Home
MAC Aura XB user manual
Contents
1. Menu Item Options Notes Default settings in bold print VERSION CPU firmware version RESETTABLE Hours of operation since counter reset POWER ON TOTAL Total hours of operation since manufacture RES CLEAR RESETTABLE Reset resettable counter to zero CURRENT Display current main PCB temperature MAIN PCB SINCE RESET Display highest main PCB temperature since last reset TEMP MAX Display highest main PCB temperature since manufacture CURRENT Display current average Beam LED temperature INFO BEAM LED RESET Display highest average Beam LED temperature since TEMP last reset MAX Display highest average Beam LED temperature since manufacture CURRENT Display current average Aura LED temperature AURA LED RESET Display highest average Aura LED temperature since last TEMP reset MAX Display highest average Aura LED temperature since manufacture SERIAL ee SERTAI Display fixture s RDM ID NUMBERS NUMBER Display fixture s serial number TEST ALL Test LEDs pan tilt zoom and display TEST TEST LEDS Test LEDs only TEST MOTORS Test pan tilt and zoom movement only TEST DISPLAY Test all segments in onboard display panel RATE XX Hz DMX transmission speed live in packets per second QUALITY 0 100 Percentage of packets received with errors live DMX LIVE START CODE 0 255 Decimal value of DMX start code live Scrolls through DMX value received on each DMX BEAM SHUT 0 255 channel AURA BLUE
2. Electronic with regular and random pulse burst and strobe effects Pre programmed effects Range of independent and synchronized Beam and Aura FX two combinable Electronic dimming Independent Beam and Aura four dimming curve options LOW ss id Ge ese ee aaa la ee ee ee 2 11 53 one tenth peak angle O AAN 540 MMU see eh SE Egg eae yep say von res eee toe E oh es ei asus an 232 Pan and tilt speed Adjustable via onboard control panel and DMX Optics and Photometric Data Fight SSBICOu sz uyu aa iii bsk taa dia 15 W RGBW array system LED refresh Tate smart aid ata arta rada ds Beam 1200 Hz Aura 4395 Hz Minimum LED lifetime 50 000 hours to gt 70 luminous output Total luminous output wide one tenth peak o oo oooocoooorno eee ees 4 6 klm Total luminous output narrow one tenth peak 3 8 klm Video compatibilily Designed for use with HD high speed video cameras Manufacturer s figure obtained under manufacturer s test conditions Control and Programming COnHIGLODUS0S 4 fen ccnde ee eke eeu ee eee ld Independent or synchronized Beam and Aura control CONUOUSVSICINGS 2 2d dad daa cdas DMX RDM Control FESOMMON tas laca St eae Eek ee eek et tees as 8 bit with 16 bit control of pan amp tilt Bs Seles are le a k ieee giant tn nas 14 25 S
3. 232 s tee Tilt fine 7 0 255 O 100 Tilt fine adjustment Least Significant Byte r aqo 3209 Table 2 MAC Aura XB DMX Protocol DMX protocol 23 24 Channel DMX Fade Default Std Ext value Percent Function status value Fixture control settings 0 9 0 3 No function 10 14 4 5 Reset entire fixture 15 39 6 13 No function 40 44 14 15 PTSP NORM 45 49 16 17 PTSP FAST 50 54 18 19 PTSP SLOW 55 59 20 21 No function 60 64 22 23 Fan mode FULL 65 69 24 25 No function 70 74 26 27 Fan mode REGULATED 75 89 28 33 No function 90 94 34 35 RGB color mode fully calibrated color output same gamut for all MAC Aura XBs 95 99 36 37 EXTENDED color mode calibrated white point with extended color saturation saturated colors may not be exactly identical 100 104 38 40 RAW color mode compatible with standard MAC Aura fixtures max output set to standard MAC Aura level 105 109 41 42 No function Snap 0 110 114 43 44 Fast dimming speed of intensity changes unrestricted 115 119 45 46 No function Smooth dimming speed of intensity changes restricted 120 124 47 48 slightly 125 129 49 50 No function 130 134 51 52 Video dimming instant intensity changes optimized for video 135 249 53 97 No function 250 255 98 100 Illuminate display 11f DMX Reset is disabled in the menu a reset command can only be executed if channel 2 is set to 232 and channel 1 is set to zero
4. the temperature sensor on the main PCB in the head measures that temperature is too high Power to the LEDs is cut off BEAM TMP CUT OFF RDM message Lamp Temp Cut Off the Beam LED temperature sensor measures that LED temperature is too high Power to the LEDs is cut off AURA TMP CUT OFF RDM message Lamp Temp Cut Off the Aura LED temperature sensor measures that LED temperature is too high Power to the LEDs is cut off Check that ambient temperature is not too high Check that the fixture is clean Check that there is free airflow around the fixture Contact Martin service for assistance PAN FBACK ERR TILT FBACK ERR there is a malfunction in the optical pan or tilt monitoring feedback circuit e g sensor defective After a time out pan or tilt stops in a random position Reset fixture Contact Martin service if problem continues PAN SENSOR ERR TILT SENSOR ERR DRIVER CURR ERR there is a malfunction in the electrical indexing circuit for pan tilt or one of the drivers After a time out the fixture will establish a mechanical stop and continue to work normally Reset fixture Contact Martin service if problem continues VOLTAGE ERR RAM ERROR there is a voltage or RAM error Reset fixture Contact Martin service if problem continues EFFECTS TOO COLD the onboard thermostat measures that the effects are too cold Leave fixture powered
5. Brouilleur du Canada en fonctionnement mer I Peut tre dangereux pour les This Class A digital apparatus meets all requirements of the Canadian Interference Causing yeux conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du Reglement sur le Mat riel Brouilleur du Canada Disposing of this product Martin products are supplied in compliance with Directive 2012 19 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products 36 MAC Aura XB user manual OPERATING amp ASSEMBLY INSTRUCTION NAC3MX W powerCON TRUE1 A OPERATING INSTRUCTION Application The powerCON TRUE 1 system is certified as connector with breaking capacity according IEC 60320 VDE 0625 It is intended for use as appliance couplers and interconnection couplers lt serves to supply power to an appliance and from an appliance to another equipment To be installed by qualified person only Connector Assignment APPLIANCE APPLIANCE INLET APPLIANCE OUTLET IN
6. MAC Aura XB User manual y Martin by HARMAN Dimensions All dimensions are in millimeters NIN PAN AN I 222 lt 270 270 TWA I A ANY E u 302 2011 2014 Martin Professional ApS Information subject to change without notice Martin Professional and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trade marks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries Martin MAC Aura XB products are covered by one or more of these patents US 7 498 756 and or one or more of these patent applications PCT DK2011 050040 US 13 176 137 PCT DK2011 050120 PCT DK2011 050110 PCT DK2011 050112 DK PA 2011 00665 DK PA 2011 00666 and or one or more of these licensed patents US 6 806 659 US 6 150 774 US 6 788 011 US 6 016 038 and or one or more of these designs CN 201130210674 1 CN 201130210696 8 EU 001886888 US 29 396 683 US 29 396 684 and or one or more other intellectual property rights including one or more intellectual property rights listed on www martin com ipr P N 35000280 R
7. AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Safety Information 3 Socket outlets used to supply MAC Aura XB fixtures with power or external power switches must be located near the fixtures and easily accessible so that the fixtures can easily be disconnected from power Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other component is damaged defective deformed wet or showing signs of overheating Do not reapply power until repairs have been completed Connect only a cable with a Neutrik PowerCON TRUE1 NAC3FX W connector to the power input socket Connect only a cable with a Neutrik PowerCON TRUE1 NAC3MX W connector to the power throughput socket Suitable connectors are available from Martin see Accessories on page 35 All power input cables used to connect the product to AC power and all power throughput cables used to connect fixtures to each other so that they draw AC power in a chain must be minimum 14 AWG or 1 5 mm 16 amp rated and temperature rated to suit the application In the USA and Canada cables must be UL listed type SJT or equivalent In the EU cables must be type HO5VV F or equivalent Suitable cables with Neutrik Po
8. DMX values received on FX and Aura control channels only appear in list when fixture is set to EXT mode P T ON Enable pan tilt position feedback correction system FEEDBACK OFF Disable pan tilt feedback for servicing this setting is not SERVICE saved when fixture is reset PAN OFFSET Pan calibration CALIBRATION TILT OFFSET Tilt calibration Table 4 Control menu Onboard control menus 31 Display messages Message Appears when What to do the fixture is indexing effects at startup RST Reset SRST Serial reset the fixture has received a reset command Wait for reset to complete Wait for reset to complete Note that you can set PERSONALITY DMX RESET to OFF to prevent accidental DMX reset commands MEMORY ERROR the EEPROM memory cannot be read Reset fixture Contact Martin if problem persists MAIN TMP SEN ERR RDM message Head Temp Error tHhere is a malfunction in the temperature sensor circuit in the main PCB in the head Contact Martin service for assistance BEAM TMP SEN ERR RDM message Lamp Temp Error there is a malfunction in the Beam LED temperature sensor circuit Contact Martin service for assistance AURA TMP SEN ERR RDM message Lamp Temp Error there is a malfunction in the Aura LED temperature sensor circuit Contact Martin service for assistance MAIN TMP CUT OFF RDM message Lamp Temp Cut Off
