status 1 and 2 n Line green Line connected a Act green Network activity Programmable Switch D Can be used for manual initialization of the system Integrated into the ejector handle Thermal Management Processor is protected from overheating by n Internal processor temperature control unit which initiates CPU shut down n Processor die temperature monitor Memory chips temperature monitor a Custom designed heatsinks Temperature Monitors LM87 hardware monitor is used for supervision of the on die CPU temperature and the board surface temperature LM95235 for the memory chips temperature monitoring Real Time Clock n Built in ICH8M Watchdog Timer a Realized in FPGA n Programmable timeout period n Selectable NMI IRQ or Reset signals generation CPC504 User Manual 26 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 1 4 4 General Mechanical 3U CompactPCl form factor Dimensions 130 4 x 212 5 x 20 32 mm 5 13 x 8 37 x 0 8 Module Weight 380 g max Power Supply 5 V 45 3 3 V 5 from CompactPCI connector See Section 6 2 for details on power supply requirements Temperature Ranges Operational CPC504 1 400 85 CPC504 C 0 C 70 C Storage 55T 85 Humidity 0 to 80 RH non condensing Battery 3 0 V lithium battery for RTC in a battery holder Use Panasonic BR2032 or compatible 1 4 5 Software So
22. two versions for industrial 40 C to 85 C and for commercial 0 C to 70 C temperature ranges C2D2 2 is available for commercial temperature range only At the present time CPC504 is available in the following off the shelf configurations Table 1 1 Off the Shelf Configurations of CPC504 CPC504 01 C2D1 6 RAM4096 R1 C CPC504 01 C2D1 6 RAM4096 R2 CPC504 02 CS1 0 RAM2048 R1 C CPC504 02 CS1 0 RAM2048 R1 CPC504 02 C2D1 6 RAM2048 R1 C CPC504 02 C2D1 6 RAM2048 R2 CPC504 02 C2D2 2 RAM4096 CPC504 02 C2D2 2 RAM4096 R2 C commercial range only PC504 03 C2D2 2 RAM4096 CPC504 03 C2D2 2 RAM4096 R2 C commercial range only CPC504 04 C2D1 6 RAM4096 R1 C CPC504 04 C2D1 6 RAM4096 R2 CPC504 01 C2D1 6 RAM4096 CPC504 02 CS1 0 RAM2048 CPC504 02 C2D1 6 RAM2048 CPC504 04 C2D1 6 RAM4096 Other configuration options are available upon request The customer can choose necessary configuration options using the following template nem ee ae 1 Basic product name CPC504 2 Version 01 _ 02 03 3 Processor CS1 0 Intel Celeron ULV 573 512 KB L2 cache 1 00 GHz 533 MHz FSB 10 W C2D1 6 Intel Core 2 Duo L7500 4 MB L2 cache 1 6 GHz 800 MHz FSB 17 W C2D2 2 Intel Core 2 Duo T7500 4 MB L2 cache 2 2 GHz 800 MHz FSB 35 W C2D2 2 commercial range only CPC504 User Manual 11 2011 Fastwel Ver 002a E Introduction Fastwel Lee CPC504 Exa
23. 04 versions 01 and 03 is equipped with soldered NAND flash memory modules with IDE interface up to 50 MB s having total capacity of up to 4 GB for storing user programs and data It can be used as a boot disk 2 2 4 2 Secure Digital Socket The CPC504 has a standard socket for SD cards connected to an internal USB 2 0 port Maximum capacity of SD cards is 16 GB 2 2 4 3 FRAM Emergency Storage for User Data Fast serial FRAM 32 KB is installed on the module 1 KB is used by manufacturer 31 KB is available for storage of critical user data in case of power supply failure FRAM device registers and programming is described below FRAM Registers Logical device 3 30h R W Activate Base 0 R W 00h FRAM address value 7 0 Base 1 R W 00h FRAM address value 14 8 Base 2 R W 00h FRAM data value 7 0 Base 3 R W 00h FRAM Control register 7 1 reserved 0 autoincrement mode 60h R W Base 15 8 I O port base address bits 15 8 61h R W Base 7 3 I O port base address bits 7 3 Base 2 0 must be 0 To work with FRAM it is necessary to set the base address for the device LDN 83 and activate it the same way it is done for the watchdog timer Subsequent operation is performed in I O area in relation to the specified base address Bit lt 0 gt of the Control register Base 3 enables the address autoincrement mode for reading from writing to the Data register Base 2 FRAM
24. 1 In Out 18 GND 6 INIT Out 19 ACK In 7 PD2 In Out 20 GND 8 SLCTIN Out 21 BUSY In 9 PD3 In Out 22 GND 10 GND 23 PE In 11 PD4 In Out 24 GND 12 GND 25 SLCT In 13 PD5 In Out 26 GND _ CPC504 User Manual 74 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 5 2 7 SerialATA Interface External SATA drives can be connected to MIC584 via two standard onboard SerialATA connectors XP8 and XP10 For installation of a 1 8 disk drive on MIC584 the KIB584 adaptor is used power to the drive is supplied via XP9 connector KIB584 adaptor is a part of ACS20044 set which is not supplied with MIC584 and can be ordered separately Figure 7 14 SerialATA Connector IS TUTTO J Recommended SATA cable length 45 cm The pinout is in the table below Table 7 10 SerialATA Connector Pinout 5 1 GND RXN 2 TXP RXP 3 TXN 7 GND 4 GND CPC504 User Manual 75 2011 Fastwel Ver 002a E MIC588 2xDVI Module Fastwel Tp CPC504 8 MIC588 2xDVI Module 8 1 Introduction MIC588 is a mezzanine 3U cPCI interface expansion module equipped with two DVI D connectors It is designed to be installed on the bottom side of Fastwel s CPC504 CompactPCI 3U processor module versions CPC504 03 and 04 only and connected via the J1 connector Video output can be directed either to the
25. 3 2011 Fastwel Ver 002a E Introduction Fastwel LE CPC504 1 4 2 Interfaces CompactPCl Bus Interface Compliant with CompactPCI Specification PICMG 2 0 R3 0 PCI Express n n Serial Ports Parallel Port USB Interface System master operation 32 bit 33 MHz master interface 3 3V 5 0V compatible Up to 7 bus master devices Individual clocks for PCI devices PCI PCI bridge asinchronous mode support Routed to Rear I O module connector Configurable as one x4 or four x1 Connectors on mezzanine or Rear I O module Realized via LPC interface Connector on MIC584 mezzanine or Rear I O module IEEE1284 ECP EPP Five USB 2 0 ports USB1 and USB2 two Type A connectors on the CPC504 front panel USB3 and USB4 routed to MIC584 via J2 connector USB5 available via Rear I O Gigabit Ethernet Two 10 100 1000 Mb s Gigabit Ethernet interfaces based on the Intel 82574L GbE PCI Express bus controllers Graphics Two RJ45 connectors on the front panel Switchable between front panel and Rear I O Automatic mode recognition Automatic cabling configuration recognition Cabling requirement Category 5 UTP four pair cabling Built in graphics controller High performance Intel Graphics Media Accelerator GMA Video memory up to 384 MB shared with system CRT monitors with resolutions of up to 2048 x 1536 32 bit at 75 Hz Dual SDVO support available via two DVI D connectors at MIC588 module Video output switchable betw
26. AN from the onboard SD cards from soldered 4 GB NAND flash memory disk or from SATA II up to 300 MB s drives located on MIC584 mezzanine expansion module or on a rear I O module The MIC584 mezzanine module supports two SATA Il interfaces with option to mount either SATA DOM solid state modules or one standard 1 8 SATA disk drive Six COM ports two USB 2 0 PS 2 and audio interfaces are available via the MIC584 module as well CPC504 supports FreeDOS Windows XP Embedded and Linux 2 6 operating systems TBA CPC504 User Manual 9 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 Some of the CPC504 s basic features are 4HP 3U CompactPCI form factor m Intel processors Celeron ULV 573 1 0 GHz 512 KB L2 cache 533 MHz FSB Core 2 Duo L7500 1 6 GHz 4 MB L2 cache 800 MHz FSB Core 2 Duo T7500 2 2 GHz 4 MB L2 cache 800 MHz FSB Intel chipset 82965GME GMCH and ICH8M Up to 4 GB of soldered dual channel DDR2 SDRAM memory with 64 bit addressing PCI bus 32 bit 33 MHz System master PCI Express four x1 or one x4 routed to rear I O Flash BIOS SPI interface 8 Mbit In system modification CMOS SFRAM for configuration parameters storage FRAM 31 KB available to user a Watchdog timer Programmable timeout period NMI IRQ or Reset signals generation FPGA firmware upgrade capability a Integrated high performance graphics controller 2D accelerator Up to 384 MB me
27. CPC504 Fastwel assumes no responsibility for any damage resulting from infringement of these rules Warning When handling or operating the module special attention should be paid to the heatsink because it can get very hot during operation Do not touch the heatsink when installing or removing the module Moreover the module should not be placed on any surface or in any kind of package until the module and its heatsink have cooled down to ambient temperature Caution If your module does not allow hotswapping switch off the system power before installing the module in a free slot Disregarding this requirement could be harmful for your life or health and can damage the module or entire system ESD Sensitive Equipment This product comprises electrostatically sensitive components Please follow the ESD safety instructions to ensure module s operability and reliability gt gt E n Use grounding equipment if working at an anti static workbench Otherwise discharge yourself and the tools in use before touching the sensitive equipment m Try to avoid touching contacts leads and components Extra caution should be taken in cold and dry weather CPC504 User Manual 53 2011 Fastwel Ver 002a E Installation Fastwel Ley CPC504 3 2 Installation Procedure To install CPC504 in a system follow the instructions below 1 Keep to the safety regulations of the Section 3 1 when performing the following oper
