Dark Reader GelHead™
Contents
1. 9 A ee 10 BY BR Green ass EEE ek ae to are aa a UM ee 11 Tips on Using SYBR Green sense 11 Running Buffers for Electrophoresis oooonooocconnnoooooccononoooncnccononccnnnccnnnnnnos 13 Troublesh00fms 2 2 ae een 15 Service AX Parse ee sa 16 Warranty Information ae RR Rei 17 Contact Information ee ie 18 Safety Instructions Keep these instructions available for easy reference by any user of this Dark Reader unit For further assistance contact Clare Chemical Research 18390 Hwy 145 PO Box 180 Dolores CO 81323 Tel 970 882 7499 Fax 970 882 7068 email support clarechemical com web www clarechemical com The GelHead lamp operates at 12 V DC 1 2 A only The AC DC adapter for the lamp in the GelHead is rated for use at 100 240 V 50 60 Hz depending on country Check the voltage rating on the label The lamp in the DG345 uses a low voltage 12 V DC power supply However actual electrophoresis as you already know is typically conducted at 100 V or more This is potentially lethal DO NOT GET THE 2 VOLTAGES CONFUSED The GelHead is designed to be used by individuals who are experienced in using similar devices to fractionate and view stained DNA samples Do not let untrained personnel operate this device As with any electrophoresis device a potentially lethal voltage is present across the gel bed during operation Do not attempt to make contact with electrica
2. the unit by pushing the female connectors onto the male connectors on the gel box This should be done by gripping the amber screen at both ends and guiding the screen onto the gel box using the sides of the gel box as guides to keep the screen parallel to the box as it slides on When attaching and removing the amber screen keep the screen as parallel as possible to the GelHead to avoid putting undue bending stresses on the electrode connectors Switch on the Lamp Insert the input jack of the GelHead wall adapter unit into the socket on the GelHead Plug the GelHead wall adapter unit into a wall socket To turn on the lamp and view DNA bands place the GelHead magnetic switch into the holder on the end wall of the GelHead base Sensitivity is maximized by darkening the room Turn the lamp off by removing the magnetic switch when not viewing the gel to avoid unnecessary heating effects Run the Gel Make sure the power supply to be used to deliver the voltage across the gel is switched off and the voltage setting dial or control is at zero Then attach the black and then the red cables of the amber screen to the appropriate outputs on an electrophoresis DC power supply Switch on the electrophoresis power supply and bring the applied voltage up to the desired value For example using 1 x TAE buffer a voltage of 100 V will adequately separate DNA fragments in less than 60 min The initial current reading on the power supply should
3. 300 pg of dsDNA by eye Running Buffers for Electrophoresis The most common running buffers for agarose gel electrophoresis are 1 x TAE and 0 5 x TBE Another buffer Reliant HS buffer has been recently introduced by Cambrex Inc and is a proprietary formula All these buffers perform well with the GelHead The biggest difference we have found is in the voltage that can be applied to the gel and still achieve a sufficiently low current to avoid excessive heating of the gel In general a higher voltage across the gel will result in a shorter separation time as shown by the data in the table below Buffer Voltage Initial Current Typical Run Time V mA min A gel run for 60 min at 100 V initial current 28 mA using 1 x TAE running buffer with the GelHead lamp switched on intermittently when the gel is actually being viewed will reach a temperature of about 32 C With the lamp on continuously during the electrophoresis run the temperature will rise to approx 39 C Temperatures above 40 oC should be avoided as this can lead to a loss of sensitivity of the fluorescent stain The buffering capacity is an additional factor to consider when choosing a running buffer During electrophoresis the pH of the buffer at the anode will tend to increase and the pH at the cathode will tend to decrease Excessive pH changes can lead to collapse of the gel at the anode and loss of fluorescence at the cathode 1 x TAE has the lowe