9. Medium Blue 65 69 24 25 LEE 200 Double CT Blue 70 74 26 27 LEE 161 Slate Blue 75 79 28 29 LEE 201 Full CT Blue 80 84 30 31 LEE 202 Half CT Blue 85 89 32 33 LEE 117 Steel Blue 90 94 34 35 LEE 353 Lighter Blue 95 99 36 37 LEE 118 Light Blue 100 104 38 39 LEE 116 Medium Blue Green 105 109 40 41 LEE 124 Dark Green 110 114 42 43 LEE 139 Primary Green i 22 115 119 44 45 LEE 089 Moss Green Snap 120 124 46 47 LEE 122 Fern Green 125 129 48 49 LEE 738 JAS Green 130 134 50 51 LEE 088 Lime Green 135 139 52 53 LEE 100 Spring Yellow 140 144 54 55 LEE 104 Deep Amber 145 149 56 57 LEE 179 Chrome Orange 150 154 58 59 LEE 105 Orange 155 159 60 61 LEE 021 Gold Amber 160 164 62 63 LEE 778 Millennium Gold 165 169 64 65 LEE 135 Deep Golden Amber 170 174 66 67 LEE 164 Flame Red 175 179 68 69 Open Color wheel rotation effect 180 201 70 78 Clockwise fast slow 202 207 79 80 Stop this will stop wherever the color is at the time 208 229 81 89 Counter clockwise slow fast 230 234 90 91 Open Random color 235 239 92 93 Fast 240 244 94 95 Medium 245 249 96 97 Slow 250 255 98 100 Open Aura red 23 0 255 0 100 Redd gt 100 Page ae Aura green 24 0 255 0 100 Green 0 gt 100 page ae Aura blue 25 0 255 0 100 BlueO0 gt 100 none an Table 2 MAC Aura XB DM
10. Pan and tilt on the MAC Aura XB are calibrated at the factory so that movement is identical in multiple fixtures Adjustment should not be necessary initially but over a period of use fixtures may gradually lose calibration If re calibration is necessary 1 Pan calibration is easiest when multiple fixtures are stacked vertically To calibrate set tilt positions for easy one over the other comparison and set each fixture to the same pan DMX value Select one fixture to be the reference fixture On that fixture select SERVICE gt CALIBRATION PAN OFFSET and press Wait for the fixture to move to its pan calibration position 2 On each of the other fixtures select SERVICE gt CALIBRATION gt PAN OFFSET and press gt Wait for the head to move to the pan calibration position then adjust the pan offset using the 4 and VY buttons as necessary to align the beam with the reference beam Press gt to save the setting then to exit 3 Tilt calibration is easiest when multiple fixtures are arranged side by side horizontally To calibrate set pan positions for easy side by side comparison Select one fixture to be the reference fixture On that fixture select SERVICE gt CALIBRATION gt TILT OFFSET and press Wait for the fixture to move to its tilt calibration position 4 On each of the other fixtures select SERVICE gt CALIBRATION gt TILT OFFSET and press gt Wait for the head to move to the tilt calibration position then adjust
11. Safety wire safe working load 50 kg P N 91604003 Specifications 35 Flightcase 6 unit flightcase for MAC Aura P N 91515020 Related Items Martin USB Duo DMX Interface Box o ooooooocoon eens P N 90703010 Martin DMX 5 3 Splitter 226 cee das ar A A essa E P N 90758140 Martin RDM 5 5 Splitier coria ds ds dvds ash uw usakama asla W kq amu koq Qa P N 90758150 Ordering Information MAC Aura XB in cardboardbox P N 90232100 MAC Aura XB in 6 unit flightcase P N 90232110 Specifications subject to change without notice For the latest product specifications see www martin com Photobiological Safety Warning CAUTION Possibly h q The label shown on the left is displayed on this product If it becomes difficult or impossible to read ossibly hazardous optical radiation emitted from it must be replaced using the illustration on the left to reproduce a new label this product Do not look at operating lamp I May be harmful to the eyes FCC Compliance GROUPE DE RISQUE 2 This device complies with Part 15 of the FCC Rules Operation is subject to the following two ATTENTION Des radiations lumineuses potentiellement o all MESS Canadian Interference Causing Equipment Regulations R glement sur le Mat riel Ne pas regarder le projecteur
12. Table 2 MAC Aura XB DMX Protocol DMX protocol 25 Channel DMX Fade Default Std Ext value Percent Function status value FX2 adjust 0 255 O 100 Zero gt maximum j 18 e If no sync set on channel 19 adjusts FX2 FONE 128 e If sync set on channel 19 has no effect Sync FX synchronization 0 49 O 19 No sync e FX1 and FX2 run through cycles independently e Cycle duration is regular e Channel 16 and channel 18 adjust FX1 and FX2 independently 50 20 Sync e FX1 and FX2 run through cycles in sync e Cycle duration is regular e Channel 16 adjusts overall speed channel 18 has no effect 51 169 21 66 Sync shift e FX1 and FX2 run through cycles in sync _ 19 e FX2 is offset delayed relative to FX1 Snap 0 e Offset is adjustable from zero maximum e Channel 16 adjusts overall speed channel 18 has no effect 170 209 67 81 Sync random e FX1 and FX2 run through cycles in sync e Cycle duration for synchronized FX1 and FX2 is made shorter and longer at random e Channel 16 adjusts overall speed channel 18 has no effect 210 255 82 100 No sync random e FX1 and FX2 run through cycles independently e Cycle duration is for FX1 and FX2 is made shorter and longer at random e Channel 16 and channel 18 adjust FX1 and FX2 speed independently Aura control Aura shutter and strobe effect 0 19 0 7 Shutter closed 20 24 8 9 Shutter open 25 64 10 25 Strobe 1 fast slow 65 69 26 27 Shutter open 70 84 28 33 Strobe 2 o
13. These values need to be held for 5 seconds before feature is activated Values must be snapped to to function Menu override setting unaffected by power off on Value must be held for 3 seconds to activate Setting unaffected by power off on Table 2 MAC Aura XB DMX Protocol MAC Aura XB user manual Channel DMX Fade Default Std Ext value Percent Function status value Beam color wheel effect 0 9 0 2 Open RGBW color mixing enabled 10 14 3 4 LEE 790 Moroccan pink 15 19 4 5 LEE 157 Pink 20 24 6 7 LEE 332 Special rose pink 25 29 8 9 LEE 328 Follies pink 30 34 10 11 LEE 345 Fuchsia pink 35 39 12 13 LEE 194 Surprise pink 40 44 14 15 LEE 181 Congo Blue 45 49 16 17 LEE 071 Tokyo Blue 50 54 18 19 LEE 120 Deep Blue 55 59 20 21 LEE 079 Just Blue 60 64 22 23 LEE 132 Medium Blue 65 69 24 25 LEE 200 Double CT Blue 70 74 26 27 LEE 161 Slate Blue 75 79 28 29 LEE 201 Full CT Blue 80 84 30 31 LEE 202 Half CT Blue 85 89 32 33 LEE 117 Steel Blue 90 94 34 35 LEE 353 Lighter Blue 95 99 36 37 LEE 118 Light Blue 100 104 38 39 LEE 116 Medium Blue Green 105 109 40 41 LEE 124 Dark Green 110 114 42 43 LEE 139 Primary Green 9 115 119 44 45 LEE 089 Moss Green Snap 0 120 124 46 47 LEE 122 Fern Green 125 129 48 49 LEE 738 JAS Green 130 134 50 51 LEE 088 Lime Green 135 139 52 53 LEE 100 Spri
14. UL 1573 WS ENO Seis a cee ho eee eee ceed eee eRe eee be ee abe shee aes eed Se FCC Part 15 Class A Canadian safely CSA E598 2 17 CSA E60598 1 Canadian EMO u u ot s u iu eee hee eee ee ee ae eee p eee Sees aS ICES 003 Class A Austala NZ seised bined uka u desde deter de ua pradera rr C TICK N4241 Included Items M12 bolt suitable for use with Martin rigging clamps Note that power cables and connectors are not included and must be ordered separately Accessories Power cables Power input cable 16 A 14 AWG SJT 1 5 mm HO5VV F with PowerCON TRUE1 NAC3FX W female power IN connector 3 m 9 8 ft P N 11541513 Power relay cable 16 A 14 AWG SJT 1 5 mm HO5VV F with PowerCON TRUE1 male OUT THRU and female IN connectors 3 m 9 8 ft P N 11541512 Power connectors Cable connector power IN PowerCON TRUE1 NACSFX W P N 05323416 Cable connector power OUT THRU PowerCON TRUE1 NAC3MX W P N 05343418 Note that the fourth digit as well as the last digit is different between these two part numbers Installation hardware Set of 5 x quick mount surface mounting brackets wide P N 91606018 E lsi s PPS E E SS S SSS P N 91602003 Half co pler Clamp lt lt 4424ic20 ncb42ieeee Sete dar dekri yrr dee P N 91602005 Quick trigger clamp 245 2 ako sees on ee eee eee eee Es a s e a G hh Q Q s wu P N 91602007
15. accessories from Martin see Figure 3 Rigging clamp bolt Accessories on page 35 An omega bracket is not required 3 Check that the rigging clamp is undamaged and can bear at least 10 times the weight of the fixture Fasten the clamp to the fixture with a minimum grade 8 8 steel M12 bolt in the threaded hole in the center of the base of the fixture The bolt must protrude 20 30 mm 0 8 1 2 ins into the base of the fixture 4 Block access under the work area Working from a stable platform hang the fixture on the truss with the arrow on the base towards the area to be illuminated Tighten the rigging clamp 5 Secure the fixture against clamp failure with a secondary attachment such as an approved safety cable that is rated for the weight of the fixture and all attached accessories and hardware using one of the attachment points at the edges of the base see Fixture overview on page 7 Do not use any other part of the fixture as a safety cable attachment point 6 Check that the head will not collide with other fixtures or objects y max 30mm Suspending the fixture In some regions it may be legal to use two safety cables one looped through one cable attachment point see Fixture overview on page 7 and the other looped through the other cable attachment point to suspend the fixture If one cable fails the other will provide secondary attachment However this suspension method is not recommended as it will
