Home

THseries Touch Screen

image

Contents

1. Download Port M FLC Port 4 click the button to see the lamp ON OFF Turn off the reverse button turn on the reverse button When click the reverse button the PLC output YO will switch ON OFF at the same time 6 5 Download the project There are two modes to download the project into the TH USB port and USB cable COM 1 port and Xinje special cable 1 USB port downloading Connect TH USB B port and PC with USB cable power on the TH click to download the project 2 COMI port downloading Change COMI to download mode please refer to chapter 4 3 power on the TH click to download the project Application 7 1 Adjust the touch area The touch area adjustment function can make the component touch more precise Yy The adjustment steps Step 1 turn on the DIP switch 3 then power on the TH again 1t will show the following screen 1 2 3 4 Calibrate the touch panel Repeat as the target moves around the screen CFF O Turn on switch 3 Click the center of the adjust cross Step2 After clicking the cross center the adjust cross will jump to the second position Keep on click the cross until the cross jump to the last position 5 Calibrate the touch panel Repeat as the target moves around the screen N Pj Step 3 Please see the detailed
2. 7 4 THA61 M exterior dimension 311 0mmx234 0mmx48 0mm mounting dimension 302 0mmx225 0mm 234 0 oo o 222 O 000000 000000000000000 302 0 223 0 225 0 3 3 Installation and using environment 1 Install reguirements TH has four ferric mounting racks when out of factory there are two square holes on the up down side of TH use mounting rack to fix the TH with control cabinet In order to avoid TH temperature too high after long time working please keep 10cm space on the up down and 5cm on the left right side of the TH when installing AEREAS SET rd ERASE EN Install panel Fixed bracket 2 Install steps Stepl Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet Step2 Add airproof circles in the airproof slot when installing Ste p3 Insert the bottom of TH into the mounting hole of control cabinet Step4 Insert the install rack into the fix hole of TH then tighten the screw Ste 05 Connect TH and PLC with communication cable NOTICE The communication cable can be offered by the supplier or made by user according to the connection map input 24V DC power to start working
3. E Screenl Bich seh e fey GA ek e B ee A BLS A MS AB O O ade h ew we ea pe S kim gm te e Ka AG Eee eine Ree ee Ae eRe oo ER Pees ee dese sinmedi cara he ROEM Ga Sie RE oe we Sa yA Property J mm Y Lock Public Unit System Cut Copy Delete Save Template Advance Optimistic Unlock All m Screenl Be az 3 42 4h Ge te ce Ge Se ce Oe te te EE Ee GIG WG EO GRO E 6 S 6 UIS www yaaa a R R ee EEE BEBO ee eS S SS B Lace nh eee CSR RE OO Oe ee Oe er 5 5 S S VATA ver e V GE GE O DD AN A AN a ee Se Se O G OM Na PRR KH KR SR SRS THM SRR REE RRR SE SSS eee He REESE HP HEE EASES HHH HE SRE RE BHM AO Step4 Simulate offline Click to simulate offline your project You can see the photo motion track Step5 Change the animation property Right click the photo then select animal prop gt Mm a Legos Bans ge wae eae cede gas a ar a ere AB Property Sh i PEM BM5 5 B Pee Ae Animal Prop ll a a eed a e gt Al nore o non ccoo ano fate jj ssmammmmusuasnna i Pilas pir e ma Syst em A of Kee A eel gtr aint tas a A AE TS po X A S Cut Ss ba ew ws S amp BS amp amp E R OS a ah de See Gee Gee ae Copy w a di kw we e oat a Delete eee ees E See Bye a ae aR WR AE Save ya SSS 6 4 RR sm AB A y N Leni Jde oi aS ewe owe ee ww ks si Advance Deptt seman we san eo i ee ieee Unlock All 4 aren MN a The
4. 2 click the reverse button to see the ON OFF switching of the lamp L severe 9 Turn off the reverse button turn on the reverse button Thus the simulate operation is finished 6 4 Simulate online By connecting the PLC and PC it can read the data from PLC simulate the operate of TH in touchwin software Do not have to download the project into TH you can control the PLC in your PC Make sure the connection is correct between PLC and PC the com port setting is right NOTE only Xinje PLC support the simulate online function with TH 1 connect Xinje PLC with the PC via serial port 2 click the to enter simulate online It will show below message It means the simulate online is not registered you only can use it for 2 hours If you want to use it longer please contact Xinje company to get register number 3 click ok to enter simulate online screen Right click the screen to show below menu Log About P Com Fort Exit Log log on time and history record About the version information of autowin Com port the serial port number of your PC which is connected with PLC Register register to get user right Exit exit the autowin If showing the following message it means the connection between PLC and PC is not good or the serial port number is wrong communicating PLC Fort StaMO 1 In this example we use TH PLC port and PC serial com port3 so select PLC port com 3 Com Port
5. Produce CSV format Data export to the registers file start from PSW400 Next we will introduce the each process 1 produce the data source PSW300 PSW300 10 every 1 second Open the Touchwin software click Function Field Mode Function Position Act Mode f Start Screen Coil Spring Time Sec 1 4 Run immediatel Select time 1 second Continue First Scan After Power a r First Sean After Down e E Time Continue Coil Limit Function Field Mode Function Position Funetion Al Arithmetic set Coil PEW3s00 FS1300 10 Reset Coil Add Reverse Cojl Add the arithmetic Copy Coil o Ei PSW300 PSW300 10 Modi y set Data Copy Register User Input Open Window Close Window Delete Down Scheme Up Scheme Data Block Transmit Process Code Import CSV Data Export CS Data LA Y Please see the TP touch screen manual for this content 2 data collect use history data map to collect the data every 1 second use PSB300 to control if it 1s need to collect Click add it in the screen change the trend source tab Histroy data map Histroy Trend Source Trend Data Color Station Device PLC Port y virstaNO o Station Object Object Trend Source Display Save Color Font Position Add Delete D Object Min Value Max Value 1 PSW300 0 1024 r
6. ma Device ID 1 there is one U disk device Path File SC csv Path File name the file to SJDC csv re export Fix Name Goose the title rro Name add automatic add number after name a TR C named by date Data tab Destination Data Save Control Date Time Register capacity 5 Register capacity 10 Register mode SL Li 2DE ve Register mode loop to correspond to the history trend map Title data valuel Format f Tec f D Hex A Delete Float Fl Insimedk Move up Move up Data type Word Bit length 65 4 Move down dowa Float length E Format decimal Save tab Destination Data Save Control Date Time Save the data in PSW400 Object Obiect psw 400 Date time tab Destination Data Save Control Date Time W Date Time Date Formati yrr Date time export the date and time to the csv 1 file Example 2003 10 8 Time Format MM 55 Example 13 28 32 Now the data export has been done Via the simulate offline you can monitor the data change and operate the button Data export example y Turn on the button to start gt the history data map A a x data data export Click the button to export the data into U disk The operation steps Step 1 make sure the TH is connected to object device Step 2 click ON OFF button to start the data collection in history data map Step 3 click the data
7. 3 Environment Please use TH series touch screen indoor Do not use TH in below environment Inflammable gas steam dust fast vary temperature high humidity it may cause moisture inside TH 4 Power supply reguirements TH series touch screen use DC 24V power supply only The permitted voltage range is 20V 28V The connection is as below E Se f N Z I X XK i k XK 2 N 7 SO e o PNV ov ee Besides 1f connect high voltage or AC power supply with TH the TH may be damaged and cause electric shock to human body NOTE if use the DC 24V output of PLC to drive the TH make sure the PLC has enough current to drive the TH 5 Maintenance and cleaning Caution Please do not open the back cover by yourself Please do not analyze or change TH by yourself Please cut off all the power supply while observing the TH Please do not touch terminals after power on otherwise 1t may cause electric shock Do not hot plug the cable or pull the cable when communicating 1t may destroy the cable Please periodic check installation and screws to avoid falling off Please use TH series touch screen in the certain conditions according to instructions Keep the cleanness of touch area in order to keep touch sensitivity Caution Please use clean cloths with little detergent or alcohol to clean the screen Neutral detergent without acid alkali is recommended Ke
