Home

User Manual

image

Contents

1. Biohazard after use yal Manufacturer Warning CE European Conformity gt gt eee Type B applied part European Authorized Rep ad BING INNOVATIONS LLC 990 South Rogers Circle Suite 4 Boca Raton FL 33487 877 503 VIBE 8423 www DentalVibe com info dentalvibe com CE European Authorized Representative AR EC REP 2015 Bing Innovations LLC All rights reserved Under the copyright laws this manual may not be copied in whole or in part without the express written consent of Bing Innovations LLC Every effort has been made to ensure that the information in this manual is accurate Bing Innovations LLC is not responsible for printing or clerical errors This product may be covered by one or more US patents or pending patent applications See www DentalVibe com patents for details FDA Registered Reverse engineering or disassembly is prohibited Model Name DentalVibe GEN 4 Model VIBE4 Manufactured in the USA REV 3 2015 04 22
2. an authorized Bing Innovations LLC Service Center closest to you INTENDED USE DentalVibe is a vibrating retractor and is intended for use by dental professionals in a dental office setting It has been carefully designed to offer your patients a more comfortable dental injection experience that is both safe and effective It does not modify the tissue or impart energy and is not intended for therapeutic diagnostic or any other purpose The use of the DentalVibe varies between 10 120 seconds per application Contraindication for use Do not use in an area where an abcess is present WARNING Read all instructions before use 1 Do not place or store the charger where it can fall or be pulled into a sink 2 Do not place the hand held unit or charger in water or other liquid 3 Do not reach for a charger that has fallen into water Unplug immediately 4 Use this type B applied product only for its intended use as described in the manual Do not use attachments or chargers not recommended by the manufacturer Position the charger so the power supply is easy to unplug j Never insert any objects into any opening of the unit or charger base 7 Never operate the product ifit has a damaged cord or plug not working properly has been dropped damaged or submerged into water If any of these occur contact a service center and return the product for examination and repair IMPORTANT 8 Periodically check the cord for da
3. DENTAMW BE INJECTION COMFORT SYSTEM Get to know your DentalVibe GEN 4 Learn the correct pressure that stimulates the sensory receptors by experiencing the DentalVibe on yourself first 1 Place a new comfort tip on to a fully charged DentalVibe and turn it on 2 Rest the vibrating tip above your upper lip Apply differing pressure to the skin and you will notice that a light touch delivers the greatest amount of stimulation Charging DentalVibe is equipped with a Nickel Metal Hydride NiMH rechargeable battery Only use provided power supply I iteztysesinosa iat 1O 1 Insert power supply cord into recepticle on charger base plug power supply into an electrical outlet Use international plug adaptors as needed 2 Charge the DentalVibe at least 15 hours before initial use 3 After each patient use place the DentalVibe back in it s charging base Note Battery does not experience the memory effect DENTALVIBE LED INDICATOR LIGHT BLINKS AMBER off charger while button is pressed needs anew tip BLINKS AMBER on charger battery is charging BLINKS AMBER off charger battery needs to be charged BLINKS GREEN on charger when ready for use Note DentalVibe needs to be placed on charger until light blinks green 3 Comfort Tip Note Comfort Tips are Latex Free Installing the Comfort Tip for use 1 Remove a fresh Comfort Tip from its sealed bag in plain vie
4. ervice Center is the responsibility of the dental practice the cost to return the product to the dental practice is the responsibility of Bing Innovations Warranty does not cover finishes or normal wear nor does it cover damage resulting from accident misuse dirt water tampering unreasonable use use of any tip other than those supplied by Bing Innovations LLC or covering the tip with a plastic sleeve service performed or attempted by unauthorized service agencies failure to provide reasonable and necessary maintenance including recharging or units that have been modified or used for commercial purposes ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF ORIGINAL PURCHASE IN NO EVENT WILL BING INNOVATIONS LLC BE RESPONSIBLE FOR CONSEOUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other legal rights which vary from state to state 10 OBTAINING Should this product require service please call 1 877 503 VIBE 8423 to be referred to the authorized Bing Innovations LLC Service Center closest to you EXPLANATION OF SYMBOLS Consult User Manual Electrical Hazard Do Not Re Use LJ Double insulated