16. first channel used to receive instructions from the controller For independent control each fixture must be assigned its own control channels Two MAC Aura XB fixtures of the same type may share the same address however if identical behavior is desired Address sharing can be useful for diagnostic purposes and symmetric control particularly when combined with the inverse pan and tilt options The DMX address is configured using the DMX ADDRESS menu in the control panel The highest address that you can select is automatically limited to make sure that enough channels are available for the fixture taking into account the mode that it is set to within the 512 channels available in one DMX universe Beam Aura and FX control STD and EXT modes DMX control mode is selected in the CONTROL MODE menu The MAC Aura XB has two DMX control modes e STD standard mode uses 14 DMX channels 14 MAC Aura XB user manual e EXT extended mode uses 25 DMX channels Standard mode When the MAC Aura XB is set to STD standard mode the Beam DMX channels 1 14 control the output of both the Beam and the Aura The behavior of the Beam and Aura are identical Extended mode When the MAC Aura XB is set to EXT extended mode e Independent control of the Beam is available on channels 1 14 e A range of FX pre programmed effects with combined Beam and Aura output is available on channels 15 19 e Independent control of the Aura is a
17. not hold the base firmly and moving pan and tilt will cause the fixture and light beam to swing uncontrollably Instead we strongly recommend installation using a rigging clamp as described above Warning If you choose to suspend using two cables anyway you must install a minimum 8 8 grade steel M12 bolt in the rigging clamp hole in the center of the fixture s base See Figure 3 The bolt must protrude 20 30 mm 0 8 1 2 ins into the base If you do not secure the base in this way there is a risk that the fixture may separate from the base and fall Quick mount surface mounting bracket Quick mount surface mounting brackets for the MAC Aura XB are available from Martin in sets of five that include hardware and safety cables P N 91606017 The bracket can be screwed to a surface and the MAC Aura XB can be mounted on and removed from the bracket in seconds The MAC Aura XB is a tight fit in the surface mounting bracket Make sure that the fixture is securely clipped into the bracket and always secure the fixture with the safety cable supplied with the bracket Installation instructions are supplied with the brackets Physical installation 13 Setup Warning Read Safety Information on page 3 before installing powering operating or servicing the MAC Aura XB Control panel and menu navigation The onboard control panel and backlit graphic display are used to set the MAC Aura XB s DMX address configure individual fixture s
18. on again and check that the fixture now resets correctly Service and maintenance 21 Fixture readouts DMX input signal The DMX LIVE menu lets you view the DMX values received on each channel in the mode STD or EXT it is currently set to If the fixture does not behave as expected reading the DMX values can help you troubleshoot the problem Fixture status The MAC Aura XB gives fixture status readouts in the INFO menu e Current software firmware version information e Temperature readouts from the main PCB as well as the Beam LED and Aura LED PCBs In each case you can view the current temperature and the maximum temperature reached since the readout was last reset The maximum temperatures can be reset individually The MAX temperature counters are not resettable e Power on hours You can view the number of hours since the resettable counter was last reset or the total number of hours since manufacture You can also reset the resettable counter to zero e The manufacturer s serial number and the fixture s RDM ID number Display messages If an error occurs the MAC Aura XB gives fixture status readouts in the display See Display messages on page 32 Lubrication 22 In general the MAC Aura XB does not require lubrication However depending on use conditions the moving parts in the pan and tilt mechanisms may eventually require reapplication of lubricant Excessive noise during pan tilt movement is a sign t
19. plug in output connector of the last fixture on the link Check addressing on fixture and controller Check fixture is set to correct DMX mode Unplug XLR in and out connectors and connect them directly together to bypass one fixture at a time until normal operation is regained Have faulty fixture serviced by Martin service technician Install a phase reversing cable between the fixtures or swap pins 2 and 3 in the fixture that behaves erratically Clean the fixture especially air vents Ensure free airflow around fixture Check that ambient temperature does not exceed max permitted level Switch to FULL cooling mode If problem persists contact Martin for advice 33 Specifications 34 Physical A RR RR ORAR 302 mm 11 9 in across yoke A w am ua Oe S aS anata ORNS a Se CO a sa biaya q 302 mm 11 9 in across yoke A a Sead suyun aE een en ku aa Za ae 360 mm 14 2 in head straight up Weg senise napu qpuma wa paru puis iio amunka Qa 6 0 kg 13 3 lbs without accessories Dynamic Effects Beam GO OP IWIIXINOS iras AAA AAA AAA eS Ee RR RA a RA RGBW Aura secondary lens array illumination color mixing RGB Beam color temperature control CTC variable 10 000 2500 K Beam and Aura electronic color wheel effect 33 LEE referenced colors plus white variable speed color wheel rotation effect and random color Beam and Aura independent shutter effects
20. the fixture can be moved Warning If the MAC Aura XB can cause injury or damage it if falls attach an approved safety cable to one of the safety cable attachment points on the base see Fixture overview on page 7 Warning Check that all surfaces to be illuminated are minimum 1 m 3 ft 4 in from the fixture that combustible materials wood fabric paper etc are minimum 200 mm 8 in from the fixture that there is free airflow around the fixture and that there are no flammable materials nearby Warning Make sure that it is impossible for the moving head to collide with another fixture or other object Allow a minimum center to center distance of 300 mm 12 ins between MAC Aura XB fixtures Warning Do not expose the front glass to sunlight or other strong light sources Figure 2 Risk of sunlight damage See Figure 2 If light from the sun or other fixtures hits the front glass directly or at an angle it can cause damage inside the fixture or around the edge of the front glass Strong sunlight can cause damage within seconds Before the fixture is exposed to sunlight or strong light shield the front glass or point the head in the opposite direction to the light source Fastening the fixture to a flat surface The MAC Aura XB can be fastened to a stage or other flat surface Check that the surface can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surfa
21. the tilt offset using the lt A and Y buttons as necessary to align the beam with the reference beam Press to save the setting then to exit Software upload The MAC Aura XB is loaded with both software that can be installed and updated by the user and firmware that is internal and accessible to Martin Service and its authorized partners only Software updates are available from the Martin website and can be installed with a PC and Martin USB Duo DMX Interface box that can upload software to one fixture at a time The following are required in order to install software e The latest version of the MAC Aura XB software available for download free of charge from the Product Support area of the Martin website at http www martin com e APC running Windows 7 and Vista 32 64 bit and Windows XP SP3 32 bit e The Windows based Martin Uploader application available for download free of charge from the Downloads Area of the Martin website at http www martin com e Martin USB Duo DMX Interface Box with its supplied cables Installing software normal method 1 Connect the Uploader hardware to a MAC Aura XB fixture s data input connector 2 Upload the fixture software as described in the uploader s help file or user documentation 3 Disconnect the Uploader hardware and reconnect the fixture to the DMX link 4 Cycle power off and on Check that the fixture resets correctly If an error message appears in the display cycle power off and
22. unobstructed airflow around the fixture Do not illuminate surfaces within 1 m 3 ft 4 in of the MAC Aura XB Do not expose the front glass to sunlight or any other strong light source from any angle Lenses can focus the sun s rays inside the fixture creating a potential fire hazard Do not attempt to bypass thermostatic switches or fuses Do not modify the fixture in any way not described in this manual or the product s User Guide or install other than genuine Martin parts Do not stick filters masks or other materials onto any lens or other optical component Use only accessories approved by Martin to mask or modify the light beam PROTECTION FROM EYE INJURY e Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may concentrate the light output Do not operate the fixture with missing or damaged covers shields or any optical component To minimize the risk of eye irritation or injury disconnect the fixture from power at all times when the fixture is not in use and provide well lit conditions to reduce the pupil diameter of anyone working on or near the fixture MAC Aura XB user manual PROTECTION FROM INJURY Fasten the fixture securely to a fixed surface or structure when in use The fixture is not portable when installed When clamping the fixture to a truss or other supporting structure at any other angle than with the yoke hanging vertically downwards use a half co
23. 6 bit control byte In other words the fine channel works within the position set by the main channel Controlling color Color wheel effects The electronic virtual color wheel effects available for the Beam and the Aura give the convenience and feel of a mechanical color wheel and let you snap between 33 different full LEE referenced color presets You can also scroll continuously forwards or backwards through the colors or display random colors at variable speed The approximate RGB equivalents of the color wheel colors are given in LEE colors and RGB equivalents on page 29 Operation and effects 17 18 Color wheel priority The color wheel effect channels for the Beam and Aura have priority and override any color set on the Beam RGBW channels or on the Aura RGB channels To use the RGBW and RGB channels you must set the color wheel effect channel for Beam or Aura respectively to a DMX value from 000 009 If you set either color wheel channel to a DMX value above 009 the color wheel effect overrides RGBW or RGB control RGBW and RGB control RGBW in raw mode or RGB in calibrated mode color control is available for the Beam and RGB control is available for the Aura To obtain consistent color output at different intensities do not use the RGBW or RGB channels to control overall intensity Instead set the desired color on the RGBW or RGB channels then use the dedicated Beam dimmer and Aura dimmer channels to cont
