Home

User`s Manual (EN) - Avitech International Corporation

image

Contents

1. Cancel 3 Save and exit the Galaxy program this can also be done once all the parameters have been configured 51 4 By default all windows are enabled for the TSL protocol This can be changed for an individual window on a group basis or at the system level by clicking Settings gt System Parameter fae Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select EAU Special Screen Layout Help E Set Output Mode v Flashing Window Border Image2 Reconnect Serial Port System Parameter Image Group Parameter gt Module Parameter gt Import txt Export txt gt 5 Click All TSL and then select ON OFF Return Group Index to Default One Module Per Group Save System Files To Flash 4ll Meters gt All Labels All Clocks gt on OFF Module Cascade Series Advanced Clear Tally Status Setup Module Speaker ID For an Entire Group 1 Select Settings gt Group Parameter gt TSL 52 2 Ensure that Enable is selected with checkmark If it is unchecked only static labels will be displayed Display Address Modes Fixed Brightness TSL Only Allow Both Static amp Dynamic Display First 8 Characters C Display All 16 Characters Cancel 3 Specify the Display Address ranges from 0 to 126 The address should match the TSL controller configured address corresponding to the router output feeding the corresponding Avitech input 4 Ifyou want to disp
2. Linel C Line2 C Line3 C Lines C LineS C Line P AllLine Select Color 79 Safe Area Upon right clicking on a particular window select Safe Area and the following screen appear Safe Area M Enable ua 12 Rea 87 Cancel Update The following should be noted when setting the safe area e Luminance is reduced outside the safe area e Enable can be enabled disabled for each source window By using the slider freely adjust the horizontal Left and Right and vertical Top and Bottom markers 80 e Display 4 3 markers fixed 4 3 markers vertical yellow lines delineates the 4 3 area in a 16 9 window Underscan Upon right clicking a particular window select Underscan and the following screen appears Refer to a previous section for details on setting the underscan parameters M Is UnderScan ja Left J6 a C gt UnderScan x Width 0 Ki Bi Te fo a1 gt i Height jo Ki EA Cancel Default 81 Set Alarm Upon right clicking a particular window select Set Alarm and the following screen appears Refer to a previous section for details on setting the Alarm Properties Alarm Properties Process JV Module Alarm Switch Process Alarm Switch Borders All Process Response time joss _ Signal In or Abnormal to Normal I Audio Alarm Switch T Red J Flash oss I Video Alarm Switch l Red J Flash Signal Out or Nor
3. Examples ZB Format Function Examples ZC Format Function Description ZA 010900 2 1 Set group module 9 to a 2x2 map position 1 2 3 4 quad ZA 010000 2 1 Set group 1 s all modules to quad ZA 010202 3 2 Place window 010202 to a 3x3 map position 2 ZA 010200 6 13 Place group 1 module 2 to a 6x6 map position 13 14 15 16 ZA 000000 Automatically arrange all groups windows to the optimum size and position ZB GGMMPP B order L abel 1 on 0 off to turn on off blinking of border or label ZB GGMMPP L 0 GGMMPP turn blinking label off ZB GGMMPP B 1 GGMMPP turn blinking border on ZC GGMMPP B order L abel RRRGGGBBB red ratio 000 255 green ratio 000 255 blue ratio 000 255 NoDimColor to set the border of the window with without 3D effect and the label s background color B order to signify the border of the window L abel to signify the label s background color NoDimColor to signify the border s 3D effect You can add NoDimColor to remove the border s 3D effect Just enter NDC to signify NoDimColor 103 Examples ZE Format Function Examples ZF Format Function Examples ZI Format Function ZC 010101 B 000255000 sets the border color of group 1 module 1 window 1 as green with 3D effect ZC 020202 B 255000000 ndc sets the border color of group 2 module 2 window 2 as red but without 3D effect ZC 030303 L 00000
4. Export txt 22 Reconnect Network Serial Port When you have unplugged the IP cable and re connected it click Reconnect Network to continue the configuration process Or when using the serial cable click Reconnect Serial Port instead fas Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select EA Special Screen Layout Help Ei Set Output Mode v Flashing Window Border Image iN Image3 Reconnect Serial Port System Parameter Image 211 Image2 Group Parameter Module Parameter Import txt Export txt mage4 23 System Parameter The following setup affects all the modules of all the groups Upon clicking System Parameter the menu appears as shown next Return Group Index to Default One Module Per Group Save System Files To Flash All Meters All Labels All Clocks All TSL Yv v v Module Cascade Series Advanced Clear Tally Status Mk p rt Setup Module Speaker ID 24 Group Parameter The following setup affects all the modules in the selected group only Upon clicking Group Parameter the menu appears as shown next Group Reset Meter Label Border Tally Slarm Clock UnderScan COM TSL Aspect Auto Detect gt Output Timing gt YGA to Background gt fi 19 k Window Size gt Fat gt Set Default Layout 25 Module Parameter The following setup affects the selected module only Upon clicking Module Parameter th
5. 800 x 600 4 2 1280 x 768 N SONY LMD230 1280 x 768 N SONY LMD172 1280 x 768 N SONY LMD322 4 4 2 2 A A A x 1400 x 1050 3 JVC ewo a _ 1280 x 800 Apple monitor 2 0 9 8 3 6 9 1 8 7 107 Examples ZN Format Function Examples 252 VESA timing 253 color graphic card timing 254 frame lock timing 255 normal timing ZM 010000 10 sets all the modules in group 1 to display at 16001200 resolution at 60 Hz vertical frequency and automatically arrange all windows to the optimum size and position ZM 000000 9 NA sets all the modules in all the groups to have a 12801024 resolution at 60 Hz vertical frequency with no automatic arrangement For turning on off various options ZN GGMMPP option A larm B order C lock control D isplay closed caption E xtend label background F PGA selection 0 digital clock 1 analog clock L abel M eter N eedle of clock R atio aspect S afe area V ideo format display W indow 1 on 0 off to turn on off various options ZN GGMM99 W 0 turns GGMM clock off ZN GGMMPP B 1 turns GGMMPP border on ZN GGMMPP B 1 turns GGMMPP border on ZN GGMMPP F 0 selects mainboard FPGA 0 108 ZO Format Function Examples ZP Format Function Description For initializing the audio source ZO GGMMPP I nitialize 1 4 Lgroup AES Rgroup 60 frequency is 60 Hz or else it is 59 94 Hz 1 PPM
6. Extended Warranty Options 0 ccccceeeeeeeeeteeeeeeeeneeeeeeneeeeetieeeeetieeeeeeaa v Services and Repairs Outside the Warranty Period ceeseeeeeeeeeeees v Regulatory Information vasniicditenduecessisestsineebivendeiestsvncedienawsnsietineeineaaainens vi Federal Communications Commission FCC Statement 0 eee vi European Union CE Marking and Compliance Notices 08 vii Statements of Compliance cece ceecseeeceeeeeeeeceeneeceeeeeeesecencnaneeeeeeess vii Australia and New Zealand C Tick Marking and Compliance Notice viii Statement of Compliance 20 eee eeeeeceece eee eeeeeeeeeeeeeeeeeeeeseteenneceeeeess viii Prefa CE eea a aaa Ama aaa sag e aaa aaa a a aa A EE Ea Aaea Ee A e NEE apiapi ix Welcome ii cctd ieee eddie lai ee ix About this Manual ccsceceinuindicce eae ee x 1 Getting Started ocius enanitos iaeia 1 I Package Contents rrii siaina ai aiian 1 12 Product FoatutroS ecrini iE A 2 SPECICATION css5s dearenniatenrsacdvtasysancaeaanendiaganadverseuaneaaeeaadmenmidiees 3 Operating Feature esiin EE EARNE RENA 4 1 3 Identifying the Front Hardware Component eeeeeeeeeeeeeeeeeeeeeeeeee 4 1 4 Identifying the Rear Hardware Components n s 5 1 5 Getting Your MCC 8004 Series Ready for Use 6 Basic Hardware Connections cccccceeeceeeeeeeeeeeseeeneeeeseenaeeeeneanees 6 CASCACING cceceeeeeeeceeeeeeeeeeeeeeeteeeaeeeeeeeaeeeseeaeeeeseeaeeeseenaeeeeeen
7. Position Fine Adjustment Size Fine Adjustment Check Audio Set Com 88 2 Select a saved file then click OK to load the preset Load File Directory C MAvitech VE Bl x v Flash ga ga gm ga Group Group Group Group Group AR GP1 AILGP1 Cascade GP1 Features GP1 Quad 169 GP1 Quad 43 GP1 ga Group Rainier 4U1 v File Name Display Resolution 1080p 50H2 Update To Module Flash 89 Making Adjustments 1 Inthe Option menu click Adjustment Style Master MCC_8004_d dE dL dEL r COM m 01 y fs m Select ID or Add To Other Group 9 il we g sig to 5 is DENS TaS UG ts Gente 110 fe A A a Mute mnt Sub ID co i a to tae Image Window amp Label Switch WoL wW L Bj Imaget Bly I Image2 1 IV I Image 5j M Iv Image4 T PF Images E I T Images E F T Image F T Image Load File Save File Fader Control Image Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com 90 2 The following screen appears Image Adjustment r Select Image Window c pic sic alc sic mic mic mic Parameters Brightness EJ aj gt Sharpness fo Erl Saturation jes 4 E Cb_Offset Ki Contrast fee 4 gt Ci Offset m a He fo 4 gt f HD p HEnhGan d 2 venhthesh HEnhThesh d gt vema M HEGan d gt Env 4 HLE Thresh F d HDE Gan d HDE Thresh J Ki r Color Key Hee CA C Rhed
8. 2 VU ballistics For setting the audio output ZO GGMMPP 1 on 0 off channel 1 stereo 2 mono left 3 mono right sound to initialize the audio source as well as set the audio output ZO GGMMPP 1 AES 60 1 sets GGMMPP Lgroup 1 Rgroup AES 60 Hz PPM ZO 000000 0 turns the audio off ZO 020100 1 turns group 2 module 1 audio on ZO 000203 1 4 turns the audio on for all groups in module 2 window 3 to channel 4 ZO 020201 123 sets group 2 module 2 window 1 channel 2 to output audio on mono right ZP GGMMPP L oad S ave filename GP ZP GGMM This command only works in HyperTerminal ACP does not support this format load a previously saved preset or save current layout to a preset If the filename includes space s use double quotation marks to signify the complete filename If the filename is not specified when saving the file system will backup the file into flash memory 109 Examples ZR Format Function Examples ZT Format Function ZP 000000 L stage1 sets all the modules in all the groups to load the previously saved stage preset file ZP 020000 S file2 GP2 saves the current layout of all modules in group 2 to a preset file file2 GP2 ZP 000000 S saves the file of all modules in all the groups into flash memory ZP 000000 L Latest load the latest saved file from flash memory ZP 0000 list master presets ACP does not support this com
9. Audio Alarm Switch adjust the Signal Type s Font Color and B G background Color for alarm in the group You can also lock the video alarm Alarm Properties Group JV Module Alarm Switch IV Process Alarm Switch Borders All Process Response time IV Video Alarm Switch I Red T Flash os Signal In or Abnormal to Normal IZ Audio Alarm Switch I Red T Flash oss Signal Out or Normal to Abnormal p gagi far Alarm Lock ja ja I Video Black Threshold Voltage Ki gt Area IV Signal Type Signal Type Font Color Signal Type BG Color E Cancel For an Individual Window To set the alarm properties for an individual window right click the mouse on the window and select Set Alarm e Module Process Alarm Switch to turn on the alarm setting make sure that both options are enabled with checkmark 43 e Video Audio Alarm Switch to turn on off the no video signal You may set the image border to be Red or to Flash as warning e GPO to assign a GPO contact closure to alarm so that the alarm creates a voltage supports up to 5 V on the contact when it is triggered e All Process Response Time to set the no video alarm response time from 0 23 to 23 seconds e Disable No Motion Alarm to disable the alarm that is triggered when no motion is detected e Alarm Lock once the signal gets lost but re gains it back afterwards the warning will st
10. Display Address Modes J Fixed Brightness TSL Only C Allow Both Static amp Dynamic Display First 8 Characters C Display All 16 Characters Cancel 2 Specify the Display Address ranges from 0 to 126 The address should match the TSL controller configured address corresponding to the router output feeding the corresponding Avitech input 3 Ifyou want to display dynamic labels then click the radio button to select TSL Only If you want to display both the static and dynamic labels click the radio button to select Allow Both Static amp Dynamic 4 To display 8 or 16 dynamic characters in case the TSL implementation allows it click the radio button to select the corresponding options This concludes the TSL setup on the module level NTSC Black Level Allows you to set the NTSC black level by selecting 0 or 7 5 Default setting for the NTSC Black Level is 7 5 v 7 5 0 NOTE Only supports composite video input source 61 Special Screen Layout Menu Some special screen layouts are available for the MCC 8004 series namely layouts that are grayed out signify none availability for your particular configuration ile Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select Settings EAE ENGEMET Help eile Layout 1 Default 2x2 Layout 2 Default Others Image3 Layout 6 Briefing Image4 e Layout 1 Default 2x2 quad split mode e Layout 2 Default Others rows or columns o
