USER MANUAL CONDUCTIVITY & TDS METERS WITH CAL
Contents
1. SPECIFICATIONS MW Milwaukee RANGE SMS315 0 00 to 9 99 mS cm SMS415 0 to 1990 mg L ppm RESOLUTION SMS315 0 01 mS cm SMS415 10 mg L ppm 2 Full Scale approx 0 7 SMS415 only ACCURACY 25 C CONVERSION FACTOR TEMPERATURE Automatic COMPENSATION from 5 to 50 C with B 2 C ENVIRONMENT 0 to 50 C 95 RH max PROBE SMS315 MA815 2 included SMS415 MA816 2 included POWER SUPPLY external 12VDC power adapter included DIMENSIONS 85 x 104 x 39 mm WEIGHT 130 g meter only OPTIONAL ACCESSORIES M10031B 1413 uS cm calibration solution 20mL sachet 25 pcs M10442B 1500 ppm cal solution 20mL sachet 25 pcs M100020B Cal Test solution for SMS315 20mL sachet 25 pcs M100040B Cal Test solution for SMS415 20mL sachet 25 pcs MA815 2 MA816 2 Conductivity probe for SMS315 with 2m cable Conductivity probe for SMS415 with 2m cable To be replaced by technical personnel only WARRANTY These instruments are warranted from all defects in materials and manufac turing for a period of two years from the date of purchase The probes are warranted for a period of 6 months If during this period the repair or replacement of parts is required where the damage is not due to negligence or erroneous operation by the user please return the parts to either dealer or our office and the repair will be effected free of charge Note We reserve the right to modify the design construction and appearance of o
2. metal pins with fine sandpaper and then rinse with water e Open a sachet of suitable conductivity calibration solution and immerse the probe making sure the metal pins are completely submerged Use M10031 1413 uS cm for SMS315 and M10442 1500 ppm for SMS415 These calibration solutions are recommended for applica tions in agriculture and hydroponics e Wait until the reading stabilize for temperature variations and then adjust the CAL trimmer on the meter side with the supplied screwdriver until the display shows 1 41 mS cm for SMS315 and 1500 ppm for SMS415 e The calibration is now complete and the meter is ready to take measurements If calibration can not be reached the probe has to be replaced Contact your dealer for technical service
3. ur products without advance notice ZO LL LYSLETIWSI AY Milwaukee CONDUCTIVITY amp TDS METERS WITH CAL TEST MODELS SMS315 amp SMS415 Smart Monitoring System USER MANUAL amma Smart EC Monitoring System 500 Cal Test ox ca Z OPERATION e Connect the supplied 12VDC MY ViwauKes power adapter to the meter and to the mains line Immerse the tip 4 cm of the conductivity probe into the sample e Wait for thermal equilibrium to be reached and the meter will start continuous monitoring t 12VDC EC PROBE ADAPTER CALIBRATION TEST These meters are provided with a check system which allows to verify the calibration status in a fast and easy way It is recommended to perform the below operations once a month e Rinse thoroughly the probe with water e Immerse the probe in the suitable Cal Test solution M100020 for SMS315 M100040 for SMS415 e Wait for one minute and then push the Cal Test button on the meter front e lf the GREEN LED lights up the meter is calibrated e lf the RED LED lights up clean the probe immerse it in the Cal Test solution and push again the button If the GREEN LED lights up the meter does not need cali bration e If the red LED lights up cali brate the meter uN CALIBRATION PROCEDURE e Clean the probe with alcohol and let it dry if a more thor ough cleaning is required brush the
Download Pdf Manuals
Related Search
Related Contents
平成18年2月3日 各 位 株主優待詳細決定のお知らせ 記 株 UNA 23 UNA 25 UNA 26 UNA 27 平成 24 年度 農業用水小水力発電設備設置 実証試験委託 DTC 100/2 - Technocosmos.Gr Nikon Coolpix S700 12.1mp Digital Camera With 3x Optical Zoom With Vibration Reduction Silver Copyright © All rights reserved.
Failed to retrieve file