Home

TINALab II Specification

image

Contents

1. TINALab Il Specification SYNTHESIZED FUNCTION GENERATOR WAVEFORM OUTPUT 10V 5V into 50 Ohm Nominal Impedance 50 Ohm 15V mplitude Frequency range D A CONVERTER Resolution 10 12 bits lt 0 1 of full scale monotonic Update Rate 40 MSPS WAVEFORM MEMORY Min 65 536 16bits DIGITAL OUTPUTS Connection all 16 bits wired to a shrouded male connector 8 least significant bits wired to 2mm sockets Compatibility 5V tolerant devices 5V TTL CMOS 3 3V LVCMOS Short circuit protection in range of 15V ANALOG INPUTS A D CONVERSION 10 12 bit no missing codes Sample Rate non repetitive signal 20 MSPS channel Equivalent Sample Rate 4 GSPS channel repetitive signal SYSTEM CHARRACTERISTIC Bandwidth 3dB dc 50MHz DC coupled 2Hz 50MHz AC coupled FRAME MEMORY CHANNEL min 65536 16 bit Digitized analog and or digital VERTICAL MEASUREMENT RANGES Scale Factor 5mV div 20 V div 10 s div 10ns div TRIGGER SOURCE Channels A B external 16 8 bits trigger pattern DIGITAL INPUT Connection all 16 bits wired to a shrouded male connector 8 least significant bits wired to 2mm sockets Compatibility 3 3V CMOS TTL 5V CMOS TTL MULTIMETER A D CONVERSION 12 bit Measurement Range Impedance Bandwidth 20kHz AC CURRENT 1 1A RMS DC CURRENT 1A RESISTANCE 10Ohm TMOhm INTERFACE USB 1 1 full speed RS 232 115200 b
2. asure voltage and resistance with the multimeter Attention This input does not work unless a TINALab II Multimeter Card is installed COM 2mm socket connector Common ground of the multimeter measuring V I This ground is independent of all the other ground connections of the instrument Gnd Agnd I Zmm socket connector Input terminal to measure current with the multimeter Attention This input does not work unless a TINALab II Multimeter Catd is installed Power DEO USE RS 232 m 2 4 26 27 28 29 30 26 Reset button 27 User Port shrouded male connector Reserved for further 28 29 development USB interface Attention All terminals of the USB interface are galvanically connected with the instrument and subsequently with protective safety earth potential RS 232 serial interface Attention All terminals of the RS 232 interface are galvanically connected with the instrument and subsequently with protective safety earth potential 30 Power source connector Accessories supplied TINALab II Install CD TINALab Basic TINALab User Manual External Power Supply Fortron Source Model No FSA30P32 S AC Power Cord optional USB A B Cable 1 8m RS 232 Cable 2m optional The cable contains 4 screened lines connected 1 1 TINALab II RS 232 connection 9 pole D SUB female is determined as follows a 1 TXD data from TINALab II to PC RXD data from PC to TINALab II Groun
3. aud full duplex 8 N 1 DC POWER SUPPLY Fixed DC output 05V Cd 25 10 EXTERNAL POWER SUPPLY 100 240VAC 47 63Hz 5V 3A 15V 0 8A 15V 0 8A Dimensions W x H x D 291 x 75 x 199 mm Panel elements of TINALab Il 80 t o 6 imine ijo 9 v 9 gt 8 DOG Power LED 15V programmable power supply output Attention For the time being the supply delivers only fixed 15V 5V fixed power supply output Digital ground Analog ground 5V fixed power supply output 15V programmable power supply output Attention For the time being the supply delivers only fixed 15V 8 Ch A Input 2mm socket connector This is the signal input for channel A 9 Ch A Input BNC connector This is the signal input for channel A The outer ground connection is galvanically connected to the instrument ground and consequently to the safety earth contact of the line mains plug 10 Ch B Input 2mm socket connector This is the signal input for channel B 11 Ch B Input BNC connector This is the signal input for channel B The outer ground connection is galvanically connected to the instrument ground and consequently to the safety earth contact of the line mains plug 12 Ext Trg Input 2mm socket connector This serves as external trigger signal input if external triggering is selected 13 Ext Trg Input BNC connector The serves as e
4. d reference potential connected via the power cord with protective earth CTS clear to send 8 RTS request to send 7 2 Oscilloscope Probe Kits K amp H LF 101 8 BNC Test Lead K amp H LF 56 9 Breadboard K amp H RH 21 10 Test Leads 15cm Standard color K amp H KLG 0 65 2 11 Test Leads 30cm Standard color K amp H KLG 0 65 2 12 Small wire set 14 length each 5pcs K amp H SWS 03 13 Test kit 200Ohm 0 6W Metal film 1 10nF 400V Foil capacitor 10 8 2mH 0 1A Inductor coil 10 Note Subject to change without notice TINALab II Specification DesignSoft Inc REV E www designsoftware com
5. xternal trigger signal input if external triggering is selected The outer ground connection is galvanically connected to the instrument ground and consequently to the safety earth contact of the line mains plug 14 50 Output 2mm socket connector Short circuit protected signal output of the function generator 15 50 2 Output BNC connector Short circuit protected signal output of the function generator The output impedance is 506 and the maximum output amplitude is 20Vpp open circuit or 10 when terminated with 50 Q 16 Digital Inputs shrouded male connector Signal inputs of the Logical Analyzer The inputs are protected against external DC voltages up to max 15V 17 Digital ground 18 Digital Outputs shrouded male connector Signal outputs of the Digital Signal Generator The outputs are protected against external DC voltages up to max 15V 19 Digital ground 20 Digital Outputs 2mm socket connector Signal outputs of the Digital Signal Generator The outputs are protected against external DC voltages up to max 15V 21 Test Card 50 contact card edge Slot for test cards Test cards are ready to use circuits for measurement experiments manufactured by DesignSoft Inc 22 Digital Inputs 2mm socket connector Signal inputs of the Logical 23 24 25 Analyzer The inputs are protected against external DC voltages up to max 15V V Q 2mm socket connector Input terminal to me

Download Pdf Manuals

image

Related Search

Related Contents

DeLOCK 2.5“ External enclosure IDE HDD to USB 2.0  Handbuch für Ruf-/Anzeigetableau-Knoten CANsmall  KX-VC300 KX-VC500 Guía del usuario del Servicio NAT Traversal  Zebra 105936G-032  light source operation  Système de contrôle urinaire AMS 800  MANUEL D` INSTRUCTIONS  Betriebsanleitung BCX2500 BCX2510  PRIMERGY BX600 ハードウェアガイド シャーシ編  Gigaset DA710  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.