11. MM Border GPI 2 VV D2 JF Label J Border Serial Tally 1 M LED1 W Label IV Border Tally 2 NV LED2 Label J Border Tally 3 M LED3 J Label J Border Cancel Update Tally 1 and 2 are triggered by GPIO while Tally 3 is triggered via serial communication 2 The settings that can be adjusted include Tally Color Label Border and Flash VGA to Background When the item VGA to Background under Group Parameter is set to On a checkmark appears on this item This allows you to alter the sequence of a particular cascading window that appears on the monitor display By default Window should appear on top of Window 2 but you can move it to be behind Window 2 into the background Click on the item to toggle between on off 58 GPI Definitions Eight positions can be found on the RJ 50 to GPI terminal block that are assignable to either activate Tally two per video input or to load presets but each pin can only be assigned to one task To assign the definition of each GPI perform the following steps 1 Upon clicking GPI Definitions the following screen appears GPI Definitions Pins Inputs rC Outputs rs Tallys Presets Clock Triggers Alarm Trigger Tally C Presetl Tally2 Preset2 Count Up Ta C Preset3 Tal C Preset4 C Count Down Preset Preset6 Pause Preset Preset8 C Next Preset Time zi Cancel 2 After you have finished assigning tasks to each GPI click OK to
12. Set Alarm Aspect Auto Detect TSL 73 Resizing Window To resize a single window to one of the preset sizes perform the following steps 1 Right click the mouse on a particular window and select Size followed by the desired preset size selection Full Screen 1 4 1 9 1 16 Select Source VCC 4xDVI gt 1 25 1 36 1 64 Set Aspect Ratio 4 3 Set Aspect Ratio 16 9 Check Signal Lock Aspect Ratio View 16 9 Image 4 3 Set Label Set Meter Set Border UnderScan Set Alarm Aspect Auto Detect NOTE This option is not available for the scaleable DVI input 2 Or manually resize a window by dragging the border of a window to the desired size Keep in mind that there is a scaling limitation for each window that limits the maximum scaleable size to 816465 pixels for NTSC video and 816x560 for PAL video 74 3 Alternatively you can use the Size Fine Adjustment menu to adjust each window on a pixel by pixel basis Keep in mind that the width increases in 16 pixel increments and the height in 1 pixel increments Style Master MCC_8004_d dE dL dEL COM F L rm Select ID or Add To Other Group iS i gh zs igs zl igs a 5 ig ig ig op 1 e e a ETE Size Fine Adjustment m Sub ID te ig a ig aig a Select Image Window rae ERE c 5 c 5 D T A 2 B C 5 M M Imaget VW Image2 comic BM M images MM I
13. When the following screen appears the checking result confirms that everything is normal If that is the case then click Cancel to exit restoring of preset s You may skip steps 3 and 4 Check Module Information Path C Avitech_VCC BackUp Browse J Forces Check result If the checking results shows an Abnormal report confirm if the backup Path is correct Then click Restore 67 If incorrect click Browse to select the correct location Then click OK to continue Select directory Current drive f gt C Current directory ex O System Volume Information windows DELL backup tool Documents and Settings tool Going32 Intel NVIDIA Program Files RECYCLER New Folder Delete Folder 3 Restore BackUp Path CMAvitech_VEC BackUp Browse C Use Saved File New Path Delete Path 4 Click OK when the next screen appears to restart the Galaxy program WARNING Restore Information Success Please Restart Galaxy 68 Converting Preset File to ASCII Format 1 Click Preset to ASCII When the following screen appears confirm if the Save Path is correct If incorrect click Browse to select the correct location Preset File to ASCII Save Path C Avitech_VCC Preset24SCll Browse rc Requirement M Border M Label V Position amp Size 2 Select the Requirements and then click Conversion 3 Click OK to exit Read Galaxy Information Cli
14. clicking on a particular window select Set Label and the following screen appear Refer to a previous section for details on setting the Label Properties Label Properties Process Align Left Center I BMP Label Total Characters 32 6 osp e Line 1 tie Linesa SS tines FontColor _ _B G Color MM size i gt miest BMP Label Font Type J Fill Background All Process J Text Transparency Switch Transparency PEO E F Cance Update NOTE When output resolution is set to 800x600 the label size can support up to two 36 pixels only 77 Setting the Meter Properties Allows you to change the audio meter properties Upon right clicking a particular window select Set Meter and the following screen appears Refer to a previous section for details on setting the Meter Properties Meter Properties Process Display Meter All Viv MYM Wii MNN IV MeterSW J Meter Outside H 128 L 0 Mea oe coe LPR LPR gyu 4 0 DBu H 230 L 25 Phase Meter Meter 2 Meter 3 Meter 4 Sound lA AGan Group 1 v Group 2 vi Width w E All Process r Transparency 78 Turning On Off the Border Allows you to change the properties for the border Upon right clicking on a particular window select Set Border and the following screen appear Refer to a previous section for details on setting the Border Properties Border Properties Process Enable
15. finalize the changes 59 NOTE e The RJ 50 to GPI terminal block adapter has eight positions that can each be used for setting Tally and loading presets By default the terminal block is used to turn on off the Tally for each window Position 1 GND turns on main Tally for window 1 Position 2 GND turns on secondary Tally for window 1 Position 3 GND turns on main Tally for window 2 Position 4 GND turns on secondary Tally for window 2 Position 5 GND turns on main Tally for window 3 Position 6 GND turns on secondary Tally for window 3 Position 7 GND turns on main Tally for window 4 Position 8 GND turns on secondary Tally for window 4 Preset Time By using the RJ 50 to GPI terminal block allows you to set the count up or count down the preset time Index 1 8 that can be recalled using GPIO Preset Time Index 1 m Index2 o Index 3 Index 4 Index 5 Index 6 Index 7 Index 8 Cancel ba i i i i a a o Bo fo jo D fo Jo Jao TSL NOTE Make sure that you have selected the TSL configuration on the previous setting under Group Parameter see previous section 60 To change the TSL configuration of a particular module perform the following steps 1 Click TSL and when the following screen appears ensure that Enable is selected with checkmark If it is unchecked only static labels will be displayed TSL Properties
16. smallest window size is 144x128 pixel 2x2 4 3 2x2 16 9 3x3 3x4 4x3 4x4 5x5 Window 2 Window 3 Window 4 17 Module Layout Window Layout Menu Module Layout 2x2 gt Left gt Right 4x4 gt Top gt Bottom Select from 2x2 up to 1010 left to right or top to bottom as possible grid positions on the Module Layout window Galaxy Control Window Select Menu v Open Option Menu Dock Option Menu Toggles the Option window display on with checkmark off Open Option Menu 18 Dock Option Menu Returns the Option window display to its default position on the right side of the Galaxy control window This option is not available grayed out if the previous item Open Option Menu is disabled Settings Menu Set Output Mode v Flashing Window Border Reconnect Serial Port System Parameter gt Group Parameter gt Module Parameter gt Import txt gt Export txt gt 19 Set Output Mode Changing the output resolution affects all the modules in the selected group If you have more than one group make sure you select the correct Group on the drop down menu The MCC 8004 series default output resolution is 1024x768 60 Hz rm Select ID or Add To Other Group 9i wAa ewig tig 5 ch i gh eA gh TP a Sak ay ag Sill Cap ale Top et ap TE ak ifs Sub ID eines Pe ite wedi te oka m Image Window amp Label Switch WoL wW L 5 M Imagel a I
17. the topmost window of a module 111 Examples ZX Format Function Examples ZW GGMM01 sets GGMM s window 1 as the top window ZW GGMMPP 100 200 300 400 sets GGMMPP at 100 200 400 600 ZX GGMMPP label text include the quotation marks font size where 0 is the current font size 1 4 are the available font size background extend 0 is do not extend 64 is extend outside video 0 is inside video 128 is outside video to change the label text and font size as well as specify the inner outer video ZX 000000 Input 1 Input 1 will appear as the label for all the window s in all the module s of all the group s ZX 000000 3 sets all window s label font size to 3 ZX 000000 Outside video 128 Set all windows label as Outside video with outside video 112 Firmware Upgrade This chapter familiarizes you with updating the firmware of your Avitech MCC 8004 series as well as resetting it to the factory default value 4 1 Updating the Firmware The firmware for MCC 8004 series is divided into DS80C400 C2 1 firmware FPGA MB digital clock firmware FPGA MB analog clock firmware FPGA UB firmware OSD firmware IMPORTANT Disconnect all cascaded modules connect only one module at a time DS80C400 C2 1 Firmware To update the DS80C400 C2 1 firmware perform the following steps 1 Connect the power cable to the 100 250V AC power jack on the rear pan
18. to flash To save a preset perform the following steps 1 Configure the layout to how you want it to display 85 2 Click Save File on the Option window M T Images E F T Images E D T image E F F Imager 86 3 When the next screen appears enter a unique filename for the preset and select OK to save Save File Directory E Mvitech VECS Bl K Vv Flash FileName j Display Resolution Update To Module Flash e When using a keypad use the numbers 0 9 for your preset names e When using the GPI use the numbers 1 8 for your preset names The file extension GP will be automatically added to the filename 4 Repeat the above steps for each additional preset 5 After you are done creating presets load the file that you want to be the master layout which gets loaded when the MCC 8004 series is powered on 6 Close the Galaxy program and select Yes when prompted to save to flash 87 Loading File 1 Inthe Option menu click Load File Style Master MCC_8004_d dE dL dEL r COM Group 01 Y fi z r Select ID or Add To Other Group Pol ig ig erig ig os O obese Dey ase tO ier Pasi uer 170 Pe al cee Guile PH Sits LNA te wip Sub ID late gee waht bene r Image Window amp Label Switch WoL wW L Bj Imaget Bly I Image2 alj IV I Image 5j M Iv Image4 TT PF Images E I T Images F T Image F T Image Save File Fader Control Adjustment Image Trim
19. 0255 sets the border color of group 3 module 3 window 3 as blue with 3D effect ZE GGMM 1 on 0 off to turn on off echo command response time would be much faster when echo is turned off ZE GGMM 0 Turn echo off for module GGMM RS 232 ZF GGMMPP 1 on 0 off to turn on off the video window s full screen mode ZF 010104 1 sets group module window 4 to full screen mode display ZF 010104 0 disables full screen mode for group 1 module 1 window 4 and reverts it back to its former display size Z GGMMPP if PP is 99 clock channel to set the input channel 104 Description For video window the channel values are 1 4 Examples ZK Format Function For clock the channel values are 1 internal 2 DVI 3 VITC NTSC 4 LTC 5 VITC PAL 6 NTP Network Time Protocol ZI GGMMO00 1 sets GGMM to have all window source from internal channel 1 ZI GGMM99 2 sets GGMM clock to synchronize with DVI To allow the clock input source to trigger NTP in order to synchronize the time instantly ZI GGMM99 1 2 sets GGMM clock to sync to any other source except NTP ZI GGMM99 6 sets GGMM clock to sync to NTP ZK GGMM P reset S et L oad 1 5 ID of analog clock Preset ID 1 8 HH MM SS to set the time and method of counting NTP calibration time 105 Examples ZL Format Function Examples ZK GGMM P S 1 11 22 33 sets GGMM s preset time ID1 11 22 33 Z
20. 16560 Clear Tally Status When running Tally via RS 232 use this function in the Galaxy program to close it If not then use the ASCII Z command to close Tally via RS 232 33 Setup Module Speaker ID Upon clicking Setup Module Speaker ID the following screen appears Setup All Module Speaker ID om 1 ID 1 SpeakerlD 1 om 1 ID 2 SpeakerlD 1 Speaker ID SpeakerlD1 v One group per speaker All group in one speaker Cancel Use this function to set up the speaker to monitor the audio source by assigning the Speaker ID number 1 to 60 for each module ID Click to assign One group per speaker or to assign All group in one speaker Then click OK to exit Group Parameter The following are the items appearing on Group Parameter Group Reset Allows you to refresh all modules belonging to the same group Meter There are two hierarchies for setting the Meter properties One can affect the entire group while the other affects a single window For an Entire Group To change the audio meter properties for an entire group perform the following steps NOTE Make sure to turn on all audio meters see previous section before setting the audio meter properties 34 1 Upon clicking Meter the following screen appears Meter Properties Group Display Meter Aa ViVi Wi Wi wii I MeterSW Meter Outside s 3 ee eel aul E z E 3 ae EE z z Bsa s 5 a ale lee a So oS z R TE ne NEE
