1.   Immediately flush out fraction with the magnetically labeled  cells by firmly applying the plunger supplied with the column    MS  1 mL LS  5 mL    A Note  To increase the purity of the magnetically labeled fraction  it can be passed  over a new  freshly prepared column     Magnetic separation with XS Columns   For instructions on the column assembly and the separation  refer to  the  XS Column data sheet     Depletion with LD Columns    1  Place LD Column in the magnetic field of a suitable MACS  Separator  see  LD Column data sheet       2  Prepare column by rinsing with 2 mL of buffer   3  Apply cell suspension onto the column     4  Collect unlabeled cells which pass through and wash column  with 2x1 mL of buffer  Collect total effluent  This is the unlabeled  cell fraction     Depletion with CS Columns    1  Assemble CS Column and place it in the magnetic field of a  suitable MACS Separator  see  CS Column data sheet       2  Prepare column by filling and rinsing with 60 ml of buffer  Attach  a 22G flow resistor to the 3 way stopcock of the assembled  column  see  CS Column data sheet       3  Apply cell suspension onto the column    4  Collect unlabeled cells which pass through and wash column  with 30 mL buffer from top  Collect total effluent  This is the  unlabeled cell fraction    Depletion with D Columns   For instructions on column assembly and separation  refer to the    D Column data sheet     Magnetic separation with autoMACS    Separator    A Refer to the au
2.  to non specific cell labeling     6   Optional  Add staining antibodies  e g  add 10 uL of CD45 FITC     130 091 609   and incubate for 5 minutes at 4   8   C     7  Wash cells by adding 1 2 mL of buffer per 10    cells and centrifuge  at 300xg for 10 minutes  Pipette off supernatant completely     8  Resuspend up to 10   cells in 500 uL of buffer   A Note  For higher cell numbers  scale up buffer volume accordingly     A Note  For depletion with LD columns  resuspend cell pellet in 500 uL of buffer  for up to 1 25x108 cells     9  Proceed to magnetic separation  2 3      n    2 3 Magnetic separation    A Choose an appropriate MACS Column and MACS Separator  according to the number of total cells and the number of CD45  cells   see table in section 1 3      Magnetic separation with MS or LS Columns    1  Place column in the magnetic field of a suitable MACS Separator   see  Column data sheets       Order No  130 052 301    2  Prepare column by rinsing with appropriate amount of buffer   MS  500 uL LS  3 mL    3  Apply cell suspension onto the column     4  Collect unlabeled cells which pass through and wash column  with appropriate amount of buffer  Perform washing steps by  adding buffer three times  each time once the column reservoir  is empty    MS  3x500 uL LS  3x3 mL  Collect total effluent  This is the unlabeled cell fraction     5  Remove column from the separator and place it on a suitable  collection tube     6  Pipette appropriate amount of buffer onto the column 
3. S0 vZ0 000 0rL       Miltenyi Biotec    Index  1  Description  1 1 Principle of MACS    separation  1 2 Background and product applications  1 3 Reagent and instrument requirements  2  Protocol    2 1 Sample preparation  2 2 Magnetic labeling    2 3 Magnetic separation  3  Example of a separation using CD45 MicroBeads    4  References    1  Description    Components 2 mL CD45 MicroBeads  mouse   MicroBeads conjugated to monoclonal anti   mouse CD45  Ly 5  isotype  rat IgG2b  clone   30F11 1  antibody    Size For 2x10  total cells  up to 200 separations     Product format CD45 MicroBeads are supplied as a suspension    containing stabilizer and 0 05  sodium azide     Store protected from light at 4 8   C  Do not freeze   The expiration date is indicated on the vial label     Storage    1 1 Principle of MACS  separation    First  the CD45  cells are magnetically labeled with CD45 MicroBeads   Then  the cell suspension is loaded onto a MACS    Column which is  placed in the magnetic field of a MACS Separator  The magnetically  labeled CD45  cells are retained on the column  The unlabeled cells  run through and this cell fraction is depleted of CD45  cells  After  removal of the column from the magnetic field  the magnetically  retained CD45  cells can be eluted as the positively selected cell  fraction     1 2 Background and product applications    CD45 MicroBeads are used for the positive selection or depletion  of leukocytes from lymphoid and non lymphoid tissues  The CD45  an