28. Connector J2 J3 System Slot PINOUL i 44 Pinout of J2 Connector for MIC584 Mezzanine Module 45 USB1 and USB2 Pinouts CPC504 Front Panel 46 Partial List of Supported Display Modes AA 48 SVGA J45 Front Panel Connector Pinot 48 Gigabit Ethernet Connectors Pimnoute 49 L1 and L2 Front Panel Indicators inne er nani reer ere aaeeeeee ee teenaaeeeeeeeeneenaaeees 50 L2 Indicator Configuration and Control Registers A 51 LED GontrolRegisteriBits EE 52 L2 LED Operation Modes iuiiiciiana laicale 52 PCI Express Operation Mode Selection 57 DC Input Voltage Ranges and Lime 60 MIC584 Versions DIfferences ttt ntnattttnrttastttrnnnnananennn ntenni 61 GOMIT Senal Port Pinout 3 a5 e255 eines Mieco arn MiG Mea ra eG D eg geseet 71 RS 232 COM2 COM4 XP11 XP13 PINOUt 71 RS 485 COM5 and COME XP7 Pinout 72 USB3 and USB4 Connectors Pinot 72 PS 2 Connector Pinot 73 LINE_IN XP5 Connector Pinot 73 LINE OUT XP6 Connector PINoUt rihanna 74 LPT Connector Pinout italia 74 SerialATA Connector PINOUt ire i nn etree aaee eee e ee nennaeeeeeeeetneea 75 DVI D Gonnector PINOUT escrire iaiia aiaa ea 79 Helated Gtandarde AAA 80 Related Specifications atei die ab aa ea ana 80 CPC504 User Manual 3 2011 Fastwel Ver 002a E Fastwel Ley CPC504 List of Figures Figure 1 1 Figure 1 2 Figure 1 3 Figure 1 4 Figure 1 5 Figure 1 6
29. Description Fastwel Tp CPC504 2 3 Module Interfaces 2 FRENA 2 3 1 CompactPCI Bus Connectors Hi ajia Figure 2 1 CompactPCI Connectors J1 and J2 gt H EE The CPC504 is designed for a CompactPCI bus architecture HH but it utilizes only two of standard CompactPCI connectors aoe J1 and J2 The CompactPCI standard is electrically identical LELE to the PCI local bus However these systems are improved to i FRERES support multiple slots and to operate in harsh industrial tits environments EEC J1 stadard CompactPCI connector is marked as J6 on board EEA J2 is marked as J3 H J1 2 3 1 1 CompactPCI Connector Color Coding HA IMI finan Guide lugs on CompactPCI connectors serve to ensure a HH correct mating of connectors A proper mating is guaranteed Note AAAA also by the use of color coded keys for 3 3V and 5V g et BBSS A e i e F and Z operation Color coded keys prevent accidental installation of ai EDCRA a 5V module into a 3 3V slot CompactPCI backplane GND pins connectors keying depends always on the signaling VIO level On universal backplanes supporting both sinalling levels VIO level is selected by a jumper on the backplane CPC504 is a universal module with 3 3V or 5V signalling voltage level Coding key colors are described below Table 2 2 CompactPCI Connector Coding Colors 3 3 V Cadmium Yellow 5V Brilliant Blue Universal module 5V and 3 3V None C
30. Fastwel TE CPC504 3U CompactPCI Intel Core 2 Duo Based Processor Module User Manual Rev 002a E October 2011 The product described in this manual is compliant with all related CE standards Product Title CPC504 Document name CPC504 User Manual Manual version 002aE Ref docs CPC504 UM v1 05 R Copyright 2011 Fastwel Co Ltd All rights reserved Revision Record 001 Initial preliminary version CPC504 MIC584 MIC588 October 2010 002 Multiple amendments CPC504 MIC584 MIC588 September 2011 002a Reviewed names of connectors CPC504 MIC584 MIC588 October 2011 Contact Information Fastwel Co Lid Fastwel Corporation US Address 108 Profsoyuznaya st 45 Main Street Suite 319 Moscow 117437 Brooklyn New York 11201 Russian Federation USA Tel 7 495 232 1681 1 718 554 3686 Fax 7 495 232 1654 1 718 797 0600 Toll free 1 877 787 8443 1 877 RURUGGED E mail info fastwel com Web http www fastwel com Fastwel Ley CPC504 Table of Contents Table of Contenis Tila iL See oe sks hn eee ee ee Laica 1 RE eu 3 Be e Le EE 4 Notation Conventions Auge deed EES Gand on rile e ae ei 5 General Safety PIECAUTIONs v ala aaa 6 Unpacking Inspection and Handling 7 Three Year Warranty isso sna ene nie leoni le aaa nale iaia 8 1 introduction corfas RR RO 9 1 1 OO RE EEA 9 127 CPC504 Vereiong EE 11 9 GPC504 DiagramS iatale aria 12 1 3 1 Block RTE
31. IRQ1 02h SMI 03h IRQ3 04h IRQ4 05h IRQ5 06h IRQ6 3 0 Interrupt_select 07h IRQ7 08h IRG8 Interrupt disabled 09h IRQ9 Oah IRQ10 Obh IRQ11 Och IRQ12 Odh IRQ13 Interrupt disabled Oeh IRQ14 Interrupt disabled Ofh IRQ15 Interrupt disabled CPC504 User Manual 35 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 Timer Init register Index Fih 7 5 Not used Write Read Counter reset on writing to 80h port 1 Enabled 0 Disabled Write Read Counter reset on writing cycle to window 2 1 Enabled 0 Disabled Write Read Counter reset on reading cycle from window 2 1 Enabled 0 Disabled Write Read Counter reset on writing cycle to window 1 1 Enabled 0 Disabled Write Read Counter reset on reading cycle from window 1 1 Enabled 0 Disabled 4 P80E 3 WND2_WR_EN 2 WND2_RD_EN 1 WND1_WR_EN 0 WND1_RD_EN Window 1 port base address registers Index F2h Write Read Bits 7 0 of Window 1 base address 7 0 Window1_Base_Adress 7 0 Index F3h Write Read Bits 15 8 of Window 1 base address 7 0 Window1_Base_Adress 15 8 Window 2 port base address registers Index F4h Write Read Bits 7 0 of Window 2 base address 7 0 Window2_Base_Adress 7 0 Index F5h Write Read Bits 15 8 of Window 2 base add
32. MS TDO TDI GND 1 GND 5V 12V TRST 12V 5V GND CPC504 User Manual 2011 Fastwel Ver 002a E 43 Detailed Description Fastwel Lee CPC504 Table 2 4 32 bit CompactPCI Bus Connector J2 J3 System Slot Pinout 22 GND GA4 GA3 GA2 GAI GAO GND 21 GND CLK6 GND 3 3V AC_SDIN AC_BIT_CLK GND 20 GND CLK5 GND AC_SDOUT AC_RST AC_SYNC GND 19 GND GND GND BP I O BP I O BP I O GND 18 GND GBE2 MD3N GBE2 MDIN GND PCI_RST PCI SERIRQ GND 17 GND GBE2 MD3P GBE2 MDIP PRST REQ6 GNT6 GND 16 GND GBE2 MD2N GBE2 MDON DEG GND PCI_CLK GND 15 GND GBE2 MD2P GBE2 MDoP FAL REQ5 GNT5 GND 14 GND VGA BLUE VGA_HSYNC GBE1_MD2N VGA VSYNC GBE1_MDON GND 13 GND VGA_GREEN GBE1_MD3N GBE1_MD2P GBE1_MDiN GBE1 MDOP GND 12 GND VGA_RED GBE1_MD3P VGA DDCCLK GBE1_MD1P VGA DDCDAT GND 11 GND USB DATA SATA2 RXN 5v 5V SMB_DATA GND 10 GND USB DATA SATA2 RXP SATA2 TXN SMB CLK GND GND 9 GND LPC_LAD3 LPC_LFRAME SATA2 TXP GND PE_CLK_N GND 8 GND LPC_LAD2 PE4 TN GND PE4 RN PE CLK P GND 7 GND LPC_LAD1 PE4 TP PE3 TN PE4 RP PE3_RN GND 6 GND LPC_LADO PE2 TN PE3 TP PE2 RN PE3_RP GND 5 GND LPC_LDRQ PE2 TP PE1_TN PE2 RP PE1_RN GND 4 GND V I O GND PE1 TP GND PE1_RP GND 3 GND CLK4 GND GNT3 REQ4 GNT4 GND 2 GND CLK2 CLK3 SYSEN GNT2 REQ3 GND 1 GND CLK1 GND REQ1 GNT1 REQ2 GND CPC504 User
33. Programming The procedures of FRAM programming is described below e Enter configuration mode MOV DX 302H MOV AL 46H OUT DX AL MOV AL 57H OUT DX AL CPC504 User Manual 39 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 e Write to LDN register a logic device number FRAM has logical number 3 MOV DX 302H MOV AL 7 OUT DX AL MOV DX 303H MOV AL 3 OUT DX AL e Set base address for the device in I O area for example 310h MOV DX 302H MOV L 60H OUT DX AL MOV DX 303H MOV L 3H OUT DX AL MOV DX 302H MOV L 61H OUT DX AL MOV DX 303H MOV L 10H OUT DX AL e Activate the device MOV DX 302H MOV AL 30H OUT DX AL MOV DX 303H MOV AL 1H OUT DX AL e To exit configuration mode MOV DX 302H MOV AL 57H OUT DX AL MOV AL 46H OUT DX AL Further operations with FRAM are performed in I O area at addresses 310h 313h e Write data byte 32h to FRAM address 144h MOV DX 310H MOV L 44H OUT DX AL MOV DX 311H MOV L 01H OUT DX AL MOV DX 312h MOV L 32h OUT DX AL CPC504 User Manual 40 2011 Fastwel Ver 002a E Detailed Description Fastwel Le CPC504 e Reading data byte from FRAM address 101h MOV DX 310H MOV AL 01H OUT DX AL MOV DX 311H MOV AL 10H OUT DX AL MOV DX 312h IN AL DX CPC504 User Manual 41 2011 Fastwel Ver 002a E Detailed
34. SD precautions carefully take the product out of the shipping carton box Proper handling of the product is critical to ensure correct operation and long term reliability When unpacking the product and whenever handling it thereafter be sure to hold the module preferably by the front panel card edges or ejector handles Avoid touching the components and connectors Retain all original packaging at least until the warranty period is over You may need it for shipments or for storage of the product Initial Inspection Although the product is carefully packaged it is still possible that shipping damages may occur Careful inspection of the shipping carton can reveal evidence of damage or rough handling Should you notice that the package is damaged please notify the shipping service and the manufacturer as soon as possible Retain the damaged packing material for inspection After unpacking the product you should inspect it for visible damage that could have occurred during shipping or unpacking If damage is observed usually in the form of bent component leads or loose socketed components contact Fastwel s official distributor from which you have purchased the product for additional instructions Depending on the severity of the damage the product may even need to be returned to the factory for repair DO NOT apply power to the product if it has visible damage Doing so may cause further possibly irreparable damage as well as result in a f
35. Short cuts Fastwel Lee CPC504 10 Useful Abbreviations Acronyms and Short cuts BMC Baseboard Management Controller PM Peripheral Management Controller IPMI Intelligent Platform Management Interface IPMB Intelligent Platform Management Bus DC Inter Integrated Circuit Two thread serial protocol used in SMB and IPMI KCS interface Keyboard Controller Style interface Interface for communication between control software and BMC similar to a keyboard controller interface BT interface Block Transfer interface Block transfer interface for communication between control software and BMC DDR SDRAM Double Data Rate Synchronous Dynamic Random Access Memory SODIMM Small Outline Dual In Line Memory Module ECC Error Correction Code Data error correction technology used in memory modules FWH Firmware Hub Nonvolatile memory chip part of Intel chipset used for main and reserve BIOS copies in CPC504 GMCH Graphics and Memory Controller Hub DAG Digital Analog Converter USB Universal Serial Bus LPC Low Pin Count External devices communication interface SMB System Management Bus UART Universal Asynchronous Receiver Transmitter UHCI Universal Host Controller Interface USB Host Controller Interface EHCI Enhanced Host Controller Interface Universal Serial Bus specification UTP Unshielded Twisted Pair CRT display Cathode Ray Tube Display PMC PCI Per