21. 60H2 f 5394Hz r Audio Delay Millisecond fuo a gt Cancel UpDate 92 Use the slider to set the Audio Delay time Millisecond Click on the radio button to select 60 or 59 94 Hz frequency Select 60 Hz when the signal is for HD high definition select 59 94 Hz when it is for 59 94 Hz 1 1 001 to prevent interference on the waveform output Click the Sound drop down menu to select between Stereo Mono Left or Mono Right 93 Simplified Control Panel Aside from using the Galaxy program you can use the optional numerical Simplified Control Panel SCP keypad that allows you to quickly recall presets without having to use a computer This chapter familiarizes you with using the Simplified Control Panel to load up to ten presets saved in the flash memory of the MCC 8004 series 2 1 Using the Simplified Control Panel Optional Preparing the MCC 8004 Series For Use With the SCP Keypad To prepare the MCC 8004 series for use with the Simplified Control Panel perform the following steps 1 Create up to ten presets with filenames 0 9 up to ten groups Refer to the previous chapter on saving presets 94 Click Settings gt Group Parameter gt COM A When the next screen appears select Load File on the Mode drop down menu Then click OK Set Serial Port Communication x Setting Com jE Baud Rate 57600 bps Mode Normal X r You will be prompted to shutd
22. C Portuguese Este produto cumpre com as normas da Diretiva Europ ia 1999 5 EC Spanish Este producto cumple con las normas del Directivo Europeo 1999 5 EC Swedish Denna produkt har tillverkats i enlighet med EG direktiv 1999 5 EC vii Australia and New Zealand C Tick Marking and Compliance Notice Statement of Compliance This product complies with Australia and New Zealand s standards for radio interference vill Preface Welcome Congratulations on purchasing this Avitech MCC 8004 series The MCC 8004 series Multiviewer is a multi image video processor designed to accept either four HD SD SDI composite PAL NTSC inputs Offering output resolutions up to 1920x1200 50 60 Hz it also provides labels borders alarms optional audio meters as well as support for Asian and European character offering a fully integrated on screen display OSD for visual monitoring Allowing you to display up to 120 video inputs on a single monitor display group digital and analog video as well as audio signals can be combined in a single display The MCC 8004 series offer outstanding scalability and flexibility because individual modules can be combined to create the desired configuration Modules can be added or removed as the application requires This flexible architecture eliminates single points of failure that can cripple an entire system Component failures can be absorbed with simple built in software based proced
23. C 8004dD dDL PD PDL UD UDL Available for MCC 8004dE dEL dA dAL dD dDL PE PEL PA PAL PD PDL Q QL UE UEL UA UAL UD UDL 8 inputs Data input output Serial port Number of port 1 Baud rate up to 1 Mbaud RS 232 422 supporting TSL RS 485 Number of ports 2 DCDi processing Available for MCC 8004P PL PE PEL PA PAL PD PDL Q QL U UL UE UEL UA UAL UD UDL Power supply Consumption less than 30 watts Input 100 240 V 50 60 Hz Output 12 V DC external Housing Metal Dimension WxD 483X254 mm 19X10 inch Weight 3 6 kg 8 Ibs Environment Temperature Operating 0 C 32 F to 40 C 104 F Storage 10 C 4 F to 50 C 122 F Humidity 0 to 80 relative non condensing Parts Specifications Safety regulations FCC CE C Tick Class A Operating Features e Standalone operation single MCC 8004 series with control via RS 232 cable IP or multiple operation up to 15 MCC 8004 ACC 8000 VCC 8000 via 14 RJ 485 and DVI except MCC 8004Q cascade maximum e One MCC 8004 series can fit in a single rack unit space for a maximum of four video inputs e RJ 50 GPI terminal block adapter is provided for Tally or loading presets e Up to 26 presets configurations can be saved and recalled from the module s Flash EEPROM e Compatible with ACC 8000 and VCC 8000 modules 1 3 Identifyin
24. CC emission limits Avitech is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation vi European Union CE Marking and Compliance Notices Statements of Compliance English This product follows the provisions of the European Directive 1999 5 EC Danish Dette produkt er 1 overensstemmelse med det europ iske direktiv 1999 5 EC Dutch Dit product is in navolging van de bepalingen van Europees Directief 1999 S EC Finnish T m tuote noudattaa EU direktiivin 1999 5 EC m r yksi French Ce produit est conforme aux exigences de la Directive Europ enne 1999 5 EC German Dieses Produkt entspricht den Bestimmungen der Europ ischen Richtlinie 1999 5 EC Greek To mpotdv avt n npo tis TPOPAEWEIs tno Evporaik s Odnyias 1999 5 EC Icelandic essi vara stenst regluger Evr pska Efnahags Bandalagsins n mer 1999 5 EC Italian Questo prodotto conforme alla Direttiva Europea 1999 5 EC Norwegian Dette produktet er i henhold til bestemmelsene i det europeiske direktivet 1999 5 E
25. EE A PEE rad tara te EE E teats See bet en TAA 103 A ORERETAN ETE A E EE A EE S TTA 103 vA VAE EEE E AEAT E PEE NEATA AERA 104 VA eo ie ee ae a te eee ee 104 Z Denetara eoi ae ele eee 104 vA RAE E dts ital din ete inte an ter is ota stein tect Mats 105 VA sateen TEAT EA A E EA E E E le teenth 106 ZM a ena a Baltes este eae ae ane E a 107 DIN EE EE O AE E E EA Asa E eenaree 108 ZO secrets Sit E E eso 109 VA ee Eee err eRe reer epee rere reece rer Ere reer ere 109 RS id devs gs eda tas 2a ast a a din teavitea tee ete aad 109 A tanwr etnies acd ae ed ee ee ee 110 DV siete tee ae ian ee eee 111 VA AEA AEE E E TSE EA beetle Meee ated ho 111 VA ERO EEE E T E E E ES 112 Firmware Upgrade icine caceciecnetacentadescensueesninerennniensednvedaneniunens dies 113 4 1 Updating the Firmware 2 0 0 0 ccccecceeeeeeeeeeeeeeeeeeeeeeeeeseenaeeeeeenaeees 113 DS80C400 C2 1 Firmware ccccceeeseceeeeceeeeeceeeeeseeeeseaeeeseeeeeas 113 FPGA MB Digital Clock Firmware 0 ccccceesseeeeeeeseeeeeeeenteeeeeeaes 115 FPGA MB Analog Clock Firmware ccccceesseeeeeeeeteeeeeenteeeeeneaas 117 FPGA UB FIWA raona oo a E OEA A AKEE AEEA AN 118 OSD FiInmWware aaa a O E AOE 120 4 2 Resetting to the Factory default State eeeeeeeeeneeeeeeeneees 121 GIGSSALY essai E E T 122 p Warranty Avitech International Corporation herein after referred to as Avitech warrants to the original purchaser of the products manufactured i
26. Fimwae J FPGA MB Digital Clock Path Browse e ____ Browse Path jf FPGAUB Path Browse x OSD font Alarm Path Browse 3 Click to select the IP checkbox with the factory default 210 100 100 151 value In case you have changed the IP address of your MCC 8004 series then make sure to enter the correct IP address 117 4 5 6 Click to select the FPGA MB Analog Clock item then click the Browse button to specify the location of the firmware file and select AT MCC 8004MB A 080121 rbf for MCC 8004d Q AT MCC 8004MB A0121 08 rbf for MCC 8004a aA P U Others Module Style MCC 8004 v Clear All File Using Digital Clock Change IP Address Using Analog Clock M com fi MIP 210 100 100 151 Ping D j amp COM A Setup JV FPGA MB Analog Clock Path Browse i Firmware f FPGA MB Digital Clock Path p Browse a J OSD font Alarm Click the Update button located on the left lower portion of the screen Reboot unplug and re plug the power cord the MCC 8004 series when FPGA MB Analog Clock firmware update is successful NOTE Shutdown and startup of MCC 8004 series needs to be done to completely update the FPGA MB Analog Clock firmware FPGA UB Firmware To update the FPGA UB firmware perform the following steps l Run the Galaxy program by double clicking the Galaxy V311 exe f
27. K GGMM PL 1 sets GGMM s time to be the same as preset time of ID1 ZK GGMM P 2 use analog clock shape 2 Format for NTP calibration time ZK GGMM C alibrate HH MM ZK GGMM C 2 30 execute NTP calibration every 2 5 hours This setting will trigger NTP calibration instantly Format for control ZK GGMM HH MM SS 0 count down 1 count up 2 pause 3 do not pause 4 invert pause status counting method ZK GGMM 11 22 33 sets GGMM time to 11 22 33 ZK GGMM 11 22 33 0 sets GGMM time to 11 22 33 and counting down ZK GGMM 1 sets GGMM clock to start counting upwards ZL GGMMPP clock 00 255 transparency 000000000 RRRGGGBBB set text color 000000000 RRRGGGBBB set label color TEXT label text string 50 ASCII characters maximum to set the label s transparency text and text color ZL GGMMPP 0 255000000 000000255 CNN News Station sets GGMMPP to no transparency text color red label color blue with text CNN News Station NOTE All windows will share the same label transparency setting That is upon changing one window s label transparency all other window s label transparency will also be changed simultaneously 106 ZM Format ZM GGMMPP resolution number No Automatic arrangement Function to change the output resolution the resolution number refers to the list of resolutions the MCC 8004 series supports Description Vertical Frequency Resolution 50 Hz 60 Hz
28. MB A BIOS V2 35 0m 01 21 2008 OSD BIOS 1 04 00 07 23 2007 UB BIOS V2 39 0n 02 13 2008 CB BIOS 1 00 17 07 31 2008 MB BIOS 2 00 02 03 24 2008 UB FPGA V1 08 0r 09 06 2007 UB 1601 1 00 90 07 29 2008 0SD BIOS V1 01 0y 07 25 2007 coc 2 Assign a filename and click Save to save the data Export All Information Save in Temp gt et E dump txt E Label TT AIL Fw Hw info Save as type Pos File TXT 7 Cancel A 64 Update BIOS Allows you to update the BIOS firmware version of your MCC 8004V series Upon clicking Update BIOS the following screen appears see the succeeding chapter for details on upgrading the firmware Update BIOS CB R5232 COM ID fi F Chip P Chipz I Chip sue E Baudrate 57600 115200 Delay Time File Path ja Others Module Style J s 4 IIP 0 0 0 D Ping ID j COM A Setup Firmware T FPGA MB Digital Clock Path mee eee Browse a FPGA MB Analog Clock Path E Browse T FPGA UB Path E Browse J OSD font Alarm J gm1601 Chip1 47 gm1601 Chip2 47 gm1601 Chip3 J omi60i Chips 47 F Path en Browse l F OSD font Ph Bronse T Boot Logo Module Information iis E Bua Browse SerialNum HardwareRey CI B r Screen Logo Model Name ue Path Build Browse i L Alias u J Clock Background AssetiD OOO Ss Path Build Browse Read Descripti
29. Shell Version 2 0 Initializing 0 K gt 4 To logout of the ASCH Z command interface type exit and press Enter Dis 513 a E Welcome to AVITECH ASCII Command Shell Version 2 0 Initializing 0 K gt exit Bye gt 101 3 4 ASCII Z Command Format The ASCII Z command is comprised of the following parts The following is a list the rules to follow when entering the ASCII Z command It is acceptable to enter commands in small or capital letters and the five columns are separated by a space Header z command character Group Module Window Assignment GGMMPP is comprised of six Arabic numerals This is used in designating the device s Group Module Window assignment Group is comprised of the first two numbers 01 99 00 is used to pertain to all groups Module is comprised of the middle two numbers 01 15 00 is used to pertain to all modules Window Assignment is comprised of the last two numbers 01 04 00 is used to pertain to all window assignments Parameter 1 of color assignment RRRGGGBBB is comprised of nine Arabic numerals this is used in designating the color Parameter 2 of on off switch 1 signifies ON while 0 signifies OFF The following is a list of available ASCII Z commands for the MCC 8004 series ZA Format ZA GGMMPP NByN 2 3 Nth 4 2 Function to set the automatic arrangement of windows 102
30. User s Manual MCC 8004 series Revision 1 0 July 2009 WARNING Do not attempt to disassemble your MCC 8004 series device Doing so may void your warranty There are no serviceable parts inside Please refer all servicing to qualified personnel TRADEMARKS All brand and product names are trademarks or registered trademarks of their respective companies COPYRIGHT The information in this manual is subject to change without prior notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Avitech International Corporation Avitech International Corporation may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except as expressly written by Avitech International Corporation the furnishing of this document does not give you any license to patents trademarks copyrights or other intellectual property of Avitech International Corporation or any of its affiliates TECHNICAL SUPPORT If you have any questions regarding the information provided in this guide call our technical support help line at 425 885 3863 or our toll free help line at 1 877 AVI TECH You can also email to support avitechvideo com Table of Contents Warranty si sisccscdaves nevis ccenestensscencernnsesanneceuseceneescerssexcesexeweseoevesensserused ewnses iv
31. V Iv Image2 5 Vv IV Image3 5 Vv Image4 il T VF Images E M T Images E F T image j M T Image Load File Save File Fader Control Adjustment Image Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com4 20 l Click Settings and then click Set Output Mode fae Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select EA Special Screen Layout Help SES Set Output Mode v Flashing Window Border Image3 Reconnect Serial Port Clock System Parameter Group Parameter Module Parameter Import txt Export txt When the following screen appears set the output resolution to match the monitor display s Select the Refresh Frequency select the Mode from the drop down menu and then click OK You will notice that the selected resolution is displayed on the top bar of your Galaxy program Set Output Mode Refresh Frequency 50Hz 60Hz fE E Mode 1280x1024 Cancel 21 Flashing Window Border When the Flashing Window Border option is enabled with checkmark the border of the window where the mouse cursor just resided will blink twice to notify you of its location fae Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select ein Special Screen Layout Help a Set Output Mode v Flashing Window Border Reconnect Serial Port Image2 211 Image3 Image 2 Image2 System Parameter Group Parameter Module Parameter Import txt