4. e  K  Eckert  HG  Baum  G  Zeller  WJ  Fruehauf  S  2000   Quantitative assessment of retroviral transfer of the human multidrug resistance 1  gene to human mobilized peripheral blood progenitor cells engrafted in nonobese  diabetic severe combined immunodeficient mice  Blood 95  1237 1248     Order No  130 052 301    Warnings    Reagents contain sodium azide  Under acidic conditions sodium azide yields hydrazoic  acid  which is extremely toxic  Azide compounds should be diluted with running water  before discarding  These precautions are recommended to avoid deposits in plumbing  where explosive conditions may develop     Warranty   The products sold hereunder are warranted only to be free from defects in workmanship  and material at the time of delivery to the customer  MILTENYI BIOTEC GmbH makes  no warranty or representation  either expressed or implied  with respect to the fitness  of a product for a particular purpose  There are no warranties  expressed or implied   which extend beyond the technical specifications of the products  MILTENYI BIOTEC  GmbH    s liability is limited to either replacement of the products or refund of the  purchase price  MILTENYI BIOTEC GmbH is not liable for any property damage   personal injury or economic loss caused by the product     MACS    is a registered trademark of Miltenyi Biotec GmbH        This MACS    product is for in vitro research use only  and not for diagnostic or therapeutic procedures     page 3 3    
5. eral Protocols  in the User Manuals or visit www miltenyibiotec   com     A Dead cells may bind non specifically to MACS MicroBeads  In case of high    numbers of dead cells we recommend to remove dead cells by density gradient  centrifugation or using the Dead Cell Removal Kit    130 090 101      an    b 2 2 Magnetic labeling    A Work fast  keep the cells cold  and use pre cooled solutions  This  will prevent capping of antibodies on the cell surface and non specific  cell labeling     A Volumes for magnetic labeling given below are for up to 10    total  cells  When working with fewer than 10    cells  use the same volumes  as indicated  When working with higher cell numbers  scale up all  reagent volumes and total volumes accordingly  e g  for 2x10    total  cells  use twice the volume of all indicated reagent volumes and total  volumes      A For optimal performance it is important to obtain a single   cell suspension before magnetic separation  Pass cells through  30 um nylon mesh  Pre Separation Filters   130 041 407  to remove  cell clumps which may clog the column     1  Determine cell number     2  Centrifuge at 300xg for 10 minutes  Pipette off supernatant  completely     3  Resuspend cell pellet in 90 uL of buffer per 107 total cells   4  Add 10 uL of CD45 MicroBeads per 10    total cells     5  Mix well and incubate for 15 minutes at 4 8   C     A Note  Working on ice may require increased incubation times  Higher temperatures  and or longer incubation times lead