4. Clare Chemical Research www clarechemical com Dark Reader GelHead Copyright 1997 2005 by Clare Chemical Research Inc Dark Reader technology is the subject of issued US patents 6198107 and 6512236 as well as US and international patents pending Dark Reader is a trademark of Clare Chemical Research Inc SYBR SYPRO Pro Q TOTO YOYO and Alexa are registered trademarks of Molecular Probes Inc Eugene OR GelStar and Gelbond are registered trademarks of Cambrex Inc Rockland ME Table of Contents Safety IHSEEDCUORS ooo cot cards oho Ge ee 2 Basic Instructions for US oooonooccnnnocccinnocccononcccononcnonnnccononnnnonnno en nennen enne 4 ONCE WE ee 4 Setting Up the GEIHeid nase 5 Eon a title a Eod Coa pui ac aude Rv a di d da db ned 5 Place the COmDs M Hr 5 Prepare the Agarose amp Pour tlie Gel ss ea 5 Add Running BUSES nenn 3 Preparing amples e e he An edad dodi Asa in Ga 6 ACLS CaM MR 6 SYBR Sale a ee ee ib 6 SYBR Green t 6 Ethidium Bromide sans ee 6 KR nnne the Gel AA een 6 Load the Samples ace ee e aeos iss 6 Seattle Top Block a ar re ee 7 Attach the Amber Screens eiio ie 7 Switch on the Lamp nee 7 A a eer ee 7 ACTO SA A AA AAA 8 Photosraphy a a eres esed uet cen el 8 Exeisimne DNA Bags n 8 Clean pono ados esu ead io 8 DNA Denda dd RA 9 a 9 Using GelStar as an In Agarose Stain 9 Migration rates of DNA in the presence of GelStar stain
5. Migration rates of DNA in the presence of GelStar stain GelStar pre stain EtBr post stain GelStar pre stain M gration LE Lance EtBr post stain 1 000 10 000 DNA fragment size bp The amount of DNA loaded onto the GelStar gel shown above is clearly too high This is a direct consequence of the greatly enhanced sensitivity of GelStar versus EtBr for the detection of DNA In practice the amount of DNA loaded onto a GelStar gel can be reduced 5 10 fold Reduced DNA loading levels can result in considerable savings in the cost of expensive reagents Of course if one is attempting to locate minor DNA products in for example a 50 uL PCR reaction then the increased sensitivity of GelStar will allow the visualization of DNA fragments that are simply undetectable with EtBr SYBR Safe Safe is the latest addition to the SYBR stain family and has a number of very attractive benefits Increased safety Data released by Molecular Probes show that SYBR Safe stain is negative in 3 different mammalian cell based assays for genotoxicity and exhibits low mutagenicity compared to EtBr in Ames tests Furthermore SYBR safe has been extensively tested for environmental safety and is NOT classified as hazardous waste under U S Federal regulations Flexible usage SYBR Safe can be used either to stain a gel after running or for the fastest results it can be used as an in agarose stain High stability Safe is stab
6. aining stain can be prepared ahead of time and stored in aliquots for immediate use whenever needed After the gel has set about 20 min depending on the type of agarose used carefully remove the comb This involves slightly wiggling the comb as it is very slowly pulled from the gel To avoid the gel sticking to the comb it can first be treated with Sigmacote from Sigma Add Running Buffer Carefully pour about 20 mL of running buffer directly on top of the agarose and make sure there are no air bubbles trapped in the wells Pour running buffer into the 2 reservoirs until the buffer JUST flows over the ends of the gel tray about 200 mL total Do not overfill For neither SYBR Green SYBR Safe nor GelStar is there a need to add the dye to the running buffer 6 Once running buffer has been added the GelHead should not be moved except to dispose of the running buffer Remember to disconnect the GelHead before moving Preparing Samples In general do not add excessive amounts of tracking dye to the samples as the colorant can obscure fluorescent bands Indeed a dye is not required for tracking purposes the DNA bands will be directly visible as they migrate through the gel We especially recommend using loading buffer from which the xylene cyanol is omitted as this dye tends to migrate in a similar position to many DNA fragments GelStar If the gel contains GelStar then the samples containing loading buffer can simply be loa