32. VITC NTSC C VITCIPAL LTC C NTP _NIP Properties Time Time Zone I Daylight GMT Greenwich Mean Time Dublin Edinburc fo fe far Update PC GMT Time Update 45 The analog clock works differently compared to the digital clock in that you cannot use the drag and drop feature to re size You can only select from the following 192x192 224x224 256x256 320x320 or 384x384 To activate the time code feature on the Source portion click the mouse to select Free Run LTC or VITC NTSC PAL You can also synchronize the clock from the slave module by clicking the mouse on Slave to select it Then click the Update button on the lower right portion and then click OK The NTP time code feature allows the MCC 8004 series to synchronize the clock with an external NTP time server The IP port on the rear of the MCC 8004 series can control as well as receive time code information at the same time To set up the NTP time code perform the following steps 1 Make sure that Count gt Up is selected Clock Properties Group M Label Total Characters 32 7 I BMP Label Font Color B G Color W Size fi gt Analog Clock Size 152s AO IV Border I Hide Switch Fullscreen mode C fue e oov Forcan E eac Source C Freern Slave C VITCINTSC VITC PAL LTC NTP Time Time Zone r T e Iie OK Cancel Jpdate 46 On the Source portion c
33. aan Clear Save Module Info List Update 65 Update Signal Type Format To update signal type format click Update Signal Type Format and the next sample screen shows the entire image signal type format Signal Type Format x Image1 SD_SDI_PAL Image2 SD_SDI_PAL Image3 SD_SDI_PAL Image SD_SDI_PAL Module Signal State To find out the module s signal state click Module Signal State Backing Up Presets To backup a preset perform the following steps l Click Backup All Information the following warning message appears Click OK to continue A Old informations will be deleted The following message appears when back up is successful click OK to continue Backup Successfully This will backup all saved presets and system configuration files to c Avitech_VCC Backup XXxx _ WARNING Everything in the Backup folder will be erased If you have previously backed up presets they will all be written over when you backup presets again If you want to keep the old presets move the entire Backup folder to a temporary directory e g c temp 66 This will create the following directories c Avitech_VCC Backup c Avitech_vCC Temporary Restoring Presets To manually restore a preset perform the following steps 1 Upon clicking Restore Module Information you should see a progress bar showing the preset being loaded into the MCC 8004 series 2
34. ading four modules then it will be divided into four groups When the next screen appears click OK to finalize the changes WARNING A This action will be setting one module per group The configuration progress will be shown on screen Writing Preset Files to Module IP 210 100 100 119 1D 2 Flashl Waiting lt o KE NOTE e The group s sequence would be set according to the Rotary ID number in an ascending order When in full screen mode the window layout prior to full screen mode would automatically be restored before grouping After grouping the module s preset file will be cleared The MCC 8004 series system agi new configuration file module sys and software ini files will be updated 29 Or another method for creating new groups is 1 Right click the mouse on the module you wish to add to the new group Then click Set ID To gt New Group Style Master MCC_8004_d dE dL dEL m COM Group T z z r Select ID or Add To Other Group c a E Sub ID SF i ig 2 m Image Window amp Label Switch WoL WoL BAM M magl set IV Image2 5j M M Image3 5j M M Image4 Ej I T Images E I T Images E I V Image M T Image Load File Save File Fader Control Adjustment Image Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com 2 Repeat for all additional modules you can either add additional modules to the new
35. aeeeeneaes 7 1 6 Using the Galaxy Program c cccceteeeeeeeeteeeeeeeeieeeeettieeeeetnieeeere 10 Module Layout Window ccccesecceeeeeeeeeeeeeeeeeeaeeeeeeaeeeeeenaeeeeseeaas 18 Galaxy Control WiINdOW ccceeeeeeeeeeeeeeeeeneeeeeteaeeeeeeeneeeetenaeeeeeeaas 18 Quick Keys Change Window to from Full Screen Mode Swap Window Content cccccccceceeceeceeeeeeeeeeeaeaeeeeeeesetsnseeaeeeeees 70 Window Layout 0 cece cence ee eeteee ee eecne ee erties ee eeeeeeenieeeeetiaeeeees 70 2 3 Option WiIndOW ae erenn aiaee anere r aai aeea a e a E aeaa a 72 Mouse Right click Menu ssssseeeeerisserrsserrrssrirrssrrrrssstrrnssrrrrssrrens 73 Simplified Control Panel cceecceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeees 94 2 1 Using the Simplified Control Panel Optional cceeeeeeeeeeees 94 Preparing the MCC 8004 Series For Use With the SCP Keypad 94 Recalling Presets cn decade Matin ce ei i eh 95 Avitech ASCII Protocol ccccceccceseeeeeeneeneeeeeeeeseeeseeeeeeeeeeeeennes 98 3 1 Setting the RS 232 Port cccccccccccceeseceeeeeceeeeeseaeseeneeeseaeeesaeeneneeees 98 3 2 Setting the HyperTerminal s COM Pott eeeeeeeeesereeeeetteeeeeenaes 99 3 3 Entering the ASCII Z Command Interface s 100 3 4 ASCII Z Command Format cc ccccccceeeeeeeeeeeeeaeeeeeenceeeeeenaeeeeeeaas 102 VA cic hd Meera setae rene Ade eames ty oi EEEE E ele AS eaen T 102 VA P
36. allow MCC 8004 series to recall the 1 GP1 file Example 2 pressing 2 two gt point or period gt 1 one gt 7 seven gt Enter total of five keys would allow MCC 8004 series to recall the 17 GP2 file Example 3 pressing 3 three gt point or period gt 2 two gt 6 six gt Enter total of five keys would allow the MCC 8004 series to recall the 26 GP3 file To save the MCC 8004 series present configuration press star or asterisk gt slash gt Enter total of three keys During this process approximately five seconds make sure that your MCC 8004 series has a stable and uninterrupted power supply When the DVI I port has an analog VGA input the MCC 8004 series can do automatic image adjustment by pressing the following three keys point or period gt star or asterisk gt Enter 96 When the DVI I port has an analog VGA input the MCC 8004 series can do automatic gain adjustment by pressing the following three keys point or period gt slash gt Enter To logout from the Simple Control Panel mode just unplug the SCP keypad from the rear panel s Keypad port 97 3 Avitech ASCII Protocol The MCC 8004 series supports the ASCH command prompt interface you can use HyperTerminal to control your MCC 8004 series The serial port RS 232 on the MCC 8004 series can also be used to interface with a third party controller for control over RS 232 This chapter
37. alog Clock eT h Path Boan Ee J7 OSDffont Alarm Path Browse 5 Click the Update button located on the left lower portion of the screen 119 6 Reboot unplug and re plug the power cord the MCC 8004 series when FPGA UB firmware update is successful NOTE Shutdown and startup of MCC 8004 series needs to be done to completely update the FPGA UB firmware OSD Firmware To update the OSD firmware perform the following steps 1 Run the Galaxy program by double clicking the Galaxy V311 exe file Click Others when the following screen appears Communication Modes Serial Port C User Define 1 J Fast Z F Rainierta 4d 4alv 4dly M mecsoo1 IP C User Define C Automatically Search Cancel 2 Select Others and on the Module Style drop down menu select MCC 8004 Uthers Module Style MCC 8004 v com fi mie 210 100 100 151 Ping 0o fi A Firmware FPGA MB Digital Clock Path Browse Path Browse Clear All File Using Digital Clock Change IP Address Using Analog Clock COM A Setup J FPGAUB Path Browse J OSD font Alarm Path Browse 3 Click to select the IP checkbox with the factory default 210 100 100 151 value In case you have changed the IP address of your MCC 8004 series then make sure to enter the correct IP address 120 4 Click to select the OSD checkbox and then click the Brow
38. ancel 3 Set the Baud Rate NOTE When cascading with other MCC 8004 series the baud rate should set to 57600 bps 4 Select the Mode e Normal for configuring the serial port of the module with PC configuration and control e AVR for configuring the serial port of the module with AVR connection e Load File for use with the SCP Simplified Control Panel keypad e TSL V3 1 for configuring the serial port of the module with TSL connection The initialization process is different so the same TSL connection for other Avitech products may not function correctly with the MCC 8004 series without additional changes 5 Select the Detect Slave Module Mode Fast Default 6 After setting COM A you may be prompted to close the Galaxy program and power cycle shutdown and restart the module 50 TSL The MCC 8004 series includes one RS 232 port that is used for connecting to a PC for configuration control and connecting to TSL controller One TSL port of the TSL controller is needed for connecting to the first module of each group To setup the configuration perform the following steps 1 Select Settings gt Group Parameter gt COM A 2 On the Mode drop down menu select TSL V3 1 The Baud Rate will automatically adjust to 38400 bps according to TSL specifications Set Serial Port Communication E Setting Com A ja je jz Baud Rate Mode ERA z Detect Slave Module Mode Fast Defaut x r
39. andard for communication between a monitor display and a video adapter Using DDC a monitor display can inform a computer s video card about its properties such as maximum resolution and color depth to ensure that the user is presented with valid options for configuring the display A collective number of video or image windows showing on a monitor display Basically the Group defined here is the display device that is connected to the last module s DVI I Out port Contains the layout that gets loaded every time the module is powered on Connects to the PC via RS 232 cable or IP to function as the controlling module when cascading more than one module the module s sys file contains the module ID model name IP address Tally configuration data the preset s gpx file contains the layout label border configuration data A circular dip switch used to set a unique ID to each MCC 8004 module The rotary ID selector switch s range spans from 0 9 and then from A F For the Galaxy program to recognize specific modules in a group each module in a group setting HAS to have a unique ID number When ran the program will detect a module s specific ID and add unity to it Therefore if a module has an ID of 1 the program will detect it as ID2 while an ID of 2 will be detected as ID3 and so forth Module that is cascaded with and controlled by the master module the system agi file contains the group number and
40. ck About You should see a pop up box showing the Galaxy program information Module Controller Galaxy Y3 11 2009 05714 AECE 69 Quick Keys Change Window to from Full Screen Mode Swap Window Contents Two quick keys are available that allows you to quickly bring a window to from full screen mode as well as swap the contents from one window to another by performing the following steps 1 To change to full screen mode double click the mouse on a window Double click again to return from full screen mode 2 To access the swap window quick key move your cursor to the bottom left hand corner of a window until a capital letter S appears 3 Click on the capital letter S to select the source window and then click again at a destination window where you want to swap the contents from the source This will swap all the contents and properties of the source window to the destination window Window Layout Setting the Default Layout by Group When you have multiple units cascaded together you can quickly show all the windows by selecting Settings gt Group Parameter gt Set Default Layout 70 Arranging Windows by Group To quickly setup the layout for your video windows right click the mouse on the blue information bar to access the Group Layout menu Select from 2x2 up to 5x5 as possible grid positions on the monitor display fae Avitech Galaxy 1280x1024 60Hz Baud 5760 Group Layout Selec
41. crosoft Corp C Documents and Settings Admin gt 11 3 Type ping 210 100 100 151 and the following screen appear to signify a successful communication O x Microsoft Windows XP Version 5 1 26001 lt C gt Copyright 1985 2661 Microsoft Corp C Documents and Settings AdminD gt ping 216 166 166 151 Pinging 216 166 166 151 with 32 bytes of data from 216 166 166 151 hbytes 32 time 4ms TTL 255 from 216 100 166 151 bytes 32 ti TTL 255 from 216 106 160 151 bytes 32 ti TTL 255 from 216 160 166 151 bytes 32 time 3ms TTL 255 Ping statistics for 216 166 166 151 Packets Sent 4 Received 4 Lost loss Approximate round trip times in milli seconds Minimum ims Maximum 4ms Average 2ms C Documents and Settings Admin gt 4 Type exit to exit the Command Prompt screen 5 Run the Galaxy program by double clicking the Galaxy V311 exe file When the following screen appears under Serial Port select Automatically Search ommunication Modes Eg Serial Port l Fast r mR Papei I Rainier4a 4d 4alv 4d1v 9 M mccsoo1 IP C User Define C Automatically Search Cancel Others 6 Click OK and your computer would start to search for your MCC 8004 series 12 NOTE e If you have two or more modules cascaded they should also be detected e Make sure that the slave module s baud rate and resolution is the same as the master module s 7 Upon finding your device th