8. 224 4 170 8 45 5mm Mounting dimension 211 4 157 8mm 24 THA61 M tem THA61 M Input voltage DC20 DC28V Consumption current 630mA Momentary power off Less than 10ms Electrical allowance Withstand voltage AC1000V 10mA 1 minute signal and time Insulated impedance DC500V about 10M signal and time COM1 Support RS 232 RS 485 COM2 Support RS 232 RS422 RS485 Interface USB1 USB A accord with USB2 0 USB2 USB A accord with USB2 0 USB3 USB B accord with USB2 0 Operation temperature OLI 50 C Reserve temperature 20 60 C Environment Environment temperature 20 85 no condensation Withstand oscillation 10 25Hz X Y Z each direction 30 minutes 2G Anti jamming Voltage noise 1000Vp p pulse lus 1 minute Surrounding air No corrosive gas Protection construction IP65 Type 65536 true colors Screen size 10 4 inch Use life More than 50000 hours 24 hours running when surrounding temperature is 25 C Screen l AA Resolution 640 480 specification Contrast Non adjustable Character Chinese English Korean Japanese Character size Any size and font Touch panel 4 wire resistance mode M emory Screen 128MB Construction Cooling method Natural air cooling Exterior dimension 311 0 234 0 48 0mm Mounting dimension 302 0 225 0mm 3 Hardware 3 1 Hardwar
9. T JSULEN BLAU COM2 Omron PLC Select the correct PLC type in the list and set the communication parameters Please select port PLC device Thinset Series S Communication Parameter x E Baudrate Data Bit Thinget VO Series Inverter r r m sn api Mi tenbichi EY Series 4800 38400 Bits obits Mitsubishi Q Series gt Thinget FC Series C 9600 115200 Stop Bit Omron CP CJ US Series e SADE 187500 1Bit 2Bits Panty check Schneider Micro Heza Twido f None f Odd fe Even Matsushita FFO FF LS Master k CPU Direct ho vw ait Com Para 19200 8 Even 1 Communication Time 1 MSEL Setting M SendData Vir Station Retry times 3 gt q Please refer to TP connect with PLC for the details of TH communicate with PLC Communicate with freguency inverter TH can communicate with various brands of freguency inverters For the brands which are not in the list user can select Modbus protocol or user defined protocol Mitsubishi FR series inverter Inovance MD series inverter Bosch Rexroth Indracontrol LAO COM2 Please refer to TP series touch screen application examples for the details of TH communicating with frequency inverter Communicate with meters About the communication between TH and meters users can select user defined protocol or Modbus protocol amp communicating with meters 4 5 USB A port Please refer to TP ser
10. The following terms should be done when using download function 1 Turn on switch 2 in DIP switch group to make the COM 1 in download mode 2 Please use the cable provided by Xinje company Step 1 Turn on switch2 when TH power supply is cut off 2 Power on TH connect TH with PC via Xinje download cable to download project 3 After the download process is over cut off the power of TH then turn off the switch 2 4 Power on the TH again the project will run normally Xinje download cable WouchWin Make sure your PC has serial port or USB port use USB converter tool connect it with COM1 then click E PC serial port in the software to download data The pins definition is shown as below TH COM1 port Figure Download cable connection Forced download After the download is completed if the TH can not display the screen normally you can try forced download mode to update the system Step 1 Cut the power of TH turn on switch2 2 Power on the TH connect the cable then download the CN project 3 After the download is completed turn off switch2 then OFF power on the TH again Ag About the TH download details please refer to the chapter build a simple project project download Communication function COM1 port has strong communication functions The default mode of COM is communication mode PLC Send da
11. a e a S 24 0 Download the pro SC ini eisi im i a hb A i hdr aria lr n A r lll a 25 S pi Ca Oa buana Ka Ne an a is sia sikiyim ina tan Beat 26 Il Adjust the TOUCH ME ia a i i i NI Gage l mo 26 12 Photo AD PCa EO Ka i ia kai AN i Ss 28 Fe Debusand don Modd estada a a i daub i i a a i a 31 1210 AL DAC ED oda aa ai a a a aa a Seyi 32 pul Data EXPO benua an ti 32 7 42 Import the CSV ata ABK BA SEA dinleme liler 42 8 IHserlestouchscreeninterlorobjlecis 50 1 Summarize Xinje new touch screen TH series are based on TP series products It not only has the language characters editing data display monitor and alarm functions but also has 65536 true color LCD which can bring you brand new vision enjoyment It has the advantage of large capability for data duplication and friendly user interface It provides perfect humanized solution for industrial system make it easy to control the system The function compare between TP and TH Function compare 3D Adjust Two ports Series Font USB data USB data Colors picture the touch Animation Password communication ae setting download duplication library area independently TP 256 V I V TH 65536 V V V V V V 1 1 Performance characteristics Display Adjust function for touch screen Various models product size from 4 7 to 10 4 Rich colors 65536 TFT true color
12. add the register in the list PFW Data x Start 300 End 400 Add Modi fy i Delete Change the range then click Modify it will show below message click Yes to confirm the modify A The pre setting data beyond the range will be lost while the data in the same range will be held continue Step2 set the value in the range Double click the PFW range 1t will show data setting window PFW XI PFW O000000400 T 0 0 0 D D 0 e l e E Display number can select decimal or PFW 000000420 0 0 0 O 0 0 0 hex PFW 0000004 30 T i 0 0 0 0 0 Ll PFW 000000440 0 0 0 0 0 0 0 Set FF set all the data to FFFF PFW O000000450 0 0 D D D D D Reset 0 set all the data to 0 PFW 000000460 0 0 0 0 0 0 0 TT TAT n T m m m mn mn Y Ng lt gt Display fe Dec Hex Reset 0 Set FF Cancel Step3 download the project into TH Please note PF WO PFW 256 are occupied by the TH system please select register start from PFW 257 10 setting Para tab Device Font Project Para Alternation Clock Fanel Screen Start Screen In Pazsowrd Leve Password Screen Save Latency Time After 3 Minute T 1 Close LCD Show yy Screen select the start screen number when TH is power on Password there are 9 levels password the level 9 password has the highest priority The higher level password can used to all the elements of lower level password The password is u
13. data several times at the same day it will add the data title in the file automatically For example 36 ml a Ya Length Width Height Qty a Microsoft Uffice gt gt F 1 KB d 20 30 10 12 Export the data the first time on 8 18 2009 gt 20090818 csv ERO L Y a Microsoft Office OON 20 30 40 12 L p Length Wdth Hight Gy 32 41 37 13 Export the data the second time on 8 18 2009 2 Data tab Destination Data Save Control Date Time Register capacity 10C Register capacity import register guantity Register mode le Loop Line Register mode Loop use with real trend map history data Add Title Temperature map time trend control sample save Line export the data in the registers to CSV file It is used to the recipe and data arrays Format fe Dec I C Hex W Delete m l wo E Add delete move up move down Add the data titles select the export data format Move up Data type Word and type Bit length G O Move down Float length iC g 3 Save tab Destination Tata Save Control Date Time Save the data in touch screen internal Ubject registers Object AF 4 Control tab Destination Data Save Control Date Time W Execute status MO MW Execute result no V Execute process no This tab is used to control the export Execute status to show if it is in exporting state via bit state If the bit is ON TH is e
14. ei i i rad tios 7 1 1 Pertormancecharacteri ts oo siai sia i O lamunan 7 ZW GF TOM an Maen Ai a aa a salli a Ai O 8 2 General SMe CL NE ANON Las ia a i k i i T RAN AU 9 WELO TO 10 2 2 A ua i so i a a a a a r a ay 11 23 AAG A O I e a a ka a a V a tase ee a aaa es 12 2 IA E M ri i i S 13 EARN AE us Ia ins aina i e a a ie na i D a ar eo 14 del Hardware SECU UES ad aa ia i kain ia o o bana 14 A BELU IN 15 3 3 Installattonandusingenvironment 17 de terrace and GS WI ias io e i tak ia D i i a i A A a i Oil 1 A Ae ME O GUC HOM kon iii a a a i i la i Ni a i amli i a 1 e a i a a a I a a Red cea a a o a a oieadotauds 1 S ON DOLE a gel e re ii hn mun i G Gn i r i t min af 1 ACO O rt rn an rn ME MR A YO EM 4 4S USD OT oo aa ia i A A a a i a una a 5 O UIS Bee ON di ai i a a ia r a i i iden D a r a Ni A D 6 ON A is ad al i a nala Gal Aaaa A a E a o A A A A al 8 A DA AON casera alate a eee crs AL I Sinn Re Da oes Seneca a a sas Aa 8 3 2 THE CONSIUCTONOF Touch Wih ionisasi 9 A ee RN i i a a a ANN 9 320 POPS CE Delle ia ai acura a a a i i a o ila KERR Dz 9 IA A aaa osios a ika ia a aid au aaa as 11 3 3 TOOL DAL psn aaa aa a a a i a ala a a a a a AI 17 6 Makea Simple project ederk ais Na i ia a a ia i i a atada detalle 20 DLL Build A EL Anik s ais Gi as i ar A ak ai a A as 20 0 2 Make A Simple Project ausi A A AA 21 gt SIMU ALS 0 EK NE Ma man i i a alin a a i 23 OS Il ate AA a a E