24. 9 Reserved n a Zoom color offset 160 162 Color zoom ramp in Speed 163 165 Color zoom ramp out Speed 166 168 Color zoom fade in Speed Zoom FX 169 171 Color zoom fade out Speed 172 174 Reserved n a 175 177 Zoom ramp up Speed 178 180 Zoom ramp down Speed 181 219 Reserved n a Reserved 220 255 86 100 Reserved n a Table 3 FX pre programmed Beam and Aura effects The MAC Aura XB Product Support page on www martin com features a downloadable detailed description of the parameters that are adjusted and algorithms that are applied in the different FX MAC Aura XB user manual LEE colors and RGB equivalents The table below gives approximate RGB equivalents for the LEE colors available in the standard MAC Aura XB s color wheel effects for the Beam on DMX channel 9 in STD and EXT modes and Aura on DMX channel 22 in EXT mode only Lee no 790 157 332 328 345 194 181 071 120 079 132 200 161 201 202 117 353 118 116 124 139 089 122 738 088 100 104 179 105 021 778 135 164 Name Moroccan Pink Pink Special rose Pink Follies Pink Fuchsia Pink Surprise Pink Congo Blue Tokyo Blue Deep Blue Just Blue Medium Blue Double CT Blue State Blue Full CT Blue Half CT Blue Steel Blue Lighter Blue Light Blue Medium Blue Green Dark Green Primary Green Moss Green Fern Green JAS Green Lime Green Spring Yellow Deep Amber Chrome Orange Orange Gold Amber Millennium Gold Deep Golden A
25. A on 1 888 tech 180 Respect all locally applicable laws codes and regulations when installing operating or servicing the fixture Install operate and service Martin products only as directed in their user documentation or you may create a safety hazard or cause damage that is not covered by product warranties Refer any service operation not described in this manual to an authorized Martin service technician Do not try to carry out any such operation yourself as doing so may present a health or safety risk lt may also cause damage or malfunction and it may void your product warranty Before you install operate or service the MAC Aura XB check the Martin website and make sure that you have the latest user documentation for the fixture Document revisions are indicated at the bottom of page 2 The latest versions of the product s user documentation including this user manual are available for download from the MAC Aura XB Product Support page on the Martin website at www martin com Follow the safety precautions listed below and observe all warnings in this manual and printed on the product Keep this manual for future use PROTECTION FROM ELECTRIC SHOCK Do not expose the fixture to rain or moisture e Disconnect the fixture from AC power before carrying out any installation or service work and when the fixture is not in use e Ensure that the fixture is electrically connected to ground earth e Use only a source of
26. Da E Pe eee Ae a 14 B am Aura and FX CONWON lt n bane tis otis Bate he WSEAS Khe Sa Spa ee id ew eee eee 14 ANON PERO Mancera tract notte e oo ae a oso S awu s bees Oe A 15 Restoring factory default settings nnna aaa ew eevee leet eh ewe hee ee a 16 Operator and enel esiyor oa n satan squa ee a aus ku Pu pa Ree nd 17 Fil rakunta oes A gee ese 17 A nn E O ee ee es Bee Ge 19 Service and maintenance 20 CIS AMMA z Ssh hh Sa sere ee Rate at eG eae te ete ark ek eee aad Ae Ged mee ee pu t 20 Control menu Service utilitiesSs __ __ See Se daw ee eh nds 21 FIMO Sa OU crasas ess amp 2 ae awe ea sta aa agan ua Nar Suyos nda etd oe 22 LUDICA ION ui u tee das bt a ay Octet el ete a ios paca dsd ind 22 LIN DL OLOC PP x od eine eect oo ae ale Sa a ae eek Be ee eats cd ae 23 FX pre programmed effectSs 28 LEE colors and RGB CquIVGICINS sanieren ieia erreianvedsniotsauedens 29 OnBoard control Menus ose fers iis a crea epee arieves teu anos wgnbde 30 DISDIa TOSSA ri a e eos wie 32 TEOUDlESAOQUAO ari ii 33 a A A khusus puma ou sas 34 PowerCON TRUE1 installation instructions 37 6 MAC Aura XB user manual Fixture overview Control buttons x 0 35 o lt 0 5 5 s 9 Ec o lt AC mains power input DMX output DMX input Safety ca
27. Important Yellow O ring to hide to achieve IP protection 6 Tool available Art No HTAC CAUTION To ensure protection category do not expose the connection to bending forces e g do not attach loads to the cable no free dangling cable windings etc Disassembly open twist lock 1 Press with screw driver to unlock 2 Turn bushing while still pressing locking NEUTRIK AG LI T 423 237 24 24 F 423 232 53 93 NEUTRIK France FR T 33 1 4131 6750 F 33 1 4131 0511 NEUTRIK USA Inc USA T 1 704 972 3050 F 1 704 438 9202 NEUTRIK Tokyo Ltd JP T 81 3 3663 4733 F 81 3 3663 4796 NEUTRIK UK Ltd UK T 44 1983 811441 F 44 1983 811 439 NEUTRIK Hong Kong Ltd HK T 852 2687 6055 F 852 2687 6052 NEUTRIK Vertriebs GmbH DE NL AT DK T 498131 280890 F 498131 280 830 NEUTRIK India Pvt Ltd IND T 91 982 05 43 424 F 91 22 26163 540 Draft Nr BDA 380 Update 08 04 2014 Data subject to change without prior notice 2014 NEUTRIK ALL RIGHTS RESERVED NEUTRIK are registered trademark www neutrik com PA E J E re NK r Mart n by HARMAN www martin com e Olof Palmes All 18 8200 Aarhus N e Denmark Tel 45 8740 0000 e Fax 45 8740 0010
28. LET OUTLET COMBINATION NAC3FPX NAC3PX NAC3FPX ST Fal gt NAC3FX W j AH Connector lt lt lt E NAC3MX W NAC3MX W gt NAC3FX W Connector Plug connector Plug connector Approval based VDE UL EN 60320 1 EN60320 2 2 A UL 498 CSA C22 2 No 182 3 Y Rating 250Vac 16A 250 V ac 20 A Cable Type H05VV F3G 1 0 mm Length max 2 m SJTOW SJOOW 3 x 12 AWG HO5VV F3G 1 5 2 5 mm HO7RN F3G 1 5 mm Strain Relief White chuck White chuck Cable O D 6 0 12 0 mm 6 0 12 0 mm B ASSEMBLY INSTRUCTION A Insert cable into the Separate the bushing and housing housing from the Note Apply cable bushing cable pulling lubricant to remain in bushing cable jacket Place chuck over the cable 20 mm 0 787 a 0 32 D Prepare cable as shown PE 23 mm 0 97 PE 23 mm 0 9 VDE EN 60320 1 EN60320 2 2 UL UL 498 CSA C22 2 No 182 3 BDA 380 Page 1 ASSEMBLY INSTRUCTION powerCON TRUE1 the screw with Torx size T8 Wiring VDE UL Slide the cable into the contacts and clamp with Torx size T8 L gt HE brown E black N gt E blue white gt ff green yellow MM green Slide chuck onto insert 1 and then both into housing 2 Important Align the chuck by positioning the nose into keyway PRESS FIRMLY gt 6 gt Wrench size 13 mm Slide the cable clamp bushing up the cable and tighten it with the tool as shown
29. X Protocol Note DMX values labeled No function will have no effect the last functional value will be used If COLOR CALIB is set to OFF in the control menus RGBW RGB and color wheel effect output is uncalibrated If COLOR CALIB is set to ON output is calibrated DMX protocol 27 FX pre programmed effects The table below lists the pre programmed effects that can be selected on DMX channels 15 and 17 Two effects can be superimposed by selecting one effect on channel 15 and a different effect on channel 17 28 DMX Type value Percent FX Name FX Adjust Dimmer sync Idle n a Dimmer sync n a Strobe sync n a Aura Sync Dimmer strobe sync n a Aura color sync n a Aura all sync n a Reserved n a Aura strobe delay Aura strobe delay Trigger Delay Strobe alternate single Speed Strobe alternate dual Speed Strobe alternate triple Speed 3 step strobe Speed Intensity FX Reserved n a Intensity random alternate Speed Aura ramp Beam flash Speed Beam ramp Aura flash Speed Intensity Aura Beam ramp Speed Intensity Beam Aura ramp Speed Reserved n a Aura color offset 100 102 Aura color offset Color offset 103 108 Reserved n a 109 111 Hue shimmer Amount 112 114 Saturation shimmer Amount 115 126 Reserved n a SOET 127 129 Color strobe n a 130 132 Color offset strobe Color offset on strobe 133 135 Aura color strobe n a 136 138 Aura color offset strobe Aura color offset on strobe 139 141 Color spikes Strength 142 15
30. am the LEDs that provide the main output and e The Aura the secondary LEDs that illuminate the front of the head provide local diffuse light output and can be set to contrast with the Beam output See Beam Aura and FX control on page 14 for full details of these modes and how to set them up Shutter effect The electronic shutter effect available for the Beam and the Aura provides instant open and blackout variable speed regular and random strobe and opening closing pulse effects as well as burst and sine wave effects Dimming Beam and Aura intensity can be adjusted 0 100 using electronic dimming See the available dimming curve options in Dimming on page 16 Zoom The Beam can be zoomed from 53 to 11 one tenth peak angles Aura output is automatically dimmed as the zoom approaches maximum There is a linear dimming curve from normal Aura output when the Beam is at 90 zoom to zero Aura output when the Beam is at maximum narrow zoom Pan and tilt The MAC Aura XB s moving head can be panned through 540 and tilted through 232 The speed of pan tilt movement can be adjusted on the DMX fixture control channel 8 and in the fixture s onboard control panel Both EXT and STD control modes offer fine control of pan and tilt In each case the main control channel sets the first 8 bits the most significant byte or MSB and the fine channel sets the second 8 bits the least significant byte or LSB of the 1