36. TEEN 13 1 3 2 Module Appearance uiuriiedlalea nia aE EE dale aaa dies 14 1 3 3 ele ET 17 1 3 4 Module Dimenslong tenere tanne e rnnr EEEE EEEE EAEE EEEEEEEEEEEEEEEE EEEE EEE EEE EEEE AEAEE AEREE EEEE EEEEEEEE 19 1 3 5 PLOMUR Ane ET 21 1 4 Ener ee GEET 23 1 4 1 Processor Memory and Chipset teran a EEEE E EAEE 23 1 4 2 attert 24 1 4 3 Control and Monitorifig x uuscslanazesia lese a asa ia 26 1 4 4 Generali laicale ear 27 1 4 5 SoftWale Lo iui eil E ae 27 1 5 Delivery Checklist i 28 LE System Expansion MOdules csccccsscssscetecstesnisessaceencseesakssancces RS ae 28 2 Detailed Description sarei 30 2 1 Processor Memory and Chipeet ee i nn ri eee nae e eee een dee eeee ee tnenaeeeeeeee enna 30 2 1 1 PIOCESSOl icaro 30 2 1 2 ER Eu TTT 30 2 1 3 Intel Chipset EE 31 2 2 InternaliPeripheralS i a cai elia 31 2 2 1 TIME Sienan gle AER 31 2 2 1 1 Watehdog RUE 32 2 2 2 Batten yes ege SEENEN 38 2 2 3 Local SMBus Devices ernier iarara a arar a aE E E AEE ara a Ea aaa i aen 38 2 2 4 Flash MEMO EE TEE 39 2241 NON Elek often 39 2 2 4 2 Secure Ree Ee TEE 39 2 2 4 3 FRAM Emergency Storage for User Data 39 ER Wee Tu 42 2 3 1 CompactPCI Bus Connectors 42 2 3 1 1 CompactPCI Connector Color Coding 42 2 3 1 2 CompactPCI Connectors J1 and J2 Pinouts 43 2 3 2 Connectors for Mezzanine Modules nnne 45 2 3 3 Keyboard Mouse Interface ET 46 2 3 4 USB Interia ESen npa iene EEA EE
37. Ver 002a E Detailed Description Fastwel Ley CPC504 e Activate the device MOV DX 302H MOV AL 30H OUT DX AL MOV DX 303H MOV AL 1H OUT DX AL e To exit configuration mode MOV DX 302H MOV AL 57H OUT DX AL MOV AL 46H OUT DX AL 2 3 10 3 LED Register Bits Table 2 12 LED Control Register Bits Sam Red LED Red LED Green LED Green LED Reserve bits are read as 0 eu Bito SP Bito L2 LED indicator consists of two independent red and green LEDs Thus it can glow green red or orange red and green are both on Each LED is independently controlled via the LED register bits Operation mode for each LED is set by values in two bits as shown in the table below Table 2 13 L2 LED Operation Modes 0 0 LED is off 0 1 Fast blinking 8 Hz 1 0 Slow blinking 1 Hz 1 1 Steady light CPC504 User Manual 52 2011 Fastwel Ver 002a E Installation Fastwel Tp CPC504 3 Installation The CPC504 is easy to install However it is necessary to follow the procedures and safety regulations below to install the module correctly without damage to the hardware or harm to personnel The installation of the peripheral drivers is described in the accompanying information files For details on installation of an operating system please refer to the relevant software documentation 3 1 Safety Regulations The following safety regulations must be observed when installing or operating the
38. Z_SDOUT B17 GND A18 3 3V B18 SERIRQ A19 KBRST B19 3 3V A20 A20GATE B20 DRQO A21 3 3V B21 3 3V A22 PLT_RST B22 SMB_CLK A23 GND B23 SMB_DATA A24 CLK_33MHz B24 GND A25 GND B25 USB_OC 0 A26 CLK_14MHz B26 USB_OC 1 A27 GND B27 3 3VA A28 CLK_32kHz B28 INIT_3V3 A29 GND B29 BIOS_DIS A30 5VA B30 5VA CPC504 User Manual 2011 Fastwel Ver 002a E 45 Detailed Description Fastwel Ley CPC504 2 3 3 Keyboard Mouse Interface A keyboard and a mouse can be connected to CPC504 using front panel USB sockets Moreover PS 2 mouse and keyboard can be connected to a standard 6 contact MiniDIN connector on MIC584 front panel Mouse and keyboard can be connected simultaneously using Y cable CPC504 includes 8042 compatible keyboard controller emulator realized on FPGA This is necessary for correct operation of supported operating systems when CPC504 is used without MIC584 2 3 4 USB Interfaces The CPC504 supports five USB 2 0 ports Two ports USB1 and USB2 are available on CPC504 front panel via two Type A connectors Two ports USB3 and USB4 are routed to J2 connector and are available at MIC584 mezzanine module One more port USB5 is routed to CompactPCl connector to be used via a rear I O module Figure 2 3 USB1 J22 n USB2 J16 Sockets 1234 All ports support high speed full speed and low speed operation Hi speed USB 2 0 supports data transfer rate of up to 480 Mb s than five USB devices
39. and HD mounting kit Antistatic bag for MIC584 Consumer package Note XK Keep all the original packaging material antistatic bag and consumer package for future storage or warranty shipments SE E E Vi A CPC504 User Manual 61 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Loe CPC504 7 2 MIC584 Appearance and Layout The figures in this section are supposed to help you to locate and identify the module s components and connectors Our constant efforts in improving our products may result in minor differences between the real module and its depictions 7 2 1 MIC584 Appearance Figure 7 1 MIC584 Appearance The appearance of your product may slightly differ from the shown above CPC504 User Manual 62 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Lee CPC504 Figure 7 2 MIC584 Appearance with SATA SSD Installed Draft The appearance of your product may slightly differ from the shown above CPC504 User Manual 63 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 2 2 MIC584 Components Layout
40. ary for different versions of the module MIC588 is not shown Versions 01 and 02 are not equipped with J1 connector CPC504 User Manual 16 2011 Fastwel Ver 002a E Introduction Fastwel Len CPC504 1 3 3 Module Layout Figure 1 5 CPC504 Module Layout Top Side Panel De SDRAM Buzzer GMCH CPU SVGA 3 USBI s CC USB2 o Status LEDs CE o e J2 NAND Flash Ejector Handle Battery Ethernet C J3 cPCI J2 J18 J6 cPCI J1 SD Memory Card The layout may slightly differ for various versions of the module Heatsink is not shown CPC504 User Manual 17 2011 Fastwel Ver 002a E Introduction Fastwel Lee CPC504 Figure 1 6 CPC504 03 and 04 Module Layout Bottom Side PCI PCI Bridge ICH8M Ji The layout may slightly differ for various versions of the module MIC588 is not shown Versions 01 and 02 are not equipped with J1 connector CPC504 User Manual 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 1 3 4 Module Dimensions Figure 1 7 CPC504 Module Dimensions with R1 Heatsink x il 9 o 0 O
41. asiaGannaginedunaennG 74 C5216 LPT INEA S eege ee eege ease ae eege Ee ess 74 T5257 EEN Bu caiano hacen 75 8 MIC588 2x DVI TT TT 76 8 1 Introduciion ai ar o ana 76 Ee neu 76 8 3 IMIC588 Block Diagramm eege e eene deet EEN dE ae 77 B MIC588 Layout leleine en heehee 78 8 5 DV Do COMMECTONS i e cece ltecihescnesuteatteeg inann lis aaa lola ea 79 CPC504 User Manual 2 2011 Fastwel Ver 002a E Fastwel Ley CPC504 9 Supplementary Information rciiiiiiin 80 9 1 Related Standards and Speciti ationS ENEE 80 10 Useful Abbreviations Acronyms and ShOrt CU S rriiiiiii 81 List of Tables Table 1 1 Table 1 2 Table 1 3 Table 2 1 Table 2 2 Table 2 3 Table 2 4 Table 2 5 Table 2 6 Table 2 7 Table 2 8 Table 2 9 Table 2 10 Table 2 11 Table 2 12 Table 2 13 Table 4 1 Table 6 1 Table 7 1 Table 7 2 Table 7 3 Table 7 4 Table 7 5 Table 7 6 Table 7 7 Table 7 8 Table 7 9 Table 7 10 Table 8 1 Table 9 1 Table 9 2 Off the Shelf Configurations of CPC504 tt ri nae teeter ne naeeeeeeeettenaeeeeeeeeeneea 11 Dimensions for Different Types of Heatsinks eeetteee eter eee eecneeeeeeeeeeeencaaeeeeeeeeteenaaeees 19 Interface Expansion Modules AAA 28 SMBUS DEVICES Liri 38 CompactPCI Connector Coding Colors i 42 CompactPCI Bus Connector J1 46 System Slot Pinot 43 32 bit CompactPCI Bus
42. ations A Ensure that the module configuration corresponds to the application requirements before installing For information regarding the configuration of the CPC504 refer to Chapter 4 For the installation of CPC504 specific peripheral devices and I O devices refer to the appropriate sections in Chapter 3 For details on installation of expansion modules refer to respective sections of this document To install the CPC504 Warning Failure to accomplish the following instruction may damage the module or result in incorrect system operation 1 Make sure that no power is connected to the system 2 Avoiding contact with other modules of the system carefully insert the module into the chosen slot until it contacts the backplane connectors Do not apply force pushing the module into the backplane connectors 3 Using the front panel ejector handle engage the module with the backplane The module is completely engaged when the ejector handle is locked For versions 03 and 04 ensure simultaneous locking of both handles Fix the module with the front panel retaining screws 5 Connect the required external interfacing cables to the module s connectors and make sure that the module and all connected cables are properly fixed The CPC504 is now ready for operation Please refer to appropriate software application and system manuals to get further instructions 3 3 Removal Procedure To remove the module from th