42. default setting for output timing is Normal Normal VESA VGA to Background Allows you to alter the sequence of a particular cascading window that appears on the monitor display By default Window 1 should appear on top of Window 2 but you can move it to be behind Window 2 into the background 55 Window Size There are three window sizes which could display all the windows in a group namely 4 3 16 9 or Lock Aspect Ratio Set Aspect Ratio 4 3 Set Aspect Ratio 16 9 On Lock Aspect Ratio gt off When changing the width of the window the height will automatically adjust to match the aspect ratio When Lock Aspect Ratio is set at On the aspect ratio of the video display will be maintained even if the window is stretched If the image is 4 3 and it is stretched to 16 9 the result is two vertical black bars appearing on either side of the display If the image is 16 9 and it is scaled down to 4 3 then it will have a letterbox effect Set Default Layout When you have multiple units cascaded together you can quickly show all the windows by selecting Set Default Layout Module Parameter The following are the items appearing on Module Parameter IP Address Allows you to change to an IP address different from the default one Set C2 IP Address IP address Am 100 100 151 Subnet mask 2 255 255 D Gateway 210 100 100 254 56 Auto Parameter The MCC 8004 series can automatically detect the di
43. e following screen appears to confirm connection to your MCC 8004 series Configuration Report Com 1 1D 1 MCC_8004_d dE dL dEL 2 No Cancel For standalone module Configuration Report Com 1 ID 1 MCC_8004_d dE dL dEL ID 2 MCC_8004_U UL UE UEL ID 3 VCC 8004U lt RA N Cancel For cascaded modules NOTE Make sure the cascaded modules have different rotary ID settings e g 1 2 3 on their rear panels 13 8 Click OK and the following screens appear Module Layout window Galaxy control window and Option window Module Layout ee Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Style Master MCC_8004_d dE dL dEL COM Group a Select ID or Add To Other Group a il ee w shig c c c c Cc c c c Sub ID o Cc e e Image Window amp Label Switch wW L Ww L EV M image jM M Image EA M images M M Imaget Brr Er Enr Err Image4 LoadFile Save File Adjustment Position Fine Adjustment Size Fine Adjustment Check Audio Set ComA e Module Layout window contains the bird s eye view of the module layout belonging to each ID in the system In this example the top window displays the layout belonging to ID 1 on the Galaxy control window the middle window displays the layout belonging to ID 2 while the bottom window displays the layout belonging to ID 3 Mod
44. e menu appears as shown next Module Reset IP Address Y Delay Auto Parameter gt Output Timing gt v Clock Window Cascade In YGA Only Tally YGA to Background Analog Clock f Screen Logo gt GPI Definitions Preset Time ACC Setup ACC Alarm v YCC OSD TSL Rainier Cascade In mode YGA Auto Setting br VGA Auto Detect Position gt YGA Auto Detect Gain gt Frame Lock Fullscreen mode Line Lock NTSC Black Level gt Frame Memory Status gt 26 Importing Exporting Label Allows you to import label from export label to Microsoft Excel or Notepad to be edited externally Settings Special Screen Layout Help Set Output Mode Video Standard gt v Flashing Window Border Reconnect Network Reconnect Serial Port Frame Memory Bypass gt cade In gt Set C Cascade In Auto Scan System Parameter Group Parameter Module Parameter gt BMP Label Unicode gt Label ANSI Export txt Settings Special Screen Layout Help Set Output Mode video Standard v Flashing Window Border Reconnect Network Reconnect Serial Port Frame Memory Bypass gt v Set Cascade In Cascade In Auto Scan b System Parameter Group Parameter Module Parameter gt Import txt gt BMP Label Unic
45. e the border properties for an individual window right click the mouse on the window and select Set Border then select the desired color and size 41 Activating Tally The RJ 50 to GPI terminal block allows for a total of eight inputs to activate Tally two per window You can also use the serial port with ASCII TSI or TSL to activate the Tally To change the appearance of the Tally perform the following steps 1 Upon clicking Tally the following window appears Tally Properties Group JV Clear Tally status M Show Set Tally Color G Tally C Tay 2 E C Taly3 LED 1 LED 2 LED 3 Flash Set GPI Serial Tally Event GPI GPI 1 M LEDI M Label V Border GPI 2 W D2 F Label J Border Serial Tally 1 M LED1 Label JV Border Tally 2 M LED2 I Label J Border Tally 3 MV LED3 J Label J Border Cancel Tally 1 2 and 3 are triggered by GPIO 2 The settings that can be adjusted include Tally Color LED Label Border and Flash NOTE Tally 1 2 3 can trigger either Label or Border but there is only one border or label If Tally 1 2 3 are triggered simultaneously the display priority will be Tally 1 then Tally 2 then Tally 3 42 Setting Alarm Properties Allows you to setup the notification when a signal is missing For an Entire Group To set the alarm properties click Alarm and the following screen appears Click to enable Module Alarm Switch that allows you to set the Process Video
46. each z 9 z 3 a 20 z z PA J 2 20 42 3 r eE e H 128 L 0 LPR LPR LPR LPR WU 4 0 DBu H 230 L 25 Phase Meter Meter 2 Meter3 Meter 4 Sound AAGan Group 1 X Group 2 Y rE MEE All Process r Transparency Jo Cancel Update The MCC 8004 series is capable of displaying embedded audio as VU volume unit meters inside the video window Embedded audio is divided up into four groups with a master and secondary channel for each group allowing you to display the left and right VU meter of either the master or secondary channel on the left and right side of the window just as the menu depicts 2 To change the group select it from the Group 1 4 drop down menu NOTE When there is no audio detected you will NOT see any VU meters 3 Use the sliders to adjust the Phase H L sliders VU one slider Sound H L sliders A A Gain one slider 35 For an Individual Window To change the audio meter properties for a single window use the mouse to right click on a window and then click Set Meter Size gt Full Screen Select Source VCC 4xDYI gt Check Signal Set Label Set Meter Set Border Safe Area UnderScan Set Alarm Aspect Auto Detect TSL Label There are two hierarchies for setting the Label properties One can affect the entire group while the other affects a single window For an Entire Group To set the label properties perform the f
47. el of the MCC 8004 series and the other end to an electrical outlet Use a serial RS 232 cable and connect one end to the MCC 8004 series rear panel s RS 232 port and the other end to the computer s serial port side 113 3 Run the Galaxy program by double clicking the Galaxy V311 exe file Click Others when the following screen appears Communication Modes Serial Port I Fast Cc i 1 Hsien J Rainier4a 4d 4alv 4dly J mccso01 C User Define C Automatically Search Cancel 4 When the following screen appears click to select the radio button for CB RS232 and on the Style drop down menu select DS80C400 C2 1 Update BIOS CB RS232 comf iD fi x r F C ja fi Style 4X11015 CB Fi tyle CB Firmware ad M c Delay Time 1 Browse ila i 1 Rainier4x1v SSS eae File Patt CCe001U 2668 MCC8001U MCU 8051 Others 4511015 BootLoader 11015 CB Firmware Modull Rainier4UI1v MB 1601 r Firmware j COM A Setup 5 Select the COM port number you are using to connect the MCC 8004 series to the PC from the COM drop down menu 6 Select the Delay Time 1 5 10 15 20 25 30 35 40 from the drop down menu 7 Click the Browse button to specify the location of the firmware file and selectmec 8004d hex for MCC 8004d mcc 8004u hex for MCC 8004Q P U mec 8004a hex for MCC 8004a mcc 8004aa hex for MCC 8004aA 8 Push the number 1 dip switch located on t
48. er ID Setup Group Module Cascade Series Use the DVI Switch function to enable or disable Cascade In for each ID number Use the Cascade Series function to change the ID number designation only this will not affect the actual physical connection of the MCC 8004 series DVI Switch amp Module Cascade Series Group 1 gt D I Switch r Cascade Series Cascade In DYI Output x x xj x DYI Output v Vv Cascade In Cancel 32 Advanced Upon clicking Advanced the following screen appears Software Parameter IV Use Broadcast Load File J Automated Backup Files to Hard Drive Backup Path C Avitech_MCC BackUp Browse No Signal size refer to NTSC e Use Broadcast Load File For loading preset switching resolution group reset When this option is enabled with checkmark the Galaxy program will broadcast the command to every module allowing for simultaneous execution of the command NOTE This feature should always be enabled e Automated Backup Files to Hard Drive By default the Galaxy program will save all backup files to the C Avitech_VCC BackUp folder You may change this by clicking Browse to select a different location to save the backup information e No Signal size refer to When the window is unable to detect a signal this will serve as the basis for the Galaxy program to adjust the window size NTSC maximum window size is 816x465 PAL maximum window size is 8
49. er creating the master layout and you want the MCC 8004 series to load it again when the unit is power cycled shutdown and restart e After you are done saving presets and you want to save all the presets that were created into the internal flash memory of the module If this action is skipped the module will lose all the presets that were created To save to flash perform the following steps 1 Click Save File on the Option window Style Master MCC_8004_d dE dL dEL COM r Group 01 X 1 v Select ID or Add To Other Group gigs ep Yg ts 0 Pate iy acto unt Site 0 roi 3 ma micas mien i r Sub ID FP a tae ig te and m Image Window amp Label Switch wW L I Imagel 5j IV IV Image IV Image3 5 M M Image4 I image5 I Images F Image Load File Adjustment age Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com4 84 2 When the following screen appears click Update to Module Flash and then click OK Save File Directory C Avitech VES Bl x M Flash FileName jj Display Resolution Update To Module Flash Or close the Galaxy program and select Yes when prompted to save Saving a Preset All the presets you create are stored in the MCC 8004 series and not in the computer that is running the Galaxy program In order to write all the presets into the internal flash memory of the MCC 8004 series after creating it you will need to save
50. erface perform the following steps 1 Connect the HyperTerminal s COM port PC to the MCC 8004 series RS 232 port and make sure that power supply is available 2 Connect the power cord to the MCC 8004 series so that it will use the default baud rate 57600 bps to transmit the startup signal Dla sl 3 ala El AX110xx family bootloader v2 0 0 1 Execute Runtime Download runtime via RS232 3 Download runtime via Ethernet 4 Download new bootloader via Ethernet Please input 1 2 3 or 4 to execute above Wait runtime code Starting up Initializing I2C bus in I2C_FAST I2C_7BIT I2C_MASTER_MODE OK Initializing GCONFIG Read EEPROM dat EEPROM DATA a bc 03 80 30 00 Oe 00 00 21 23 00 f2 05 10 59 d 19 87 00 ff ff ff ff 10 03 00 a8 cO 00 ff f tf ff Initializing software timer module OK Module ID is 0x3 UB_FPGAConfigure OK Initializing high speed UART OK Initializing file system 0K Initializing ethernet and TCP UDP command server OK MAC Address 8 23 21 0 0 e IP Address 192 168 0 151 Initializing RS 232 command server OK RS 232 COM port is working in Normal mode at 57600bps Initializing RS 485 command server OK 100 3 Press Enter to login to the ASCII Z command interface When the HyperTerminal s command prompt gt symbol appears you can start entering ASCH Z commands Dls 3 lal s Welcome to AVITECH ASCII Command
51. f four windows Upon clicking on this item select from the following layout as shown on the next screen Setting Layout E H E Cancel 62 e Layout 6 Briefing cycle between presets for a slideshow effect Briefing C Avitech_VCCWefault Group ProcessName Time H M S Load File Path H 0_M 1_S 0 C Avitech_VCC T emporary IP210 100 100 151 C Avitech_VCC T emporaryIP210 100 100 151 C Avitech_YCC T emporary IP210 100 100 151 C Avitech_VCC T emporaryIP210 100 100 151 C Avitech_VCC T emporary IP210 100 100 151 C Avitech_YCC T emporarysIP210 100 100 151 Add Insert Remove Clear Alteration Load Save C AutoPlay Play Manually Repeat P Help Menu fae Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select Settings Special Screen Layout ips Read BIOS Version Update BIOS Update Signal Type Format 3 Module Signal State Image1 Backup All Information Restore Module Information Preset to ASCII Image4 Abo Image3 63 Read BIOS Version To find out the Avitech MCC 8004 series module firmware version perform the following steps 1 Click Read BIOS Version When the following screen appears click Export E Display BIOS Version BIOS Version CB BIOS V6 04 15 04 20 2009 MB D BIOS V1 00 01 11 03 2006 MB 4 BIOS 1 00 0m 10 13 2006 OSD BIOS 1 02 00 09 21 2006 UB BIOS V1 11 00 07 07 2006 CB BIOS V6 03 15 08 11 2008 MB D BIOS V2 30 01 01 23 2008