7. ater rinsed in distilled water and allowed to dry Do not forget to disconnect the Gelhead before moving it DNA Dyes GelStar Using GelStar as an In Agarose Stain GelStar works very well as a stain if the dye is added to the agarose before electrophoresis The use of GelStar rather than SYBR Green as a pre stain has 2 advantages The sensitivity of DNA detection achieved with GelStar pre stain is much higher than with SYBR Green In fact the sensitivity is almost the same as that achieved with post staining less than 20 pg of dsDNA using a CCD camera and as little as 100 pg can be seen directly by eye The presence of GelStar stain does not significantly affect the migration behavior of DNA samples prepared by typical laboratory protocols such as plasmid preps and PCR see the Figures below Consequently pre staining with GelStar is the recommended technique for the rapid and accurate determination of the sizes of fragments in DNA samples Cambrex has recently introduced a line of pre cast agarose gels containing GelStar stain Reliant HS Gel Systems These gels are very attractive for their simplicity and speed Using a Reliant gel the agarose preparation time is eliminated staining time is eliminated and the gel only need be run until the bands of interest are separated about 15 50 min depending on the complexity of the sample and the running buffer used The total time saved can be over 2 hours start to finish
8. be about 28 34 mA Other running buffers besides Ix TAE can be used including 0 5x TBE and HS Buffer from Cambrex Inc The running buffer should be the same as the buffer used to prepare the agarose Both TBE and HS buffers can be used at higher voltages than TAE and separation times will be correspondingly quicker as described in the attached sheets The actual separation time required will depend on a number of factors besides the voltage applied to the gel including the complexity of the sample the amount of sample and the choice of agarose If the amps meter on your power supply reads zero at this point you do not have a complete electrical circuit Before checking for break points disconnect the power supply leads Here are some possible break points There is insufficient running buffer to cover the ends of the gel tray Add a little more running buffer You have the power supply leads plugged into the other set of outputs on your power supply You forgot to add buffer concentrate to your running buffer and distilled water is a fairly good insulator The amber screen is not properly seated on the GelHead Afterwards After the electrophoresis run is complete turn off the high voltage supply Disconnect the amber screen from the supply before removing the amber screen To remove the amber screen from the GelHead grip the edges of the screen on either side of the electrodes and carefully raise Photography Firs
9. ded onto the gel Because the DNA must enter the gel before becoming fluorescent it will be a couple of minutes after the gel has been started before any fluorescence is visible See the attached sheets for further information on GelStar or visit www clarechemical com gelstar htm SYBR Safe As with a GelStar gel the samples are simply loaded onto into the wells SYBR Safe is not as sensitive as GelStar See the attached sheets for further information on SYBR Safe or visit www clarechemical com safe htm SYBR Green If the DNA is to be pre stained with SYBR Green make a fresh 1 100 dilution of SYBR Green in IXTAE Remember to wear gloves when handling DNA binding stains Add 1 microL of this solution to each 9 microL of DNA sample sample loading buffer Incubate for a few seconds before loading onto the gel See the attached sheets for further information on SYBR Green or visit www clarechemical com green htm Ethidium Bromide The GelHead can also be used to view ethidium bromide EtBr stained DNA if dye is added to the running buffer and agarose Remember to wear gloves when handling DNA binding stains The optimal concentration of ethidium bromide is 0 1 0 2 microg mL We have found that using EtBr at greater dilutions than is typical reduces the background level of fluorescence from the gel leading to better sensitivity The GelHead is not as sensitive as a UV unit for viewing EtBr stained DNA See the attached sheets for furth
10. ed positive electrode There are 2 positions for combs allowing up to 34 samples to be analyzed in a single run Extra comb sets are available Occasionally the comb may stick to the agarose sufficiently when removing the comb to slightly lift the agarose from the bed This can be avoided if the comb washed well before use and treated with Sigmacote Sigma Aldrich SL 2 Prepare the Agarose amp Pour the Gel We typically store agarose in 50 mL screw cap tubes The agarose gel can be slid out of the tubes into a glass beaker to be re liquified Carefully pour melted agarose 50 mL into the gel tray and allow to set Note the gel bed is not sufficiently deep to run a gel more than about 6 mm 0 25 thick Do not overfill the gel tray with agarose The capacity of the tray is 50 mL If the DNA samples are to be visualized using GelStar SYBR Safe or EtBr the stain should be added to the melted agarose BEFORE it is poured into the tray GelStar The agarose should be allowed to cool to around 60 C before adding a 1 10 000 volume of GelStar stain SmicroL of GelStar for 50 mL of agarose Mix well before pouring the gel Remember to wear gloves when handling DNA binding stains SYBR Safe SYBR Safe dye is provided as a ready to use aqueous solution in 0 5 x TBE buffer Because SYBR Safe is stable to both the heating that is involved in preparing molten agarose as well as storage in aqueous solution a batch of agarose cont