43. duct safety and operability it is necessary to handle it with care and follow the ESD safety directions Warning This sign marks warnings about hot surfaces The surface of the heatsink and some components can get very hot during operation Take due care when handling avoid touching hot surfaces Caution Electric Shock This symbol warns about danger of electrical shock gt 60 V when touching products or parts of them Failure to observe the indicated precautions and directions may expose your life to danger and may lead to damage to your product Warning Information marked by this symbol is essential for human and equipment safety Read this information attentively be watchful Note This symbol and title marks important information to be read attentively for your own benefit SE gt b gt CPC504 User Manual 5 2011 Fastwel Ver 002a E Fastwel Ley CPC504 General Safety Precautions This product was developed for fault free operation Its design provides conformance to all related safety requirements However the life of this product can be seriously shortened by improper handling and incorrect operation That is why it is necessary to follow general safety and operational instructions below A A amp Warning All operations on this device must be carried out by sufficiently skilled personnel only Warning When handling this product special care must be taken not to hit the heatsink
44. e independent transmit and receive queues to limit PCI E bus traffic and a PCI E interface providing efficient bus utilization by increased use of bursts Figure 2 5 Ethernet Connectors Act Link Two RJ45 Gigabit Ethernet connectors are located on CPC504 front panel J24 The interfaces provide auto detection and switching between 10Base T 100Base TX and 1000Base T operation modes Each of the two Ethernet channels may be software switched to rear I O to provide system flexibility Table 2 9 Gigabit Ethernet Connectors Pinouts 1 O TX O TX I O BI_DA 2 O TX O TX I O BI_DA 3 RX RX I O BI_DB 4 I O BI_DC 5 I O BI_DC 6 RX RX I O DI D 7 I O BI_DD 8 I O BI_DD MDI Standard Ethernet Cable CPC504 User Manual 49 2011 Fastwel Ver 002a E Detailed Description Fastwel Lee CPC504 Integrated Ethernet LEDs Line green This LED indicates network connection The LED lights up when the line is connected Act green this LED monitors network activity The LED lights up when network packets are sent or received through the RJ45 port When this LED is not lit it means that the computer is not sending or receiving net
45. e system case do the following 1 SCH Pe Do TO When performing the next actions keep to safety regulations of the Section 3 1 Pay special attention to the temperature of the heatsink Ensure that the system power is switched off before proceeding Disconnect all cables that may be connected to the module Unscrew the front panel retaining screws Unlock the module ejection handle s by pressing the integrated button s and then press on the handle s until the module connectors are disconnected from the backplane Carefully pull the module out of the slot Do not touch the heatsink since it can get very hot during operation Dispose of the module at your discretion The module should not be placed on any surface or in any form of package until the board and the heatsink have cooled down to room temperature CPC504 User Manual 54 2011 Fastwel Ver 002a E Installation Fastwel Tp CPC504 3 4 Peripheral Devices Installation A lot of peripheral devices can be connected to the CPC504 Their installation procedures differ significantly Therefore the following sections provide mainly general guidelines regarding installation of peripheral devices 3 4 1 USB Devices Installation The CPC504 can accept Plug amp Play connection of USB 2 0 computer peripheral devices printers keyboards mice etc All USB devices may be connected or disconnected while the host power is on 3 4 2 Secure Digital Cards Installation SD socke
46. ebvanjaecsdeeoceindseiens aaa aa 57 42 Cleat CMOS sissies ee i ia ILL ALI capt AE REH 57 5 Phoenix BIOS Se tu pice E 58 5 1 Boot RTE 58 5 1 1 Booting without a Monitor Keyboard or Mouse i 58 5 1 2 Begotpecttom HES tegen lle ile iii lele serene 58 6 Thermal and Power ISSUES ccrrieiiii iii 59 6 1 Temperature Control insana ion nali aaa calar lalla ea 59 6 1 1 Passive e EE 59 6 1 2 en He UE e EE 60 6 2 System e TTT 60 7 MIC584 Mezzanine Expansion MOdUle cirie 61 7 1 Introduction aaa ai 61 7 1 1 MIC584 Versions i n a a a n a E 61 7 1 2 MIC584 Delivery Checklist i 61 7 2 MIC584 Appearance and Layout 62 7 2 1 MIG584 ee le lu 62 7 2 2 MIC584 Components Layout iiiciiciiidsniieen ae aaa 64 K WEE le EE 68 Z MIG584 Block Diagrami x saletta leale ha ale 69 Zb MI 584 Mefa ES alal Lala la lo elle neh ell alii ai 70 7 5 1 MIC584 Interfaces List i 70 7 5 1 1 Front Panel 4HP Interfaces ANNE 70 Zack Ilnternalilnterfaces alri e een eege a 70 7 5 2 MIC584 Interfaces Detailed Description 71 15 21 Serial InterfaceS cisiiundisanina deal lana ea 71 7 522 USB INS ACS oi li ul 72 7 5 2 3 PS 2 Keyboard Mouse Interface 73 7 5 2 4 Audio Interface tr nnn eet e eee aaee ease et nnnaeeeeeren enna 73 7 0 2 5 L3 and l4 LEDSisuuscnungiuncennoaunaannasnn
47. een supplied Failure to package in antistatic material will VOID all warranties Then package the product in a safe container for shipping 4 The customer pays for shipping the product to Fastwel or to an official Fastwel representative or dealer CPC504 User Manual 8 2011 Fastwel Ver 002a E Introduction Fastwel Tp CPC504 1 Introduction 1 1 Overview The product described in this Manual is CPC504 a 3U CompactPCI PICMG 2 0 host processor module based on low power dual core Intel Core 2 Duo CPUs operating at 1 6 GHz or 2 2 GHz with 4 MB level 2 cache and featuring 800 MHz system bus The processor executes up to 8 floating point operations per clock cycle and can address up to 4 GB of soldered DDR2 system memory in 64 bit mode The list of processors includes also an ultra low voltage Intel Celeron 573 with 512 KB L2 cache operating at 1 GHz supporting 533 MHz FSB An increased heatsink for CPU and chipset cooling with effective surface area of up to 682 cm allows efficient heat dissipation within wide ambient air temperature range For high speed data exchange CPC504 employs two Gigabit Ethernet channels four x1 PCI Express lanes configurable also as one x4 slot and 32 bit PCI bus The integrated graphics controller of Intel 965GME supports output of two independent video streams to VGA interface or to two DVI D interfaces available at MIC588 mezzanine expansion module The firmware of CPC504 supports booting from L
48. een front panel and Rear I O External graphics controller support via PCI E x16 CPC504 User Manual 24 2011 Fastwel Ver 002a E Introduction Fastwel LBs CPC504 HD Audio Realized on mezzanine MIC584 or on Rear I O module Line input output optional Microphone input Headphones output E 5 1 and 7 1 modes supported Keyboard and Mouse E USB KB and MS can be directly connected to CPC504 E PS 2 port is available at MIC584 front panel mouse and keyboard simultaneous connection is possible via Y cable Secure Digital Socket E Connected to internal USB 2 0 port D Up to 16 GB cards supported Flash Disk a Soldered NAND flash disk 4 GB ver 01 and 03 a IDE interface up to 50 MB s n Software disconnectable D Can be used as bootable disk FRAM E 1 KB is used by the manufacturer n 31 available to user FPGA E Keyboard controller functionality E LED indicators control n Watchdog timer control SATA Interface n Three ports two connectors on mezzanine module one on Rear I O E SATA and SATA Il modes supported Flash BIOS n 8 Mb serial EEPROM with SPI interface n In system modification CPC504 User Manual 25 2011 Fastwel Ver 002a E Introduction Fastwel To CPC504 1 4 3 Control and Monitoring LED Indicators System status E L1 Activity indicator Yellow SD memory card Red SATA or flash disks E L2 Startup process monitoring Special system states indication Programmable
49. elect register index 70h Write Read Timeout flag It is set to 1 on expiry of the timeout This flag 0 TMF enables interrupt generation Cleared by writing 1 into this bit or by writing to 80h port or on access to windows 1 or 2 on condition that one of these modes is enabled Control Register Base 7h 7 3 Reserved Write Read j CNTE mee ead Writing 1 enables watchdog countdown Write Read RSTE 9 S Writing 1 enables Reset on timeout 2 2 2 Battery The CPC504 utilizes a 3 0 V lithium battery for the RTC and CMOS memory backup Use Panasonic BR2032 or compatible Batteryless operation is possible with no RTC function 2 2 3 Local SMBus Devices The CPC504 incorporates a System Management Bus to access several system monitoring and control devices via a two wire IC bus interface The following table presents functions and addresses of onboard SMBus devices Table 2 1 SMBus Devices 1 0D2H SLG8SP533V System clock generator 2 OAOH and 0A2H SPD EEPROM module 3 5CH LM87 PCB amp CPU temperature sensor 4 4CH LM95235 RAM temperature sensor Upon request temperature monitors can report information on temperatures of system components to system control facilities ensuring safe operation CPC504 User Manual 38 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 2 2 4 Flash Memory 2 2 4 1 NAND Flash The CPC5
50. ers Timers Three 8254 type counters timers integrated in ICH are available on the CPC504 M Additional Timer The ICH includes an additional programmable timer which prevents system hang ups during start ups After the first time out period is over it generates the SMI signal which starts the software hang up recovery subroutine If the second timeout ends the Reset signal is issued to recover the system from the hardware hang up state CPC504 User Manual 31 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 E Watchdog Timer The watchdog timer eliminates system hang ups both during the start up process for example in case of mistakes in BIOS when the additional timer is not able to restart the system and during normal operation The timeout period is set in BIOS Setup program On the expiry of the timeout period the watchdog timer issues the Reset signal or SMI or an interrupt During start up process watchdog timer monitors the BIOS code execution and resets the system in case of activation error The instructions on watchdog timer programming can be found in the following subsections 2 2 1 1 Watchdog Timer Watchdog timer is realized in FPGA XC3S250E as a LPC device Watchdog timer consists of 24 bit Counter register Timer Current Value Register decremented with frequency of 32 768 kHz and Initial value register Timer Initial Value Register On expiry of the timeout period either interrupt or SMI
