Home

- Alberici SpA

image

Contents

1. ens DI I 108060 5 Iaa SS To from Servo SA NI E MKII board signal on pin 10 1 HE LZE OU O L pog mm ino 273 ON J1 1x4 pins ccTalk socket to electronic validator SWI UP key J2 1x4 pins ccTalk socket to optional RFID key reader menu scroll value increase 33 2x3 pins Sw2 DOWN key J4 1x3 pins menu scroll value decrease J5 2x5 pins manufacturer use only power supply and credit output signal 2 12Vcc 3 GND 1 credit signal socket to the Servo board Totalizer output at pin 9 out 3 credit signal SW3 OK key J6 1x16 pins display confirm J7 2x3 pins pushbutton A for service line 1 J8 2x3 pins pushbutton B for service line 2 4 2 Servo control board A 10p flat cable connects the Active One control board to the Servo board Power the Servo board by the 3p socket J1 according to the following pattern 230 Vac 24Vac 24Vdc 12Vdc Pin 3 line 230Vac line24 Vac 24Vdc 12Vdc Pin 2 neutral neutral OVdc OVdc Pin 1 GND GND 4 2 1 Connections to start the equipment by relay transmission of power supply EQUIPMENT 1 0000 O en TA a DISABLE Vac L or Vcc As amp CE lt lt IN 2 C2 LINE 2 OUT 1 LINE 2 N C LOUT 1 LINE 2 N O IN 1 C1 LINE 2 WWW myrra com POWER IN 230Vac or 4 24Vac or 24VdC or 12Vdc lt lt POWER IN N ac or dc POWER IN GND ac POWER TO EQUIPMENT To
2. from pulse 230Vac or 24Vac coin validator or 24Vdc or signal on PIN10 12Vdc Service line 1 Pushbutton A from power supply connect one end of service line 1 straight to the relevant actuator i e electrical motor solenoid a s o Connect the other end to pin 1 COM 1 of J2 connector If operation mode is normally open take the switching wire to the 1 actuator from pin 2 N O 1 These wires must be able to sustain 10 Amps current draw If operation mode must be normally closed take the switching wire to the actuator from pin 3 N C 1 If the actuator works by d c take care to connect properly positive and negative poles Service line 2 Pushbutton B from power supply connect one end of service line 2 straight to the relevant actuator 1 e electrical motor solenoid a s o Connect the other end to pin 4 COM 2 of J2 connector If operation mode is normally open take the switching wire to the 2 actuator from pin 5 N O 2 These wires must be able to sustain 10 Amps current draw If operation mode must be normally closed take the switching wire to the actuator from pin 6 N C 2 It is possible to disable coin acceptance in any of the following two ways a Electronically Pins 7 8 of green connector J2 provide any Vdc or Vac line value to pin 7 and respectively OVdc or Neutral Vac to pin 8 b Mechanically move to OFF the dip switches located on the coin acceptor Move them b
3. S p A si riserva il diritto di apportare modifiche alle specifiche tecniche dell apparecchiatura descritta in qualunque momento e senza preavviso nell ambito del perseguimento del miglioramento continuo del proprio prodotto Progettazione e produzione di sistemi di pagamento accessori per videogames e macchine vending ZA Design and manufacture of payment systems accessories for videogames and vending machines Via Ca Bianca 421 Tel 39 051 944 300 http www alberici net 40024 Castel San Pietro Fax 39 051 944 594 Terme BO ITALY info alberici net
4. Ti mebox B ACS 2 line pay for time system with cashless Operator s manual Rev 1 00 User Manual CE Aberici CASH SOLUTIONS Progettazione e produzione di sistemi di pagamento e accessori per macchine Gaming Vending e Car Wash Via C Bianca 421 40024 Tel 39 051 944300 Web www alberici net Castel San Pietro Terme BO Italy Fax 39 051 944594 E mail info alberici net This manual has been prepared with the utmost care Nevertheless it is not possible to assure at any time the exact correspondence of the descriptions to the product features Alberici SpA shall not be held liable by the User for any damage losses or third party claims arising from any uses of the manual or of the product CONTENTS eMail aaa 1 ly Tiles 5 gt lo A a side ida A 5 e SL E A E E 6 4 Electrical connections A aii 6 J Dica 8 b UPS 11 Te Prod Opos a ds 12 Ge Terms GUA rs 12 9 Customer SErViCE srl eee 12 STORICO REVISIONI Revisione n Data Modifica Note 1 00 05 10 12 Creazione ACTIVE ONE ALBERICI Manual Rev 1 00 Page 3 Dear Customer we would like to thank you and congratulate for your choice We trust that you will appreciate the quality and performace of the Alberici TIMEBOX S The data exchanged under MIFARE encryption are then processed through cctalk protocol the serial communication mode that provides security and precision Please read carefully this handbook t