15. export button the U disk device LED starts to flickering it means the CSV file is being produced if the LED ends flicker the export process has been finished The CSV data is shown as below data value date time Sa Mi ersa Office 60 2009 9 14 10 12 12 LU SPA dei au lila LGL A LA 30 000 518 DERSE LS LOD 0083 14 1001516 lt B gt Data export in line mode In industry system HMI is seemed as control and monitor terminal It can be used to set all kinds of parameters directly In order to check the history data use data export function to complete the data management In this example using data export function to complete the parameters recording Purpose realize parameters setting by data input button and data export by data export button The process is shown as below R ealize by data input button 7 1 Realize by function button export CSV data Data input 1 PSW500 Data input 2 PSW501 Save in CSV format file Data export button Data input 3 PSW502 Data input 4 PSW503 Set the head address to Data input 5 PSW504 PSW500 Next we will introduce how to make the project in two parts Part 1 input the parameters Put the data input button on the screen change the address as the following Data export example Faral Para Paras Farad Paras ld LI Ed Ed ba PSW500 PSW501 PSW502 PSW503 PSW504 About the data input button please refer to TP series HMI manual Part 2 abo
16. get and read hand the manual to the NOTICE end users Please do not bundle power line with communication cable or let them too close keep at least 10cm Please do not install module or change the wire Otherwise it may cause malfunction error action damage or fire Please shut off the power when there is abnormal smell or voice in TH products The short sound made by buzzer after power on is normal Do not strike the touch panel with a hard or sharp object or press on the touch panel with too much force or with pen screw since it may damage the touch panel and cause damage Please tighten the screws when install the products to prevent from falling off Please transport store set up install and maintain the products correctly otherwise the touch panel may be damaged IN DANGERS Confirm the rated voltage of TH and connect correct before power on Please do not touch the terminals after power on to avoid electric shock Please do not open the cover board Please cut off all the power when installing or disassembling the products or it may cause error action and malfunction Please use TH touch screen in suitable environment conditions according to instructions otherwise it may cause accident Please do not use the products where there is high frequency radiate high magnetic field or other interferences Catalog Pra le 3 So A A i Ke d A i A i o A e A ss i As i gann 4 be R LZ e ai
17. motion Calibrate the touch panel Calibrate the touch panel Repeat as the target moves around the screen Repeat as the target moves around the screen 1 click the center of the cross 2 click the center bf the cross on the top left Calibrate the touch panel Calibrate the touch panel Repeat as the target moves around the screen Repeat as the target moves around the screen NS 4 click the cent of the cross on the right 3 click the center of the cross on the left bottom bottom Calibrate the touch panel Repeat as the target moves around the screen S click the center of the cross on the top left to finish the adjust process Step 4 When finished the adjustment the result is as the following Calibrate the touch panel Calibrate the touch panel Repeat as the target moves around the screen Repeat as the target moves around the screen X Adjustment process is failed Please do again Adjustmen
18. of the screen Name the name of the screen Message the description of the screen to modify the screen property Select the screen in the project bar right click and choose cut copy or delete y window operation 1 right click the window insert in the project bar Input the window ID name and message E fat Project fi Screen Window x ID 1 width 160 Name Window Height 120 Message Frame Single Back Color L 1 Screenl E ere gt Mi Print 2 window cut copy delete Geros select the window in the project bar right click to select cut copy or delete window Alfa Project E H Screen po ij 1 Screenl lap Window E Eq di Alarm di Print Cut Copy Delete Property a eee 5 2 3 Menu 5 2 3 1 File The file menu is shown as the following JAE Edit View Part I New Ctrl 1 New Build a new file Open Ctr1 0 gt es a a 2 Close Ctrl g Close Close a file Save Ctrl s 2 E se a ane a dace ds Crell Save as Save a file as another name and pat 6 Download to download project into TH Download Ctrl D l l l l normali ERER 7 Run online connect PLC and TH Simulate online n TH software Run ftlLine M Ctrl PFW Set P Ctrl P 8 Run offline simulate offline amp simulate the touch screen Setting Ctrl T action in the software Build SCADA Exit 9 PFW set Stepl set the PFW register range click Add to
19. two curve in X Y direction XY curve Ex Display the value in line point and line point Time trend control Display value in certain time space Event button Use with event curve realize flip confirm and clear operation Alarm list Show the inverter alarm information in the list Display real time alarm information when the alarm DEDE E event is free the event will be deleted automatically hi ei Display many alarm information and event happen pray y time Common grid control Display a group of register in the table Display a group of register in the table support time information table Data grid control To collect the object data no limit for the sample quantity and time save the data in TH registers Save the data in TH register and export to object device as CSV format file Sample save Sample export Align left Align left the objects Align center Align center the objects Align right Align right the objects Align top Align top the objects Align middle Align middle the objects Align bottom Align bottom the objects Zoom out Zoom out the screen Zoom percent Zoom percent Zoom in Zoom in the screen Grid Display grid in the screen State change Switch button state display Dynamic picture state Switch dynamic picture state displa selection y P Play Public unit Use the unit in all the screens Priv
20. 00 000 16 18 18 00 groups 900 00 ooo 000 16 16 16 groupT ooa 000 ooo eco 16 16 18 ooo groups ooo ooo cool oool 16 16 16 ooo groups 000 000 oool 000 16 16 16 ooo eroro 000 ooo ooo 000 16 16 16 connect the mobile device and TH click the import data button monitor the data in data table Name Date time Group 2009 08 10 120 100 10 Group 2 2009 08 10 130 100 10 Group 3 2009 08 10 140 100 10 Group 4 2009 08 10 150 100 10 Group 5 2009 08 10 160 100 10 Group 6 2009 08 10 170 100 10 Group 7 2009 08 10 180 100 10 Group 8 2009 08 10 190 100 10 Group 9 2009 08 10 200 100 10 O CO LL LO UM E GO NI Group 10 When the import data No 0 or 1 the data table is shown as up 2009 08 10 210 100 10 NO Name Length Width Height Qty Datetime 0 Group 1 60 12 10 25 2009 08 10 210 100 10 1 Group 2 60 20 8 35 2009 08 10 221 10 10 2 Group 3 65 10 10 20 2009 08 10 23 101 10 3 Group 4 65 12 5 15 2009 08 10 00 10 10 4 Group 5 65 18 15 15 2009 08 10 10 10 10 5 Group 6 65 20 8 30 2009 08 10 OO 10 10 6 Group 7 70 8 8 18 2009 08 10 03 10 10 7 Group 8 70 16 10 18 2009 08 10 04 10 10 8 Group 9 55 20 8 20 2009 08 10 20 10 10 9 Group 10 60 12 10 29 2009 08 10 211 10 10 When the impo
21. 1 baud rate 4800 96001 1 9200 58400 1152001 1187500 PFW21 COM 1 data bit 70 8 PFW22 COM stop bit O 1 bit 1 1 5 bits 2 2 bits PFW23 COMI CRC O None 1 Odd 2 Fven PFW24 COM 1 station NO PFW25 COM2 send delay Unit ms PFW30 COM2 baud rate 4800 96001 119200f 58400 1152001 1187500 PFW31 COM2 data bit 70 8 PFW32 COM2 stop bit 0 1 bit 1 1 5 bits 2 2 bits PFW34 COM2statimNO LO PFW35 COM2 send delay Unit ms PFW60 Level 1 password PFW60 PFW61 PFW62 Level 2 password PFW62 PFW63 PFW64 Level 3 password PFW64 PFW65 PFW66 Level 4 password PFW66 PFW67 PFW68 Level 5 password PFW68 PFW69 PFW70 Level 6 password PFW70 PFW71 PFW72 Level 7 password PFW72 PFW73 PFW74 Level 8 password PFW74 PFW75 PFW76 Level 9 password PFW76 PFW77