52. familiarizes you with using the Avitech ASCII Protocol AAP of the MCC 8004 series via Microsoft Windows HyperTerminal function as an example 3 1 Setting the RS 232 Port Before using the ASCII Z command interface make sure that the COM A RS 232 port on the MCC 8004 series is set at Normal 8 bit data stop bit no parity and no flow control The default baud rate is 57600 bps To correctly use the ASCII Z commands use the Galaxy program s default Group and Module number for the MCC 8004 series Refer to the previous sections for details 98 NOTE e Toset COMA to Normal Click Settings gt Group Parameter gt COM A When the next screen appears select Normal on the Mode drop down menu Then click OK e Disconnect the SCP keypad if that is connected Set Serial Port Communication x Setting Com m RS232 fE Baud Rate 57600 bps x Mode Normal i Detect Slave Module Mode Fast Defaut x 3 2 Setting the HyperTerminal s COM Port To set the HyperTerminal s COM Port perform the following steps l Click Start gt All Programs gt Accessories gt Communications gt HyperTerminal to startup the Windows HyperTerminal function Set the HyperTerminal s COM port to the following settings same as RS 232 port setting Baud Rate 57600 Data Bits 8 Parity None Stop Bits 1 Flow Control None 99 3 3 Entering the ASCII Z Command Interface To startup the ASCII Z command int
53. g the Front Hardware Component oO Ref Component Description PowerLED Lights green when the MCC 8004 series is powered on 1 4 Identifying the Rear Hardware Components D EO Ref Label Component Description int 2 3 4 BNC connectors for HD SD SDI composite video inputs Audio Inputs Connector for up to four analog stereo pairs AES audio inputs Analog Out VGA connector for output to monitor display Audio monitoring BNC connector for audio cascading input cascade 9 Audio monitoring output BNC connector for analog audio output 10 Keypad RS 232 connector for signal from optional TACP Touch screen Control Panel or numerical Simplified Control Panel SCP keypad RS 232 RS 232 connector for signal from PC Inout 5 6 7 8 BNC connectors for HD SD SDI composite video input loop passive for analog video active for digital video Cascade In DVI I connector for multimedia input cascade from other MCC 8004 ACC 8000 VCC 8000 series device DVI I Out DVI I connector for output to monitor display Pl RJ 50 connector for GP input output Ref Label Component Description B IP Ethernet connector for using the computer s Galaxy program to perform setup on the MCC 8004 series Dip switches The left dip switch is for updating the firmware while the right dip switch is for returning the MCC 8004 to the factory default setting ID Rotary dial to assign uni
54. group cascading module s configuration data 122
55. group or create additional groups 30 3 To switch between the different groups use the Group drop down menu Select ID or Add To Other Group Ko we weogt g oo tg of igh Is tg sig co allies Wed Zaes nl Sues wad 4 erp r Sub ID SiG eo oa r Image Window amp Label Switch wW L wW L 5 M M Imaget S IV v Image2 5 M M Image3 5 M M Image4 B eos BH maes E M T Image Bj M T Image Load File Save File Fader Contro Adjustment age Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com4 4 Exit the Galaxy program and select Yes when prompted to save to flash memory Save System Files to Flash Allows you to save all configuration settings to flash memory If the system configuration has been changed save the changes first before continuing the other configuration settings The progress of saving to flash memory will be displayed Update Module IP 210 100 100 119 1D 2 System Files to Flash 31 Turning On Off All Meters Labels Clocks TSL To turn on off all meters labels clocks TSL for all the modules regardless of the group it belongs to click ON OFF Return Group Index to Default One Module Per Group Save System Files To Flash All Meters gt ON All Labels gt OFF All Clocks gt All TSL gt Module Cascade Series Advanced Clear Alarm Message Locked state Clear Tally Status MKC Properties Setup Module Speak
56. he MCC 8004 series rear panel downward to the ON position 114 9 Click the Update button located on the left lower portion of the screen 10 Push back the number 1 dip switch upward to the default position 11 When the next screen appears pull off the power cord from the power jack to shutdown the MCC 8004 series then re attach the power cord to restart the MCC 8004 series FPGA MB Digital Clock Firmware To update the FPGA MB digital clock firmware perform the following steps 1 Run the Galaxy program by double clicking the Galaxy V311 exe file Click Others when the following screen appears Communication Modes Serial Port T Fast C nwi dobis i J Rainier4a 4d 4a1v 4d1v e fF MCC8001 IP C User Define C Automatically Search Cancel 2 When the following screen appears select Others and on the Module Style drop down menu select MCC 8004 Uthers Module Style MCC 8004 v Clear All File Using Digital Clock Change IP Address Using Analog Clock com ft me 210 10 10 151 Pro 0 f z COMASetup Firmware T FPGA MB Digital Clock 1 FPGA UB Path Browse 4 OSD font Alarm Path Browse 115 3 Click to select the IP checkbox with the factory default 210 100 100 151 value In case you have changed the IP address of your MCC 8004 series then make sure to enter the correct IP address 4 Click to select the FPGA MB Digital Cloc
57. hown in this manual 1 1 Package Contents After unpacking the shipping carton you should find these standard items Re A z Avitech MCC 8004 series Standard Power Cord US customers only DVI Cascading Cable RS 485 Cascading Cable optional when purchasing 2 or more MCC 8004 series optional when purchasing two or more MCC 8004 m RJ 50 GPI Terminal Block Utility Disc contains software and user s manual Set of screws optional Ear already installed on MCC 8004 upon order for assembly on to rack mount 1 2 Product Features e Automatic sensing of HD SDI SD SDI and composite analog input e Up to 26 internal configuration presets e On screen display of labels borders and video alarms e Supports direct TSL Tally UMD interface e Eight GPI for Tally or recall of preset e Communication control via RS 232 or IP e Compatibility with Galaxy software for configuration monitor layout and multiple system control e Avitech ASCII Protocol AAP support e DCDi processing MCC 8004P MCC 8004Q MCC 8004U e Fixed quad split display MCC 8004Q e 32 channels of embedded audio with phase correlation MCC 8004Q e Audio meters for embedded audio with phase AES balanced unbalanced analog audio option NOTE e Embed digital audio streams into high definition digital video signals e AES Audio Engineering Society Officially known as AES3 it is a digital audio standard used for car
58. iGreen f Blu fie al Color Key Lower All C Red C Green Blue 0 4 VGA Gain GAL oC Red Green C Blue fea 4 r Gamma ALL Red Green Blue 1000 gt Cancel Default 3 Select the Image Window then you can adjust the input signal such as Brightness 0 255 Saturation 0 127 Contrast 0 127 Hue 128 127 Color Key Lower All Red Green Blue 0 255 VGA Gain All Red Green Blue 0 255 and Gamma All Red Green Blue 0 523 5 parameters directly by using the sliders or clicking the radio button Click the Default button on the lower right portion of the screen to reset the values to the factory default 91 Audio Delay 1 Inthe Option menu click Check Audio Style Master MCC_8004_d dE dL dEL r COM m 01 Y fi z m Select ID or Add To Other Group Pig ig eis ig os Deis 7 oe wl tf Sg ity oe eile gaeui eamt cs Sub ID ate ao ee whee bene r Image Window amp Label Switch WoL WoL BV Imaget Biv I Image2 aj V M Image 5j M Iv Image4 M PF Images E I T Images E F T Image F T Image Load File Save File Fader Control Adjustment Image Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com4 2 When the following screen appears click the audio Check option Check Audio Source Check Meter MeterMeter2 gt Channel Master Channel x Sound nn gt
59. ile Click Others when the following screen appears Communication Modes Serial Port I Fast c ine Td Hesene J Rainiersa 4d 4alv ddly J mMccso01 P C User Define C Automatically Search Cancel 118 2 When the following screen appears select Others and on the Module Style drop down menu select MCC 8004 Others Module Style MCC 8004 X Clear All File Using Digital Clock Change IP Address Using Analog Clock M COM f aia IP 210 100 100 151 Ping Dh COM A Setup Firmware J FPGA MB Digital Clock Path Browse Path Browse 1 FPGA UB Path Browse OSD font Alarm Path Browse 3 Click to select the IP checkbox with the factory default 210 100 100 151 value In case you have changed the IP address of your MCC 8004 series then make sure to enter the correct IP address 4 Click to select the FPGA UB checkbox then click the Browse button to specify the location of the firmware file and select AT MCC 8004UB DA11 080123 rbf for MCC 8004d Q AT MCC 8004UB AA0126 rbf for MCC 8004aA AT MCC 8004UB PALL0129 08 rbf for MCC 8004P AT MCC 8004UB UALL0213 08 rbf for MCC 8004U Othe Module Style Mecs Clear All File Using Distal Cock Change IP Address Using Analog Clock C com fr jmi 210 100 100 151 Pio 0 fi COMA Setup Firmware 1 FPGA MB Digital Clock Path Browse 1 FPGA MB An
60. ill be shown on the screen This feature is to notify you a problem happened but no one noticed it right away e Video Black to turn on off the video black alarm that is triggered by setting the threshold brightness level of image in relation to the area percent e Signal Type sets the signal s font and background color When this option is enabled the video s signal type will be displayed on the monitor display EE Signal Type 44 Setting Clock Properties NOTE Make sure to turn on all clocks see previous section before setting the clock properties To set the clock properties click Clock to adjust the Font Color B G background Color and font Size for all clocks in the group You can also set the Analog Clock Size Border Hide Switch full screen mode Count up down Font Color Source and Time Zone BMP Label allows you to activate the universal fonts for clock by performing the following steps 1 2 3 Click to enable the BMP Label checkbox with checkmark Click the BMP Label Font Type button When the Font window appears set the Font Font style and Size Then click OK Clock Properties Group M Label Total Characters 32 7 I BMP Label Font Color B G Color Size j1 v LEMP Label Font Type Analog Clock Size 192s A Or IV Border I Hide Switch Fullscreen mode Count uP C DOWN Font Color O Source Freerun Slave
61. k item then click the Browse button to specify the location of the firmware file and select AT MCC 8004MB D 080123 rbf for MCC 8004d Q AT MCC 8004MB D0123 08 rbf for MCC 8004a aA P U g ais i jaMV a _ gt _ Module Style MCC 8004 X Clear All File Using Digital Clock Change IP Address Using Analog Clock COM A Setup 7 FPGAUB Path Browse J OSD font Alarm Path Browse 5 Click the Update button located on the left lower portion of the screen 6 Reboot unplug and re plug the power cord the MCC 8004 series when FPGA MB Digital Clock firmware update is successful NOTE Shutdown and startup of MCC 8004 series needs to be done to completely update the FPGA MB Digital Clock firmware 116 FPGA MB Analog Clock Firmware To update the FPGA MB analog clock firmware perform the following steps 1 Run the Galaxy program by double clicking the Galaxy V311 exe file Click Others when the following screen appears Communication Modes r Serial Port I Fast UserDefie 1 prariertartdsdatvidly J mccsoo1 IP C User Define Automatically Search Cancel 2 When the following screen appears select Others and on the Module Style drop down menu select MCC 8004 Others Module Ste MCC8004 o Clear All File _ Using Digital Clock Change IP Address Using Analog Clock Fee M e room re fo _ amasan
62. lay dynamic labels then click the radio button to select TSL Only If you want to display both the static and dynamic labels click the radio button to select Allow Both Static amp Dynamic 5 To display 8 or 16 dynamic characters in case the TSL implementation allows it click the radio button to select the corresponding options This concludes the TSL setup on the group level 53 For an individual window Perform the above same steps for each window by right clicking the mouse on each individual window then clicking TSL to set the TSL Display Address Size gt Full Screen Select Source VCC 4xD I gt Check Signal Set Label Set Meter Set Border Safe Area UnderScan Set Alarm Aspect Auto Detect TSL NOTE When dynamic labels are displayed bitmap fonts cannot be used for displaying static and or dynamic labels 54 Aspect Auto Detect Allows you to turn on off automatic detection of the input signal s aspect ratio For HD SDI input signal the aspect ratio will be 16 9 for SD SDI composite the aspect ratio default setting is 4 3 Group Reset Meter Label Border Tally Alarm Clock UnderScan COM A TSL Aspect Auto Detect gt on Output Timing gt Off VGA to Background Window Size gt Set Default Layout Output Timing There are two output timings namely Normal and VESA Normal output timing is designed for some brands of monitor display which do not support the VESA standard The