51. f MIC584 on CPC504 noniis enia Ge einai 56 MIC584 Appearance EEN 62 MIC584 Appearance with SATA SSD Installed A 63 MIC584 Components Layout and Dimensions Top 64 MIC584 Components Layout Bottom nnna 65 MIC584 with 160 GB SSD Installed i 66 MIG584 Front Panel alal aaa ian 67 GPG504 Block Diagrami i ariana iaia aaa 69 COMI Front Panel Connector 71 COM2 COM6 Serial Ports IDC2 10 Connector s sssessseeeseeseeerirrtttseretrrrrttserttrnnnnteetttnnnntnneetennnn 71 USB3 and USB4 Connectors iano lane gna liana aaa 72 PS 2 Connector ia rssaalsgataa ideali ae ei ana 73 LINE_IN XP5 and LINE_OUT XP6 Connectors 73 RRE ele E E EE 74 SerialATA Connect 75 lee lp el Rici 77 MIC588 Layout Side Facing CPC504 78 All information in this document is provided for reference only with no warranty of its suitability for any specific purpose This information has been thoroughly checked and is believed to be entirely reliable and consistent with the product that it describes However Fastwel accepts no responsibility for inaccuracies omissions or their consequences as well as liability arising from the use or application of any product or example described in this document Fastwel Co Ltd reserves the right to change modify and improve this document or the products described in it at Fastwel s discretion without further notice Software described in this document is provided on an as is
52. f the following devices E 82965GME Graphics and Memory Controller Hub GMCH m ICH8M I O Controller Hub North Bridge The 965GME GMCH provides interfaces with the CPU via Front Side Bus FSB with dual channel DDR2 SDRAM system memory interface to high performance internal graphics controller or external graphics controller via x16 PCle link It also provides DMI interface to the ICH The internal graphics controller allows connection of analog and digital displays Power management features include ACPI 3 0 support and Dynamic FSB frequency switching South Bridge The ICH8M 82801HBM is a multifunctional I O Controller Hub that provides interface to the 32 bit PCI Bus and configurable PCI Express bus as well as to such PC interfaces as one UltraDMA100 IDE channel three SATA II channels ten USB 2 0 ports internal real time clock with CMOS power controller supporting ACPI and APM Support for LPC interface HD audio and SPI is also provided 2 2 Internal Peripherals The following internal peripherals are available on the CPC504 module 2 2 1 Timers CPC504 is equipped with the following timers E RTC Real Time Clock The ICH contains a MC146818A compatible real time clock The RTC includes 256 bytes of battery backed CMOS RAM The RTC features include timekeeping with alarm function and 100 year calendar as well as programmable periodic interrupt A coin cell battery powers the real time clock and CMOS memory M Count
53. ftware BIOS Flash memory based enhanced Phoenix BIOS has the following features BIOS boot support for USB keyboards Software enable disable function for the Rear I O Ethernet and COM ports configuration Plug amp Play capability Ethernet boot option Onboard peripherals enable disable function CPU power management features Programmable handle switch function Programmable LED control FRAM enable option MIC584 amp MIC588 configuration options Operating Systems Supported operating systems a FreeDOS preinstalled E Microsoft Windows XPe E Linux 2 6 CPC504 User Manual 27 2011 Fastwel Ver 002a E Introduction Fastwel LBs CPC504 1 5 Delivery Checklist The CPC504 delivery set includes 1 CPC504 processor module 2 PCI Express configuration jumper 3 Antistatic bag 4 Consumer carton box Note XK Keep the antistatic bag and the original package at least until the warranty period is over It can be used for future storage or warranty shipments 1 6 System Expansion Modules To expand system I O capabilities Fastwel offers a number of interface modules Each of these modules is available in two versions differing in operating temperature range Table 1 3 Interface Expansion Modules MIC584 Mezzanine kit interface module Via J2 mezzanine connector MIC588 Mezzanine DVI module Via J1 mezzanine connector Installed on CPC504 03 04 RIO588 Rear DVI module for MIC588 cPCI connector
54. h Base 1 R W Timer current value 15 8 3ah Base 2 R W Timer current value 23 16 3bh Base 3 R W 00h Timer initial value 7 0 3ch Base 4 R W 40h Timer initial value 15 8 3dh Base 5 R W 00h Timer initial value 23 16 3eh Base 6 R W 00h Status register 3fh Base 7 R W 03h Control register 60h R W Base 15 8 I O port base address bits 15 8 61h R W Base 7 3 I O port base address bits 7 3 Base 2 0 should be 0 70h R W 00h Primary interrupt select FOh R W 00h Reserved Eih R W 00h Timer Init Register F2h R W 00h Window 1 base address bits 7 0 F3h R W 00h Window 1 base address bits 15 8 F4h R W 00h Window 2 base address bits 7 0 F5h R W 00h Window 2 base address bits 15 8 F6h R W FFh Window 1 Mask bits 7 4 Window 2 Mask bits 3 0 Activate register Index 30h 7 1 Not used Write Read 0 Activate 1 Current logical device enabled 0 Current logical device disabled CPC504 User Manual 34 2011 Fastwel Ver 002a E Detailed Description Fastwel LE CPC504 UO port base address registers Index 60h Write Read Current logical device base address bits 15 8 7 0 O_Base_Adress 15 8 Index 61h Write Read Current logical device base address bits 7 0 7 0 O_Base_Adress 7 0 Primary interrupt select register Index 70h 7 4 Not used Write Read 00h Interrupt disabled 01h
55. ible by human being static discharge can be sufficient to destroy or degrade a component s operation Therefore all handling operations and inspections of this product must be performed with due care in order to keep product integrity and operability m Preferably unpack or pack this product only at EOS ESD safe workplaces Otherwise it is important to be electrically discharged before touching the product This can be done by touching a metal part of your system case with your hand or tool It is particularly important to observe anti static precautions when setting jumpers or replacing components D If the product contains batteries for RTC or memory back up ensure that the module is not placed on conductive surfaces including anti static mats or sponges This can cause short circuit and result in damage to the battery and other components D Store this product in its protective packaging while it is not used for operational purposes Unpacking The product is carefully packed in an antistatic bag and in a carton box to protect it against possible damage and harmful influence during shipping Unpack the product indoors only at a temperature not less than 15 C and relative humidity not more than 70 Please note that if the product was exposed to the temperatures below 0 C for a long time it is necessary to keep it at normal conditions for at least 24 hours before unpacking Do not keep the product close to a heat source Following E
56. if installed against another rigid object Also be careful not to drop the product since this may cause damage to the heatsink CPU or other sensitive components as well Please keep in mind that any physical damage to this product is not covered under warranty Note This product is guaranteed to operate within the published temperature ranges and relevant conditions However prolonged operation near the maximum temperature is not recommended by Fastwel or by electronic chip manufacturers due to thermal stress related failure mechanisms These mechanisms are common to all silicon devices they can reduce the MTBF of the product by increasing the failure probability Prolonged operation at the lower limits of the temperature ranges has no limitations Caution Electric Shock Before installing this product into a system and before installing other devices on it always ensure that your mains power is switched off Always disconnect external power supply cables during all handling and maintenance operations with this module to avoid serious danger of electrical shock CPC504 User Manual 6 2011 Fastwel Ver 002a E Fastwel LE CPC504 Unpacking Inspection and Handling Please read the manual carefully before unpacking the module or mounting the device into your system Keep in mind the following ESD Sensitive Device A Electronic modules and their components are sensitive to static electricity Even a non percept
57. ipheral Component Interconnect Mezzanine Card CMC Common Mezzanine Card LVDS Low Voltage Differential Signal Digital monitors communication specification RTC Real Time Clock BIOS Basic Input Output System PC Personal Computer PICMG PCI Industrial Computer Manufacturers Group AHA Accelerated Hub Architecture GMCH and ICH communication bus specification CPC504 User Manual Fastwel 81 2011 Ver 002a E Useful Abbreviations Acronyms and Short cuts Fastwel Lee CPC504 AGP Accelerated Graphics Port AGTL Advanced Gunning Transceiver Logic PSB Processor Side Bus signal exchange specification SMBus System Management Bus EEPROM Electrically Erasable Programmable Read Only Memory NAND Flash Not And electronic logic gate Flash memory specification SSD Solid State Disk PLCC Plastic Leaded Chip Carrier RAMDAC Random Access Memory Digital to Analog Converter DAC Digital to Analog Converter DVMT Dynamic Video Memory Technology TTL Transistor Transistor Logic ECP EPP Extended Capabilities Port Enhanced Parallel Port Parallel port specifications FDD Floppy Disk Drive EIDE Enhanced Integrated Drive Electronics Mass storage devices interface DMA Direct Memory Access PIO Programmed Input Output EIDE Directly processor controlled data exchange Rear I O Board Rear Input Output Board Auxiliary interface board which is connected to the cPCI backplane rear connector