22. E Save Save the file B Cut Cut the element EEE Copy Copy the element Paste Paste the element O B Undo Undo the operation m Help Check the software version information Text Input static text BP Dynamic text Display the text according to the value of register support 16 texts set register value as 0 15 r ar Variational text Display the text according to the value of register set register value as user need 2 2 81 Jo jeje Po Lamp Display the ON OFF state of switch Button ON OFF the bit element Lamp button Combine the function of lamp and button Screen jump Jump to object screen Digital display Display the register value alam dpi ge e ini ease vale when Text display Display characters in multi registers Digital input Input the data in the register Text input Input characters in the register Set data Set data and used in arithmetic Digital keyboard Digital input keyboard ASCII keyboard Character input keyboard User input One input button of keyboard Bar Display the register value in bar picture Dynamic map Display the map according to the register value support 16 maps the register value is 0 15 Call window Call window according to the value in the coil or register Window button Control the open close of the window Download recipe Download the recipe into object device Upload recipe Upload the recipe into TH re
23. Example 2009 10 8 Time format H MM ss Example 15 05 53 Step4 show the import data start from PSW400 in data table El Change the parameters Object tab Object Common Column Position The object is PSW400 the same to the data import address Station Device Noe m i rrari Ek Eiht VirStaNO 0 Station Object Object psi ano Common tab Object Common Column Position ALL Records MW Static Field i Titl e oo Fage Records BAR Ti LLE Mame Title Height Width 50 Set the all records page records as the left Cell Height 20 aaa window Iw Use Title W Bold Border Tite Font gan Font M Auto Add Field Title im Width 30 Column tab Object Common Column Position Circle Buffer Add Tana Delete Title Width Data Type Format Add the text as the left window Length po WORD WIHT fidth E WORD UIHT Hei ght 50 WORD IIHT Set the date time item to time format Oty S0 WORD UINT Date time o0 TIME H M 5 The data table is finished please see the following screen Data import example Ty BE Ey Execute status O Execute result 00000 HO T Nano ongth Width Feien Qty Date tine ooo grourt eo ooo 000 000 16 16 16 ooo erour2 000 Toon ooo 000 16 18 18 Execute process 66060 q mp Pap Import data No 4 sa Step5 ooo erod 000 000 000 o00 16 16 16 ooo sroups 000 000 0
24. VisPSW Num the PSW quantity in data input PaPEW Mum 4096 Cache Num Cancel Device tab Para Alternation Clock Fanel Device Font Project ie Single Host Net Slave Net FLC Port Model Thinget AL Series F ar am 19200 6 Even 1 a Download Port Model Unse Downlad Fort T Font Para Alternation Clock Fanel Device Font Project Demo String data display area PriPSW Num the PSW quantity in history trend map real time trend map area Cache num PFW register quantity Single host net slave net TH communication mode PLC port TH PLC port connects device type change the communication parameters by Download port TH download port connects device type change the communication parameters by Set the font of the letter in the screen Project tab Para Alternation Clock Panel Device Font Project Hame Project Author ni 11 Build SCADA 12 Last The latest files operated by the user 13 Exit Quit the Touchwin software 5 2 3 2 Edit Edit View Part Tool Y q Replace Ctr1 H 1 cut copy paste undo Record the project name author and remark It realizes the SCADA function in windows Build the SCADA file and double click it to simulate online please refer to the chapter make a project simulate online de E Cut copy paste undo Public unit private unit these operations are used to the elements in th
25. WouchWin TH series Touch Screen User s manual Xinje Automation Co Ltd Preface Thank you for buying TH series touch screen made by Xinje Electronic Co Ltd this manual should be read and understood before doing relative operation n This manual will guide readers in the correct operating and maintaining TH series touch screen Also this manual refers to the application situations operations transportation storage set up installation maintaining and so on n This manual mainly contains three parts hardware software application Hardware Part contain the characteristics specifications dimensions installations and communication connecting of TH series y Software Part introduce how to use the edit software Y Application Part illustrate the examples make users to know TH better Personnel This manual is fit for following personnel Y End Users Y Engineers y Technicians Please read the safety notes carefully before using the products If you have any questions please contact us use the following methods Tel 86 510 85129136 221 Fax 86 510 85111290 Address 4 Floor Building 7 Original Industrial Park No 100 Dicui Road Wuxi Jiangsu province China Safety caution Please read the manual carefully before using Make sure your operation is correct and safety The following contents are only aimed at TH series products Please keep the manual properly put in the location easy to
26. a group by input the start ID The CSV file in the SD card 1s SJDR csv SIDR csv a I Microsoft Office F 1 KE 40 8 10 15 2009 8 10 12 10 10 40 10 10 18 2009 8 10 13 10 10 40 19 10 30 2009 8 10 14 10 10 45 8 6 25 2009 8 10 15 10 10 45 10 5 20 2009 8 10 16 10 10 50 10 8 20 2009 8 10 17 10 10 v5 Iz 10 15 2009 8 10 15 10 10 55 14 10 30 2009 8 10 19 10 10 DD 20 5 20 2009 8 10 20 10 10 60 Le 10 25 2009 8 10 21 10 10 60 20 5 3D 2009 8 10 22 10 10 65 10 10 20 2009 8 10 23 10 10 65 12 5 15 2009 8 10 0 10 10 65 18 15 15 2009 8 10 10 10 10 65 20 6 30 2009 8 10 2 10 10 T 8 B 18 2009 8 10 3 10 10 TO 16 10 18 2009 56 10 4 10 10 In TH touch screen the data store address starts from PSW400 The realize steps Stepl use function button or function field Set as the following Function Button Function Button Limit Color Position Mi y Releasing bd Import CSY data Modi y Delete Sereen Jump J o o S set Data A wo g A O Copy Register TIT Data import TTT User Input Da m ti RE ee ee m Password E Digital Input Object Display Input Font Color Position Operate Object Station Device SEA T VirStaMO Station Change the object to PSW500 and be constant with the following Object import data dynamic appoint Object Psw FOO address Indirect Data Data Type Word Step3 double click impo
27. animation property includes coordinate and control 1 Coordinate Hove Animal Coord Contrel E Point X 325 Y 110 Escape Time UU 1Second Key Point gt 42325 12230 yi 1110 Escape Time OU 1Second Key Point gt 15009 T5230 Escape Time 00 1Second Key Point 4 685 Y 100 Escape Time UU lSecond Key Point A 325 1 100 Escape Time 00 1Second Key Point 15325 Y 125 X the position on X axis Y the position on Y axis Escape time the time that the photo moves from X1 Y 1 to X2 Y2 Key point X Y the coordinate of every motion position You can click the X Y position and the escape time in the list and modify them 2 Control Coord Control Enable Ctrl Reset Ctrl Enable control the animation by bit signal When the rising edge of the signal is coming the animation will be activated Reset control the end of the animation by bit signal When the rising edge of the signal is coming the animation will end Repeat repeat the motion of the animation 7 3 Debug and download TH series touch screen support debug download function This function can be used when you are debugging your project in order to save your time Compared with normal download function this function has the following advantages 1 This function only can be used when debugging the project 2 The data transfer speed is faster than normal download save time and cost Click button in th