11. er information on EtBr or visit www clarechemical com ethidium htm Running the Gel Load the Samples Carefully load the samples onto the gel The 17 well comb creates wells that hold about 15 microL of sample the 10 well about 30 microL and the 6 well about 60 microL Be careful not to puncture the bottom of the well with the pipette tip Samples loaded into the wells at the extreme edges of the gel can result in smiling at higher voltages Seat the Top Block The Top Block is the block of clear plastic about 3 x 5 and 0 75 thick included with the GelHead While the gel is running the Block should be in position across the top of the agarose The Block serves 2 functions by excluding buffer from above the gel all the current will pass through the agarose This leads to faster separation times and sharper bands the Block prevents condensation from forming on the underside of the amber screen so a clear view of the DNA bands is maintained After the samples have been loaded carefully lower the Block into place There are guides on the side walls of the GelHead that facilitate this Start with the Block at an angle of about 20 degrees in contact with the guides at one end of the tray Gently lower the other end of the Block down on top of the agarose in the gel tray Attach the Amber Screen Make sure exterior surfaces are free of liquid including the recessed electrodes Then place the amber screen carefully onto
12. ght contact Clare Chemical Research Warranty Information If you are not satisfied with the Dark Reader GelHead for any reason return it within 30 days for a full refund less shipping and handling The DR GelHead parts and workmanship are guaranteed for year from the date of purchase See details below Please fill out the warranty card and send it back to Clare Chemical To obtain warranty service contact Clare Chemical see p 18 and obtain a Return Form Ship the unit to Clare Chemical postage prepaid together with a completed Form All products returned for warranty service must be carefully repackaged in the original packing materials Clare Chemical Research makes the following limited warranties Clare Chemical Research products are guaranteed to be free of defects in materials and workmanship under normal use for period of 1 year after the date of original purchase During this period Clare Chemical will repair or replace a defective product or part without charge to you The warrant conditions and limitations are set out below The warranty applies only to defect in material or workmanship and does not include normal wear The warranty applies only to defects which occur during normal use and does not extend to damage to products or parts which results from alternation repair modification faulty installation or service by anyone other than Clare Chemical or an authorized representative damage to products or parts cau
13. igrate through the gel using the DR GelHead as shown on the right An electrophoresis run can be halted as soon as the desired DNA bands are separated often within 30 minutes Unlike ethidium bromide which when used as a pre stain must be added to the gel and the running buffer SYBR Green need only be added to the DNA samples This drastically reduces the amount of dye required and virtually eliminates the risk of toxic spills By avoiding the post staining step electrophoresis results are obtained immediately SYBR Green is very economical to use as a pre stain about 0 3 cents per sample 10 e aJ 40 gu Time min Tips on Using SYBR Green 1 For best results when pre staining use a dilution of 1 1 000 of SYBR Green in the DNA sample In the CCR lab we keep a stock of 1 100 SYBR Green in DMSO and add 1 uL of this for every 9 uL of DNA The DMSO does not appear to affect the DNA 2 Run the gel in less than 2 hours During overnight runs the SYBR dye tends to dissociate from the DNA resulting in smeared bands 3 When used with DNA samples generated by typical laboratory procedures such as PCR and plasmid preps the migration of DNA fragments becomes more unpredictable For the rapid and 12 accurate determination of DNA fragment sizes the use of GelStar as a pre stain is recommended 4 Using SYBR Green as a pre stain the sensitivity of detection is not as high as with post staining It is possible to see about