58. ire or electric shock hazard If the product contains socketed components they should be inspected to make sure they are seated fully in their sockets CPC504 User Manual 7 2011 Fastwel Ver 002a E Fastwel Ley CPC504 Handling In performing all necessary installation and application operations please follow only the instructions supplied by the present manual In order to keep Fastwel s warranty you must not change or modify this product in any way other than specifically approved by Fastwel or described in this manual Technical characteristics of the systems in which this product is installed such as operating temperature ranges and power supply parameters should conform to the requirements stated by this document Retain all the original packaging you will need it to pack the product for shipping in warranty cases or for safe storage Please pack the product for transportation in the way it was packed by the supplier When handling the product please remember that the module its components and connectors require delicate care Always keep in mind the ESD sensitivity of the product Three Year Warranty Fastwel Co Ltd Fastwel warrants that its standard hardware products will be free from defects in materials and workmanship under normal use and service for the currently established warranty period Fastwel s only responsibility under this warranty is at its option to replace or repair any defective compo
59. l does not assume responsibility for any damage to the CPC504 module or other system parts resulting from overheating of the central processor it is important to ensure that the CPC504 operational environment parameters conform to the thermal requirements described in this Manual 6 2 System Power The Intel Core 2 Duo processor family require special characteristics of the power supply unit and the backplane The CPC504 module itself has been designed to provide best possible power supply for each system unit However in order to guarantee reliable and faultless operation the following requirements must be taken into account Absolute maximum input voltages presented in the table below must not be exceeded to guarantee that the CPC504 is not damaged The ranges for the different input power voltages within which the module is functional are also presented Table 6 1 DC Input Voltage Ranges and Limits 3 3 3 6 3 135 to 3 465 5 5 5 4 75 to 5 25 Power supplies to be used with the CPC504 should comply with these requirements Only backplanes which have two power layers for each of the 3 3V and the 5V supply voltage are recommended for CPC504 Input power connections to the backplane itself should provide minimum power loss Avoid using long input lines low carrying capacity cables high resistance connections To select the appropriate system power supply it is necessary to consider the CPC504 own power consumption
60. mory shared with system CRT displays support with resolutions of up to 2048x1536 32 bits at 75 Hz Dual SDVO support front rear output capability VGA two DVI D interfaces External graphics controller support via x16 PCI E Secure Digital card socket Up to 4 GB soldered NAND flash disk with IDE interface SATA interface 3 ports SATA and SATA Il support Gigabit Ethernet interfaces Two PCI E controllers 10 100 1000 Mbps Front rear switchable USB 1 1 and 2 0 support up to five devices Six serial ports via LPC interface Parallel port IEEE1284 ECP EPP available at MIC584 HD audio interface Line In Line Out Headphones Out and Mic In PS 2 keyboard and mouse interface Real time clock with battery backup batteryless operation capability Self control and monitoring system LED indicators Programmable ejector switch Phoenix BIOS Available either on the CPC504 on Rear I O or on mezzanine modules CPC504 User Manual 10 2011 Fastwel Ver 002a E Introduction Fastwel EN CPC504 1 2 CPC504 Versions At the present time the module is offered in flexible configuration The options include different processors the size of soldered system memory and other options described in this section Versions 03 and 04 of CPC504 are supplied with MIC588 expansion module dual DVI D interface installed to the left of processor module All variants except C2D2 2 are available in
61. mple System memory RAM2048 2048 MB soldered DDR2 SDRAM RAM4096 4096 MB soldered DDR2 SDRAM Heatsinks RI Low profile 4HP R2 High profile 8HP Operating temperature range C Commercial 0 C to 70 C Industrial 40 C to 85 C Other options Coating COATED Protective Coating Operating System XPE Windows XP Embedded LNX Linux 2 6 CPC504 01 CS1 0 RAM2048 R1 C 1 3 3U CompactPCI processor module 4096 MB soldered NAND flash disk Intel Celeron ULV 573 CPU 512 KB L2 cache 1 0 GHz 533 MHz FSB 2048 MB soldered DDR2 SDRAM Low profile heatsink Commercial operating temperature range 0 C to 70 C CPC504 Diagrams The diagrams in this section give visual information about the CPC504 module design its appearance connectors and components layout The diagrams may not reflect insignificant differences between the CPC504 versions v CPC504 User Manual 12 2011 Fastwel Ver 002a E Introduction Fastwel Lee CPC504 1 3 1 Figure 1 1 2 HDD SD LED P1 GP LEDs J Wi ST Po Switch C Block Diagram CPC504 Block Diagram Mezzanine Connector J1 PCI Express x16 Sie SS tS CK 410 amp Hardware SS Clocking Monitor Soldered Intel PERI Core 2 Duo SDRAM Processor up to 4 GB
62. nent part of such products free of charge Fastwel neither assumes nor authorizes any other liability in connection with the sale installation or use of its products Fastwel shall have no liability for direct or consequential damages of any kind arising out of sale delay in delivery installation or use of its products If a product should fail through Fastwel s fault during the warranty period it will be repaired free of charge For out of warranty repairs the customer will be invoiced for repair charges at current standard labor and materials rates Warranty period for Fastwel products is 36 months since the date of purchase The warranty set forth above does not extend to and shall not apply to 1 Products including software which have been repaired or altered by other than Fastwel personnel unless Buyer has properly altered or repaired the products in accordance with procedures previously approved in writing by Fastwel 2 Products which have been subject to power supply reversal misuse neglect accident or improper installation Returning a product for repair 1 Apply to Fastwel company or to any of the Fastwel s official representatives for the Product Return Authorization 2 Attach a failure inspection report with a product to be returned in the form accepted by customer with a description of the failure circumstances and symptoms 3 Carefully package the product in the antistatic bag in which the product had b
63. nitor This is a Intel VideoBIOS particularity 5 1 2 Booting from USB To boot from a device connected to USB Connect the device to boot from to a USB port The appropriate USB controller should be enabled n Enter the PhoenixBIOS Setup program n Find this USB device at the Boot page and use buttons to move it in order to change its boot priority n Save changes and reboot the module To get the on line help about the details of BIOS Setup program operation please apply to the screen tips and the integrated help system CPC504 User Manual 58 2011 Fastwel Ver 002a E Thermal and Power Issues Fastwel Ley CPC504 6 Thermal and Power Issues 6 1 Temperature Control Intensive operation of Intel Core 2 Duo processor in harsh environment requires a special technology to keep the processor s die temperature within allowed limits The following sections provide system integrators with the information which will help to meet thermal requirements when developing systems based on CPC504 6 1 1 Passive Regulation The thermal management concept of CPC504 module includes several separate but correlated functions Their main purpose is to protect the processor from overheating and reduce its power consumption Dedicated thermal control subsystem allows the processor to operate within safe temperature range without the need for special software or interrupt handling 1 Catastrophic Shutdown Detector technol
64. nout 1 Red Red video signal output Out 2 Green Green video signal output Out 3 Blue Blue video signal output Out 9 VCC Power 5V DC 200 mA Out 12 DDCdata IC data In Out 13 Hsync Horizontal sync TTL out 14 Vsync Vertical sync TTL out 15 DDCclk IC clock Out 5 6 7 8 10 GND Signal ground 4 11 Free reserved CPC504 User Manual 48 Fastwel Detailed Description Fastwel Ley CPC504 2 3 6 Serial Interfaces RS232 and RS485 Serial interfaces are available only on MIC584 interface expansion module There are six serial ports available via MIC584 connectors E COM1 RS232 9 pin D Sub front panel connector E COM2 COM4 RS232 three IDC2 10 onboard connectors XP11 XP13 m COM5 COM6 RS485 one IDC2 10 onboard connector XP7 All COM ports are fully compatible with the 16C550 controller and include a complete set of handshaking and modem control signals maskable interrupt generation and data transfer of up to 460 8 Kb s 2 3 7 Parallel Port Interface Standard parallel port IEEE1284 SPP ECP EPP is available only on MIC584 mezzanine module 2 3 8 Gigabit Ethernet The CPC504 board includes two 10Base T 100Base TX 1000Base T Ethernet ports based on Intel 82574L Gigabit Ethernet PCI E bus controllers The Intel 82574L Gigabit Ethernet controller architecture combines high performance and low power consumption The controller s features includ
