Home
User Manual
Contents
1. SERVE OVER COUNTERS MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION 9 Pentland Table of Contents a General Safety Instructions 2 Transportation amp Storage 3 General Information amp Technical Data 4 Directions for Installation amp Use 5 Maintenance amp Troubleshooting Brought to you exclusively by 1 General Safety Instructions Below is a list of good practice instruction to ensure the safe use and handling of this appliance Failure to do so may result in irreparable damage to the unit or physical harm to the user e Ensure the plug and the socket are in good working order before connecting the supply e Ensure the voltage and frequency of the mains supply correspond with the information on the rating plate e Disconnect the unit from the mains power supply before any cleaning or maintenance e Do not touch electrical parts with wet hands e Always use suitable tools for the parts to be handled e Avoid letting any tool come into contact with any moving parts fans etc 2 Transportation amp Storage A forklift truck or a transpallet should be used to lift and move the packed product paying particular attention that the weight is evenly balanced to reduce the risk of tipping A set of symbols are printed on the cardboard packaging according to international regulations giving indications which could be observed during loading and unloading operations handling and storage of t
2. edges such as evaporator condenser etc and always use protective gloves Cleaning of Condenser For improved performance clean the condenser at least once a week Before beginning ensure the unit is disconnected from the power supply then proceed as follows e Unscrew and remove protective grill e Remove the dust deposited on the front surface of the condenser using a soft brush and vacuum cleaner When complete replace grill and screw securely Cabinet Not in Use During periods of inactivity remove the products from the cabinet and follow these instructions e Disconnect the unit from the power supply ensuring all switches are set to OFF e Carefully clean the unit as described above e Cover the cabinet with a cloth or cover that allows air circulation around the cabinet Troubleshooting The causes of malfunction are often due to problems that can easily be resolved on site Check the following points according to the problem encountered and carry out the corresponding fix before calling technical support 1 The Refrigeration Unit Does Not Start e Switch to the OFF position and switch back ON again the unit should start again after 2 minutes approximately e Check unit is correctly connected to the power supply 2 The Unit Does Not Cool Sufficiently e Ventilate the room and ensure the unit is away from any direct heat sources e Clean the Condenser e There may be insufficient refrigerant gas or the condenser
3. may be removed in order to join onto another cabinet The ends are made from vacuum formed polystirol and are filled with 40mm thick polyurethane insulation 3 Doors The doors on the appliance are for sealing the lower storage section when not in use The door is constructed of galvanized steel coated with a PVC Lacquer and is filled with 30mm thick polyurethane insulation It also has a magnetic edge around the door for sealing 4 Top The top is mounted on the rear of the appliance and may be used for serving or preparing the goods 5 Glass Screen Fully tempered glass surrounds the outer edge of the counter and encloses it into a showcase 6 Display Light Illuminates the showcase area and consists of a fluorescent tube electric power unit and a power switch 7 Rear Doors 3mm plexiglass sliding doors which are removable and Sliding 8 Shelf Mid display shelf located to the front of the glass Constructed from flat tempered glass 8 12mm thick this may be used to display smaller items or may be removed 9 Screen Located toward the front of the deck this is made of 6mm thick tempered steel and is designed to prevent fogging and lowers the loss of heat through the front glass 10 Evaporator This is a pipe lamella heat exchanger and is part of the refrigeration system There is a dish underneath to collect condensate water 11 Deck This is meant for displaying the products on and is constructed from sheet stainless st