28. ate Time Add Title 14 Format e Dec M Hex M Float Unsigned i Hove up Tata type tord Bit Length IG 4 Move down Float length 0 0 Delete 3 Save tab Source Path Data Save Control Date Time Object Object 256 4 Control tab Source Path Data Control Date Time S aye Ik Execute status Mo DO DO le Execute result There are 4 items in the title list There are four items in the CSV file 40 10 10 18 40 15 10 30 Ea 45 8 6 25 45 10 8 20 MEN 50 10 8 20 55 12 10 15 Ea 55 14 10 30 EN 55 20 8 20 60 12 10 25 The import registers address Execute status to show if it is in importing state via bit state If the bit is ON TH is importing data Execute result show the import result state via the register state 0 import failed l import target device does not exist 2 the memory is not enough 3 file path error 4 reading writing file failed Execute process show the importing process via register 100 means the importing process is succeed 5 Date time tab Source Path Data Save Control Date Time I Date Time Date format M el 5 i 5 nrn n D Ea Add the date and time in the CSV file Example 2009 10 8 Select the date and time format via the pull down menu Time format H ym ss Example 13 57 04 Example Purpose import the data from object device to TH touch screen select the import dat
29. ate unit Use the unit in appointed screen New Build a new screen Property Screen name author remark delete Delete the current screen Simulate offline Simulate the project in the TH Connect PLC and TH simulate the project in TH online Simulate online Download Download the project in the TH Upload Upload the project from TH to PC Pp ls xa Debug download Debug download 6 Makea simple project In this chapter make a switch to control the PLC output in order to explain how to make TH project NOTE Please make sure the TH type and communication device type it is important for the project download and device communication 6 1 Build a new project 1 Open the touch win version 2 C 2 or above software 2 Click File New or L to build a new project 3 Select the correct TH type and com port device type Select Panel Please select port PLE device Thinget FC Series Thinget VL Series Inverter Mitsubishi FX Series Mitsubishi Q Series Omron CEM COM Series Omron CFACT CS Series Siemens oi 2U0 Series Siemens ST 300 400 Koyo 5 Series Schneider Micro Neza Twido Matsushita FPO FFP1 LS Master E CPU Direct Com Para 19200 5 Even 1 Attr 480x272 65536 colors Setting TH type com port device type 4 Set the com port device communication parameters according to PLC port device Communication Parameter Baudrate Data Bi
30. ct to PSW500 make it the same as the data input button address Object Psw 500 a In this example 1t has not referred to date and time so do not have to set them The screen has been done please see the following picture Data export example Paral Para Paras Farad Faras gt Data input Data export Run the project and you will see the following result Data export example Paral Para Paras Para4 Paras Data export Excel file SJDX csv 1 Paral Parad Paras Parad Parad 2 10 20 30 di Ei 3 Paral Para Paras Parad Farah 25 25 45 KE 66 5 Paral Parad Paras Parad Parab 34 56 Ba TG ag 7 4 2 Import the CSV data The purpose is to import the data from the SD card or U disk to TH register cc I Usa Step1 use function button or function field select import CSV data function Function Field Mode Function Position Function Func Add Modify a ee Function Field Step2 double click import CSV data change the parameters as the following 1 Source path tab Source Path Data Save Control Date Time Device ID the device number of import device e l Dynamic set set the device ID in D register Dynamic set DO Import control control the import process by M wi a coil when M is ON the import process starts Path File CE csv Path File the CSV file name Fix Name Fix name the import data are from the same Add ID After Name source file o Add ID after name se
31. e screen 2 replace Object Bit T Find what Object Hum 1 Replace In Curent Screen ff Whole Screen 3 public unit AN eel Replace Replace with MO Cancel Replace register or coil Find what the object you want to replace Replace with the new object Object num the guantity you want to replace Replace in replace the object in current screen or all the screens select one element in the screen click public unit this element will be added in all the screens 4 private unit After select one element as public unit click private unit to delete this element in other screens 5 2 3 3 View Part Tool Y Standard Status ly Project Y Paint Zoom lv Status Change Y Operate Part Align 5 2 3 4 Part eae Tool Window Text Operate Display Input Keyboard Biar Dynamic Map Window scheme Function Tool Device Display all the tool bars Advance and advance2 is gray color Only when open the advance function of software these items can be used All the items with tick are displayed in the software menu Help The part 1s used to edit the TH project 1t 1s the same as the tool bar in the software A AAA S O GOR BOE fr 5 Moy 1 2 Feo ee G l la MO mE y IA gal a le 1 ds Aly E B B EE 4 4i Inverter Alram Information Picture Display Sample Save 5 2 3 5 Tool Tool Window Line Rectangle Ellipse Fold Hap Option Tool menu i
32. e structure The hardware structure of TH series touch screen includes front and back side Take TH465 M as an example to explain the structure LSB A port Power LED 3 2 Dimension 1 TH465 M exterior dimension 150 0mmx100 0mmx41 0mm mounting dimension 144 0mmx94 0mm 142 0 92 0 144 0 l NN 100 0 94 0 WouchWin ym 2 TH 65 M exterior dimension 205 0mmx151 5mmx48 9mm mounting dimension 192 0mmx138 5mm 136 5 j 192 0 151 5 138 5 ouchWin 3 TH8S65 M exterior dimension 224 4mmx170 8mmx45 5mm mounting dimension 211 4mmx157 8mm 45 5 38 0 209 4 155 8 224 4 3 j 211 4 170 8 157 8
33. e tool bar to debug download the project into your TH 7 4 Data backup based on touchwin V2 C 3 Data backup includes the following contents 1 Data collection and export store the data of TH series HMI into USB device or SD card produce CSV data base file 2 Import CSV data transfer the data of USB device or SD card to TH series HMI About CSV file The CSV file is based on Excel the format is as the following Temperature Pressure Hydraulic Date Time Title ee 2009 8 10 12 10 10 ATS 2009 8 12 12 10 45 Data A SO Le sr 0 2009 8 14 12 10 23 Data Date Time Tobuild CSV file Open Excel input the data as the up format then save as CSV file 7 4 1 Data export Export the data from TH to other device Step1 click function button or function field El select export CSV data and add tt Function Button Function Button Limit Color Position Function Pressing r xport C5V Data Add EELEE When using function button please select pressing or releasing as the trigger condition Releasing r When using function field please select the trigger condition as you need Act Mode f Coil Spring Time Sec Continue 3 First Scan After Down First Scan After Power Step 2 Double click export CSV data it shows the following window This window includes destination import save and date time tab 1 Destination tab D
34. ep the TH away from thrill or strong corrosive gas Never use spray detergent Avoid damage to the screen please do not touch the screen too hard while wiping Caution Please dispose the TH as industry waste 4 Interface and switch 4 1 Introduction TH series touch screen has 1 group of DIP switch and 5 communication ports 4 1 2 3 4 USB A port 5 USB A port2 6 USB B port3 1 DIP switch 2 COMI port 3 COM2 port 42 DIP switch TH has one group of DIP switch at the back side they can set the function of COM port Switch Switch1 Switch2 Switch3 Switch4 Function ON OFF OFF OFF Undefined State OFF ON OFF OFF Forced download mode of COM1 OFF OFF ON OFF Adjust mode of touch area OFF OFF OFF ON Interior check mode not recommend to use 43 COM 1 port TH series touch screen COM1 port has these functions Y Communication function connect with PLC printer frequency inverter used as communication port Y Download function connect with PC used to download data and screens COM 1 port pins definition 9876 Download function Pin Name Meaning 1 NC Unused terminal RXD RS232 receive 3 TXD RS232 send 4 A RS485 signal 5 GND Signal ground 6 NC Unused terminal 7 B RS485 signal 8 NC Unused terminal 9 NC Unused terminal
35. estination Data Save Control Tate Time Device 1D f Device ID set the object device number which you want to export data NH dynamic set can connect the D Path File Wace register with the device ID ES Y Fix Name Re export title Path File the name of the CSV file Name add automatic Fix name the data collected each time will be saved in the same file add number after name Re export title export the title when a collect the data each time Please see the following examples named by date Length Wdth Hight Gy 20 30 40 12 32 41 37 13 Fix name file Length Wdth Hight Gy 20 30 40 12 Length Wdth Hight Gy 32 41 37 13 Fix name and re export title file Name add automatic 1t exports a new file when collect the data each time The new file name will increase automatically For example file 1 is THOO1 csv file 2 will be THOO2 csv Please see the following picture S HSXO00 csv E fag 194001 esv A Microsoft Office a Microsoft Office ai EE dili Add number after name add the number after the file name For example input ry the file name is THOO1 csv Dynamic set set the number in D register For example If DO 20 the file name is THO20 DO 23 the file name is TH023 When add number after name and dynamic set are both selected dynamic set has priority Named by date the file name is added the date When exporting the