14. l is the lamp If the lamp fails to start seek advice from CCR technical support at the number given above before attempting to open the unit Disconnect the unit from the power supply before attempting to open The GelHead is not designed to be used in the bath Though the unit is designed to be waterproof great caution must be taken when using near liquids Do not allow the wall adapter jack to sit in pools of liquid on the bench top as this may trip the safety features of the wall unit transformer and a replacement will be required In addition salts in the liquid can corrode the jack For the same reasons the contact of any liquids with the 12 V DC socket on the GelHead itself should be avoided Do not place the DG345 containing buffer in an imaging system compartment These imaging systems are not designed for such purposes Switch off the lamp in the GelHead after use to prevent over heating The DG 345 has not been designed to withstand substantial impact so do not drop it on the floor Any impact could affect the structural integrity of the unit causing it to leak Do not forget to disconnect the wall transformer and electrophoresis power supply before attempting to move the GelHead to a different location Though data published by Molecular Probes show that SYBR Green is significantly safer than ethidium bromide it should be remembered that any dye that stains DNA is likely to be hazardous Gloves should be w
15. le for over 6 months in aqueous solution and is also stable to the heating involved in preparing molten agarose Adding SYBR Safe to the agarose before electrophoresis has a number of advantages DNA bands can be directly visualized as they migrate through the gel using the Dark Reader GelHead An electrophoresis run can be halted as soon as the desired DNA bands are separated often within 30 minutes Because SYBR Safe is stable to both the heating that is involved in preparing molten agarose as well as storage in aqueous solution a batch of agarose containing stain can be prepared ahead of time and stored in aliquots for immediate use whenever needed This feature makes SYBR Safe the quickest and most convenient of all the new DNA dyes In the Figure above 0 5 g of agarose was added directly to 50 mL of SYBR Safe stain solution and heated in a microwave for about 1 minute The molten agarose solution was then poured into the bed of a Dark Reader GelHead The gel was loaded with a 2 fold dilution series of a 1 kb DNA ladder ISC BioExpress starting with 100 ng of total DNA and then run at 200 V for 30 minutes using 0 5 x TBE running buffer The DNA detection sensitivity using SYBR Safe is comparable to EtBr using this method about 1 ng by eye and 0 5 ng using a CCD camera SYBR Green Adding SYBR Green directly to DNA samples before electrophoresis has a number of advantages DNA bands can be directly vizualized as they m
16. lly uninsulated areas of the unit such as the running buffer electrodes and connection leads Always use the amber screen to connect to the electrophoresis power supply The screen functions not only to enable viewing of fluorescent samples but also to protect the user from the high voltages required during electrophoresis To prevent damaging the electrodes in the GelHead be sure to attach and remove the amber screen by gripping it at both ends so that the attachment or removal occurs simultaneously at both electrodes Do not stress the electrodes with bending forces Always ensure that the amber screen is disconnected from the power supply before attaching or removing the amber screen from the GelHead Do not overfill the GelHead with buffer The buffer level only needs to be JUST above the ends of the gel tray This requires about 200 mL of buffer assuming the Top Block is in place During electrophoresis do not allow a current of more than 50 mA or a voltage greater than 300 V to pass through the GelHead Measurements show that the Dark Reader GelHead emits less light in the UV light below 400 nm than the standard fluorescent tubes used in most offices and laboratories However the blue light emitted is fairly intense and it is unwise to look at any bright light source for extended periods of time The GelHead is intended only for use with the amber screen The only replaceable component in the GelHead shel