63. lick the mouse on NTP to select it Then click the NTP Properties button and the following screen appears NIP Properties NTP Server EH 43 244 18 Gateway 210 100 100 254 Update Frequency Enter the IP address of the NTP Server the default Gateway use ipconfig in Windows DOS mode to find out then set the time interval that the clock will be updated Select the Time Zone in the drop down menu and click the mouse on the Daylight checkbox to select DST daylight saving time when applicable Click Update on the lower middle portion and then the OK button NOTE You may be required to exit the Galaxy program by first saving the new settings to flash memory then restarting the Galaxy program before the clock can be updated Underscan The technique that allows you to extend the raster the overall area that is scanned by the electron guns closer to the edge of the monitor s bezel is called overscanning The opposite occurrence when the display image is focused toward the middle of the monitor display is called underscanning You may need to use this function when the composite PAL NTSC video source entering the MCC 8004 series causes lines of text appearing on the side any to be cut off Use underscan to allow the cut off portions to be made visible NOTE Be careful when trying to decrease the size of the video image in the viewable area To adjust for this occurrence you need to adjust both the horizontal a
64. mages E F F Images E l T Images x bD v e PE imar E Imager v Load File SaveFile Fader Contvo Se Adjustment Image Trin w _we Position Fine Adjustment Check Audio Set Com4 Cancel Update 4 Ona particular window select Full Screen to maximize the image and fill up the whole screen Select Source Allows you to specify the DVI signal source when cascading with the VCC 8000 series The selected source would have a checkmark v Source 1 Source 2 Source 3 Source 4 75 Check Signal To find out the video signal being fed into the selected window right click the mouse on a particular window and click Check Signal The following screen appears Signal Type x SD_SDI_PAL Turning On Off the Label 1 The Option window has a checkbox that can be used to turn off the label L for each window r COM r Group Select ID or Add To Other Group 9i 8 e es 94 gS GC Gx z ABs Siete 10 E slide if Ie ig VE io is Sub ID Sl igh Ag ee ae 2 m Image Window amp Label Switch WIL WIL F M image1 S IV lv lmage2 5 M M image3 M images HC is E imas Hl fri Image Hl TP image7 Load File Save File F Adjustment Position Fine Adjustment Size Fine Adjustment Check Audio Set Com4 2 To turn off a label find the checkbox that represents the selected window and check to enable or un check to disable the Label 76 3 Upon right
65. make sure that power is available Connect to power Connect to power 1 6 Using the Galaxy Program The Galaxy program is designed to be used with Avitech Multiviewer modules A small yet powerful program it uses very little system resource and will not take up much hard drive space best of all no installation is required This software can be used on your PC or laptop computer and may even be run through an external portable device but should not be run from a read only device such as an optical disc This section introduces the Galaxy program for setting up your system 10 NOTE Make sure the MCC 8004 series is powered on and connected properly to your computer see previous section before launching the Galaxy program To optimize the usage of your Avitech MCC 8004 series perform the following steps to configure it using the Galaxy program l If you will use the network cable IP address to connect configure your computer to the following setting IP address 210 100 100 150 and subnet mask 255 255 255 0 If you will use the serial cable to connect configure your computer s COM port tobe 1 10 If you decide to use the network cable to connect make sure you can ping the module at 210 100 100 151 factory default IP address by clicking on Start gt All Programs Accessories gt Command Prompt The following screen appears BEE Microsoft Windows XP Version 5 1 2666 lt C gt Copyright 1985 2061 Mi
66. mal to Abnormal Joss _ p pa Alarm Lock ja jE T Video Black Threshold Voltage 4 2 Areal al gt IV Signal Type Signal Type Font Color Signal Type BG Color w a 82 Aspect Auto Detect Allows you to set the input signal s aspect ratio of a particular window If the input signal is of a different aspect ratio than the monitor in which it is displayed you may change the monitor s aspect ratio to display the signal without deformation 1 Right click the mouse on a particular window and click Aspect Auto Detect When the next screen appears click the mouse to select Enable and then select the desired aspect ratio Aspect Auto Detect M Enable SD SDI Composite HD SDI 4 3 16 9 f 16 3 Cancel 2 Then click OK The available selection for HD SDI is 16 9 while for SD SDI Composite you can switch between 4 3 and 16 9 Displaying Static Dynamic Labels Allows you to display static dynamic labels by right clicking a particular window select TSL and the following screen appears Refer to a previous section for details on setting the TSL Properties TSL Properties m Enabid Display Address Modes J Fixed Brightness TSL Only C Allow Both Static amp Dynamic Display First 8 Characters C Display All 16 Characters Cancel 83 Saving to a Flash File There are two instances that you will need to use the save to flash feature e Aft
67. mand ZP 0203 list Group 2 third module s presets ACP does not support this command ZR GGMMPP SD width rate SD height rate HD width ratio HD height ratio to lock and adjust the video ratio ZR GGMM01 4 3 16 9 sets GGMMO1 SD video ratio as 4 3 HD video as 16 9 ZR 000000 169 43 sets all windows SD video ratio as 16 9 HD video as 4 3 ZR GGMMPP 7 12 7 12 sets GGMMPP s SD and HD video ratio as 7 12 ZR GGMMPP 0 000 disables the function by setting the width rate or height rate 0 ZT GGMMPP 1 Tally 1 2 Tally 2 1 on 0 off color index number turn on or off the Tally for a window or all the windows in a group The color index number is a list of colors that the Tally can be 110 Description Designate the action of the Tally The following table shows the color index Index Color Red Pink Examples ZT 000000216 activate Tally 2 for all the window s in all the module s for all the group s with pink color ZT 010203 1 0 close Tally 1 for group 1 module 2 window 3 NOTE Upon changing a Tally color the same color is applied to the other Tally of the same module ZV Format ZV GGMMPP volume default 32 range 0 127 Function to set the analog audio s volume level Examples ZV GGMM01 0 turns GGMM s window 1 analog audio to mute ZW Format ZW GGMMPP X position Y position W idth H eight Function to set the window s position and size or appear as
68. n its facility the Product that these products will be free from defects in material and workmanship for a period of one 1 year or twelve 12 months from the date of shipment of the Product to the purchaser If the Product proves to be defective during the one 1 year warranty period the purchaser s exclusive remedy and Avitech s sole obligation under this warranty is expressly limited at Avitech s sole option to a repairing the defective Product without charge for parts and labor or b providing a replacement in exchange for the defective Product or c if after a reasonable time is unable to correct the defect or provide a replacement Product in good working order then the purchaser shall be entitled to recover damages subject to the limitation of liability set forth next Limitation of liability Avitech s liability under this warranty shall not exceed the purchase price paid for the defective product In no event shall Avitech be liable for any incidental special or consequential damages including without limitation loss of profits for any breach of this warranty If Avitech replaces the defective Product with a replacement Product as provided under the terms of this Warranty in no event will the term of the warranty on the replacement Product exceed the number of months remaining on the warranty covering the defective Product Equipment manufactured by other suppliers and supplied by Avitech carries the res
69. nd vertical sizes and phases 47 Click Under Scan and the following screen appears Click the checkbox to enable Is Under Scan then use the slider to set the Left 128 126 Width 34 0 Top 0 18 Height 16 0 Click OK to exit UnderScan AJ a width o gt xl Top fo si I Height Jo a HIE Cancel Default 48 Setting COM Ports By default the COM port is set to normal and baud rate set to 57600 bps to configure the serial port of the module with PC for configuration and control There are two methods for setting COM port To set the COM port perform the following steps 1 Click COM A or on the Option window click Set COM A Style Master MCC_8004_d dE dL dEL m COM Group 01 Y 1 x r Select ID or Add To Other Group 9 lig 2 S e G ir Ee a7 e bets SE T0 Oo wig ito a E S if Sub ID eT ee ats sate Ps Image Window amp Label Switch wW L wW L Bjr M M Imaget Bj V M Image Bjr Iv mates ajv M M Image4 BB ies E M mages ine age EB PW imeace7 Load File Save File Fader Control Adjustment age Trim Position Fine Adjustment Size Fine Adjustment Check Audio SetComs 49 2 The following screen appears Select the Setting COM A option if available Set Serial Port Communication Setting Com ja M R5422 f RS48 Baud Rate 57600 bps A Mode Normal X Detect Slave Module Mode Fast Default v i C
70. ode Label ANSI All FWHWInfo The convenient way is to export the file label as a BMP Label Unicode or Label ANSI txt file by assigning a filename when the next screen appears Save in Temp gt ct EE E all FWHWiInFo TXT Jana File name 27 Save as type Pos File TXT 7 Cancel By using Microsoft Notepad edit the text in the file starting with Group 1 and Module 1 When you are done editing the label highlighted in red next save the txt file and import it The on screen labels will then be updated PD Label TXT Notepad DE Imagel Image2 Image3 Image4 m _ Module 2 comport 1 ID 2 mcc_8004_U UL UE UEL Imagel Image2 Image3 Image4 i f _l _ Module 3 J comport 1 J ID 3 vcec 8004u window window 2 window 3 window 4 System Parameter The following are the items appearing on System Parameter Return Group Index to Default Allows you to return all groups to their default setting as well as combine all modules into one group Click OK when the next screen appears to complete the configuration change WARNING A This action will remove all Group index information All Modules will belong to Group 1 28 One Module Per Group By default the Galaxy program will combine all available modules into one large group To quickly divide modules into different groups each module can be treated as a group For example if casc
71. ollowing steps NOTE Make sure to turn on all labels see previous section before setting the label properties 36 Allows you to adjust the Font Color B G background Color and font Size for all labels in the group Label Properties Group Align Left f Center Total Characters 32 6 37 For an Individual Window 1 Right click the mouse on a window and select Label to enter the text Size gt Full Screen der To Back a gt gt gt VGA Auto Setting gt Check Signal Set Meter Set Border Safe Area UnderScan Crop 1400x1050 50Hz2 Set Alarm Aspect Auto Detect lose Caption Manual Adjustment Source Pos TSL Bring clock logo or ACC UI Window to Top 38 2 Keep in mind that each window supports one line of text up to 32 characters Label Properties Process Align Left Center J BMP Label Total Characters 32 6 OSD Position 0 Line 1 ie ines Lines tS S FontColor _ _B G Color MM size 1 J Label Outside BMP Label Font Type J Fill Background All Process I Text Transparency Switch a Transparency Cancel Update e OSD Position allows you to change the vertical position of the label by clicking above or below the blue line default is 0 e Label Outside allows you to place the label outside the window e Fill Background all
72. own the Galaxy program and save to flash Power off the MCC 8004 series by unplugging the power cord Then plug in the SCP keypad to the rear panel s Keypad port NOTE If you need to connect again using the Galaxy program you must first disconnect the SCP keypad Connect the power cord back to the MCC 8004 series to power on Recalling Presets The MCC 8004 series COM port is automatically set to the following parameters e RS 232 e 8 bit data e 1 stop e No parity e 9600 bps baud rate 95 To recall the presets perform the following steps l 2 To login to the Simple Control Panel mode press Enter Use the Galaxy program s preset files saved in the MCC 8004 series flash memory The preset filename format is X GPY where X 0 26 this refers to preset 0 preset 26 where Y 0 9 this refers to group 0 group 9 Recall preset mode 1 To recall the next preset file press the plus key To recall the previous preset file press the minus key Recall preset mode 2 To recall a specific preset file press the two number keys The first number signifies the Group number the second number signifies the preset number For example pressing the 19 number keys would allow the MCC 8004 series to recall the 9 GP1 preset file Recall preset mode 3 supports recall of preset files 0 26 Example 1 pressing 1 one gt point or period gt 1 one gt Enter total of four keys would
73. ows the label background to fill the entire width of the window e Text Transparency Switch allows you to set the transparency level of the entire label including the background 39 e BMP Label allows you to activate the universal fonts for labels by performing the following steps 1 Click to enable the BMP Label checkbox with checkmark 2 Click the BMP Label Font Type button 3 When the Font window appears set the Font Font style and Size Then click OK 4 On the Line 1 window enter a label in the desired language by first selecting the language on the Windows taskbar Chinese Taiwan v English United States Show the Language bar EN ROAR 3 38 5 Repeat the above steps for all the other windows Setting Border Properties Borders are turned on by default to turn off the border perform the following steps For an Entire Group 1 Upon clicking Border the following screen appears Change the Border Width to 0 Border Properties Group M Enable Linel C Line2 Line3 C Lined C LineS C Line P AllLine Select Color 2 C E mm E Cancel 40 2 You can also change the border color e Each pixel line can have a different color Linel C Lined I AllLine C Line2 C Lines C Lined C Line6 Select Color e 3D border LJ c OW Eo Oo For an Individual Window To chang