36. gister Function button Realize multi functions with this button LL S ja ele Jeje T I Eo Function field Similar to function button but the trigger condition 1s different F Discrete column map Display the data in discrete column map Continue column map Display the data in continue column map Line Draw lines Arc Draw arc Rectangle Draw rectangle Ellipse Draw ellipse Fold polygon Draw fold and polygon Polygon block Similar to container Frame Draw 3D rectangle Map Add jpg or bmp format pictures Move animation make the movement animation of object SE 11111111 o Rotate animation Switch the picture Material library The picture library Date Display the date Clock Display the time Buzzer Control the buzzer by the coil LCD light control Control the background light by the coil Scale Display the value in scale Instrument Display the value in the meter Valve Simulate the state of valve Pipe Simulate the liquid state in the pipe Pump Simulate the pump running Auto wind Simulate the auto wind Motor Simulate the motor running Retort Simulate the retort running in ken is AE Display the inverter alarm information Scroll text Display the text in scroll mode Real time map Display the current value in curve History data map Display the current and history value in curve XY curve Display
37. haracter size Any size and font Touch panel 4 wire resistance mode M emory Screen SMB Construction Cooling method Natural air cooling Exterior dimension 150 0 100 0 41 0mm Mounting dimension 144 0 94 0mm 2 2 TH 65 M tem TH 765 M Input voltage DC20 DC28V Consumption current 250mA Momentary power off Less than 10ms Electrical allowance Withstand voltage AC1000V 10mA 1 minute signal and time Insulated impedance DC500V about 10M signal and time COM1 Support RS 232 RS 485 COM2 Support RS 232 RS422 RS485 Interface USB1 USB A accord with USB2 0 USB2 USB A accord with USB2 0 USB3 USB B accord with USB2 0 Operation temperature OLI 50 C Reserve temperature 20 60 C Environment Environment temperature 20 85 no condensation Withstand oscillation 10 25Hz X Y Z each direction 30 minutes 2G Anti jamming Voltage noise 1000Vp p pulse lus 1 minute Surrounding air No corrosive gas Protection construction IP65 Type 65536 true colors Screen size 7 inch Use life More than 50000 hours 24 hours running when surrounding temperature is 25 C Screen l AA Resolution 800 448 specification Contrast Non adjustable Character Chinese English Korean Japanese Character size Any size and font Touch panel 4 wire resistance mode M emory Scree
38. ies touch screen application examples for the details of TH TH has two USB A ports accord with USB2 0 The functions are show as below Y Duplicate data data import and export transmission speed can be 480Mbps USB A port definition Pins Name M eaning 1 5V 5V voltage signal 2 DATA Data signal 1 3 Y A 3 DATA Data signal 4 5V 5V voltage signal Connect U disk and other USB port devices TH front side TH back side USB A port TH front side USB cable USB mobile BA harddisk USB A 4 6 USB B port TH has one USB B port accord with USB2 0 located in the back side of TH the functions are shown as below y To download the data the speed can up to 480Mbps USB B port definition I 2 M eaning 5V voltage signal Data signal Data signal Ground signal A 3 Please use the USB cable sold in the market when connecting PC with USB B port then click El in the software to download your project in TH TH back side USB cable 5 TouchW In software 5 1 Preparation 1 Software version V2 C and later versions 2 Software source visit Xinje website www xinje com to obtain the software or get from the products CD 3 OS requirements Windows98 2000 X P ME 4 Install steps Click next until show below
39. n 128MB Construction Cooling method Natural air cooling Exterior dimension 205 0 151 5 48 9mm Mounting dimension 192 0 138 5mm 2 3 T H865 M tem TH865 M Input voltage DC20 DC28V Consumption current 260mA Momentary power off Less than 10ms Electrical allowance Withstand voltage AC1000V 10mA 1 minute signal and time Insulated impedance DC500V about 10M signal and time COM1 Support RS 232 RS 485 COM2 Support RS 232 RS422 RS485 Interface USB1 USB A accord with USB2 0 USB2 USB A accord with USB2 0 USB3 USB B accord with USB2 0 Operation temperature OLI 50 C Reserve temperature 20 60 C Environment Environment temperature 20 85 no condensation Withstand oscillation 10 25Hz X Y Z each direction 30 minutes 2G Anti jamming Voltage noise 1000Vp p pulse lus 1 minute Surrounding air No corrosive gas Protection construction IP65 Type 65536 true colors Screen size 8 inch Use life More than 50000 hours 24 hours running when surrounding temperature is 25 C Screen l AA Resolution 800 600 specification Contrast Non adjustable Character Chinese English Korean Japanese Character size Any size and font Touch panel 4 wire resistance mode M emory Screen 128MB Construction Cooling method Natural air cooling Exterior dimension
40. on and data transmission NOTICE Please use TouchW in V2 C and later version to edit your TH project 2 General specification This chapter will introduce the specification of TH series touch screen TH series touch screen contains TH465 M TH765 M TH856 M and THA61 M Series Types TH TH465 M TH765 M TH865 M THA61 M 2 1 T H465 M tem TH465 M Input voltage DC20 DC28V Consumption current 130mA Momentary power off Less than 10ms Electrical allowance Withstand voltage AC1000V 10mA 1 minute signal and time Insulated impedance DC500V about 10M signal and time COM1 Support RS 232 RS 485 COM2 Support RS 232 RS422 RS485 Interface USB1 USB A accord with USB2 0 USB2 USB A accord with USB2 0 USB3 USB B accord with USB2 0 Environment Operation temperature 0 50 C Reserve temperature 20 60 C Environment temperature 20 85 no condensation Withstand oscillation 10 25Hz X Y Z each direction 30 minutes 2G Anti jamming Voltage noise 1000Vp p pulse lus 1 minute Surrounding air No corrosive gas Protection construction IP65 Type 65536 true colors Screen size 4 3 inch Use life More than 50000 hours 24 hours running when surrounding temperature is 25 C Screen aaa Resolution 480 272 specification Contrast Non adjustable Character Chinese English Korean Japanese C
41. r i Data T YPE Word Next change the display tab page data is 5 control is PSB300 Histroy data map Trend Source Display Save Color Font Position Page data 5 show 5 numbers each screen Data Time Page Data 5 Total Data 10 Fick Period 1 Sec Y Contro Control PSB300 control the ON OFF of the PSES00 This Regist was used to control Pick data collection by PSB300 r 1 Total data 10 it can collect 2 screens data Top Bottom Pick period 1 second collect the data every Hone 1 second Change the save tab save the data in the registers start from PSW400 Histroy data map Trend Source Display ave Color Font Position Auto Locate Add a button to control the stop and start of the collection process The button is related to PSB300 PSW300 10 every second PSB300 to control the ON OFF of data collection 2 Data export RB Realize the data export function by function button cio del 1n the tool bar Add 1t on the screen set the button as the following Function Button Function Button Limit Color Position Function Releasing hi Export LSV Data Modi ty Screen Jump set Data Copy Register Delete Import CSV Data Export CSY Data ECEE Fassword Double click the export CSV file to continue the setting Destination Data Save Control Date Time Device ID 1 Dynamic set
42. rate Button Color Position Key Type Password f Touch level Level r f Enter Code Hide Button Normal Change Aspect lf Use Text User Defined Lontani lan Font f Press Save Aspect Emt C Align Left Align Top Align Center Align Middle TEYEISE Align Right Align Bottom 4 select the color tab change the button colors Object Operate Button Color Position kind Color Bert eta E m E a a E m Ley LOLOY Back Color E m m E B LI E More y makethelamp 1 click 2 put it on the screen change the object to Y0 Object Lamp Twinkle Color Position a o Station Device PLC Pat I WirstaNU 7 Station 1 Object Okis Indirect 2 select the lamp tab change the aspect of the lamp Object Lamp Twinkle Color Position Object Lamp Twinkle Color Position Aspect Aspect ti Con EET OFF User Defined amp OFF User Defined W Visibl j Save Aspect W Visibl Save Aspect 2 select the twinkle tab change the lamp state to stop twinkle Object Lamp Twinkle Color Position Status G Stop ON C OFF 3 color and position tab are similar to the button 6 3 simulate offline Do not have to download the project into the TH you can simulate the project in the touchwin software It can save debug time and easy to edit 1 click to enter s mulate offline screen Derek