17. ocus focus or using too low an f stop manually With a fixed focus camera increase the f stop Service amp Parts Remember to disconnect the unit from the electric supply before replacing any parts If you have any questions contact Clare Chemical Research The lamp is the only user replaceable part All other problems require that the unit be returned to Clare Chemical Research for servicing Replacement lamps are available from Clare Chemical Research Do not use a lamp with other specifications NOTE if a lamp is broken some of the glass may be a very fine dust DO NOT WIPE THE INSIDE OF THE BOX Wear a pair of gloves and protective glasses when cleaning up broken glass DO NOT TRY TO BLOW THE DUST OUT OF THE BOX A vacuum cleaner is the best way to remove glass fragments Disconnect the unit from the power supply Wear gloves and protective glasses Turn the unit upside down and take out the screws that secure the GelHead to the base Turn the unit right side up hold the GelHead in place Removing the GelHead from the shell reveals 2 gaskets and a white diffuser screen Remove the diffuser screen Remove the lamp from its socket by gently pulling on the lamp Put in a new lamp by gently pressing the lamp into the socket The lamp clicks into place After installing the new lamp reassemble the unit and replace the screws Do not over tighten the screws Only now can you switch the GelHead on If the new lamp fails to li
18. orn when handling solutions or gels containing such dyes Always follow the suppliers instructions for use The glasses are ONLY for viewing in conjunction with DARK READER Products They are NOT safety glasses and do NOT provide eye protection Do not use in conjunction with UV emitting devices Basic Instructions for Use Questions Do not hesitate to contact us Clare Chemical Research 18390 Hwy 145 PO Box 180 Dolores CO 81323 Tel 970 882 7499 Fax 970 882 7068 email support clarechemical com web www clarechemical com Overview Familiarize yourself with the parts of the Dark Reader GelHead as describes on the accompanying Parts Checklist sheet and read the Safety Instructions pages 2 3 of this manual before using your Dark Reader GelHead Setting Up the GelHead Location Place the GelHead on a level surface in a room that can be darkened for the most sensitive detection of DNA fluorescence Ensure that the GelHead especially the gel tray is free of dust particles Some DNA dyes fluoresce brightly upon contact with dust particles Place the Combs Attach the gel comb to the comb support using the screws supplied Ensure that the pegs on the comb support are straight and that they slide easily in and out of the holes in the side walls of the GelHead The combs should be adjusted until they are central across the gel bed and level about 1 mm above the surface of the gel bed Remember DNA migrates towards the r
19. sed by accident abuse or misuse or maintenance mishandling misapplication or use in violation of instruction furnished by us The warranty and remedies set forth above are exclusive and in lieu of all others whether oral or written express or implied Clare Chemical specifically disclaims any and all implied warranties including without limitation warranties of merchantability and fitness for a particular purpose In no event shall Clare Chemical be liable for special incidental consequential or punitive damages including without limitation damage to other property caused by any defect in this product inconvenience loss of goodwill lost profits or revenue loss of use of this product or any associated equipment cost of substitutive equipment downtime costs or claims of any part dealing with purchaser for such damages resulting from the use installation or servicing of this product Nor is Clare Chemical Research liable or responsible for any personal injuries occurring as a result of the use installation or servicing of this product This warranty does not supersede any statutory rights that may be available in certain States or Countries Contact Information Clare Chemical Research 18390 Hwy 145 PO Box 180 Dolores Colorado 81323 USA Toll free 888 292 0356 Tel 970 882 7499 Fax 970 882 7068 email support clarechemical com web www clarechemical com 19 20