31. ands reverse the direction of pan and tilt and the SWAP command sends pan commands to tilt and vice versa These settings are useful for symmetrical effects with multiple fixtures Cooling FANS gives you a choice of two settings e The default setting REGULATED should suit use in all normal situations and ensure excellent service lifetimes for all components e FULL maximizes cooling and reduces the operating temperature of the components in the head It is recommended when the MAC Aura XB is used intensively in a warm environment or in fixed installations Note that it will give increased fan noise compared to the other cooling modes Whatever cooling mode is selected a thermal cutout shuts down power to the LEDs if the fixture temperature exceeds safe limits If this occurs you must reset the fixture via the control menus or via DMX or cycle power to the fixture off and on again If a thermal shutdown occurs you are pushing the fixture to its limits Clean the fixture particularly the air vents and check that there is sufficient airflow around the fixture Consider increasing ventilation reducing the ambient temperature or switching to FULL mode Contact Martin for service if a thermal shutdown persists Setup 15 Dimming DIMMER CURVE provides four dimming options see Figure 4 Output Output DMX DMX Optically linear Square law Inverse square law S curve Figure 4 Dimming curve options LINEAR th
32. ble attachment point Figure 1 Fixture overview Fixture overview Introduction Thank you for selecting the MAC Aura XB an intelligent lighting fixture from Martin Professional This compact LED based moving head washlight features e Support for HD and high speed video camera technology e Independent or linked Beam primary LED array and Aura secondary background LED array control e Range of pre programmed independent and synchronized Beam and Aura effects available via DMX that give instant access to the full potential of the fixture e Beam RGBW color control with color temperature control e Aura RGB control e Color wheel color snap Beam and Aura effects e Onboard control panel and backlit LCD graphic display Motorized zoom e Smooth electronic dimming Electronic shutter with strobe and pulse effects e Calibrated and raw modes e DMX control and RDM fixture management e 540 pan and 232 tilt ranges For the latest firmware updates documentation and other information about this and all Martin Professional products please visit the Martin website at http www martin com Comments or suggestions regarding this document may be e mailed to service martin dk or posted to Technical Documentation Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Using for the first time Important The MAC Aura XB must be protected from environmental factors such as physical shocks and vibration durin
33. but the exact hues of more saturated color may be less evenly matched across MAC Aura XB fixtures than in RGB mode The white spot is calibrated across fixtures COLOR MODE RAW allows all LEDs to be operated to the maximum output level of the standard MAC Aura so that MAC Aura XB and standard MAC Aura fixtures can be controlled together As RAW mode is uncalibrated color and white output can vary slightly between fixtures In RAW mode the Beam has color wheel effect and RGBW options available In RGBW control the Beam s white LED control channel must be adjusted to control white output FX pre programmed Beam and Aura effects A library of pre programmed effects in which Beam and Aura output can be independent or synchronized is available via DMX These effects are simply called FX in this manual and in the fixture menus The library is available twice in the DMX channel layout with identical functions and effects and two different FX can be combined and run simultaneously with one superimposed over the other See FX pre programmed effects on page 28 for an overview of the FX available The MAC Aura XB Product Support page on www martin com features a downloadable detailed description of the parameters adjusted and algorithms applied in the different FX Effects are selected using the FX select DMX channels 15 and 17 Where modification is possible the selected FX can be modified using its FX adjust channel Modifications
34. can include speed amount offset smoothness etc depending on the FX selected FX Sync and Random operation The FX system uses a dedicated internal synchronization clock If two different FX that repeat in cycles are activated the FX Sync DMX channel 19 can be used to synchronize them When two FX are synchronized the repeat cycle of FX2 is adjusted to ensure that FX2 arrives at the end of a cycle and starts to repeat the cycle at the same time as FX1 If one FX with a short repeat cycle is combined with another FX with a long repeat cycle the short FX can repeat twice or more in the time it takes the long FX to repeat once But if two FX with different repeat cycles are synchronized the short cycle is adjusted so that it arrives at the end of a cycle at the same time as the long cycle MAC Aura XB user manual RDM Sync shift The sync shift option modifies FX synchronization so that FX2 runs with a time offset This means that the FX2 cycle start point is delayed relative to FX1 but the amount of the delay remains constant Random operation Selecting random operation makes random changes in the duration of those FX effects that have repeat cycles This means that some cycles are shorter and some cycles are longer in a random pattern The random sync option changes the duration of FX repeat cycles in a random pattern Cycle duration is random but it is always changed by the same amount for FX1 and FX2 so that FX remain synchronize
35. ce must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview on page 7 if the fixture is to be installed in any location where it may fall and cause injury or damage if the primary attachment fails Mounting the fixture on a truss 12 The MAC Aura XB can be clamped to a truss or similar rigging structure in any orientation Warning Use a rigging clamp with an M12 bolt if suspending the fixture from its base The clamp must be screwed into the central threaded hole in the fixture base The M12 bolt must protrude 20 30 mm 0 8 1 2 ins into the fixture base An M12 bolt that is suitable for many types of rigging clamp is supplied with the MAC Aura XB but you must pass the bolt through the clamp and check that the distance the bolt will protrude into the fixture base is within the 20 30 mm limits before using it If the bolt is not within these limits you must find an alternative bolt that is MAC Aura XB user manual To clamp a MAC Aura XB to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Obtain a rigging clamp such as the G clamp Half coupler clamp or Quick trigger clamp available as
36. d The overall speed of this synchronized effect is controlled on channel 16 The random no sync option changes the duration of FX effect cycles in a random pattern and FX1 and FX2 are not synchronized The speed of FX1 and FX2 effects are controlled independently on channels 16 and 18 respectively FX priority and overriding If an FX is activated it overrides any other settings for the parameters that the FX modifies For example an FX that modifies the zoom will override any zoom angle set on the zoom channel DMX channel 3 If the same FX is selected on both the FX1 select and FX2 select channels only the FX1 adjust channel is active The FX2 adjust channel is ignored If different FX are selected on the FX1 select and FX2 select channels FX2 is superimposed onto FX1 and FX2 overrides FX1 whenever both FX modify the same parameter RDM Remote Device Management is implemented in the MAC Aura XB and RDM communication is possible over the DMX data link As provided for in the ANSI ESTA E1 20 RDM protocol the fixture can send information about its RDM accessible parameters to an RDM control device Operation and effects 19 Service and maintenance Warning Read Safety Information on page 3 before servicing the MAC Aura XB Warning Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling Do not view the light output from less than 8 3 meters 27 ft 3 inches without shade 4 5 we
37. e increase in light intensity appears to be linear as DMX value is increased SQUARE LAW light intensity control is finer at low levels and coarser at high levels INVERSE SQUARE LAW light intensity control is coarser at low levels and finer at high levels S CURVE light intensity control is finer at low levels and high levels and coarser at medium levels Whichever DIMMER CURVE option you select you can choose between FAST or SMOOTH dimming settings e FAST is the default setting It gives a virtually instantaneous reaction when you dim from one intensity to another but dimming slowly from one intensity to another may appear slightly uneven The SMOOTH setting gives smoother dimming during slow changes in intensity but it limits the speed of dimming changes slightly This makes it ideal for slow smooth dimming but a short time lag may be noticeable if you try to dim quickly from one intensity to another Restoring factory default settings 16 The MAC Aura XB factory default settings can be restored by applying a FACTORY DEFAULT gt LOAD command MAC Aura XB user manual Operation and effects Effects Warning Read Safety Information starting on page 3 before installing powering operating or servicing the MAC Aura XB See DMX protocol on page 23 for a full list of the DMX channels and values required to control the different effects Beam and Aura The MAC Aura XB has two LED arrays The Be