43. rt CSV data Source Path Data Save Control Date Time Device II 1 Dynamic set UE Device ID 1 T t Ctrl Te NM mu Path File SJDR csv must be the same Path File SIDE esy as the object import file Fix name means importing from the Fix Name same file C Add ID After Name TTT Start ID dynamic appoint PSW500 V Dymanie set 39 start LD 0 W Dynamic set Import tab Source Fath Data Save Control Date Time Register capacity Register mode 2 O Es B Register capacity 10 it means 10 groups of data Title MO Format Register mode line Dec D Hex 1 Delete Float FJ C Unsigned CE Move up Move up Tata type Word Bit length iG 4 Move down aori Float length C Oo Add the title there are 4 rows of data Save tab Source Path Data Save Control Date Tine Object save the data of mobile device Object into TH register starts from PS W400 Ubject Pra y 400 Control tab Source Path Tata Save Control Date Time Execute status PSB300 to show the importing Mw Execute status ESE3OD state Execute result PSW256 to show the importing MW Execute result PEPE result Execute process PSW257 to show the importing MW Execute process process Date time tab Source Fath Data Save Control Date Time Because the import data has time and date select this 1tem jw Date Time Date format YYYY M D
44. rt data No 10 the data table is shown as up 8 TH series touch screen interior objects This chapter will introduce the interior objects of the TH The interior objects contain PSB bit register PSW word register PFW word register 7 NOTICE 1 Only when the advanced function 1s opened the special interior objects can be used 2 PSBO PSB255 PSWO PSW255 PFWO PFW255 are occupied by system Bit register PSB R egister Function Remark PSBO Normally closed coil PSB1 Normally open coil PSB2 Turn on during the first scan period a PSB3 100ms pulse signal 1s pulse signal I minute pulse signal 300ms pulse signal 150ms Communication failure 0 successful 1 failed Succeed to scan the screen once First scan after download First scan after power on Turn off the touch screen Level 1 password flag password 1s opened 0 password is closed Level 2 password flag password 1s opened 0 password is closed Level 3 password flag password is opened 0 password is closed Level 4 password flag password 1s opened 0 password is closed Level 5 password flag password 1s opened 0 password is closed Level 6 password flag password 1s opened 0 password is closed Level 7 password flag password 1s opened 0 password is closed Level 8 password flag password 1s opened 0 pas
45. s the same as the following tool bar xs NOoocwToes Grid size Crid Siri Move Grid set the min pixel when Move Grid Zoom Ratio IS i00 moving the element Grid radio the grid density the smaller Auto Save Ji Z MD Grid Radio the value is the denser the grid is Download Auto save auto save the project at the Com Port coni Down Load All time you set m Download select the project download MM com port TH Download all when you want to upload Display Moris Da ar Hit Key Errors 10 the data please select this item before you download the data into TH Other Display mouse cursor display the mouse Undo 4 Optimistic User Made connected to TH USB port meng 5 2 3 6 Window He lp New build a new window Cascade show all the window in cascade mode New Tile show all the window in tiled mode Cascade Arrange icon arrange all the icons again Tile Arrange Icon 5 2 3 7 Help About TouchWin for TH Edit Show the Touchwin software version and Touch in for TH Edit Tool copyright EL Copyright C 2004 Touchwin Company CANADA 5 2 3 8 Screen Edit the project in the screen Zoom in zoom out the screen S 100 G 3 D oom out HD zoom in Z en show the grid in the screen 5 3 Tool bar Tool bars functions are shown as the following Icon Name Function LI New Build a new project Open Open the file
46. sed to protect the element or screen when input the correct password the button or screen can be used Screen save to protect the LCD After certain time the background light will be off or jump to certain screen Alternation tab Device Font Project Fara Alternation Clock Panel Change Screen Control Station Device PLC Pot Change screen control VirStaNO Station Change the screen ID according to the value of the Object register Object ID xl z Report current screen ID CATA The current screen ID will show in the register Station Device For example change screen control DO 1 TH VirStaNO Station displays No l screen report current screen ID Object DIZI Object D x 0 Clock tab Device Font Froject Fara Alternation Clock Panel M Use ATC Station Device y VirStaNO Station 1 Object Object D Indirect Panel tab Device Font Project Para Alternation Clock Panel Model Description 4504272 65536 colors Set parameter 4096 PSB Num 1024 vis PSW Num 4096 PRM Murn Export the current time to the register For example object DO so the real time will save in DO D5 DO year D1 month D2 day D3 hour D4 minute D5 second Please note the export time 1s hex number The TH type you are using now Set parameter Modify the quantity of PFW and PSW registers Set the PFW register quantity Set the PSB register quantity
47. support BMP JPG format display more lively Support multinational language simple traditional Chinese English Japanese Korean Define the font as you like support underline italic bold shadow and other art words Large picture library with preloading mode no delay for screen motion Switch control dynamic monitor and display data bar map real time trend map time trend map XY trend map discrete continue column map real time alarm history alarm record User defined animation track design User defined data collection and saving function Set user s authority 9 levels password protection Special USB B port for data download make the data transfer faster Simulate online offline upload download data configuration function USB port inside connect flash disk to realize data duplication function speed 480Mbps Communication Two ports communication independently can connect two different devices at the same time Drive the panel printer directly economical and flexible Support free format communication user edits the driver program 1 2 Work flow The work flow of using TH Install edit software Touch Win Edit your project Connect PC and TH power on Do simulate online Connect the PC with TH simulate the action Do simulate offline Simulate the TH action in the software Download project in TH in your PC Connect TH with other devices Realize communicati
48. sword is closed Level 9 password flag password 1s opened 0 password is closed Word register PSW Register Function Remark PSWO Start screen No PSW1 Current screen No PSW20 Screen width read only PSW21 Screen height read only PSW26 PSB amounts read only PSW27 PSW amounts read only PSW28 PFW amounts Occupy PSW28 PSW29 read only PSW30 Year Hex read only PSW31 Month Hex read only PSW32 Day Hex read only PSW33 Hour Hex read only PSW34 Minute Hex read only PSW35 Second Hex read only PSW36 Week Hex read only PSW40 Recipe index PSW54 The device guantity PSW60 COM1 communicate successful time PSW61 COMI communicate failure time PSW62 COM1 communicate overtime time PSW63 COM1 communicate data error time PSW64 COM 1 device version PSW65 COMI device type PSW70 COM2 communicate successful time PSW71 COM2 communicate failure time PSW72 COM2 communicate overtime time PSW73 COM2 communicate data error time PSW74 COM device version PSW75 COM2 device type Word register PFW R egister Function Remark PFW 1 The screen No after power on PFW2 Background color setting PFW 10 Screen saver start time PFW 11 the screen number of screen saver PFW20 COM