4. eel 12 Chassis This is a three dimensional welded structure designed to support the weight of the appliance 13 Compressor consisting of a hermetic cooling compressor an air cooling pipe lamella condenser axial motor fan and a filter dehydrator of refrigerant gas 14 Power Switchboard Control Unit for the power supply 15 Evaporation Tray Designed to collect condensate water to be evaporated by the heat of the compressor 16 Power Flex Electrical supply power lead 17 Control Panel Main control unit for the operation and regulation of temperature 3 2 Technical Data Model Unit OMEGA100 OMEGA130 OMEGA160 OMEGA200 Dimensions Length Width Height Sg e a e Side Panels eet e s w e of the Shelf oee e p Storage Space Cabinet Weight of 45 2 45 3 boaii Goods Per 1 Shelf Number of Shelves Frequency 50HZ 50HZ 50HZ 50HZ JL opa KEL MR Ke a 3M2 3M2 3M2 Space Pe eee La Input of Lights Cie DA be Consumption Refrigerant 380 Quantity R404A 4 Directions for Installation amp Use 4 1 Unpacking e The appliance should be unpacked immediately to check it is intact and has suffered no damage during transit e Any damages should be reported immediately to the carrier e Do not use sharp tools to cut the cardboard and this may damage the underlying steel panels e Assemble the feet or alternatively the fixing brackets of the marble case e Level the appliance by ti
5. fan may have stopped In these instances contact technical support 3 The Unit Does Not Stop Cooling when It Reaches Temperature e This may bea broken sensor contact technical support e This may be a faulty thermostat contact technical support 4 The Unit is Excessively Noisy e Ensure the unit has been sited on a flat and level surface e Check for any loose screws nuts or bolts e Move unit away from any other units that may be in contact If any of the above fail to resolve the problem contact your technical support centre quoting serial number model number and nature of fault For spare or replacement parts scan the QR code below with your smartphone or reader Alternatively visit www pentlandparts co uk Blizzard Parts www pentlandwholesale co uk Illustration Below is an illustration of the counter as described in Section 3 Appendix 1 1 Omega 202
6. ghtening or unscrewing the bottom part of the feet Remove the PVC protective film from the interior and exterior walls avoiding the use of metal tools 4 2 Putting Into Operation To begin the simple process of putting the machine into operation begin by setting the main switch on the control to I position The light on the control panel should begin to flash After approximately 2 minutes the compressor and the condenser fan should start automatically and the cooling process begins Once the appliance has reached the desired temperature the probe will activate and and stop the cooling operation until such time as the temperature falls out of the reguired range upon which the compressor will start again to regulate the temperature Once the cabinet has reached the desired temperature you may begin to load the appliance with stock do NOT load the unit until it has reached the desired temperature as this may restrict airflow and increase the amount of energy reguired to cool 5 Maintenance amp Troubleshooting Routine Cleaning Before putting into operation all parts of the cabinet must be cleaned Forthe interior of the cabinets a solution of neutral detergent and warm water is recommended using a moistened cloth Dry both the interior and exterior of the cabinet with a soft dry cloth Do NOT use harsh abrasive detergents or cleaning materials such as scourers wire wool etc Use extra caution when cleaning moving parts with sharp
7. he appliances These symbols are as follows TOP FRAGILE Handle With Care DO NOT EXPOSE TO HUMIDITY Units should be stored in an enclosed dry place and be protected from dust and dirt by means of a dust sheet bubble wrap cardboard or similar All precautions must be taken to prevent the ingress of water into the unit or it s packaging It is not recommended to stack these units in storage unless all necessary precautions have been taken to prevent damage and or injury The units may contain glass and as such should be treated with the utmost care Failure to do this may result in breakages 3 General Information amp Technical Data This appliance is designed for the storage and display of previously cooked or packaged food and drinks Serveover counters such as this are suitable for premises of all sizes and can be multiplexed to create longer display areas The unit comprises of a lower storage area and an upper glass display area Both areas are separated by the deck but are controlled by one refrigeration system 3 1 Detailed Description The basic parts of the appliance can be seen on the schematic at the rear of this manual and will correlate directly with the following key 1 Body The body is made of galvanized steel with a PVC Cover and has 50mm thick polyurethane insulation Both cooling sections are contained within the body 2 Side Panels These are designed to close off the cabinet at either end they
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi 綿菓子機取扱説明書 GREASE - Alcoa Interlogix NX-1192E 6 - Provincia di Torino BASES EQUIPOS DERMA Y OTORRINO - HOSPITAL Copyright © All rights reserved.