38. etting and addressing Control panel with backlit graphic display DINA COMPDUANCC caia rasta si ia dai eae USITT DMX512 A FDNM G HIDIa 66 uy ars amp sd ra ad ander ANSI ESTA E1 20 RDM HallSeeyer isi wade A a aii ado ira RS 485 Firmware update Via DMX with Martin USB Duo DMX Interface Construction CO OF amics sais tios oa pea Bereta Q stala taa i sie Black PIOUSING cora ra High impact thermoplastic flame retardant to UL 94 5VA POlECIIONIAUING 24 nat A he ae PA A A A AE ASIA A ROA IP 20 Installation Mounting points M12 hole for rigging clamp attachment points for surface mounting bracket io O O ON O Any Minimum distance to combustible materials ooooo 200 mm 8 in from fixture Minimum distance to illuminated surfaces 1 m 3 ft 4 in from fixture OC AU Or crcac Coto neal vee tee nan cee ee ee ee Indoor use only must be fastened to structure or surface MAC Aura XB user manual Connections AG DONG rx y 2 pe reueeungteee gee uqg a S u ese DS Neutrik PowerCON TRUE1 NAC3PX dual socket AC power IN socket accepts Neutrik PowerCON TRUE1 NAC3FX W cable connector AC power OUT THRU socket accepts Neutrik PowerCON TRUE1 NAC3MX W cable connector DMX data INOUE 39m portar PEAR eee eke eee ee a 5 pin locking XLR Electrical AC POWE 22 bsos sois s PP ee 100 240 V nominal 50 60 Hz Maximum power consumption n
39. ettings read out data and execute service utilities See Onboard control menus on page 30 for a complete list of menus and commands Some of the commands available in the control panel are also available on the fly via DMX on channel 8 the fixture control channel See channel 8 under DMX protocol on page 23 for a list of the commands available Using the control buttons e To enter a menu select a function or apply a selection press gt Enter e Press MA Up and Y Down to scroll within a menu or adjust values To escape a function or move back one level in the menu structure press 4 Menu Escape Control button reset shortcut e Holding 4 Menu Escape pressed in and pressing 4 Up forces the fixture to reset Display panel functions The DMX address is shown in the display panel when the MAC Aura XB is powered on and has reset The display panel backlighting indicates fixture status as follows e The display blacks out during resets e The display flashes slowly if the fixture is not receiving a valid DMX signal unless the control buttons are used In this case the display behaves normally until the buttons have not been used for a short period then begins to flash slowly again e The display can be set to go into sleep mode via PERSONALITY gt DISPLAY in the control menu Connecting a DMX signal wakes up the display DMX address setting The DMX address also known as the start channel is the
40. ev C Safety Information WARNING Read the safety precautions in this section before installing powering operating or servicing this product The following symbols are used to identify important safety information on the product and in this manual AAAAAA WARNING WARNING WARNING WARNING WARNING WARNING Refer Safety hazard Hazardous Fire hazard Burn hazard Hot Powerful light to user manual Risk of severe voltage Risk of surface Do not emission Risk of for important injury or death lethal or severe touch eye injury Safety electric shock information Warning Risk Group 2 LED product according to EN 62471 Do not view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only it is not for household use The fixture must be installed by a qualified technician The safety of the installation is the responsibility of the installer The fixture presents risks of severe injury or death due to fire hazards electric shock and falls It produces a powerful concentrated beam of light that can create a fire hazard or a risk of eye injury if the safety precautions below are not followed If you have any questions about how to install operate or service the fixture safely please contact your Martin distributor see www martin com distributors for details or call the Martin 24 hour service hotline on 45 8740 0000 or in the US
41. g transportation and storage to a level of protection equal to that provided by Martin brand flightcases Warning Read Safety Information on page 3 before installing powering operating or servicing the MAC Aura XB Before applying power to the fixture e Check the Martin Professional website at www martin com for the most recent user documentation and technical information about the MAC Aura XB Martin user manual revisions are identified by the revision letter at the bottom of page 2 Carefully review Safety Information starting on page 3 e Check that the local AC mains power source is within the fixture s power voltage and frequency ranges e See Power cables and power plug on page 9 Install a Neutrik PowerCON NAC3FX W power input connector on a suitable power input cable cable and connector must be ordered separately If drawing power from a mains power outlet install a suitable power plug on the power input cable 8 MAC Aura XB user manual AC power Warning Read Safety Information starting on page 3 before connecting the MAC Aura XB to AC mains power Warning Before you connect any device to the MAINS OUT socket see Linking fixtures to power in a chain on page 10 Warning For protection from electric shock the MAC Aura XB must be grounded earthed The power distribution circuit must be equipped with a fuse or circuit breaker and ground fault earth fault protection Warning Socket ou
42. hat lubrication may be required This operation can be carried out by a Martin service partner if necessary MAC Aura XB user manual DMX protocol Channel DMX Fade Default Std Ext value Percent Function status value Beam electronic shutter effect 0 19 0 7 Shutter closed 20 24 8 9 Shutter open 25 64 10 25 Strobe 1 fast slow 65 69 26 27 Shutter open 70 84 28 33 Strobe 2 opening pulse fast slow 85 89 34 35 Shutter open 90 104 36 41 Strobe 3 closing pulse fast slow 105 109 42 43 Shutter open 110 124 44 49 Strobe 4 random strobe fast slow 125 129 50 51 Shutter open 1 130 144 52 57 Strobe 5 random opening pulse fast slow Snap 22 145 149 58 59 Shutter open 150 164 60 65 Strobe 6 random closing pulse fast slow 165 169 66 67 Shutter open 170 184 68 73 Strobe 7 burst pulse fast slow 185 189 74 75 Shutter open 190 204 76 81 Strobe 8 random burst pulse fast slow 205 209 82 83 Shutter open 210 224 84 89 Strobe 9 sine wave fast slow 225 229 90 91 Shutter open 230 244 92 97 Strobe 10 burst fast slow 245 255 98 100 Shutter open Beam dimmer 2 0 255 0 100 0 gt 100 intensity Pade o Zoom 3 0 255 0 100 Wide narrow page ll 272 Pan 4 O 255 0 100 Pan 0 540 pace ue Pan fine 9 0 255 0 100 Pan fine adjustment Least Significant Byte Rage ee Tilt 6 0 255 0 100 Til 0
43. isted pair cable designed for RS 485 devices standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs e Never use both a fixture s outputs to split a DMX link To split the link into branches use a splitter such as the Martin 4 Channel Opto Isolated RS 485 Splitter Amplifier Terminate the link by installing a termination plug in the output socket of the last fixture The termination plug which is a male XLR plug with a 120 Ohm 0 25 Watt resistor soldered between pins 2 and 3 soaks up the control signal so it does not reflect and cause interference If a splitter is used terminate each branch of the link Connecting the data link To connect the MAC Aura XB to data 1 Connect the DMX data output from the controller to the closest MAC Aura XB s male 5 pin XLR DMX input connector 2 Connect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and continue connecting fixtures output to input 3 Terminate the last fixture on the link with a 120 Ohm resistor Data link 11 Physical Installation Warning The MAC Aura XB must be either fastened to a flat surface such as a stage or wall or clamped to a truss or similar structure in any orientation using a rigging clamp Do not apply power to the MAC Aura XB if it is standing freely or
44. lding goggles Be prepared for the fixture to light suddenly if connected to power Warning Refer any service operation not described in this user manual to a qualified service technician Important Excessive dust smoke fluid and particle buildup degrades performance causes overheating and will damage the fixture Damage caused by inadequate cleaning or maintenance is not covered by the product warranty The user will need to clean the MAC Aura XB periodically and it is also possible for the user to update the fixture s software All other service operations on the MAC Aura XB must be carried out by Martin Professional or its approved service agents Installation on site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents giving owners access to Martin s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your Martin supplier for details It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lifetimes However LEDs are subject to wear and tear over the life of the product resulting in gradual changes in color and overall brightness over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions a
45. mber Flame Red Red 255 214 255 255 255 226 040 000 000 000 000 149 137 213 219 205 115 006 000 029 032 075 080 108 145 210 225 023 247 255 255 255 255 DMX Integer Green 235 134 000 059 138 175 001 000 078 199 255 246 255 220 232 255 255 255 255 255 223 255 232 226 194 255 232 215 214 163 152 108 080 LEE colors and RGB equivalents Blue 052 048 044 113 219 226 255 255 255 255 234 255 227 222 175 199 165 143 94 000 000 000 000 000 000 000 000 000 000 000 000 000 000 29 Onboard control menus Menu Item Options Notes Default settings in bold print DMX address default address 1 XXX means that the DMX address range is limited so that the fixture will DMA ADDRESS ES always have enough DMX channels within the 512 available Linked control of Beam and Aura using Beam channels STD Aura copies Beam Nope fixture uses 14 DMX channels EXT Independent control of Beam and Aura FX available fixture uses 25 DMX channels Color calibration mode on Independent white control not RGB available for Beam white controlled automatically by RGB dimming COLOR MODE EXTENDED Calibrated white point Extended color saturation RAW Raw RGBW dimming output limited to match standard MAC Aura in raw mode P T SPEED Pan and tilt speed normal fast slow SWAP Swap pan and