65. oenix BIOS Setup Fastwel Ley CPC504 5 Phoenix BIOS Setup The Phoenix BIOS in your SBC is an adapted version of a standard BIOS for IBM PC AT compatible personal computers equipped with Intel x86 and compatible processors The BIOS provides low level support for the central processing memory and I O system units With the help of BIOS Setup program you can modify the BIOS configuration parameters and control the special features of your module The Setup program is started by pressing the F2 key and offers a convenient menu interface to modify basic system configuration settings and switching between the subsystems operation modes These settings are stored in a dedicated battery backed memory CMOS RAM that keeps the information when the power is switched off For increased security the CMOS data and some of the service parameters are stored also in a nonvolatile serial EEPROM memory This allows to restore the critical data in emergency cases after battery failure 5 1 Boot Details 5 1 1 Booting without a Monitor Keyboard or Mouse To boot without a monitor keyboard or mouse set the item POST Errors to Disabled at the page Main in PhoenixBIOS Setup program This setting is a default one Note If the module was booted without a connected monitor the display will be empty even if a monitor is connected later during operation To get the correct display output it is necessary to reboot the module with a connected mo
66. ogy allows to automatically switch the processor off when the processor die temperature reaches approximately 125 C due to for example the cooling system failure The catastrophic shutdown detector is based on an internal thermal diode used to detect internal core processor temperature This function is always active to protect the processor in any case Processor execution is halted until the next reset cycle Once this function is activated the system does not return to the normal operation mode automatically it is necessary to reset the BIOS settings and to cold restart the system 2 The Intel Core 2 Duo processor supports the Enhanced Intel SpeedStep technology It allows to dynamically switch the processor core voltage and frequency without resetting the system when the processor core temperature reaches 100 C For example the Core 2 Duo L7500 processor operating at 1 6 GHz and 1 2 V can be switched down to 800 MHz and 0 95 V thus reducing the processor power dissipation 4 External thermal monitor LM87 gathers information about the processor and board surface temperatures from two sensors One additional thermal monitor is used to watch the memory modules temperature This information may then be requested by a program to undertake the appropriate actions Recommendations Generally there is no need to enable the Thermal Management functions if the module is operated in a optimally designed environment with sufficient air flow
67. ompactPCI connector pinouts appear on the following pages CPC504 User Manual 42 2011 Fastwel Ver 002a E Detailed Description Fastwel Lee CPC504 2 3 1 2 CompactPCI Connectors J1 and J2 Pinouts CPC504 is equipped with two 2x2 mm pitch female CompactPCI bus connectors J1 J6 and J2 J3 Table 2 3 CompactPCI Bus Connector J1 J6 System Slot Pinout 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V LNG_VIO AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 LNG_5V AD 2 GND 22 GND AD 7 GND LNG_3 3V AD 6 AD 5 GND 21 GND 3 3V AD 9 AD 8 M66EN C BE 0 GND 20 GND AD 12 GND VIO AD 11 AD 10 GND 19 GND 3 3V AD 15 AD 14 LNG_GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA LNG_GND PERR GND 16 GND DEVSEL GND VIO STOP LOCK GND 15 GND 3 3V FRAME IRDY SHRT_GND TRDY GND 14 GND GND 13 GND Key Area GND 12 GND GND 11 GND AD 18 AD 17 AD 16 LNG_GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 SHRT_GND AD 23 LNG_GND AD 22 GND 8 GND AD 26 GND VIO AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 LNG_GND AD 27 GND 6 GND REQO GND LNG_3 3V CLKO AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST LNG_GND GNTO GND 4 GND IPMB_PWR HEALTHY LNG_VIO INTP INTS GND 3 GND INTA INTB INTC LNG_5V INTD GND 2 GND TCK 5V T
68. or Reset signal is generated It is possible to set the timeout period from 0 to 512 seconds with increments of 30 52 us by changing the decimal value in BIOS Setup By default without prior initialization the watchdog timeout period is set to maximum that is 512 seconds The equation below can be used to calculate the timeout Two in us as a function of the decimal value in the Timer Initial Value Register Kwp Two us Kwo 10 2 For example decimal value 1 of Kwp 000001h corresponds to the timeout of 30 52 us and Kwp 16777215 FFFFFFh to 512 seconds Strobing of the watchdog timer is performed in one of the following ways m Writing any value in the Timer Current Value Register Writing any value in 80h port this mode is enabled in Timer Init Register P Writing to or reading from two windows The address is set in appropriate Window Base Address registers the address mask is set in Windows 1 amp 2 Address mask register the mode is set in Timer Init Register The Window size is from 1 to 16 bytes depending on the value in the Mask register Access to Watchdog Registers The unit s configuration is based on Plug and Play architecture Access to watchdog registers is available via standard I O registers index and data in configuration mode CONFIG PORT 302h Write INDEX PORT 302h Read Write DATA PORT 303h Read Write Configuration Mode To enter the configuration mode write lt 46h gt lt 57h gt
69. outed from CPC504 via XS6 connector Parallel port IEEE 1284 SMSC SCH3116 Super I O Standard mode Bi directional SPP Enhanced mode EPP v 1 7 and v 1 9 High speed mode ECP IEEE 1284 Onboard connector IDC2 26 PGD interface SMSC SCH3116 Super I O Standard 6 contact Mini DIN front panel connector Y cable included in supplied set for connection of PS 2 keyboard and mouse MB Six serial ports 6x16C550 UART SMSC SCH3116 Super I O COMI non isolated RS 232 port D Sub9M front panel connector COM2 COM3 COMA non isolated RS 232 ports IDC2 10 onboard connectors COM5 COME non isolated RS 485 ports IDC2 10 onboard connector Serial ATA interface 2 channels Connection of up to two external SATA devices using standard cables included in supplied set One channel can be used for connection of 1 8 SATA HDD or SSD mounted onboard using KIB584 adapter plate Two onboard connectors Additional features The PCB is reduced to provide better cooling of CPC504 module Does not require forced air cooling MTBF not less than 700000 hours m Dimensions Reduced 3U cPCI 88 3 mm x 100 mm without front panel 4HP E Power 3 3V 45 1A 45 V 5 2A Powered from CPC504 CPC504 User Manual 68 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 4 MIC584 Block Diagram Figure 7 7 CPC504 Block Diagram COMI RS232 S
70. over the right button is a programmable switch that can be used to initialize the system manually CPC504 User Manual 29 2011 Fastwel Ver 002a E Introduction Fastwel Ley CPC504 1 4 Technical Characteristics 1 4 1 Processor Memory and Chipset CPU CPC504 supports the following Intel processors Intel Celeron ULV 573 512 KB 1 00 GHz 533 MHz 10W Intel Core 2 Duo L7500 4 MB 1 6 GHz 800 MHz 17W Intel Core 2 Duo T7500 4 MB 2 2 GHz 800 MHz 35 W System Memory Chipset Up to 4 GB of soldered DDR2 SDRAM w o ECC DDR2 667 standard PC2 5300 I O bus clock 333 MHz Dual channel mode enabled GMCH Intel 82965GME Integrated dual channel DDR2 memory controller FSB interface at 800 MHz Integrated high performance graphics controller with analog and digital output Support for external graphics controller with PCI Express x16 interface Intel ICH8M I O Controller Hub PCI Rev 2 2 compliant with support for 33 MHz 32 bit PCI bus Configurable PCI Express interface Serial ATA Il controller 3 channels Integrated IDE controller Ultra ATA100 one channel USB 2 0 host interface 10 ports Low Pin Count LPC interface HD audio interface SPI bus support Integrated RTC with CMOS Power management controller with ACPI and APM support System Management Bus Firmware Hub FWH interface support Enhanced DMA controller interrupt controller and timer Additional timers CPC504 User Manual 2
71. r 002a E Detailed Description Fastwel Ley CPC504 2 Detailed Description 2 1 Processor Memory and Chipset 2 1 1 Processor CPC504 can be equipped with the following Intel processors Intel Celeron ULV 573 512 KB 1 0 GHz 533 MHz 10W Intel Core 2 Duo L7500 4 MB 1 6 GHz 800 MHz 17W Intel Core 2 Duo T7500 4 MB 2 2 GHz 800 MHz 35 W Supported features of Core 2 Duo CPUs are Intel Core Microarchitecture Dual Execution Cores Intel EM64T SSE2 SSE3 SSSE3 Advanced Transfer Cache Architecture Intel Dynamic Acceleration Intel Thermal monitor with Adaptive Thermal Monitor 2 enhancement Manufactured on 65 nm process Enhanced Intel Speedstep Technology Dynamic FSB Frequency Switching Intel Virtualization Technology Execute Disable Bit Intel Celeron ULV 573 processor offers low TDP and provides high performance to power dissipation ratio Having single core it has the same microarchitecture and supports virtually the same main features The CPU is soldered to provide excellent shock and vibration stability 2 1 2 System Memory Total capacity of the soldered DDR2 SDRAM chips can be up to 4 GB The installed memory is DDR2 667 PC2 5300 compliant and supports PC SPD Serial Presence Detect Specification Dual channel mode is supported CPC504 User Manual 30 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 2 1 3 Intel Chipset The chipset consists o