49. t C 4900 C 38400 Bits SBits a p 9600 115200 Stop Bit ie 19200 C 187500 i Bit Bits Parity check None C Odd i Even Wait Communication Time 0 MSEL M SendData Vir Station Retry times E Exchange WORD 5 When download port COM1 is not used as communication port please select unuse download port When use COM as com port please select communication device Please select port Download Device nuse Downlad Fort a Thinget AC Series Thinget FC Series 6 Finish the building process Hame Project Author ee oe wo er or mr me he OO Om le a fr a eS a le a a Mag we Remark eee eS Te eT ee ree eT eS Tere Teer eT 7 Click to save the project in the PC 6 2 Make a simple project Make a button on the screen to control the YO output of Xinje XC series PLC Button PLC output YO is ON TH HMI Lam m L Button PLC output YO is OFF Set OFF YO 2 O O Gi PLC COM port Lamp o Makebutton 1 click put the button on the screen Change the object to YO MM Screenl Button Object Operate Button Color Position Station Bevice pyr Bait F VirStaNO 0 Stator 1 Object Z M Indirect 2 select operate tab change the button operate to reverse button Object perate Button Color Position Button Set OH Set OFF Reverse On Instant 3 select button tab change the text to reverse Object Ope
50. t process is end ME If the adjustment process is end please turn off the power of TH then turn off the DIP switch 3 then turn on the power again Now you can use T H normally 7 2 Photo application TH series LCD are 65536 true colors it can make your photo display more vividly This example will make the photo moving in parallel Step1 select the photo Click button in the tool bar to open the material library x Haterial library a Transparent e Mtenkey S ICON of Adobe L Aibo L App 2 Agua 3 AM C Bomb AE 29 Cartoon of 2 Dackart EY Drink EY DVD FY Fish L Funny 23 gHard 23 GLASS 29 Glasz 2 Hardware L Hein L Home ae 3 gt Add File Del File Butterfly jpg ButtertlyO2 jpg ButhertlyOS jpg Buthertl04 jpg Butterfly jpg Buttertly pg Butterfly jpg Buttertly B jpg M m e Butterfly jpg Butterfly 0 jpg Butterfly 1 jpg Butterfly 2 jpg M Add Material Del Material Mm K p E A Select the photo you want then click open button the photo will be added on the screen M Screcnl Step2 ME the motion track Click the button in the tool bar drag your mouse to draw the motion track double click the mouse to finish the drawing Please see the drawing M Screenl Step3 combine the photo with the motion track Drag your mouse to select the photo and the motion track then right click the mouse select group
51. t the import file name by the input value or the value in D register T Syste za Start ID the import data head number Dynamic set can set the head address in D register start III o Dynamic set DU Please see the following picture the import data when select start ID to 5 and 10 2009 8 10 12 10 12 2009 8 10 13 10 12 2009 8 10 14 10 12 a When start ID is 5 import these data 009 8 10 19 10 12 2 10 21 10 12 When start ID 1s 10 import these data 009 8 11 8 10 12 WS eg Lt 009 8 11 10 10 12 009 8 11 11 10 12 009 8 11 12 10 12 When the start ID is O or 1 the import data is the first group 2 Data tab Source Path Data Save Control Date Time Register capacity 100 Register mode E Loop Line Title Data Format i Dec D Hex KUA Delete Float E C Unsigned X Move up Move up Nata type Mord Bit length 6 4 Move down down Float length C T Register capacity the import data group quantity Register mode Loop the data will be stored in the object registers in loop mode so the original data will be covered Line the data import to the object register one after another Add delete move up move down title Add the data title in the list and select the data format type bit length etc Please note the title list items must be the same as the CSV file items Source Path Data Save Control D
52. ta Lo Response data LT TPR i p D EM 4 BT N 19 j t e A ga Frequency inverter si he uh E Other devices L 1 ouchWin as COM I port COMI default mode is communication mode you can realize the communication function by setting the correct communication parameters and device COMI port communication parameter Communication Parameter Ed COMI port communication device Baudrate r Data Bit l 4800 38400 Bits BBits Please select port Download Device A Thinget XC Series f 3600 C 115200 Stop Bit Thinget FC Series 4 yabani seyri i Thinget V5 Series Inverter ie 15200 f 187500 te 1Bit Bits Mitsubishi FX Series LB AA Mitsubishi Series Omron CPM COM Series Parity check Omron CP CI CS Series Siemens S1 Z00 Series None Odd Even Siemens ST 300 400 Koyo 5 Series Wait Schneider Mi cro Heza Twi do Matsushita FPO FPL Communication Time MSEL If SendData VirStation Rekr times 3 4 4COM2 port COM2 port has below functions Y Communicate with industry devices such as PLC inverter meters COM2 port pins definition 9876 M eaning RS422 send RS232 receive RS232 send RS485 Signal ground RS422 send RS485 RS422 receive RS422 receive L 0 UL LO UA A WI N Communicate with PLC TH can communicates with most mainstream PLC TH series
53. ut data export button J Click function button then set as the following Function Button Funetion Button Limit Color Position Function Releasing ALI Set Coil Reset Coil Reverse Coil Copy Coil Screen Jump Set Data Copy Register User Input Open Window Close Window Down Scheme Up Scheme Data Block Transmit Arithmetic Process Code Import CS Data Export CSV Data Export CSV Data Modi Ey Delete IL kek Password Double click the export CSV data to change the parameters Destination tab Destination Data Save Control Date Time Device II LS Device ID 1 is the U disk number Dynamic set T Path File SJDX csv Change the file name to SJDX csv export the data to this file E Fix Hame EE Name add automatic add number after name do named by date Data tab Destination Data Save Control Date Time Register capacity 1 gt Register mode eres i Loop Line Delete Move up Data type C Float E C Unsigned X Bit length 6 Each group of parameters includes 5 values export 1 group parameter each time so the register capacity is Add L paras 1 Format Register mode is line Dec C Hex Add the title make it correspond to the parameters Nord r 4 Move down Float length IC 0 Save tab Destination Data Save Control Date Time Ubica Set the export obje
54. window Enter the information in the space serial number is ThingetTouchWin E Setup TouchYin Vser Information Please enter your information User Hame AHAHA rganization AHAHA Serial Number ThingetTouchfin 5 2 The construction of Touchwin 5 2 1 Screen Double click the Touchwin software build a new project then you can see the following screen CN bar E TouchHin Edit Tool Project Screenl Cox ANA E n X Ef Prohect m Screenl El pa creen Lo Screenl a al Window Y Alarm A ws OH RB ome M Print x Status x Zoom E El LN NOOOCeCOR ss kilidi be TP760 5 T PLC Port Thinget XC Series Download Port Unuse Downlad Port X 18 JE Project bar build delete copy cut operation of the screen and window Screen edit area make the project in this area Menu it includes file edit view tool part window and help Element bar it includes standard part panel operate status zoom draw and align Status bar it includes HMI type PLC port device and download port device 5 2 2 Project bar Project bar contains the operation of screen and window Y Screen operation 1 build a new screen Method 1 click a in the element bar Method 2 right click the screen in the project bar then click insert It shows the following window Screen Xx m ID Name Back Color Message E 2 screen cut copy and delete Se ID the number
55. xporting data Execute result show the export result state via the register state 0 export failed l export target device does not exist 2 the memory is not enough 3 file path error 4 reading writing file failed Execute process show the exporting process via register 100 means the exporting process 1s succeed 5 Date time Destination Data Save Control Date Time Date format rn To add the date in the CSV file Example zin ate L Please select the data format and time format in the pull down menu Time format H Mm 55 Example 9 43 31 EXAMPLE This chapter will introduce the data export examples in loop and line mode lt A gt Data export in loop mode Purpose collect the data via history data map export the data to moveable device and save as CSV file Please see the whole process Save the data in the Collect data registers start y Story from data map PSW400 PSW300 value increase 10 every I second use function field to realize it Produce Collect object is CSV file PSW300 Produce data Data Data export gt gt Process source collection Function filed History data map O Collect data in loop Data change every second Value mode PSW300 PSW300 10 O Data source PSW300 PSW data change process Save object registers 1 second PSW300 0 start from PSW400 2 second PSW300 10 3 second PSW300 20 4 second PSW300 3

Download Pdf Manuals

image

Related Search

Related Contents

Hoover VTC 791NB  LOEWE Art 32    Août 2000 No. 0106 SERVICE MANUAL MANUEL D'ENTRETIEN  APart N-VOLST-BL volume control  株主の皆様へ 臨時株主総会及び普通株主様による種類株主総会招集ご  PDFファイル  2005 Plasma Field Service Guide  af lettre information scolaires  Cátalogo Válvulas de Aguja-Camión  

Copyright © All rights reserved.
Failed to retrieve file