6. ing  the autoMACS Separator                 Column max number max number Separator  of labeled cells of total cells   Positive selection   MS 107 2x108 MiniMACS  OctoMACS   VarioMACS  SuperMACS   LS 108 2x10  MidiMACS  QuadroMACS   VarioMACS  SuperMACS   XS 10   2x10  SuperMACS   Depletion   LD 108 5x108 MidiMACS  QuadroMACS   VarioMACS  SuperMACS   CS 2x108 VarioMACS  SuperMACS   D 10  SuperMACS   Positive selection or depletion   autoMACS 2x108 4x10  autoM ACS          A Note  Column adapters are required to insert certain columns into VarioMACS     Separator or SuperMACS    Separator  For details  see MACS Separator data sheets        Optional  Fluorochrome conjugated CD45 antibodies  e g   CD45 FITC    130 091 609   CD45 PE    130 091 610  or  CD45 APC    130 091 811         Optional  PI  propidium iodide  or 7 AAD for the flow  cytometric exclusion of dead cells        Optional  Pre Separation Filters    130 041 407  to remove cell  clumps        Miltenyi Biotec GmbH   Friedrich Ebert StraRe 68  51429 Bergisch Gladbach  Germany  Phone  49 2204 8306 0  Fax  49 2204 85197  macs miltenyibiotec de   www  miltenyibiotec com    Miltenyi Biotec Inc    2303 Lindbergh Street  Auburn  CA 95602  USA   Phone 800 FOR MACS   1 530 888 8871  Fax  1 530 888 8925  macs miltenyibiotec com    page 1 3    S0  7Z0 000 0rL    2  Protocol  2 1 Sample preparation    Prepare a single cell suspension from lymphoid organs  non   lymphoid tissue or peripheral blood using standard methods  see   Gen
7. tigen is expressed on all cells of hematopoietic origin except  erythrocytes and platelets     Examples of applications      Positive selection or depletion of CD45  leukocytes from spleen   lymph nodes  thymus  bone marrow  peripheral blood  body fluids  or non hematopoietic tissue       CD45 MicroBeads were used in combination with Anti Ter 119  MicroBeads    130 049 901  for depletion of mouse leukocytes  to enrich human cells from bone marrow of chimeric mice      CD45 MicroBeads    Mouse    Order No  130 052 301    1 3 Reagent and instrument requirements       Buffer  degassed   Prepare a solution containing PBS  phosphate  buffered saline  pH 7 2  0 5  BSA and 2 mM EDTA by diluting  MACS BSA Stock Solution    130 091 376  1 20 in autoMACS     Rinsing Solution    130 091 222   Keep buffer cold  4 8   C    A Note  EDTA can be replaced by other supplements such as anticoagulant citrate  dextrose formula A  ACD A  or citrate phosphate dextrose  CPD   BSA can be    replaced by other proteins such as mouse serum albumin  mouse serum or fetal calf  serum  Buffers or media containing Ca   or Mg   are not recommended for use       MACS Columns and MACS Separators  CD45  cells can be  enriched by using MS  LS or XS Columns  positive selection    CD45 MicroBeads can be used for depletion of CD45  cells on  LD  CS or D Columns  Cells which strongly express the CD45  antigen can also be depleted using MS  LS or XS Columns   Positive selection or depletion can also be performed by us
8. toMACS    User Manual for instructions on how to  use the autoMACS Separator     1  Prepare and prime autoMACS Separator        This MACS    product is for in vitro research use only  and not for diagnostic or therapeutic procedures     page 2 3    S0 7Z0 000 0rL    2  Place tube containing the magnetically labeled cells in the    autoMACS Separator  For a standard separation  choose  following separation programs    Positive selection   Possel    Depletion   Depletes     A Note  Program choice depends on the isolation strategy  the strength of magnetic  labeling and the frequency of magnetically labeled cells  For details see autoMACS  User Manual   autoMACS Cell Separation Programs      3  When using the program  Possel   collect positive fraction   outlet port  pos1    This is the purified CD45  cell fraction     When using the program  Depletes     collect unlabeled fraction   outlet port  neg1    This is the CD45  cell fraction     3  Example of a separation using CD45 MicroBeads    CD45  cells were isolated from a mouse spleen cell suspension  using CD45 MicroBeads  a MiniMACS    Separator and an MS  Column  The cells are fluorescently stained with CD45 FITC     130 091 609   Cell debris and dead cells were excluded from the  analysis based on scatter signals and PI fluorescence     Before separation    CD45 FITC       Forward scatter    CD45  cells CD45  cells    CD45 FITC  CD45 FITC       Forward scatter Forward scatter    4  References    1  SchiedImeier  B  Ktihlick
    