72. ress 7 0 Window2_Base_Adress 15 8 CPC504 User Manual 36 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 Windows 1 amp 2 address mask register Index F6h Write Read Ha D Bits 3 0 Window 1 address mask Write Read 3 0 mundow2 MASKED Bits 3 0 Window 2 address mask WDT Controller UO Registers Timer Current Value Register 23 0 Base 0h Write Read Bits 7 0 of the current timer value 7 0 Timer_Current_Value 7 0 Base 1h Write Read Bits 15 8 of the current timer value 7 0 Timer_Current_Value 15 8 Base 2h Write Read Bits 23 16 of the current timer value 7 0 Timer_Current_Value 23 16 Timer Initial Value Register 23 0 Base 3h Write Read Bits 7 0 of the initial timer value 7 0 Timer_Initial_Value 7 0 Base 4h Write Read Bits 15 8 of the initial timer value 7 0 Timer_Initial_Value 15 8 Base 5h Write Read Bits 23 16 of the initial timer value 7 0 Timer_Initial_Value 23 16 CPC504 User Manual 37 2011 Fastwel Ver 002a E Detailed Description Fastwel LE CPC504 Status Register Base 6h 7 3 Reserved Write Read 2 STM Second timeout flag It is set to 1 if TMF 1 and RSTE 1 Cleared by writing 1 into this bit Read 1 SME SMI enabled on timeout flag It is set to 1 if SMI mode is enabled in Primary interrupt s
73. ront panel they are used for connection of headphones Phone and a microphone Mic Figure 7 12 LINE_IN XP5 and LINE_OUT XP6 Connectors EC MIC584 also has two 3 pin onboard connectors UNE IN XP5 a ae 1 and LINE_OUT XP6 Their pinouts are presented in the tables below Table 7 7 LINE_IN XP5 Connector Pinout 1 LEFT Left channel Input In 2 GND Ground 3 RIGHT Right channel Input In CPC504 User Manual 73 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Lee CPC504 Table 7 8 UNE OUT XP6 Connector Pinout 1 LEFT Left channel output Out 2 GND Ground 3 RIGHT Right channel output Out 7 5 2 5 L3 and L4 LEDs There are two programmable LED indicators L3 and L4 on the front panel of MIC584 7 5 2 6 LPT Interface Parallel port interface of MIC584 is realized in SMSC SCH3116 Super I O chip and is routed to 2 row 26 pin onboard LPT connector XP2 For connection of a standard parallel cable an adaptor 25 is needed Figure 7 13 LPT Connector XP2 2 o kel o o le oO e Oo fe e 1 o o D o o o o e o o Table 7 9 LPT Connector Pinout 26 LPT contacts numbering the pinout is in the table below 1 STROBE Out 14 GND 2 AUTOFD Out 15 PD6 In Out 3 PDO In Out 16 GND 4 ERROR In 17 PD7 In Out 5 PD
74. s PWM output Pulse Width Modulation Cooling fan control technique ESD Electrostatically Sensitive Device Electrostatic Discharge ACPI Advanced Configuration and Power Interface POST Power On Self Test cPCl CompactPCI Industrial automation systems standard EOS Electrical Overstress MDI Media Dependent Interface Interface with connection type automatical detection CPC504 User Manual Fastwel 82 2011 Ver 002a E
75. t of CPC504 J12 supports SD cards with operating voltage of 3 3 V Note XK SD cards may be connected or disconnected while the system power is on Carefully slide in the correctly oriented card and gently press to engage the contacts completely Please remember that the heatsink may be hot after operation Note It is recommended to use SD cards which has been initialized and formatted in this module Br 3 4 3 Battery Replacement The lithium battery must be replaced with Panasonic BR2032 or a battery with similar characteristics The expected life of a 190 mAh battery in case of operation for 8 hours a day at 30 C is about 5 years However this typical value may vary because battery life depends on the operating temperature and the shutdown time of the system in which the battery is installed Note It is recommended to replace the battery after approximately 4 years to be sure it is operational Replacing the battery make sure the polarity is correct up i Important Dispose of used batteries according to the local regulations CPC504 User Manual 55 2011 Fastwel Ver 002a E Installation Fastwel Ley CPC504 3 5 Installation of MIC584 Mezzanine Expansion Module Figure 3 1 Fixing of MIC584 on CPC504 A B TO III 1 7 b Il L L 0 ge H 0 l 0 N S IO O o p D L D J2 C To install MIC584 mezzanine expansion module on CPC504 do the following
76. to requests from applications allocating the required amount of video memory The Intel 965GME graphics driver is allowed to request up to 384 MB of system memory When not needed by the graphics subsystem the memory is freed up for other applications Thus memory usage is balanced for optimal graphics and system memory performance To support legacy VGA devices the internal video controller needs at least 1 MB of system memory Thus the reported system memory size is always 1 MB less than available amount of physical memory 2 3 5 2 Supported Resolutions The integrated 400 MHz RAMDAC of the 965GME chipset allows direct connection of a progressive scan analog monitor with a resolution of up to 2048 x 1536 at 75 Hz The supported resolution depends on the color depth and on the vertical scanning frequency as illustrated in the table below CPC504 User Manual 47 2011 Fastwel Ver 002a E Detailed Description Fastwel Lee Table 2 7 Partial List of Supported Display Modes 640 x 480 800 x 600 1024 x 768 1280 x 1024 1600 x 1200 1920 x 1440 2048 x 1536 2 3 5 3 CRT Interface and Connector Figure 2 4 SVGA J45 Front Panel Connector The 15 pin female D Sub connector J45 on CPC504 front panel is used to connect a CRT monitor to the CPC504 module Its pinout is in the table below Table 2 8 SVGA J45 Front Panel Connector Pi
77. uper I O Coli PS 2 Front Panel Mezzanine Connector 2xUSB LPC 2xSATA II HD Link SATA Port 1 St mei N o F Interfaces Audio HD Link Line Out Codec AD1986 Audio Line In CPC504 User Manual 69 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 5 7 5 1 7 5 1 1 MIC584 Interfaces MIC584 Interfaces List Front Panel 4HP Interfaces The following interfaces are available at the MIC584 front panel 7 5 1 2 COM1 RS232 interface 9 pin D Sub connector Two USB 2 0 4 contact sockets USB3 and USB4 type A Two user programmable LEDs L3 and L4 PS 2 interface 6 contact MiniDIN connector for mouse and or keyboard Audio Interface Phone output to headphones Mic input from microphone Internal Interfaces The following interfaces are available via the on board connectors Parallel interface LPT connector 26 pin 2 row 2 54 mm pitch COM2 COM4 RS232 interfaces IDC connectors 10 pin 2 row 2 54 mm XP11 XP 13 COM5 COM6 RS485 interfaces IDC connector 10 pin 2 row 2 54 mm XP7 Serial ATA interface two 7 contact standard connectors Audio interface Line In 3 pin XP5 and Line Out 8 pin XP6 CPC504 User Manual 70 2011 Fastwel Ver 002a E MIC584 Mezzanine Expansion Module Fastwel Ley CPC504 7 5 2 MIC584 Interfaces Detailed Description 7 5 2 1 Serial Interfaces
78. use an external hub e One USB device may be connected to each port To connect more The USB power supply is protected by a self resettable 500 mA fuse Table 2 6 USB1 and USB2 Pinouts CPC504 Front Panel 1 VCC VCC signal 2 UVO Differential USB 3 UV0 Differential USB 4 GND GND signal CPC504 User Manual 46 2011 Fastwel Ver 002a E Detailed Description Fastwel Ley CPC504 2 3 5 Graphics Controller A highly integrated 2D 3D graphics accelerator is included in the 965GME chipset The internal graphics controller provides interfaces to a standard analog monitor SVGA connector on CPC504 front panel or and to a digital displays External video adapters with PCI Express x16 interface are supported Integrated 2D 3D Graphics features 2D accelerator Up to 384 MB video memory shared with system Support for RGB monitors with resolutions up to 2048x1536 32 bit at 75 Hz Dual DVI support possibility to switch graphics output to rear panel Support for external video adapters with PCI E x16 interface Support for DirectX 10 0 Open GL 2 0 Shader Model 4 0 i Core frequency up to 333 MHz Rendering frequency up to 500 MHz 2 3 5 1 DVM Technology The 965GME chipset supports the Dynamic Video Memory Technology DVMT This technology provides use of all available memory in the most efficient way for maximum graphics performance DVMT dynamically responds
79. work data 2 3 9 Figure 2 6 2 3 10 Socket for Secure Digital Card SD Card Socket LED Indicators To enable usage of SD memory cards CPC504 has a Secure Digital card socket J12 on board SD interface is connected to an internal USB 2 0 port via SMSC USB2241 controller SD cards with maximum capacity of 16 GB are supported Two LED indicators L1 and L2 are located on the CPC504 front panel Table 2 10 L1 and L2 Front Panel Indicators L1 Activity indicator Yellow SD memory card activity Red SATA or Flash drive activity L2 CPC504 boot process Green fast blinking 8 Hz The module is powered The system is monitoring activated Green slowly blinking 1 Hz POST Power On Self Test in process Green steady light OS is being loaded Red steady light Activation error wrong slot incomplete insertion of the module power supply failure System state indication Red fast blinking 8 Hz Clear CMOS mode activated pending Programmable switch release Orange steady light S5 soft off mode The active mode is enabled by momentary pressing on Programmable switch Orange slowly blinking 0 5 Hz S3 Suspend To RAM mode The active mode is enabled by momentary pressing on Programmable switch Programmed by user After initialization and OS loading L2 indicator can be used as programmable LED L2 modes programming is described below