5. ack to ON when you want to resume coin acceptance ACTIVE ONE ALBERICI Manual Rev 1 00 Page 7 Connections to start the equipment by one clean relay switch Ca ata SERIO cha gt i Il N 153 fm www myrra com be To from pulse oooog 20000 coin validator a Signal on PIN10 OUT 2 LINE 2 N C lt 20202 E OUT1 LINE 1 N C gt 0 Ni ciuNET O POWER IN 230Vac or 24Vac or 24VdC or 12Vdc lt POWER IN N ac or dc POWER IN GND ac Service line 1 Pushbutton A from pin 1 COM 1 of the J2 connector take a wire to the actuator of service line 1 If operation mode is normally open take the switching wire to the 1 actuator from pin 2 N O 1 If operation mode must be normally closed take such wire from pin 3 N C 1 Service line 2 Pushbutton B from pin 4 COM 1 of the J2 connector take a wire to the actuator of service line 2 If operation mode is normally open take the switching wire to the 2 actuator from pin 5 N O 2 If operation mode must be normally closed take such wire from pin 6 N C 2 It is possible to disable coin acceptance in any of the following two ways a Electronically b Mechanically 5 Operation Pins 7 8 of green connector J2 provide any Vdc or Vac line value to pin 7 and respectively OVdc or Neutral Vac to pin 8 move to OFF the di
6. ible to inspect the accounts As soon as the key is acknowledged the button lights up green and the display shows the message Entering Total in Service menu XXX XX Press key Total out XXX XX Press key O Reset Partials System n service The owner of the Service key can delete only the Accounts partials The owner of the Master key can erase all Accounts data Accounts data can also be reset by the keys located behind the board see 5 2 ACTIVE ONE ALBERICI Manual Rev 1 00 Page 11 7 Product disposal WARNING DISPOSE OF ACCORDING TO THE GOVERNING LAW IN YOUR COUNTRY This equipment may not be treated as household waste Instead it must be handed over to the applicable collection point for the recycling of electric and electronic equipment By ensuring that this product is dised of correctly you will help to prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact the Dealer where you purchased this product 8 Terms of Guarantee The manufacturer will fix malfunctions arising from production faults in this machine or parts of it within 12 months from the date of sale All communications referring to guarantee repairs or replacements must be accompanied by
7. o obtain the most from your TIMEBOX S Unit Please pay due attention to the following warnings A IMPORTANTE NOTICE REGARDING USER S SAFETY AND PROPER OPERATION OF THIS UNIT A IMPORTANTE NOTICE REGARDING DANGERS ARISING FROM RISK OF ELECTRICAL DISCHARGE AN IMPORTANTE NOTICE REGARDING DANGERS ARISING FROM RISK OF HIGH TEMEPRATURE pe GENERA L NOTE 1 Package content The set includes 1 Timebox ACS unit 2 This manual 3 Requested optional items RFID keys ACR programmer interface This product has been packed with the utmost care If you receive it damaged or incomplete please notify immediately your findings to the Carrier and collect it only under conditional signature 2 Product description 2 1 Intended use The TIMEBOX allows to purchase any of the two available pay for time service Time is purchased by introducing coin s then choosing the desired service by pessing the relevant onboard button keys Price and time for service can be set at any time by entering the programming section of the menu The unit can be installed outdoor provided it is located in a position conveniently sheltered from unfavourable weather conditions 2 2 Available functions Payment and independent activation of 2 service lines Accounts audits on display access to Audits by internal pushbuttons or Master Service Keys Ad libitum Custom configuration of price and time access modifications by internal pushbuttons or Mas
8. p switches located on the coin acceptor Move them back to ON when you want to resume coin acceptance 5 1 Getting started Switch the machine on the display will lit on and will show the following message The machine is ready to operate by the following default set values System in service Line 1 price of service 0 50 pulse length 30 sec Line 2 price of service 0 50 pulse length 30 sec The Timebox B is able to simultaneously control two independent pay for time service lines having different price and time length When introducing one coin or the RFID key the corresponding credit will be displayed If such amount is enough to activate at least one of the two service lines this one or both of them shall be proposed and the relevant pushbutton light will change from blue to green colour When pressing the button for service line A or service line B the display will show briefly paid amount and total time then the relevant relay will switch on and remain on for the set time The display will show the progress of the count down and the pushbutton will be blinking until end of service time If it has been introduced a larger amount than the price for the service the proportionally larger activation time shall be displayed and activated EQUIP MENT 1 5 2 Modifying the Menu data 5 2 1 Menu configuration The unit provides a full interactive and user friendly menu acce