74. pective manufacturer s warranty Avitech assumes no warranty responsibility either expressed or implied for equipment manufactured by others and supplied by Avitech This Warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty of merchantability or fitness for a particular purpose all of which are expressly disclaimed This Hardware Warranty shall not apply to any defect failure or damage e caused by improper use of the Product or inadequate maintenance and care of the Product e resulting from attempts by other than Avitech representatives to install repair or service the Product e caused by installation of the Product in a hostile operating environment or connection of the Product to incompatible equipment or e caused by the modification of the Product or integration with other products when the effect of such modification or integration increases the time or difficulties of servicing the Product Any Product which fails under conditions other than those specifically covered by the Hardware Warranty will be repaired at the price of parts and labor in effect at the time of repair Such repairs are warranted for a period of ninety 90 days from date of reshipment to customer Extended Warranty Options Avitech offers OPTIONAL Extended Warranty plans that provide continuous coverage for the Product after the expiration of the Warranty Period Contact an Avitech sale
75. que addresses in systems with two or more units RS 485 in out RS 485 connectors for serial cascading input output 100 250V AC Power jack for connecting the AC power cord 1 5 Getting Your MCC 8004 Series Ready for Use Basic Hardware Connections Perform the following steps to get your MCC 8004 series up and running NOTE The steps outlined next would depend on the type of configuration you wish to set up 1 Connect up to four BNC cables to the four video Input 1 2 3 4 ports for HD SD SDI composite video inputs 2 Connect the RS 232 cable to the RS 232 port for signal from PC 3 Connect the Ethernet cable to the IP port for using the computer s Galaxy program to perform setup on the MCC 8004 series 4 Connect the DVI I cable to the DVI I Out port for video output to the monitor display 5 Make sure to assign a unique address to your MCC 8004 series ID rotary dial when connecting to systems with two or more units 6 Connect the RJ 50 cable to the GPI port for GP input output 7 Connect the AC power cord to the 100 250V AC power jack Cascading To cascade two Avitech MCC 8004 series perform the following steps 1 Set the Rotary ID on the first Avitech MCC 8004 series to 0 and set the Rotary ID on the second Avitech MCC 8004 series to 1 can be other values as long as both are different from each other s setting ID 1 IDO IMPORTANT When cascading two or more modules up to 15 maxim
76. rying digital audio signals between various devices AES was designed primarily to support PCM pulse code modulated encoded audio in either DAT digital audio tape format at 48 kHz or compact disc format at 44 1 kHz Analog audio is superior to digital audio due to the absence of fundamental error mechanisms which are present in digital audio systems including aliasing quantization noise and supposed limitations in dynamic range Specifications GPI Specifications Automatic sensing via BNC HD SDI 1080i 59 94 1080i 60 1080i 50 720p 59 94 720p 60 720p 50 SD SDI NTSC 525i PAL 625i 525p 59 94 625p 50 Composite analog NTSC PAL Number of inputs for MCC 8004a aL aA aAL four automatic detection composite video PAL NTSC for MCC 8004d dL dE dEL dA dAL dD dDL P PL PE PEL PA PAL PD PDL four automatic detection SD SDI composite video PAL NTSC for MCC 8004Q QL four automatic detection HD SD SDI for MCC 8004U UL UE UEL UA UAL UD UDL four automatic detection HD SD SDI composite video PAL NTSC NOTE Input source for 720p supports 60 Hz only Analog AES Embedded Available for MCC 8004aL aAL dL dEL dAL dDL PL PEL PAL PDL QL UL UEL UAL UDL Resolution from 800x600 up to 1920X1200 WUXGA via DVI I connector simultaneous DVI and RGB Number of output 2 Available for MCC 8004aA aAL dA dAL PA PAL UA UAL Available for MC
77. s representative or details on the options that are available for your Avitech equipment Services and Repairs Outside the Warranty Period Avitech make its best offer to repair products that is outside the warranty period provided the product has not reached its end of life EOL The minimum charge for such repair excluding shipping and handling is 200 US dollars Regulatory Information NOTE Marking labels located on the exterior of your device indicate the regulations that your model complies with Please check the marking labels on your device and refer to the corresponding statements in this chapter Some notices apply to specific models only Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet F
78. se button to specify the location of the firmware file and select AT MCC8000 DATA V104 OSD for MCC 8004d Q a aA P U Others Module Style MCC 8004 v Clear All File Using Digital Clock Change IP Address Using Analog Clock F COM fi w MIP 210 100 100 151 Ping ID x COM A Setup Firmware Path _ ny Browse 1 FPGA MB Analog Clock Path Browse T FPGA UB Path Browse J OSDf font Alarm Pa ee 5 Click the Update button located on the left lower portion of the screen 6 Reboot unplug and re plug the power cord the MCC 8004 series when OSD firmware update is successful NOTE Shutdown and startup of MCC 8004 series needs to be done to completely update the OSD firmware 4 2 Resetting to the Factory default State To reset your MCC 8004 series to the factory default state perform the following steps 1 Power off the MCC 8004 series by unplugging the power cord 2 Push the number 2 dip switch located on the MCC 8004 series rear panel downward to the ON position 3 Power on the MCC 8004 series by plugging in the power cord make sure that power is available 4 Push back the number 2 dip switch upward to the default position 121 Glossary DDC Display Data Channel Group screen Latest File Master Module Module File Preset File Rotary ID Selector Switch Slave Module System File VESA st
79. splay s optimum aspect ratio To enable or disable this feature perform the following steps 1 Click Auto Parameter 2 Click Aspect Detect then select On Off default setting is Off Aspect Detect a On off NOTE When the Aspect Detect option is set to On all the presets will be displayed in the optimum aspect ratio Output Timing There are two output timings namely Normal and VESA Normal output timing is designed for some brands of monitor displays which do not support the VESA standard The default setting for output timing is Normal Normal VESA When the item All Clocks under System Parameter is set to On a checkmark appears on this item You can turn on with checkmark or off the clock window display Click on the item to toggle between on off Clock Window Cascade in VGA Only You can turn on with checkmark or off the cascade mode with VGA signal only Click on the item to toggle between on off 57 Activating Tally The RJ 50 to GPI terminal block allows for a total of eight inputs to activate Tally two per window You can also use the serial port with ASCII TSI or TSL to activate the Tally To change the appearance of the Tally perform the following steps 1 Click Tally and the following screen appears Tally Properties Module V Clear Tally status M Show Set Tally Color G Tally c tay2 Rc tava LED 1 LED 2 LED 3 T Flash Set GPI Serial Tally Event GPI GPI 1 M LED1 M Label
80. t Settings Special Screen Layout Help 2x2 4 3 3x3 3x4 4x3 4x4 5x5 Image3 Repositioning an Individual Window To reposition a window perform the following steps 1 Drag the center of a window and drop to a new position and it will update on the monitor display Or 71 Option Window 2 Use the Position Fine Adjustment menu to adjust the position of any window in a pixel by pixel basis Keep in mind that the width increases in 16 pixel increments and the height in 1 pixel increments Style Master MCC_8004_d dE dL dEL COM Group 01 Y 1 z r Select ID or Add To Other Group oi ge 28 eo big Fs fc Bote ay ars iets Coe te ant Blige Pas eh it ia als Position Fine Adjust Select Image Window Jp Sub ID caj c a a cel ca cmc aS Ea CIRI EA m Image Window amp Label Switch wW L wo BM Mimaget et MM Image2 a Vv Image3 a M I Image4 Bi T I Images Bi M V Image T VF image il M WT Image Load File Save File Adjustment Image Trim Size Fine Adjustment Check Audio Set Com Fader Control 72 Mouse Right click Menu To change the properties of an individual window right click the mouse on the particular window to access the window s menu Size gt Full Screen Select Source VCC 4xDYI gt Check Signal Set Label Set Meter Set Border Safe Area UnderScan
81. ule Layout 14 e Galaxy control window is for creating and configuring the layout fae Avitech Galaxy 1280x1024 60Hz Baud 57600 bps Select Settings Special Screen Layout Help Image1 Image4 Image3 On the blue information bar portion can be found the following items Logo icon Avitech Galaxy proprietary logo and the name of the software 1280x1024 60Hz shows the current output resolution and frequency Baud 57600 bps shows the current COM port baud rate 15 e Option window is for group and window label setup save load file adjust image monitor audio and COM port setting Refer to a later section for details COM Group i A 7 a r Select ID or Add To Other Group o9il 2 se So 4b op 5 if Gio ei ORE El igh ify m Sub ID GIE m Image Window amp Label Switch w L wW L BALM M image E V Image2 5j M Image Bl M Iv Image4 BH T PF Images Bi F T Images T T image E VT T Image Load File Save File Fader Control Adjustment Image Trim Position Fine Adjustment Size Fine Adjustment Check Audio Set Com 16 9 Right click the mouse on the blue information bar to access the Group Layout menu Select from 2x2 up to 10x10 as possible grid positions on the monitor display NOTE The layout size available for your particular model will depend on the monitor display s resolution as well as the smallest window size limitation MCC 8004 series
82. um make sure each module gets assigned a unique rotary ID or it will cause input conflicts 2 Connect one end of DVI cable to the DVI I Out port of MCC 8004 series ID 0 and the other end to the Cascade In port of MCC 8004 series ID 1 ID 1 DVI output ID 0 to DVI cascade ID 1 RS232 IDO 3 Connect one end of the RS 485 cable to the RS 485 out port of MCC 8004 series ID 0 and the other end to the RS 485 in port of MCC 8004 series ID1 4 Connect one end of the DVI cable to the DVI I Out port of MCC 8004 series ID 1 and the other end to the monitor display IDO Or for monitor display with VGA input connect one end of the VGA cable to the Analog Out port of MCC 8004 series ID 1 and the other end to the monitor display Connect to monitor display IDO 5 Connect one end of the RS 232 cable to the computer s RS 232 port and the other end to the RS 232 port of MCC 8004 series ID 0 ID 1 Connect to computer IDO 6 Ifthe computer application uses multimedia input connect one end of the DVI cable to the computer s DVI port and the other end to the Cascade In port of MCC 8004 series ID 0 ID 1 IDO Connect to computer 7 Ifyou need to use the Galaxy program to perform setup connect the network cable between the MCC 8004 series ID 0 IP port to the computer s RJ 45 port ID 1 Connect to computer IDO 8 Connect the power cables to the two MCC 8004 series and
83. ures Using the latest DCDi technology from Faroudja DCDI is a video mode algorithm that stands for Directional Correlation De interlacing Its function is to help optimize full screen mode regardless of the input format Your MCC 8004 series can be used as a standalone unit or cascaded daisy chained with ACC 8000 or VCC 8000 series modules to provide highly complex monitoring applications up to 15 modules NOTE No DVI cascade is available for the MCC 8004Q About this Manual This manual contains comprehensive information of your Avitech MCC 8004 series to help you operate the device Throughout the manual the following conventions are used to distinguish elements of text NOTE provides additional hints or information that requires special attention CAUTION identifies important information which if not followed may result in loss of data or damage to your device Any name of menu command icon or button that you can see on the screen is shown in a bold typeset For example On the Start menu select Settings Getting Started This chapter introduces you to the features and specifications as well as the external components of your Avitech MCC 8004 series It also guides you through the process of setting up your MCC 8004 series for use NOTE e MCC stands for Media Control Center e Depending on the model you purchased the cabinet color and the look of the accessories may be different from the ones s

Download Pdf Manuals