46. nd environment so it is impossible to specify precisely whether and to what extent LED performance will be affected However you may eventually need to ask Martin Professional to replace LEDs if their characteristics are affected by wear and tear after an extended period of use and if you require fixtures to perform within very precise optical and color parameters The manufacturer s LED lifetime data is based on performance under the manufacturer s test conditions As with all LEDs the gradual reduction in luminous output will be accelerated when LEDs are used in a fixture where conditions are much tougher than in manufacturer s testing To maximize LED lifetimes keep the ambient temperature as low as possible and drive the LEDs no harder and for no longer than necessary Cleaning Cleaning schedules for lighting fixtures vary greatly depending on the operating environment It is therefore impossible to specify precise cleaning intervals for the MAC Aura XB Environmental factors that may result in a need for frequent cleaning include e Use of smoke or fog machines e High airflow rates near air conditioning vents for example e Presence of cigarette smoke e Airborne dust from stage effects building structures and fittings or the natural environment at outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary Check again a
47. ng Yellow 140 144 54 55 LEE 104 Deep Amber 145 149 56 57 LEE 179 Chrome Orange 150 154 58 59 LEE 105 Orange 155 159 60 61 LEE 021 Gold Amber 160 164 62 63 LEE 778 Millennium Gold 165 169 64 65 LEE 135 Deep Golden Amber 170 174 66 67 LEE 164 Flame Red 175 179 68 69 Open Color wheel rotation effect 180 201 70 78 Clockwise fast gt slow 202 207 79 80 Stop this will stop wherever the color is at the time 208 229 81 89 Counter clockwise slow fast 230 234 90 91 Open Random color 235 239 92 93 Fast 240 244 94 95 Medium 245 249 96 97 Slow 250 255 98 100 Open Beam red 10 0 255 0 100 Red0 100 page aay Beam green 11 0 255 0 100 Green 0 100 pager Beam blue 12 0 255 0 100 Blue 0 gt 100 rage Beam white 13 0 255 0 100 White 0 gt 100 Fade 0 Only available when the fixture is set to RAW mode Beam CTC Color Temperature Control 14 0 19 0 7 CTC disabled Fade 0 20 255 8 100 CTC 10 000K 2 500K FX1 select 15 0 255 0 100 Pre programmed effect 1 selection Snap 0 see FX pre programmed effects on page 28 FX1 adjust sync speed adjust O 255 O 100 Zero gt maximum 16 e If no sync set on channel 19 adjusts FX1 Fade 128 e If sync set on channel 19 adjusts synchronized FX1 FX2 speed FX2 select 17 O 255 0 100 Pre programmed effect 2 selection Snap 0 see FX pre programmed effects on page 28
48. o ensure that it cannot collide with an object or another fixture when it moves Contents DIMENSION Siro aia alee ed 2 Safety Information 3 F IXIHUIGOVeI VI SW gt arsraricaca did road ii ugut a ina ad 7 lil OG I uc uay tare atte ke a ter eee eater Sa gana a as ha SS S aus usqo tears ree tee eee 8 USING TO TMeMscUme iia a busua utu asa ee U ea en ema a a ae uw iba 8 AN L a Sua pred as et et a gre ees a ai a eed eee ede eine fade 9 POWCE VORAJ yI ach ach nase yt ss ka masi E uui teed ee Beek 9 Power Cables did power DIUG ester cir og we ee ee oe SDK Se ee eae A west a a 9 Linking fixtures to power inachain 00 eee ee eee ees 10 Dalla MINN u ua puas mentors III 11 Tips for reliable data transmission 11 Connecting the datalink sonrai at ak Gale ell a e it ga Pa gee teats teehee eA ait cial 11 PNYSIGALINSTANAUON 3 u orcctaae dey ok x cdithan te cea Oe Se yau e O E Debate aurea aie ates 12 Fastening the fixture to a flat Surface 1 u cette wQ ua aa 12 Mounting the TixtUre On a USS sido aos eee AS Sal eee Pee OE id 12 SUSPENAIN E MSM e eee ate St kao tine Sole E Z tate a waa E z e ahd wis hg ota 13 Quick mount surface mounting bracket 13 A 14 Control panel and menu Navigati0N o oo o o ooooooo eee eee 14 DMX address Selg car s ie SA eee A oe ieee
49. om Martin see Accessories on page 35 Using 14 AWG 1 5 mm power input and relay cables from Martin you can link e Maximum three 3 MAC Aura XB fixtures in total at 100 120 V or e Maximum eight 8 MAC Aura XB fixtures in total at 200 240 V MAC Aura XB user manual Data link A DMX 512 data link is required in order to control a MAC Aura XB via DMX The MAC Aura XB has 5 pin XLR connectors for DMX data input and output The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Pins 4 and 5 in the 5 pin XLR connectors are not used in the MAC Aura XB but are available for possible additional data signals as required by the DMX512 A standard Standard pin out is pin 4 data 2 cold and pin 5 data 2 hot The MAC Aura XB is not subject to the limit of 32 devices per daisy chained link which is common in Martin fixtures Instead the number of fixtures is either limited to 256 or limited by the number of DMX channels required by the fixtures in relation to the maximum 512 channels available in one DMX universe whichever limit is lower Note that if independent control of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX channels To add more fixtures or groups of fixtures when the above limit is reached add a DMX universe and another daisy chained link Tips for reliable data transmission e Use shielded tw
50. on to warm it up Contact Martin service if problem continues or fixture is warm FAN ERROR there is a fan or fan driver error Check that fan on rear of head is free to rotate freely Contact Martin service for assistance COLOR ERROR there is a driver error Contact Martin service for assistance BEAM CALIB ERR RDM message Color Calibration Error 1 AURA CALIB ERR RDM message Color Calibration Error 2 color calibration data for Beam or Aura LEDs is invalid or there is a communication error Contact Martin service for assistance 32 Table 5 Display messages MAC Aura XB user manual Troubleshooting Problem Probable cause s Remedy Fixture is completely dead One or more fixtures resets correctly but responds erratically or not at all to the controller Light output shuts down unexpectedly No power to fixture Internal circuit fault Fault on data link Data link not terminated Incorrect fixture DMX addressing One of the fixtures is defective and is disturbing data transmission on the link XLR pin out on fixtures does not match pins 2 and 3 reversed Fixture is too hot Table 6 Troubleshooting Troubleshooting Check AC mains power and connections Have faulty fixture serviced by Martin service technician Inspect connections and cables Correct poor connections Repair or replace damaged cables Insert termination
51. pening pulse fast slow 85 89 34 35 Shutter open 90 104 36 41 Strobe 3 closing pulse fast slow 105 109 42 43 Shutter open 110 124 44 49 Strobe 4 random strobe fast slow 125 129 50 51 Shutter open 20 130 144 52 57 Strobe 5 random opening pulse fast slow Snap 22 145 149 58 59 Shutter open 150 164 60 65 Strobe 6 random closing pulse fast slow 165 169 66 67 Shutter open 170 184 68 73 Strobe 7 burst pulse fast slow 185 189 74 75 Shutter open 190 204 76 81 Strobe 8 random burst pulse fast slow 205 209 82 83 Shutter open 210 224 84 89 Strobe 9 sine wave fast slow 225 229 90 91 Shutter open 230 244 92 97 Strobe 10 burst fast slow 245 255 98 100 Shutter open Aura dimmer 21 O 255 0 100 0 100 intensity Face i 26 Table 2 MAC Aura XB DMX Protocol MAC Aura XB user manual Channel DMX Fade Default Std Ext value Percent Function status value Aura color wheel effect 0 9 0 1 Open RGB color mixing enabled 10 14 2 3 LEE 790 Moroccan pink 15 19 4 5 LEE 157 Pink 20 24 6 7 LEE 332 Special rose pink 25 29 8 9 LEE 328 Follies pink 30 34 10 11 LEE 345 Fuchsia pink 35 39 12 13 LEE 194 Surprise pink 40 44 14 15 LEE 181 Congo Blue 45 49 16 17 LEE 071 Tokyo Blue 50 54 18 19 LEE 120 Deep Blue 55 59 20 21 LEE 079 Just Blue 60 64 22 23 LEE 132
52. rol intensity CTC Color Temperature Control CTC is available for the Beam on the CTC channel 14 Setting this channel to DMX value 20 or above allows you to adjust the Beam s overall color temperature i e the color that has been set using the color wheel channel or the RGBW channels Note that the more saturated the color the less it will be affected by adjustments in color temperature The biggest CTC variation is available when displaying white Overall color temperature can be varied from 10 000 2500 K In calibrated mode CTC affects the available color spectrum and maximum output slightly To obtain the full color and output ranges disable CTC by setting the CTC channel to zero Calibrated and raw color output The color control modes are available in the COLOR MODE menu COLOR MODE RGB is a calibrated mode that gives the best matched color gamut across multiple MAC Aura XB fixtures To achieve this it limits very slightly the levels of saturation that are possible In RGB mode the Beam has color wheel and RGB options available In RGB control the Beam s white LED control channel has no effect White output is added to the Beam s calibrated RGB output automatically as required to increase intensity Setting all three colors to 100 intensity gives 100 intensity white with the white LEDs at their calibrated maximum e COLOR MODE EXTENDED is a calibrated mode that allows deeper saturation than in RGB mode