9. ss it by the button OK then scroll it by DOWN or UP ACTIVE ONE Promo ani SET UP SHOW CCTALK PERIPHERALS TTT DOWN EXIT MENU di Vista da dietro xk Peripheral units Coin accepto Operation ei Initialize N set up set up set up iS Cashless ok DA oc See Section 5 2 2 Promotion I message to appear I Me the display when Only if ACS is NM in stand by condition present Change Language Change wa PIN code PIN Y needed ok UN Reset to default PIN code configuration needed ACTIVE ONE ALBERICI Manual Rev 1 00 Page 9 5 2 2 Setting operation parameters To change price and length of the services use the buttons behind the board or any of the Management Keys ACTIVE ONE ACCOUNTS Promo Set Up Peripheral units Set up Service Parameters It is now possible to increase the price by the button UP Price serv 1 or decrease it by the button DOWN 0 50 Each stroke changes the value by 0 05 pressing Price serv 1 Price serv 1 Price serv 1 for longer than 4 seconds 0 45 0 50 0 55 makes the change run faster Pulse length 1 It is now possible to increase the pulse length by the button UP Lia a 30s or decrease it by the button DOWN Each stroke changes the value by 0 01 seconda 10 Pulse length 1 Pulse length 1 Pulse length 1 ms pressing for longer 0 293 0 30 s 0 31 s than 4 seconds makes the change run fas
10. ter Price serv 2 0 50 To set the second service line repeat the above Or else press until the Exit option shows up Exit Press OK Jto display SHOW CCTALK PERIPHERALS EXIT System MENU in service 10 6 Operation 6 1 Activating the service Keys with sufficient credit Introducing an RFID key charged with sufficient credit or as many coins as to reach the requested amount the button blue light turns to green indicating that the system is ready The display shows the credit contained in the key Credit 30 00 and prompts to Press button to start service Press the button once the trigger pulse is sent to the control board while the button flashes yellow At the ssaame time the display will show for 5 seconds the credit remaining in the stick Credit 29 50 Introduced 0 50 Each pressure of the button sends one signal to the control board and one credit is taken off from the amount in the key Keys with sufficient credit Introducing an RFID key charged with insufficient credit the following message shows up Credit 00 00 Credit 00 00 changing to Insuff Credit Insert credit In this case the key can be recharged by inserting coins in the coin acceptor until the desired value and then pressing the button The display shows Saving data followed by Credit xx xx 6 2 Control of Accounts By the Service key or the Maste key it is poss
11. ter Key 2 3 General Data Size 125 mm x 116mm x 390 mm Weigh 5 50 Kgs Power supply 230V o 24Vca o 24Vcc o 12Vcc must be specified when placing the order Highest current at relay contacts 8 Amps Working temperature 10 C 50 C humidity 10 70 non condensed Installation Wall mount indoor or outdoor sheltered against water sprays direct sunlight Components Coin acceptor AL66V cctalk Control board Active One Interface service board Alberici Servo MKII Cashless Reader ACS Alberici RFID MIFARE reader and charger 24 Caution 1 Comply with the instructions in this manual 2 Switch power off before any maintenance operation 3 Use only within the recommended temperature humidity range 4 Do not expose the machine to direct sun light 5 Do not favour contact with dusts or chemical moisture or sprays water or other liquids 8 Wipe clean by a dry piece of cloth or slightly wet with alcohol 9 Do not use thinners or organic solvents ACTIVE ONE ALBERICI Manual Rev 1 00 Page 5 75 0 1273 160 0 390 0 170 0 127 0 4 Electrical connections ZN Electrical cables must not be powered during installation The TIMEBOX B is available for 4 different power supplies 230Vac 24Vac 24Vdc 12Vdc When placing your orders please specify which presetting you need the interface Servo board shall be prepared accordingly 4 1 Active One control board z DTA I om
12. the product serial number and the copy of the sale invoice To obtain your guarantee repair please send the part to the Dealer where you purchased the machine together with the following documents copy of the sale invoice delivery note stating returned for guarantee repair detailed report of the problem found and the circumstances in which it occurs Before sending the product please get in touch with your Dealer or with Alberici S p a 39 051 944300 very malfunctions can be fixed via a simple phone call saving you costs and time Alberici S p a will verify that warranty is applicable i e that problem is not caused by transport damages damages from incorrect installation or wrong configuration installation in premises or areas not complying with the prescribed safety requirements intentional or unwilled tampering wrong or careless use or maintenance non compliance with precautions prescribed see Chapter 4 Caution natural disasters vandalisms intentional or unintentional damage Guarantee is considered automatically expired if outer and inner labels are missing Transport costs of repaired products are at the Customer s charge 9 Customer Service Alberici S p a will be pleased to offer all the necessary information on use ordinary maintenance and technical service Please call 39 051 944300 and specify if your request concerns information on use or technical support La Alberici

Download Pdf Manuals

image

Related Search

Related Contents

  概要 - 素形材センター  PostScriptファイルの作成 QuarkXPress 3.3J    HOBO Pro v2 User`s Manual (Part # U23-00x)  E1/E20 Emulator Additional Document for User`s Manual: High  取扱説明書(PDF: 0.2 MB)  第170期株主レポート  User Manual  vopos - desmon  

Copyright © All rights reserved.
Failed to retrieve file