5. mage If cord is damaged ship the charging unit to a Bing Innovations Service Center A damaged or non functioning unit should no longer be used 9 Do not touch the power cord with wet hands as this can cause electric shock 10 When unplugging always hold the power plug instead of the cord 11 Do not put metal objects such as coins or clips on the charger This may generate heat damaging the unit and heating the metal item presenting potential burn hazards 12 No User Serviceable Parts Do not modify this equipment without authorization of the manufacturer if equipment is modified appropriate inspection and testing must be conducted to ensure continued safe use 13 Batteries are not user serviceable 14 Equipment protected from AC power by double insulation or reinforced insulation by use of the supplied power supply Wil not cause electromagnetic interference and complies with 601 1 2 A o A A G Limited 1 year warranty Bing Innovations LLC warrants this appliance to be free of defects in material and workmanship for a period of one year from the date of original purchase If appliance exhibits such a defect Bing Innovations LLC will at its option repair or replace it without cost for parts and labor The product must be shipped prepaid and insured recommended to an authorized Bing Innovations LLC Service Center Proof of date of original purchase is required The cost to ship the product to an authorized S
6. tly touching the back of their hand or on the outside of their cheek before placing in the mouth 3 Position DentalVibe s Comfort Tip on the oral mucosa at the injection site 4 Vibrate 10 seconds before inserting the needle 5 Maintain contact and vibrate the tissue during the entire injection plus 2 seconds after the injection 6 Insert the needle as close as possible to one of the vibrating prongs For instructional videos visit http www dentalvibe com instructional videos gme e MW mi gt Caring for your DentalVibe SUPPLIED PARTS DentalVibe hand piece Charging base with Power Supply and Comfort Tips CLEANING INSTRUCTIONS Wipe handle clean with plastic safe surface disinfectant Thoroughly wet the handle and ensure that the surface remains visibly wet for 1 minute at room temperature 68 F 20 C Do Not place DentalVibe or Comfort Tip in an autoclave Do Not immerse DentalVibe or Charger in water Remove the power cord plug from the electrical outlet before cleaning the charger Permissible environmental conditions during normal use Temperature Hum Barometre pressure Operating 18 C to 30 C 30 85 RH 100kpa 50kpa Storage 20 Cto 45 C 10 85 RH 100kpa 50kpa A DO NOT OPEN THE DENTALVIBE OR CHARGING BASE The internal circuit boards are manufactured in a static free environment For service or battery replacement please call 1 877 503 VIBE 8423 for
7. w of your patient Align the arrow on the Comfort Tip with the arrow on the DentalVibe unit Push straight down until it snaps on securely see photos 2 Each Comfort tip is programmed to be turned on and off a total of 6 times and will run for a total of 6 minutes Removing the Comfort Tip after use 1 While holding the DentalVibe unit in one hand grasp the clear plastic portion of the Comfort Tip with your other hand rotate 180 counter clockwise and lift up to remove The tip will tear preventing cross contamination 2 After each patient use return the DentalVibe unit back to it s charging base Note Safe with pacemaker defibrillator when used normally in accordance with intended use INSTALLING REMOVING COMFORT TIP EDA 9 s Infection control protocol for comfort tips A WARNING Do Not re use the Tip Comfort Tips must be disposed of after each patient use to prevent cross contamination and ensure FDA compliance of infection control protocols These tips are porous contain microfilaments and will harbor blood saliva and bacteria Dispose of used White Tip in red bag hazardous waste Injection Technique with DentalVibe 1 Hold the DentalVibe as a retractor in a similar fashion as you would hold a dental mirror It is designed with the same angles for ease of use 2 Activate the DentalVibe by fully depressing the On Off button and then introduce the vibration to your patient by gen

Download Pdf Manuals

image

Related Search

Related Contents

テスラーコイル取扱説明書  Guide de l`utilisateur pour le téléphone portable GX25  The operation of the stair lift Konstanz  Protección de Máxima/Mínima Tensión · TPI    Wooden Camera 152100  Samsung Lavatrice WW80H7400EW User Manual  Handbuch Modulo Pellet  Sony FWD-50PX3/BT Dimensions Diagram  Kit Instruction Manual  

Copyright © All rights reserved.