1. REME R CAUTION Please read and understand these instructions before installing or operating this unit Caution Never open unit when in use Always disconnect main power before replacing fuse Remember to always replace with the exact same type fuse 1 Year Limited Warranty Eliminator Lighting warranty is valid from the date of purchase Our 1 year limited warranty covers manufacturing defects only Serial number place of purchase with dated valid receipt must be submitted at time of service Eliminator Lighting warranty does not cover items or parts prone to wear and tear lamps fuses brushes and belts Eliminator Lighting warranty is only valid with in the United States Eliminator Los Angeles CA SPECIFICATIONS Model LEDs Weight Size Fuse Supply Voltage Working Position Duty Cycle DMX Channels Colors Warranty Operating Instructions Electro Panel 192 192 64 Red 64 Green amp 64 Blue 4 6lbs 2 1kgs 7 12 H x 12 41 W x 4 5 D 2 Amp 120V Any Safe position None 6 DMX Channel Modes 1 2 3 4 6 or 7 DMX Channels Multiple Colors 1 Year The Electro Panel 192 has been tested at the factory there is no assembly required The unit is ready to be plugged into a power out let This unit is a 7 channel DMX intelligent LED par can It can be run as a stand alone static unit DMX controlled unit or in a Master Slave configuration While in
2. Press the UP or DOWN buttons to select UN to switch on the LED or UFF to switch off the LED 3 Press ENTER to confirm and exit USA This function will reverse the display 180 1 Tap the either the MENU button until i LSP is displayed press ENTER 2 Tap the UP button until FL 3 Press ENTER the display will show UN UFF P is displayed 4 Press the UP button to select UN to activate this function or UFF to deactivate this function 5 Press ENTER to confirm F i nS With this function you can display the running time of the unit 1 Tap the either the MENU button until FHRS is displayed press ENTER 2 The display shows the running time of the unit Press MENU to exit VER Use this function to display the Software version of the unit 1 Tap the either the MENU button until VER is displayed press ENTER 2 The display will show the software version Eliminator Los Angeles CA www EliminatorLighting com DMX CONFIGURATION 1 CH 2 CH 3 CH 4 CH 6 CH 7 CH MODE MODE MODE MO DE uN EM FUNCTION COLOR MACROS gt COLOR MACROS Dimmer 3 RED SREEN BLUE RED GREEN BLUE DIMMER aa 6 6 RED GREEN BLUES OLOR MACH 3 5 TROBE DIMMER RED GREEN BLUE MARCOS PROGRAMS s PE ED S TROBE DIM MER 6Channels 8 oss tos ore Pess as 255 100 Fast Strobe NNN 88 98 MAGENTA A Taran Slow ogram 1 Strobe y o Lor Channel
3. Stand Alone or a Master Slave configuration you can run the auto mode For stand alone mode and Master Slave configuration settings see other side www EliminatorLighting com HILILIR DMX Address Setting 1 Tap the either the MENU UP or DOWN buttons until ALOR is displayed press ENTER 2 P will now be displayed and flashing Press the UP or DOWN buttons to find your desired address Press ENTER to set your desired DMX address Li There are 6 DMX Channel modes to choose from this will let you switch and select your DMX Channel mode You can choose from either 1 2 3 4 6 or 7 DMX Channels Please see the last page of the DMX values and traits for each DMX Channel Mode 1 Tap the either the MENU button until LAND is displayed press ENTER 2 Tap the UP or DOWN buttons to scroll through the different DMX Channel modes Once you have found your desired DMX Channel mode press ENTER to confim and exit nim er LIIL This will let you set unit as a master or slave in a master slave configuration 1 Tap the either the MENU button until SLND is displayed press ENTER ASIR SL or SL 2 will be displayed 2 Tap the UP or DOWN buttons until your desired setting is displayed press ENTER to confim and exit 5 SH NL i in this mode you can choose and run one of 11 preprogrammed shows 1 Tap the either the MENU button until SANO is displayed press ENTER 2 Ta
4. p the UP or DOWN buttons to scroll through 11 preprogrammed shows 3 Select your desired show by pressing the ENTER button to confirm and exit in this mode you can set the brightness intensity of the fixture 1 Tap the either the MENU button until UIT is displayed press ENTER 2 Tap the UP or DOWN buttons to adjust the brightness 0 255 A setting of O will not produce any light output 3 Select your desired intensity by pressing the ENTER button to confirm and exit 1 Tap the either the MENU button until STRU is displayed press ENTER 2 Tap the UP or DOWN buttons to adjust the stobe rate 0 255 A setting of O will deactivate the strobe feature INU in this mode you can activate and set the strobe rate 3 Select your desired strobe rate by pressing the ENTER button to confirm and exit DL Blackout or Stand by mode 1 Tap the either the MENU button until SLND is displayed press ENTER Either Yes or No will be displayed Eliminator Los Angeles CA www EliminatorLighting com 2 To activate Blackout tap the UP or DOWN buttons until Yes is displayed press ENTER to confim and exit The fixture will now be in Blackout mode To deactivate Blackout mode select No and press Enter LEL With this function you can switch the lamp on or off via the control board 1 Tap the either the MENU button until LED is displayed press ENTER 2 The display will show either UN or UFF
5. s a et ms mw ous ote eur sass oss os Joao as sel ia i Fast eet Strobe NAN Slow Strobe Eliminator Los Angeles CA www EliminatorLighting com