20. st buffering capacity and is good for about 75 minutes at 100 V TAE TBE HS Patterns obtained using a DNA molecular weight standard and a variety of running buffers Conditions are listed in the table 1x TAE 40 mM Tris Acetate 1 mM EDTA pH 8 4 0 5 x TBE 44 mM Tris Borate 1 mM EDTA pH 8 4 x HS buffer 10 fold dilution of concentrate 10x HS buffer Cambrex part number 50892 Troubleshooting Problem Joass Soin O No current is flowing through the Electrical circuit is not complete GelHead mA meter on your power because supply reads zero There is insufficient running buffer Add a just enough running buffer to to cover the ends of the gel tray the reservoirs to cover the lip of the gel bed You have the power supply leads Reconnect plugged into the other half of your power supply You forgot to add buffer Difficult to fix Start again concentrate to your running buffer and distilled water is a fairly good insulator The amber screen is not properly Carefully seat the amber screen seated on the GelHead Fluorescence is difficult to see The room needs to be darker Switch off overhead lighting Set up the GelHead away from windows Fluorescent bands are fuzzy and Condensation is forming on the Stop electrophoresis Disconnect the indistinct underside of the amber screen power supply Remove the amber because the Top Block is not in screen and wipe the undersside wi
21. t disconnect the electrophoresis high voltage power supply Any type of imaging equipment such as a digital camera or Polaroid camera can be used to photograph the gel Any non Dark Reader filter attached to the camera should be removed the amber lid of the GelHead provides the optimal color filter Separate DR camera filters are also available www clarechemical com filters htm If necessary a Polaroid camera hood can be placed on the amber screen To achieve focus of the gel using such a hood with a fixed focus camera requires an f stop of 16 22 to achieve a sufficient depth of field Using Polaroid 667 film and a high f stop the exposure time needs to be 20 secs plus With standard digital cameras the DNA bands can be manually focused allowing a lower f stop to be used More information on digital imaging with the Dark Reader is available at www clarechemical com imaging htm Excising DNA Bands This is obviously best done using the glasses Care should be taken to remove the amber screen switch off the power first by gripping at both ends while removing and then pulling the screen off evenly This will ensure that the connectors are not bent If the gel is to be moved from the gel tray a scoop is provided Clean Up Dispose of materials potentially containing DNA stains according to the manufacturers instructions All components of the GelHead that have potentially been in contact with DNA stains should be washed in soap and w
22. th place a tissue Position the Top Block and restart electrophoresis Fluorescent smudges on the gel bed Fluorescent dye is present on the Wipe the surface with a little ethanol surface surface Rinse the gel briefly in water to remove excess dye DNA bands are smeared The gel is overloaded The new DNA Try loading 5 times less sample dyes are much more sensitive than onto the gel EtBr Fluorescent bands in the gel seem to Condensation is forming on the Be sure to use the top block gradually disappear when viewing underside of the amber screen the gel No light from the gel bed The lamp may be broken Replace the lamp see page 16 If this fails to correct the problem contact CCR Photograph of gel does not look as There are several possible causes but See the Photograph Section for more good as when just viewing by eye in general if a photograph does NOT information Pages 8 as well as look as good as when viewed by eye items in this list photographic conditions need optimizing The photo is very dark Not enough light is reaching the Make sure you are using only amber camera screen as a camera filter Increase the exposure time Decrease the f stop The photo is very light Too much light is reaching the Make sure you are using only amber camera screen as a camera filter Decrease exposure time Increase f stop Image is not in focus The usual causes are using auto With a digital camera set the f
Download Pdf Manuals
Related Search
Related Contents
DM1090X - Numark Bloomfield 8780 Coffeemaker User Manual User Manual VX4350 General Purpose Relay Switching Module Westinghouse One-Light Outdoor Wall Lantern with Removable Tail 6686000 Instruction Manual Mazda MX5 - Service Manual 2002-2003 DVXi/ET-xM /-xS DVI-KVM-Extender Type SH7206 CPUボード用 ユニバーサルボード 取扱説明書 BUK7206 B64-3347-00_French r3.Indd 7 inches Color TFT Serials User Manual フクダ電子 グリーン調達基準書 Copyright © All rights reserved.