53. s s saasaa eaea a a o a o 0 400 W Power supply UNI U Ju hee eet ee sta aaa adem ad a os a Auto ranging electronic switch mode Power consumption all effects static zero light output lt 25 W Typical half cycle RMS inrush current 10 7 A Typical Power and Current TOON DO Alo eii isis dene oe as L 359 W 3 8 A PF 0 99 A TAZ ein oe oe eee cas ob E eee eee a Pee eee o PGs enq eu 355 W 3 2 A PF 0 99 AU 2d ie neue b ts 654 eels Ea T oe heehee ow eee de 350 W 1 8 A PF 0 97 ZION OO Zu pots Bees eras hs ia bass oe ass ee ee ee ee eee ek 349 W 1 7 A PF 0 95 PAO O02 2444 odie oe hte d ohee bu sss oes oboe bee es eee a 349 W 1 6 A PF 0 95 PF power factor Measurements made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal Cooling Forced air temperature regulated low noise user definable levels Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 5 C 41 F Total heat dissipation calculated 10 1230 BTU hr Approvals D Intertek EU SAO o ERa ae aoe a a a aaa EN 60598 2 17 EN 60598 1 EN 62471 WIG eres a da dd e EN 55103 1 EN 55103 2 EN 55015 EN 61547 A o he Suma eee bee eee ee
54. stall it permanently or a power plug that is suitable for the local power outlets can be installed on the power cable If you install a power plug on the power cable install a grounding type earthed plug with an integral cable grip that is rated 250 V 16 A minimum Follow the plug manufacturer s instructions Table 1 shows standard wire color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts about proper installation consult a qualified electrician Wire Color Wire Color Conductor Symbol Screw US EU models US models brown black live L yellow or brass blue white neutral N silver yellow green green ground earth D or green Table 1 Wire color coding and power connections AC power 9 Linking fixtures to power in a chain 10 You can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket but you must respect the following safety limits If you connect fixtures to power in a chain The power input cable must be 14 AWG 1 5 mm minimum lfa power plug is installed on the power input cable it must be grounding type earthed with integral cable grip and it must be rated minimum 250 V 16 A All power relay cables used must be 14 AWG 1 5 mm minimum Suitable 14 AWG 1 5 mm power input and power relay thru cables are available fr
55. t frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your Martin dealer about a suitable maintenance schedule Use gentle pressure only when cleaning and work in a clean well lit area Do not use any product that contains solvents or abrasives as these can cause surface damage 20 MAC Aura XB user manual Warning Disconnect from power and allow to cool before cleaning To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture and the air vents at the back and sides of the head and in the base with low pressure compressed air 3 Clean the LED lens array in the front of the head by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub the surface hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Control menu service utilities Functions test The TEST feature provides four test routines that can be executed without a controller allowing testing of pan tilt and zoom LEDs and display separately or together Pan and tilt calibration
56. tilt pan commands move tilt and vice P T SETTING versa off on PAN INVERT Pan inversion reverse direction pan control off on TILT INVERT Tilt inversion reverse direction tilt control off on REGULATED Cooling fan speed thermostatically regulated FANS l FULL Max cooling fan speed LINEAR Linear dimming curve DIMMER SQUARE TAW Square law dimming curve CURVE LAW Q Inverse square law dimming curve S CURVE S curve dimming curve DIMMER FAST Fast dimming with unrestricted speed SPEED SMOOTH Smooth dimming with restricted speed PERSONALITY OFF Disable reset via DMX PIS RESEN ON Enable reset via DMX ON Display is always on 2MIN Display switches off and goes into Sleep mode if the controls have not been pressed for 2 minutes DISPLAY SMIN Display switches off and goes into Sleep mode if the controls have not been pressed for 5 minutes 10MIN Display switches off and goes into Sleep mode if the controls have not been pressed for 10 minutes DISPLAY l l INTENSITY 10 100 Display intensity Default 100 Display errors at 100 intensity regardless of NORMAL DISPLAY INTENSITY setting and illuminate the ERROR MODE service light SILENT Silent error mode The error message does not appear in the display but the service lamp is illuminated FACTORY FACTORY Return all settings except calibrations to factory SETTING DEFAULT FOAD aerau NB can take up to 2 minutes to complete Table 4 Control menu 30 MAC Aura XB user manual
57. tlets or external power switches used to supply the MAC Aura XB with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not use an external dimming system to supply power to the MAC Aura XB as this may cause damage to the fixture that is not covered by the product warranty Power voltage Warning Check that the voltage range specified on the fixture s serial number label matches the local AC mains power voltage before applying power to the fixture The MAC Aura XB has an auto ranging power supply that accepts AC mains power at 100V 240V 50 60Hz Do not apply AC mains power at any other voltage or frequency to the fixture Power cables and power plug The MAC Aura XB requires a power input cable that must be ordered separately The power input cable must have a Neutrik PowerCON TRUE1 NAC3FX W cable connector for AC mains power input The cable must meet the requirements listed under Protection from electric shock on page 3 MartinTM can supply either suitable 3 m 9 8 ft power INPUT cables with PowerCON TRUE1 input connectors installed or PowerCON TRUE1 connectors without cables see Accessories on page 35 If you need to install a PowerCON TRUE1 connector on a power cable see the instructions from Neutrik that are reproduced at the end of this manual The MAC Aura XB can be hard wired to a building electrical installation if you want to in
58. upler clamp fastened to the truss chord or similar bar Do not use G clamps quick trigger clamps or any other type of clamp that does not completely encircle the supporting structure when fastened When suspending the fixture ensure that the supporting structure and all hardware used can hold at least 10 times the weight of all the devices they support If suspending from a rigging structure fasten the fixture to a rigging clamp with an M12 bolt screwed into the threaded hole in the center of the base of the fixture The bolt must protrude at least 20 30 mm 0 8 1 2 ins into the fixture If the fixture is suspended by any other method an M12 bolt must be tightened into this hole so that it protrudes at least 20 30 mm 0 8 1 2 ins into the fixture If the fixture is installed in a location where it may cause injury or damage if it falls install as described in this manual a secondary attachment such as a safety cable that is approved by an official body such as T V as a safety attachment for the weight that it secures The safety cable must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Check that all external covers and rigging hardware are securely fastened Block access below the work area and work from a stable platform whenever installing servicing or moving the fixture Allow enough clearance around the head t
59. vailable on channels 20 25 See DMX protocol on page 23 for details of the DMX commands available in the different modes Recommended Beam and Aura control method Operating the MAC Aura XB in EXT mode will give full access to the fixture s effects Depending on the type of console used and the intended precision of control we recommend that you consider creating console libraries for the Beam and Aura either separately or in combined multi part fixtures Your console s user documentation should give details of how it handles multi part fixtures Separating Beam and Aura in this way may also be useful for pixel mapping applications where only the Aura is controlled by a media server For each device a Beam and Aura fixture will need to be patched consecutively Suggested setup Beam Use channels 1 through 19 Beam provides control of all parameters for the main Beam and the FX section Aura Use channels 20 through 25 Aura provides intensity strobe and color control for the Aura array Certain FX require Aura intensity to be above 0 to be visible Please consult the FX documentation available on www martin com for more details Tailoring performance Pan and tilt movement The P T SPEED settings set the maximum speed of pan and tilt movement FAST optimizes for speed and SLOW optimizes for smoothness of movement NORMAL is a compromise between these two The default setting is FAST The PAN INVERT and TILT INVERT comm
60. werCON TRUE1 connectors are available from Martin see Accessories on page 35 If you use the correct cables and connectors as described above you can connect fixtures to AC power in a linked chain MAINS OUT throughput socket to MAINS IN input socket but do not link more than three 3 MAC Aura XB fixtures at 100 120 V 60 Hz or eight 8 MAC Aura XB fixtures at 200 240 V 50 Hz Do not connect devices to power in a chain that will exceed the electrical ratings of any cable or connector used in the chain Connect only other MAC Aura XB fixtures to the MAINS OUT power throughput socket Do not connect any other type of device to this socket The voltage and frequency at the MAINS OUT power throughput socket are the same as the voltage and frequency applied to the MAINS IN socket PROTECTION FROM BURNS AND FIRE Do not operate the fixture if the ambient temperature Ta exceeds 40 C 104 F The exterior of the fixture becomes hot during use After 5 minutes of operation a surface temperature of 67 C 153 F shall be expected and the maximum steady state is 70 C 158 F Avoid contact by persons and materials Allow the fixture to cool for at least 10 minutes before handling Keep all combustible materials e g fabric wood paper at least 200 mm 8 in away from the fixture Keep flammable materials e g volatile liquids pyrotechnics fuel of any kind well away from the fixture Ensure that there is free and